Schröder L, Mallmann MR, Domroese CM, Wefers N, Dolscheid-Pommerich R, Stoffel-Wagner B, Trulson I, Vahldiek K, Klawonn F, Holdenrieder S. Method Comparison and Clinical Performance of Breast Cancer Tumor Markers on Novel Multiplex Immunoassay and Automatized LOCI Technology Platforms. Diagnostics (Basel) 2023; 13:3101. [PMID: 37835844 PMCID: PMC10572608 DOI: 10.3390/diagnostics13193101] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/24/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023] Open
Abstract
Tumor marker determinations are valuable tools for the guidance of breast cancer patients during the course of disease. They are assessed on diverse analytical platforms that may be associated with differences according to the methods applied and the clinical performance. To investigate the method dependency and clinical significance of breast cancer protein tumor markers, CEA, CA 15-3, CA 125, CA 19-9 and AFP were measured in a total of 154 biobanked samples from 77 patients with breast cancer, 10 with DCIS, 31 with benign breast diseases and 36 healthy controls using a Millipore multiplex biomarker panel (MP) and an automized version of the routinely used Vista LOCI technology. The markers were compared between methods and investigated for diagnostic performance. CEA, CA 15-3 and AFP showed good correlations between both platforms with correlation coefficients of R = 0.85, 0.85 and 0.92, respectively, in all samples, but similarly also in the various subgroups. CA 125 and CA 19-9 showed only moderate correlations (R = 0.71 and 0.56, respectively). Absolute values were significantly higher for CEA, CA 15-3, CA 125 and AFP in the Vista LOCI as compared with the MP method and vice versa for CA 19-9. The diagnostic performance for discrimination of breast cancer from healthy controls was similar for both methods with AUCs in ROC curves for CEA (MP 0.81, 95% CI 0.72-0.91; LOCI 0.81; 95% CI 0.72-0.91) and CA-15-3 (MP 0.75, 95% CI 0.65-0.86; LOCI 0.67, 95% CI 0.54-0.79). Similar results were obtained for the comparison of breast cancer with benign breast diseases regarding CEA (AUC MP 0.62, 95% CI 0.51-0.73; LOCI 0.64, 95% CI 0.53-0.74) and CA-15-3 (MP 0.70, 95% CI 0.6-0.81; LOCI 0.66, 95% CI 0.54-0.77). Both platforms show moderate to good method comparability for tumor markers with similar clinical performance. However, absolute levels in individual patients should be interpreted with care.
Collapse
Affiliation(s)
- Lars Schröder
- Department of Gynecology, Ketteler-Hospital Offenbach, 63071 Offenbach, Germany
- Department of Gynecology, University Hospital Bonn, 53127 Bonn, Germany
- Department of Obstetrics and Gynecology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
| | - Michael R Mallmann
- Department of Gynecology, University Hospital Bonn, 53127 Bonn, Germany
- Department of Obstetrics and Gynecology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
| | - Christian M Domroese
- Department of Gynecology, University Hospital Bonn, 53127 Bonn, Germany
- Department of Obstetrics and Gynecology, Faculty of Medicine and University Hospital Cologne, University of Cologne, 50937 Cologne, Germany
| | - Natalie Wefers
- Institute of Clinical Chemistry and Clinical Pharmacology, University Hospital Bonn, 53127 Bonn, Germany
| | - Ramona Dolscheid-Pommerich
- Institute of Clinical Chemistry and Clinical Pharmacology, University Hospital Bonn, 53127 Bonn, Germany
| | - Birgit Stoffel-Wagner
- Institute of Clinical Chemistry and Clinical Pharmacology, University Hospital Bonn, 53127 Bonn, Germany
| | - Inga Trulson
- Munich Biomarker Research Center, Institute of Laboratory Medicine, German Heart Center, Technical University Munich, 80636 Munich, Germany
| | - Kai Vahldiek
- Department of Computer Science, Ostfalia University, 38302 Wolfenbüttel, Germany
| | - Frank Klawonn
- Munich Biomarker Research Center, Institute of Laboratory Medicine, German Heart Center, Technical University Munich, 80636 Munich, Germany
- Department of Computer Science, Ostfalia University, 38302 Wolfenbüttel, Germany
- Helmholtz Centre for Infection Research, Biostatistics, 38124 Braunschweig, Germany
| | - Stefan Holdenrieder
- Institute of Clinical Chemistry and Clinical Pharmacology, University Hospital Bonn, 53127 Bonn, Germany
- Munich Biomarker Research Center, Institute of Laboratory Medicine, German Heart Center, Technical University Munich, 80636 Munich, Germany
- Center for the Evaluation of Biomarkers, 81679 Munich, Germany
| |
Collapse
|
2
|
Fatica EM, Larson BJ, Algeciras-Schimnich A, Bornhorst JA. Performance characteristics of the BRAHMS KRYPTOR automated squamous cell carcinoma antigen assay. J Immunol Methods 2022; 504:113257. [PMID: 35304118 DOI: 10.1016/j.jim.2022.113257] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 03/10/2022] [Accepted: 03/11/2022] [Indexed: 12/25/2022]
Abstract
BACKGROUND Squamous cell carcinoma antigen (SCCA) is a glycoprotein biomarker for squamous cell carcinoma (SCC). SCCA elevations have also been noted in other conditions. The purpose of this study was to evaluate the analytical and clinical performance of an automated SCCA homogenous immunofluorescent assay (BRAHMS KRYPTOR). METHODS Reference intervals were determined using 119 samples from healthy donors. To assess clinical performance, samples were collected from patients with cervical (n = 12), head and neck (n = 23), lung (n = 14), or cutaneous (n = 11) SCC in addition to hepatocellular carcinoma, psoriasis, or atopic dermatitis. RESULTS Upper 95th percentile sex-specific reference intervals were 2.00 μg/L for males and 1.67 μg/L for females. Intra- and inter-assay CVs were less than 5%. Comparison of the BRAHMS KRYPTOR to an ELISA SCCA immunoassay exhibited a correlation coefficient of 0.8809. The mean sensitivity for all SCC positive patients was 23.3%. With the exception of psoriasis (58.6%) specificity exceeded 95% for the non-SCC populations. CONCLUSION The BRAHMS KRYPTOR SCCA assay showed good analytical performance and acceptable overall clinical specificity. Consistent with previous studies, the sensitivity of SCCA for SCC was low. In the absence of other robust circulating markers, SCCA remains an imperfect yet useful tool in the evaluation of SCC.
Collapse
Affiliation(s)
- Erica M Fatica
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA; Department of Pathology and Laboratory Medicine, University of Cincinnati, Cincinnati, OH, USA
| | - Bethany J Larson
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | | | - Joshua A Bornhorst
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
3
|
Lee S, Kim J, Uh Y, Kim HS, Lee JH. Comparison Between a Manual Squamous Cell Carcinoma Antigen Assay and an Automated Assay in a Clinical Setting. Lab Med 2018; 49:254-258. [PMID: 29566170 DOI: 10.1093/labmed/lmy003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objective To compare a manual squamous cell carcinoma antigen (SCCA) assay and an automated SCCA assay in a clinical setting. Methods We included, in this study, a total of 158 specimens that had been tested using the manual SCCA assay. The CanAg SCC EIA assay and the Elecsys SCC were compared for their clinical settings. Results Within-run and between-day coefficients of variation (CVs, %) were lower than 3%. Comparison of the manual and automated SCCA assays yielded good correlation. The correlation coefficient (R2) between the CanAg SCC EIA and Elecsys SCC assay results was 0.989 (P <.001) and the overall concordance rate was 94.3%. Conclusions We report that the Elecsys SCC automated SCCA assay yielded performance comparable to that of the manual SCCA assay: the automated assay reduced the number of manual steps and test turnaround time.
Collapse
Affiliation(s)
- Saejin Lee
- Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Juwon Kim
- Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Young Uh
- Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| | - Hyon-Suk Kim
- Department of Laboratory Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jong-Han Lee
- Department of Laboratory Medicine, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea
| |
Collapse
|