1
|
Salvatici M, Sommese C, Corsi Romanelli MM, Drago L. Review of Literature and Recommended Procedures for Management of Unusual Cases of False Positive Troponin Tests. Int J Mol Sci 2025; 26:1045. [PMID: 39940813 PMCID: PMC11817740 DOI: 10.3390/ijms26031045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2025] [Revised: 01/22/2025] [Accepted: 01/24/2025] [Indexed: 02/16/2025] Open
Abstract
Heterophile antibodies are immunoglobulins produced by the immune system in response to exposure to animal and bacterial antigens, blood transfusions, autoimmune disorders, hematologic malignancies, dialysis, and pregnancy. Recently, these antibodies have garnered significant attention due to their impact on the accuracy of laboratory test results. Heterophile antibodies can bind not only to specific antigens but also to those from different species, including the antibodies used in laboratory tests. This cross-reactivity with foreign proteins is the basis for their interference in immunological assays, such as those measuring cardiospecific troponins (cTn). This manuscript reviews the literature on cases of heterophile antibody interference in troponin testing and proposes an algorithm for identifying such interference when clinical discrepancies arise. Recognizing and addressing heterophile antibody interference is crucial, particularly for tests like those for troponins, which are key biomarkers in the diagnosis and management of emergency and intensive care patients. The literature emphasizes the need for accurate procedures to distinguish true cardiac damage from false positives, thereby preventing unnecessary additional tests and hospitalizations.
Collapse
Affiliation(s)
- Michela Salvatici
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20099 Milan, Italy
| | - Carmen Sommese
- Medical Direction, IRCCS MultiMedica, 20099 Milan, Italy;
| | - Massimiliano M. Corsi Romanelli
- Department of Biomedical Sciences for Health, University of Milan, 20122 Milan, Italy;
- Department of Clinical and Experimental Pathology, IRCCS Istituto Auxologico Italiano, 20095 Milan, Italy
| | - Lorenzo Drago
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20099 Milan, Italy
- Clinical Microbiology and Microbiome Laboratory, Department of Biomedical Sciences for Health, University of Milan, 20122 Milan, Italy
| |
Collapse
|
2
|
Salvatici M, Gaimarri M, Rispoli F, Bianchi B, Sansico DF, Matteucci E, Antonelli A, Bandera F, Drago L. Troponin Test, Not Only a Number: An Unusual Case of False Positive. Int J Mol Sci 2024; 25:11937. [PMID: 39596007 PMCID: PMC11593478 DOI: 10.3390/ijms252211937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 11/04/2024] [Accepted: 11/05/2024] [Indexed: 11/28/2024] Open
Abstract
Heterophile antibodies, which can arise from infections, autoimmune disorders, or exposure to animal antigens, can interfere with immunoassays. These antibodies can cross-react with the test reagents used in troponin assays, causing a false elevation in troponin levels. The paper describes a case of a 37-year-old male drug abuser admitted to the emergency room with chest pain. A series of troponin measurements performed using different assays gave discrepant results. Only thanks to the use of Scantibodies HBT tubes, which remove heterophile antibodies, was it possible to make a correct diagnosis of troponin negativity. In conclusion, a correct laboratory/clinical approach to the identification of heterophile antibody interference is essential for accurate troponin testing in order to avoid false positive results. Implementing neutralizing tests can significantly improve the reliability of these diagnostic assays, ensuring better patient outcome.
Collapse
Affiliation(s)
- Michela Salvatici
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Monica Gaimarri
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Francesca Rispoli
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Barbara Bianchi
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Delia Francesca Sansico
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Eleonora Matteucci
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
| | - Andrea Antonelli
- Coronary Unit, IRCCS MultiMedica, 20099 Milan, Italy; (A.A.); (F.B.)
| | - Francesco Bandera
- Coronary Unit, IRCCS MultiMedica, 20099 Milan, Italy; (A.A.); (F.B.)
- Department of Biomedical Sciences for Health, University of Milan, 20133 Milan, Italy
| | - Lorenzo Drago
- UOC Laboratory of Clinical Medicine with Specialized Areas, IRCCS MultiMedica Hospital, 20138 Milan, Italy; (M.S.); (M.G.); (F.R.); (B.B.); (D.F.S.); (E.M.)
- Clinical Microbiology and Microbiome Laboratory, Department of Biomedical Sciences for Health, University of Milan, 20133 Milan, Italy
| |
Collapse
|
3
|
Antos A, Topolska-Woś A, Woś M, Mitura A, Sarzyńska P, Lipiński T, Kurylcio A, Ziółkowski P, Świtalska M, Tkaczuk-Włach J, Gamian A, Polkowski WP, Staniszewska M. The unique monoclonal antibodies and immunochemical assay for comprehensive determination of the cell-bound and soluble HER2 in different biological samples. Sci Rep 2024; 14:3978. [PMID: 38368450 PMCID: PMC10874376 DOI: 10.1038/s41598-024-54590-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Accepted: 02/14/2024] [Indexed: 02/19/2024] Open
Abstract
The expression of the HER2 (human epidermal growth factor receptor 2) protein in cancer cells is a well-established cancer marker used for diagnostic and therapeutic purposes in modern treatment protocols, especially in breast cancer. The gold-standard immunohistochemical diagnostic methods with the specific anti-HER2 antibodies are utilized in the clinic to measure expression level of the membrane-bound receptor. However, a soluble extracellular domain (ECD) of HER2 is released to the extracellular matrix, thus the blood assays for HER2 measurements present an attractive way for HER2 level determination. There is a need for accurate and validated assays that can be used to correlate the concentration of the circulating HER2 protein with disease clinical manifestations. Here we describe two monoclonal antibodies binding HER2 with a unique sequence of the complementarity-determining regions that recognize HER2 ECD. Development and validation of the sandwich enzyme-linked immunosorbent assay (ELISA) for quantification of the soluble HER2 in a variety of biological samples is also presented. The assay provides HER2 quantitation within a concentrations range from 1.56 to 100 ng/ml with sensitivity at the level of 0.5 ng/ml that meets the expectations for measurements of HER2 in the blood and tumor tissue samples. The method presents satisfactory intra- and inter-assay precision and accuracy for immunochemical quantification of biomarkers in biological samples. The utility of the generated monoclonal anti-HER2 antibodies has been confirmed for use in the precise measurement of HER2 (both cell-bound and soluble) in several types of biological material, including serum, solid tumor tissue, and cell culture medium. Additionally, the developed immunochemical tools have a potential for HER2 detection, not only in a wide range of sample types but also independently of the sample storage/pre-processing, allowing for comprehensive HER2 analysis in tissue (IHC), cultured cells (immunofluorescence) and blood (ELISA).
Collapse
Affiliation(s)
- Aleksandra Antos
- SDS Optic, EcoTech Complex, Block A, Głęboka 39, 20-612, Lublin, Poland
| | | | - Marcin Woś
- SDS Optic, EcoTech Complex, Block A, Głęboka 39, 20-612, Lublin, Poland
| | - Agata Mitura
- SDS Optic, EcoTech Complex, Block A, Głęboka 39, 20-612, Lublin, Poland
| | - Paulina Sarzyńska
- SDS Optic, EcoTech Complex, Block A, Głęboka 39, 20-612, Lublin, Poland
| | - Tomasz Lipiński
- Lukasiewicz Research Network - PORT Polish Center for Technology Development, Stabłowicka 147, 54-066, Wrocław, Poland
| | - Andrzej Kurylcio
- Department of Surgical Oncology, Medical University of Lublin, Radziwiłłowska 13, 20-080, Lublin, Poland
| | - Piotr Ziółkowski
- Department of Pathomorphology, Wrocław Medical University, Marcinkowskiego 1, 50-368, Wrocław, Poland
| | - Marta Świtalska
- Department of Experimental Oncology, Hirszfeld Institute of Immunology and Experimental Therapy, Polish Academy of Sciences, Weigla 12, 53-114, Wrocław, Poland
| | - Joanna Tkaczuk-Włach
- Chair of Obstetrics and Gynecology, Faculty of Health Sciences, Medical University of Lublin, Staszica 4/6, 20-081, Lublin, Poland
| | - Andrzej Gamian
- Laboratory of Medical Microbiology, Hirszfeld Institute of Immunology and Experimental Therapy, Polish Academy of Sciences, Weigla 12, 53-114, Wrocław, Poland
| | - Wojciech P Polkowski
- Department of Surgical Oncology, Medical University of Lublin, Radziwiłłowska 13, 20-080, Lublin, Poland
| | - Magdalena Staniszewska
- SDS Optic, EcoTech Complex, Block A, Głęboka 39, 20-612, Lublin, Poland.
- Faculty of Medicine, The John Paul II Catholic University of Lublin, Konstantynów 1J, 20-708, Lublin, Poland.
| |
Collapse
|
4
|
Nayeemuddin SN, Panigrahi A, Bhattacharjee R, Chowdhury S. Heterophilic Interference of Rheumatoid Factor in TSH Immunometric Assay: A Cross-Sectional Observational Study. Indian J Endocrinol Metab 2024; 28:29-34. [PMID: 38533277 PMCID: PMC10962763 DOI: 10.4103/ijem.ijem_99_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/10/2023] [Accepted: 04/26/2023] [Indexed: 03/28/2024] Open
Abstract
Introduction Considering the inherent vulnerability of immunoassays for heterophilic interference and the potential of Rheumatoid Factor (RF) to act as a heterophile-like antibody, we conducted this study to investigate if RF leads to any such heterophilic interference in seropositive rheumatoid arthritis (RA) patients. The study was done on the TSH assay as it is a noncompetitive, double antibody sandwich assay, which is known to be vulnerable to heterophilic interference. Methods In this cross-sectional observational study, eighty-four consecutive newly diagnosed RF-positive RA patients underwent TSH, Free T4, and anti-TPO estimation using the chemiluminescence technique (CLIA) on Siemens Immulite 1000 platform. The samples were screened for TSH interference using four methods: 1) analysis on a different platform, 2) assessment of linearity using doubling dilutions, 3) polyethylene glycol (PEG) precipitation, and 4) addition of a commercial blocker. Results Ten samples had a loss of linearity on serial dilution, indicating potential interference. After heterophile blocker treatment, five cases exhibited interference. One patient had diagnostic interpretation discordance on the second platform. No sample on PEG precipitation suggested the influence of antibodies. It is worth noting that even in cases where interference was suspected, the clinical interpretation was largely unaffected by the correction of TSH values based on mean dilution or measurement after heterophile blocker treatment. Conclusion RF can cause heterophilic interference in TSH immunoassays used commercially. However, in most cases, this interference does not affect clinical decision-making.
Collapse
Affiliation(s)
- Shaikh N. Nayeemuddin
- Department of Endocrinology, ESIC Medical College and Hospital, Hyderabad, Telangana, India
| | - Akash Panigrahi
- Department of General Medicine, Tata Main Hospital, Jamshedpur, Jharkhand, India
| | - Rana Bhattacharjee
- Department of Endocrinology, Medical College, Kolkata, West Bengal, India
| | - Subhankar Chowdhury
- Department of Endocrinology and Metabolism, Institute of Post Graduate Medical Education and Research, Kolkata, West Bengal, India
| |
Collapse
|
5
|
Galior KD, Ladwig PM, Snyder MR, Algeciras-Schimnich A, Bornhorst JA, Block DR, Baumann NA, Willrich MAV. Lack of observed interference by therapeutic monoclonal antibodies in select commonly utilized immunoassays. Clin Biochem 2023; 121-122:110685. [PMID: 37972806 DOI: 10.1016/j.clinbiochem.2023.110685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/17/2023] [Accepted: 11/07/2023] [Indexed: 11/19/2023]
Abstract
BACKGROUND Therapeutic monoclonal antibodies (tmabs) have been hypothesized to interfere with immunoassay measurements, although studies investigating this potential new class of interference are lacking. This study evaluated the effects of tmabs used in cancers ipilimumab (Bristol Myers Squibb), nivolumab (Bristol Myers Squibb), pembrolizumab (Merck) and autoimmune disorders adalimumab (AbbVie), infliximab (Janssen) and vedolizumab (Takeda) in common immunoassays used in the clinical laboratory. METHODS Residual sera from 10 randomly chosen patients were split into two tubes and spiked with same volume (approximately 5 % final volume) of either saline (control) or 6 tmabs (final concentration of 100 μg/mL each). Concentrations from sixteen analytes in 19 different assays were assessed: TSH (Roche and Beckman), free thyroxine (Roche and Siemens), cortisol (Beckman), Cancer Antigens (CA): CA19-9 (Beckman), CA15-3 (Roche), CA125 (Roche), and CA27.29 (Siemens), carcinoembryonic antigen (Beckman), alpha-fetoprotein (Beckman), thyroglobulin (Beckman) and thyroglobulin antibodies (Beckman), thyroid peroxidase antibody (Beckman), beta-human chorionic gonadotropin (Roche and Beckman), total prostate-specific antigen (Roche), parathyroid hormone (Roche) and antinuclear antibodies IgG (Werfen). The tmab spiked residual sera were compared with matched saline spiked sera and percent error was assessed against allowable total error defined from biological variation or CLIA limits. RESULTS None of the tested immunoassays were affected by the presence of the tmabs, in samples within or outside assay reference intervals. The median % error among all immunoassays ranged between -2.0% (for TSH) to 2.7% (for TPO Ab assay). CONCLUSION These findings demonstrate no detectable tmab interference for the assessed immunoassays using spiked preparations of the tmabs in residual human sera. The findings are limited to the tmabs and immunoassays studied here.
Collapse
Affiliation(s)
- Kornelia D Galior
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA; Department of Pathology and Laboratory Medicine, Emory University, Atlanta, GA, USA.
| | - Paula M Ladwig
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | - Melissa R Snyder
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | | | - Joshua A Bornhorst
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | - Darci R Block
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | - Nikola A Baumann
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
6
|
Zuraeva ZT, Nikankina LV, Kolesnikova GS, Abdulhabirova FM, Beltsevich DG, Malysheva NM, Mikheenkov AA. [Calcitonin measurement in fine-needle washout fluids in detecting medullary thyroid cancer]. PROBLEMY ENDOKRINOLOGII 2023; 69:9-15. [PMID: 37448242 DOI: 10.14341/probl13236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 07/15/2023]
Abstract
BACKGROUND The diagnostic value of calcitonin measurement in fine-needle aspiration biopsy wash-out fluid is a promising tool in the diagnosis of medullary thyroid cancer. AIMS We assessed the potential usefulness and the diagnostic significance of Ct-FNAB alone in comparison with cytology in the diagnosis and localization of primary or metastatic MTC. MATERIALS AND METHODS For this purpose, we retrospectively examined data from 67 patients with suspicious thyroid nodules and/or lymph nodes who ultimately underwent surgical treatment at the Endocrinology Research Centre in 2015-2020. The primary endpoint of the study was to evaluate the diagnostic accuracy of Ct-FNAB when compared to cytological examination. The secondary endpoint was to determine the optimal diagnostic level for use in clinical practice. RESULTS The obtained results showed that high Ct-FNAB concentrations were present in all histologically proven MTC, either in thyroid gland (sensitivity 92.5%, specificity 100%) or neck masses (sensitivity 88.5%, specificity 100%). The optimal diagnostic threshold for Ct-FNAB values from thyroid nodes was > 122 pg/ml, from lymph nodes >35.8 pg/ml. CONCLUSIONS Our findings suggest that Ct-FNAB is a highly reliable diagnostic procedure to identify primary and recurrent/metastatic MTC. The actual relevance of this technique in the management of MTC needs further longitudinal studies in a larger number of patients.
Collapse
|
7
|
OUP accepted manuscript. J Appl Lab Med 2022; 7:989-994. [DOI: 10.1093/jalm/jfac029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 03/29/2022] [Indexed: 11/13/2022]
|
8
|
An Interesting Case of Isolated False-Reactive Hepatitis B Surface Antigen. Case Reports Hepatol 2021; 2021:9928098. [PMID: 34336313 PMCID: PMC8313323 DOI: 10.1155/2021/9928098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2021] [Revised: 06/21/2021] [Accepted: 07/13/2021] [Indexed: 12/02/2022] Open
Abstract
The standard serologic markers used to diagnose hepatitis B infection include hepatitis B surface antigen (HBsAg), hepatitis B surface antibody (anti-HBs), total hepatitis B core antibody (anti-HBc), and IgM antibody to hepatitis B core antigen (IgM anti-HBc). Different markers or combinations of markers are used to identify different phases of HBV infection and determine whether a patient has acute or chronic infection or immunity due to prior infection or vaccination or is seronegative and susceptible to future infection. Isolated HBsAg seropositivity is a peculiar serological pattern that requires investigation. Herein, we present a case of an asymptomatic female without a history of liver disease or evident risk factors for hepatitis, who underwent screening for infectious disease prior to resection of basal cell carcinoma involving her eyelid. The patient's laboratory testing showed positivity for HBsAg and the HIV 1/2 screen. To investigate, we performed serial dilutions, utilized heterophilicantibody blocking tubes, and repeated analysis using a different commercial assay (Abbott Architect i2000), all in support of a false-positive result attributed to a heterophilic antibody. Hence, we demonstrate that heterophilic antibody interference can result in isolated HBsAg positivity and recommend considering this form of interference in the differential where there is low clinical suspicion for viral infection.
Collapse
|
9
|
Simultaneous determination of 24,25- and 25,26-dihydroxyvitamin D3 in serum samples with liquid-chromatography mass spectrometry - A useful tool for the assessment of vitamin D metabolism. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1158:122394. [PMID: 33091679 DOI: 10.1016/j.jchromb.2020.122394] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Revised: 09/06/2020] [Accepted: 09/23/2020] [Indexed: 12/17/2022]
Abstract
Vitamin D status is typically assessed by the measurement of 25-hydroxyvitamin D (25(OH)D). However, in selected patient groups the sole determination of 25(OH)D has been proven insufficient for this purpose. The simultaneous measurement of additional vitamin D metabolites may provide useful information for a better evaluation of the vitamin D status. Therefore, we developed and validated a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of 25(OH)D3, 25(OH)D2, 24,25(OH)2D3 and additionally 25,26(OH)2D3, which was identified with a synthesized pure substance. Pure and deuterated substances were used to prepare calibrators and internal standards for all target metabolites. Pre-analytical sample preparation comprised protein precipitation followed by liquid-liquid-extraction and derivatization with 4-Phenyl-1,2,4-triazole-3,5-dione (PTAD) using 50 µL sample volume. Samples were analyzed on an Agilent HPLC 1260 system equipped with a silica-based Kinetex® 5 µm F5 100 Å core-shell column (150 × 4.6 mm) coupled to a Sciex 4500 mass spectrometer. For all four metabolites, limit of detection (LoD) and limit of quantification (LoQ) ranged from 0.3 to 1.5 nmol/L and 1.0 to 3.1 nmol/L, respectively. Recovery varied between 76.1 % and 84.3 %. Intra- and inter-assay imprecision were <8.6 % and <11.5 %, respectively. The analysis of external and internal quality control samples showed good accuracy for 25(OH)D3, 25(OH)D2, 24(R),25(OH)2D3 and 25,26(OH)2D3. Method comparison studies with human samples that were also analyzed with two other LC-MS/MS methods showed close agreement. Finally, the present method has been shown capable of identifying patients with 24-hydroxylase deficiency, which proves its clinical utility.
Collapse
|
10
|
Li D, Wu J, Liu Z, Qiu L, Zhang Y. Novel circulating protein biomarkers for thyroid cancer determined through data-independent acquisition mass spectrometry. PeerJ 2020; 8:e9507. [PMID: 32704452 PMCID: PMC7346861 DOI: 10.7717/peerj.9507] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Accepted: 06/17/2020] [Indexed: 12/02/2022] Open
Abstract
Background Distinguishing between different types of thyroid cancers (TC) remains challenging in clinical laboratories. As different tumor types require different clinical interventions, it is necessary to establish new methods for accurate diagnosis of TC. Methods Proteomic analysis of the human serum was performed through data-independent acquisition mass spectrometry for 29 patients with TC (stages I–IV): 13 cases of papillary TC (PTC), 10 cases of medullary TC (MTC), and six cases follicular TC (FTC). In addition, 15 patients with benign thyroid nodules (TNs) and 10 healthy controls (HCs) were included in this study. Subsequently, 17 differentially expressed proteins were identified in 291 patients with TC, including 247 with PTC, 38 with MTC, and six with FTC, and 69 patients with benign TNs and 176 with HC, using enzyme-linked immunosorbent assays. Results In total, 517 proteins were detected in the serum samples using an Orbitrap Q-Exactive-plus mass spectrometer. The amyloid beta A4 protein, apolipoprotein A-IV, gelsolin, contactin-1, gamma-glutamyl hydrolase, and complement factor H-related protein 1 (CFHR1) were selected for further analysis. The median serum CFHR1 levels were significantly higher in the MTC and FTC groups than in the PTC and control groups (P < 0.001). CFHR1 exhibited higher diagnostic performance in distinguishing patients with MTC from those with PTC (P < 0.001), with a sensitivity of 100.0%, specificity of 85.08%, area under the curve of 0.93, and detection cut-off of 0.92 ng/mL. Conclusion CFHR1 may serve as a novel biomarker to distinguish PTC from MTC with high sensitivity and specificity.
Collapse
Affiliation(s)
- Dandan Li
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Science, Beijing, China
| | - Jie Wu
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Science, Beijing, China
| | - Zhongjuan Liu
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Science, Beijing, China
| | - Ling Qiu
- Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Science, Beijing, China
| | - Yimin Zhang
- Department of Clinical Laboratory, Zhejiang Cancer Hospital, Hangzhou, Zhejiang, China
| |
Collapse
|
11
|
Diamandis P, Prassas I, Diamandis EP. Antibody tests for COVID-19: drawing attention to the importance of analytical specificity. Clin Chem Lab Med 2020; 58:1144-1145. [PMID: 32386187 DOI: 10.1515/cclm-2020-0554] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 04/22/2020] [Indexed: 11/15/2022]
Affiliation(s)
- Phedias Diamandis
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada
| | - Ioannis Prassas
- Department of Pathology and Laboratory Medicine, Mount Sinai Hospital, Toronto, Canada
| | - Eleftherios P Diamandis
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Canada.,Department of Pathology and Laboratory Medicine, Mount Sinai Hospital, Toronto, Canada.,Department of Clinical Biochemistry, University Health Network, Toronto, Canada.,Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, 60 Murray St [Box 32], Flr 6 - Rm L6-201-1, Toronto, ON, M5T 3L9, Canada
| |
Collapse
|
12
|
Wang HY, Chen CH, Shi S, Chung CR, Wen YH, Wu MH, Lebowitz MS, Zhou J, Lu JJ. Improving Multi-Tumor Biomarker Health Check-up Tests with Machine Learning Algorithms. Cancers (Basel) 2020; 12:E1442. [PMID: 32492934 PMCID: PMC7352838 DOI: 10.3390/cancers12061442] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 05/22/2020] [Accepted: 05/29/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Tumor markers are used to screen tens of millions of individuals worldwide at annual health check-ups, especially in East Asia. Machine learning (ML)-based algorithms that improve the diagnostic accuracy and clinical utility of these tests can have substantial impact leading to the early diagnosis of cancer. METHODS ML-based algorithms, including a cancer screening algorithm and a secondary organ of origin algorithm, were developed and validated using a large real world dataset (RWD) from asymptomatic individuals undergoing routine cancer screening at a Taiwanese medical center between May 2001 and April 2015. External validation was performed using data from the same period from a separate medical center. The data set included tumor marker values, age, and gender from 27,938 individuals, including 342 subsequently confirmed cancer cases. RESULTS Separate gender-specific cancer screening algorithms were developed. For men, a logistic regression-based algorithm outperformed single-marker and other ML-based algorithms, with a mean area under the receiver operating characteristic curve (AUROC) of 0.7654 in internal and 0.8736 in external cross validation. For women, a random forest-based algorithm attained a mean AUROC of 0.6665 in internal and 0.6938 in external cross validation. The median time to cancer diagnosis (TTD) in men was 451.5, 204.5, and 28 days for the mild, moderate, and high-risk groups, respectively; for women, the median TTD was 229, 132, and 125 days for the mild, moderate, and high-risk groups. A second algorithm was developed to predict the most likely affected organ systems for at-risk individuals. The algorithm yielded 0.8120 sensitivity and 0.6490 specificity for men, and 0.8170 sensitivity and 0.6750 specificity for women. CONCLUSIONS ML-derived algorithms, trained and validated by using a RWD, can significantly improve tumor marker-based screening for multiple types of early stage cancers, suggest the tissue of origin, and provide guidance for patient follow-up.
Collapse
Affiliation(s)
- Hsin-Yao Wang
- Department of Laboratory Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33305, Taiwan; (H.-Y.W.); (C.-H.C.); (Y.-H.W.)
- 20/20 GeneSystems, Inc., Rockville, MD 20850, USA; (S.S.); (M.S.L.)
- Program in Biomedical Engineering, Chang Gung University, Taoyuan City 33301, Taiwan
| | - Chun-Hsien Chen
- Department of Laboratory Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33305, Taiwan; (H.-Y.W.); (C.-H.C.); (Y.-H.W.)
- Department of Information Management, Chang Gung University, Taoyuan City 33301, Taiwan
| | - Steve Shi
- 20/20 GeneSystems, Inc., Rockville, MD 20850, USA; (S.S.); (M.S.L.)
| | - Chia-Ru Chung
- Department of Computer Science and Information Engineering, National Central University, Taoyuan City 32001, Taiwan;
| | - Ying-Hao Wen
- Department of Laboratory Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33305, Taiwan; (H.-Y.W.); (C.-H.C.); (Y.-H.W.)
| | - Min-Hsien Wu
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyuan City 33301, Taiwan;
| | | | - Jiming Zhou
- 20/20 GeneSystems, Inc., Rockville, MD 20850, USA; (S.S.); (M.S.L.)
| | - Jang-Jih Lu
- Department of Laboratory Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan City 33305, Taiwan; (H.-Y.W.); (C.-H.C.); (Y.-H.W.)
- 20/20 GeneSystems, Inc., Rockville, MD 20850, USA; (S.S.); (M.S.L.)
- Department of Medical Biotechnology and Laboratory Science, Chang Gung University, Taoyuan City 33301, Taiwan
- Department of Medicine, College of Medicine, Chang Gung University, Taoyuan City 33301, Taiwan
| |
Collapse
|
13
|
Jara-Aguirre JC, Baumann NA, Block DR, Algeciras-Schimnich A. Human chorionic gonadotropin suspected heterophile interference investigations in immunoassays: a recommended approach. Clin Chem Lab Med 2020; 57:1192-1196. [PMID: 30753153 DOI: 10.1515/cclm-2018-1142] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Accepted: 01/18/2019] [Indexed: 11/15/2022]
Abstract
Background Heterophile antibody (HAb) interferences in immunoassays can cause falsely elevated hCG concentrations leading to incorrect diagnosis and treatments options. When results are not consistent with the clinical findings, hCG HAb interference investigation may be requested by the physician. A retrospective evaluation of the frequency of HAb interference was performed among cases of physician-requested investigations and the effectiveness of commercially available blocking reagents to detect HAb interference in two immunoassay systems was evaluated. Methods One hundred and thirteen physician requests for hCG HAb investigation from 2008 to 2017 were reviewed. The primary method used to measure hCG was the Beckman Coulter Access Total βhCG (2008-2010) and the Roche Elecsys HCG+β (2014-2017). HAb investigation included measurement by two immunoassays before and after treatment of samples with heterophile blocking reagents and serial dilution studies. Results Five cases of HAb and HAb-like interference were identified. The interference frequency was 6.7% for the Beckman assay and 2.9% for the Roche assay. The presence of HAb was detected using heterophile blocking reagents and an alternative method in three cases. The other two cases were detected due to discrepant results with an alternative method and non-linear serial dilutions (HAb-like). Conclusions HAb interference was observed in the Beckman and the Roche assays. The heterophile blocking reagents failed to detect 40% of interference cases. Blocking reagents should not solely be used for these investigations. Multiple strategies including the use of serial dilutions and using an alternative platform are critical when troubleshooting interferences in hCG immunoassays.
Collapse
Affiliation(s)
- Jose C Jara-Aguirre
- Mayo Clinic, Department of Laboratory Medicine and Pathology, Rochester, MN, USA
| | - Nikola A Baumann
- Mayo Clinic, Department of Laboratory Medicine and Pathology, Rochester, MN, USA
| | - Darci R Block
- Mayo Clinic, Department of Laboratory Medicine and Pathology, Rochester, MN, USA
| | | |
Collapse
|
14
|
Verbeek HHG, de Groot JWB, Sluiter WJ, Muller Kobold AC, van den Heuvel ER, Plukker JTM, Links TP. Calcitonin testing for detection of medullary thyroid cancer in people with thyroid nodules. Cochrane Database Syst Rev 2020; 3:CD010159. [PMID: 32176812 PMCID: PMC7075519 DOI: 10.1002/14651858.cd010159.pub2] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
BACKGROUND Thyroid nodules are very common in general medical practice, but rarely turn out to be a medullary thyroid carcinoma (MTC). Calcitonin is a sensitive tumour marker for the detection of MTC (basal calcitonin). Sometimes a stimulation test is used to improve specificity (stimulated calcitonin). Although the European Thyroid Association's guideline advocates calcitonin determination in people with thyroid nodules, the role of routine calcitonin testing in individuals with thyroid nodules is still questionable. OBJECTIVES The objective of this review was to determine the diagnostic accuracy of basal and/or stimulated calcitonin as a triage or add-on test for detection of MTC in people with thyroid nodules. SEARCH METHODS We searched CENTRAL, MEDLINE, Embase and Web of Science from inception to June 2018. SELECTION CRITERIA We included all retrospective and prospective cohort studies in which all participants with thyroid nodules had undergone determination of basal calcitonin levels (and stimulated calcitonin, if performed). DATA COLLECTION AND ANALYSIS Two review authors independently scanned all retrieved records. We extracted data using a standard data extraction form. We assessed risk of bias and applicability using the QUADAS-2 tool. Using the hierarchical summary receiver operating characteristic (HSROC) model, we estimated summary curves across different thresholds and also obtained summary estimates of sensitivity and specificity at a common threshold when possible. MAIN RESULTS In 16 studies, we identified 72,368 participants with nodular thyroid disease in whom routinely calcitonin testing was performed. All included studies performed the calcitonin test as a triage test. Median prevalence of MTC was 0.32%. Sensitivity in these studies ranged between 83% and 100% and specificity ranged between 94% and 100%. An important limitation in 15 of the 16 studies (94%) was the absence of adequate reference standards and follow-up in calcitonin-negative participants. This resulted in a high risk of bias with regard to flow and timing in the methodological quality assessment. At the median specificity of 96.6% from the included studies, the estimated sensitivity (95% confidence interval (CI)) from the summary curve was 99.7% ( 68.8% to 100%). For the median prevalence of MTC of 0.23%, the positive predictive value (PPV) for basal calcitonin testing at a threshold of 10 pg/mL was 7.7% (4.9% to 12.1%). Summary estimates of sensitivity and specificity for the threshold of 10 pg/mL of basal calcitonin testing was 100% (95% CI 99.7 to 100) and 97.2% (95% CI 95.9 to 98.6), respectively. For combined basal and stimulated calcitonin testing, sensitivity ranged between 82% and 100% with specificity between 99% and 100%. The median specificity was 99.8% with an estimated sensitivity of 98.8% (95% CI 65.8 to 100) . AUTHORS' CONCLUSIONS Both basal and combined basal and stimulated calcitonin testing have a high sensitivity and specificity. However, this may be an overestimation due to high risk of bias in the use and choice of reference standard The value of routine testing in patients with thyroid nodules remains questionable, due to the low prevalence, which results in a low PPV of basal calcitonin testing. Whether routine calcitonin testing improves prognosis in MTC patients remains unclear.
Collapse
Affiliation(s)
- Hans HG Verbeek
- University of Groningen, University Medical Center GroningenDepartment of EndocrinologyHanzeplein 1GroningenNetherlands9713 GZ
| | - Jan Willem B de Groot
- Isala Oncological CenterDepartment of Internal MedicinePO Box 10400ZwolleNetherlands8000 GK
| | - Wim J Sluiter
- University of Groningen, University Medical Center GroningenDepartment of Internal MedicineHanzeplein 1GroningenNetherlands9700 RB
| | - Anneke C Muller Kobold
- University of Groningen, University Medical Center GroningenLaboratory MedicineHanzeplein 1GroningenNetherlands9700 RB
| | - Edwin R van den Heuvel
- Eindhoven University of TechnologyDepartment of Mathematics and Computer ScienceP.O. Box 513EindhovenNetherlands5600 MB
| | - John TM Plukker
- University Medical Center GroningenOnocological SurgeryHanzeplein 1GroningenNetherlands9713 GZ
| | - Thera P Links
- University of Groningen, University Medical Center GroningenDepartment of EndocrinologyHanzeplein 1GroningenNetherlands9713 GZ
| | | |
Collapse
|
15
|
Affiliation(s)
- James L. Januzzi
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts
- Baim Institute for Clinical Research, Boston, Massachusetts
| | - Cian P. McCarthy
- Division of Cardiology, Massachusetts General Hospital, Boston, Massachusetts
| |
Collapse
|
16
|
Costante G, Meringolo D. Calcitonin as a biomarker of C cell disease: recent achievements and current challenges. Endocrine 2020; 67:273-280. [PMID: 31925733 DOI: 10.1007/s12020-019-02183-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Accepted: 12/29/2019] [Indexed: 12/19/2022]
Abstract
The neoplastic proliferation of parafollicular thyroid cells (C cells) may occur as either medullary thyroid carcinoma (MTC) or C cell hyperplasia (CCH) and is generically defined C cell disease. Since Calcitonin (CT) expression is fully maintained in neoplastic C cells, this hormone represents a sensitive marker for neoplasia of C cell derivation such as CCH and MTC. Serum CT levels display a high prognostic value and accurate estimation of tumor burden, allowing early detection of persistence/relapse and representing a reliable marker of response to treatment. Indeed, elevated CT levels can occur in other non-C cell-related conditions (i.e., other malignancies, systemic diseases, and pharmacological treatments). Moreover, some de-differentiated, more aggressive MTCs may present disproportionately low-circulating CT levels, as compared with tumor burden. During the postsurgical follow-up of MTC patients, CT levels usually parallel tumor progression and their increase unambiguously announces persistence/relapse. In this respect, CT Doubling Time (DT) has been proposed as prognostic factor of potential use for the identification of more aggressive MTCs. The present review will summarize the novel achievements on the clinical suitability of CT as a biomarker in clinical oncology and will point the attention to the most recent results concerning the usefulness and the possible drawbacks of circulating CT as a surrogate marker for the identification of rapidly progressing MTC patients, such as those candidate to targeted therapies. The emerging role of circulating CT as a parameter of response to local and systemic therapies will also be illustrated.
Collapse
Affiliation(s)
- Giuseppe Costante
- Endocrinology Clinic, Department of Medicine - Institut Jules Bordet Comprehensive Cancer Center, Université Libre de Bruxelles, Bruxelles, Belgium.
| | | |
Collapse
|
17
|
Wu Y, Xiao Y, Huang T, Zhang X, Zhou H, Zhang X, Wu Y. What makes D-dimer assays suspicious-heterophilic antibodies? J Clin Lab Anal 2019; 33:e22687. [PMID: 30320416 PMCID: PMC6818610 DOI: 10.1002/jcla.22687] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 09/12/2018] [Accepted: 09/16/2018] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Heterophilic antibodies are still an important source of interference in immunoassays, but reports of interference with D-dimers are rare. Are D-dimer level abnormalities, found in the clinic, caused by heterophilic antibodies as well, or are other mechanisms involved? We will elaborate on this issue through two different examples in this article. METHODS Serum from two patients with significantly elevated levels of D-dimers were measured and compared by different methods, diluted, and dealt with heterophilic antibody blockers. At the same time, to retrieve the interference, we focused on the cause of D-dimer false positives and made a systematic review of the literature. RESULTS The D-dimer values were normal (0.49 and 0.15 μg/mL) detected with different testing method and decreased after addition of heterophilic antibody blocking reagent. According to literature data, there were 66.7% (4/6) references showed the interference were heterophilic antibody. CONCLUSIONS The influence of heterophilic antibodies on the measurement of D-dimers remains a big challenge. Different measuring instruments and methods may have significant differences in the measurement of D-dimers. By using a combination of instrumental methods for measuring, incorporating heterophilic antibody blockers, and combining with clinical performance and imaging data, most of the interference can be eliminated.
Collapse
Affiliation(s)
- Ying Wu
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Ying‐Xiu Xiao
- Department of Neurologythe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Teng‐Yi Huang
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Xian‐Yan Zhang
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Huan‐Bing Zhou
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Xue‐Xuan Zhang
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| | - Ying‐E Wu
- Department of Laboratory Medicinethe First Affiliated Hospital of Shantou University Medical CollegeShantouChina
| |
Collapse
|
18
|
Lupoli GA, Barba L, Liotti A, La Civita E, Lupoli R, Riccio E, Portella G, Formisano P, Beguinot F, Terracciano D. Falsely elevated thyroglobulin and calcitonin due to rheumatoid factor in non-relapsing thyroid carcinoma: A case report. Medicine (Baltimore) 2019; 98:e14178. [PMID: 30702570 PMCID: PMC6380811 DOI: 10.1097/md.0000000000014178] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
RATIONALE Thyroglobulin (Tg) is an accurate indicator of clinical outcome after total thyroidectomy in patients with differentiated thyroid carcinoma. Usually, Tg levels agree with whole body scan. However, in some patient, discordant results were found, often because of Tg immunoassay interference. Several reports indicated that 2-site immunoassay interference with heterophile antibodies (HAb) can lead to misinterpretation of the laboratory test result. PATIENT CONCERNS We report a case of a 46-year-old woman referred to our endocrine clinic for markedly increased calcitonin (CT) without the associated clinical picture. The measurement was repeated with the same patient sample on a different analytical platform and the result was an undetectable CT level. The measurement of Tg was repeated on 3 different analytical platforms using chemiluminescence and electrochemiluminescence immunoassays and the results were different on each platform. HAb blocking tubes resulted in a different level of both CT and Tg, suggesting the presence of a heterophile substance in the serum sample. Further characterization showed reactivity to several animal species antibodies and an elevated level of the rheumatoid factor (RF). DIAGNOSES She was diagnosed as papillary thyroid carcinoma. INTERVENTIONS She had undergone thyroidectomy with lymph node dissection and radioactive therapy. OUTCOMES She was found not to have recurrence despite a high serum Tg level. LESSONS Our report illustrates a rare case of falsely elevated tumor markers levels due to assay interference caused by RF. This finding pointed out the importance of close communication between the clinician and laboratory staff in order to bring to light discordance between laboratory test results and clinical picture and avoid unnecessary diagnostic procedures and overtreatment.
Collapse
Affiliation(s)
| | | | | | | | - Roberta Lupoli
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Italy
| | | | | | | | | | | |
Collapse
|
19
|
Clerico A, Belloni L, Carrozza C, Correale M, Dittadi R, Dotti C, Fortunato A, Vignati G, Zucchelli GC, Migliardi M. A Black Swan in clinical laboratory practice: the analytical error due to interferences in immunoassay methods. Clin Chem Lab Med 2018; 56:397-402. [PMID: 29220884 DOI: 10.1515/cclm-2017-0881] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Accepted: 10/22/2017] [Indexed: 12/11/2022]
Abstract
It is well known that the results of immunoassay methods can be affected by specific or non-specific interferences, ranging from 0.4% to 4.0%. The presence of interference may greatly compromise the accuracy of immunoassay analyses causing an error in the measurement, producing false-positive or false-negative results. From a clinical point of view, these analytical errors may have serious implications for patient care because they can cause misdiagnosis or inappropriate treatment. Unfortunately, it is a very difficult task to identify the irregular analytical errors related to immunoassay methods because they are not detectable by normal laboratory quality control procedures, are reproducible within the test system, may be clinically plausible and are relatively rare. The first line of defense against erroneous results is to use in laboratory practice only immunoassay systems with the highest level of robustness against interference. The second line of defense is always taking into account the possibility of interference in immunoassay results. A correct approach should be addressed on identification of samples at high risk of interference. The attainment of this goal requires a critical review of the test result in relation to patient's clinical conditions and literature data, taking into account the analytical characteristics of the immunoassay system. The experts in immunoassay systems should make every effort to find some specific and reliable quality indicators for irregular analytical errors in order to better detect and monitor erroneous immunoassay results due to specific or non-specific interferences.
Collapse
Affiliation(s)
- Aldo Clerico
- Laboratory of Cardiovascular Endocrinology and Cell Biology, Department of Laboratory Medicine, Fondazione CNR Toscana G. Monasterio, Scuola Superiore Sant'Anna, Via Trieste 41, 56126 Pisa, Italy
| | - Lucia Belloni
- Dipartimento di Medicina di laboratorio, Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy
| | - Cinzia Carrozza
- Laboratorio Analisi 1, Fondazione Policlinico Universitario "A. Gemelli", Roma, Italy
| | - Mario Correale
- Clinical Pathology Unit, IRCCS De Bellis, Castellana Grotte, Bari, Italy
| | - Ruggero Dittadi
- Medicina di Laboratorio, Ospedale dell'Angelo ULSS 3 Serenissima, Mestre, Italy
| | - Claudio Dotti
- Dipartimento di Medicina di laboratorio, Arcispedale Santa Maria Nuova - IRCCS, Reggio Emilia, Italy
| | - Antonio Fortunato
- U.O.C. Patologia Clinica, ASUR Marche Area Vasta 5, Ascoli Piceno, Italy
| | | | | | - Marco Migliardi
- S.C. Laboratorio Analisi, A.O. Ordine Mauriziano di Torino, Torino, Italy
| |
Collapse
|
20
|
Lam L, Bagg W, Smith G, Chiu WW, Middleditch MJ, Lim JCH, Kyle CV. Apparent Hyperthyroidism Caused by Biotin-Like Interference from IgM Anti-Streptavidin Antibodies. Thyroid 2018; 28:1063-1067. [PMID: 29808739 DOI: 10.1089/thy.2017.0673] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
BACKGROUND Exclusion of analytical interference is important when there is discrepancy between clinical and laboratory findings. However, interferences on immunoassays are often mistaken as isolated laboratory artefacts. The mechanism of a rare cause of interference in two patients that caused erroneous thyroid function tests, and also affects many other biotin dependent immunoassays, was characterized and reported. PATIENT FINDINGS Patient 1 was a 77-year-old female with worsening fatigue while taking carbimazole over several years. Her thyroid function tests, however, were not suggestive of hypothyroidism. Patient 2 was a 25-year-old female also prescribed carbimazole for apparent primary hyperthyroidism. Despite an elevated free thyroxine, the lowest thyrotropin on record was 0.17 mIU/L. In both cases, thyroid function tests performed by an alternative method were markedly different. Further characterization of both patients' serum demonstrated analytical interference on many immunoassays using the biotin-streptavidin interaction. Sandwich assays (e.g., thyrotropin, follicle-stimulating hormone, troponin T, beta-human chorionic gonadotropin) were falsely low, while competitive assays (e.g., free thyroxine, free triiodothyronine, TSH binding inhibitory immunoglobulin) were falsely high. Pre-incubation of serum with streptavidin microparticles removed the analytical interference, initially suggesting the cause of interference was biotin. However, neither patient had been taking biotin. Instead, a ∼100 kDa immunoglobulin M (IgM) immunoglobulin with high affinity to streptavidin was isolated from each patient's serum. The findings confirm IgM anti-streptavidin antibodies as the cause of analytical interference. SUMMARY Two patients with apparent hyperthyroidism as a result of analytical interference caused by IgM anti-streptavidin antibodies are described. CONCLUSION Analytical interference identified on one immunoassay should raise the possibility of other affected results. Characterization of interference may help to identify other potentially affected immunoassays. In the case of anti-streptavidin antibodies, the pattern of interference mimics that due to biotin ingestion. However, the degree of interference varies between individual assays and between patients.
Collapse
Affiliation(s)
- Leo Lam
- 1 Department of Chemical Pathology, LabPlus, Auckland City Hospital, Auckland City Hospital , Auckland, New Zealand
| | - Warwick Bagg
- 2 Department of Endocrinology, Auckland City Hospital, Auckland City Hospital , Auckland, New Zealand
- 3 Medical Programme Directorate, Faculty of Medical and Health Sciences, University of Auckland , Auckland, New Zealand
| | - Geoff Smith
- 4 Department of Clinical Biochemistry, Southern Community Laboratories Dunedin Hospital , Dunedin, New Zealand
| | - Weldon Wai Chiu
- 1 Department of Chemical Pathology, LabPlus, Auckland City Hospital, Auckland City Hospital , Auckland, New Zealand
| | - Martin James Middleditch
- 5 Auckland Science Analytical Services, University of Auckland , Auckland, New Zealand
- 6 School of Biological Sciences, University of Auckland , Auckland, New Zealand
| | - Julie Ching-Hsia Lim
- 7 Department of Physiology, School of Medical Sciences, Faculty of Medical and Health Sciences, University of Auckland , Auckland, New Zealand
| | - Campbell Vance Kyle
- 1 Department of Chemical Pathology, LabPlus, Auckland City Hospital, Auckland City Hospital , Auckland, New Zealand
- 2 Department of Endocrinology, Auckland City Hospital, Auckland City Hospital , Auckland, New Zealand
- 8 Department of Biochemistry, LabTests , Auckland, New Zealand
| |
Collapse
|
21
|
Abstract
This article summarizes the main principles for the appropriate use of laboratory testing in the diagnosis and management of thyroid disorders, as well as controversies that have arisen in association with some of these biochemical tests. To place a test in perspective, its sensitivity and accuracy should be taken into account. Ordering the correct laboratory tests facilitates the early diagnosis of a thyroid disorder and allows for timely and appropriate treatment. This article focuses on a comprehensive update regarding thyroid-stimulating hormone, thyroxine/triiodothyronine, thyroid autoantibodies, thyroglobulin, and calcitonin. Clinical uses of these biochemical tests are outlined.
Collapse
Affiliation(s)
- Nazanene H Esfandiari
- Division of Metabolism, Endocrinology and Diabetes, Department of Internal Medicine, University of Michigan, Domino's Farms Lobby C, Suite 1300, 24 Frank Lloyd Wright Drive, Ann Arbor, MI 48106, USA
| | - Maria Papaleontiou
- Division of Metabolism, Endocrinology and Diabetes, Department of Internal Medicine, University of Michigan, Domino's Farms Lobby G, Room 1649, 24 Frank Lloyd Wright Drive, Ann Arbor, MI 48106, USA.
| |
Collapse
|
22
|
Censi S, Cavedon E, Fernando SW, Barollo S, Bertazza L, Zambonin L, Zaninotto M, Faggian D, Plebani M, Mian C. Calcitonin measurement and immunoassay interference: a case report and literature review. Clin Chem Lab Med 2017; 54:1861-1870. [PMID: 27166721 DOI: 10.1515/cclm-2015-1161] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 04/13/2016] [Indexed: 02/03/2023]
Abstract
Calcitonin (CT) is currently the most sensitive serological marker of C-cell disease [medullary thyroid carcinoma (MTC) and C-cell hyperplasia]. Starting with a report on a case that occurred at our institution, this review focuses on trying to explain the reasons behind the poor specificity and sensitivity of the various CT immunoassays. A 15-year-old patient was referred to our institution in May 2014 for moderately elevated CT levels. Thyroid ultrasonography (US) documented a colloidal goiter. Secondary causes of the hypercalcitoninemia (hyperCT) were ruled out. The mismatch between the clinical picture and the laboratory results prompted us to search for other reasons for the patient's high CT levels, so we applied the heterophilic blocking tube (HBT) procedure to the patient's sera before the CT assay. Using this pretreatment step, his serum CT concentration dropped to <1 ng/L, as measured at the same laboratory. Measuring plasma CT has an important role in screening for C-cell disease, but moderately elevated serum CT levels need to be placed in their clinical context, bearing in mind all the secondary causes of C-cell hyperplasia and the possibility of laboratory interference, before exposing patients to the risks and costs of further tests.
Collapse
|
23
|
Tang DM, Heller T, Koh C. The many faces of positive hepatitis B surface antigen. Hepatology 2016; 64:1379-81. [PMID: 26890893 PMCID: PMC4990507 DOI: 10.1002/hep.28503] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 01/26/2016] [Accepted: 02/05/2016] [Indexed: 01/28/2023]
Affiliation(s)
- Derek M. Tang
- Digestive Diseases Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland
| | - Theo Heller
- Liver Diseases Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland
| | - Christopher Koh
- Digestive Diseases Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland,Liver Diseases Branch, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
24
|
Herrmann M, Taferner A, Pusceddu I, Crivellaro C. Mother’s instinct – a rare case of multiple test interferences due to heterophile antibodies. Clin Chem Lab Med 2016; 54:e213-6. [DOI: 10.1515/cclm-2015-1025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 12/03/2015] [Indexed: 11/15/2022]
|
25
|
Wells SA, Asa SL, Dralle H, Elisei R, Evans DB, Gagel RF, Lee N, Machens A, Moley JF, Pacini F, Raue F, Frank-Raue K, Robinson B, Rosenthal MS, Santoro M, Schlumberger M, Shah M, Waguespack SG. Revised American Thyroid Association guidelines for the management of medullary thyroid carcinoma. Thyroid 2015; 25:567-610. [PMID: 25810047 PMCID: PMC4490627 DOI: 10.1089/thy.2014.0335] [Citation(s) in RCA: 1383] [Impact Index Per Article: 138.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
INTRODUCTION The American Thyroid Association appointed a Task Force of experts to revise the original Medullary Thyroid Carcinoma: Management Guidelines of the American Thyroid Association. METHODS The Task Force identified relevant articles using a systematic PubMed search, supplemented with additional published materials, and then created evidence-based recommendations, which were set in categories using criteria adapted from the United States Preventive Services Task Force Agency for Healthcare Research and Quality. The original guidelines provided abundant source material and an excellent organizational structure that served as the basis for the current revised document. RESULTS The revised guidelines are focused primarily on the diagnosis and treatment of patients with sporadic medullary thyroid carcinoma (MTC) and hereditary MTC. CONCLUSIONS The Task Force developed 67 evidence-based recommendations to assist clinicians in the care of patients with MTC. The Task Force considers the recommendations to represent current, rational, and optimal medical practice.
Collapse
Affiliation(s)
- Samuel A. Wells
- Genetics Branch, National Cancer Institute, National Institutes of Health, Bethesda, Maryland
| | - Sylvia L. Asa
- Department of Pathology, University Health Network, and Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, Ontario, Canada
| | - Henning Dralle
- Department of General, Visceral, and Vascular Surgery, University Hospital, University of Halle-Wittenberg, Halle/Saale, Germany
| | - Rossella Elisei
- Department of Endocrinology, University of Pisa, Pisa, Italy
| | - Douglas B. Evans
- Department of Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Robert F. Gagel
- Department of Endocrine Neoplasia and Hormonal Disorders, Division of Internal Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Nancy Lee
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York
| | - Andreas Machens
- Department of General, Visceral, and Vascular Surgery, University Hospital, University of Halle-Wittenberg, Halle/Saale, Germany
| | - Jeffrey F. Moley
- Department of Surgery, Washington University School of Medicine, St. Louis, Missouri
| | - Furio Pacini
- Section of Endocrinology and Metabolism, Department of Internal Medicine, Endocrinology and Metabolism and Biochemistry, University of Siena, Policlinico Santa Maria alle Scotte, Siena, Italy
| | - Friedhelm Raue
- Endocrine Practice, Moleculargenetic Laboratory, Medical Faculty, University of Heidelberg, Heidelberg, Germany
| | - Karin Frank-Raue
- Endocrine Practice, Moleculargenetic Laboratory, Medical Faculty, University of Heidelberg, Heidelberg, Germany
| | - Bruce Robinson
- University of Sydney School of Medicine, Sydney, New South Wales, Australia
| | - M. Sara Rosenthal
- Departments of Internal Medicine, Pediatrics and Behavioral Science, University of Kentucky, Lexington, Kentucky
| | - Massimo Santoro
- Dipartimento di Medicina Molecolare e Biotecnologie Mediche, Universita' di Napoli “Federico II,” Napoli, Italy
| | - Martin Schlumberger
- Institut Gustave Roussy, Service de Medecine Nucleaire, Université of Paris-Sud, Villejuif, France
| | - Manisha Shah
- Division of Medical Oncology, Department of Internal Medicine, The Ohio State University, Columbus, Ohio
| | - Steven G. Waguespack
- Department of Endocrine Neoplasia and Hormonal Disorders, Division of Internal Medicine, The University of Texas MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
26
|
Kaplan A, Orhan N, Ilhan' E. False Positive Troponin Levels due to Heterophil Antibodies in a Pregnant Woman. Turk J Emerg Med 2015; 15:47-50. [PMID: 27331194 PMCID: PMC4909945 DOI: 10.5505/1304.7361.2014.00378] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 03/23/2014] [Indexed: 11/04/2022] Open
Abstract
Positive troponin test results in peripheral blood can be detected either during myocardial injury or from falsely positive test results. In this report, we present the positive results of a troponin test in a 24-year-old pregnant woman referred to the emergency department with atypical chest pain, and the clinical algorithm that we used to make the correct diagnosis. This patient presented with the same complaint of chest pain at different times while positive troponin levels were detected. In the absence of signs of myocardial injury, we suspected that heterophil antibodies were playing a major role. Further examinations revealed heterophil antibodies that could cross react with the troponin tests in peripheral blood.
Collapse
Affiliation(s)
- Abdullah Kaplan
- Department of Cardiology, Van Ercis State Hospital, Van, Turkey
| | - Nuri Orhan
- Department of Biochemistry, Van Ercis State Hospital, Van, Turkey
| | - Erkan Ilhan'
- Department of Cardiology, Van Ercis State Hospital, Van, Turkey
| |
Collapse
|
27
|
Pochechueva T, Chinarev A, Bovin N, Fedier A, Jacob F, Heinzelmann-Schwarz V. PEGylation of microbead surfaces reduces unspecific antibody binding in glycan-based suspension array. J Immunol Methods 2014; 412:42-52. [DOI: 10.1016/j.jim.2014.06.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2014] [Revised: 06/24/2014] [Accepted: 06/24/2014] [Indexed: 01/25/2023]
|
28
|
Maia AL, Siqueira DR, Kulcsar MAV, Tincani AJ, Mazeto GMFS, Maciel LMZ. Diagnóstico, tratamento e seguimento do carcinoma medular de tireoide: recomendações do Departamento de Tireoide da Sociedade Brasileira de Endocrinologia e Metabologia. ACTA ACUST UNITED AC 2014; 58:667-700. [DOI: 10.1590/0004-2730000003427] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Accepted: 07/12/2014] [Indexed: 12/20/2022]
Abstract
Introdução O carcinoma medular de tireoide (CMT) origina-se das células parafoliculares da tireoide e corresponde a 3-4% das neoplasias malignas da glândula. Aproximadamente 25% dos casos de CMT são hereditários e decorrentes de mutações ativadoras no proto-oncogene RET (REarranged during Transfection). O CMT é uma neoplasia de curso indolente, com taxas de sobrevida dependentes do estádio tumoral ao diagnóstico. Este artigo descreve diretrizes baseadas em evidências clínicas para o diagnóstico, tratamento e seguimento do CMT. Objetivo O presente consenso, elaborado por especialistas brasileiros e patrocinado pelo Departamento de Tireoide da Sociedade Brasileira de Endocrinologia e Metabologia, visa abordar o diagnóstico, tratamento e seguimento dos pacientes com CMT, de acordo com as evidências mais recentes da literatura. Materiais e métodos: Após estruturação das questões clínicas, foi realizada busca das evidências disponíveis na literatura, inicialmente na base de dados do MedLine-PubMed e posteriormente nas bases Embase e SciELO – Lilacs. A força das evidências, avaliada pelo sistema de classificação de Oxford, foi estabelecida a partir do desenho de estudo utilizado, considerando-se a melhor evidência disponível para cada questão. Resultados Foram definidas 11 questões sobre o diagnóstico, 8 sobre o tratamento cirúrgico e 13 questões abordando o seguimento do CMT, totalizando 32 recomendações. Como um todo, o artigo aborda o diagnóstico clínico e molecular, o tratamento cirúrgico inicial, o manejo pós-operatório e as opções terapêuticas para a doença metastática. Conclusões O diagnóstico de CMT deve ser suspeitado na presença de nódulo tireoidiano e história familiar de CMT e/ou associação com feocromocitoma, hiperparatireoidismo e/ou fenótipo sindrômico característico, como ganglioneuromatose e habitus marfanoides. A punção aspirativa por agulha fina do nódulo, a dosagem de calcitonina sérica e o exame anatomopatológico podem contribuir na confirmação do diagnóstico. A cirurgia é o único tratamento que oferece a possibilidade de cura. As opções de tratamento da doença metastática ainda são limitadas e restritas ao controle da doença. Uma avaliação pós-cirúrgica criteriosa para a identificação de doença residual ou recorrente é fundamental para definir o seguimento e a conduta terapêutica subsequente.
Collapse
|
29
|
Camacho CP, Lindsey SC, Kasamatsu TS, Machado AL, Martins JRM, Biscolla RPM, Dias da Silva MR, Vieira JGH, Maciel RM. Development and application of a novel sensitive immunometric assay for calcitonin in a large cohort of patients with medullary and differentiated thyroid cancer, thyroid nodules, and autoimmune thyroid diseases. Eur Thyroid J 2014; 3:117-24. [PMID: 25114875 PMCID: PMC4109516 DOI: 10.1159/000363055] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2013] [Revised: 04/18/2014] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Serum calcitonin (sCT) is a useful biomarker for medullary thyroid cancer (MTC). Consensus has not been reached concerning sCT measurements in the evaluation of nodular thyroid disease (NTD). OBJECTIVE AND METHODS We developed a new immunofluorometric assay for sCT and have validated it in samples from 794 patients [203 with MTC, 205 with autoimmune thyroid disease (ATD), 248 with NTD, 80 with differentiated thyroid cancer (DTC) 'free of disease', 58 with chronic renal failure (CRF)] and 178 normal individuals, including samples after pentagastrin tests and samples from the washout of 92 FNA procedures in patients with NTD or MTC. We also compared some samples from patients with low or high calcitonin levels using both this assay and the Nichols Institute Diagnostics (NID) assay. RESULTS The assay's analytical sensitivity was 1.0 pg/ml. Considering MTC patients prior to surgery, the cut-off values for the 95% reference range were 11.1 pg/ml for males and 5.5 pg/ml for females and employing the ROC curve were 18.4 pg/ml for males and 7.8 pg/ml for females. sCT in patients with MTC was strongly correlated with disease status. Patients with NTD and ATD did not present false-positive results. sCT measurements were significantly correlated with age (excluding MTC and CRF). The NID test had a strong correlation with our assay. A hook effect was observed only with concentrations >200,000 pg/ml. CONCLUSIONS We developed a novel sCT assay and validated it in healthy subjects, as well as in a large cohort of patients with MTC, NTD, ATD, DTC, and CRF.
Collapse
Affiliation(s)
- Cléber P. Camacho
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
| | - Susan C. Lindsey
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
| | - Teresa S. Kasamatsu
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
| | - Alberto L. Machado
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
- Fleury Medicine and Health, São Paulo, Brazil
| | - João Roberto M. Martins
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
| | - Rosa Paula M. Biscolla
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
- Fleury Medicine and Health, São Paulo, Brazil
| | - Magnus R. Dias da Silva
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
| | - José Gilberto H. Vieira
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
- Fleury Medicine and Health, São Paulo, Brazil
| | - Rui M.B. Maciel
- Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo, Brazil
- Fleury Medicine and Health, São Paulo, Brazil
- *Rui M.B. Maciel, MD, PhD, Laboratory of Molecular and Translational Endocrinology, Division of Endocrinology, Department of Medicine, Escola Paulista de Medicina, Universidade Federal de, São Paulo, Rua Pedro de Toledo 669, 11th Floor, São Paulo, SP 04039-033 (Brazil), E-Mail
| |
Collapse
|
30
|
Matrix effect in ligand-binding assay: the importance of evaluating emerging technologies. Bioanalysis 2014; 6:1033-6. [DOI: 10.4155/bio.14.39] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
31
|
Addressing matrix effects in ligand-binding assays through the use of new reagents and technology. Bioanalysis 2014; 6:1059-67. [DOI: 10.4155/bio.14.75] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
Background: Ligand-binding assays (LBAs) used in the quantification of biotherapeutics for pharmacokinetic determinations rely on interactions between reagents (antibodies or target molecule) and the biotherapeutic. Most LBAs do not employ an analyte extraction procedure and are susceptible to matrix interference. Here, we present a case study on the development of a LBA for the quantification of a PEGylated domain antibody where matrix interference was observed. The assay used to support the single ascending dose study was a plate-based electrochemiluminescent assay with a lower limit of quantification of 80 ng/mL. To meet sensitivity requirements of future studies, new reagents and the Gyrolab™ Workstation were evaluated. Results: Assay sensitivity improved nearly threefold in the final method utilizing new antibody reagents, a buffer containing blockers to human anti-animal antibodies, and the Gyrolab Workstation. Conclusion: Experimental data indicate that all factors changed played a role in overcoming matrix effects.
Collapse
|
32
|
Burska A, Boissinot M, Ponchel F. Cytokines as biomarkers in rheumatoid arthritis. Mediators Inflamm 2014; 2014:545493. [PMID: 24733962 PMCID: PMC3964841 DOI: 10.1155/2014/545493] [Citation(s) in RCA: 127] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Accepted: 01/21/2014] [Indexed: 12/17/2022] Open
Abstract
RA is a complex disease that develops as a series of events often referred to as disease continuum. RA would benefit from novel biomarker development for diagnosis where new biomarkers are still needed (even if progresses have been made with the inclusion of ACPA into the ACR/EULAR 2010 diagnostic criteria) and for prognostic notably in at risk of evolution patients with autoantibody-positive arthralgia. Risk biomarkers for rapid evolution or cardiovascular complications are also highly desirable. Monitoring biomarkers would be useful in predicting relapse. Finally, predictive biomarkers for therapy outcome would allow tailoring therapy to the individual. Increasing numbers of cytokines have been involved in RA pathology. Many have the potential as biomarkers in RA especially as their clinical utility is already established in other diseases and could be easily transferable to rheumatology. We will review the current knowledge's relation to cytokine used as biomarker in RA. However, given the complexity and heterogeneous nature of RA, it is unlikely that a single cytokine may provide sufficient discrimination; therefore multiple biomarker signatures may represent more realistic approach for the future of personalised medicine in RA.
Collapse
Affiliation(s)
- Agata Burska
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, The University of Leeds, Leeds, UK
| | - Marjorie Boissinot
- Leeds Institute of Cancer and Pathology Research, The University of Leeds, Leeds, UK
| | - Frederique Ponchel
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, The University of Leeds, Leeds, UK ; NIHR Leeds Musculoskeletal Biomedical Research Unit, The Leeds Trust Teaching Hospital, Leeds, UK ; Leeds Institute of Rheumatic and Musculoskeletal Medicine, Translational Research in Immune Mediated Inflammatory Diseases Group, Clinical Sciences Building, St. James's University Hospital, Leeds LS9 7TF, UK
| |
Collapse
|
33
|
Grasko J, Willliams R, Beilin J, Glendenning P, Fermoyle S, Vasikaran S. A diagnostic conundrum: heterophilic antibody interference in an adrenocorticotropic hormone immunoassay not detectable using a proprietary heterophile blocking reagent. Ann Clin Biochem 2013; 50:433-7. [DOI: 10.1177/0004563213487514] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Context Heterophilic antibodies are a well-described interferent but poorly appreciated and are often not a recognized problem affecting most immunoassays. We describe for the first time heterophilic antibodies interference affecting an adrenocorticotropic hormone (ACTH) assay in a patient with Cushing’s syndrome due to bilateral nodular adrenal hyperplasia. Case A 60-year-old retired female nurse underwent extensive invasive investigations, which were ultimately unnecessary, as a result of initial analytical interference in the ACTH assay, which could not be resolved using a proprietary heterophilic binding reagent. Results This case highlights the inherent difficulty of diagnosing Cushing’s syndrome and the large emphasis placed on laboratory tests. The consequence of not initially identifying interference in this patient’s laboratory test results led to unnecessary and costly investigations with potentially adverse outcomes. Conclusions Clinicians and the laboratory community need to be continuously vigilant and view laboratory results with caution when they are inconsistent with the clinical picture. This approach is paramount, especially at a time of increasing automation and ever-diminishing scientist involvement in sample processing.
Collapse
Affiliation(s)
- Jonathan Grasko
- Department of Biochemistry, QE2 Medical Center, Nedlands, Australia
| | - Robin Willliams
- Core Biochemistry Laboratory, Fremantle Hospital, Fremantle, Australia
| | - Jonathan Beilin
- Department of Diabetes and Endocrinology, Royal Perth Hospital, Perth, Australia
| | - Paul Glendenning
- Core Clinical Pathology and Biochemistry, Royal Perth Hospital, Perth, Australia
- School of Pathology and Laboratory Medicine, University of Western Australia, Perth, Australia
- School of Medicine and Pharmacology, University of Western Australia, Perth, Australia
| | - Soraya Fermoyle
- Anatomical Pathology, Royal Perth Hospital, Perth, Perth, Australia
| | - Samuel Vasikaran
- Core Clinical Pathology and Biochemistry, Royal Perth Hospital, Perth, Australia
- School of Pathology and Laboratory Medicine, University of Western Australia, Perth, Australia
| |
Collapse
|
34
|
Cappy H, Pigny P, Leroy-Billiard M, Dewailly D, Catteau-Jonard S. Falsely elevated serum antimüllerian hormone level in a context of heterophilic interference. Fertil Steril 2013; 99:1729-32. [DOI: 10.1016/j.fertnstert.2012.12.037] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Revised: 12/21/2012] [Accepted: 12/21/2012] [Indexed: 10/27/2022]
|
35
|
Camacho CP, Lindsey SC, Melo MCC, Yang JH, Germano-Neto F, Valente FDOF, Lima TRN, Biscolla RPM, Vieira JGH, Cerutti JM, Dias-da-Silva MR, Maciel RMB. Measurement of calcitonin and calcitonin gene-related peptide mRNA refines the management of patients with medullary thyroid cancer and may replace calcitonin-stimulation tests. Thyroid 2013; 23:308-16. [PMID: 23259706 PMCID: PMC3593689 DOI: 10.1089/thy.2012.0361] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND Serum calcitonin (sCT) is the main tumor marker for medullary thyroid cancer (MTC), but it has certain limitations. Various sCT assays may have important intra-assay or interassay variation and may yield different and sometimes conflicting results. A pentagastrin- or calcium-stimulation calcitonin (CT) test may be desirable in some situations. Alternatively, or in the absence of the stimulation test, mRNA detection offers the advantages of being more comfortable and less invasive; it only requires blood collection and has no side effects. The objective of this study was to investigate the applicability of measuring calcitonin-related polypeptide alpha (CALCA) gene transcripts (CT-CALCA and calcitonin gene-related peptide [CGRP]-CALCA) in patients with MTC and in relatives diagnosed with a RET mutation and to test mRNA as an alternative diagnostic tool for the calcitonin-stimulation test. METHODS Twenty-three healthy controls and 26 individuals evaluated for MTC were selected, including patients with sporadic or hereditary MTC and RET mutation-carrying relatives. For molecular analysis, RNA was extracted from peripheral blood, followed by cDNA synthesis using 3.5 μg of total RNA. Quantitative real-time polymerase chain reaction (RT-qPCR) was performed with SYBR Green and 200 nM of each primer for the two specific mRNA targets (CT-CALCA or CGRP-CALCA) and normalized with the ribosomal protein S8 as the reference gene. RESULTS We detected CALCA transcripts in the blood samples and observed a positive correlation between them (r=0.946, p<0.0001). Both mRNAs also correlated with sCT (CT-CALCA, r=0.713, p<0.0001; CGRP-CALCA, r=0.714, p<0.0001). The relative expression of CT-CALCA and CGRP-CALCA presented higher clinical sensitivity (86.67 and 100, respectively), specificity (97.06 and 97.06), positive predictive value (92.86 and 93.75), and negative predictive value (94.29 and 100), than did sCT (73.33, 82.35, 64.71, and 87.50, respectively). In addition, the CALCA transcript measurement mirrored the response to the pentagastrin test. CONCLUSION We demonstrate that the measurement of CALCA gene transcripts in the bloodstream is feasible and may refine the management of patients with MTC and RET mutation-carrying relatives. We propose considering the application of this diagnostic tool as an alternative to the calcitonin-stimulation test.
Collapse
Affiliation(s)
- Cléber P Camacho
- Laboratory of Molecular and Translational Endocrinology, Department of Medicine, Escola Paulista de Medicina, Federal University of São Paulo, São Paulo, Brazil
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
|
37
|
O'Hara DM, Theobald V, Egan AC, Usansky J, Krishna M, TerWee J, Maia M, Spriggs FP, Kenney J, Safavi A, Keefe J. Ligand binding assays in the 21st century laboratory: recommendations for characterization and supply of critical reagents. AAPS JOURNAL 2012; 14:316-28. [PMID: 22415613 DOI: 10.1208/s12248-012-9334-9] [Citation(s) in RCA: 86] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2011] [Accepted: 02/07/2012] [Indexed: 11/30/2022]
Abstract
Critical reagents are essential components of ligand binding assays (LBAs) and are utilized throughout the process of drug discovery, development, and post-marketing monitoring. Successful lifecycle management of LBA critical reagents minimizes assay performance problems caused by declining reagent activity and can mitigate the risk of delays during preclinical and clinical studies. Proactive reagent management assures adequate supply. It also assures that the quality of critical reagents is appropriate and consistent for the intended LBA use throughout all stages of the drug development process. This manuscript summarizes the key considerations for the generation, production, characterization, qualification, documentation, and management of critical reagents in LBAs, with recommendations for antibodies (monoclonal and polyclonal), engineered proteins, peptides, and their conjugates. Recommendations are given for each reagent type on basic and optional characterization profiles, expiration dates and storage temperatures, and investment in a knowledge database system. These recommendations represent a consensus among the authors and should be used to assist bioanalytical laboratories in the implementation of a best practices program for critical reagent life cycle management.
Collapse
Affiliation(s)
- Denise M O'Hara
- Department of Pharmacokinetics, Dynamics and Metabolism, Pfizer Inc, One Burtt Road, Andover, Massachusetts 01810, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
The coming of age of liquid chromatography coupled to tandem mass spectrometry in the endocrinology laboratory. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 883-884:50-8. [DOI: 10.1016/j.jchromb.2011.08.027] [Citation(s) in RCA: 67] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2011] [Accepted: 08/19/2011] [Indexed: 02/07/2023]
|
39
|
Spurious elevation of serum PSA after curative treatment for prostate cancer: clinical consequences and the role of heterophilic antibodies. Prostate Cancer Prostatic Dis 2011; 15:182-8. [PMID: 22105412 DOI: 10.1038/pcan.2011.58] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Various interferences can cause spurious results for common laboratory tests. Although rare, heterophilic antibodies may produce false elevations in PSA that could prompt unnecessary therapy in men previously treated for prostate cancer. The aim of this study was to determine the prevalence of small, spurious PSA elevations, and the role of heterophilic antibodies. METHODS Phase I: all PSA tests drawn and measured between 27 October 2008 and 26 October 2010 at Vanderbilt University Medical Center were analyzed (n=17 133). Patients who had been treated for prostate cancer with PSA values that changed from undetectable to detectable were evaluated. Phase II: patients with a detectable PSA ≤0.5 ng ml(-1) measured between 24 October 2010 and 19 January 2011 were studied prospectively (n=1288). If any patient had a previously undetectable PSA value, their serum was tested for heterophilic antibody interference. RESULTS Phase I: 11 men had a spuriously elevated PSA after curative treatment for prostate cancer (0.3%). Mean time to PSA elevation was 3.4±5.5 years, and mean elevation in PSA was 0.33±0.28 ng ml(-1). Each patient's PSA was undetectable after being repeated, and no patient went on to unnecessary treatment. Phase II: 10 men had a newly detectable PSA, 9 of whom had a history of prostate cancer. Each tested negative for interfering heterophilic antibodies when their PSA test was repeated with a heterophilic antibody-blocking reagent. CONCLUSIONS In a large cohort, we estimate the prevalence of spuriously elevated PSA values in our population to be 0.3%. No patient with a prostate cancer history was subjected to unnecessary diagnostic evaluation or treatment. On prospective evaluation of PSA conversion to low detectable levels, no patient had evidence of interfering heterophilic antibodies. When using PSA for post-treatment surveillance, it is crucial to confirm all concerning values and consider the presence of a spurious elevation in PSA if the value does not correlate with the clinical scenario.
Collapse
|
40
|
Sturgeon CM, Viljoen A. Analytical error and interference in immunoassay: minimizing risk. Ann Clin Biochem 2011; 48:418-32. [DOI: 10.1258/acb.2011.011073] [Citation(s) in RCA: 137] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
41
|
Giovanella L, Suriano S. Spurious hypercalcitoninemia and heterophilic antibodies in patients with thyroid nodules. Head Neck 2011; 33:95-7. [DOI: 10.1002/hed.21405] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
42
|
Tran T, Gianoukakis AG. Familial thyroid neoplasia: impact of technological advances on detection and monitoring. Curr Opin Endocrinol Diabetes Obes 2010; 17:425-31. [PMID: 20729730 DOI: 10.1097/med.0b013e32833dd19f] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE OF REVIEW To weigh the clinical impact of new technological insights into heritable thyroid malignancies. RECENT FINDINGS Medullary thyroid carcinoma and familial nonmedullary thyroid cancers represent the small minority of thyroid cancers that are inherited. New insights into the genetic alterations and molecular mechanisms implicated in these tumors are serving to refine the clinical tools available for their initial diagnosis as well as subsequent follow-up. In addition to an analysis of rearranged during transfection mutations and calcitonin profiles in medullary thyroid carcinoma, this review includes emphasis on familial nonmedullary thyroid cancer syndromes, including genetic findings in familial papillary thyroid cancer, familial adenomatous polyposis, Cowden syndrome, Carney complex, and Werner syndrome. SUMMARY Genetic mutational information is increasingly available on medullary and familial nonmedullary thyroid cancer and their associated syndromes. The clinical significance of this information for affected patients and their families continues to undergo evaluation.
Collapse
Affiliation(s)
- Theresa Tran
- Division of Endocrinology and Metabolism, Harbor-UCLA Medical Center, Torrance, California 90502, USA
| | | |
Collapse
|
43
|
Webster R, Fahie-Wilson M, Barker P, Chatterjee VK, Halsall DJ. Immunoglobulin interference in serum follicle-stimulating hormone assays: autoimmune and heterophilic antibody interference. Ann Clin Biochem 2010; 47:386-9. [PMID: 20511373 DOI: 10.1258/acb.2010.010044] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Interference in immunoassay caused by endogenous immunoglobulin is a cause of incorrect laboratory results that can drastically affect patient management. Two cases of immunoglobulin interference in serum follicle-stimulating hormone (FSH) assays are presented. These cases illustrate two common mechanisms for false-positive interference in two-site (sandwich) immunoassays. The first case describes a circulating autoimmune FSH immunoglobulin complex ('macro'-FSH), which has not been previously described for FSH, and the second a cross-linking antibody directed against the assay reagents. Immunoglobulin interference was detected and characterized using a combination of method comparison, immunosubtraction and size exclusion chromatography.
Collapse
Affiliation(s)
- Rachel Webster
- Department of Clinical Biochemistry, Birmingham Children's Hospital, Steelhouse Lane, Birmingham, UK
| | | | | | | | | |
Collapse
|
44
|
Kim JM, Chung KW, Kim SW, Choi SH, Min HS, Kim JN, Won WJ, Kim SK, Lee JI, Chung JH, Kim SW. Spurious hypercalcitoninemia in patients with nodular thyroid disease induced by heterophilic antibodies. Head Neck 2010; 32:68-75. [PMID: 19536770 DOI: 10.1002/hed.21145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Serum calcitonin is the most useful tumor marker for the diagnosis and follow-up of medullary thyroid carcinoma (MTC). Spurious hypercalcitoninemia caused by heterophilic antibody interference (HAI) is rarely found in patients without MTC. METHODS We studied 2 patients with hypercalcitoninemia and thyroid nodules, but no evidence of MTC on fine-needle aspiration cytology. We performed calcium stimulation tests, measured serum calcitonin with another calcitonin kit, performed dilution tests, and remeasured serum calcitonin after applying heterophilic blocking tubes. RESULTS In a 31-year-old woman with no response to the calcium stimulation test, serum calcitonin was <5 pg/mL using another kit. After we applied heterophilic blocking tubes, the serum calcitonin level decreased to normal range. We concluded that patient had spurious hypercalcitoninemia. In a 63-year-old woman, all tests revealed that the patient had true hypercalcitoninemia. The patient underwent total thyroidectomy that revealed MTC. CONCLUSIONS We suggest that patients suspected for spurious hypercalcitoninemia should undergo further investigation due to HAI.
Collapse
Affiliation(s)
- Jung Min Kim
- Research Institute and Hospital, National Cancer Center, Gyeonggi, Korea
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Giovanella L, Ceriani L. Spurious increase in serum chromogranin A: the role of heterophilic antibodies. Clin Chem Lab Med 2010; 48:1497-9. [DOI: 10.1515/cclm.2010.293] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
46
|
Cooper DS, Doherty GM, Haugen BR, Kloos RT, Lee SL, Mandel SJ, Mazzaferri EL, McIver B, Pacini F, Schlumberger M, Sherman SI, Steward DL, Tuttle RM. Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid 2009; 19:1167-214. [PMID: 19860577 DOI: 10.1089/thy.2009.0110] [Citation(s) in RCA: 4700] [Impact Index Per Article: 293.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Thyroid nodules are a common clinical problem, and differentiated thyroid cancer is becoming increasingly prevalent. Since the publication of the American Thyroid Association's guidelines for the management of these disorders was published in 2006, a large amount of new information has become available, prompting a revision of the guidelines. METHODS Relevant articles through December 2008 were reviewed by the task force and categorized by topic and level of evidence according to a modified schema used by the United States Preventative Services Task Force. RESULTS The revised guidelines for the management of thyroid nodules include recommendations regarding initial evaluation, clinical and ultrasound criteria for fine-needle aspiration biopsy, interpretation of fine-needle aspiration biopsy results, and management of benign thyroid nodules. Recommendations regarding the initial management of thyroid cancer include those relating to optimal surgical management, radioiodine remnant ablation, and suppression therapy using levothyroxine. Recommendations related to long-term management of differentiated thyroid cancer include those related to surveillance for recurrent disease using ultrasound and serum thyroglobulin as well as those related to management of recurrent and metastatic disease. CONCLUSIONS We created evidence-based recommendations in response to our appointment as an independent task force by the American Thyroid Association to assist in the clinical management of patients with thyroid nodules and differentiated thyroid cancer. They represent, in our opinion, contemporary optimal care for patients with these disorders.
Collapse
|
47
|
Chisholm C, Spiekerman M, Koss W. Undetectable Prostate-Specific Antigen in the Absence of Previous Prostatectomy: Laboratory Error or True Finding? Lab Med 2009. [DOI: 10.1309/lmcrxswtmt6hcgl4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
48
|
Bjerner J. Human anti‐immunoglobulin antibodies interfering in immunometric assays. Scandinavian Journal of Clinical and Laboratory Investigation 2009; 65:349-64. [PMID: 16081358 DOI: 10.1080/00365510510025818] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- J Bjerner
- Central Laboratory, Norwegian Radium Hospital, Montebello, Oslo, Norway.
| |
Collapse
|
49
|
Kloos RT, Eng C, Evans DB, Francis GL, Gagel RF, Gharib H, Moley JF, Pacini F, Ringel MD, Schlumberger M, Wells SA. Medullary thyroid cancer: management guidelines of the American Thyroid Association. Thyroid 2009; 19:565-612. [PMID: 19469690 DOI: 10.1089/thy.2008.0403] [Citation(s) in RCA: 773] [Impact Index Per Article: 48.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND Inherited and sporadic medullary thyroid cancer (MTC) is an uncommon and challenging malignancy. The American Thyroid association (ATA) chose to create specific MTC Clinical Guidelines that would bring together and update the diverse MTC literature and combine it with evidence-based medicine and the knowledge and experience of a panel of expert clinicians. METHODS Relevant articles were identified using a systematic PubMed search and supplemented with additional published materials. Evidence-based recommendations were created and then categorized using criteria adapted from the United States Preventive Services Task Force, Agency for Healthcare Research and Quality. RESULTS Clinical topics addressed in this scholarly dialog included: initial diagnosis and therapy of preclinical disease (including RET oncogene testing and the timing of prophylactic thyroidectomy), initial diagnosis and therapy of clinically apparent disease (including preoperative testing and imaging, extent of surgery, and handling of devascularized parathyroid glands), initial evaluation and treatment of postoperative patients (including the role of completion thyroidectomy), management of persistent or recurrent MTC (including the role of tumor marker doubling times, and treatment of patients with distant metastases and hormonally active metastases), long-term follow-up and management (including the frequency of follow-up and imaging), and directions for future research. CONCLUSIONS One hundred twenty-two evidence-based recommendations were created to assist in the clinical care of MTC patients and to share what we believe is current, rational, and optimal medical practice.
Collapse
|
50
|
Pedrosa W, Teixeira L. Interference of heterophilic antibodies with free prostate-specific antigen in the Beckman-Coulter (Unicel DxI) assay, inverting the free/total prostate-specific antigen ratio. Ann Clin Biochem 2009; 46:344-5. [PMID: 19454533 DOI: 10.1258/acb.2009.008242] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|