Bonroy C, Vercammen M, Fierz W, Andrade LEC, Van Hoovels L, Infantino M, Fritzler MJ, Bogdanos D, Kozmar A, Nespola B, Broeders S, Patel D, Herold M, Zheng B, Chan EYT, Uibo R, Haapala AM, Musset L, Sack U, Nagy G, Sundic T, Fischer K, Rego de Sousa MJ, Vargas ML, Eriksson C, Heijnen I, García-De La Torre I, Carballo OG, Satoh M, Kim KH, Chan EKL, Damoiseaux J, Lopez-Hoyos M, Bossuyt X. Detection of antinuclear antibodies: recommendations from EFLM, EASI and ICAP. Clin Chem Lab Med 2023; 61:1167-1198. [PMID: 36989417 DOI: 10.1515/cclm-2023-0209] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 02/27/2023] [Indexed: 03/31/2023]
Abstract
OBJECTIVES Antinuclear antibodies (ANA) are important for the diagnosis of various autoimmune diseases. ANA are usually detected by indirect immunofluorescence assay (IFA) using HEp-2 cells (HEp-2 IFA). There are many variables influencing HEp-2 IFA results, such as subjective visual reading, serum screening dilution, substrate manufacturing, microscope components and conjugate. Newer developments on ANA testing that offer novel features adopted by some clinical laboratories include automated computer-assisted diagnosis (CAD) systems and solid phase assays (SPA). METHODS A group of experts reviewed current literature and established recommendations on methodological aspects of ANA testing. This process was supported by a two round Delphi exercise. International expert groups that participated in this initiative included (i) the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group "Autoimmunity Testing"; (ii) the European Autoimmune Standardization Initiative (EASI); and (iii) the International Consensus on ANA Patterns (ICAP). RESULTS In total, 35 recommendations/statements related to (i) ANA testing and reporting by HEp-2 IFA; (ii) HEp-2 IFA methodological aspects including substrate/conjugate selection and the application of CAD systems; (iii) quality assurance; (iv) HEp-2 IFA validation/verification approaches and (v) SPA were formulated. Globally, 95% of all submitted scores in the final Delphi round were above 6 (moderately agree, agree or strongly agree) and 85% above 7 (agree and strongly agree), indicating strong international support for the proposed recommendations. CONCLUSIONS These recommendations are an important step to achieve high quality ANA testing.
Collapse
Affiliation(s)
- Carolien Bonroy
- Department of Diagnostic Sciences, Ghent University, Ghent, Belgium
- Department of Laboratory Medicine, University Hospital Ghent, Ghent, Belgium
| | - Martine Vercammen
- Department of Laboratory Medicine, AZ Sint-Jan, Brugge, Belgium
- Research Group REIM, Vrije Universiteit Brussel, Brussels, Belgium
| | - Walter Fierz
- Schweizerischer Verband der Diagnostikindustrie (SVDI-ASID), Bern, Switzerland
| | - Luis E C Andrade
- Rheumatology Division, Escola Paulista de Medicina, Universidade Federal de Sao Paulo, Sao Paulo, Brazil
- Immunology Division, Fleury Medicine and Health Laboratories, Sao Paulo, Brazil
| | - Lieve Van Hoovels
- Department of Laboratory Medicine, OLV Hospital, Aalst, Belgium
- Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium
| | - Maria Infantino
- Immunology and Allergology Laboratory, S. Giovanni di Dio Hospital, Florence, Italy
| | - Marvin J Fritzler
- Department of Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada
| | - Dimitrios Bogdanos
- Department of Rheumatology and Clinical Immunology, Faculty of Medicine, School of Health Sciences, University of Thessaly, University General Hospital of Larissa, Larissa, Greece
| | - Ana Kozmar
- Department of Laboratory Diagnostics, University Hospital Centre Zagreb, Zagreb, Croatia
| | - Benoit Nespola
- Laboratory of Immunology, Hôpitaux Universitaires de Strasbourg, Strasbourg, France
| | | | - Dina Patel
- UK NEQAS Immunology, Immunochemistry & Allergy, Sheffield Teaching Hospitals, Sheffield, UK
| | - Manfred Herold
- Department of Internal Medicine II, Rheumatology Laboratory, Medical University of Innsbruck, Innsbruck, Austria
| | - Bing Zheng
- Department of Laboratory Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, P.R. China
| | - Eric Y T Chan
- Department of Pathology, Queen Mary Hospital, Hong Kong, P.R. China
| | - Raivo Uibo
- Department of Immunology, Medical Faculty, University of Tartu, Tartu, Estonia
| | | | - Lucile Musset
- Department of Immunology, Assistance Publique-Hôpitaux de Paris, Groupe Hospitalier Pitié-Salpêtrière, Paris, France
| | - Ulrich Sack
- Medical Faculty, Leipzig University, Leipzig, Germany
| | - Gabor Nagy
- Department of Laboratory Medicine, Faculty of Medicine, University of Debrecen, Debrecen, Hungary
| | - Tatjana Sundic
- Department of Immunology and Transfusion Medicine, Haugesund Hospital, Helse Fonna, Haugesund, Norway
| | - Katarzyna Fischer
- Individual Laboratory for Rheumatologic Diagnostics, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Maria-José Rego de Sousa
- Immunopathology and Autoimmunity Department, Centro de Medicina Laboratorial Germano de Sousa, Lisbon, Portugal
| | | | - Catharina Eriksson
- Department of Clinical Microbiology Section of Infection and Immunology, Umeå University, Umeå, Sweden
| | - Ingmar Heijnen
- Immunology, Laboratory Medicine, University Hospital Basel, Basel, Switzerland
| | - Ignacio García-De La Torre
- Department of Immunology and Rheumatology, Hospital General de Occidente, Universidad de Guadalajara, Guadalajara, Mexico
| | - Orlando Gabriel Carballo
- Laboratory of Immunology, Hospital Carlos G. Durand, Buenos Aires, Argentina
- Department of Microbiology and Immunology, Instituto Universitario, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina
| | - Minoru Satoh
- Department of Human, Information and Life Sciences, University of Occupational and Environmental Health, Kitakyushu, Japan
- Department of Medicine, Kitakyushu Yahata-Higashi Hospital, Kitakyushu, Japan
| | - Kyeong-Hee Kim
- Department of Laboratory Medicine, Dong-A University College of Medicine, Busan, Republic of Korea
| | - Edward K L Chan
- Department of Oral Biology, University of Florida, Gainesville, FL, USA
| | - Jan Damoiseaux
- Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Marcos Lopez-Hoyos
- Immunology Service, University Hospital Marques de Valdecilla-IDIVAL, University of Cantabria, Santander, Spain
| | - Xavier Bossuyt
- Department of Microbiology, Immunology and Transplantation, KU Leuven, Leuven, Belgium
- Department of Laboratory Medicine, University Hospital Leuven, Leuven, Belgium
| |
Collapse
|
2
|
Ostrov BE. Reliability and reproducibility of antinuclear antibody testing in pediatric rheumatology practice. Front Med (Lausanne) 2023; 9:1071115. [PMID: 36714114 PMCID: PMC9875300 DOI: 10.3389/fmed.2022.1071115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 12/13/2022] [Indexed: 01/11/2023] Open
Abstract
Antinuclear antibody (ANA) testing is common practice among health care practitioners when evaluating children and adolescents with non-specific symptoms including fatigue and aches and pains. When positive, ANA results often lead to referrals to pediatric rheumatologists as these antibodies may be key indicators for specific pediatric rheumatologic diagnoses. The reliability and reproducibility of ANA tests varies with assay techniques and validation and interpretation of results. In the following article, review of ANA testing in pediatrics is provided along with case examples that demonstrate the reliability and reproducibility of these results in specific scenarios common in the practice of pediatric rheumatology. Guidelines for more accurate utilization of ANA testing are presented with the aim to improve testing and interpretation by ordering clinicians.
Collapse
|
3
|
Cinquanta L, Bizzaro N, Pesce G. Standardization and Quality Assessment Under the Perspective of Automated Computer-Assisted HEp-2 Immunofluorescence Assay Systems. Front Immunol 2021; 12:638863. [PMID: 33717188 PMCID: PMC7947926 DOI: 10.3389/fimmu.2021.638863] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 01/18/2021] [Indexed: 12/11/2022] Open
Abstract
The recent availability of automated computer-assisted diagnosis (CAD) systems for the reading and interpretation of the anti-nuclear antibody (ANA) test performed with the indirect immunofluorescence (IIF) method on HEp-2 cells, has improved the reproducibility of the results and initiated a process of harmonization of this test. Furthermore, CAD systems provide quantitative expression of fluorescence intensity, allowing the introduction of objective quality control procedures to the monitoring of the entire process. The calibration of the reading systems and the automated image interpretation are essential prerequisites for obtaining reproducible and harmonized IIF test results and form the basis for standardization, regardless of the computer algorithms used in the different systems. The use of automated CAD systems, facilitating control procedures, represents a step forward for the quality certification of the laboratory.
Collapse
Affiliation(s)
- Luigi Cinquanta
- Laboratorio di Patologia Clinica, IRCCS S.D.N., Napoli, Italy
| | - Nicola Bizzaro
- Laboratorio di Patologia Clinica, Ospedale San Antonio, Tolmezzo-Azienda Sanitaria Universitaria Integrata di Udine, Udine, Italy
| | - Giampaola Pesce
- Laboratorio Diagnostico di Autoimmunologia, IRCCS Ospedale Policlinico San Martino, Genova, Italy.,Dipartimento di Medicina Interna e Specialità Mediche (DIMI), Università Degli Studi di Genova, Genova, Italy
| |
Collapse
|
4
|
Radin M, Cecchi I, Foddai SG, Rubini E, Barinotti A, Ramirez C, Seaman A, Roccatello D, Mahler M, Sciascia S. Validation of the Particle-Based Multi-Analyte Technology for Detection of Anti-PhosphatidylSerine/Prothrombin Antibodies. Biomedicines 2020; 8:biomedicines8120622. [PMID: 33348782 PMCID: PMC7766094 DOI: 10.3390/biomedicines8120622] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Revised: 12/11/2020] [Accepted: 12/14/2020] [Indexed: 11/16/2022] Open
Abstract
Among “extra-criteria” antiphospholipid (aPL) antibodies, anti-phosphatidylserine/prothrombin (aPS/PT) antibodies, are considered a part of risk assessment strategies when investigating patients suspected of having antiphospholipid syndrome (APS). aPL detection is currently performed by solid-phase assays to identify anti-cardiolipin (aCL), anti-β2glycoprotein I (aβ2GPI) and aPS/PT antibodies, but new techniques are emerging. Among these, particle-based multi-analyte technology (PMAT), which allows the full automation and simultaneous digital detection of autoantibodies and proteins, including IgG, IgA and IgM isotypes of aCL, aβ2GPI and aPS/PT. The aim of this study was to investigate the agreement of aPS/PT testing between enzyme-linked immunosorbent assay (ELISA) and the PMAT platform. A total of 94 patients were enrolled in the study, including 71 patients with confirmed APS and 23 “aPL carriers”. aPS/PT IgG showed a moderate binomial agreement between ELISA and PMAT (k = 0.57, 95% CI 0.45–0.75), and aPS/PT IgM showed a moderate agreement (k = 0.60, 95% CI 0.45–0.75). Moreover, when considering the continuous agreement, both aPS/PT IgG and IgM showed a statistically significant correlation between ELISA and PMAT (Spearman’s correlation = 0.69, p < 0.001 and 0.72, p < 0.001, respectively). This study demonstrates that PMAT technology is a reliable method for aPS/PT IgG and IgM testing when compared to the available commercial ELISA kit.
Collapse
Affiliation(s)
- Massimo Radin
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
| | - Irene Cecchi
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
| | - Silvia Grazietta Foddai
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
- School of Specialization of Clinical Pathology, Department of Clinical and Biological Sciences, University of Turin, 10125 Turin, Italy
| | - Elena Rubini
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
| | - Alice Barinotti
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
| | - Carlos Ramirez
- Inova Diagnostics, San Diego, CA 92131, USA; (C.R.); (A.S.); (M.M.)
| | - Andrea Seaman
- Inova Diagnostics, San Diego, CA 92131, USA; (C.R.); (A.S.); (M.M.)
| | - Dario Roccatello
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
- Nephrology and Dialysis, Department of Clinical and Biological Sciences, S. Giovanni Bosco Hospital, University of Turin, 10154 Turin, Italy
| | - Michael Mahler
- Inova Diagnostics, San Diego, CA 92131, USA; (C.R.); (A.S.); (M.M.)
| | - Savino Sciascia
- Center of Research of Immunopathology and Rare Diseases-Coordinating Center of Piemonte and Valle d’Aosta Network for Rare Diseases, S. Giovanni Bosco Hospital, Department of Clinical and Biological Sciences, University of Turin, 10154 Turin, Italy; (M.R.); (I.C.); (S.G.F.); (E.R.); (A.B.); (D.R.)
- Nephrology and Dialysis, Department of Clinical and Biological Sciences, S. Giovanni Bosco Hospital, University of Turin, 10154 Turin, Italy
- Correspondence: mail
| |
Collapse
|
5
|
Understanding and interpreting antinuclear antibody tests in systemic rheumatic diseases. Nat Rev Rheumatol 2020; 16:715-726. [PMID: 33154583 DOI: 10.1038/s41584-020-00522-w] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/25/2020] [Indexed: 12/12/2022]
Abstract
Antinuclear antibodies (ANAs) are valuable laboratory markers to screen for and support the diagnosis of various rheumatic diseases (known as ANA-associated rheumatic diseases). The importance of ANA testing has been reinforced by the inclusion of ANA positivity as an entry criterion in the 2019 systemic lupus erythematosus classification criteria. In addition, specific ANAs (such as antibodies to Sm, double-stranded DNA (dsDNA), SSA/Ro60, U1RNP, topoisomerase I, centromere protein B (CENPB), RNA polymerase III and Jo1) are included in classification criteria for other rheumatic diseases. A number of techniques are available for detecting antibodies to a selection of clinically relevant antigens (such as indirect immunofluorescence and solid phase assays). In this Review, we discuss the advantages and limitations of these techniques, as well as the clinical relevance of the differences between the techniques, to provide guidance in understanding and interpreting ANA test results. Such understanding not only necessitates insight into the sensitivity and specificity of each assay, but also into the importance of the disease context and antibody level. We also highlight the value of titre-specific information (such as likelihood ratios).
Collapse
|
6
|
Monogioudi E, Martos G, Sheldon J, Meroni PL, Trapmann S, Zegers I. Development of a certified reference material for anti-β2-glycoprotein I IgG - commutability studies. Clin Chem Lab Med 2020; 59:325-332. [PMID: 33001848 DOI: 10.1515/cclm-2020-0995] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 09/16/2020] [Indexed: 11/15/2022]
Abstract
Objectives In this paper, we describe the steps followed for the development of a certified reference material for immunoglobulin G antibodies against β2-glycoprotein I (also known as apolipoprotein H). These steps include processing of the material, commutability, the impact of dilution, the appropriate reconstitution conditions, homogeneity and stability during transport and storage. Methods We analysed 69 clinical samples from patients suffering from antiphospholipid syndrome with several commercial enzyme-linked immunosorbent assays (ELISA) purchased from in vitro diagnostic manufacturers. Results Analysis of the results indicated that the candidate reference material can be safely freeze-dried, and that the user should carefully follow the reconstitution instructions as small changes in e.g. temperature may have unwanted effects. The statistical analysis of the commutability studies indicated that the analytical response of the reference material upon dilution is similar to that of clinical samples, and that correlation between results may differ from assay to assay. Finally yet importantly, the presented and developed candidate reference material is commutable for most assays tested, homogeneous and stable. Conclusions Immunoglobulin G antibodies against β2-glycoprotein I are associated with a higher risk of thrombosis and pregnancy complications. Their measurement is essential for the diagnosis and monitoring of antiphospholipid syndrome. These antibodies are detected by specific immunoassays, routinely used in clinical diagnostics, but various of these methods show enormous variability, in part due to the lack of a reference material.
Collapse
Affiliation(s)
| | - Gustavo Martos
- European Commission - Joint Research Centre (JRC), Geel, Belgium.,International Bureau of Weights and Measures, Sèvres, France
| | - Joanna Sheldon
- St. George's Hospital, Protein Reference Unit, London, UK
| | - Pier Luigi Meroni
- University of Milan, IRCCS Instituto Auxologico Italiano, Milan, Italy
| | | | - Ingrid Zegers
- European Commission - Joint Research Centre (JRC), Geel, Belgium
| |
Collapse
|
7
|
A multi-centre study for standardization of antinuclear antibody indirect immunofluorescence screening with automated system. J Immunol Methods 2019; 477:112701. [PMID: 31705859 DOI: 10.1016/j.jim.2019.112701] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2019] [Revised: 11/03/2019] [Accepted: 11/04/2019] [Indexed: 12/23/2022]
Abstract
INTRODUCTION ndirect immunofluorescence assay (IFA) using HEp-2 as substrate plays a consolidate role for the detection and measurement of ANA, which is currently considered as the reference method for detection. Manual operation is still very common in China, therefore, the need of standardization and automation for ANA-IFA detecting has been highlighted. OBJECTIVE The current multi-center study is aimed to evaluate if HELIOS (AESKU Diagnostics, Wendelsheim, Germany) contributes to comparability of ANA screening results among different labs,and establish application specification of HELIOS for standardization of ANA detection. METHODS ANA detection by manual IFA method and HELIOS on 230 clinical serum samples in eight laboratories. The performance to discriminate positive/negative screening results, endpoint titer estimation and pattern recognition were evaluated in HELIOS and manual visual. RESULTS The positive coincident rate for ANA detection by manual IFA ranges from 87.7% to 97.8%, the negative coincidence rate ranges from 68.8% to 100%, the correctly estimated titer evaluation were 80 to 171 cases, the correct pattern in 146 to 161 cases, respectively. The positive coincident rate of HELIOS for ANA detection ranges from 91.2% to 97.7%, the negative coincidence rate ranges from 96.5% to 100%, the correctly estimated titer evaluation were 145 to 157 cases, the correct pattern in 123 to 140 cases, respectively. CONCLUSION HELIOS could provide accurate diagnostic results, this include not only positive/negative results, but also endpoint titer, common patterns. The application of this system can help to promote standardization of ANA detection.
Collapse
|
8
|
Damoiseaux J, Andrade LEC, Carballo OG, Conrad K, Francescantonio PLC, Fritzler MJ, Garcia de la Torre I, Herold M, Klotz W, Cruvinel WDM, Mimori T, von Muhlen C, Satoh M, Chan EK. Clinical relevance of HEp-2 indirect immunofluorescent patterns: the International Consensus on ANA patterns (ICAP) perspective. Ann Rheum Dis 2019; 78:879-889. [PMID: 30862649 PMCID: PMC6585284 DOI: 10.1136/annrheumdis-2018-214436] [Citation(s) in RCA: 184] [Impact Index Per Article: 36.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 01/23/2019] [Indexed: 12/21/2022]
Abstract
The indirect immunofluorescence assay (IIFA) on HEp-2 cells is widely used for detection of antinuclear antibodies (ANA). The dichotomous outcome, negative or positive, is integrated in diagnostic and classification criteria for several systemic autoimmune diseases. However, the HEp-2 IIFA test has much more to offer: besides the titre or fluorescence intensity, it also provides fluorescence pattern(s). The latter include the nucleus and the cytoplasm of interphase cells as well as patterns associated with mitotic cells. The International Consensus on ANA Patterns (ICAP) initiative has previously reached consensus on the nomenclature and definitions of HEp-2 IIFA patterns. In the current paper, the ICAP consensus is presented on the clinical relevance of the 29 distinct HEp-2 IIFA patterns. This clinical relevance is primarily defined within the context of the suspected disease and includes recommendations for follow-up testing. The discussion includes how this information may benefit the clinicians in daily practice and how the knowledge can be used to further improve diagnostic and classification criteria.
Collapse
Affiliation(s)
- Jan Damoiseaux
- Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands
| | | | - Orlando Gabriel Carballo
- Department of Immunology, Instituto Universitario del Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.,Laboratory of Immunology, Hospital General de Agudos Carlos G Durand, Buenos Aires, Argentina
| | - Karsten Conrad
- Immunology, Medical Faculty TU Dresden, Dresden, Germany
| | | | | | | | - Manfred Herold
- Rheumatology Unit, Clinical Department of General Internal Medicine, Innsbruck Medical University, Innsbruck, Austria
| | - Werner Klotz
- Department of Internal Medicine II, Medical University of Innsbruck, Innsbruck, Austria
| | | | - Tsuneyo Mimori
- Department of Rheumatology and Clinical Immunology, Kyoto University Graduate school of Medicine, Kyoto, Japan
| | | | - Minoru Satoh
- Department of Clinical Nursing, University of Occupational and Environmental Health, Kitakyushu, Japan
| | - Edward K Chan
- Department of Oral Biology, University of Florida, Gainesville, Florida, USA
| |
Collapse
|
9
|
Monogioudi E, Zegers I. Certified Reference Materials and their need for the diagnosis of autoimmune diseases. Mediterr J Rheumatol 2019; 30:26-32. [PMID: 32185339 PMCID: PMC7045914 DOI: 10.31138/mjr.30.1.26] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Revised: 01/22/2019] [Accepted: 01/29/2019] [Indexed: 12/24/2022] Open
Abstract
Autoantibody measurement is the chosen tool, in addition to clinical observations, for the diagnosis of autoimmune diseases. Hence, it is essential for these measurements to be reliable and in the longer run to be standardised. Due to the intrinsic variability of analytes and reagents, and the heterogeneity of the available techniques, standardisation cannot be taken for granted, and results may vary between laboratories. As a consequence, diagnoses can be missed or wrong and unnecessary costs may burden individuals and healthcare systems. Standardisation of autoantibody testing is a demanding and multi-parameter task, but could be part of the solution. So as to achieve standardisation, the development and availability of suitable certified reference materials for calibration and/or quality control is crucial.
Collapse
Affiliation(s)
| | - Ingrid Zegers
- European Commission, Joint Research Centre (JRC), Geel, Belgium
| |
Collapse
|
10
|
Monogioudi E, Martos G, Hutu DP, Schimmel H, Meroni PL, Sheldon J, Zegers I. Standardization of autoimmune testing – is it feasible? ACTA ACUST UNITED AC 2018; 56:1734-1742. [DOI: 10.1515/cclm-2017-1077] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Accepted: 03/05/2018] [Indexed: 12/11/2022]
Abstract
Abstract
Correct measurement of autoantibodies is essential for the diagnosis of autoimmune diseases. However, due to the variability of autoantibody results and the heterogeneity of testing, wrong diagnosis is a reality. For this and more reasons, harmonization of testing is of the outmost importance. In this review we have summarized the factors contributing to this variability. The ways with which the working group on harmonization of autoantibody testing of the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has been trying to tackle the issue with the production and correct use of certified reference materials (CRMs), is discussed. Finally the advantages and the limitations of the use of CRMs are presented.
Collapse
Affiliation(s)
- Evanthia Monogioudi
- European Commission – Joint Research Centre, Directorate F , Retieseweg 111 , 02440-Geel , Belgium , Phone: +32-14-571906
| | - Gustavo Martos
- European Commission – Joint Research Centre, Directorate F , Geel , Belgium
| | | | - Heinz Schimmel
- European Commission – Joint Research Centre, Directorate F , Geel , Belgium
| | - Pier Luigi Meroni
- University of Milan , IRCCS Instituto Auxologico Italiano , Milan , Italy
| | - Joanna Sheldon
- St. George’s Hospital, Protein Reference Unit , London , UK
| | - Ingrid Zegers
- European Commission – Joint Research Centre, Directorate F , Geel , Belgium
| |
Collapse
|
11
|
Sowa M, Hiemann R, Schierack P, Reinhold D, Conrad K, Roggenbuck D. Next-Generation Autoantibody Testing by Combination of Screening and Confirmation-the CytoBead® Technology. Clin Rev Allergy Immunol 2017; 53:87-104. [PMID: 27368807 PMCID: PMC5502073 DOI: 10.1007/s12016-016-8574-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Occurrence of autoantibodies (autoAbs) is a hallmark of autoimmune diseases, and the analysis thereof is an essential part in the diagnosis of organ-specific autoimmune and systemic autoimmune rheumatic diseases (SARD), especially connective tissue diseases (CTDs). Due to the appearance of autoAb profiles in SARD patients and the complexity of the corresponding serological diagnosis, different diagnostic strategies have been suggested for appropriate autoAb testing. Thus, evolving assay techniques and the continuous discovery of novel autoantigens have greatly influenced the development of these strategies. Antinuclear antibody (ANA) analysis by indirect immunofluorescence (IIF) on tissue and later cellular substrates was one of the first tests introduced into clinical routine and is still an indispensable tool for CTD serology. Thus, screening for ANA by IIF is recommended to be followed by confirmatory testing of positive findings employing different assay techniques. Given the continuous growth in the demand for autoAb testing, IIF has been challenged as the standard method for ANA and other autoAb analyses due to lacking automation, standardization, modern data management, and human bias in IIF pattern interpretation. To address these limitations of autoAb testing, the CytoBead® technique has been introduced recently which enables automated interpretation of cell-based IIF and quantitative autoAb multiplexing by addressable microbead immunoassays in one reaction environment. Thus, autoAb screening and confirmatory testing can be combined for the first time. The present review discusses the history of autoAb assay techniques in this context and gives an overview and outlook of the recent progress in emerging technologies.
Collapse
Affiliation(s)
- Mandy Sowa
- GA Generic Assays GmbH, Dahlewitz, Berlin, Germany
| | - Rico Hiemann
- Institute of Biotechnology, Faculty of Environment and Natural Sciences, Brandenburg University of Technology Cottbus-Senftenberg, Senftenberg, Germany
| | - Peter Schierack
- Institute of Biotechnology, Faculty of Environment and Natural Sciences, Brandenburg University of Technology Cottbus-Senftenberg, Senftenberg, Germany
| | - Dirk Reinhold
- Institute of Molecular and Clinical Immunology, Otto-von-Guericke-University Magdeburg, Magdeburg, Germany
| | - Karsten Conrad
- Institute of Immunology, Medical Faculty, Technical University Dresden, Dresden, Germany
| | - Dirk Roggenbuck
- GA Generic Assays GmbH, Dahlewitz, Berlin, Germany.
- Institute of Biotechnology, Faculty of Environment and Natural Sciences, Brandenburg University of Technology Cottbus-Senftenberg, Senftenberg, Germany.
| |
Collapse
|
12
|
ANA IIF Automation: Moving towards Harmonization? Results of a Multicenter Study. J Immunol Res 2017; 2017:6038137. [PMID: 28321418 PMCID: PMC5339452 DOI: 10.1155/2017/6038137] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 01/24/2017] [Accepted: 02/01/2017] [Indexed: 01/30/2023] Open
Abstract
Background. Our study aimed to investigate whether the introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis decreases the interlaboratory variability of ANA titer results. Method. Three serum samples were sent to 10 laboratories using the QUANTA-Lyser® in combination with the NOVA View®. Each laboratory performed the ANA IIF analysis 10x in 1 run and 1x in 10 different runs and determined the endpoint titer by dilution. One of the three samples had been sent in 2012, before the era of ANA IIF automation, by the Belgian National External Quality Assessment (EQA) Scheme. Harmonization was evaluated in terms of variability in fluorescence intensity (LIU) and ANA IIF titer. Results. The evaluation of the intra- and interrun LIU variability revealed a larger variability for 2 laboratories, due to preanalytical and analytical problems. Reanalysis of the EQA sample resulted in a lower titer variability. Diluted endpoint titers were similar to the estimated single well titer and the overall median titer as reported by the EQA in 2012. Conclusion. The introduction of automated microscopic analysis allows more harmonized ANA IIF reporting, provided that this totally automated process is controlled by a thorough quality assurance program, covering the total ANA IIF process.
Collapse
|
13
|
Clinical performance evaluation of a novel, automated chemiluminescent immunoassay, QUANTA Flash CTD Screen Plus. Immunol Res 2015; 61:110-6. [PMID: 25420962 DOI: 10.1007/s12026-014-8601-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
The QUANTA Flash(®) CTD Screen Plus is a chemiluminescent immunoassay (CIA) for the detection of the major antinuclear antibodies (ANA) on the BIO-FLASH(®) platform. NOVA View(®) is an automated fluorescence microscope that acquires digital images of indirect immunofluorescent assay (IFA) slides. Our goal was to evaluate the clinical performance of the two automated systems and compare their performance to that of traditional IFA. Sera from patients with systemic autoimmune rheumatic diseases (SARD, n = 178), along with disease and healthy controls (n = 204), were tested with the CTD CIA and with NOVA Lite(®) HEp-2 ANA, using both the manual method of reading the IFA slides and the NOVA View instrument. The CTD CIA showed 78.1% sensitivity for SARD, coupled with 94.1% specificity. Manual IFA and NOVA View showed somewhat higher sensitivity (81.5 and 84.8% in SARD, respectively), but significantly lower specificity (79.4 and 64.7%, respectively). Both automated systems displayed somewhat different performance, due to the different principals of ANA detection: IFA with NOVA View digital image interpretation had higher sensitivity, while the CTD CIA showed higher specificity. With the added benefits of full automation, the new CTD CIA is an attractive alternative to traditional ANA screening.
Collapse
|
14
|
Van Blerk M, Bossuyt X, Humbel R, Mewis A, Servais G, Tomasi JP, Van Campenhout C, Van Hoovels L, Vercammen M, Damoiseaux J, Coucke W, Van de Walle P. Belgian recommendations on ANA, anti-dsDNA and anti-ENA antibody testing. Acta Clin Belg 2014; 69:83-6. [PMID: 24724745 DOI: 10.1179/2295333714y.0000000010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
Abstract
Autoantibodies to nuclear antigens, i.e. antinuclear antibodies (ANA), antibodies to double-stranded DNA (dsDNA) and extractable nuclear antigens (ENA), are useful as diagnostic markers for a variety of autoimmune diseases. In March 2010, the Belgian national External Quality Assessment Scheme sent a questionnaire on ANA, anti-dsDNA and anti-ENA antibody testing designed by the Dutch EASI (European Autoimmunity Standardization Initiative) team, to all clinical laboratories performing ANA testing. Virtually all laboratories completed the questionnaire (97·7%, 127/130). This paper discusses the results of this questionnaire and provides valuable information on the state-of-the-art of ANA, anti-dsDNA and anti-ENA antibody testing as practiced in the Belgian laboratories. In addition, this work presents practical recommendations developed by the members of the advisory board of the scheme as a result of the outcome of this study.
Collapse
|
15
|
Interpretation of ANA indirect immunofluorescence test outside the darkroom using NOVA view compared to manual microscopy. J Immunol Res 2014; 2014:149316. [PMID: 24741573 PMCID: PMC3987884 DOI: 10.1155/2014/149316] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 01/03/2014] [Accepted: 01/06/2014] [Indexed: 12/25/2022] Open
Abstract
Objective. To evaluate NOVA View with focus on reading archived images versus microscope based manual interpretation of ANA HEp-2 slides by an experienced, certified medical technologist. Methods. 369 well defined sera from: 44 rheumatoid arthritis, 50 systemic lupus erythematosus, 35 scleroderma, 19 Sjögren's syndrome, and 10 polymyositis patients as well as 99 healthy controls were examined. In addition, 12 defined sera from the Centers for Disease Control and 100 random patient sera sent to ARUP Laboratories for ANA HEp-2 IIF testing were included. Samples were read using the archived images on NOVA View and compared to results obtained from manual reading. Results. At a 1 : 40/1 : 80 dilution the resulting comparison demonstrated 94.8%/92.9% positive, 97.4%/97.4% negative, and 96.5%/96.2% total agreements between manual IIF and NOVA View archived images. Agreement of identifiable patterns between methods was 97%, with PCNA and mixed patterns undetermined. Conclusion. Excellent agreements were obtained between reading archived images on NOVA View and manually on a fluorescent microscope. In addition, workflow benefits were observed which need to be analyzed in future studies.
Collapse
|
16
|
A comparative study on the reliability of an automated system for the evaluation of cell-based indirect immunofluorescence. Autoimmun Rev 2012; 11:713-6. [DOI: 10.1016/j.autrev.2011.12.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2011] [Accepted: 12/20/2011] [Indexed: 01/24/2023]
|
17
|
Jearn LH, Kim TY. Should the external quality assessment sample of antinuclear antibodies be of a typical monospecific pattern? Clin Chem Lab Med 2010; 48:1189-90. [PMID: 20441476 DOI: 10.1515/cclm.2010.215] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|