1
|
Gerrard AD, Garau R, Xu W, Maeda Y, Dunlop MG, Theodoratou E, Din FVN. Repeat Faecal Immunochemical Testing for Colorectal Cancer Detection in Symptomatic and Screening Patients: A Systematic Review and Meta-Analysis. Cancers (Basel) 2024; 16:3199. [PMID: 39335170 PMCID: PMC11429846 DOI: 10.3390/cancers16183199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2024] [Revised: 09/03/2024] [Accepted: 09/10/2024] [Indexed: 09/30/2024] Open
Abstract
BACKGROUND Faecal immunochemical testing (FIT) is widely used in bowel screening programmes and assessing symptomatic patients for suspected colorectal cancer (CRC). The evidence for single test performance of FIT in both settings is considerable; however, the use of a repeat test to increase sensitivity remains uncertain. We aimed to review what increase in test positivity would be generated by additional FITs, whether a repeated FIT detects previously missed CRC and advanced colorectal neoplasia (ACRN), and to estimate the sensitivity of double-FIT strategies to diagnose CRC and ACRN. METHODS A systematic search of MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL) was performed using key search terms. Studies reporting the use of more than one FIT in the same screening round or planned assessment of a single symptomatic patient episode were included. Studies were categorised by the reported study population into asymptomatic, mixed (cohorts of combined asymptomatic, symptomatic, or high-risk surveillance), or symptomatic cohorts. RESULTS A total of 68 studies were included for analysis (39 asymptomatic, 21 mixed, 7 symptomatic, and 1 study with discrete asymptomatic and symptomatic data). At a threshold of 10 µg Hb/g, the two-test positivity ranged between 8.1 and 34.5%, with an increase from the second test of 3-9.2 percentage points. Four out of five studies comparing one versus two tests for diagnosing CRC at 10 µg Hb/g identified additional cases with the second test, with a minimum of 50% reduction in missed CRC. At a threshold of 20 µg Hb/g, the second test increased the positivity by 1.3-6.7 percentage points, with a two-test positivity of between 5.1 and 25.0%. Using a threshold of 20 µg Hb/g, five out of seven studies had a 25% reduction in missed CRC. A meta-analysis estimated the double-FIT sensitivity at 10 µg Hb/g for CRC in mixed-risk and symptomatic cohorts to be 94% and 98%, respectively. CONCLUSIONS Repeated use of FIT helps to diagnose more cases of CRC with a moderate increase in positivity. A double-FIT strategy at 10 µg Hb/g in mixed and symptomatic cohorts has a very high sensitivity for CRC.
Collapse
Affiliation(s)
- Adam D. Gerrard
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- Department of Colorectal Surgery, Western General Hospital, Edinburgh EH4 2XU, UK
| | - Roberta Garau
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- Department of Colorectal Surgery, Western General Hospital, Edinburgh EH4 2XU, UK
| | - Wei Xu
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- Centre for Global Health, Usher Institute, The University of Edinburgh, Edinburgh EH4 2XR, UK
| | - Yasuko Maeda
- School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow G12 8QQ, UK
- Department of Surgery, Queen Elizabeth University Hospital, Glasgow G51 4TF, UK
| | - Malcolm G. Dunlop
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- UK Colon Cancer Genetics Group, Medical Research Council Human Genetics Unit, Medical Research Council Institute of Genetics & Cancer, Western General Hospital, The University of Edinburgh, Edinburgh EH4 2XU, UK
| | - Evropi Theodoratou
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- Centre for Global Health, Usher Institute, The University of Edinburgh, Edinburgh EH4 2XR, UK
| | - Farhat V. N. Din
- Cancer Research UK Scotland Centre, Institute of Genetics and Cancer, The University of Edinburgh, Edinburgh EH4 2XR, UK; (A.D.G.); (E.T.)
- Department of Colorectal Surgery, Western General Hospital, Edinburgh EH4 2XU, UK
| |
Collapse
|
2
|
Farkas NG, O'Brien J, Whyte M, Jourdan I, Rockall T, Benton SC. An observational study of replicate faecal immunochemical tests in the urgently referred symptomatic cohort. Ann Clin Biochem 2023; 60:313-319. [PMID: 36864586 DOI: 10.1177/00045632231163425] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
INTRODUCTION Triage of patients with suspected colorectal cancer (CRC) utilises a single faecal immunochemical test (FIT) at a defined threshold. Limited evidence exists regarding whether replicate FIT improves the positive and negative predictive value in symptomatic patients. This study examines urgently referred symptomatic patients undergoing replicate FIT. Primary aim is to assess two FITs and CRC/serious bowel disease. Secondary aims are to determine correlation and utility of replicate FIT. METHODOLOGY Patients carried out one additional FIT during COVID-19 pandemic. FIT 1 and FIT 2 (the replicate sample) were analysed in relation to symptoms, diagnoses, investigations, future colonoscopy and missed CRC. Study period was 01/03/2020-31/07/2020. Three subgroups were compared; double positive (≥10 μg Hb/g faeces), double negative, and discordant FIT (one positive). RESULTS 111 patients had replicate FIT (50 male, 61 female). 43 (38.7%) patients had double negative, 32 (28.8%) double positive and 36 (32.4%) had discordant FITs. Median time between FITs was 14 days (IQR = 11-19). 83% of double positive patients underwent colonoscopy/virtual colonoscopy (61% in double negative patients). Six CRC and one high-risk polyp were in double positive patients (none in other groups). One discordant patient was not investigated and a CRC missed. CONCLUSIONS Replicate FIT as a triage strategy appears most effective where both FITs are negative. CRC risk is low when FIT results are discordant. Double negative FITs are reassuring given benign associated diagnoses, or for patients where endoscopic investigation is high-risk. Larger studies are required to evaluate discordant FITs, enabling refinement of urgent investigation pathways.
Collapse
Affiliation(s)
- Nicholas G Farkas
- Minimal Access Therapy and Training Unit (MATTU), Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
- Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - James O'Brien
- Minimal Access Therapy and Training Unit (MATTU), Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Martin Whyte
- Faculty of Health and Medical Sciences, University of Surrey, Guildford, UK
| | - Iain Jourdan
- Minimal Access Therapy and Training Unit (MATTU), Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Tim Rockall
- Minimal Access Therapy and Training Unit (MATTU), Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Sally C Benton
- Department of Clinical Biochemistry, Royal Surrey County Hospital, Berkshire and Surrey Pathology Services, Guildford, Surrey, UK
| |
Collapse
|
3
|
Farkas NG, Fraser CG, Maclean W, Jourdan I, Rockall T, Benton SC. Replicate and repeat faecal immunochemical tests in symptomatic patients: A systematic review. Ann Clin Biochem 2023; 60:27-36. [PMID: 35394384 DOI: 10.1177/00045632221096036] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
BACKGROUND Faecal Immunochemical tests (FITs) in the assessment of patients presenting with symptoms have generally used a single sample. Little evidence pertains to the use of replicate, where a number of tests are done prior to decision-making or repeat FIT, where additional FIT are performed following clinical decision-making. Overwhelmingly, research has focussed on FIT to help identify colorectal cancer (CRC). The aim of this review is to assess the available literature concerning replicate and repeat FIT in symptomatic patients to help generate consensus and guide future research. METHODS The terms 'faecal immunochemical test' or 'FIT' were combined with 'multiple' or 'repeat'. EMBASE, Medline and PubMed database and other searches were conducted. All papers published in English were included with no exclusion date limits until November 2021. RESULTS Of the 161 initial papers screened, seven were included for review. Qualitative and quantitative FIT outcomes were assessed in the studies. The primary aims of most related to whether replicate FIT increased diagnostic yield of CRC, with colonoscopy used as the reference standard. One publication assessed the impact of a new COVID-adapted pathway on CRC detection. No consensus on replicate FIT was apparent. Some concluded that FITs may help minimise missed CRC diagnoses: others showed no increase in diagnostic yield of CRC. CONCLUSIONS Current evidence on replicate and repeat FIT is both minimal and conflicting. FIT is a superb clinical tool, but significant gaps surrounding application remain. Further studies relating to replicate and repeat FIT are required.
Collapse
Affiliation(s)
- Nicholas G Farkas
- Minimal Access Therapy and Training Unit (MATTU), 3661Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Callum G Fraser
- Centre for Research Into Cancer Prevention and Screening, Population Health and Genomics, School of Medicine, 85326University of Dundee, Scotland, UK
| | - William Maclean
- Minimal Access Therapy and Training Unit (MATTU), 3661Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Iain Jourdan
- Minimal Access Therapy and Training Unit (MATTU), 3661Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Tim Rockall
- Minimal Access Therapy and Training Unit (MATTU), 3661Royal Surrey County Hospital NHS Foundation Trust, Guildford, UK
| | - Sally C Benton
- Department of Clinical Biochemistry, Royal Surrey County Hospital, Berkshire and Surrey Pathology Services, Guildford, UK.,NHS Bowel Cancer Screening South of England Hub, Berkshire and Surrey Pathology Services, Royal Surrey County Hospital, Guildford, UK
| |
Collapse
|
4
|
Johnstone MS, MacLeod C, Digby J, Al-Azzawi Y, Pang G, Watson AJM, Strachan J, Mowat C, McSorley ST. Prevalence of repeat faecal immunochemical testing in symptomatic patients attending primary care. Colorectal Dis 2022; 24:1498-1504. [PMID: 35776684 PMCID: PMC10084108 DOI: 10.1111/codi.16240] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 06/20/2022] [Accepted: 06/24/2022] [Indexed: 01/07/2023]
Abstract
AIM The faecal immunochemical test (FIT) for faecal haemoglobin (f-Hb) helps determine the risk of colorectal cancer (CRC) and has been integrated into symptomatic referral pathways. 'Safety netting' advice includes considering referral for persistent symptoms, but no published data exists on repeated FITs. We aimed to examine the prevalence of serial FITs in primary care and CRC risk in these patients. METHOD A multicentre, retrospective, observational study was conducted of patients with two or more consecutive f-Hb results within a year from three Scottish Health Boards which utilize FIT in primary care. Cancer registry data ensured identification of CRC cases. RESULTS Overall, 135 396 FIT results were reviewed, of which 12 359 were serial results reported within 12 months (9.1%), derived from 5761 patients. Of these, 42 (0.7%) were diagnosed with CRC. A total of 3487 (60.5%) patients had two f-Hb < 10 μg/g, 944 (16.4%) had f-Hb ≥ 10 μg/g followed by <10 μg/g, 704 (12.2%) f-Hb < 10 μg/g followed by ≥10 μg/g and 626 (10.9%) had two f-Hb ≥ 10 μg/g. The CRC rate in each group was 0.1%, 0.4%, 1.4% and 4.0%, respectively. Seven hundred and thirty four patients submitted more than two FITs within a year. The likelihood of one or more f-Hb ≥ 10 μg/g rose from 40.4% with two samples to 100% with six, while the CRC rate fell from 0.8% to 0%. CONCLUSION Serial FITs within a year account for 9.1% of all results in our Boards. CRC prevalence amongst symptomatic patients with serial FIT is lower than in single-FIT cohorts. Performing two FITs within a year for patients with persistent symptoms effectively acts as a safety net, while performing more than two within this timeframe is unlikely to be beneficial.
Collapse
Affiliation(s)
- Mark S Johnstone
- Academic Unit of Surgery, School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, UK
| | | | - Jayne Digby
- Centre for Research into Cancer Prevention and Screening, School of Medicine, Ninewells, Hospital and Medical School, University of Dundee, Dundee, UK
| | - Yassir Al-Azzawi
- Academic Unit of Surgery, School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, UK
| | - Grace Pang
- Academic Unit of Surgery, School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, UK
| | | | - Judith Strachan
- Department of Blood Sciences, Ninewells Hospital and Medical School, Dundee, UK
| | - Craig Mowat
- Population Health & Genomics, School of Medicine, Ninewells Hospital and Medical School, University of Dundee, Dundee, UK
| | - Stephen T McSorley
- Academic Unit of Surgery, School of Medicine, Dentistry and Nursing, University of Glasgow, Glasgow, UK
| |
Collapse
|
5
|
Lööv A, Högberg C, Lilja M, Theodorsson E, Hellström P, Metsini A, Olsson L. Diagnostic accuracy for colorectal cancer of a quantitative faecal immunochemical test in symptomatic primary care patients: a study protocol. Diagn Progn Res 2022; 6:16. [PMID: 35978403 PMCID: PMC9386911 DOI: 10.1186/s41512-022-00129-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 06/21/2022] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND There is increasing evidence supporting the use of faecal immunochemical tests (FIT) in patients reporting symptoms associated with colorectal cancer (CRC), but most studies until now have focused on selected subjects already referred for investigation. We therefore set out to determine the accuracy and predictive values of FIT in a primary care population. METHOD A prospective, multicentre, single-gated comparative diagnostic study on quantitative FIT in patients aged 40 years and above presenting in primary care with symptoms associated with CRC will be conducted. Patients representing the whole spectrum of severity of such symptoms met with in primary care will be eligible and identified by GPs. Participants will answer a short form on symptoms during the last month. They will provide two faecal samples from two separate days. Analyses will be performed within 5 days (QuikRead go®, Aidian Oy). The analytical working range is 10-200 μg Hb/g faeces. Reference test will be linked to the Swedish Colorectal Cancer Registry up to 2 years after inclusion. Accuracy, area under ROC curves, and predictive values will be calculated for one FIT compared to the highest value of two FIT and at cutoff < 10, 10-14.9, 15-19.9 and ≥ 20 μg Hb/g faeces. Subgroup analyses will be conducted for patients with anaemia and those reporting rectal bleeding. A model-based cost-effectiveness analysis based on the clinical accuracy study will be performed. Based on previous literature, we hypothesized that the sensitivity of the highest value of two FIT at cutoff 10 μg Hb/g faeces will be 95% (95% CI + / - 15%). The prevalence of CRC in the study population was estimated to be 2%, and the rate of non-responders to be 1/6. In all, 3000 patients will be invited at 30 primary care centres. DISCUSSION This study will generate important clinical real-life structured data on accuracy and predictive values of FIT in the most critical population for work-up of CRC, i.e. patients presenting with at times ambiguous symptoms in primary care. It will help establish the role of FIT in this large group. TRIAL REGISTRATION NCT05156307 . Registered on 14 December 2021-retrospectively registered.
Collapse
Affiliation(s)
- Anna Lööv
- Department of Medical Sciences, Örebro University, Örebro, Sweden.
- Skebäck Primary Care Centre, Region Örebro län, Örebro, Sweden.
| | - Cecilia Högberg
- Department of Public Health and Clinical Medicine, Unit of Research, Education and Development Östersund, Umeå University, Umeå, Sweden
| | - Mikael Lilja
- Department of Public Health and Clinical Medicine, Unit of Research, Education and Development Östersund, Umeå University, Umeå, Sweden
| | - Elvar Theodorsson
- Department of Biomedical and Clinical Science; Clinical Chemistry, Linköping University, Linköping, Sweden
| | - Per Hellström
- Department of Medical Sciences, Uppsala University, Uppsala, Sweden
| | - Alexandra Metsini
- Department of Medical Sciences, Örebro University, Örebro, Sweden
- Department of Knowledge Management and Patient Safety Unit, Region Värmland, Karlstad, Sweden
| | - Louise Olsson
- Department of Medical Sciences, Örebro University, Örebro, Sweden
- Centre for Assessment of Medical Technology, Örebro University Hospital, Örebro, Sweden
| |
Collapse
|
6
|
Saw KS, Liu C, Xu W, Varghese C, Parry S, Bissett I. Faecal immunochemical test to triage patients with possible colorectal cancer symptoms: meta-analysis. Br J Surg 2021; 109:182-190. [PMID: 34907419 PMCID: PMC10364725 DOI: 10.1093/bjs/znab411] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 10/31/2021] [Indexed: 12/19/2022]
Abstract
BACKGROUND This review evaluated the utility of single quantitative faecal immunochemical test (FIT) as a triaging tool for patients with symptoms of possible colorectal cancer, the effect of symptoms on FIT accuracy, and the impact of triaging incorporating FIT on service provision. METHODS Five databases were searched. Meta-analyses of the extracted FIT sensitivities and specificities for detection of colorectal cancer at reported f-Hb thresholds were performed. Secondary outcomes included sensitivity and specificity of FIT for advanced colorectal neoplasia and serious bowel disease. Subgroup analysis by FIT brand and symptoms was undertaken. RESULTS Fifteen prospective cohort studies, including 28 832 symptomatic patients were included. At the most commonly reported f-Hb positivity threshold of ≥ 10 µg Hb/g faeces (n=13), the summary sensitivity was 88.7% (95% c.i. 85.2 to 91.4) and the specificity was 80.5% (95% c.i. 75.3 to 84.8) for colorectal cancer. At lower limits of detection of ≥ 2 µg Hb/g faeces, the summary sensitivity was 96.8% (95% c.i. 91.0 to 98.9) and the specificity was 65.6% (95% c.i. 59.0 to 71.6). At the upper f-Hb positivity thresholds of ≥ 100 µg Hb/g faeces and ≥ 150 µg Hb/g faeces, summary sensitivities were 68.1% (95% c.i. 59.2 to 75.9) and 66.3% (95% c.i. 52.2 to 78.0), with specificities of 93.4% (95% c.i. 91.3 to 95.1) and 95.1% (95% c.i. 93.6 to 96.3) respectively. FIT sensitivity was comparable between different assay brands. FIT sensitivity may be higher in patients reporting rectal bleeding. CONCLUSION Single quantitative FIT at lower f-Hb positivity thresholds can adequately exclude colorectal cancer in symptomatic patients and provides a data-based approach to prioritization of colonoscopy resources.
Collapse
Affiliation(s)
- Kai Sheng Saw
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Chen Liu
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - William Xu
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Chris Varghese
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Susan Parry
- Department of Medicine, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Ian Bissett
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
7
|
James T, Nicholson BD, Marr R, Paddon M, East JE, Justice S, Oke JL, Shine B. Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care. Br J Biomed Sci 2021; 78:211-217. [PMID: 33627037 DOI: 10.1080/09674845.2021.1896204] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Introduction: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.Materials and Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.Results: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).Discussion: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.
Collapse
Affiliation(s)
- T James
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - B D Nicholson
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - R Marr
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - M Paddon
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - J E East
- Translational Gastroenterology Unit, and Oxford NIHR Biomedical Research Centre, John Radcliffe Hospital, University of Oxford, Oxford, UK
| | - S Justice
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - J L Oke
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - B Shine
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| |
Collapse
|
8
|
Benton SC, Fraser CG. Faecal immunochemical tests in the COVID-19 pandemic; safety-netting of patients with symptoms and low faecal haemoglobin concentration - can a repeat test be used? Ann Clin Biochem 2020; 58:163-165. [PMID: 33016079 DOI: 10.1177/0004563220967569] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Sally C Benton
- Clinical Biochemistry, Royal Surrey County Hospital/ NHS Bowel Cancer Screening South of England Hub, Berkshire and Surrey Pathology Services, Guildford, UK
| | - Callum G Fraser
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Ninewells Hospital and Medical School, Dundee, UK
| |
Collapse
|
9
|
Khan AA, Klimovskij M, Harshen R. Accuracy of faecal immunochemical testing in patients with symptomatic colorectal cancer. BJS Open 2020; 4:1180-1188. [PMID: 32949085 PMCID: PMC7709370 DOI: 10.1002/bjs5.50346] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Accepted: 07/23/2020] [Indexed: 01/22/2023] Open
Abstract
BACKGROUND The aim of this study was to determine the diagnostic accuracy of the faecal immunochemical test (FIT) for detecting colorectal cancer in symptomatic patients. METHODS This was a prospective study of patients with bowel symptoms. Stool samples were collected during rectal examination. The HM-JACKarc assay (Kyowa Medex, Tokyo, Japan) was used to quantify faecal haemoglobin (Hb); positive results were those with at least 10 μg Hb/g faeces. Two-by-two tables and receiver operating characteristic (ROC) curve analysis were used to determine diagnostic accuracy; χ2 and Mann-Whitney U tests were used to compare other parameters. RESULTS A total of 928 patients were included (M : F ratio 1 : 1·5; median age 72 (i.q.r. 64-80) years). The overall prevalence of colorectal cancer was 5·1 per cent. The FIT had sensitivity of 85·1 per cent, specificity of 83·5 per cent, positive predictive value of 22·6 per cent and negative predictive value of 99·0 per cent. ROC analysis of FIT for diagnosing colorectal cancer gave an area under the curve value of 0·89 (95 per cent c.i. 0·84 to 0·94). Significant bowel pathology was detected more frequently in FIT-positive patients (35·1 per cent versus 7·1 per cent in FIT-negative patients; P < 0·001). There were sex differences in FIT positivity (23·7 per cent in men versus 17·4 per cent in women; P = 0·019); the sensitivity of FIT for colorectal cancer in women was also low. False-negative FIT results were found mainly in women referred with iron-deficiency anaemia, who were found to have caecal cancer. CONCLUSION FIT effectively excluded colorectal cancer in symptomatic patients. Integration of FIT into the diagnostic pathway for colorectal cancer would direct resources appropriately to patients with a greater likelihood of having the disease.
Collapse
Affiliation(s)
- A. A. Khan
- Departments of SurgeryConquest Hospital, St Leonards‐on‐Sea, and Eastbourne District General HospitalEastbourneUK
| | - M. Klimovskij
- Departments of SurgeryConquest Hospital, St Leonards‐on‐Sea, and Eastbourne District General HospitalEastbourneUK
| | - R. Harshen
- Departments of SurgeryConquest Hospital, St Leonards‐on‐Sea, and Eastbourne District General HospitalEastbourneUK
| |
Collapse
|
10
|
Wieten E, de Klerk CM, Lansdorp-Vogelaar I, Bossuyt PM, Dekker E, Spaander MCW. A Quarter of Participants With Advanced Neoplasia Have Discordant Results From 2-Sample Fecal Immunochemical Tests for Colorectal Cancer Screening. Clin Gastroenterol Hepatol 2020; 18:1805-1811.e1. [PMID: 31563557 DOI: 10.1016/j.cgh.2019.09.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 09/15/2019] [Accepted: 09/20/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND & AIMS Some colorectal cancer (CRC) screening programs use 2-sample fecal immunochemical tests (FITs). We aimed to assess advanced neoplasia (AN) yield of 2 different FIT assays performed on the same bowel movement and have discordant results. METHODS We conducted a large prospective comparative accuracy study within the Dutch national CRC screening program to evaluate 2 quantitative FIT assays (FOB-Gold, Sentinel, Italy and OC-Sensor, Eiken, Japan) with comparable performance characteristics. We asked 42,179 screening-naïve individuals, 55-75 years old, to perform both tests on the same bowel movement, from May 2016 through March 2017. Participants with ≥1 positive test result (≥15 μg hemoglobin/gram feces) were invited for colonoscopy examination. Detection of AN by colonoscopy was the reference standard. RESULTS A total of 21,078 participants (50% participation rate) were included. FIT results were both negative for 19,032 participants (90%), both positive for 1163 participants (5.5%), and discordant for 883 participants (4.2%). AN was detected in 500 participants with 2 positive FIT results (43%) compared to 187 with discordant FIT results (21%) (p < .001). Of the 687 participants found to have AN by colonoscopy, 187 had only 1 positive FIT result (27%). CONCLUSION In a large 2-sample FIT-based CRC screening study, more than a quarter of participants in whom AN was detected by colonoscopy in the first screening round had discordant FIT results. AN was detected in one-fifth of those with FIT discordance. Participants with discordant results from 2 FITs should undergo colonoscopy. (www.trialregister.nl; no. NTR5874).
Collapse
Affiliation(s)
- Els Wieten
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Clasine M de Klerk
- Department of Gastroenterology and Hepatology, Academic Medical Center, Amsterdam, The Netherlands
| | - Iris Lansdorp-Vogelaar
- Department of Public Health, Erasmus MC University Medical Center, Rotterdam, The Netherlands
| | - Patrick M Bossuyt
- Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Academic Medical Center, Amsterdam, The Netherlands
| | - Evelien Dekker
- Department of Gastroenterology and Hepatology, Academic Medical Center, Amsterdam, The Netherlands
| | - Manon C W Spaander
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, The Netherlands.
| |
Collapse
|
11
|
Pin Vieito N, Zarraquiños S, Cubiella J. High-risk symptoms and quantitative faecal immunochemical test accuracy: Systematic review and meta-analysis. World J Gastroenterol 2019; 25:2383-2401. [PMID: 31148909 PMCID: PMC6529892 DOI: 10.3748/wjg.v25.i19.2383] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2019] [Revised: 03/20/2019] [Accepted: 03/29/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The quantitative faecal immunochemical test for haemoglobin (FIT) has been revealed to be highly accurate for colorectal cancer (CRC) detection not only in a screening setting, but also in the assessment of patients presenting lower bowel symptoms. Therefore, the National Institute for Health and Care Excellence has recommended the adoption of FIT in primary care to guide referral for suspected CRC in low-risk symptomatic patients using a 10 µg Hb/g faeces threshold. Nevertheless, it is unknown whether FIT´s accuracy remains stable throughout the broad spectrum of possible symptoms. AIM To perform a systematic review and meta-analysis to assess FIT accuracy for CRC detection in different clinical settings. METHODS A systematic literature search was performed using MEDLINE and EMBASE databases from inception to May 2018 to conduct a meta-analysis of prospective studies including symptomatic patients that evaluated the diagnostic accuracy of quantitative FIT for CRC detection. Studies were classified on the basis of brand, threshold of faecal haemoglobin concentration for a positive test result, percentage of reported symptoms (solely symptomatic, mixed cohorts) and CRC prevalence (< 2.5%, ≥ 2.5%) to limit heterogeneity and perform subgroup analysis to assess the influence of clinical spectrum on FIT´s accuracy to detect CRC. RESULTS Fifteen cohorts including 13073 patients (CRC prevalence 0.4% to 16.8%) were identified. Pooled estimates of sensitivity for studies using OC-Sensor at 10 µg Hb/g faeces threshold (n = 10400) was 89.6% [95% confidence interval (CI): 82.7% to 94.0%). However, pooled estimates of sensitivity for studies formed solely by symptomatic patients (n = 4035) and mixed cohorts (n = 6365) were 94.1% (95%CI: 90.0% to 96.6%) and 85.5% (95%CI: 76.5% to 91.4%) respectively (P < 0.01), while there were no statistically significant differences between pooled sensitivity of studies with CRC prevalence < 2.5% (84.9%, 95%CI: 73.4% to 92.0%) and ≥ 2.5% (91.7%, 95%CI: 83.3% to 96.1%) (P = 0.25). At the same threshold, OC-Sensor® sensitivity to rule out any significant colonic lesion was 78.6% (95%CI: 75.6% to 81.4%). We found substantial heterogeneity especially when assessing specificity. CONCLUSION The results of this meta-analysis confirm that, regardless of CRC prevalence, quantitative FIT is highly sensitive for CRC detection. However, FIT ability to rule out CRC is higher in studies solely including symptomatic patients.
Collapse
Affiliation(s)
- Noel Pin Vieito
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense 32005, Spain
- Instituto de Investigación Sanitaria Galicia Sur, Ourense 32005, Spain
- Department of Biochemistry, Genetics and Immunology, Faculty of Biology University of Vigo, Vigo 36310, Pontevedra, Spain
| | - Sara Zarraquiños
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense 32005, Spain
- Instituto de Investigación Sanitaria Galicia Sur, Ourense 32005, Spain
| | - Joaquín Cubiella
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense 32005, Spain
- Instituto de Investigación Sanitaria Galicia Sur, Ourense 32005, Spain
| |
Collapse
|
12
|
Mowat C, Digby J, Strachan JA, McCann R, Hall C, Heather D, Carey F, Fraser CG, Steele RJC. Impact of introducing a faecal immunochemical test (FIT) for haemoglobin into primary care on the outcome of patients with new bowel symptoms: a prospective cohort study. BMJ Open Gastroenterol 2019; 6:e000293. [PMID: 31275586 PMCID: PMC6577357 DOI: 10.1136/bmjgast-2019-000293] [Citation(s) in RCA: 65] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 03/28/2019] [Accepted: 04/01/2019] [Indexed: 12/14/2022] Open
Abstract
Objective To determine whether a faecal immunochemical test (FIT) for faecal haemoglobin concentration (f-Hb) can be safely implemented in primary care as a rule-out test for significant bowel disease (SBD) (colorectal cancer (CRC), higher risk adenoma (HRA) and inflammatory bowel disease (IBD)) when used as an adjunct to the clinical assessment of new bowel symptoms. Design Single-centre prospective cohort study of all patients who attended primary care and submitted a FIT in the first calendar year of the service beginning December 2015. f-Hb was estimated using HM-JACKarc (Kyowa Medex) with a clinical cut-off of ≥10 µg Hb/g faeces. Incident cases of CRC were verified via anonymised record linkage to the Scottish Cancer Registry. Results 5422 patients submitted 5660 FIT specimens, of which 5372 were analysed (positivity: 21.9%). 2848 patients were referred immediately to secondary care and three with f-Hb <10 µg/g presented acutely within days with obstructing CRC. 1447 completed colonoscopy in whom overall prevalence of SBD was 20.5% (95 CRC (6.6%), 133 HRA (9.2%) and 68 IBD (4.7%)); 6.6% in patients with f-Hb <10 µg/g vs 32.3% in patients with f-Hb ≥10 µg/g. One CRC was detected at CT colonoscopy. 2521 patients were not immediately referred (95.3% had f-Hb <10 µg/g) of which four (0.2%) later developed CRC. Record linkage identified no additional CRC cases within a follow-up period of 23–35 months. Conclusion In primary care, measurement of f-Hb, in conjunction with clinical assessment, can safely and objectively determine a patient’s risk of SBD.
Collapse
Affiliation(s)
- Craig Mowat
- Department of Gastroenterology, Ninewells Hospital and Medical School, Dundee, UK
| | - Jayne Digby
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| | - Judith A Strachan
- Department of Blood Sciences, Ninewells Hospital and Medical School, Dundee, UK
| | - Rebecca McCann
- Department of Blood Sciences, Ninewells Hospital and Medical School, Dundee, UK
| | | | - Duncan Heather
- Health Informatics Centre, University of Dundee, Dundee, UK
| | - Francis Carey
- Department of Pathology, Ninewells Hospital and Medical School, Dundee, UK
| | - Callum G Fraser
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| | - Robert J C Steele
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| |
Collapse
|
13
|
Turvill J, Mellen S, Jeffery L, Bevan S, Keding A, Turnock D. Diagnostic accuracy of one or two faecal haemoglobin and calprotectin measurements in patients with suspected colorectal cancer. Scand J Gastroenterol 2018; 53:1526-1534. [PMID: 30621475 DOI: 10.1080/00365521.2018.1539761] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND The role of faecal biomarkers in patients at 'high risk' of colorectal cancer (CRC) is not yet defined. Pre-analytical factors, such as heterogeneity of biomarker distribution within faeces, may influence their optimisation in clinical practice. We undertook to determine whether repeat or combined biomarker testing improves diagnostic accuracy for CRC or clinically significant disease. METHODS Patients referred with suspected CRC provided two separate faecal samples each for faecal immunochemical testing (FIT) and faecal calprotectin (FC) prior to investigation. Diagnostic accuracy of FIT and FC were evaluated based on final diagnoses. RESULTS Five hundred fifteen patients completed a full colorectal evaluation. The optimal cut-off for CRC using a single FIT was ≥12 µgHb/g faeces (84.6% sensitivity, 88.5% specificity). For two FIT, the cut-off was ≥43 µgHb/g faeces if either and ≥2 µgHb/g faeces if both were positive. There was no advantage in their diagnostic accuracy compared with a single FIT. FC had a lower diagnostic accuracy for CRC than FIT, which was not improved by repeat FC. No benefit was identified with FIT-FC combined. For CRC, significant adenomatous polyps and organic enteric disease combined, FIT and FC performed similarly to each other but were poorer predictors (AUC 0.677 and 0.660). There was no uplift in diagnostic accuracy when the tests were repeated or combined. CONCLUSION This study supports using a single FIT at a cut-off close to that recommended by NICE DG30 to improve diagnostic accuracy for 'two-week wait' patients referred with suspected CRC.
Collapse
Affiliation(s)
- James Turvill
- a Department of Gastroenterology , York Teaching Hospital NHS Foundation Trust , York , UK
| | - Samantha Mellen
- b Department of Clinical Biochemistry , York Teaching Hospital NHS Foundation Trust , York , UK
| | - Laura Jeffery
- b Department of Clinical Biochemistry , York Teaching Hospital NHS Foundation Trust , York , UK
| | - Sarah Bevan
- b Department of Clinical Biochemistry , York Teaching Hospital NHS Foundation Trust , York , UK
| | - Ada Keding
- c Department of Health Sciences, Faculty of Sciences , University of York , York , UK
| | - Daniel Turnock
- b Department of Clinical Biochemistry , York Teaching Hospital NHS Foundation Trust , York , UK
| |
Collapse
|
14
|
Fraser CG. Faecal immunochemical tests for haemoglobin (FIT) in the assessment of patients with lower abdominal symptoms: current controversies. GASTROENTEROLOGIA Y HEPATOLOGIA 2018; 42:263-270. [PMID: 30459060 DOI: 10.1016/j.gastrohep.2018.09.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2018] [Revised: 09/05/2018] [Accepted: 09/21/2018] [Indexed: 12/21/2022]
Abstract
Faecal immunochemical tests for haemoglobin (FIT), as an adjunct to clinical information, assist in the triage of patients presenting in primary care with lower abdominal symptoms. Controversy remains regarding whether and which qualitative and quantitative FIT can be used, which groups of patients would benefit most from FIT, whether FIT should be done in primary and/or secondary care, and how FIT should be incorporated into diagnostic pathways. Controversy also exists as to the optimum cut-off used for referral for colonoscopy. A single sample of faeces may be sufficient. Reporting of results requires consideration. FIT provide a good rule in test for colorectal cancer and a good rule out test for significant bowel disease, but robust safety-netting is required for patients with negative results and ongoing symptoms. Risk scoring models have been developed, but their value is unclear as yet. Further evaluation of these topics is required to inform good practice.
Collapse
Affiliation(s)
- Callum G Fraser
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Ninewells Hospital and Medical School, Dundee, Scotland, UK.
| |
Collapse
|
15
|
Auge JM, Rodriguez C, Espanyol O, Rivero L, Sandalinas S, Grau J, Jimenez W, Castells A. An evaluation of the SENTiFIT 270 analyser for quantitation of faecal haemoglobin in the investigation of patients with suspected colorectal cancer. Clin Chem Lab Med 2018; 56:625-633. [PMID: 29150989 DOI: 10.1515/cclm-2017-0605] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Accepted: 10/09/2017] [Indexed: 12/13/2022]
Abstract
BACKGROUND An evaluation of SENTiFIT® 270 (Sentinel Diagnostics, Italy; Sysmex, Spain) analyser for the quantitation of faecal haemoglobin (f-Hb) was performed. METHODS The analytical imprecision, linearity, carry over and f-Hb stability were determined. Evaluation of the diagnostic accuracy was performed on 487 patients. RESULTS Within-run and between-run imprecision ranged 1.7%-5.1% and 3.8%-6.2%, respectively. Linearity studies revealed a mean recovery of 101.1% (standard deviation, 6.7%) for all dilutions. No carry over was detected below 7650 μg Hb/g faeces. Decay of f-Hb in refrigerated samples ranged 0.2%-0.5% per day. f-Hb in patients with advanced colorectal neoplasia (ACRN) (colorectal cancer [CRC] plus advanced adenoma [AA]) were significantly higher than from those with a normal colonoscopy. Sensitivity for ACRN at f-Hb cutoffs from 10 to 60 μg Hb/g faeces ranged from 28.9% (95% confidence interval [CI], 21.7%-37.2%) to 46.5% (95% CI, 38.1%-55%), the specificity ranged from 85% (95% CI, 82.3%-87.3%) to 93.2% (95% CI, 91.2%-94.8%), positive predictive values for detecting CRC and AA ranged from 11.6% (95% CI, 7.6%-17.2%) to 20.6% (95% CI, 13.3%-30.3%) and from 34.7% (95% CI, 28.1%-42%) to 42.3% (95% CI, 32.4%-52.7%), respectively, and the negative predictive value for ACRN ranged from 90.2% (95% CI, 87.9%-92.2%) to 88.4% (95% CI, 86%-90.4%). Using two samples per patient sensitivity increased with a slight decrease in specificity. CONCLUSIONS The analytical and clinical performances of SENTiFIT assay demonstrate a specific and accurate test for detecting ACRN in symptomatic patients and those undergoing surveillance.
Collapse
Affiliation(s)
- Josep M Auge
- Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Center, Hospital Clinic, C/Villarroel 170, 08036 Barcelona, Spain
| | - Cristina Rodriguez
- Gastroenterology Department, Hospital Clinic, University of Barcelona, Barcelona, Spain; and IDIBAPS, CIBERehd, Barcelona, Spain
| | - Oihana Espanyol
- Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Center, Hospital Clinic, Barcelona, Spain
| | - Liseth Rivero
- Gastroenterology Department, Hospital Clinic, University of Barcelona, Barcelona, Spain; and IDIBAPS, CIBERehd, Barcelona, Spain
| | - Silvia Sandalinas
- Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Center, Hospital Clinic, Barcelona, Spain
| | - Jaume Grau
- Unit of Evaluation, Support and Prevention, Hospital Clinic, Barcelona, Spain
| | - Wladimiro Jimenez
- Biochemistry and Molecular Genetics Department, Biomedical Diagnostic Center, Hospital Clinic, Barcelona, Spain
| | - Antoni Castells
- Gastroenterology Department, Hospital Clinic, University of Barcelona, Barcelona, Spain; and IDIBAPS, CIBERehd, Barcelona, Spain
| |
Collapse
|
16
|
Herrero JM, Vega P, Salve M, Bujanda L, Cubiella J. Symptom or faecal immunochemical test based referral criteria for colorectal cancer detection in symptomatic patients: a diagnostic tests study. BMC Gastroenterol 2018; 18:155. [PMID: 30359225 PMCID: PMC6203209 DOI: 10.1186/s12876-018-0887-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2018] [Accepted: 10/16/2018] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND Symptom based referral criteria for colorectal cancer (CRC) detection are the cornerstone of the strategy to improve prognosis in CRC. In 2017, the National Institute for Health and Care Excellence (NICE) updated their referral criteria (2017 NG12). Recently, several studies have evaluated the faecal haemoglobin (f-Hb) concentration in this setting. The aim of this study is to evaluate the diagnostic accuracy of the 2017 NG12 referral criteria and to compare them with the CG27 referral criteria, the f-Hb concentration and two f-Hb based prediction model: COLONPREDICT and FAST Score. METHODS This is a post-hoc diagnostic test study performed within the COLONPREDICT study database (1572 patients, CRC prevalence 13.6%). We assessed symptoms, the 2017 NG12 and CG27 referral criteria and determined the f-Hb before performing a colonoscopy. We compared the discriminatory ability using the area under the curve (AUC) and the sensitivity and specificity at pre-stablished thresholds with the McNemar's test. RESULTS The 2017 NG12 referral criteria discriminatory ability (AUC 0.53; 95% confidence interval- CI 0.49-0.57) was inferior to the CG27 version (AUC 0.59; 95% CI 0.55-0.63; p = 0.01), the f-Hb concentration (AUC 0.86; 95% CI 0.84-0-89; p < 0.001), the COLONPREDICT Score (AUC 0.92; 95% CI 0.91-0.94; p < 0.001) or the FAST Score (AUC 0.87; 95% CI 0.85-0.89; p < 0.001). The number of patients meeting each criteria were as follows: 2017 NG12 and CG27 = 94.1% and 52.2%; f-Hb ≥20 and ≥ 10 μg/g faeces = 38.6 and 44.3%; COLONPREDICT Score ≥ 5.6 and ≥ 3.2 = 29.4 and 63.2% and FAST Score ≥ 4.50 and ≥ 2.12 = 37.1 and 87.0%. The 2017 NG12 criteria were more sensitive (100%) than the CG27 criteria (68.2%), the f-Hb (≥20 μg/g) (91.2%), the f-Hb (≥10 μg/g) (93.5%), the COLONPREDICT Score (≥5.6) (90.1%) and the FAST Score (≥4.50) (89.8%) (p ≤ 0.001) and equivalent to the COLONPREDICT Score (≥3.5) (99.5%) or the FAST Score (≥2.12) (100.0%) (p = 1). However, their specificity (6.8%) was significantly lower than any of the evaluated criteria (50.3%, 69.6%, 63.4%, 78.7%, 45.8%, 71.3%, 13.9%; p < 0.001). CONCLUSION Referral criteria based on f-Hb measurement, either as a single test or within prediction models, are more accurate than symptom-based referral criteria for CRC detection in symptomatic patients.
Collapse
Affiliation(s)
- Jesús-Miguel Herrero
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense, Spain.,Instituto de Investigación Biomédica Galicia Sur, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd),, Ourense, Spain
| | - Pablo Vega
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense, Spain.,Instituto de Investigación Biomédica Galicia Sur, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd),, Ourense, Spain
| | - María Salve
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense, Spain.,Instituto de Investigación Biomédica Galicia Sur, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd),, Ourense, Spain
| | - Luis Bujanda
- Donostia Hospital, Biodonostia Institute, University of the Basque Country UPV/EHU, CIBERehd, San Sebastian, Spain
| | - Joaquín Cubiella
- Department of Gastroenterology, Complexo Hospitalario Universitario de Ourense, Ourense, Spain. .,Instituto de Investigación Biomédica Galicia Sur, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBERehd),, Ourense, Spain.
| |
Collapse
|
17
|
Rodriguez-Alonso L, Rodriguez-Moranta F, Arajol C, Gilabert P, Serra K, Martin A, Ibáñez-Sanz G, Moreno V, Guardiola J. Proton pump inhibitors reduce the accuracy of faecal immunochemical test for detecting advanced colorectal neoplasia in symptomatic patients. PLoS One 2018; 13:e0203359. [PMID: 30169524 PMCID: PMC6118361 DOI: 10.1371/journal.pone.0203359] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Accepted: 08/20/2018] [Indexed: 02/06/2023] Open
Abstract
Background The faecal immunochemical test (FIT) is used in colorectal cancer (CRC) screening and for the detection of advanced colorectal neoplasia (AN) in symptomatic patients, but its accuracy could be improved. Our objective was to assess the impact of proton pump inhibitors (PPI) on the accuracy of the FIT in the detection of AN, namely advanced colorectal adenoma and CRC. Methods and findings We performed a prospective study of 1002 individuals referred for a diagnostic colonoscopy at Bellvitge University Hospital from September 2011 through to October 2012. An exhaustive interview was performed by a gastroenterologist, prescription drug dispensing database was reviewed and the patient was given a FIT prior to colonoscopy. The positivity threshold of FIT used was ≥ 20 μg Hb/g feces and the main outcome was AN. AN was detected in 13.2% (133) of patients. The accuracy of FIT for detecting AN in the PPI users and non-PPI users were: sensitivity 43.0% vs 65.6%, P = 0.009; specificity 86.9% vs 92.3%, P = 0.010; and, predictive positive value 34.4% vs 55.5%, P = 0.007, respectively. In multivariate analysis, adjusting for potential confounders, PPIs were associated with false positives in AN detection by FIT (OR 1.63 CI 95% 1.02–2.59, P < 0.037). The ROC curve for the FIT in the detection of AN in the PPI users and non-PPI users was 0.68 (CI 95% 0.61–0.76) and 0.85 (CI 95% 0.79–0.90). Conclusions PPI therapy reduces the accuracy of FIT for detecting AN in symptomatic patients.
Collapse
Affiliation(s)
- Lorena Rodriguez-Alonso
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
| | | | - Claudia Arajol
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
| | - Pau Gilabert
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
| | - Katja Serra
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
| | - Albert Martin
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
| | - Gemma Ibáñez-Sanz
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
- Catalan Institute of Oncology, Cancer Prevention and Control Programme, IDIBELL, Barcelona, Spain
| | - Victor Moreno
- Catalan Institute of Oncology, Cancer Prevention and Control Programme, IDIBELL, Barcelona, Spain
| | - Jordi Guardiola
- Department of Gastroenterology and Hepatology, University Hospital of Bellvitge-IDIBELL, Barcelona, Spain
- * E-mail:
| |
Collapse
|
18
|
The value of using the faecal immunochemical test in general practice on patients presenting with non-alarm symptoms of colorectal cancer. Br J Cancer 2018; 119:471-479. [PMID: 30065255 PMCID: PMC6133998 DOI: 10.1038/s41416-018-0178-7] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 06/18/2018] [Indexed: 12/15/2022] Open
Abstract
Background Around 50% of individuals with colorectal cancer (CRC) initially
present with non-alarm symptoms. Methods We investigated the value of using the faecal immunochemical test
(FIT) in the diagnostic process of CRC and other serious bowel disease in
individuals presenting with non-alarm symptoms in general practice. The study was
conducted in the Central Denmark Region from 1 September 2015 to 30 August 2016.
The FIT was used as a rule-in test on patients aged ≥30 years with non-alarm
symptoms of CRC. The cut-off value was set to 10 µg Hb/g faeces. Results A total of 3462 valid FITs were performed. Of these, 540 (15.6%)
were positive. Three months after FIT performance, 51 (PPV: 9.4% (95% CI:
7.0;11.9)) individuals with a positive FIT were diagnosed with CRC and 73 (PPV:
13.5% (95%CI: 10.6;16.4)) with other serious bowel disease. Of CRCs, 66.7% were
diagnosed in UICC stage I & II and 19.6% in stage IV. The false negative rate
for CRC was <0.1% for the initial 3 months after FIT performance. Conclusion The FIT may be used as a supplementary diagnostic test in the
diagnostic process of CRC and other serious bowel disease in individuals with
non-alarm symptoms of CRC in general practice.
Collapse
|
19
|
Mellen S, de Ferrars M, Chapman C, Bevan S, Turvill J, Turnock D. Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches. Ann Clin Biochem 2018. [DOI: 10.1177/0004563218766393] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Background Faecal immunochemical testing is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of preanalytical factors on faecal haemoglobin when measured by faecal immunochemical testing. The aim of this work was to evaluate the stability of faecal haemoglobin in faeces and to compare two methods of faecal haemoglobin sampling for faecal immunochemical testing. Methods Six patients provided faeces for faecal haemoglobin measurement which were transferred into specialized collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialized collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure faecal haemoglobin and results were compared categorically. Discrepant results were assessed against diagnosis. Results Faecal haemoglobin concentration declined rapidly within a day of storage at room temperature but results remained ≥10 μg Hb/g faeces in 5/6 patients after two days. A faecal haemoglobin result ≥10 μg Hb/g faeces was obtained in 4/6 patients after storage for seven days at 4°C. Results obtained when patients used specialized collection devices were significantly different from results obtained when faeces was transferred into the specialized collection device in the laboratory. Conclusion There is considerable heterogeneity in the sample stability of faecal haemoglobin; therefore, samples should be transferred rapidly into specialized collection devices to prevent false-negative results. Use of collection devices by patients can lead to false-positive results compared with their use in a laboratory.
Collapse
Affiliation(s)
- Samantha Mellen
- Department of Clinical Biochemistry, York Teaching Hospital NHS Foundation Trust, York, UK
| | - Maria de Ferrars
- Department of Clinical Biochemistry, York Teaching Hospital NHS Foundation Trust, York, UK
| | - Claire Chapman
- Department of Clinical Biochemistry, York Teaching Hospital NHS Foundation Trust, York, UK
| | - Sarah Bevan
- Department of Clinical Biochemistry, York Teaching Hospital NHS Foundation Trust, York, UK
| | - James Turvill
- Department of Gastroenterology, York Teaching Hospital NHS Foundation Trust, York, UK
| | - Daniel Turnock
- Department of Clinical Biochemistry, York Teaching Hospital NHS Foundation Trust, York, UK
| |
Collapse
|
20
|
Fraser CG. Faecal immunochemical tests (FIT) in the assessment of patients presenting with lower bowel symptoms: Concepts and challenges. Surgeon 2018; 16:302-308. [PMID: 29548552 DOI: 10.1016/j.surge.2018.01.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Accepted: 01/30/2018] [Indexed: 12/25/2022]
Abstract
Colonoscopy is a relatively scarce resource in many countries, including Scotland, and a simple investigation which would aid general practitioners in particular in decision-making as to which patients presenting with lower bowel symptoms warranted referral would be of much help. Faecal immunochemical tests for haemoglobin (FIT) have many advantageous characteristics and are now proven to be of considerable value in the timely assessment of patients with symptoms of lower bowel disease. Quantitative FIT provide numerical estimates of faecal haemoglobin concentration (f-Hb) and, at low f-Hb cut-off, FIT have high sensitivity for colorectal cancer (CRC) and could be used as a rule-in test to stimulate rapid referral, especially when symptoms are suggestive of serious bowel disease. Perhaps more importantly, a low f-Hb gives considerable reassurance that significant bowel disease (CRC + higher-risk adenoma + inflammatory bowel disease) is absent and further investigation may not be warranted: however, no test is perfect, so some cases will remain undetected using FIT alone and robust safety netting is required, possibly including watching and waiting, referral to clinics in secondary care, or a repeat FIT. Moreover, the FIT results should not be taken in isolation, but clinical impressions and the results of other investigations, probably including the full blood count, should be considered. Challenges still exist, however, and harmonisation of aspects of the available FIT analytical systems is required. Moreover, a number of seemingly valid clinical concerns remain and these require resolution through further research and reporting of studies done in real clinical practice.
Collapse
Affiliation(s)
- Callum G Fraser
- Centre for Research into Cancer Prevention and Screening, University of Dundee, Ninewells Hospital and Medical School, Dundee, DD1 9SY, Scotland, UK.
| |
Collapse
|
21
|
Westwood M, Corro Ramos I, Lang S, Luyendijk M, Zaim R, Stirk L, Al M, Armstrong N, Kleijnen J. Faecal immunochemical tests to triage patients with lower abdominal symptoms for suspected colorectal cancer referrals in primary care: a systematic review and cost-effectiveness analysis. Health Technol Assess 2018. [PMID: 28643629 DOI: 10.3310/hta21330] [Citation(s) in RCA: 51] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND Colorectal cancer (CRC) is the third most common cancer in the UK. Presenting symptoms that can be associated with CRC usually have another explanation. Faecal immunochemical tests (FITs) detect blood that is not visible to the naked eye and may help to select patients who are likely to benefit from further investigation. OBJECTIVES To assess the effectiveness of FITs [OC-Sensor (Eiken Chemical Co./MAST Diagnostics, Tokyo, Japan), HM-JACKarc (Kyowa Medex/Alpha Laboratories Ltd, Tokyo, Japan), FOB Gold (Sentinel/Sysmex, Sentinel Diagnostics, Milan, Italy), RIDASCREEN Hb or RIDASCREEN Hb/Hp complex (R-Biopharm, Darmstadt, Germany)] for primary care triage of people with low-risk symptoms. METHODS Twenty-four resources were searched to March 2016. Review methods followed published guidelines. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. The cost-effectiveness analysis considered long-term costs and quality-adjusted life-years (QALYs) that were associated with different faecal occult blood tests and direct colonoscopy referral. Modelling comprised a diagnostic decision model, a Markov model for long-term costs and QALYs that were associated with CRC treatment and progression, and a Markov model for QALYs that were associated with no CRC. RESULTS We included 10 studies. Using a single sample and 10 µg Hb/g faeces threshold, sensitivity estimates for OC-Sensor [92.1%, 95% confidence interval (CI) 86.9% to 95.3%] and HM-JACKarc (100%, 95% CI 71.5% to 100%) indicated that both may be useful to rule out CRC. Specificity estimates were 85.8% (95% CI 78.3% to 91.0%) and 76.6% (95% CI 72.6% to 80.3%). Triage using FITs could rule out CRC and avoid colonoscopy in approximately 75% of symptomatic patients. Data from our systematic review suggest that 22.5-93% of patients with a positive FIT and no CRC have other significant bowel pathologies. The results of the base-case analysis suggested minimal difference in QALYs between all of the strategies; no triage (referral straight to colonoscopy) is the most expensive. Faecal immunochemical testing was cost-effective (cheaper and more, or only slightly less, effective) compared with no triage. Faecal immunochemical testing was more effective and costly than guaiac faecal occult blood testing, but remained cost-effective at a threshold incremental cost-effectiveness ratio of £30,000. The results of scenario analyses did not differ substantively from the base-case. Results were better for faecal immunochemical testing when accuracy of the guaiac faecal occult blood test (gFOBT) was based on studies that were more representative of the correct population. LIMITATIONS Only one included study evaluated faecal immunochemical testing in primary care; however, all of the other studies evaluated faecal immunochemical testing at the point of referral. Further, validation data for the Faecal haemoglobin, Age and Sex Test (FAST) score, which includes faecal immunochemical testing, showed no significant difference in performance between primary and secondary care. There were insufficient data to adequately assess FOB Gold, RIDASCREEN Hb or RIDASCREEN Hb/Hp complex. No study compared FIT assays, or FIT assays versus gFOBT; all of the data included in this assessment refer to the clinical effectiveness of individual FIT methods and not their comparative effectiveness. CONCLUSIONS Faecal immunochemical testing is likely to be a clinically effective and cost-effective strategy for triaging people who are presenting, in primary care settings, with lower abdominal symptoms and who are at low risk for CRC. Further research is required to confirm the effectiveness of faecal immunochemical testing in primary care practice and to compare the performance of different FIT assays. STUDY REGISTRATION This study is registered as PROSPERO CRD42016037723. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
| | - Isaac Corro Ramos
- Institute for Medical Technology Assessment, Erasmus University Rotterdam, Rotterdam, the Netherlands
| | - Shona Lang
- Kleijnen Systematic Reviews Ltd, York, UK
| | - Marianne Luyendijk
- Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands
| | - Remziye Zaim
- Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands
| | - Lisa Stirk
- Kleijnen Systematic Reviews Ltd, York, UK
| | - Maiwenn Al
- Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, the Netherlands
| | | | - Jos Kleijnen
- School for Public Health and Primary Care (Care and Public Health Research Institute), Maastricht University, Maastricht, the Netherlands
| |
Collapse
|
22
|
Lord AR, Simms LA, Brown A, Hanigan K, Krishnaprasad K, Schouten B, Croft AR, Appleyard MN, Radford-Smith GL. Development and evaluation of a risk assessment tool to improve clinical triage accuracy for colonoscopic investigations. BMC Cancer 2018; 18:229. [PMID: 29486733 PMCID: PMC6389276 DOI: 10.1186/s12885-018-4140-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Accepted: 02/19/2018] [Indexed: 01/24/2023] Open
Abstract
Background Gastroenterology Departments at hospitals within Australia receive thousands of General Practitioner (GP)-referral letters for gastrointestinal investigations every month. Many of these requests are for colonoscopy. This study aims to evaluate the performance of the current symptoms-based triage system compared to a novel risk score using objective markers. Methods Patients with lower abdominal symptoms referred by their GPs and triaged by a Gastroenterology consultant to a colonoscopy consent clinic were recruited into the study. A risk assessment tool (RAT) was developed using objective data (clinical, demographic, pathology (stool test, FIT), standard blood tests and colonoscopy outcome). Colonoscopy and histology results were scored and then stratified as either significant bowel disease (SBD) or non-significant bowel disease (non-SBD). Results Of the 467 patients in our study, 45.1% were male, the mean age was 54.3 ± 13.8 years and mean BMI was 27.8 ± 6.2. Overall, 26% had SBD compared to 74% with non-SBD (42% of the cohort had a normal colonoscopy). Increasing severity of referral symptoms was related to a higher triage category, (rectal bleeding, P = 2.86*10-9; diarrhoea, P = 0.026; abdominal pain, P = 5.67*10-4). However, there was no significant difference in the prevalence of rectal bleeding (P = 0.991) or diarrhoea (P = 0.843) for SBD. Abdominal pain significantly reduced the risk of SBD (P = 0.0344, OR = 0.52, CI = 0.27-0.95). Conversely, the RAT had a very high specificity of 98% with PPV and NPV of SBD prediction, 74% and 77%, respectively. The RAT provided an odds ratio (OR) of 9.0, 95%CI 4.29-18.75, p = 2.32*10-11), higher than the FIT test (OR = 5.3, 95%CI 2.44-11.69, p = 4.88*10-6), blood score (OR = 2.8, 95%CI 1.72- 4.38, p = 1.47*10-5) or age (OR = 2.5, 95%CI 1.61-4.00, 5.12*10-5) independently. Notably, the ORs of these individual objective measures were higher than the current practice of symptoms-based triaging (OR = 1.4, 95%CI 0.88-2.11, p = 0.153). Conclusions It is critical that individuals with high risk of having SBD are triaged to the appropriate category with the shortest wait time. Here we provide evidence that a combination of blood markers, demographic markers and the FIT test have a higher diagnostic accuracy for SBD than FIT alone.
Collapse
Affiliation(s)
- Anton R Lord
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia.
| | - Lisa A Simms
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Allison Brown
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia.,Department of Gastroenterology and Hepatology, Royal Brisbane and Women's Hospital, Brisbane, Australia
| | - Katherine Hanigan
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Krupa Krishnaprasad
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Belinda Schouten
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Anthony R Croft
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia
| | - Mark N Appleyard
- Department of Gastroenterology and Hepatology, Royal Brisbane and Women's Hospital, Brisbane, Australia
| | - Graham L Radford-Smith
- Inflammatory Bowel Diseases, QIMR Berghofer Medical Research Institute, Brisbane, Australia.,Department of Gastroenterology and Hepatology, Royal Brisbane and Women's Hospital, Brisbane, Australia.,University of Queensland School of Medicine, Brisbane, Australia
| |
Collapse
|
23
|
Högberg C, Söderström L, Lilja M. Faecal immunochemical tests for the diagnosis of symptomatic colorectal cancer in primary care: the benefit of more than one sample. Scand J Prim Health Care 2017; 35:369-372. [PMID: 29183266 PMCID: PMC5730035 DOI: 10.1080/02813432.2017.1397255] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
OBJECTIVE Faecal immunochemical tests (FITs) are used to screen for colorectal cancer (CRC) and as diagnostic aids in symptomatic patients. However, the number of samples per FIT varies. It is unclear if there is any advantage to analyse multiple-sample FITs in symptomatic patients. DESIGN AND SETTING This is a post hoc analysis of a retrospective study that included all cases of CRC and adenomas with high-grade dysplasia (HGD) between 2005 and 2009 in the county of Jämtland, Sweden. SUBJECTS All patients with CRC and adenomas with HGD that initially presented with symptoms to primary care and delivered FITs. MAIN OUTCOME MEASURE The likelihood of a positive FIT in cases of CRC and adenomas with HGD; when analysing one, two or three samples. RESULTS Of 195 patients, 160 delivered three-sample FITs. Using the 139 cases in which at least one sample was positive, the likelihood of detecting a positive sample upon analysis of only one of the three samples was 0.91 (95% CI: 0.85-0.95), indicating that 13 positive cases may have been missed. CONCLUSION Use of a one-sample FIT instead of a three-sample FIT as a diagnostic aid may result in the missing of one tenth of symptomatic CRCs and adenomas with HGD.
Collapse
Affiliation(s)
- Cecilia Högberg
- Department of Public Health and Clinical Medicine, Unit of Research, Education, and Development – Östersund, Umeå University, Umeå, Sweden
- CONTACT Cecilia Högberg Unit of Research, Education, and Development, Östersund Hospital, Box 654, S-83127 Östersund, Sweden
| | - Lars Söderström
- Unit of Research, Education, and Development, Region Jämtland Härjedalen, Östersund, Sweden
| | - Mikael Lilja
- Department of Public Health and Clinical Medicine, Unit of Research, Education, and Development – Östersund, Umeå University, Umeå, Sweden
| |
Collapse
|
24
|
Westwood M, Lang S, Armstrong N, van Turenhout S, Cubiella J, Stirk L, Ramos IC, Luyendijk M, Zaim R, Kleijnen J, Fraser CG. Faecal immunochemical tests (FIT) can help to rule out colorectal cancer in patients presenting in primary care with lower abdominal symptoms: a systematic review conducted to inform new NICE DG30 diagnostic guidance. BMC Med 2017; 15:189. [PMID: 29061126 PMCID: PMC5654140 DOI: 10.1186/s12916-017-0944-z] [Citation(s) in RCA: 76] [Impact Index Per Article: 10.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Accepted: 09/14/2017] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND This study has attempted to assess the effectiveness of quantitative faecal immunochemical tests (FIT) for triage of people presenting with lower abdominal symptoms, where a referral to secondary care for investigation of suspected colorectal cancer (CRC) is being considered, particularly when the 2-week criteria are not met. METHODS We conducted a systematic review following published guidelines for systematic reviews of diagnostic tests. Twenty-one resources were searched up until March 2016. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. RESULTS Nine studies are included in this review. One additional study, included in our systematic review, was provided as 'academic in confidence' and cannot be described herein. When FIT was based on a single faecal sample and a cut-off of 10 μg Hb/g faeces, sensitivity estimates indicated that a negative result using either the OC-Sensor or HM-JACKarc may be adequate to rule out nearly all CRC; the summary estimate of sensitivity for the OC-Sensor was 92.1% (95% confidence interval, CI 86.9-95.3%), based on four studies (n = 4091 participants, 176 with CRC), and the only study of HM-JACKarc to assess the 10 μg Hb/g faeces cut-off (n = 507 participants, 11 with CRC) reported a sensitivity of 100% (95% CI 71.5-100%). The corresponding specificity estimates were 85.8% (95% CI 78.3-91.0%) and 76.6% (95% CI 72.6-80.3%), respectively. When the diagnostic criterion was changed to include lower grades of neoplasia, i.e. the target condition included higher risk adenoma (HRA) as well as CRC, the rule-out performance of both FIT assays was reduced. CONCLUSIONS There is evidence to suggest that triage using FIT at a cut-off around 10 μg Hb/g faeces has the potential to correctly rule out CRC and avoid colonoscopy in 75-80% of symptomatic patients. SYSTEMATIC REVIEW REGISTRATION PROSPERO 42016037723.
Collapse
Affiliation(s)
- Marie Westwood
- Kleijnen Systematic Reviews Ltd, Unit 6, Escrick Business Park, Riccall Road, Escrick, York, YO19 6FD, UK.
| | - Shona Lang
- Kleijnen Systematic Reviews Ltd, Unit 6, Escrick Business Park, Riccall Road, Escrick, York, YO19 6FD, UK
| | - Nigel Armstrong
- Kleijnen Systematic Reviews Ltd, Unit 6, Escrick Business Park, Riccall Road, Escrick, York, YO19 6FD, UK
| | | | - Joaquín Cubiella
- Department of Gastroenterology, Complexo Hospitalario, Universitario de Ourense, Ourense, Spain
| | - Lisa Stirk
- Kleijnen Systematic Reviews Ltd, Unit 6, Escrick Business Park, Riccall Road, Escrick, York, YO19 6FD, UK
| | - Isaac Corro Ramos
- Institute for Medical Technology Assessment, Erasmus University Rotterdam, Rotterdam, The Netherlands
| | - Marianne Luyendijk
- Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, The Netherlands
| | - Remziye Zaim
- Institute of Health Policy and Management, Erasmus University Rotterdam, Rotterdam, The Netherlands
| | - Jos Kleijnen
- School for Public Health and Primary Care (CAPHRI), Maastricht University, Maastricht, The Netherlands
| | - Callum G Fraser
- University of Dundee, Ninewells Hospital and Medical School, Dundee, DD1 9SY, UK
| |
Collapse
|
25
|
Quyn AJ, Steele RJ, Digby J, Strachan JA, Mowat C, McDonald PJ, Carey FA, Godber IM, Younes HB, Fraser CG. Application of NICE guideline NG12 to the initial assessment of patients with lower gastrointestinal symptoms: not FIT for purpose? Ann Clin Biochem 2017; 55:69-76. [PMID: 28661203 DOI: 10.1177/0004563217707981] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Background The National Institute for Health and Care Excellence (NICE) published NG12 in 2015. The referral criteria for suspected colorectal cancer (CRC) caused controversy, because tests for occult blood in faeces were recommended. Faecal immunochemical tests for haemoglobin (FIT), which estimate faecal haemoglobin concentrations (f-Hb), might more than fulfil the intentions. Our aim was to compare the utility of f-Hb as the initial investigation with the NICE NG12 symptom-based guidelines. Methods Data from three studies were included. Patients had sex, age, symptoms, f-Hb and colonoscopy and histology data recorded. Sensitivity, specificity, positive (PPV) and negative predictive value (NPV) of f-Hb and NG12 were calculated for all significant colorectal disease (SCD: CRC, higher risk adenoma and inflammatory bowel disease). Overall diagnostic accuracy was also estimated by the area under the receiver operating characteristic curve (AUC). Results A total of 1514 patients were included. At a cut-off of ≥10 µg Hb/g faeces, the sensitivity of f-Hb for CRC was 93.3% (95% confidence interval (CI): 80.7-98.3) with NPV of 99.7% (95%CI: 99.2-99.9). The sensitivity and NPV for SCD were 63.2% (95%CI: 56.6-69.4) and 96.0% (95%CI: 91.4-94.4), respectively. The NG12 sensitivity and NPV for SCD were 58.4% (95%CI: 51.8-64.8) and 87.6% (95%CI: 85.0-89.8), respectively. The AUC for CRC was 0.85 (95% CI: 0.87-0.90) for f-Hb versus 0.65 (95%CI: 0.58-0.73) for NG12 ( P < 0.005). For SCD, the AUC was 0.73 (95%CI: 0.69-0.77) for f-Hb versus 0.56 (95%CI: 0.52-0.60) for NG12 ( P < 0.0005). Conclusion f-Hb provides a good rule-out test for SCD and has significantly higher overall diagnostic accuracy than NG12.
Collapse
Affiliation(s)
- Aaron J Quyn
- 1 Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| | - Robert Jc Steele
- 1 Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| | - Jayne Digby
- 1 Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| | | | - Craig Mowat
- 3 Department of Gastroenterology, Ninewells Hospital and Medical School, Dundee, UK
| | - Paula J McDonald
- 2 Blood Sciences, Ninewells Hospital and Medical School, Dundee, UK
| | - Francis A Carey
- 4 Department of Pathology, Ninewells Hospital and Medical School, Dundee, UK
| | - Ian M Godber
- 5 Department of Biochemistry, Monklands Hospital, Lanarkshire, UK
| | - Hakim B Younes
- 6 Department of Surgery, Wishaw General Hospital, Lanarkshire, UK
| | - Callum G Fraser
- 1 Centre for Research into Cancer Prevention and Screening, University of Dundee, Dundee, UK
| |
Collapse
|
26
|
Elias SG, Kok L, de Wit NJ, Witteman BJM, Goedhard JG, Romberg-Camps MJL, Muris JWM, Moons KGM. Is there an added value of faecal calprotectin and haemoglobin in the diagnostic work-up for primary care patients suspected of significant colorectal disease? A cross-sectional diagnostic study. BMC Med 2016; 14:141. [PMID: 27666114 PMCID: PMC5036273 DOI: 10.1186/s12916-016-0684-5] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2016] [Accepted: 08/31/2016] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND The majority of primary care patients referred for bowel endoscopy do not have significant colorectal disease (SCD), and are - in hindsight - unnecessarily exposed to a small but realistic risk of severe endoscopy-associated complications. We developed a diagnostic strategy to better exclude SCD in these patients and evaluated the value of adding a faecal calprotectin point-of-care (POC) and/or a POC faecal immunochemical test for haemoglobin (FIT) to routine clinical information. METHODS We used data from a prospective diagnostic study in SCD-suspected patients from 266 Dutch primary care practices referred for endoscopy to develop a diagnostic model for SCD with routine clinical information, which we extended with faecal calprotectin POC (quantitatively in μg/g faeces) and/or POC FIT results (qualitatively with a 6 μg/g faeces detection limit). We defined SCD as colorectal cancer (CRC), inflammatory bowel disease, diverticulitis, or advanced adenoma (>1 cm). RESULTS Of 810 patients, 141 (17.4 %) had SCD. A diagnostic model with routine clinical data discriminated between patients with and without SCD with an area under the receiver operating characteristic curve (AUC) of 0.741 (95 % CI, 0.694-0.789). This AUC increased to 0.763 (95 % CI, 0.718-0.809; P = 0.078) when adding the calprotectin POC test, to 0.831 (95 % CI, 0.791-0.872; P < 0.001) when adding the POC FIT, and to 0.837 (95 % CI, 0.798-0.876; P < 0.001) upon combined extension. At a ≥ 5.0 % SCD probability threshold for endoscopy referral, 30.4 % of the patients tested negative based on this combined POC-tests extended model (95 % CI, 25.7-35.3 %), with 96.4 % negative predictive value (95 % CI, 93.1-98.2 %) and 93.7 % sensitivity (95 % CI, 88.2-96.8 %). Excluding the calprotectin POC test from this model still yielded 30.1 % test negatives (95 % CI, 24.7-35.6 %) and 96.0 % negative predictive value (95 % CI, 92.6-97.9 %), with 93.0 % sensitivity (95 % CI, 87.4-96.4 %). CONCLUSIONS FIT - and to a much lesser extent calprotectin - POC testing showed incremental value for SCD diagnosis beyond standard clinical information. A diagnostic strategy with routine clinical data and a POC FIT test may safely rule out SCD and prevent unnecessary endoscopy referral in approximately one third of SCD-suspected primary care patients. Please see related article: http://bmcmedicine.biomedcentral.com/articles/10.1186/s12916-016-0694-3 .
Collapse
Affiliation(s)
- Sjoerd G Elias
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Stratenum 6.131, P.O. Box 85500, 3508, GA, Utrecht, The Netherlands.
| | - Liselotte Kok
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Stratenum 6.131, P.O. Box 85500, 3508, GA, Utrecht, The Netherlands
| | - Niek J de Wit
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Stratenum 6.131, P.O. Box 85500, 3508, GA, Utrecht, The Netherlands
| | - Ben J M Witteman
- Department of Gastroenterology, Gelderse Vallei Hospital, Ede, The Netherlands
| | - Jelle G Goedhard
- Department of Gastroenterology, Atrium Medical Center, Heerlen, The Netherlands
| | | | - Jean W M Muris
- The Department of Family Medicine, Care and Public Health Research Institute (Caphri), Maastricht University, Maastricht, The Netherlands
| | - Karel G M Moons
- Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Stratenum 6.131, P.O. Box 85500, 3508, GA, Utrecht, The Netherlands
| |
Collapse
|