1
|
Van Der Schueren C, Decruyenaere P, Avila Cobos F, Bult J, Deleu J, Dipalo LL, Helsmoortel HH, Hulstaert E, Morlion A, Ramos Varas E, Schoofs K, Trypsteen W, Vanden Eynde E, Van Droogenbroeck H, Verniers K, Vandesompele J, Decock A. Subpar reporting of pre-analytical variables in RNA-focused blood plasma studies. Mol Oncol 2024. [PMID: 38564603 DOI: 10.1002/1878-0261.13647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 02/13/2024] [Accepted: 03/22/2024] [Indexed: 04/04/2024] Open
Abstract
Extracellular RNA (cell-free RNA; exRNA) from blood-derived liquid biopsies is an appealing, minimally invasive source of disease biomarkers. As pre-analytical variables strongly influence exRNA measurements, their reporting is essential for meaningful interpretation and replication of results. The aim of this review was to chart to what extent pre-analytical variables are documented, to pinpoint shortcomings and to improve future reporting. In total, 200 blood plasma exRNA studies published in 2018 or 2023 were reviewed for annotation of 22 variables associated with blood collection, plasma preparation, and RNA purification. Our results show that pre-analytical variables are poorly documented, with only three out of 22 variables described in over half of the publications. The percentage of variables reported ranged from 4.6% to 54.6% (mean 24.84%) in 2023 and from 4.6% to 57.1% (mean 28.60%) in 2018. Recommendations and guidelines (i.e., BRISQ, ASCO-CAP, BloodPAC, PPMPT, and CEN standards) have currently not resulted in improved reporting. In conclusion, our results highlight the lack of reporting pre-analytical variables in exRNA studies and advocate for a consistent use of available standards, endorsed by funders and journals.
Collapse
Affiliation(s)
| | - Philippe Decruyenaere
- Department of Biomolecular Medicine, Ghent University, Belgium
- Department of Hematology, Ghent University Hospital, Belgium
| | - Francisco Avila Cobos
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Johanna Bult
- Department of Biomolecular Medicine, Ghent University, Belgium
- Department of Hematology, University Medical Center Groningen, The Netherlands
| | - Jill Deleu
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Laudonia Lidia Dipalo
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Hetty Hilde Helsmoortel
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Eva Hulstaert
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
- Department of Dermatology, AZ Sint-Blasius, Belgium
| | - Annelien Morlion
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Elena Ramos Varas
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Kathleen Schoofs
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
- Translational Oncogenomics and Bioinformatics Lab, Cancer Research Institute Ghent (CRIG), Belgium
- Center for Medical Biotechnology, VIB-UGent, Belgium
| | - Wim Trypsteen
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Eveline Vanden Eynde
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Hanne Van Droogenbroeck
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Kimberly Verniers
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| | - Jo Vandesompele
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
- CellCarta, Belgium
| | - Anneleen Decock
- Department of Biomolecular Medicine, Ghent University, Belgium
- OncoRNALab, Cancer Research Institute Ghent (CRIG), Belgium
| |
Collapse
|
2
|
Gros N, Klobučar T, Gaber K. Accuracy of Citrate Anticoagulant Amount, Volume, and Concentration in Evacuated Blood Collection Tubes Evaluated with UV Molecular Absorption Spectrometry on a Purified Water Model. Molecules 2023; 28:molecules28020486. [PMID: 36677544 PMCID: PMC9860671 DOI: 10.3390/molecules28020486] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 01/06/2023] Open
Abstract
Citrate anticoagulant concentration affects the results of coagulation tests. Until now, the end user had no direct insight into the quality of evacuated blood collection tubes. By introducing an easy-to-perform UV spectrometric method for citrate determination on a purified water model, we enabled the evaluation of (1) the accuracy of the anticoagulant amount added into the tubes by a producer, (2) the accuracy of the volume of anticoagulant solution in the tube at the instant of examination, (3) the anticoagulant concentrations at a draw volume. We examined the Vacuette®, Greiner BIO-ONE, Vacutube, LT Burnik d.o.o., and BD Vacutainer® tubes. The anticoagulant amount added into the tubes during production had a relative bias between 3.2 and 23.0%. The anticoagulant volume deficiency at the instant of examination expressed as a relative bias ranged between -11.6 and -91.1%. The anticoagulant concentration relative bias after the addition of purified water in a volume that equalled a nominal draw volume extended from 9.3 to 25.7%. Draw-volume was mostly compliant during shelf life. Only Vacutube lost water over time. Contamination with potassium, magnesium, or both was observed in all the tubes but did not exceed a 0.21 mmol/L level. This study enables medical laboratories to gain insight into the characteristics of the citrate blood collection tubes as one of the preanalytical variables. In situations that require anticoagulant adjustment for accurate results, this can help make the right decisions. The methodology gives producers additional means of controlling the quality of their production process.
Collapse
|
3
|
de Laat-Kremers RMW, Ninivaggi M, Devreese KMJ, de Laat B. Towards standardization of thrombin generation assays: Inventory of thrombin generation methods based on results of an International Society of Thrombosis and Haemostasis Scientific Standardization Committee survey. J Thromb Haemost 2020; 18:1893-1899. [PMID: 32319140 DOI: 10.1111/jth.14863] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 04/03/2020] [Accepted: 04/16/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND Thrombin generation (TG) is a better determinant of the overall function of the hemostatic system than the routinely used clotting time-based assays. Nowadays, TG is widely used in hemostasis research teams, for both clinical and basic research. However, there is significant variability between laboratories regarding preanalytics, reagents, TG protocol, analysis interpretation, and normalization. OBJECTIVES To document the extent of variation in the methodology of TG, we aim to collect all the methods that are being used to measure TG in a survey. METHODS We organized a questionnaire through the Standardization committee for Lupus Anticoagulant/Antiphospholipid Antibodies of the International Society of Thrombosis and Haemostasis Scientific Standardization committee. The questionnaire consisted of 51 questions regarding the different aspects of TG: type of users, methods, sample type, analysis, and interpretation of results, normalization, and quality control. RESULTS Of the 240 surveys that were started, 108 were completed (45%). However, not all questions were in scope for all laboratories. One-half of the laboratories were research laboratories and half diagnostic laboratories. The most used TG assay was the calibrated automated thrombinography-based assay (56%). There was a divergence regarding several aspects of the TG assay: type of needle for blood collection, blood tubes, centrifugation, sample storage and thawing, reagents, sample dilution, calibration, reference ranges, data normalization, and so on. CONCLUSIONS There is an important variation in the methods used for measuring TG. A standardized protocol and data normalization should lead to a better reproducibility and for comparing data from different laboratories.
Collapse
Affiliation(s)
| | | | - Katrien M J Devreese
- Department of Laboratory Medicine, Coagulation Laboratory, Ghent University Hospital, Ghent, Belgium
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium
| | - Bas de Laat
- Synapse Research Institute, Maastricht, The Netherlands
| |
Collapse
|
4
|
Greco V, Piras C, Pieroni L, Urbani A. Direct Assessment of Plasma/Serum Sample Quality for Proteomics Biomarker Investigation. Methods Mol Biol 2018; 1619:3-21. [PMID: 28674873 DOI: 10.1007/978-1-4939-7057-5_1] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Blood proteome analysis for biomarker discovery represents one of the most challenging tasks to be achieved through clinical proteomics due to the sample complexity, such as the extreme heterogeneity of proteins in very dynamic concentrations, and to the observation of proper sampling and storage conditions. Quantitative and qualitative proteomics profiling of plasma and serum could be useful both for the early detection of diseases and for the evaluation of pathological status. Two main sources of variability can affect the precision and accuracy of the quantitative experiments designed for biomarker discovery and validation. These sources are divided into two categories, pre-analytical and analytical, and are often ignored; however, they can contribute to consistent errors and misunderstanding in biomarker research. In this chapter, we review critical pre-analytical and analytical variables that can influence quantitative proteomics. According to guidelines accepted by proteomics community, we propose some recommendations and strategies for a proper proteomics analysis addressed to biomarker studies.
Collapse
Affiliation(s)
- Viviana Greco
- Proteomics and metabonomics unit, Fondazione Santa Lucia, IRCCS, Rome, Italy
| | - Cristian Piras
- Department of Veterinary Medicine, University of Milan, Milan, Italy
| | - Luisa Pieroni
- Proteomics and metabonomics unit, Fondazione Santa Lucia, IRCCS, Rome, Italy
| | - Andrea Urbani
- Proteomics and metabonomics unit, Fondazione Santa Lucia, IRCCS, Rome, Italy. .,Institute of Biochemistry and Clinical Biochemistry, Catholic University of Sacred Heart, Rome, Italy.
| |
Collapse
|
5
|
Wagner CL, Baatz JE, Newton D, Hollis BW. Analytical considerations and general diagnostic and therapeutic ramifications of milk hormones during lactation. Best Pract Res Clin Endocrinol Metab 2018; 32:5-16. [PMID: 29549960 DOI: 10.1016/j.beem.2017.11.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
In this review, we will discuss the changes that occur in the mammary gland from pregnancy to lactation and the issues surrounding the analysis of circulating and milk hormones during the stages of lactogenesis. There is a cascade of events that must occur to achieve milk synthesis, milk ejection, and successful transfer to the breastfeeding infant. The adequacy and success of this process is no small measure and the assessment of milk production, the hormones involved in this process and the ability to properly diagnose conditions and causes of low milk supply are critical for the health and well-being of the mother-infant breastfeeding dyad. The normative data that have been amassed in past decades suggest that there are certain values or circulating concentrations of milk hormones, that if lacking or low, could explain low milk supply status. Yet, in looking more closely at the tests themselves, the certainly of what constitutes "normal" can vary depending on the preanalytical conditions that the blood or milk sample were obtained, the methods used in obtaining circulating or milk concentrations, and the standardization of how that result is expressed. The standardization of these aspects of breast milk physiology are essential for providing important normative data to health care professionals and researchers and will result in more consistent findings across multi-disciplinary platforms.
Collapse
Affiliation(s)
- Carol L Wagner
- Division of Neonatology, Department of Pediatrics, Medical University of South Carolina, Charleston, SC, 29425, United States.
| | - John E Baatz
- Division of Neonatology, Department of Pediatrics, Medical University of South Carolina, Charleston, SC, 29425, United States.
| | - Danforth Newton
- Division of Neonatology, Department of Pediatrics, Medical University of South Carolina, Charleston, SC, 29425, United States.
| | - Bruce W Hollis
- Division of Neonatology, Department of Pediatrics, Medical University of South Carolina, Charleston, SC, 29425, United States.
| |
Collapse
|
6
|
Ialongo C, Bernardini S. Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations. Biochem Med (Zagreb) 2017; 27:177-191. [PMID: 28392739 PMCID: PMC5382842 DOI: 10.11613/bm.2017.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Accepted: 11/25/2016] [Indexed: 11/12/2022] Open
Abstract
Phlebotomy is often addressed as a crucial process in the pre-analytical phase, in which a large part of laboratory errors take place, but to date there is not yet a consolidated methodological paradigm. Seeking literature, we found 36 suitable investigations issued between 1996 and 2016 (April) dealing with the investigation of pre-analytical factors related to phlebotomy. We found that the largest part of studies had a cohort of healthy volunteers (22/36) or outpatients (11/36), with the former group showing a significantly smaller median sample size (N = 20, IQR: 17.5-30 and N = 88, IQR: 54.5-220.5 respectively, P < 0.001). Moreover, the largest part investigated one pre-analytical factor (26/36) and regarded more than one laboratory test (29/36), and authors preferably used paired Student’s t-test (17/36) or Wilcoxon’s test (11/36), but calibration (i.e. sample size calculation for a detectable effect) was addressed only in one manuscript. The Bland-Altman plot was often the preferred method used to estimate bias (12/36), as well as the Passing-Bablok regression for agreement (8/36). However, often papers did assess neither bias (12/36) nor agreement (24/36). Clinical significance of bias was preferably assessed comparing to a database value (16/36), and it resulted uncorrelated with the size of the effect produced by the factor (P = 0.142). However, the median effect size (ES) resulted significantly larger if the associated factor was clinically significant instead of non-significant (ES = 1.140, IQR: 0.815-1.700 and ES = 0.349, IQR: 0.228-0.531 respectively, P < 0.001). On these evidences, we discussed some recommendations for improving methodological consistency, delivering reliable results, as well as ensuring accessibility to practical evidences.
Collapse
Affiliation(s)
- Cristiano Ialongo
- Department of Human Physiology and Pharmacology, University of Rome Sapienza, Rome, Italy; Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy
| | - Sergio Bernardini
- Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy; Experimental Medicine and Surgery Department, "Tor Vergata" University, Rome, Italy
| |
Collapse
|
7
|
Causes, consequences and management of sample hemolysis in the clinical laboratory. Clin Biochem 2017; 50:1317-1322. [DOI: 10.1016/j.clinbiochem.2017.09.013] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2017] [Revised: 09/13/2017] [Accepted: 09/18/2017] [Indexed: 12/15/2022]
|
8
|
Handling the altered test results of hemolyzed samples. Recommendations of the Quality, Management, Safety and Evidence Committee (CCGSE) of the Spanish Association of Medical Biopathology and Laboratory Medicine (AEBM-ML). ACTA ACUST UNITED AC 2017; 56:e1-e4. [DOI: 10.1515/cclm-2017-0354] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Accepted: 05/08/2017] [Indexed: 12/16/2022]
|
9
|
Giavarina D, Lippi G. Blood venous sample collection: Recommendations overview and a checklist to improve quality. Clin Biochem 2017; 50:568-573. [PMID: 28242283 DOI: 10.1016/j.clinbiochem.2017.02.021] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 02/18/2017] [Accepted: 02/24/2017] [Indexed: 12/26/2022]
Abstract
The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception.
Collapse
Affiliation(s)
| | - Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, Verona, Italy
| |
Collapse
|
10
|
Recomendación del uso de ecuaciones de corrección de valores de potasio en presencia de interferencia por hemólisis. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/j.labcli.2016.04.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Ialongo C, Bernardini S. Phlebotomy, a bridge between laboratory and patient. Biochem Med (Zagreb) 2016; 26:17-33. [PMID: 26981016 PMCID: PMC4783087 DOI: 10.11613/bm.2016.002] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2015] [Accepted: 12/06/2015] [Indexed: 12/28/2022] Open
Abstract
The evidence-based paradigm has changed and evolved medical practice. Phlebotomy, which dates back to the age of ancient Greece, has gained experience through the evolution of medicine becoming a fundamental diagnostic tool. Nowadays it connects the patient with the clinical laboratory dimension building up a bridge. However, more often there is a gap between laboratory and phlebotomist that causes misunderstandings and burdens on patient safety. Therefore, the scope of this review is delivering a view of modern phlebotomy to "bridge" patient and laboratory. In this regard the paper describes devices, tools and procedures in the light of the most recent scientific findings, also discussing their impact on both quality of blood testing and patient safety. It also addresses the issues concerning medical aspect of venipuncture, like the practical approach to the superficial veins anatomy, as well as the management of the patient's compliance with the blood draw. Thereby, the clinical, technical and practical issues are treated with the same relevance throughout the entire paper.
Collapse
Affiliation(s)
- Cristiano Ialongo
- Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy
| | - Sergio Bernardini
- Laboratory Medicine Department, "Tor Vergata" University Hospital, Rome, Italy; Experimental Medicine and Surgery Department, "Tor Vergata" University, Rome, Italy
| |
Collapse
|
12
|
Penn AM, Lu L, Chambers AG, Balshaw RF, Morrison JL, Votova K, Wood E, Smith DS, Lesperance M, del Zoppo GJ, Borchers CH. Exploring phlebotomy technique as a pre-analytical factor in proteomic analyses by mass spectrometry. Genome 2015; 58:569-76. [PMID: 26484650 DOI: 10.1139/gen-2015-0036] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Multiple reaction monitoring mass spectrometry (MRM-MS) is an emerging technology for blood biomarker verification and validation; however, the results may be influenced by pre-analytical factors. This exploratory study was designed to determine if differences in phlebotomy techniques would significantly affect the abundance of plasma proteins in an upcoming biomarker development study. Blood was drawn from 10 healthy participants using four techniques: (1) a 20-gauge IV with vacutainer, (2) a 21-gauge direct vacutainer, (3) an 18-gauge butterfly with vacutainer, and (4) an 18-gauge butterfly with syringe draw. The abundances of a panel of 122 proteins (117 proteins, plus 5 matrix metalloproteinase (MMP) proteins) were targeted by LC/MRM-MS. In addition, complete blood count (CBC) data were also compared across the four techniques. Phlebotomy technique significantly affected 2 of the 11 CBC parameters (red blood cell count, p = 0.010; hemoglobin concentration, p = 0.035) and only 12 of the targeted 117 proteins (p < 0.05). Of the five MMP proteins, only MMP7 was detectable and its concentration was not significantly affected by different techniques. Overall, most proteins in this exploratory study were not significantly influenced by phlebotomy technique; however, a larger study with additional patients will be required for confirmation.
Collapse
Affiliation(s)
- Andrew M Penn
- a Department of Neurosciences, Stroke Rapid Assessment Unit (SRAU), Island Health, 1 Hospital Way, Victoria, BC V8Z 6R5, Canada
| | - Linghong Lu
- b Department of Research and Capacity Building, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada
| | - Andrew G Chambers
- c University of Victoria, Genome British Columbia Proteomics Centre, Vancouver Island Technology Park, #3101 - 4464 Markham St., Victoria, BC V8Z 7X8, Canada
| | - Robert F Balshaw
- d BC Centre for Disease Control, 655 West 12th Avenue, Vancouver, BC V5Z 4R4, Canada
| | - Jaclyn L Morrison
- b Department of Research and Capacity Building, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada
| | - Kristine Votova
- b Department of Research and Capacity Building, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada
| | - Eileen Wood
- e Department of Laboratory Medicine, Pathology and Medical Genetics, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada
| | - Derek S Smith
- c University of Victoria, Genome British Columbia Proteomics Centre, Vancouver Island Technology Park, #3101 - 4464 Markham St., Victoria, BC V8Z 7X8, Canada
| | - Maria Lesperance
- b Department of Research and Capacity Building, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada
| | - Gregory J del Zoppo
- f Division of Hematology/Department of Medicine, Department of Neurology, University of Washington School of Medicine, 1959 N.E. Pacific Street, Seattle, WA 98195, USA
| | - Christoph H Borchers
- b Department of Research and Capacity Building, Island Health, 1952 Bay Street, Victoria, BC V8R 1J8, Canada.,c University of Victoria, Genome British Columbia Proteomics Centre, Vancouver Island Technology Park, #3101 - 4464 Markham St., Victoria, BC V8Z 7X8, Canada.,g Department of Biochemistry and Microbiology, University of Victoria, Petch Building Room 207, 3800 Finnerty Rd., Victoria, BC V8P 5C2, Canada
| | | |
Collapse
|
13
|
Nair VS, Pritchard CC, Tewari M, Ioannidis JPA. Design and Analysis for Studying microRNAs in Human Disease: A Primer on -Omic Technologies. Am J Epidemiol 2014; 180:140-52. [PMID: 24966218 PMCID: PMC4082346 DOI: 10.1093/aje/kwu135] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2014] [Accepted: 04/30/2014] [Indexed: 12/18/2022] Open
Abstract
microRNAs (miRNAs) are fundamental to cellular biology. Although only approximately 22 bases long, miRNAs regulate complex processes in health and disease, including human cancer. Because miRNAs are highly stable in circulation when compared with several other classes of nucleic acids, they have generated intense interest as clinical biomarkers in diverse epidemiologic studies. As with other molecular biomarker fields, however, miRNA research has become beleaguered by pitfalls related to terminology and classification; procedural, assay, and study cohort heterogeneity; and methodological inconsistencies. Together, these issues have led to both false-positive and potentially false-negative miRNA associations. In this review, we summarize the biological rationale for studying miRNAs in human disease with a specific focus on circulating miRNAs, which highlight some of the most challenging topics in the field to date. Examples from lung cancer are used to illustrate the potential utility and some of the pitfalls in contemporary miRNA research. Although the field is in its infancy, several important lessons have been learned relating to cohort development, sample preparation, and statistical analysis that should be considered for future studies. The goal of this primer is to equip epidemiologists and clinical researchers with sound principles of study design and analysis when using miRNAs.
Collapse
Affiliation(s)
| | | | | | - John P. A. Ioannidis
- Correspondence to Dr. John P. A. Ioannidis, Stanford University School of Medicine, Stanford Prevention Research Center, 1265 Welch Road, MSOB X306, Stanford, CA 94305 ()
| |
Collapse
|
14
|
Upreti S, Upreti S, Bansal R, Jeelani N, Bharat V. Types and frequency of preanalytical errors in haematology lab. J Clin Diagn Res 2013; 7:2491-3. [PMID: 24392380 DOI: 10.7860/jcdr/2013/6399.3587] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2013] [Accepted: 08/23/2013] [Indexed: 11/24/2022]
Abstract
AIM This study was conducted to evaluate the frequency of the preanalytical errors occurring in a haematology laboratory. MATERIAL AND METHODS A retrospective study was conducted by collecting and analyzing data in duration of one year in the haematology section of the laboratory. Data for all the preanalytical variables according to the predefined categories were scanned. Both IPD and OPD patients were segregated. RESULT A total of 135808 samples were received in haematology lab during this period, out of which in 1339 samples, preanalytical errors were found, which approximately constituted 1 % of all samples. CONCLUSION Highest number of samples were rejected due to misidentification, that is 0.35 % and least number were rejected due to dilution of the samples, that is 0.04 %.
Collapse
Affiliation(s)
- Shashi Upreti
- Assistant Professor , Department of Pathology, Subharti Medical College , Meerut, U.P., India
| | - Sanjay Upreti
- Assistant Professor, Department of Pathology, Subharti Medical College , Meerut, U.P., India
| | - Rani Bansal
- Professor & Head, Department of Pathology, Subharti Medical College , Meerut, U.P., India
| | - Nadia Jeelani
- Post Graduate Student, Department of Pathology, Subharti Medical College , Meerut, U.P., India
| | - Vinay Bharat
- Assistant Professor, Department of Pathology, Subharti Medical College , Meerut, U.P., India
| |
Collapse
|
15
|
Lippi G, Avanzini P, Musa R, Sandei F, Aloe R, Cervellin G. Evaluation of sample hemolysis in blood collected by S-Monovette using vacuum or aspiration mode. Biochem Med (Zagreb) 2013; 23:64-9. [PMID: 23457766 PMCID: PMC3900093 DOI: 10.11613/bm.2013.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the "vacuum" or "aspiration" mode. MATERIALS AND METHODS The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. RESULTS In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. CONCLUSIONS Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.
Collapse
Affiliation(s)
- Giuseppe Lippi
- U.O. di Diagnostica Ematochimica, Dipartimento di Patologia e Medicina di Laboratorio, Azienda Ospedaliero-Universitaria di Parma, Italy.
| | | | | | | | | | | |
Collapse
|
16
|
Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Picheth G, Guidi GC. Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - procedures for the collection of diagnostic blood specimens by venipuncture. Biochem Med (Zagreb) 2012; 22:342-51. [PMID: 23092065 PMCID: PMC3900046 DOI: 10.11613/bm.2012.036] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Introduction: The activities involving phlebotomy, a critical task for obtaining diagnostic blood samples, are poorly studied as regards the major sources of errors and the procedures related to laboratory quality control. The aim of this study was to verify the compliance with CLSI documents of clinical laboratories from South America and to assess whether teaching phlebotomists to follow the exact procedure for blood collection by venipuncture from CLSI/NCCLS H03-A6 - Procedures for the Collection of Diagnostic Blood Specimens by Venipuncture might improve the quality of the process. Materials and methods: A survey was sent by mail to 3674 laboratories from South America to verify the use of CLSI documents. Thirty skilled phlebotomists were trained with the CLSI H03-A6 document to perform venipuncture procedures for a period of 20 consecutive working days. The overall performances of the phlebotomists were further compared before and after the training program. Results: 2622 from 2781 laboratories that did answer our survey used CLSI documents to standardize their procedures and process. The phlebotomists’ training for 20 days before our evaluation completely eliminated non-conformity procedures for: i) incorrect friction of the forearm, during the cleaning of the venipuncture site to ease vein location; ii) incorrect sequence of vacuum tubes collection; and iii) inadequate mixing of the blood in primary vacuum tubes containing anticoagulants or clot activators. Unfortunately the CLSI H03-A6 document does not caution against both unsuitable tourniquet application time (i.e., for more than one minute) and inappropriate request to clench the fist repeatedly. These inadequate procedures were observed for all phlebotomists. Conclusion: We showed that strict observance of the CLSI H03-A6 document can remarkably improve quality, although the various steps for collecting diagnostic blood specimens are not a gold standard, since they may still permit errors. Tourniquet application time and forearm clench should be verified by all quality laboratory managers in the services. Moreover, the procedure for collecting blood specimens should be revised to eliminate this source of laboratory variability and safeguard the quality.
Collapse
Affiliation(s)
- Gabriel Lima-Oliveira
- Laboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, Verona, Italy.
| | | | | | | | | | | |
Collapse
|
17
|
Random variation and systematic error caused by various preanalytical variables, estimated by linear mixed-effects models. Clin Chim Acta 2012; 415:196-201. [PMID: 23117035 DOI: 10.1016/j.cca.2012.10.045] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2012] [Revised: 10/16/2012] [Accepted: 10/17/2012] [Indexed: 11/20/2022]
Abstract
BACKGROUND We wanted to determine whether specific, preanalytical sample handling increases preanalytical variation and bias test results compared with optimal handling. METHODS Blood was collected into 4 serum-separation tubes from each arm of 60 outpatients. In 30 of the patients, half of the tubes were transported in the pneumatic tube system, while the other half were manually delivered. In the remaining patients, the blood samples were collected using 21-gauge straight needles (green needles) and 23-gauge butterfly needles. Half of the tubes were mixed by inverting 5-6 times, and the other half by one inversion. Linear mixed-effects models were used as statistical method. RESULTS Transporting samples in the pneumatic tube system caused a significant bias to the results for LD (4.5 U/L, p<0.001) and magnesium (0.0021 mmol/L, p=0.003). For CK and glucose, the preanalytical variation was significantly higher for samples transported in the pneumatic tube system vs manual delivery. Using butterfly needles resulted in lower values (p<0.05) for calcium (-0.0072 mmol/L), CK (-0.75 U/L) and LD (-1.6 U/L) compared with 21-gauge needles. The preanalytical variation for ALP was significantly higher with butterfly needles. CONCLUSIONS The specific sample handling had significant but small random and systematic effects on results for some analytes.
Collapse
|
18
|
Lancé MD, Kuiper GJ, Sloep M, Spronk HM, van Oerle R, ten Cate H, Marcus MA, Henskens YM. The effects of pneumatic tube system transport on ROTEM analysis and contact activation assessed by thrombin generation test. Thromb Res 2012; 130:e147-50. [DOI: 10.1016/j.thromres.2012.05.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2012] [Revised: 04/30/2012] [Accepted: 05/02/2012] [Indexed: 10/28/2022]
|
19
|
Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Poli G, Solero GP, Picheth G, Guidi GC. K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing. ISRN HEMATOLOGY 2012; 2012:875357. [PMID: 22888448 PMCID: PMC3409519 DOI: 10.5402/2012/875357] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Accepted: 06/10/2012] [Indexed: 11/23/2022]
Abstract
Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.
Collapse
Affiliation(s)
- Gabriel Lima-Oliveira
- Laboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona, 37129 Verona, Italy
| | | | | | | | | | | | | | | |
Collapse
|
20
|
Lista S, Faltraco F, Hampel H. Biological and methodical challenges of blood-based proteomics in the field of neurological research. Prog Neurobiol 2012; 101-102:18-34. [PMID: 22743551 DOI: 10.1016/j.pneurobio.2012.06.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2011] [Revised: 03/28/2012] [Accepted: 06/18/2012] [Indexed: 12/17/2022]
Abstract
Biomarker discovery is an application of major importance in today's proteomic research. There is an urgent need for suitable biomarkers to improve diagnostic tools and treatment in various neurological diseases, such as neurodegenerative disorders. Recent years have witnessed an enormous interest in proteomics, which is currently seen as an invaluable tool to shed more light on complex interacting signalling pathways and molecular networks involved in several neuropathological conditions. However, while first results of proteomic research studies have sparked much public attention, the momentum of further proteomic biomarker research in neurological disorders may suffer by its very complex methodology which is sensitive to various sources of artefacts. A major source of variability is proteome perturbation caused by sample handling/preservation (preanalytical phase) and processing/measurement (analytical phase). The aim of the present review is to summarize the current literature focusing on the crucial role played by preanalytical and analytical factors that affect the quality of samples and the reliability of the data produced in blood-based proteomic biomarker research in neurology, which may apply to Alzheimer's disease (AD) as well as other neurological disorders. Procedures for sample preparation and protocols for the analysis of serum and plasma samples will be delineated. Finally, the potential usefulness of bioinformatics--allowing for the assembly, store, and processing of data--as well as its contribution to the execution of proteomic studies will be critically discussed.
Collapse
Affiliation(s)
- Simone Lista
- Department of Psychiatry, Psychosomatic Medicine and Psychotherapy, Goethe-University of Frankfurt, Frankfurt am Main, Germany.
| | | | | |
Collapse
|
21
|
Knapp DW. Ultrasound-guided endoscopic diode laser ablation in dogs with transitional cell carcinoma. J Am Vet Med Assoc 2012; 240:802; author reply 802-3. [PMID: 22443431 DOI: 10.2460/javma.240.7.802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
22
|
Lacroix R, Judicone C, Poncelet P, Robert S, Arnaud L, Sampol J, Dignat-George F. Impact of pre-analytical parameters on the measurement of circulating microparticles: towards standardization of protocol. J Thromb Haemost 2012; 10:437-46. [PMID: 22212198 DOI: 10.1111/j.1538-7836.2011.04610.x] [Citation(s) in RCA: 283] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
BACKGROUND Microparticles (MP) are small vesicles of 0.1-1 μm, released in response to activation or apoptosis. Over the past decade, they received an increasing interest both as biomarkers and biovectors in coagulation, inflammation and cancer. Clinical studies were conducted to assess their contribution to the identification of patients at cardiovascular risk. However, among the limitation of such studies, pre-analytical steps remains an important source of variability and artifacts in MP analysis. OBJECTIVES Because data from the literature are insufficient to establish recommendations, the objective of the present study was to assess the impact of various pre-analytical parameters on MP measurement. These parameters included the type of collection tube, phlebotomy conditions, transportation practices, centrifugation steps and freezing. METHODS MP were assessed by three methods: flow cytometry using a standardized approach, a thrombin generation test (Calibrated Automated Thrombogram(®)) and a procoagulant phospholipid-dependent clotting time assay (STA(®) -Procoag-PPL). RESULTS The main results show that the three major pre-analytical parameters which impact on MP-related data are the delay before the first centrifugation, agitation of the tubes during transportation and the centrifugation protocol. CONCLUSIONS Based on both this work and literature data, we propose a new protocol that needs to be validated on a larger scale before being applied for multicenter studies.
Collapse
Affiliation(s)
- R Lacroix
- UMR1076 INSERM-Aix-Marseille Université, UFR de Pharmacie, Marseille, France
| | | | | | | | | | | | | |
Collapse
|
23
|
LIPPI G, MUSA R, AVANZINI P, ALOE R, PIPITONE S, SANDEI F. Influence of in vitro hemolysis on hematological testing on Advia 2120. Int J Lab Hematol 2011; 34:179-84. [DOI: 10.1111/j.1751-553x.2011.01378.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
24
|
Stauss M, Sherman B, Pugh L, Parone D, Looby-Rodriguez K, Bell A, Reed CR. Hemolysis of coagulation specimens: a comparative study of intravenous draw methods. J Emerg Nurs 2010; 38:15-21. [PMID: 22226132 DOI: 10.1016/j.jen.2010.08.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2010] [Revised: 08/02/2010] [Accepted: 08/10/2010] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Hemolysis of blood samples creates significant delays in the treatment and disposition of patients in the emergency department. The purpose of this study was to compare the hemolysis rates of coagulation blood samples obtained during insertion of an intravenous (IV) catheter without (group 1) or with (group 2) extension tubing connected to the IV catheter hub. A secondary purpose of this study was to determine whether the investigators could predict whether a coagulation sample was hemolyzed based on visual observation during the specimen withdrawal process. METHODS A prospective, 2-group randomized comparative design was used to determine which method of blood collection for coagulation specimens provided the lowest hemolysis rate. This study was conducted in an urban level I emergency department averaging 58,000 visits per year. The sample consisted of 121 adult ED patients randomly assigned to 1 of the 2 groups. Data collectors were trained in the 2 methods of coagulation sample collection and followed a strict protocol. The clinical laboratory used a standardized color-coded scale to determine hemolysis. RESULTS Pearson χ(2) analysis was used to test for differences between all nominal variables. The level of significance for all tests was P < .05. There was no significant difference in hemolysis rates between the groups by use of χ(2) analysis (P = .84). Nurses were significantly more likely to predict that a sample was hemolyzed when it was not and to think that it was not hemolyzed when in fact it was (P < .001). DISCUSSION High hemolysis rates occurred equally when coagulation blood samples were drawn via a peripheral IV catheter either at the hub or through extension tubing. Emergency nurse investigators could not accurately predict by visualization whether a coagulation sample was hemolyzed at the time of blood withdrawal. Venipuncture as the preferred method of blood draw is an industry recommendation. This method has been shown in prior experimental studies to reduce hemolysis rates to less than 4%. Therefore, if hemolysis rates are a concern, one should consider obtaining blood whenever possible through a venipuncture rather than through an IV catheter. Replication studies are needed to determine whether the findings of this study can be generalized to the larger population.
Collapse
|
25
|
Favaloro EJ, Lippi G. Laboratory reporting of hemostasis assays: the final post-analytical opportunity to reduce errors of clinical diagnosis in hemostasis? Clin Chem Lab Med 2010; 48:309-21. [PMID: 20014957 DOI: 10.1515/cclm.2010.061] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The advent of modern instrumentation, with associated improvements in test performance and reliability, together with appropriate internal quality control (IQC) and external quality assurance (EQA) measures, has led to substantial reductions in analytical errors within hemostasis laboratories. Unfortunately, the reporting of incorrect or inappropriate test results still occurs, perhaps even as frequently as in the past. Many of these cases arise due to a variety of events largely outside the control of the laboratories performing the tests. These events are primarily preanalytical, related to sample collection and processing, but can also include post-analytical events related to the reporting and interpretation of test results. The current report provides an overview of these events, as well as guidance for prevention or minimization. In particular, we propose several strategies for the post-analytical reporting of hemostasis assays, and how this may provide the final opportunity to prevent serious clinical errors in diagnosis. This report should be of interest to both the laboratory scientists working in hemostasis and clinicians that request and attempt to interpret the test results. Laboratory scientists are ultimately responsible for these test results, and there is a duty to provide both accurate and precise results to enable clinicians to manage patients appropriately and to avoid the need to recollect and retest. Also, clinicians will not be in a position to best diagnose and manage their patient unless they gain an appreciation of these issues.
Collapse
Affiliation(s)
- Emmanuel J Favaloro
- Department of Hematology, Institute of Clinical Pathology and Medical Research ICPMR, Westmead Hospital, SWAHS, Westmead, NSW, Australia.
| | | |
Collapse
|
26
|
Bowen RAR, Hortin GL, Csako G, Otañez OH, Remaley AT. Impact of blood collection devices on clinical chemistry assays. Clin Biochem 2009; 43:4-25. [PMID: 19822139 DOI: 10.1016/j.clinbiochem.2009.10.001] [Citation(s) in RCA: 125] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2009] [Revised: 09/30/2009] [Accepted: 10/02/2009] [Indexed: 11/29/2022]
Abstract
Blood collection devices interact with blood to alter blood composition, serum, or plasma fractions and in some cases adversely affect laboratory tests. Vascular access devices may release coating substances and exert shear forces that lyse cells. Blood-dissolving tube additives can affect blood constituent stability and analytical systems. Blood tube stoppers, stopper lubricants, tube walls, surfactants, clot activators, and separator gels may add materials, adsorb blood components, or interact with protein and cellular components. Thus, collection devices can be a major source of preanalytical error in laboratory testing. Device manufacturers, laboratory test vendors, and clinical laboratory personnel must understand these interactions as potential sources of error during preanalytical laboratory testing. Although the effects of endogenous blood substances have received attention, the effects of exogenous substances on assay results have not been well described. This review will identify sources of exogenous substances in blood specimens and propose methods to minimize their impact on clinical chemistry assays.
Collapse
Affiliation(s)
- Raffick A R Bowen
- Department of Pathology, Stanford University, 300 Pasteur Drive, Room H1507 B, Stanford, CA 94305, USA.
| | | | | | | | | |
Collapse
|
27
|
Apweiler R, Aslanidis C, Deufel T, Gerstner A, Hansen J, Hochstrasser D, Kellner R, Kubicek M, Lottspeich F, Maser E, Mewes HW, Meyer HE, Müllner S, Mutter W, Neumaier M, Nollau P, Nothwang HG, Ponten F, Radbruch A, Reinert K, Rothe G, Stockinger H, Tarnok A, Taussig MJ, Thiel A, Thiery J, Ueffing M, Valet G, Vandekerckhove J, Verhuven W, Wagener C, Wagner O, Schmitz G. Approaching clinical proteomics: current state and future fields of application in fluid proteomics. Clin Chem Lab Med 2009; 47:724-44. [DOI: 10.1515/cclm.2009.167] [Citation(s) in RCA: 98] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
28
|
Vissers D, Matthyssen B, Truijen S, Blommaert S, Van De Velde K, Van Gaal L. Fainting and hemolysis during blood sampling in youngsters: Prevalence study. Int J Nurs Stud 2008; 45:760-4. [PMID: 17331515 DOI: 10.1016/j.ijnurstu.2006.12.014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2006] [Revised: 11/28/2006] [Accepted: 12/21/2006] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To assess the incidence of fainting and hemolysis in taking blood samples from adolescents in a school setting. DESIGN A cross-sectional school-based survey. All blood samples and data were collected during September and October 2005. SUBJECTS A community sample of 869 youngsters attending third grade secondary education in 14 secondary schools in the Flemish province of Antwerp, Belgium (mean age: 17.3 years, +/-1.2 years). MEASUREMENTS Fasting blood samples were obtained on-site for measurement of levels of glucose, high density lipoprotein cholesterol and triglycerides. The incidence of fainting and hemolysis was assessed. RESULTS In 60% of the total sample a blood sample was taken, 15% refused. In the remaining 25%, taking a blood sample was not possible due to problems in drawing blood from the vein (4%) or not fasting (21%). The incidence of fainting was 2.5%. Hemolysis occurred in 2.4% of the blood samples. CONCLUSION When taking blood samples in this age group, there seems to be a great willingness to participate. Precaution should be taken though when taking blood samples in youngsters. In this study, about 1 in 40 students fainted. When blood samples are taken on-site and transported to a laboratory, an incidence of hemolysis of 2.4% should be taken into account.
Collapse
Affiliation(s)
- Dirk Vissers
- University College of Antwerp, Department of Health Sciences-Nursing and Physiotherapy, Antwerp, Belgium.
| | | | | | | | | | | |
Collapse
|
29
|
The cost-benefit ratio of screening pregnant women for thrombophilia. BLOOD TRANSFUSION = TRASFUSIONE DEL SANGUE 2007; 5:189-203. [PMID: 19204775 DOI: 10.2450/2007.0022-07] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Subscribe] [Scholar Register] [Received: 05/16/2007] [Accepted: 06/07/2007] [Indexed: 11/21/2022]
|
30
|
Khan SY, Kelher MR, Heal JM, Blumberg N, Boshkov LK, Phipps R, Gettings KF, McLaughlin NJ, Silliman CC. Soluble CD40 ligand accumulates in stored blood components, primes neutrophils through CD40, and is a potential cofactor in the development of transfusion-related acute lung injury. Blood 2006; 108:2455-62. [PMID: 16772606 PMCID: PMC1895564 DOI: 10.1182/blood-2006-04-017251] [Citation(s) in RCA: 316] [Impact Index Per Article: 17.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Transfusion-related acute lung injury (TRALI) is a form of posttransfusion acute pulmonary insufficiency that has been linked to the infusion of biologic response modifiers (BRMs), including antileukocyte antibodies and lipids. Soluble CD40 ligand (sCD40L) is a platelet-derived proinflammatory mediator that accumulates during platelet storage. We hypothesized that human polymorpho-nuclear leukocytes (PMNs) express CD40, CD40 ligation rapidly primes PMNs, and sCD40L induces PMN-mediated cytotoxicity of human pulmonary microvascular endothelial cells (HMVECs). Levels of sCD40L were measured in blood components and in platelet concentrates (PCs) implicated in TRALI or control PCs that did not elicit a transfusion reaction. All blood components contained higher levels of sCD40L than fresh plasma, with apheresis PCs evidencing the highest concentration of sCD40L followed by PCs from whole blood, whole blood, and packed red blood cells (PRBCs). PCs implicated in TRALI reactions contained significantly higher sCD40L levels than control PCs. PMNs express functional CD40 on the plasma membrane, and recombinant sCD40L (10 ng/mL-1 mug/mL) rapidly (5 minutes) primed the PMN oxidase. Soluble CD40L promoted PMN-mediated cytotoxicity of HMVECs as the second event in a 2-event in vitro model of TRALI. We concluded that sCD40L, which accumulates during blood component storage, has the capacity to activate adherent PMNs, causing endothelial damage and possibly TRALI in predisposed patients.
Collapse
|
31
|
Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med 2006; 44:311-6. [PMID: 16519604 DOI: 10.1515/cclm.2006.054] [Citation(s) in RCA: 191] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Abstract
Collapse
Affiliation(s)
- Giuseppe Lippi
- Istituto di Chimica e Microscopia Clinica, Dipartimento di Scienze Morfologico-Biomediche, Università degli Studi di Verona, Verona, Italy.
| | | | | | | | | |
Collapse
|
32
|
Lippi G, Salvagno GL, Montagnana M, Brocco G, Cesare Guidi G. Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing. Clin Chem Lab Med 2006; 44:1009-14. [PMID: 16879070 DOI: 10.1515/cclm.2006.172] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractClin Chem Lab Med 2006;44:1009–14.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Istituto di Chimica e Microscopia Clinica, Dipartimento di Scienze Morfologico-Biomediche, Università degli Studi di Verona, Piazzale, Scuro, Verona, Italy.
| | | | | | | | | |
Collapse
|