1
|
Guo X, Xing H, Pan H, Wang Y, Chen W, Wang H, Zhang X, Liu J, Xu N, Wang Y, Ma W. Neuronavigation Combined With Intraoperative Ultrasound and Intraoperative Magnetic Resonance Imaging Versus Neuronavigation Alone in Diffuse Glioma Surgery. World Neurosurg 2024:S1878-8750(24)01654-1. [PMID: 39343380 DOI: 10.1016/j.wneu.2024.09.105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2024] [Revised: 09/19/2024] [Accepted: 09/20/2024] [Indexed: 10/01/2024]
Abstract
OBJECTIVE This study aimed to integrate intraoperative ultrasound and magnetic resonance imaging (IMRI) with neuronavigation (NN) to create a multimodal surgical protocol for diffuse gliomas. Clinical outcomes were compared to the standard NN-guided protocol. METHODS Adult patients with diffuse gliomas scheduled for gross total resection (GTR) were consecutively enrolled to undergo either NN-guided surgery (80 patients, July 2019-January 2022) or multimodal-integrated surgery (80 patients, February 2022-August 2023). The primary outcomes were the extent of resection (EOR) and GTR. Additional outcomes included operative time, blood loss, length of hospital stay, and patient survival. RESULTS GTR was achieved in 69% of patients who underwent multimodal-integrated surgery, compared to 43% of those who received NN-guided surgery (P = 0.002). Residual tumor was detected by IMRI in 53 patients (66%), and further GTR was achieved in 28 of these cases. The median EOR was 100% for the multimodal group and 95% for the NN-guided group (P = 0.001), while the median operative time was 8 hours versus 5 hours (P < 0.001). Neurological deficits, blood loss, and hospital stay durations were comparable between 2 groups. Multimodal-integrated surgery resulted in greater EOR and higher GTR rates in contrast-enhancing gliomas, gliomas in eloquent regions, and large gliomas (≥50 mm). GTR in glioblastomas and other contrast-enhancing gliomas contributed to improved overall survival. CONCLUSIONS Compared to standard NN-guided surgery, multimodal-integrated surgery using NN, IMRI, and intraoperative ultrasound significantly increased the EOR and GTR rates for diffuse gliomas.
Collapse
Affiliation(s)
- Xiaopeng Guo
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; China Anti-Cancer Association Specialty Committee of Glioma, Peking Union Medical College Hospital, Beijing, China
| | - Hao Xing
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Huiru Pan
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yuekun Wang
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Wenlin Chen
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Hai Wang
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xin Zhang
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jiahui Liu
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Nan Xu
- Department of Anesthesia, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Yu Wang
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; China Anti-Cancer Association Specialty Committee of Glioma, Peking Union Medical College Hospital, Beijing, China.
| | - Wenbin Ma
- Department of Neurosurgery, Center for Malignant Brain Tumors, and National Glioma MDT Alliance, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; China Anti-Cancer Association Specialty Committee of Glioma, Peking Union Medical College Hospital, Beijing, China
| |
Collapse
|
2
|
Karmarkar R, Benjafield A, Aroori S. The Role of Colour Segmented Fluorescence (CSF) Mode and Same-day Administration of Low-dose Indocyanine Green in Liver Surgery: Our Initial Experience : Indocyanine Green Fluorescence Guided Resection of Liver Tumours. J Fluoresc 2024; 34:2133-2138. [PMID: 37713013 DOI: 10.1007/s10895-023-03434-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 09/05/2023] [Indexed: 09/16/2023]
Abstract
Indocyanine green (ICG) fluorescence image guidance (I-FIGS) is increasingly used in liver surgery. Several regimens have been described regarding the optimum timing and dose of administration. This study presents our early experience with utilising monochromatic Colour Segmented Fluorescence (CSF)-mode and same-day administration of low-dose-ICG in the resection of liver tumours. Between November 2020 and March 2022, I-FIGS was used in 15 patients with suspected liver tumours. ICG was administered intravenously at 0.02 to 0.05 mg/kg dose 2-3 h before surgery. ICG camera was switched to CSF-grey-scale mode to visualise the tumour and to avoid the interference of the green background liver. Using the SPY-CSF mode, the image was scaled to near-infra-red (NIR) fluorescence intensity to accurately identify the tumours and resection margins. Fifteen patients (eight males) with a median age of 71 years (range: 36-86) underwent I-FIGS. Of these, 67% underwent laparoscopic liver surgery, 78% had non-anatomical resections, and 33% underwent redo liver surgery. The mean tumour size was 40.6 mm (SD+/-41 mm). The median number of tumours was two (1-7). All colorectal liver metastases (CRLM) had a signet ring appearance. Hepatocellular carcinomas (HCC) showed partial fluorescence. Tumours were well/moderately differentiated, with CRLM in 86% and HCC in two patients. The R0 resection rate was 72%. In our experience, low-dose-ICG administered at least 2-3 h before surgery can identify liver tumours and their margins in CSF-grey-scale mode. Further research is needed to evaluate its role in reducing R1 resection rates and surgical outcomes.
Collapse
Affiliation(s)
- Rahi Karmarkar
- Peninsula HPB Unit, University Hospitals Plymouth NHS Trust & University of Plymouth, Plymouth, UK
- Doctoral College, Faculty of Health, University of Plymouth, Plymouth, UK
| | - Anastasia Benjafield
- Peninsula HPB Unit, University Hospitals Plymouth NHS Trust & University of Plymouth, Plymouth, UK
| | - Somaiah Aroori
- Peninsula HPB Unit, University Hospitals Plymouth NHS Trust & University of Plymouth, Plymouth, UK.
| |
Collapse
|
3
|
Rubio-García JJ, Mantilla Pinilla AJ, Gil Sánchez S, Villodre Tudela C, Alcázar López C, Melgar Requena P, Rodríguez Laiz G, Irurzun López J, Ramia-Ángel JM. Onyx®, A New Tool for Intraoperative Localization of Liver Lesions. Surg Innov 2024; 31:220-223. [PMID: 38387870 DOI: 10.1177/15533506241236732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2024]
Abstract
BACKGROUND Precise preoperative localization of liver tumors facilitates successful surgical procedures, Intraoperative ultrasonography is a sensitive imaging modality. However, the presence of small non-palpable isoechoic intraparenchymal lesions may be challenging intraoperatively. METHODOLOGY AND MATERIAL DESCRIPTION Onyx® is a non-adhesive liquid agent comprised of ethylene-vinyl alcohol usually used dissolved in dimethyl-sulfoxide and suspended micronized tantalum powder to provide contrast for visualization under fluoroscopy and ultrasonography and a macroscopic black shape. This embolization material has been increasingly used for the embolization of intracranial arteriovenous malformations. We present the novel application of Onyx® on liver surgery. CURRENT STATUS We present the case of a female, 55 years-old, whose medical history revealed an elective sigmoidectomy (pT3N1a). After 17 months of follow up, by PET-CT scan, the patient was diagnosed of a small intraparenchymal hypo-attenuated 13 mm tumor located at segment V consistent with metachronous colorectal liver metastasis. Open metastasectomy was performed, ultrasonography-guided Onyx® infusion was delivered the day after, intraoperative ultrasonography showed a palpable hyperechoic material with a posterior acoustic shadowing artifact around the lesion. Onyx® is a promising new tool, without any previous application on liver surgery, feasible with advantages in small not palpable intraparenchymal liver lesions.
Collapse
Affiliation(s)
- J J Rubio-García
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| | - A J Mantilla Pinilla
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
- Servicio de Radiodiagnóstico y Radiología Intervencionista, Hospital General Universitario de Alicante, Alicante, Spain
| | - S Gil Sánchez
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
- Servicio de Radiodiagnóstico y Radiología Intervencionista, Hospital General Universitario de Alicante, Alicante, Spain
| | - C Villodre Tudela
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| | - C Alcázar López
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| | - P Melgar Requena
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| | - G Rodríguez Laiz
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| | - J Irurzun López
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
- Servicio de Radiodiagnóstico y Radiología Intervencionista, Hospital General Universitario de Alicante, Alicante, Spain
| | - J M Ramia-Ángel
- Servicio de Cirugía General y Aparato Digestivo, Hospital General Universitario de Alicante, Alicante, Spain
- Instituto de Investigación Sanitaria y Biomédica de Alicante (ISABIAL), Alicante, Spain
| |
Collapse
|
4
|
Wise PA, Studier-Fischer A, Nickel F, Hackert T. [Status Quo of Surgical Navigation]. Zentralbl Chir 2023. [PMID: 38056501 DOI: 10.1055/a-2211-4898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/08/2023]
Abstract
Surgical navigation, also referred to as computer-assisted or image-guided surgery, is a technique that employs a variety of methods - such as 3D imaging, tracking systems, specialised software, and robotics to support surgeons during surgical interventions. These emerging technologies aim not only to enhance the accuracy and precision of surgical procedures, but also to enable less invasive approaches, with the objective of reducing complications and improving operative outcomes for patients. By harnessing the integration of emerging digital technologies, surgical navigation holds the promise of assisting complex procedures across various medical disciplines. In recent years, the field of surgical navigation has witnessed significant advances. Abdominal surgical navigation, particularly endoscopy, laparoscopic, and robot-assisted surgery, is currently undergoing a phase of rapid evolution. Emphases include image-guided navigation, instrument tracking, and the potential integration of augmented and mixed reality (AR, MR). This article will comprehensively delve into the latest developments in surgical navigation, spanning state-of-the-art intraoperative technologies like hyperspectral and fluorescent imaging, to the integration of preoperative radiological imaging within the intraoperative setting.
Collapse
Affiliation(s)
- Philipp Anthony Wise
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Universitätsklinikum Heidelberg, Heidelberg, Deutschland
| | - Alexander Studier-Fischer
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Universitätsklinikum Heidelberg, Heidelberg, Deutschland
| | - Felix Nickel
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Deutschland
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Universitätsklinikum Heidelberg, Heidelberg, Deutschland
| | - Thilo Hackert
- Klinik für Allgemein-, Viszeral- und Thoraxchirurgie, Universitätsklinikum Hamburg-Eppendorf, Hamburg, Deutschland
| |
Collapse
|
5
|
Schauer MI, Jung EM, Platz Batista da Silva N, Akers M, Loch E, Markowiak T, Piler T, Larisch C, Neu R, Stroszczynski C, Hofmann HS, Ried M. Intraoperative Contrast-Enhanced Ultrasonography (Io-CEUS) in Minimally Invasive Thoracic Surgery for Characterization of Pulmonary Tumours: A Clinical Feasibility Study. Cancers (Basel) 2023; 15:3854. [PMID: 37568670 PMCID: PMC10417103 DOI: 10.3390/cancers15153854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 07/19/2023] [Accepted: 07/27/2023] [Indexed: 08/13/2023] Open
Abstract
BACKGROUND The intraoperative detection of solitary pulmonary nodules (SPNs) continues to be a major challenge, especially in minimally invasive video-assisted thoracic surgery (VATS). The location, size, and intraoperative frozen section result of SPNs are decisive regarding the extent of lung resection. This feasibility study investigates the technical applicability of intraoperative contrast-enhanced ultrasonography (Io-CEUS) in minimally invasive thoracic surgery. METHODS In this prospective, monocentric clinical feasibility study, n = 30 patients who underwent Io-CEUS during elective minimally invasive lung resection for SPNs between October 2021 and February 2023. The primary endpoint was the technical feasibility of Io-CEUS during VATS. Secondary endpoints were defined as the detection and characterization of SPNs. RESULTS In all patients (female, n = 13; mean age, 63 ± 8.6 years) Io-CEUS could be performed without problems during VATS. All SPNs were detected by Io-CEUS (100%). SPNs had a mean size of 2.2 cm (0.5-4.5 cm) and a mean distance to the lung surface of 2.0 cm (0-6.4 cm). B-mode, colour-coded Doppler sonography, and contrast-enhanced ultrasound were used to characterize all tumours intraoperatively. Significant differences were found, especially in vascularization as well as in contrast agent behaviour, depending on the tumour entity. After successful lung resection, a pathologic examination confirmed the presence of lung carcinomas (n = 17), lung metastases (n = 10), and benign lung tumours (n = 3). CONCLUSIONS The technical feasibility of Io-CEUS was confirmed in VATS before resection regarding the detection of suspicious SPNs. In particular, the use of Doppler sonography and contrast agent kinetics revealed intraoperative specific aspects depending on the tumour entity. Further studies on Io-CEUS and the application of an endoscopic probe for VATS will follow.
Collapse
Affiliation(s)
- Martin Ignaz Schauer
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Ernst-Michael Jung
- Institute for Radiology, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany; (N.P.B.d.S.); (M.A.); (C.S.)
| | - Natascha Platz Batista da Silva
- Institute for Radiology, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany; (N.P.B.d.S.); (M.A.); (C.S.)
| | - Michael Akers
- Institute for Radiology, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany; (N.P.B.d.S.); (M.A.); (C.S.)
| | - Elena Loch
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Till Markowiak
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Tomas Piler
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Christopher Larisch
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Reiner Neu
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Christian Stroszczynski
- Institute for Radiology, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany; (N.P.B.d.S.); (M.A.); (C.S.)
| | - Hans-Stefan Hofmann
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| | - Michael Ried
- Department of Thoracic Surgery, University Medical Center Regensburg, Franz-Josef-Strauss-Allee 11, 93053 Regensburg, Germany (T.P.); (C.L.); (H.-S.H.); (M.R.)
| |
Collapse
|
6
|
Chang GY, Fetzer DT, Porembka MR. Contrast-Enhanced Intraoperative Ultrasound of the Liver. Surg Oncol Clin N Am 2022; 31:707-719. [PMID: 36243503 DOI: 10.1016/j.soc.2022.06.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Contrast-enhanced intraoperative ultrasound (CE-IOUS) is a relatively new but valuable tool that is increasingly used as an adjunct to computed tomography, MRI, and IOUS for patients undergoing liver surgery. CE-IOUS has an important role in 2 main settings: the discrimination of indeterminate lesions detected in cirrhotic livers by conventional IOUS and in the detection of colorectal liver metastasis that may be overlooked by other imaging modalities. The intraoperative nature of the imaging and interpretation allows for CE-IOUS to directly affect surgical decision-making that may importantly affect patient outcomes.
Collapse
Affiliation(s)
- Gloria Y Chang
- Division of Surgical Oncology, Department of Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390, USA
| | - David T Fetzer
- Department of Radiology, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, E6-230-BF, Dallas, TX 75390-9316, USA
| | - Matthew R Porembka
- Division of Surgical Oncology, Department of Surgery, Dedman Family Scholar in Clinical Care, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, NB2.340, Dallas, TX 75390, USA.
| |
Collapse
|
7
|
Mogahed M, Zytoon AA, Abdel Haleem A, Imam E, Ghanem N, Abdellatif WM. The value of intra-operative ultrasonography on safety margin and outcome during liver resection and radio-frequency ablation in the management of hepatocellular carcinoma patients. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [DOI: 10.1186/s43055-021-00567-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Hepatocellular carcinoma (HCC) is an important health issue worldwide. Liver resection is the optimal management for early compensated HCC patients, but the majority of HCC patients are not candidates for resection. Several nonsurgical treatment modalities such as radio-frequency ablation (RFA), microwave ablation (MWA), trans-arterial chemoembolization, and immune therapy have been established. Intra-operative ultrasound (IOUS) is essential for accurate staging and secures both resection and RFA. We aimed to detect the value of using IOUS on safety margin and outcome during liver resection and RFA in the management of HCC patients. In the current study, 76 HCC patients, 58 males and 18 females, were included. Patients' age ranged from 49 to 69 years. Patients were divided into two groups: 52 open surgery liver resections (open resection group) and 24 laparoscopic-assisted RFA guided with laparoscopic IOUS (LARFA group). The open resection group was further subdivided into 32 cases for whom IOUS was performed and 20 patients studied retrospectively without IOUS. Surgical decisions were based on preoperative ultrasonography, computed tomography, and/or magnetic resonance imaging (MRI). We determined the size, number of lesions, and location by IOUS and compared them with preoperative imaging. Histopathology was done for resected lesions and follow-up CT for all patients.
Results
In the open resection group, the 32 cases of 52 for whom IOUS was performed, all had free surgical margin (100%) while 18 of 20 patients studied retrospectively without IOUS had free surgical margin (90%). Patients operated guided by IOUS had less morbidity and mortality with less operative time and hospital stay. In the LARFA group (24 patients with 37 lesions), the one-month follow-up showed complete ablation for all lesions in the 24 patients, while 12-month follow-up proved two cases of recurrence.
Conclusions
IOUS is a cornerstone in liver surgery. It improves outcomes with less morbidity and mortality and helps to achieve free surgical margin. Using IOUS allows the performance of radical but conservative hepatic resection.
Collapse
|
8
|
Xu YW, Fu H. Application of intraoperative ultrasound in liver surgery. Hepatobiliary Pancreat Dis Int 2021; 20:501-502. [PMID: 34417143 DOI: 10.1016/j.hbpd.2021.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Accepted: 07/20/2021] [Indexed: 02/05/2023]
Affiliation(s)
- Ya-Wei Xu
- Department of Hepatobiliary Surgery, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing 312000, China
| | - Hong Fu
- Department of Hepatobiliary Surgery, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University, Shaoxing 312000, China.
| |
Collapse
|
9
|
Platz Batista da Silva N, Engeßer M, Hackl C, Brunner S, Hornung M, Schlitt HJ, Evert K, Stroszczynski C, Jung EM. Intraoperative Characterization of Pancreatic Tumors Using Contrast-Enhanced Ultrasound and Shear Wave Elastography for Optimization of Surgical Strategies. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:1613-1625. [PMID: 33124700 DOI: 10.1002/jum.15545] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 08/31/2020] [Accepted: 09/22/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To evaluate intraoperative contrast-enhanced ultrasound (IoCEUS) and intraoperative shear wave elastography (IoSWE) for characterization of focal pancreatic lesions (FPLs) in correlation with postoperative histologic results. Thereby, the impact of intraoperative ultrasound (US) on pancreas surgery was evaluated. METHODS Intraoperative CEUS and SWE data from 54 patients, who underwent pancreas surgery between 2017 and 2019, were analyzed retrospectively. Ultrasound examinations were performed with multifrequency linear/T-shaped transducers (3-9 MHz) on a high-end US device (LOGIQ E9; GE Healthcare, Chicago, IL). To analyze FPL stiffness by SWE, regions of interest were placed to measure the shear wave speed (meters per second) and stiffness (kilopascals). After intravenous bolus injections of 2.4 to 10 mL of sulfur hexafluoride microbubbles, a dynamic analysis of FPL microvascularization from arterial to late phases was performed using IoCEUS considering hypoenhancement/irregular vascularization of macrocystic/small solid FPL malignancy criteria. Ultrasound findings were correlated with postoperative histologic results. The impact of intraoperative US on surgery was documented in each case. RESULTS Of 54 FPLs, IoCEUS could correctly characterize 39 of 39 malignant and 6 of 15 benign FPLs; IoSWE 29 of 39 as malignant and 7 of 15 as benign. Intraoperative CEUS's sensitivity was 100%; specificity, 40%; accuracy, 83.3%; positive predictive value, 81.3%; and negative predictive value, 100% (P < .05). Applying cutoff values of 3 m/s and 28.7 kPa, SWE's sensitivity was 74.4%; specificity, 46.7%; accuracy, 66.7%; positive predictive value; 78.4%; and negative predictive value, 41.2% for cancer detection (P < .05). The combined use of both techniques showed an accuracy rate of 76%, sensitivity of 74.4%, and specificity of 33.3%. In 29.6%, US results had an immediate impact on surgery. CONCLUSIONS Intraoperative SWE and CEUS are highly valuable techniques for intraoperative characterization of FPLs. Although IoCEUS proved to be superior to IoSWE, the combined use can be helpful in particular cases.
Collapse
Affiliation(s)
| | - Maria Engeßer
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - Christina Hackl
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Stefan Brunner
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Matthias Hornung
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Hans J Schlitt
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - Katja Evert
- Department of Pathology, University Hospital Regensburg, Regensburg, Germany
| | | | - Ernst Michael Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
10
|
Osei-Bordom DC, Kamarajah S, Christou N. Colorectal Cancer, Liver Metastases and Biotherapies. Biomedicines 2021; 9:894. [PMID: 34440099 PMCID: PMC8389538 DOI: 10.3390/biomedicines9080894] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 07/13/2021] [Accepted: 07/21/2021] [Indexed: 12/01/2022] Open
Abstract
(1) Background: colorectal cancer (CRC) is one of the deadliest causes of death by cancer worldwide. Its first main metastatic diffusion spreads to the liver. Different mechanisms such as the epithelial-mesenchymal transition and angiogenesis are the characteristics of this invasion. At this stage, different options are possible and still in debate, especially regarding the use of targeted therapeutics and biotherapies. (2) Methods: A review of the literature has been done focusing on the clinical management of liver metastasis of colorectal cancer and the contribution of biotherapies in this field. (3) Results: In a clinical setting, surgeons and oncologists consider liver metastasis in CRC into two groups to launch adapted therapeutics: resectable and non-resectable. Around these two entities, the combination of targeted therapies and biotherapies are of high interest and are currently tested to know in which molecular and clinical conditions they have to be applied to impact positively both on survival and quality of life of patients.
Collapse
Affiliation(s)
- Daniel-Clement Osei-Bordom
- Department of General Surgery, Queen Elizabeth Hospital, University Hospitals Birmingham, Birmingham B15 2TH, UK; (D.-C.O.-B.); (S.K.)
- Institute of Immunology and Immunotherapy, University of Birmingham, Birmingham B15 2TT, UK
- NIHR Birmingham Biomedical Research Centre, Centre for Liver and Gastroenterology Research, University of Birmingham, Birmingham B15 2TT, UK
| | - Sivesh Kamarajah
- Department of General Surgery, Queen Elizabeth Hospital, University Hospitals Birmingham, Birmingham B15 2TH, UK; (D.-C.O.-B.); (S.K.)
| | - Niki Christou
- Department of General Surgery, Queen Elizabeth Hospital, University Hospitals Birmingham, Birmingham B15 2TH, UK; (D.-C.O.-B.); (S.K.)
- Department of General Surgery, University Hospital of Limoges, 87000 Limoges, France
- EA3842 CAPTuR Laboratory “Cell Activation Control, Tumor Progression and Therapeutic Resistance”, Faculty of Medicine, 2 Rue du Docteur Marcland, 87025 Limoges, France
| |
Collapse
|
11
|
Ogrinc N, Saudemont P, Takats Z, Salzet M, Fournier I. Cancer Surgery 2.0: Guidance by Real-Time Molecular Technologies. Trends Mol Med 2021; 27:602-615. [PMID: 33965341 DOI: 10.1016/j.molmed.2021.04.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 03/30/2021] [Accepted: 04/02/2021] [Indexed: 12/14/2022]
Abstract
In vivo cancer margin delineation during surgery remains a major challenge. Despite the availability of several image guidance techniques and intraoperative assessment, clear surgical margins and debulking efficiency remain scarce. For this reason, there is particular interest in developing rapid intraoperative tools with high sensitivity and specificity to help guide cancer surgery in vivo. Recently, several emerging technologies including intraoperative mass spectrometry have paved the way for molecular guidance in a clinical setting. We evaluate these techniques and assess their relevance for intraoperative surgical guidance and how they can transform the future of molecular cancer surgery, diagnostics, patient management and care.
Collapse
Affiliation(s)
- Nina Ogrinc
- University of Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France
| | - Philippe Saudemont
- University of Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France
| | - Zoltan Takats
- University of Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France
| | - Michel Salzet
- University of Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France; Institut Universitaire de France (IUF), Paris, France.
| | - Isabelle Fournier
- University of Lille, Inserm, CHU Lille, U1192 - Protéomique Réponse Inflammatoire Spectrométrie de Masse - PRISM, F-59000 Lille, France; Institut Universitaire de France (IUF), Paris, France.
| |
Collapse
|
12
|
Lubner MG, Mankowski Gettle L, Kim DH, Ziemlewicz TJ, Dahiya N, Pickhardt P. Diagnostic and procedural intraoperative ultrasound: technique, tips and tricks for optimizing results. Br J Radiol 2021; 94:20201406. [PMID: 33684305 DOI: 10.1259/bjr.20201406] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
Intraoperative ultrasound (IOUS) is a valuable adjunctive tool that can provide real-time diagnostic information in surgery that has the potential to alter patient management and decrease complications. Lesion localization, characterization and staging can be performed, as well as surveying for additional lesions and metastatic disease. IOUS is commonly used in the liver for hepatic metastatic disease and hepatocellular carcinoma, in the pancreas for neuroendocrine tumors, and in the kidney for renal cell carcinoma. IOUS allows real-time evaluation of vascular patency and perfusion in organ transplantation and allows for early intervention for anastomotic complications. It can also be used to guide intraoperative procedures such as biopsy, fiducial placement, radiation, or ablation. A variety of adjuncts including microbubble contrast and elastography may provide additional information at IOUS. It is important for the radiologist to be familiar with the available equipment, common clinical indications, technique, relevant anatomy and intraoperative imaging appearance to optimize performance of this valuable imaging modality.
Collapse
Affiliation(s)
- Meghan G Lubner
- University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | | | - David H Kim
- University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | | | | | - Perry Pickhardt
- University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| |
Collapse
|
13
|
Fu Y, Chen Q, Yu Z, Dong H, Li X, Chen Q, Hu B, Li H, Miao J. Clinical application of ultrasound-guided mediastinal lymph node biopsy through cervical mediastinoscopy. Thorac Cancer 2020; 12:297-303. [PMID: 33141499 PMCID: PMC7862788 DOI: 10.1111/1759-7714.13717] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/10/2020] [Accepted: 10/11/2020] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Cervical mediastinoscopy is useful for diagnosing lung and mediastinal disease. Ultrasound is a safe real-time diagnostic tool widely employed in many surgical fields. Ultrasound was used in cervical mediastinoscopy in our cohort with satisfactory results. This study investigated the safety, feasibility, and availability of video-assisted mediastinoscopy (VAM) combined with ultrasound for mediastinal lymph node biopsy. METHODS A total of 87 cases involving cervical mediastinal lymph node biopsy performed from November 2015 to May 2020, with complete clinical and pathological information, were retrospectively analyzed in the Department of Thoracic Surgery at Beijing Chaoyang Hospital. The cohort was divided into two groups: ultrasound-guided biopsy under video-assisted mediastinoscopy (UVAM) (44 cases) and routine VAM (43 cases). Operation time, biopsy number and nodal stations, postoperative complications, pathological conditions, and surgical difficulty were compared between the two nodal stations. RESULTS UVAM was significantly shorter and more lymph node specimens were obtained than with VAM. There was one case of fatal bleeding and two cases of right recurrent laryngeal nerve injury in the VAM group, and no postoperative complications in the UVAM group. CONCLUSIONS When used with cervical VAM, ultrasound guidance assists physicians assess the space between lymph nodes, surrounding tissues, and large vessels systematically, making biopsy safer and easier, improving lymph node sampling, and decreasing postoperative complications. Furthermore, surgeons can easily learn and master this method. KEY POINTS Significant findings of the study: Ultrasound was used in combination with cervical mediastinoscopy and the results showed that ultrasound guidance makes biopsy in patients safer and easier, improves lymph node sampling, and decreases postoperative complications. WHAT THIS STUDY ADDS Surgeons can easily learn and master this method.
Collapse
Affiliation(s)
- Yili Fu
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Qingshan Chen
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Zexing Yu
- Department of Ultrasound Medicine, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Honghong Dong
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Xin Li
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Qirui Chen
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Bin Hu
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Hui Li
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| | - Jinbai Miao
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
14
|
Zhang Y, Lv J, Liu P, Zhao X, Chen K, Li Q, Nie L, Fang C. Contrast-Enhanced Multispectral Photoacoustic Imaging for Irregular Hepatectomy Navigation: A Pilot Study. ACS Biomater Sci Eng 2020; 6:5874-5885. [PMID: 33320552 DOI: 10.1021/acsbiomaterials.0c00921] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Irregular hepatectomy plays a prominent role in the treatment of small hepatocellular carcinoma (HCC) patients with severe cirrhosis and localized liver metastasis. In clinical practices, intraoperative tumor boundaries delineation facilitates to accomplish tumor resection with negative margin, remarkably decreasing the recurrence rates. Currently, ultrasound (US) and ICG fluorescence-guided surgery has been used for intraoperative navigation in irregular hepatectomy, but insufficient specificity results in a limited prevalence. Inspired by the high resolution of photoacoustic (PA) imaging and established clinical efficacy of 18F-Alfatide that is specific for integrin αvβ3-overexpressed tumors, we herein developed a fluorescent analogue IR820-E[c(RGDfK)]2, and a proof-of-concept intraoperative multispectral PA imaging navigation for precise irregular hepatectomy using hand-held PA/US imaging system. An integrin αvβ3-targeted fluorescent contrast agent IR820-E[c(RGDfK)]2 was designed, synthesized, and characterized. In vitro studies were performed to determine optical and PA properties, affinity and specificity and biocompatibility. Multispectral PA imaging, the optimal imaging time point and contrast, multispectral PA imaging-guided irregular hepatectomy, pharmacokinetics, and safety profile were evaluated in subcutaneous and orthotopic HCC tumor models. Ex vivo macroscopic three-dimensions (3D) PA imaging with IR820-E[c(RGDfK)]2 staining was also performed in surgical biospecimens from patients with HCC. IR820-E[c(RGDfK)]2 has a simple synthetic method at gram scale, high affinity, and specificity for integrin αvβ3, excellent pharmacokinetic and safety profile can effectively differentiate tumor from normal liver tissues in animal models and surgical biospecimens from HCC patients. Preoperative tumor localization, intraoperative tumor boundaries delineation, and tumor excision, and postoperative negative margin assessment were successfully achieved during irregular hepatectomy. This initial attempt allows one to preoperatively detect tumor lesions, intraoperatively delineate tumor boundaries and guide tumor resection, and postoperatively evaluate tumor margin status during irregular hepatectomy. IR820-E[c(RGDfK)]2 has the potential to be an investigational new drug for clinical use in multispectral photoacoustic imaging-guided irregular hepatectomy.
Collapse
Affiliation(s)
- Yueming Zhang
- Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou 510515, P. R. China
| | - Jing Lv
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnosis & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, P. R. China
| | - Pingguo Liu
- Department of Hepatobiliary Surgery, Zhongshan Hospital Xiamen University, Xiamen 361004, P. R. China
| | - Xingyang Zhao
- Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou 510515, P. R. China
| | - Kang Chen
- Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou 510515, P. R. China
| | - Qiaolin Li
- Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou 510515, P. R. China
| | - Liming Nie
- State Key Laboratory of Molecular Vaccinology and Molecular Diagnosis & Center for Molecular Imaging and Translational Medicine, School of Public Health, Xiamen University, Xiamen 361102, P. R. China
| | - Chihua Fang
- Department of Hepatobiliary Surgery, Zhujiang Hospital, Southern Medical University, Guangzhou 510515, P. R. China
| |
Collapse
|
15
|
Wang C, Komninos C, Andersen S, D'Ettorre C, Dwyer G, Maneas E, Edwards P, Desjardins A, Stilli A, Stoyanov D. Ultrasound 3D reconstruction of malignant masses in robotic-assisted partial nephrectomy using the PAF rail system: a comparison study. Int J Comput Assist Radiol Surg 2020; 15:1147-1155. [PMID: 32385597 PMCID: PMC7316668 DOI: 10.1007/s11548-020-02149-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Accepted: 03/31/2020] [Indexed: 12/11/2022]
Abstract
Purpose In robotic-assisted partial nephrectomy (RAPN), the use of intraoperative ultrasound (IOUS) helps to localise and outline the tumours as well as the blood vessels within the kidney. The aim of this work is to evaluate the use of the pneumatically attachable flexible (PAF) rail system for US 3D reconstruction of malignant masses in RAPN. The PAF rail system is a novel device developed and previously presented by the authors to enable track-guided US scanning. Methods We present a comparison study between US 3D reconstruction of masses based on: the da Vinci Surgical System kinematics, single- and stereo-camera tracking of visual markers embedded on the probe. An US-realistic kidney phantom embedding a mass is used for testing. A new design for the US probe attachment to enhance the performance of the kinematic approach is presented. A feature extraction algorithm is proposed to detect the margins of the targeted mass in US images. Results To evaluate the performance of the investigated approaches the resulting 3D reconstructions have been compared to a CT scan of the phantom. The data collected indicates that single camera reconstruction outperformed the other approaches, reconstructing with a sub-millimetre accuracy the targeted mass. Conclusions This work demonstrates that the PAF rail system provides a reliable platform to enable accurate US 3D reconstruction of masses in RAPN procedures. The proposed system has also the potential to be employed in other surgical procedures such as hepatectomy or laparoscopic liver resection.
Collapse
Affiliation(s)
- Chongyun Wang
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - Charalampos Komninos
- Department of Electrical and Computer Engineering, University of Patras, 26504, Rio, Patras, Greece
| | - Stephanie Andersen
- Department of Computer Science, Stanford University, 353 Serra Mall, Stanford, CA, 94305, USA
| | - Claudia D'Ettorre
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - George Dwyer
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - Efthymios Maneas
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - Philip Edwards
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - Adrien Desjardins
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| | - Agostino Stilli
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK.
| | - Danail Stoyanov
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), University College London, 43-45 Foley St., Fitzrovia, London, W1W 7EJ, UK
| |
Collapse
|
16
|
|
17
|
Pace C, Nardone V, Roma S, Chegai F, Toti L, Manzia TM, Tisone G, Orlacchio A. Evaluation of Contrast-Enhanced Intraoperative Ultrasound in the Detection and Management of Liver Lesions in Patients with Hepatocellular Carcinoma. JOURNAL OF ONCOLOGY 2019; 2019:6089340. [PMID: 31467539 PMCID: PMC6701365 DOI: 10.1155/2019/6089340] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 07/04/2019] [Accepted: 07/11/2019] [Indexed: 02/07/2023]
Abstract
AIM To evaluate the role of contrast-enhanced intraoperative ultrasound (CE-IOUS) during liver surgery in the detection and management of liver lesions in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS From December 2016 to December 2017, 50 patients with HCC, who were candidates for liver resection, were evaluated with intraoperative ultrasound (IOUS). For all patients, MRI and/or CT were performed before surgery. During surgery, IOUS was performed after liver mobilization, and when nodules that had not been detected in the preoperative MRI and/or CT were observed, CE-IOUS scans were carried out with the dual purpose of better characterizing the unknown lesion and discovering new lesions. RESULTS In 12 patients, IOUS showed 14 nodules not detected by preoperative MRI and/or CT, before surgery. Out of the 12 lesions, five presented vascular features compatible with those of malignant HCC to the evaluation with CE-IOUS and four of these were simultaneously treated with intraoperative radiofrequency ablation (RFA). The fifth lesion was resected by the surgeon. The remaining nine lesions recognized by IOUS were evaluated as benign at CE-IOUS and considered regenerative nodules. The last diagnosis was confirmed during follow-up obtained by means of CT and/or MRI after 1, 3, 6, or 12 months. CONCLUSION In our experience, CE-IOUS is a useful diagnostic tool in both benign pathologies, such as regenerative nodules, and malignant liver lesions. The advantage of this approach is the possibility of intraoperatively characterizing, based on vascularization patterns, lesions that could not be diagnosed by preoperative imaging, resulting in modification of the surgical therapy decision and expansion of the resection or intraoperative ablation.
Collapse
Affiliation(s)
- Cristina Pace
- 1Department of Diagnostic and Interventional Radiology, University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Vittorio Nardone
- 1Department of Diagnostic and Interventional Radiology, University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Silvia Roma
- 1Department of Diagnostic and Interventional Radiology, University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Fabrizio Chegai
- 1Department of Diagnostic and Interventional Radiology, University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Luca Toti
- 2Department of Surgery, Liver Unit-University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Tommaso Maria Manzia
- 2Department of Surgery, Liver Unit-University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Giuseppe Tisone
- 2Department of Surgery, Liver Unit-University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| | - Antonio Orlacchio
- 1Department of Diagnostic and Interventional Radiology, University Hospital Tor Vergata, Viale Oxford 81, 00133 Rome, Italy
| |
Collapse
|
18
|
Stammes MA, Bugby SL, Porta T, Pierzchalski K, Devling T, Otto C, Dijkstra J, Vahrmeijer AL, de Geus-Oei LF, Mieog JSD. Modalities for image- and molecular-guided cancer surgery. Br J Surg 2018; 105:e69-e83. [PMID: 29341161 DOI: 10.1002/bjs.10789] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 10/25/2017] [Accepted: 11/05/2017] [Indexed: 12/19/2022]
Abstract
BACKGROUND Surgery is the cornerstone of treatment for many solid tumours. A wide variety of imaging modalities are available before surgery for staging, although surgeons still rely primarily on visual and haptic cues in the operating environment. Image and molecular guidance might improve the adequacy of resection through enhanced tumour definition and detection of aberrant deposits. Intraoperative modalities available for image- and molecular-guided cancer surgery are reviewed here. METHODS Intraoperative cancer detection techniques were identified through a systematic literature search, with selection of peer-reviewed publications from January 2012 to January 2017. Modalities were reviewed, described and compared according to 25 predefined characteristics. To summarize the data in a comparable way, a three-point rating scale was applied to quantitative characteristics. RESULTS The search identified ten image- and molecular-guided surgery techniques, which can be divided into four groups: conventional, optical, nuclear and endogenous reflectance modalities. Conventional techniques are the most well known imaging modalities, but unfortunately have the drawback of a defined resolution and long acquisition time. Optical imaging is a real-time modality; however, the penetration depth is limited. Nuclear modalities have excellent penetration depth, but their intraoperative use is limited by the use of radioactivity. Endogenous reflectance modalities provide high resolution, although with a narrow field of view. CONCLUSION Each modality has its strengths and weaknesses; no single technique will be suitable for all surgical procedures. Strict selection of modalities per cancer type and surgical requirements is required as well as combining techniques to find the optimal balance.
Collapse
Affiliation(s)
- M A Stammes
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands.,Percuros, Enschede, The Netherlands
| | - S L Bugby
- Space Research Centre, Department of Physics and Astronomy, University of Leicester, Leicester, UK
| | - T Porta
- Maastricht MultiModal Molecular Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Maastricht, The Netherlands
| | - K Pierzchalski
- Maastricht MultiModal Molecular Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Maastricht, The Netherlands
| | | | - C Otto
- Medical Cell Bio Physics, University of Twente, Enschede, The Netherlands
| | - J Dijkstra
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands
| | - A L Vahrmeijer
- Department of Surgery, Leiden University Medical Centre, Leiden, The Netherlands
| | - L-F de Geus-Oei
- Department of Radiology, Leiden University Medical Centre, Leiden, The Netherlands.,Biomedical Photonic Imaging Group, MIRA Institute, University of Twente, Enschede, The Netherlands
| | - J S D Mieog
- Department of Surgery, Leiden University Medical Centre, Leiden, The Netherlands
| |
Collapse
|
19
|
Granata V, Fusco R, Avallone A, Catalano O, Piccirillo M, Palaia R, Nasti G, Petrillo A, Izzo F. A radiologist's point of view in the presurgical and intraoperative setting of colorectal liver metastases. Future Oncol 2018; 14:2189-2206. [PMID: 30084273 DOI: 10.2217/fon-2018-0080] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Multidisciplinary management of patients with metastatic colorectal cancer requires in each phase an adequate choice of the most appropriate imaging modality. The first challenging step is liver lesions detection and characterization, using several imaging modality ultrasound, computed tomography, magnetic resonance and positron emission tomography. The criteria to establish the metastases resectability have been modified. Not only the lesions number and site but also the functional volume remnant after surgery and the quality of the nontumoral liver must be taken into account. Radiologists should identify the liver functional volume remnant and during liver surgical procedures should collaborate with the surgeon to identify all lesions, including those that disappeared after the therapy, using intraoperative ultrasound with or without contrast medium.
Collapse
Affiliation(s)
- Vincenza Granata
- Radiology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Roberta Fusco
- Radiology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Antonio Avallone
- Abdominal Oncology Division, Istitutonazionale Tumori - IRCSS - Fondazione G Pascale, Napoli, Italia
| | - Orlando Catalano
- Radiology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Mauro Piccirillo
- Hepatobiliary Surgical Oncology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Raffaele Palaia
- Hepatobiliary Surgical Oncology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Guglielmo Nasti
- Abdominal Oncology Division, Istitutonazionale Tumori - IRCSS - Fondazione G Pascale, Napoli, Italia
| | - Antonella Petrillo
- Radiology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| | - Francesco Izzo
- Hepatobiliary Surgical Oncology Division, Istitutonazionale Tumori - IRCCS - Fondazione G Pascale, Napoli, Italia
| |
Collapse
|
20
|
Contrast-Enhanced Ultrasound of the Liver: Optimizing Technique and Clinical Applications. AJR Am J Roentgenol 2017; 210:320-332. [PMID: 29220210 DOI: 10.2214/ajr.17.17843] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
OBJECTIVE The purpose of this article is to review the general principles, technique, and clinical applications of contrast-enhanced ultrasound of the liver. CONCLUSION Proper technique and optimization of contrast-enhanced ultrasound require a balance between maintaining the integrity of the microbubble contrast agent and preserving the ultrasound signal. Established and emerging applications in the liver include diagnosis of focal lesions, aiding ultrasound-guided intervention, monitoring of therapy, and aiding surgical management.
Collapse
|
21
|
Ludwig DR, Mintz AJ, Sanders VR, Fowler KJ. Liver Imaging for Colorectal Cancer Metastases. CURRENT COLORECTAL CANCER REPORTS 2017. [DOI: 10.1007/s11888-017-0391-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
22
|
Value of intraoperative ultrasound with conventional probes and its usefulness in surgical and therapeutic management of patients. RADIOLOGIA 2017. [DOI: 10.1016/j.rxeng.2017.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
23
|
da Silva NPB, Beyer L, Hottenrott M, Hackl C, Schlitt H, Stroszczynski C, Wiggermann P, Jung E. Efficiency of contrast enhanced ultrasound for immediate assessment of ablation status after intraoperative radiofrequency ablation of hepatic malignancies. Clin Hemorheol Microcirc 2017; 66:357-368. [DOI: 10.3233/ch-179112] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
| | - L.P. Beyer
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - M.C. Hottenrott
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - C. Hackl
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - H.J. Schlitt
- Department of Surgery, University Hospital Regensburg, Regensburg, Germany
| | - C. Stroszczynski
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - P. Wiggermann
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| | - E.M. Jung
- Department of Radiology, University Hospital Regensburg, Regensburg, Germany
| |
Collapse
|
24
|
Value of intraoperative ultrasound with conventional probes and its usefulness in surgical and therapeutic management of patients. RADIOLOGIA 2017; 59:516-522. [PMID: 28720469 DOI: 10.1016/j.rx.2017.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Revised: 05/31/2017] [Accepted: 06/09/2017] [Indexed: 11/24/2022]
Abstract
OBJECTIVE To prove both the reliability and the applications presented by intraoperative ultrasonography (IOUS) in surgical and therapeutic management of diverse pathologies and the possibility of doing it by using conventional equipment. MATERIAL AND METHODS Single-center retrospective study of 145 IOUS performed by using conventional equipment in 135 patients between January 2011 and June 2016. We assessed the organs studied by ultrasound, underlying conditions of patients, preoperative imaging and the degree of matching them with the histological findings. The functions of the intraoperative ultrasound were assessed in each case. RESULTS 91,7% of the scans performed were hepatic, being other locations varied but less common. They had a high concordance with the histological results of the lesions analyzed (95.4%) and in 24% of the cases their results did not coincide with those of the preoperative imaging tests, being decisive for the management of the patients. CONCLUSION Despite the limitations of our study, IOUS has proven to be a reliable and safe diagnostic test with advantages over conventional imaging techniques. It contributes to get a correct diagnosis in those lesions not characterized by the preoperative imaging tests, to locate and delimit the extension of a lesion within an organ and facilitate the performance of diagnostic procedures (intraoperative biopsy) even in centers where we do not have specific probes.
Collapse
|
25
|
Miao J, Li M, Fu Y, Hu X, Hu B, Li H. Ultrasound-Guided Video-Assisted Mediastinoscopic Biopsy: A Novel Approach. Ann Thorac Surg 2017; 102:e465-e467. [PMID: 27772612 DOI: 10.1016/j.athoracsur.2016.03.047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 03/05/2016] [Accepted: 03/14/2016] [Indexed: 12/24/2022]
Abstract
Video-assisted mediastinoscopy (VAM) is the most commonly used invasive method for the preoperative mediastinal staging of lung cancer and for the diagnosis of other mediastinal diseases. However, VAM has the risk of causing life-threatening bleeding consequent to the specific mediastinal anatomy. We adopted the ultrasonic technique for VAM biopsies that can easily distinguish the lymph nodes from the surrounding great vessels and thus makes the procedure easier and safer.
Collapse
Affiliation(s)
- Jinbai Miao
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Affiliated With Capital Medical University, Beijing, China
| | - Mei Li
- Department of Ultrasound Medicine, Beijing HaiDian Hospital, Beijing Haidian Section of Peking University Third Hospital, Beijing, China
| | - Yili Fu
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Affiliated With Capital Medical University, Beijing, China
| | - Xiaoxing Hu
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Affiliated With Capital Medical University, Beijing, China
| | - Bin Hu
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Affiliated With Capital Medical University, Beijing, China
| | - Hui Li
- Department of Thoracic Surgery, Beijing Chao-Yang Hospital, Affiliated With Capital Medical University, Beijing, China.
| |
Collapse
|
26
|
Joo I, Lee JY, Lee DH, Jeon JH, Kim H, Yi NJ, Lee KW, Suh KS. Contrast-Enhanced Ultrasound Using Perfluorobutane-Containing Microbubbles in the Assessment of Liver Allograft Damage: An Exploratory Prospective Study. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:621-628. [PMID: 28041745 DOI: 10.1016/j.ultrasmedbio.2016.11.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2016] [Revised: 11/15/2016] [Accepted: 11/21/2016] [Indexed: 06/06/2023]
Abstract
This prospective study investigated the usefulness of contrast (perfluorobutane-containing microbubbles)-enhanced ultrasound in the non-invasive assessment of liver allograft damage. Forty-one liver recipients underwent contrast-enhanced ultrasound followed by a liver biopsy. The hepatic filling rate (time between the arrival of contrast agent in the right hepatic artery and the maximum intensity of hepatic parenchyma) and parenchymal intensity difference before and after instantaneous high-power emission in the Kupffer phase were measured. Patients with allograft damage had higher hepatic filling rates and lower parenchymal intensity differences than those without damage (42.0 ± 16.9 vs. 30.5 ± 7.7 s, p = 0.005; 6.1 ± 7.4 vs. 16.6 ± 16.1 dB, p = 0.047, respectively). In the diagnosis of liver allograft damage, hepatic filling rate and parenchymal intensity difference had sensitivities of 61.5% and 90.9% and specificities of 92.6% and 63.6% using cutoffs of >38.5 s and ≤10.3 dB, respectively. In conclusion, contrast-enhanced ultrasound may be a promising tool in the detection of liver allograft damage.
Collapse
Affiliation(s)
- Ijin Joo
- Department of Radiology, Seoul National University Hospital, Seoul, Korea; Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Jae Young Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea; Department of Radiology, Seoul National University College of Medicine, Seoul, Korea; Institute of Radiation Medicine, Seoul National University Hospital, Seoul, Korea.
| | - Dong Ho Lee
- Department of Radiology, Seoul National University Hospital, Seoul, Korea; Department of Radiology, Seoul National University College of Medicine, Seoul, Korea
| | - Ju Hyeon Jeon
- Department of Radiology, Sejong General Hospital, Gyeonggi-do, Korea
| | - Hyeyoung Kim
- Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Nam-Joon Yi
- Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Kwang-Woong Lee
- Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Kyung-Suk Suh
- Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
27
|
Benzing C, Hau HM, Atanasov G, Broschewitz J, Krenzien F, Bartels M, Wiltberger G. Outcome and complications of combined liver and pancreas resections: a retrospective analysis. Acta Chir Belg 2016; 116:340-345. [PMID: 27471834 DOI: 10.1080/00015458.2016.1186962] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
BACKGROUND Combined resections of the liver and pancreas are related to high complication and mortality rates. The present study assessed the outcome of these procedures and identified specific risk factors for morbidity and mortality. METHODS Between January 2001 and April 2012, 28 combined liver/pancreas resections were performed at our institution. All patients were retrospectively analysed using a database with regards to baseline characteristics, surgical procedures, complications and survival. RESULTS Among the pancreatic resections, there were 12 (42.9%) Kausch-Whipple (KW), 9 (32.1%) pylorus-preserving pancreaticoduodenectomy (PPPD), 6 (21.4%) distal pancreatectomies (DP) and 1 (3.6%) total pancreaticoduodenectomy (TPD). In 12 (48.9%) cases, major complications (grade IIIb-V) were observed. Overall survival was 35 months (SD = 40.5) and the 3-year survival rate was 35.7% (1-year survival rate: 50%). DISCUSSION Combined resections of the liver and pancreas are associated with high complication rates, especially if major liver resections are performed. Therefore, it is mandatory to do a thorough evaluation of potential patients.
Collapse
Affiliation(s)
- Christian Benzing
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Hans-Michael Hau
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Georgi Atanasov
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Johannes Broschewitz
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Felix Krenzien
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Michael Bartels
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| | - Georg Wiltberger
- Department of Visceral, Transplantation, Vascular and Thoracic Surgery, University Hospital of Leipzig, Leipzig, Germany
| |
Collapse
|
28
|
Sastry R, Bi WL, Pieper S, Frisken S, Kapur T, Wells W, Golby AJ. Applications of Ultrasound in the Resection of Brain Tumors. J Neuroimaging 2016; 27:5-15. [PMID: 27541694 DOI: 10.1111/jon.12382] [Citation(s) in RCA: 100] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Revised: 07/04/2016] [Accepted: 07/05/2016] [Indexed: 12/23/2022] Open
Abstract
Neurosurgery makes use of preoperative imaging to visualize pathology, inform surgical planning, and evaluate the safety of selected approaches. The utility of preoperative imaging for neuronavigation, however, is diminished by the well-characterized phenomenon of brain shift, in which the brain deforms intraoperatively as a result of craniotomy, swelling, gravity, tumor resection, cerebrospinal fluid (CSF) drainage, and many other factors. As such, there is a need for updated intraoperative information that accurately reflects intraoperative conditions. Since 1982, intraoperative ultrasound has allowed neurosurgeons to craft and update operative plans without ionizing radiation exposure or major workflow interruption. Continued evolution of ultrasound technology since its introduction has resulted in superior imaging quality, smaller probes, and more seamless integration with neuronavigation systems. Furthermore, the introduction of related imaging modalities, such as 3-dimensional ultrasound, contrast-enhanced ultrasound, high-frequency ultrasound, and ultrasound elastography, has dramatically expanded the options available to the neurosurgeon intraoperatively. In the context of these advances, we review the current state, potential, and challenges of intraoperative ultrasound for brain tumor resection. We begin by evaluating these ultrasound technologies and their relative advantages and disadvantages. We then review three specific applications of these ultrasound technologies to brain tumor resection: (1) intraoperative navigation, (2) assessment of extent of resection, and (3) brain shift monitoring and compensation. We conclude by identifying opportunities for future directions in the development of ultrasound technologies.
Collapse
Affiliation(s)
- Rahul Sastry
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | - Wenya Linda Bi
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | | | - Sarah Frisken
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | - Tina Kapur
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | - William Wells
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | - Alexandra J Golby
- Department of Neurosurgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA.,Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
29
|
Ahn JH, Eom DW, Ryu DS, Park MS, Jung SM, Choi KM, Cheon GJ, Choi SJ, Jang HJ. Synchronous multicentric small hepatocellular carcinomas: defining the capsule on high-frequency intraoperative ultrasonography with pathologic correlation. Ultrasonography 2016; 35:335-44. [PMID: 27184653 PMCID: PMC5040137 DOI: 10.14366/usg.16001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 04/07/2016] [Accepted: 04/09/2016] [Indexed: 11/03/2022] Open
Abstract
PURPOSE The aim of this study was to define the capsules of synchronous multicentric small hepatocellular carcinomas (HCCs) with use of high-frequency intraoperative ultrasonography (IOUS). METHODS Among the 131 consecutive patients undergoing hepatic resection and high-frequency IOUS for HCC, 16 synchronous multicentric small HCCs in 13 patients were histologically diagnosed in the resected specimens. High-frequency IOUS and pathologic findings of these lesions were compared, with particular focus on the presence and appearance of the capsule in or around each lesion. RESULTS Synchronous multicentric small HCCs were pathologically classified into distinctly nodular (n=12) or vaguely nodular (n=4) types. All 12 distinctly nodular HCCs including six subcentimeter lesions showed detectable capsules on high-frequency IOUS and pathology. The capsules appeared as a hypoechoic rim containing hyperechoic foci (n=6), hypoechoic rim (n=5), or hyperechoic rim (n=1) with varying degrees of coverage around each lesion. Histologically, the capsules were composed of a combination of one to four layers consisting of a fibrous capsule, peritumoral fibrosis, prominent small vessels, and entrapped hepatic parenchyma. CONCLUSION Synchronous multicentric small HCCs with distinctly nodular type, even at subcentimeter size, can show capsules with varying coverage and diverse echogenicity on high-frequency IOUS.
Collapse
Affiliation(s)
- Jae Hong Ahn
- Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Dae-Woon Eom
- Department of Pathology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Dae Shick Ryu
- Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Man Soo Park
- Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Seung Mun Jung
- Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Kun Moo Choi
- Department of Surgery, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Gab Jin Cheon
- Department of Hepatology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Soo-Jung Choi
- Department of Radiology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| | - Hyuk Jai Jang
- Department of Surgery, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung, Korea
| |
Collapse
|
30
|
Xu CS, Su YJ, Xu M, Liu W, Hao P, Du LF. Correlation between blood circulation grading and angiogenesis using ultrasonic contrast of rabbit VX2 hepatic carcinoma. ASIAN PAC J TROP MED 2016; 9:153-7. [DOI: 10.1016/j.apjtm.2016.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Revised: 12/20/2015] [Accepted: 12/30/2015] [Indexed: 12/29/2022] Open
|
31
|
Hao P. Monitoring of renal ischemia reperfusion injury in rabbits by ultrasonic contrast and its relationship with expression of VEGF in renal tissue. ASIAN PAC J TROP MED 2016; 9:188-92. [PMID: 26919954 DOI: 10.1016/j.apjtm.2016.01.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2015] [Revised: 12/20/2015] [Accepted: 12/30/2015] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE To evaluate the renal ischemia reperfusion injury (IRI) in rabbits using the ultrasonic contrast technique and discuss the clinical value of ultrasonic contrast technique in the diagnosis of renal IRI by comparing the time-intensity curve of renal cortex and the expression of vascular endothelial growth factor (VEGF) of renal tissue. METHODS Twenty 3-month-old New Zealand rabbits were randomly divided into 4 groups, namely Ctrl group, IRI-12 h, IRI-24 h and IRI-48 h groups. The two dimensional gray-scale ultrasonography was employed to determine and mark the position of rabbit kidney. Rabbits were given the intraperitoneal anesthesia with 20% urethane with the dosage of 5 mL/kg. The aseptic operation was performed after the local skin disinfection in the area of both kidneys. The right kidney of animals in the control group was excised without any treatment for the left kidney. After excising the right kidney of animals in groups of IRI-12 h, IRI-24 h and IRI-48 h, the aneurysm clip was used to clip the renal pedicle vessel of left kidney, in order to simulate the ischemia. Because of the tissue ischemia, it could be seen that the color of kidney was changed from bright red to dark red, which indicated the successful modeling of ischemia. The aneurysm clip was released after one hour of maintaining the ischemia. Then the kidney turned out to be bright red from dark red, which indicated that the reperfusion was completed. Taking this moment as the time of ischemia reperfusion, the wound was stitched up. A total of 12, 24 and 36 h after the operation, the two-dimensional and color Doppler flow imaging and ultrasonic contrast were employed for the examination. The dynamic changes of ultrasonic contrast were recorded. The quantitative analysis software (QontraXt) was adopted to analyze the time-intensity curve of echo at different positions of renal cortex. After the ultrasonic contrast testing, rabbits were put to death. The renal cortex tissue was isolated and the tissue RNA and total protein were extracted respectively. Real-time PCR and western blotting were used to detect the VEGF and the Pearson product moment correlation coefficient was used to measure the linear relationship between these two variables. RESULTS The ultrasonic contrast could clearly reflect the process of IRI. The results of testing at mRNA and protein level indicated that the expression of VEGF in IRI groups was significantly increased (P < 0.05) and the expression of VEGF was also increased by the time of reperfusion. CONCLUSIONS There is the certain correlation between the expression of VEGF and process of IRI. The correlation coefficient between the ultrasonic contrast parameters of AT and TTP and the relative expression of VEGF is over 0.9, which indicates the relatively high correlation. But there is no significant difference in the change of perfusion peak intensity between groups, which has no correlation with the expression of VEGF.
Collapse
Affiliation(s)
- Peng Hao
- Department of Ultrasound, Huai'an First People's Hospital, Nanjing Medical University, Huaian 223300, Jiangsu, China.
| |
Collapse
|