1
|
Fallahzadeh F, Nouri F, Rashvand E, Heidari S, Najafi F, Soltanian N. Enamel changes of bleached teeth following application of an experimental combination of chitosan-bioactive glass. BMC Oral Health 2024; 24:445. [PMID: 38609921 PMCID: PMC11015582 DOI: 10.1186/s12903-024-04195-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 03/27/2024] [Indexed: 04/14/2024] Open
Abstract
BACKGROUND Considering the extensive use of bleaching agents and the occurrence of side effects such as enamel demineralization, this study aimed to assess the enamel changes of bleached teeth following the experimental application of chitosan-bioactive glass (CH-BG). METHODS In this in vitro study, CH-BG (containing 66% BG) was synthesized and characterized by Fourier-transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). Thirty sound human premolars were bleached with 40% hydrogen peroxide, and the weight% of calcium and phosphorus elements of the buccal enamel surface was quantified before and after bleaching by scanning electron microscopy/ energy-dispersive X-ray spectroscopy (SEM, EDX). Depending on the surface treatment of the enamel surface, the specimens were divided into three groups (n = 10): control (no treatment), MI Paste (MI), and CH-BG. Then the specimens were stored in artificial saliva for 14 days. The SEM/EDX analyses were performed again on the enamel surface. Data were analyzed by one-way ANOVA and Tukey's test and a p-value of < 0.05 was considered statistically significant. RESULTS In all groups, the weight% of calcium and phosphorus elements of enamel decreased after bleaching; this reduction was significant for phosphorus (p < 0.05) and insignificant for calcium (p > 0.05). After 14 days of remineralization, the weight% of both calcium and phosphorus elements was significantly higher compared to their bleached counterparts in both MI and CH-BG groups (p < 0.05). Following the remineralization process, the difference between MI and CH-BG groups was not significant (p > 0.05) but both had a significant difference with the control group in this regard (p < 0.05). CONCLUSIONS The synthesized CH-BG compound showed an efficacy comparable to that of MI Paste for enamel remineralization of bleached teeth.
Collapse
Affiliation(s)
- Farnoosh Fallahzadeh
- Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Shahid Bahonar Boulevard, Qazvin, Iran
| | - Fahimeh Nouri
- Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Shahid Bahonar Boulevard, Qazvin, Iran.
| | - Ensiyeh Rashvand
- Department of Operative Dentistry, School of Dentistry, Alborz University of Medical Sciences, Golshahr, Karaj, Iran.
| | - Soolmaz Heidari
- Dental Caries Prevention Research Center, Qazvin University of Medical Sciences, Shahid Bahonar Boulevard, Qazvin, Iran
| | - Farhood Najafi
- Department of Resin and Additives, Institute for Color Science and Technology, Tehran, Iran
| | - Negar Soltanian
- Department of Restorative Dentistry, School of Dentistry, Urmia University of Medical Sciences, Urmia, Iran
| |
Collapse
|
2
|
Américo MA, Portella FF, Zimmer R, Garcia FR, Porto DJ, Barbosa VL, Oballe H, Reston EG. Effect of a Toothpaste for Sensitive Teeth on the Sensitivity and Effectiveness of In-office Dental Bleaching: A Randomized Clinical Trial. Oper Dent 2023; 48:627-637. [PMID: 37881142 DOI: 10.2341/23-009-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/11/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVES The present study aimed to evaluate the desensitizing effect of toothpaste for sensitive teeth on patient tooth sensitivity and on bleaching efficacy of the 38% hydrogen peroxide bleaching agent used for in-office bleaching compared to a regular toothpaste in a randomized clinical trial. METHODS AND MATERIALS Forty-eight patients having maxillary right central incisors with darkness greater than A1 were selected for the present double-blind randomized clinical trial. Patients were randomly allocated into two groups: the placebo group, which used regular toothpaste, and the experimental group, which used sensitivity toothpaste. The intervention consisted of applying toothpaste with the aid of an individual tray for a period of 4 minutes daily, starting one week before the first bleaching session and interrupting use immediately after the second session. After allocation to one of the groups, individuals received in-office dental bleaching with a 40-minute application of 38% hydrogen peroxide for two sessions with an interval of one week. The incidence and intensity of sensitivity were assessed using a visual analogue scale and a numeric analogue scale. Sensitivity was measured immediately before each session, 1 hour, 24 hours, and 48 hours after each bleaching session and four weeks after the second bleaching session. Tooth shade was evaluated using a spectrophotometer and by comparison with the VITA Classical Shade Guide (Vita Zahnfabrik, Bad Säckingen, Germany). Tooth shade was evaluated before the first bleaching session, one week after the first bleaching session, one week after the second bleaching session and four weeks after the second bleaching session. Participants and professionals who performed the bleaching, shade, and sensitivity assessments were blinded to the group of patients they were treating or assessing. For the incidence of hypersensitivity, the results were evaluated by comparing the groups at different evaluation times with the Mann-Whitney test for comparison between groups, the Friedman test for repeated measures, and the Tukey test for comparison of times. Shade change on the guide was analyzed using the Mann-Whitney test for comparison between groups and the Wilcoxon test for comparison between times. Shade change by the spectrophotometer was analyzed using the t-test for comparison between groups and the paired t-test for comparison between times. All analyses were performed with a significance level of 5%. RESULTS There was no difference in the pattern of dental hypersensitivity between groups. For all shade measures, there was no difference between the bleaching results, and no statistically significant difference was observed between the study groups. CONCLUSION The use of arginine-based desensitizing toothpaste did not interfere with the bleaching ability of hydrogen peroxide and was not effective in reducing the sensitivity caused by in-office tooth bleaching.
Collapse
Affiliation(s)
- M A Américo
- Michelle Azeredo Américo, DDS, MS, PhD, Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - F F Portella
- Fernando Freitas Portella, DDS, MS, PhD, Feevale University, Novo Hamburgo, Brazil
| | - R Zimmer
- Roberto Zimmer, DDS, MS, Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil and Feevale University, Novo Hamburgo, Brazil
| | - F R Garcia
- Filipe Reis Garcia, DDS, MS, PhD, Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - D J Porto
- Denner Jardim Porto, DDS, Undergraduate in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - V L Barbosa
- Viviane Leal Barbosa, DDS, MS, Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - Hjr Oballe
- Harry Juan Rivera Oballe, DDS, MS, PhD, Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| | - E G Reston
- *Eduardo G. Reston, DDS, MSD, PhD, head of Postgraduate Program in Dentistry, Lutheran University of Brazil (Ulbra), Canoas, Brazil
| |
Collapse
|
3
|
Kim DH, Bae J, Heo JH, Park CH, Kim EB, Lee JH. Nanoparticles as Next-Generation Tooth-Whitening Agents: Progress and Perspectives. ACS NANO 2022; 16:10042-10065. [PMID: 35704786 DOI: 10.1021/acsnano.2c01412] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Whitening agents, such as hydrogen peroxide and carbamide peroxide, are currently used in clinical applications for dental esthetic and dental care. However, the free radicals generated by whitening agents cause pathological damage; therefore, their safety issues remain controversial. Furthermore, whitening agents are known to be unstable and short-lived. Since 2001, nanoparticles (NPs) have been researched for use in tooth whitening. Importantly, nanoparticles not only function as abrasives but also release reactive oxygen species and help remineralization. This review outlines the historical development of several NPs based on their whitening effects and side effects. NPs can be categorized into metals or metal oxides, ceramic particles, graphene oxide, and piezoelectric particles. Moreover, the status quo and future prospects are discussed, and recent progress in the development of NPs and their applications in various fields requiring tooth whitening is examined. This review promotes the research and development of next-generation NPs for use in tooth whitening.
Collapse
Affiliation(s)
- Dai-Hwan Kim
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Jina Bae
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Jun Hyuk Heo
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
- Advanced Materials Technology Research Center, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Cheol Hyun Park
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Eun Bi Kim
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| | - Jung Heon Lee
- School of Advanced Materials Science and Engineering, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
- Advanced Materials Technology Research Center, Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
- SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
- Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon 16419, Republic of Korea
| |
Collapse
|
4
|
Ortecho-Zuta U, de Oliveira Duque CC, de Oliveira Ribeiro RA, Leite ML, Soares DG, Hebling J, Briso ALF, de Souza Costa CA. Strategy for reducing cytotoxicity and obtaining esthetic efficacy with 15 min of in-office dental bleaching. Clin Oral Investig 2022; 26:4099-4108. [PMID: 35199193 DOI: 10.1007/s00784-022-04379-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 01/13/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Evaluate in vitro the esthetic efficacy and cytotoxicity of a bleaching gel containing 35% hydrogen peroxide (BG-35%H2O2), applied for different time intervals, on enamel coated or not with polymeric biomaterials. MATERIALS AND METHODS Nanofiber scaffolds (NSc) and a primer catalyst (PrCa) were used to coat the bovine enamel/dentin discs before the application of BG-35%H2O2, according to the following groups: G1-negative control (NC, without treatment); G2, G3, and G4-BG-35%H2O2 applied for 3 × 15, 2 × 15, and 15 min; G5, G6, and G7-BG-35%H2O2 applied on enamel coated with NSc and PrCa for 3 × 15; 2 × 15, and 15 min, respectively. The culture medium with components of gel diffused through the discs was applied on MDPC-23 cells, which were evaluated regarding to viability (VB), integrity of the membrane (IM), and oxidative stress (OxS). The quantity of H2O2 diffused and esthetic efficacy (ΔE/ΔWI) of the dental tissues were also analyzed (ANOVA/Tukey; p < 0.05). RESULTS Only G7 was similar to G1 regarding VB (p > 0.05). The lowest value of H2O2 diffusion occurred in G4 and G7, where the cells exhibited the lowest OxS than G2 (p < 0.05). Despite G5 showing the greatest ΔE regarding other groups (p < 0.05), the esthetic efficacy observed in G7 was similar to G2 (p > 0.05). ΔWI indicated a greater bleaching effect for groups G5, G6, and G7 (p < 0.05). CONCLUSION Coating the dental enamel with polymeric biomaterials reduced the time and the cytotoxicity of BG-35%H2O2. CLINICAL SIGNIFICANCE Coating the dental enamel with polymeric biomaterials allows safer and faster BG-35%H2O2 application.
Collapse
Affiliation(s)
- Uxua Ortecho-Zuta
- Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, São Paulo State University (Unesp), Rua Humaitá, 1680, Araraquara, SP, 14801-903, Brazil
| | - Carla Caroline de Oliveira Duque
- Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, São Paulo State University (Unesp), Rua Humaitá, 1680, Araraquara, SP, 14801-903, Brazil
| | - Rafael Antonio de Oliveira Ribeiro
- Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, São Paulo State University (Unesp), Rua Humaitá, 1680, Araraquara, SP, 14801-903, Brazil
| | - Maria Luísa Leite
- Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, São Paulo State University (Unesp), Rua Humaitá, 1680, Araraquara, SP, 14801-903, Brazil
| | - Diana Gabriela Soares
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Rua Alameda Dr. Octávio Pinheiro Brisolla, 9-75, Bauru, SP, 17012-901, Brazil
| | - Josimeri Hebling
- Departament of Orthodontics and Pediatric Dentistry, Araraquara School of Dentistry, University São Paulo State (Unesp), Rua Humaitá, 1680, Araraquara, SP, 14801-903, Brazil
| | - André Luiz Fraga Briso
- Department of Restorative Dentistry, Araçatuba, School of Dentistry University São Paulo State University (Unesp), Rua José Bonifácio 1193, Vila Mendonça, 16015-050, Brazil
| | - Carlos Alberto de Souza Costa
- Department of Physiology and Pathology, Araraquara School of Dentistry, São Paulo State University (Unesp), Rua Humaitá, Araraquara, SP, 168014801-903, Brazil.
| |
Collapse
|
5
|
Li Z, Wu Z, Wang J, Huang M, Lin M. Expanding the applications of photodynamic therapy-tooth bleaching. Clin Oral Investig 2022; 26:2175-2186. [PMID: 34657223 DOI: 10.1007/s00784-021-04199-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Accepted: 09/21/2021] [Indexed: 01/10/2023]
Abstract
OBJECTIVES The current tooth bleaching materials are associated with adverse effect. Photodynamic method based on a novel photosensitizer alone, without combining with peroxides, is evaluated for tooth bleaching application. MATERIALS AND METHODS Teeth samples were randomly divided into 3 groups with different treatment schemes, including negative control group (group A, physiological saline), experimental group (group B, ZnPc(Lys)5), and the positive control group (group C, hydrogen peroxide). Tooth color, surface microhardness, and roughness were determined at baseline, right after the first and second phase of bleaching, as well as 1 week and 1 month post-bleaching. Four samples in each group was randomly selected to evaluate the changes in surface morphology using the scanning electron microscope. RESULTS The color change values (ΔE) in group B (7.10 ± 1.03) and C (12.22 ± 2.35) were significantly higher than that in group A (0.93 ± 0.30, P < 0.05). Additionally, surface microhardness and roughness were significantly affected in group C, but not in the group A and B. Furthermore, the scanning electron microscope images showed no adverse effect of enamel in the group A and B while the group C demonstrated corrosive changes. CONCLUSIONS ZnPc(Lys)5 had a satisfactory bleaching effect and is promising to be a new type of tooth bleaching agent. CLINICAL RELEVANCE The current tooth bleaching materials give a satisfactory clinical outcome and long-term stability, but associated with some adverse reactions. Photosenstizer ZnPc(Lys)5 eliminated the main side effects observed in hydrogen peroxide-based agents on the enamel, and also had a satisfactory bleaching effect and provide a novel selective bleaching scheme for clinical use.
Collapse
Affiliation(s)
- Zhengquan Li
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Road, Fujian, 350000, China
| | - Zhouyan Wu
- Institute of Stomatology & Laboratory of Oral Tissue Engineering, School and Hospital of Stomatology, Fujian Medical University, Fujian, 350000, China
| | - Jie Wang
- Research Center of Dental Esthetics and Biomechanics, Fujian Medical University, Fujian, 350000, China
| | - Mingdong Huang
- College of Chemistry, Fuzhou University, 2 Xueyuan Road, Fuzhou, 350108, Fujian, China.
| | - Minkui Lin
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, 246 Yangqiao Zhong Road, Fujian, 350000, China.
- Institute of Stomatology & Laboratory of Oral Tissue Engineering, School and Hospital of Stomatology, Fujian Medical University, Fujian, 350000, China.
| |
Collapse
|
6
|
Piknjač A, Soldo M, Illeš D, Knezović Zlatarić D. Patients' Assessments of Tooth Sensitivity Increase One Day Following Different Whitening Treatments. Acta Stomatol Croat 2021; 55:280-290. [PMID: 34658374 PMCID: PMC8514226 DOI: 10.15644/asc55/3/5] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 08/25/2021] [Indexed: 11/25/2022] Open
Abstract
Objectives The aim of this clinical study was to compare tooth sensitivity scores and color change values before and 1 day following whitening treatments using different concentrations of whitening agents for in-office and at-home procedures. Materials and methods A total of 60 participants divided into 3 groups were included in this study. A whitening procedure was carried out in groups using 40% hydrogen peroxide (HP) in in-office treatment, 16% and 10% carbamide peroxide (CP), respectively. Participants rated their tooth sensitivity at the baseline and 1 day following the treatment. The CIElab values were recorded and color differences were calculated. Results Within each of the whitening treatments, the tooth sensitivity scores significantly increased following the procedure (p<0.05). The largest significant increase in scores was noted in 40% HP in-office whitening treatment, while the lowest increase was noted in 10% CP at-home whitening treatments (p<0.05). The highest color change 1 day following the procedure was found in the 40% HP in-office whitening treatment group (3.3) and it significantly differed from both 16% CP and 10% CP at-home whitening treatments whose color difference was both 2.0, respectively (p<0.05). Conclusion 1 day following the procedure, a low concentrate CP agent for at-home whitening causes the least tooth sensitivity compared to higher concentrate CP for at-home and HP for in-office agents, with the same color change efficacy as higher concentrate CP agent. In case with slight tooth sensitivity reported at the baseline, a 10% CP whitening treatment should be recommended.
Collapse
Affiliation(s)
- Amar Piknjač
- - Private dental office Floss Gloss, Sarajevo, Bosnia and Herzegovina
| | - Mirko Soldo
- - Dental practice, Community Health Center Osječko-baranjska County, Osijek, Croatia
| | - Davor Illeš
- - Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| | - Dubravka Knezović Zlatarić
- - Department of Removable Prosthodontics, School of Dental Medicine, University of Zagreb, Zagreb, Croatia
| |
Collapse
|
7
|
Orilisi G, Tosco V, Monterubbianesi R, Notarstefano V, Özcan M, Putignano A, Orsini G. ATR-FTIR, EDS and SEM evaluations of enamel structure after treatment with hydrogen peroxide bleaching agents loaded with nano-hydroxyapatite particles. PeerJ 2021; 9:e10606. [PMID: 33575125 PMCID: PMC7849511 DOI: 10.7717/peerj.10606] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Accepted: 11/28/2020] [Indexed: 01/04/2023] Open
Abstract
Background Tooth whitening is one of the most requested dental treatments, but it still presents some side effects. Indeed, the bleaching agent can generate patients’ discomfort and dental hard tissue damages, not achieving an efficient and long-lasting treatment with optimum whitening effect. To overcome these limitations, the bleaching agents containing nano-hydroxyapatite can represent a reliable solution to avoid these detrimental effects. Methods In this study, human third molars were treated with commercial bleaching agents, containing nano-hydroxyapatite (nHA) and 6% (at-home treatment), 12% and 18% (in-office treatments) of hydrogen peroxide (HP), named respectively G1, G2 and G3. The results were evaluated descriptively and analytically using Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR), Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray spectroscopy (EDS), comparing the treated groups with a commercial gel containing 10% carbamide peroxide (CONV) and with a non-treated control group (CTRL). Results ATR-FTIR analysis revealed a similar composition in carbonates and phosphates for CTRL, G1 and G2 groups, which showed no significant differences in their spectral profiles; an increased amount of organic matter was found in G3, while CONV displayed an intermediate behavior. SEM analysis did not highlight significant changes in the enamel microstructure of G1 and CONV when compared to CTRL; the pattern observed in G2 presented a slight increase of enamel irregularities, while G3 displayed a partial removal of the aprismatic layer and microporosities. No evident effects due to nHA were observed in the structure of the hydroxyapatite component of G1, G2 and CONV, if compared to CTRL, while G3 showed a slight loss of crystallinity. In all groups, EDS identified slight changes in the concentration of chemical elements O and Ca, while the Ca/P ratio was similar when compared to CTRL. Conclusion The obtained results suggest that the application of the tested commercial bleaching agents, with a concentration of HP up to 12%, does not alter the morphological and chemical composition of the enamel surface and maintains its crystallinity.
Collapse
Affiliation(s)
- Giulia Orilisi
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Vincenzo Tosco
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Riccardo Monterubbianesi
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Valentina Notarstefano
- Department of Life and Environmental Sciences, Polytechnic University of Marche, Ancona, Italy
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center for Dental and Oral Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Zurich, Switzerland
| | - Angelo Putignano
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| | - Giovanna Orsini
- Department of Clinical Sciences and Stomatology, Polytechnic University of Marche, Ancona, Italy
| |
Collapse
|
8
|
Kury M, Moura Antonialli F, S. Soares LE, Pereira Machado Tabchoury C, Giannini M, Esteban Florez FL, Cavalli V. Effects of violet radiation and nonthermal atmospheric plasma on the mineral contents of enamel during in-office dental bleaching. Photodiagnosis Photodyn Ther 2020; 31:101848. [DOI: 10.1016/j.pdpdt.2020.101848] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 04/13/2020] [Accepted: 05/26/2020] [Indexed: 10/24/2022]
|
9
|
Kury M, Wada EE, Silva DPD, Tabchoury CPM, Giannini M, Cavalli V. Effect of violet LED light on in-office bleaching protocols: a randomized controlled clinical trial. J Appl Oral Sci 2020; 28:e20190720. [PMID: 32428059 PMCID: PMC7213781 DOI: 10.1590/1678-7757-2019-0720] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Accepted: 03/24/2020] [Indexed: 11/30/2022] Open
Abstract
Objective This study evaluated the clinical effect of violet LED light on in-office bleaching used alone or combined with 37% carbamide peroxide (CP) or 35% hydrogen peroxide (HP). Methodology A total of 100 patients were divided into five groups (n=20): LED, LED/CP, CP, LED/HP and HP. Colorimetric evaluation was performed using a spectrophotometer (ΔE, ΔL, Δa, Δb) and a visual shade guide (ΔSGU). Calcium (Ca)/phosphorous (P) ratio was quantified in the enamel microbiopsies. Measurements were performed at baseline (T 0 ), after bleaching (T B ) and in the 14-day follow-up (T 14 ). At each bleaching session, a visual scale determined the absolute risk (AR) and intensity of tooth sensitivity (TS). Data were evaluated by one-way (ΔE, Δa, ΔL, Δb), two-way repeated measures ANOVA (Ca/P ratio), and Tukey post-hoc tests. ΔSGU and TS were evaluated by Kruskal-Wallis and Mann-Whitney, and AR by Chi-Squared tests (a=5%). Results LED produced the lowest ΔE (p<0.05), but LED/HP promoted greater ΔE, ΔSGU and Δb (T 14 ) than HP (p<0.05). No differences were observed in ΔE and ΔSGU for LED/CP and HP groups (p>0.05). ΔL and Δa were not influenced by LED activation. After bleaching, LED/CP exhibited greater Δb than CP (p>0.05), but no differences were found between these groups at T 14 (p>0.05). LED treatment promoted the lowest risk of TS (16%), while HP promoted the highest (94.4%) (p<0.05). No statistical differences of risk of TS were found for CP (44%), LED/CP (61%) and LED/HP (88%) groups (p>0.05). No differences were found in enamel Ca/P ratio among treatments, regardless of evaluation times. Conclusions Violet LED alone produced the lowest bleaching effect, but enhanced HP bleaching results. Patients treated with LED/CP reached the same efficacy of HP, with reduced risk and intensity of tooth sensitivity and none of the bleaching protocols adversely affected enamel mineral content.
Collapse
Affiliation(s)
- Matheus Kury
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| | - Erica Eiko Wada
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| | - Daylana Pacheco da Silva
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| | - Cínthia Pereira Machado Tabchoury
- Departamento de Ciências Fisiológicas, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| | - Marcelo Giannini
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| | - Vanessa Cavalli
- Departamento de Odontologia Restauradora, Faculdade de Odontologia de Piracicaba, Universidade Estadual de Campinas, Piracicaba, SP, Brasil
| |
Collapse
|
10
|
Martins LM, Lima e Souza LA, Sutil E, da Silva LM, Silva JOS, Reis A, Loguercio AD. Clinical Effects of Desensitizing Prefilled Disposable Trays in In-office Bleaching: A Randomized Single-blind Clinical Trial. Oper Dent 2020; 45:E1-E10. [DOI: 10.2341/18-149-c] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
This study aimed to evaluate the desensitizing effect of a prefilled disposable tray containing potassium nitrate and fluoride on the self-reported tooth sensitivity (TS) and the bleaching efficacy of 40% hydrogen peroxide bleaching agent used for in-office bleaching in comparison with potassium nitrate and fluoride gel applied in a conventional-delivered tray system in an equivalence clinical trial.
Methods and Materials:
Seventy-eight patients, with a right maxillary canine darker than A3, were selected for this single-blind (evaluators), randomized clinical trial. Teeth were bleached in two sessions with a one-week interval in between. Before in-office bleaching, the prefilled disposable tray or conventional tray containing potassium nitrate and fluoride was used for 15 minutes. Subsequently, the bleaching agent was applied in two 20-minute applications (per the manufacturer's directions) in each session. The color change was evaluated by subjective (Vita Classical and Vita Bleachedguide) and objective (Easyshade Advance Spectrophotometer) methods at baseline and 30 days after the first bleaching session. TS was recorded for up to 48 hours using a 0-10 visual analog scale. The absolute risk was evaluated by chi-square test, while the intensity of TS was evaluated by McNemar test (α=0.05). Color change in shade guide units and ΔE was analyzed by Student t-test for independent samples (α=0.05).
Results:
Significant whitening was observed in both groups after 30 days of clinical evaluation. The use of different methods of desensitizer in a tray did not influence the absolute risk and intensity of TS (p>0.05), although a tendency of lower risk of TS with the prefilled disposable tray containing potassium nitrate and fluoride was observed.
Conclusion:
The use of a prefilled disposable tray containing potassium nitrate and fluoride before the application of the in-office bleaching product did not affect the whitening degree and decreased self-reported TS when compared with a conventional-delivered tray system.
Collapse
Affiliation(s)
- LM Martins
- Leandro de Moura Martins, DDS, Ms, PhD, professor, Faculdade de Odontologia, Universidade Federal do Amazonas, Manaus, Brazil
| | - LA Lima e Souza
- Larissa Alves Lima e Souza, DDS, MS, Faculdade de Odontologia, Universidade Federal do Amazonas, Manaus, Brazil
| | - E Sutil
- Elisama Sutil, DDS, Ms student, University Estadual de Ponta Grossa, Restorative Dentistry, Ponta Grossa, Brazil
| | - LM da Silva
- Luciana Mendonça da Silva, DDS, PhD, professor, Faculdade de Odontologia, Universidade Federal do Amazonas, Manaus, Brazil
| | - JOS Silva
- Luciana Mendonça da Silva, DDS, PhD, professor, Faculdade de Odontologia, Universidade Federal do Amazonas, Manaus, Brazil
| | - A Reis
- Alessandra Reis, DDS, PhD, professor, State University of Ponta Grossa, Restorative Dentistry, Ponta Grossa, Brazil
| | - AD Loguercio
- Alessandro D Loguercio, DDS, Ms, PhD, professor, State University of Ponta Grossa, Restorative Dentistry, Ponta Grossa, Brazil. Professor, Faculdad de Ciencias de la Salud Eugenio Espejo, University UTE, Quito, Ecuador
| |
Collapse
|
11
|
Torres CRG, Zanatta RF, Silva TJ, Borges AB. Effect of Calcium and Fluoride Addition to Hydrogen Peroxide Bleaching Gel On Tooth Diffusion, Color, and Microhardness. Oper Dent 2019; 44:424-432. [DOI: 10.2341/18-113-l] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
The aim of this study was to evaluate the effect of calcium and fluoride addition to a 35% hydrogen peroxide (HP) bleaching gel with regard to its diffusion through the tooth structure, enamel microhardness, and bleaching efficacy.
Methods and Materials:
Eighty specimens (6 mm in diameter and 2 mm in height; 1 mm/enamel and 1 mm/dentin) were obtained from bovine incisors that were polished and divided into four groups (n=20) according to the remineralizing agent added to the gel: Ca = 0.5% calcium gluconate; F = 0.2% sodium fluoride; Ca+F = 0.5% calcium gluconate and 0.2% sodium fluoride; and control = no agent. Initial microhardness and color were assessed. The samples were positioned over simulated pulpal chambers filled with acetate buffer solution to capture the HP. Gels were applied over enamel for 30 minutes, and HP diffusion was assessed by spectrophotometry two hours after bleaching. Microhardness was measured immediately after bleaching and then the specimens were immersed into artificial saliva for seven days for final color assessment. Data were analyzed by one-way analysis of variance followed by Tukey test.
Results:
Bleaching reduced microhardness for all groups (p=0.0001), but the Ca+F and F groups showed lower reductions after bleaching. The addition of Ca, F, and Ca+F decreased the peroxide penetration through the tooth structure (p=0.0001), but there were no differences in color change for ΔL (p=0.357), Δa (p=0.061), Δb (p=0.823), and ΔE (p=0.581).
Conclusion:
The addition of calcium and fluoride in the gel did not affect bleaching efficacy, but it was able to reduce both the peroxide diffusion and the bleached enamel microhardness loss.
Collapse
Affiliation(s)
- CRG Torres
- Carlos RG Torres, DDS, PhD, associate professor, Institute of Science and Technology, São Paulo State University–UNESP, São José dos Campos, São Paulo, Brazil; Restorative Dentistry, São José dos Campos, São Paulo, Brazil
| | - RF Zanatta
- Rayssa Ferreira Zanatta, DDS, MS, PhD, Institute of Science and Technology, São Paulo State University–UNESP; Restorative Dentistry, São José dos Campos, São Paulo, Brazil
| | - TJ Silva
- Tatiane Josefa Silva, DDS, Institute of Science and Technology, São Paulo State University–UNESP, São José dos Campos, São Paulo, Brazil; Restorative Dentistry, São José dos Campos, São Paulo, Brazil
| | - AB Borges
- Alessandra B Borges, DDS, PhD, associate professor, Institute of Science and Technology, São Paulo State University–UNESP, Restorative Dentistry, São José dos Campos, São Paulo, Brazil
| |
Collapse
|
12
|
Pinto A, Bridi EC, Amaral F, França F, Turssi CP, Pérez CA, Martinez EF, Flório FM, Basting RT. Enamel Mineral Content Changes After Bleaching With High and Low Hydrogen Peroxide Concentrations: Colorimetric Spectrophotometry and Total Reflection X-ray Fluorescence Analyses. Oper Dent 2018; 42:308-318. [PMID: 28467252 DOI: 10.2341/16-032-l] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the calcium (Ca) and phosphorous (P) content in enamel bleached with high and low concentrations of hydrogen peroxide (HP) using Total Reflection X-Ray Fluorescence (TXRF) and colorimetric spectrophotometry (SPEC). Forty-eight sound human third molars were used. Their roots were embedded in polystyrene resin and immersed for seven days in an artificial saliva solution. Then they were distributed into six groups to receive the bleaching treatments. The agents of high HP concentration (for in-office use) evaluated were Whiteness HP Maxx/FGM (35% HP), Whiteness HP Blue/FGM (35% HP, 2% calcium gluconate), Pola Office+/SDI (37.5% HP, 5% potassium nitrate), and Opalescence Boost/Ultradent (38% HP, 1.1% ion fluoride, 3% potassium nitrate); these agents were applied to enamel in three sessions. The agents of low HP concentration (for home use) evaluated were Pola Day/SDI (9.5% HP) and White Class 10%/FGM (10% HP, potassium nitrate, calcium, fluoride), and these agents were applied for 14 days. Enamel microbiopsies were evaluated by TXRF and SPEC analysis before the bleaching treatment (baseline), during the treatment, and 14 days after the end of the treatment. For TXRF, the Kruskal-Wallis test showed that Ca and P were not influenced by agent (p>0.05). For SPEC, Pola Office+, Opalescence Boost, Pola Day, and White Class 10% caused a decrease of Ca over time; there was a significant decrease of P over time to Pola Office+ and White Class 10%. The Spearman test showed no correlation between the Ca (p=0.987; r2=-0.020) and P (p=0.728, r2=0.038) obtained by SPEC and TXRF. For TXRF and SPEC, changes in Ca and P during bleaching occurred independently of the HP concentration used.
Collapse
|
13
|
Diniz A, Lima S, Tavarez RR, Borges AH, Pinto S, Tonetto MR, Loguercio AD, Bandéca MC. Preventive Use of a Resin-based Desensitizer Containing Glutaraldehyde on Tooth Sensitivity Caused by In-office Bleaching: A Randomized, Single-blind Clinical Trial. Oper Dent 2018; 43:472-481. [PMID: 29570018 DOI: 10.2341/17-020-c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE To evaluate the risk and intensity of bleaching-induced tooth sensitivity (TS) after in-office bleaching following topical application of a resin-based glutaraldehyde desensitizer. METHODS Thirty-three patients were randomly assigned to the experimental (Gluma Desensitizer Liquid, Heraeus Kulzer, Hanau, Germany) and placebo groups. The placebo or Gluma Desensitizer Liquid was applied for one minute prior to application of an in-office bleaching gel. Bleaching was performed with 35% hydrogen peroxide gel (three applications × 15 minutes each) over two sessions, one week apart. The color of the anterior teeth was evaluated before and 21 days after treatment using the VITA Classical shade guide, Bleachedguide 3D, and Easyshade spectrophotometer. TS during and after the bleaching was recorded according to the visual analog (VAS) and numerical rating (NRS) scales. All data were submitted to statistical analysis (α=0.05). RESULTS There was no significant difference in absolute risk or intensity of TS between the two groups (risk and VAS, p=0.93 and 0.31, respectively; NRS, p≥0.45). At the end of the bleaching protocol, tooth whitening was observed in both groups, as evident from color change in shade guide units (ΔSGU, 4.1-7.1; both guides) and overall color change (ΔE, 7.4-9.3 units); however, there were no significant differences in whitening between the two groups ( p>0.11). CONCLUSION Gluma Desensitizer Liquid was not able to reduce the risk or intensity of TS. Bleaching efficacy was not affected by application of the desensitizer.
Collapse
|
14
|
Grazioli G, Valente LL, Isolan CP, Pinheiro HA, Duarte CG, Münchow EA. Bleaching and enamel surface interactions resulting from the use of highly-concentrated bleaching gels. Arch Oral Biol 2018; 87:157-162. [DOI: 10.1016/j.archoralbio.2017.12.026] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 12/21/2017] [Accepted: 12/27/2017] [Indexed: 10/18/2022]
|
15
|
de Geus JL, Wambier LM, Kossatz S, Loguercio AD, Reis A. At-home vs In-office Bleaching: A Systematic Review and Meta-analysis. Oper Dent 2016; 41:341-56. [PMID: 27045285 DOI: 10.2341/15-287-lit] [Citation(s) in RCA: 116] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE A systematic review and meta-analysis were performed to evaluate the risk and intensity of tooth sensitivity during in-office and at-home bleaching in adult patients. The efficacy of dental bleaching was also evaluated. METHODS A comprehensive search was performed in the MEDLINE via PubMed, Scopus, Web of Science, Latin American and Caribbean Health Sciences Literature database, Brazilian Library in Dentistry, Cochrane Library, and System for Information on Grey Literature in Europe without restrictions. The annual conference of the International Association for Dental Research abstracts (1990-2014) and unpublished and ongoing trials registry were also searched. Dissertations and theses were searched using the ProQuest Dissertations and Periódicos Capes Theses databases. Only randomized clinical trials that compared the prevalence or intensity of tooth sensitivity during in-office and at-home bleaching in adult patients were included and studies that evaluated the efficacy of these dental bleaching techniques, in terms of shade guide units (ΔSGU) and in terms of color difference measured with a spectrophotometer (ΔE*). RESULTS After the removal of duplicates, 1139 articles were identified. After title and abstract screening, 29 studies remained. Fifteen studies were further excluded, whereas 12 studies remained for qualitative analyses and 8 for the meta-analysis of the primary and secondary outcomes. No significant difference in the risk/intensity of tooth sensitivity or in bleaching efficacy was observed in the present study. CONCLUSION In an overall comparison of at-home and in-office bleaching, no differences were detected, either regarding risk/intensity of tooth sensitivity or the effectiveness of the bleaching treatment. This comparison, however, does not take into consideration variations in the protocols (daily usage time, number of bleaching sessions, and product concentration) of the bleaching techniques in the studies included.
Collapse
|
16
|
Yu D, Gao S, Min J, Zhang Q, Gao S, Yu H. Nanotribological and Nanomechanical Properties Changes of Tooth After Bleaching and Remineralization in Wet Environment. NANOSCALE RESEARCH LETTERS 2015; 10:463. [PMID: 26625887 PMCID: PMC4666889 DOI: 10.1186/s11671-015-1167-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2015] [Accepted: 11/22/2015] [Indexed: 02/05/2023]
Abstract
Teeth bleaching cases had increased with people's desire for oral aesthetic; however, bleached teeth would still undertake chewing actions and remineralizing process in saliva. Nanotribological and nanomechanical properties are proper displays for dental performance of bleached teeth. The purpose of the research was to reveal the effect of bleaching and remineralization on the nanotribological and nanomechanical properties of teeth in wet environment. The specimens were divided into four groups according to the bleaching products used: 12 % hydrogen peroxide (HP) (12HP group); 15 % carbamide peroxide (CP) (15CP group); 35 % CP (35CP group); and artificial saliva (control group). The nanotribological and nanomechanical property changes of tooth enamel after bleaching and remineralization were evaluated respectively by nanoscratch and nanoindentation tests in wet environment, imitating the wet oral environment. The morphology changes were evaluated by statistical parametric mapping (SPM) and scanning electron microscopy (SEM). After bleaching, 12HP group and 15CP group showed increased scratch depth with more pile ups on the scratch edges, decreased nanohardness, and corroded surface appearance. While the 35CP group showed an increase in nanoscratch depth, no change in nanohardness and surface appearance was observed. The control group showed no change in these measurements. After remineralization, the three bleaching groups showed decreased nanoscratch depth and no change of nanohardness compared with the bleached teeth. And the control group showed no changes in nanotribological and nanomechanical properties. The nanotribological and nanomechanical properties of the 12HP group and 15CP group were affected by bleaching, but the nanotribological properties recovered partly and the nanomechanical properties got no change after 1 week of remineralization. As for the 35CP group, the nanotribological properties were influenced and the nanomechanical properties were not affected. These results remind us of taking actions to protect our teeth during bleaching.
Collapse
Affiliation(s)
- Dandan Yu
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Shanshan Gao
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jie Min
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Qianqian Zhang
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Shuai Gao
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China.
| |
Collapse
|
17
|
Loguercio AD, Tay LY, Herrera DR, Bauer J, Reis A. Effectiveness of nano-calcium phosphate paste on sensitivity during and after bleaching: a randomized clinical trial. Braz Oral Res 2015; 29:1-7. [PMID: 26313348 DOI: 10.1590/1807-3107bor-2015.vol29.0099] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2014] [Accepted: 04/23/2015] [Indexed: 11/22/2022] Open
Abstract
The study aimed to evaluate the effectiveness of in-office bleaching and associated tooth sensitivity on application of nano-calcium phosphate paste as desensitizing agent. Bleaching was performed with 35% hydrogen peroxide gel in 40 patients who were randomly divided into placebo and nano-calcium phosphate paste groups. Bleaching efficacy (BE) was evaluated using a value-oriented Vita shade guide. Tooth sensitivity was recorded using a numeric rating scale (0-4) during bleaching and up to 48 h after each session. The primary outcome of absolute risk of tooth sensitivity was compared using the Fisher's exact test (α = 0.05). The intensity of tooth sensitivity and the efficacy of in-office bleaching were also statistically evaluated. No significant differences in absolute risk and intensity of tooth sensitivity were detected between the groups (p = 1.0 and p = 0.53, respectively). BE was also found to be similar between the groups (p = 0.67). Although the use of a nano-calcium phosphate paste associated with fluoride and potassium nitrate did not influence the whitening outcome, but it also did not reduce bleaching-induced tooth sensitivity.
Collapse
Affiliation(s)
- Alessandro Dourado Loguercio
- Department of Restorative Dentistry, School of Dentistry, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, BR
| | - Lidia Yileng Tay
- Department of Restorative Dentistry, Universidad Peruana Cayetano Heredia, Lima, PE
| | - Daniel Rodrigo Herrera
- Department of Restorative Dentistry, School of Dentistry of Piracicaba, University of Campinas, Piracicaba, SP, BR
| | - Jose Bauer
- Department of Dentistry I, School of Dentistry, Universidade Federal do Maranhão, São Luís, MA, BR
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, Universidade Estadual de Ponta Grossa, Ponta Grossa, PR, BR
| |
Collapse
|
18
|
de Moraes IQS, Silva LNDB, Porto ICCDM, de Lima Neto CF, Dos Santos NB, Fragoso LSDM. Effect of in-office bleaching with 35% hydrogen peroxide with and without addition of calcium on the enamel surface. Microsc Res Tech 2015; 78:975-81. [PMID: 26279091 DOI: 10.1002/jemt.22561] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2015] [Revised: 07/04/2015] [Accepted: 07/26/2015] [Indexed: 11/08/2022]
Abstract
This study aimed to evaluate effectiveness and effects of bleaching with 35% hydrogen peroxide with and without calcium on color, micromorphology, and the replacement of calcium and phosphate on the enamel surface. Thirty bovine enamel blocks (5.0 × 5.0 mm) were placed into the following groups: G1: artificial saliva (control); G2: 35% hydrogen peroxide gel without calcium (Whiteness HP Maxx-FGM); and G3: 35% hydrogen peroxide gel with calcium (Whiteness HP Blue-FGM). Three color measurements were performed with a spectrophotometer: untreated (baseline), after performing staining, and after application of bleaching agents. Calcium deposition on the enamel was evaluated before and after the application of bleaching agents using energy-dispersive X-ray spectrometry. The enamel surface micromorphology was observed under scanning electron microscopy. The pH of each product was measured. The data were subjected to one-factor analysis of variance (ANOVA), and any differences were analyzed using Tukey's test (P < 0.05). G3 showed greater variation in total color after the experiment than G2 and G1; there was no significant difference in calcium or phosphorus concentration before and after the experimental procedures; morphological changes were observed only in G2 and G3; and the pH values of the Whiteness HP Maxx and Whiteness HP Blue bleaching agents were 5.77 and 7.79, respectively. The 35% hydrogen peroxide with calcium showed greater bleaching potential, but the addition of calcium had no effect in terms of reducing morphological changes or increasing the calcium concentration on the enamel surface.
Collapse
Affiliation(s)
- Izadora Quintela Souza de Moraes
- School of Dentistry, Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| | - Lucas Nunes de Brito Silva
- School of Dentistry, Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| | - Isabel Cristina Celerino de Moraes Porto
- Department of Restorative Dentistry, School of Dentistry, Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| | - Cantídio Francisco de Lima Neto
- Laboratório LEAP, Instituto De Química E Biotecnologia (IQB), Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| | - Natanael Barbosa Dos Santos
- Department of Cariology, School of Dentistry, Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| | - Larissa Silveira de Mendonça Fragoso
- Department of Restorative Dentistry, School of Dentistry, Federal University of Alagoas, Campus AC Simões, Av. Lourival Melo Mota, S/N, Tabuleiro Do Martins, CEP: 57072-970, Maceió, Alagoas, Brazil
| |
Collapse
|
19
|
Klaric E, Rakic M, Sever I, Milat O, Par M, Tarle Z. Enamel and Dentin Microhardness and Chemical Composition After Experimental Light-activated Bleaching. Oper Dent 2015; 40:E132-41. [PMID: 25748206 DOI: 10.2341/14-148-l] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To evaluate 1) the influence of five bleaching agents (with additional light activation) on enamel and dentin surface microhardness and chemical composition and 2) the remineralizing potential of artificial saliva and amorphous calcium phosphate (ACP). METHODS AND MATERIALS The study was conducted on 125 human third molars dissected into quarters for separate enamel and dentin measurements. The bleaching process was performed with 38% and 25% hydrogen peroxide (HP) and 30%, 16%, and 10% carbamide peroxide (CP) gels two times for 15 minutes each time. All bleaching gels were tested alone and in combination with ZOOM2, light-emitting diode (LED), organic LED, and femtosecond laser. A total of 25 bleaching combinations (n=10) were evaluated. Microhardness was measured by a Vickers diamond. Chemical analysis was performed using energy-dispersive X-ray spectroscopy. RESULTS Bleaching agents used in the absence of light activation caused a significant reduction in enamel and dentin surface microhardness (p<0.001), ranging from 8% for 16% CP to 40% for 25% HP. The effects of different light activations were negligible. After two-week treatment with ACP and artificial saliva, maximum deviation from baseline microhardness was just 3%. Such treatment increased the concentrations of calcium, phosphorus, and fluorine. CONCLUSIONS An increase in peroxide concentration and gel acidity negatively affected microhardness and concentrations of calcium and phosphorus in enamel and dentin. ACP and artificial saliva stimulated the remineralization of hard tissues.
Collapse
|
20
|
Féliz-Matos L, Hernández LM, Abreu N. Dental Bleaching Techniques; Hydrogen-carbamide Peroxides and Light Sources for Activation, an Update. Mini Review Article. Open Dent J 2015; 8:264-8. [PMID: 25646134 PMCID: PMC4311381 DOI: 10.2174/1874210601408010264] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2014] [Revised: 10/19/2014] [Accepted: 11/17/2014] [Indexed: 11/22/2022] Open
Abstract
Hydrogen and carbamide peroxides have been successfully used for many years; in the past century the dental bleaching technique suffered several changes and almost 10 years before new millennium the technique was finally recognized by the international agencies of regulation. It is important that Dentists handle the peroxides with the essential knowledge, because it is demonstrated that satisfactory final results of this technique depend on the correct diagnosis of stains, management of the substrates (enamel and dentin) and as well sensitivity. Dentists are exposed to several dental bleaching techniques, products and brands, and in the last 2 decades the devices for light activation of the peroxides have become an extensive catalog. Today, the technique is also suffering changes based on the effectiveness of the different light sources for peroxide activation and its relation to satisfactory final results of the technique. The purpose of this literature review is to explain the determinant factors that influence satisfactory final results of the techniques and provide a general overview, in order to achieve a treatment decision based on evidence.
Collapse
Affiliation(s)
- Leandro Féliz-Matos
- Department of Academic Research/School of Dentistry, Universidad Iberoamericana, UNIBE. Santo Domingo, Dominican Republic
| | - Luis Miguel Hernández
- Department of Academic Research/School of Dentistry, Universidad Iberoamericana, UNIBE. Santo Domingo, Dominican Republic
| | - Ninoska Abreu
- Department of Academic Research/School of Dentistry, Universidad Iberoamericana, UNIBE. Santo Domingo, Dominican Republic
| |
Collapse
|
21
|
Borges AB, Zanatta RF, Barros ACSM, Silva LC, Pucci CR, Torres CRG. Effect of hydrogen peroxide concentration on enamel color and microhardness. Oper Dent 2014; 40:96-101. [PMID: 25136902 DOI: 10.2341/13-371-l] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the effect of hydrogen peroxide gels with different concentrations (20%, 25%, 30%, and 35%) on enamel Knoop microhardness (KNH) as well as on changes in dental color (C). METHODS Cylindrical specimens of enamel/dentin (3-mm diameter and 2-mm thickness) were obtained from bovine incisors and randomly divided into six groups (n=20), according to the concentration of the whitening gel (20%, 25%, 30%, 35%, control, thickener). After polishing, initial values of KNH0 and color measurement, assessed by spectrophotometry using the CIE L*a*b* system, were taken from the enamel surface. The gels were applied on the enamel surface for 30 minutes, and immediate values of KNHi were taken. After seven days of being stored in artificial saliva, new measures of KNH7 and color (L7* a7* b7*, for calculating ΔE, ΔL, and Δb) were made. Data were submitted to statistical analysis of variance, followed by Tukey test (p<0.05). RESULTS Differences in gel concentration and time did not influence the microhardness (p=0.54 and p=0.29, respectively). In relation to color changes, ΔE data showed that the 35% gel presented a higher color alteration than the 20% gel did (p=0.006). CONCLUSION Bleaching with 35% hydrogen peroxide gel was more effective than with the 20% gel, without promoting significant adverse effects on enamel surface microhardness.
Collapse
|
22
|
Parreiras SO, Vianna P, Kossatz S, Loguercio AD, Reis A. Effects of light activated in-office bleaching on permeability, microhardness, and mineral content of enamel. Oper Dent 2014; 39:E225-30. [PMID: 24815914 DOI: 10.2341/13-031-l] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The aim of this study was to evaluate the permeability (PE), microhardness (KHN), and mineral change in enamel after LED/laser activated in-office bleaching. For PE, the coronal portion of premolars (n=51) was subjected to bleaching with 35% hydrogen peroxide (Whiteness HP Maxx, FGM Dental Products, Joinville, SC, Brazil). The samples were stained via the histochemical method, which involves a copper sulphate solution and rubeanic acid. The penetration of dye into the enamel was measured. The KHN of enamel was assessed before treatment, immediately after the bleaching treatment, and again after one week. The calcium and phosphorus content were analyzed with a scanning electron microscope with energy-dispersive X-ray (JSM 6360LV, Jeol Ltd, Tokyo, Japan). The data set from each test was subjected to appropriate parametric statistical analysis (α=0.05). No significant differences were observed for PE in NLA and LA compared to the control group (p=0.98), as well as for calcium (p=0.16) and phosphorus (p=0.80) content. Significant reduction of KHN after bleaching occurred for both groups (p<0.001). After immersion in artificial saliva, the KHN of the enamel for all groups was similar to that seen before bleaching. Light activation during in-office bleaching does not produce significant changes in the enamel compared to a non-light-activated technique.
Collapse
|