1
|
Wuest B, Gavrilović I, Cowan D, Torre XDL, Botrè F, Parr MK. Analysis of doping control samples using supercritical fluid chromatography-tandem mass spectrometry: Ready for routine use. J Sep Sci 2023; 46:e2200880. [PMID: 36739523 DOI: 10.1002/jssc.202200880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 02/01/2023] [Accepted: 02/02/2023] [Indexed: 02/06/2023]
Abstract
Supercritical fluid chromatography is proving to be a good separation and sample preparation tool for various analytical applications and, as such, has gained the attention of the anti-doping community. Here, the applicability of supercritical fluid chromatography hyphenated to tandem mass spectrometry for routine doping control analysis was tested. A multi-analyte method was developed to cover 197 drugs and metabolites that are prohibited in sport. More than 1000 samples were analyzed by applying a "dilute and inject" approach after hydrolysis of glucuronide metabolites. Additionally, a comparison with routinely used liquid chromatography-mass spectrometry was performed with 250 of the 1000 samples and a number of past positive anti-doping samples. It revealed some features where supercritical fluid chromatography-tandem mass spectrometry was found to be complementary or advantageous to liquid chromatography-mass spectrometry for anti-doping purposes, such as better retention of analytes that are poorly retained in reversed-phase liquid chromatography. Our results suggest that supercritical fluid chromatography-tandem mass spectrometry is sensitive (limit of detection <50% relevant minimum required performance level required by the World Anti-Doping Agency for anti-doping analysis), reproducible, robust, precise (analytes of interest area coefficient of variation <5%; retention time difference coefficient of variation <1%) and complementary to existing techniques currently used for routine analysis in the World Anti-Doping Agency accredited laboratories.
Collapse
Affiliation(s)
| | - Ivana Gavrilović
- Department of Analytical, Environmental and Forensic Sciences, Drug Control Centre, King's Forensics, King's College London, London, UK
| | - David Cowan
- Department of Analytical, Environmental and Forensic Sciences, King's College London, London, UK
| | | | - Francesco Botrè
- Laboratorio Antidoping FMSI, Rome, Italy.,Research and Expertise on Antidoping sciences, Institute de sciences du sport, Université de Lausanne, Lausanne, Switzerland
| | | |
Collapse
|
2
|
Cormican JA, Soh WT, Mishto M, Liepe J. iBench: A ground truth approach for advanced validation of mass spectrometry identification method. Proteomics 2023; 23:e2200271. [PMID: 36189881 PMCID: PMC10078205 DOI: 10.1002/pmic.202200271] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 09/23/2022] [Accepted: 09/28/2022] [Indexed: 01/19/2023]
Abstract
The discovery of many noncanonical peptides detectable with sensitive mass spectrometry inside, outside, and on cells shepherded the development of novel methods for their identification, often not supported by a systematic benchmarking with other methods. We here propose iBench, a bioinformatic tool that can construct ground truth proteomics datasets and cognate databases, thereby generating a training court wherein methods, search engines, and proteomics strategies can be tested, and their performances estimated by the same tool. iBench can be coupled to the main database search engines, allows the selection of customized features of mass spectrometry spectra and peptides, provides standard benchmarking outputs, and is open source. The proof-of-concept application to tryptic proteome digestions, immunopeptidomes, and synthetic peptide libraries dissected the impact that noncanonical peptides could have on the identification of canonical peptides by Mascot search with rescoring via Percolator (Mascot+Percolator).
Collapse
Affiliation(s)
- John A. Cormican
- Max‐Planck‐Institute for Multidisciplinary Sciences (MPI‐NAT)GöttingenGermany
| | - Wai Tuck Soh
- Max‐Planck‐Institute for Multidisciplinary Sciences (MPI‐NAT)GöttingenGermany
| | - Michele Mishto
- Centre for Inflammation Biology and Cancer Immunology (CIBCI) & Peter Gorer Department of ImmunobiologyKing's College LondonLondonUK
- The Francis Crick InstituteLondonUK
| | - Juliane Liepe
- Max‐Planck‐Institute for Multidisciplinary Sciences (MPI‐NAT)GöttingenGermany
| |
Collapse
|
3
|
Kovač M, Nevistić A, Kovač T, Babić J, Šarić A, Miličević B, Panjičko M, Šarkanj B. Development and Validation of an UHPLC-MS/MS Method for the Simultaneous Determination of 11 EU-Regulated Mycotoxins in Selected Cereals. J Fungi (Basel) 2022; 8. [PMID: 35887422 DOI: 10.3390/jof8070665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 06/17/2022] [Accepted: 06/21/2022] [Indexed: 02/04/2023] Open
Abstract
The availability of reliable sensitive multi-analyte methods for unambiguous determination of mycotoxins is crucial for ensuring food and feed safety, considering their adverse health effects and (co-)occurrence in various foods. Accordingly, a multi-mycotoxin confirmatory method for simultaneous determination of 11 mycotoxins regulated in cereals within the European Union (EU) using ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) was developed and in-house validated to fit the EU legislation requirements for analytical methods. A simple sample preparation was based on a solid−liquid extraction using a solvent mixture acetonitrile/water/formic acid (79/20/1, v/v/v) and a dilution of raw extract using water/acetonitrile/formic acid (79/20/1, v/v/v) before instrumental analysis. Average recoveries in all three validated cereal crop types (maize, wheat, and barley), spiked at multiple levels, were found acceptable for all analytes when matrix-matched calibration was used, ranging from 63.2% to 111.2% and also showing very good repeatability, with relative standard deviations below 20%. Matrix effect (SSE) evaluation revealed maize as the most complex of the three analyzed cereal matrices, with strong SSE (<50% and >150%) recorded for all 11 analyzed mycotoxins. An additional method verification was performed through successful participation in proficiency testing schemes, with the achieved z-scores generally in the acceptable range of −2 ≤ z ≤ 2. The obtained validation results demonstrated the suitability of the developed confirmatory multi-mycotoxin UHPLC-MS/MS method based on a dilute-and-shoot principle for the simultaneous determination of low concentrations of 11 EU-regulated mycotoxins in cereals, including aflatoxins B1, B2, G1 and G2, deoxynivalenol, fumonisins B1 and B2, zearalenone, T-2 and HT-2 toxins, and ochratoxin A.
Collapse
|
4
|
Coker C, Uysal S. Validation of an In-House-Developed GC-MS Method for 5α-Cholestanol According to ISO 15189:2012 Requirements. Lab Med 2021; 53:278-284. [PMID: 34894144 DOI: 10.1093/labmed/lmab095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVE The aim of this study was to validate a gas chromatography-mass spectrometry (GC-MS) method for the measurement of 5α-cholestanol in the clinical laboratory in agreement with ISO 15189:2012. MATERIALS AND METHODS The GC-MS performance was evaluated and proficiency testing data were used to estimate the measurement uncertainty of the method considering the recommendations of international guidelines. RESULTS The calibration curves were linear from 6 to 50 μmol/L, with r2 >.99. The limit of detection and limit of quantitation were determined to be 0.36 and 2.58 μmol/L, respectively. The bias ranged from -18.9% to 15.2% for 6.5, 18.3, and 66 μmol/L. The intra- and interassay reproducibility was <20% at the various concentrations studied. The expanded uncertainty was determined to be 50.9%. CONCLUSION The GC-MS method for the measurement of 5α-cholestanol has proved to have acceptable analytical performance for use in the clinical laboratory.
Collapse
Affiliation(s)
- Canan Coker
- Dokuz Eylül University Faculty of Medicine, Department of Biochemistry, Izmir, Turkey
| | - Sezer Uysal
- Dokuz Eylül University Faculty of Medicine, Department of Biochemistry, Izmir, Turkey
| |
Collapse
|
5
|
Feldhammer M, Brown M, Colby J, Bryksin J, Milstid B, Nichols JH. A Survey of Sigma Metrics across Three Academic Medical Centers. J Appl Lab Med 2021; 6:1264-1275. [PMID: 34060592 DOI: 10.1093/jalm/jfab028] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Accepted: 03/22/2021] [Indexed: 11/14/2022]
Abstract
BACKGROUND Sigma metric calculations provide laboratories an objective means to assess analytical method performance. Methods with higher sigma values are desirable because they are more reliable and may use less frequent quality control in order to maintain optimal performance. Sigma metrics can also serve as a tool when comparing method performance across assay and manufacturer platforms. METHODS Sigma values were calculated for 28 common chemistry and 24 immunoassay assays across 3 academic medical centers. Method imprecision and percent bias relative to peer group means was tabulated from Bio-Rad quality control (QC) data. Sigma values were calculated for each method using allowable total error (TEa) from either the CLIA evaluation limits or desirable biological variation. Average sigma values were generated for each site and graded as optimal: >6 sigma; good: 5-6 sigma; marginal: 3-5 sigma; or poor: <3 sigma. Analysis of NIST SRM1950 standards for a subset of analytes allowed an estimation of absolute bias. RESULTS Clinical chemistry assays displayed similar method performance across all 3 study sites. Immunoassays showed significant differences between manufacturers, and a majority of assays failed to meet an optimal level of performance. Different TEa values produced different sigma metrics with more stringent TEa limits based on biological variation, resulting in poorer performance estimates than the wider CLIA limits. Analysis of NIST standards revealed similar performance. CONCLUSIONS Sigma metrics are comparable for chemistry but not immunoassay platforms. The selection of total allowable error goals led to differences in sigma metrics.
Collapse
Affiliation(s)
- Matthew Feldhammer
- Department of Pathology and Laboratory Medicine, University of Florida College of Medicine, Jacksonville, FL, USA
| | - Megan Brown
- Department of Pathology and Laboratory Medicine, University of Florida College of Medicine, Jacksonville, FL, USA
| | - Jennifer Colby
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Janetta Bryksin
- Department of Pathology and Laboratory Medicine, Emory University School of Medicine, Atlanta, GA, USA
| | | | - James H Nichols
- Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN, USA
| |
Collapse
|
6
|
James T, Nicholson BD, Marr R, Paddon M, East JE, Justice S, Oke JL, Shine B. Faecal immunochemical testing (FIT): sources of result variation based on three years of routine testing of symptomatic patients in English primary care. Br J Biomed Sci 2021; 78:211-217. [PMID: 33627037 DOI: 10.1080/09674845.2021.1896204] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Introduction: We aimed to determine the analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect faecal haemoglobin (Hb) in symptomatic people attending primary care in the context of the English NICE DG30 guidance.Materials and Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive performance characteristics.Results: Detection capabilities for the FIT method were 0.5 µg/g (limit of blank), 1.3 µg/g (limit of detection) and 3.0 µg/g (limit of quantitation). Of 33 non-homogenized specimens, 31 (93.9%) analysed in triplicate were consistently categorized relative to 10 µg/g, compared to all 33 (100%) homogenized specimens. Imprecision was higher (median 27.8%, (range 20.5% to 48.6%)) in non-homogenized specimens than in homogenized specimens (10.2%, (7.0 to 13.5%)). Considerable variation was observed in sequential clinical specimens from individual patients but no positive or negative trend in specimen degradation was observed over time (p = 0.26).Discussion: The FIT immunoassay evaluated is capable of detecting faecal Hb at concentrations well below the DG30 threshold of 10 µg/g and is suitable for application in this context. The greatest practical challenge to FIT performance is reproducible sampling, the pre-analytical step associated with most variability. Further research should focus on reducing sampling variability, particularly as post-COVID-19 guidance recommends greater FIT utilization.
Collapse
Affiliation(s)
- T James
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - B D Nicholson
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - R Marr
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - M Paddon
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - J E East
- Translational Gastroenterology Unit, and Oxford NIHR Biomedical Research Centre, John Radcliffe Hospital, University of Oxford, Oxford, UK
| | - S Justice
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| | - J L Oke
- Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
| | - B Shine
- Department of Clinical Biochemistry, John Radcliffe Hospital, Oxford University Hospitals Trust, Oxford, UK
| |
Collapse
|
7
|
Senyuva HZ, Jones IB, Sykes M, Baumgartner S. A critical review of the specifications and performance of antibody and DNA-based methods for detection and quantification of allergens in foods. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2019; 36:507-547. [PMID: 30856064 DOI: 10.1080/19440049.2019.1579927] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Despite the availability of a large number of antibody and DNA based methods for detection and quantification of allergens in food there remain significant difficulties in selecting the optimum technique to employ. Published methods from research groups mostly contain sufficient detail concerning target antigen, calibration procedures and method performance to allow replication by others. However, routine allergen testing by the food industry relies upon commercialised test kits and frequently the suppliers provide disappointingly little specification detail on the grounds that this is proprietary information. In this review we have made a critical assessment of the published literature describing the performance of both commercial and non-commercial test kits for food allergens over the period 2008-2018. Mass spectrometric methods, which have the potential to become reference methods for allergens, are not covered in this review. Available information on the specifications of commercial ELISA and LFD test kits are tabulated for milk, egg and peanut allergens, where possible linking to publications concerning collaborative studies and proficiency testing. For a number of commercial PCR test kits, specifications provided by manufacturers for detection of a small selection of allergen are tabulated. In conclusion we support the views of others of the critical need for allergen reference materials as the way forward to improve the comparability of different testing strategies in foods.
Collapse
Affiliation(s)
| | - Ivona Baricevic Jones
- b Institute of Inflammation and Repair , Manchester Institute of Biotechnology , Manchester , UK
| | - Mark Sykes
- c Fera Science Ltd , National Agri-Food Innovation Campus Sand Hutton , York , UK
| | - Sabine Baumgartner
- d Dept. IFA-Tulln, Center for Analytical Chemistry , BOKU Vienna , Tulln , Austria
| |
Collapse
|
8
|
Abstract
Evaluation of method performance involves the consideration of numerous factors that can contribute to error. A variety of measures of performance can be borrowed from the signal detection literature and others are drawn from statistical science. This article demonstrates the principles of performance evaluation by applying multiple measures to osteometric sorting models for paired elements run against data from known individuals. Results indicate that false positive rates are close, on average, to expected values. As assemblage size grows, the false positive rate becomes unimportant and the false negative rate becomes significant. Size disparity among the commingled individuals plays a significant role in method performance, showing that case-specific circumstances (e.g. assemblage size and size disparity) will determine method power.
Collapse
Affiliation(s)
- John E Byrd
- Laboratory, Defense POW/MIA Accounting Agency, Joint Base Pearl Harbor-Hickam, HI, USA
| | - Carrie B LeGarde
- Laboratory, Defense POW/MIA Accounting Agency, Joint Base Pearl Harbor-Hickam, HI, USA
| |
Collapse
|