1
|
Jünger F, Rohrbach A. Making Hidden Cell Particle Interactions Visible by Thermal Noise Frequency Decomposition. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2207032. [PMID: 37337392 DOI: 10.1002/smll.202207032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 02/15/2023] [Indexed: 06/21/2023]
Abstract
Thermal noise drives cellular structures, bacteria, and viruses on different temporal and spatial scales. Their weak interactions with their environment can change on subsecond scales. However, particle interactions can be hidden or invisible-even when measured with thermal noise sensitivity, leading to misconceptions about their binding behavior. Here, it is demonstrated how invisible particle interactions at the cell periphery become visible by MHz interferometric thermal noise tracking and frequency decomposition at a spectral update rate of only 0.5 s. The particle fluctuations are analyzed in radial and lateral directions by a viscoelastic modulus G(ω,tex ) over the experiment time tex , revealing a surprisingly similar, frequency dependent response for different cell types. This response behavior can be explained by a mathematical model for molecular scale elasticity and damping. The method to reveal hidden interactions is tested at two examples: the stiffening of macrophage filopodia tips within 2 s with particle contact invisible by the fluctuation width. Second, the extent and stiffness of the soft cell glycocalyx is measured, which can be sensed by a particle only on microsecond-timescales, but which remains invisible on time-average. This concept study shows how to uncover hidden cellular interactions, if particle motions are measured at high-speed.
Collapse
Affiliation(s)
- Felix Jünger
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 102, 79110, Freiburg, Germany
| | - Alexander Rohrbach
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 102, 79110, Freiburg, Germany
- CIBSS - Centre for Integrative Biological Signaling Studies, University of Freiburg, Schänzlestr. 18, 79104, Freiburg, Germany
| |
Collapse
|
2
|
Fujiwara Y, Hirao S, Yamazaki K, Ikeda T, Minatoya K, Masumoto H. Evaluations for surrounding tissue incorporation after implantation of synthetic vascular prostheses in animal models. J Artif Organs 2021; 25:24-33. [PMID: 34145464 DOI: 10.1007/s10047-021-01283-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Accepted: 06/14/2021] [Indexed: 12/21/2022]
Abstract
Incorporation of surrounding tissues after implantation of synthetic vascular prostheses potentially varies in accordance with implanted prostheses. To evaluate post-implant tissue incorporation, we examined surgical, histological and ultrastructural findings after implantation in animal models. Three types of commercially available prostheses were tested (Gelweave™; Group G, J Graft SHIELD NEO®; Group J and Triplex®; Group T). Prostheses were implanted into Sprague-Dawley rats subcutaneously or sutured on abdominal aorta of Japanese white rabbits. The tissues were surgically examined for adhesion and were subjected to histological evaluations for cellular and tissue infiltration and ultrastructural observations by scanning electron microscopy (SEM). Group G exhibited less tendency in adhesion formation in early phase (rat: G vs J, P < 0.0001; G vs T, P < 0.0001/rabbit: G vs J, P < 0.0001; G vs T, P = 0.059). In late phase, Group J showed highest adhesion (rat: G vs J, P = 0.0004; J vs T, P = 0.015/rabbit: G vs J, P = 0.0015; J vs T, P = 0.0044). In group G, a gap was observed between implants and surrounding tissues forming capsulation, whereas other groups exhibited tissue infiltration inside of the implants wall which were also confirmed by SEM. The tissue permeation toward the implants and adhesion was positively correlated (P < 0.0001). Surrounding tissue conformation varied in accordance with the type of prostheses. It is desirable to elucidate characteristics of each prosthesis to select suitable grafts for each patient to achieve a better surgical outcome.
Collapse
Affiliation(s)
- Yasue Fujiwara
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Shingo Hirao
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
- Department of Cardiovascular Surgery, Kurashiki Central Hospital, Kurashiki, Japan
| | - Kazuhiro Yamazaki
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Tadashi Ikeda
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Kenji Minatoya
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan
| | - Hidetoshi Masumoto
- Department of Cardiovascular Surgery, Graduate School of Medicine, Kyoto University, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto, 606-8507, Japan.
| |
Collapse
|
3
|
Basoli F, Giannitelli SM, Gori M, Mozetic P, Bonfanti A, Trombetta M, Rainer A. Biomechanical Characterization at the Cell Scale: Present and Prospects. Front Physiol 2018; 9:1449. [PMID: 30498449 PMCID: PMC6249385 DOI: 10.3389/fphys.2018.01449] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 09/24/2018] [Indexed: 12/12/2022] Open
Abstract
The rapidly growing field of mechanobiology demands for robust and reproducible characterization of cell mechanical properties. Recent achievements in understanding the mechanical regulation of cell fate largely rely on technological platforms capable of probing the mechanical response of living cells and their physico–chemical interaction with the microenvironment. Besides the established family of atomic force microscopy (AFM) based methods, other approaches include optical, magnetic, and acoustic tweezers, as well as sensing substrates that take advantage of biomaterials chemistry and microfabrication techniques. In this review, we introduce the available methods with an emphasis on the most recent advances, and we discuss the challenges associated with their implementation.
Collapse
Affiliation(s)
- Francesco Basoli
- Department of Engineering, Università Campus Bio-Medico di Roma, Rome, Italy
| | | | - Manuele Gori
- Department of Engineering, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Pamela Mozetic
- Center for Translational Medicine, International Clinical Research Center, St. Anne's University Hospital, Brno, Czechia
| | - Alessandra Bonfanti
- Department of Engineering, University of Cambridge, Cambridge, United Kingdom
| | - Marcella Trombetta
- Department of Engineering, Università Campus Bio-Medico di Roma, Rome, Italy
| | - Alberto Rainer
- Department of Engineering, Università Campus Bio-Medico di Roma, Rome, Italy.,Institute for Photonics and Nanotechnologies, National Research Council, Rome, Italy
| |
Collapse
|
4
|
Firkowska-Boden I, Zhang X, Jandt KD. Controlling Protein Adsorption through Nanostructured Polymeric Surfaces. Adv Healthc Mater 2018; 7. [PMID: 29193909 DOI: 10.1002/adhm.201700995] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 10/09/2017] [Indexed: 12/11/2022]
Abstract
The initial host response to healthcare materials' surfaces after implantation is the adsorption of proteins from blood and interstitial fluids. This adsorbed protein layer modulates the biological/cellular responses to healthcare materials. This stresses the significance of the surface protein assembly for the biocompatibility and functionality of biomaterials and necessitates a profound fundamental understanding of the capability to control protein-surface interactions. This review, therefore, addresses this by systematically analyzing and discussing strategies to control protein adsorption on polymeric healthcare materials through the introduction of specific surface nanostructures. Relevant proteins, healthcare materials' surface properties, clinical applications of polymer healthcare materials, fabrication methods for nanostructured polymer surfaces, amorphous, semicrystalline and block copolymers are considered with a special emphasis on the topographical control of protein adsorption. The review shows that nanostructured polymer surfaces are powerful tools to control the amount, orientation, and order of adsorbed protein layers. It also shows that the understanding of the biological responses to such ordered protein adsorption is still in its infancy, yet it has immense potential for future healthcare materials. The review, which is-as far as it is known-the first one discussing protein adsorption on nanostructured polymer surfaces, concludes with highlighting important current research questions.
Collapse
Affiliation(s)
- Izabela Firkowska-Boden
- Chair of Materials Science (CMS); Otto Schott Institute of Materials Research (OSIM); Friedrich Schiller University Jena; Löbdergraben 32 07743 Jena Germany
| | - Xiaoyuan Zhang
- Chair of Materials Science (CMS); Otto Schott Institute of Materials Research (OSIM); Friedrich Schiller University Jena; Löbdergraben 32 07743 Jena Germany
| | - Klaus D. Jandt
- Chair of Materials Science (CMS); Otto Schott Institute of Materials Research (OSIM); Friedrich Schiller University Jena; Löbdergraben 32 07743 Jena Germany
- Jena Center for Soft Matter (JCSM); Friedrich Schiller University Jena; Philosophenweg 7 07743 Jena Germany
- Jena School for Microbial Communication (JSMC); Neugasse 23 07743 Jena Germany
| |
Collapse
|
5
|
Harvesting pre-polarized macrophages using thermo-responsive substrates. Sci Rep 2017; 7:42495. [PMID: 28195152 PMCID: PMC5307341 DOI: 10.1038/srep42495] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 01/11/2017] [Indexed: 11/24/2022] Open
Abstract
In the cell culture environment macrophages are highly adherent cells. Currently used methods to harvest macrophages have the disadvantage of reducing cell viability and their ability to re-attach after seeding. Although thermo-responsive surfaces have been employed to harvest cell sheets no reports are available to use these to harvest (pre-polarized) macrophages. We show that this method significantly improves the yield of living macrophages and percentage of subsequent cell reattachment, whilst having a minimal effect on the cell phenotype.
Collapse
|
6
|
Jünger F, Kohler F, Meinel A, Meyer T, Nitschke R, Erhard B, Rohrbach A. Measuring Local Viscosities near Plasma Membranes of Living Cells with Photonic Force Microscopy. Biophys J 2016; 109:869-82. [PMID: 26331245 DOI: 10.1016/j.bpj.2015.07.027] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2014] [Revised: 07/08/2015] [Accepted: 07/17/2015] [Indexed: 11/24/2022] Open
Abstract
The molecular processes of particle binding and endocytosis are influenced by the locally changing mobility of the particle nearby the plasma membrane of a living cell. However, it is unclear how the particle's hydrodynamic drag and momentum vary locally and how they are mechanically transferred to the cell. We have measured the thermal fluctuations of a 1 μm-sized polystyrene sphere, which was placed in defined distances to plasma membranes of various cell types by using an optical trap and fast three-dimensional (3D) interferometric particle tracking. From the particle position fluctuations on a 30 μs timescale, we determined the distance-dependent change of the viscous drag in directions perpendicular and parallel to the cell membrane. Measurements on macrophages, adenocarcinoma cells, and epithelial cells revealed a significantly longer hydrodynamic coupling length of the particle to the membrane than those measured at giant unilamellar vesicles (GUVs) or a plane glass interface. In contrast to GUVs, there is also a strong increase in friction and in mean first passage time normal to the cell membrane. This hydrodynamic coupling transfers a different amount of momentum to the interior of living cells and might serve as an ultra-soft stimulus triggering further reactions.
Collapse
Affiliation(s)
- Felix Jünger
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering, University of Freiburg, Germany
| | - Felix Kohler
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering, University of Freiburg, Germany
| | - Andreas Meinel
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering, University of Freiburg, Germany
| | - Tim Meyer
- Macromolecular Modelling Group, Institute of Chemistry and Biochemistry, Freie Universität Berlin, Berlin, Germany
| | - Roland Nitschke
- Life Imaging Center (LIC) and Center for Biological Systems Analysis (ZBSA), University of Freiburg, Freiburg, Germany
| | - Birgit Erhard
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering, University of Freiburg, Germany
| | - Alexander Rohrbach
- Laboratory for Bio- and Nano-Photonics, Department of Microsystems Engineering, University of Freiburg, Germany; BIOSS Centre for Biological Signalling Studies, University of Freiburg, Freiburg, Germany.
| |
Collapse
|
7
|
Khatibzadeh N, Stilgoe AB, Bui AAM, Rocha Y, Cruz GM, Loke V, Shi LZ, Nieminen TA, Rubinsztein-Dunlop H, Berns MW. Determination of motility forces on isolated chromosomes with laser tweezers. Sci Rep 2014; 4:6866. [PMID: 25359514 PMCID: PMC4215326 DOI: 10.1038/srep06866] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2014] [Accepted: 10/13/2014] [Indexed: 12/14/2022] Open
Abstract
Quantitative determination of the motility forces of chromosomes during cell division is fundamental to understanding a process that is universal among eukaryotic organisms. Using an optical tweezers system, isolated mammalian chromosomes were held in a 1064 nm laser trap. The minimum force required to move a single chromosome was determined to be ≈ 0.8-5 pN. The maximum transverse trapping efficiency of the isolated chromosomes was calculated as ≈ 0.01-0.02. These results confirm theoretical force calculations of ≈ 0.1-12 pN to move a chromosome on the mitotic or meiotic spindle. The verification of these results was carried out by calibration of the optical tweezers when trapping microspheres with a diameter of 4.5-15 µm in media with 1-7 cP viscosity. The results of the chromosome and microsphere trapping experiments agree with optical models developed to simulate trapping of cylindrical and spherical specimens.
Collapse
Affiliation(s)
- Nima Khatibzadeh
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612, USA
| | - Alexander B Stilgoe
- School of Mathematics and Physics, The University of Queensland, St. Lucia, QLD, 4072, Australia
| | - Ann A M Bui
- School of Mathematics and Physics, The University of Queensland, St. Lucia, QLD, 4072, Australia
| | - Yesenia Rocha
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612, USA
| | - Gladys M Cruz
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612, USA
| | - Vince Loke
- School of Mathematics and Physics, The University of Queensland, St. Lucia, QLD, 4072, Australia
| | - Linda Z Shi
- Institute of Engineering in Medicine, University of California, San Diego, 9500 Gilman Drive, La Jolla, California 92093, USA
| | - Timo A Nieminen
- School of Mathematics and Physics, The University of Queensland, St. Lucia, QLD, 4072, Australia
| | | | - Michael W Berns
- 1] Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612, USA [2] Institute of Engineering in Medicine, University of California, San Diego, 9500 Gilman Drive, La Jolla, California 92093, USA
| |
Collapse
|
8
|
Beaussart A, Ngo TC, Derclaye S, Kalinova R, Mincheva R, Dubois P, Leclère P, Dufrêne YF. Chemical force microscopy of stimuli-responsive adhesive copolymers. NANOSCALE 2014; 6:565-571. [PMID: 24240173 DOI: 10.1039/c3nr05256g] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Atomic force microscopy with chemically sensitive tips was used to investigate the hydrophobic and electrostatic interaction forces of a stimuli-responsive adhesive polymer, and their dynamic changes in response to water immersion and salt concentration. Block copolymer-filled coatings were obtained by incorporating an amphiphilic block copolymer containing a polydimethylsiloxane (PDMS) block and a poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) block in a PDMS matrix. Topographic images of fresh samples revealed the presence of nanoscale domains associated with the presence of copolymers, covered by a thin layer of PDMS. Prolonged (30 days) immersion in aqueous solution led to the exposure of the hydrophilic PDMAEMA chains on the surface. Using adhesion force mapping with hydrophobic tips, we showed that fresh samples were uniformly hydrophobic, while aged samples exhibited lower surface hydrophobicity and featured nanoscale hydrophilic copolymer domains. Force mapping with negatively charged tips revealed remarkable salt-dependent force plateau signatures reflecting desorption of polyelectrolyte copolymer chains. These nanoscale experiments show how solvent-induced conformational changes of stimuli-responsive copolymers can be used to modulate surface adhesion.
Collapse
Affiliation(s)
- Audrey Beaussart
- Université catholique de Louvain, Institute of Life Sciences, Croix du Sud 1, bte L7.04.01., B-1348 Louvain-la-Neuve, Belgium.
| | | | | | | | | | | | | | | |
Collapse
|
9
|
TGFβ (transforming growth factor β) and keratocyte motility in 24 h zebrafish explant cultures. Cell Biol Int 2012; 35:1131-9. [PMID: 21729005 DOI: 10.1042/cbi20110063] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Fish keratocytes are used as a model system for the study of the mechanics of cell motility because of their characteristic rapid, smooth gliding motion, but little work has been done on the regulation of fish keratocyte movement. As TGFβ (transforming growth factor β) plays multiple roles in primary human keratinocyte cell migration, we investigated the possible involvement of TGFβ in fish keratocyte migration. Studying the involvement of TGFβ1 in 24 h keratocyte explant allows the examination of the cells before alterations in cellular physiology occur due to extended culture times. During this initial period, TGFβ levels increase 6.2-fold in SFM (serum-free medium) and 2.4-fold in SFM+2% FBS (fetal bovine serum), while TGFβ1 and TGFβRII (TGFβ receptor II) mRNA levels increase ∼3- and ∼5-fold respectively in each culture condition. Two measures of motility, cell sheet area and migration distance, vary with the amount of exogenous TGFβ1 and culture media. The addition of 100 ng/ml exogenous TGFβ1 in SFM increases both measures [3.3-fold (P = 4.5×10-5) and 26% (P = 2.1×10-2) respectively]. In contrast, 100 ng/ml of exogenous TGFβ1 in medium containing 2% FBS decreases migration distance by 2.1-fold (P = 1.7×10-7), but does not affect sheet area. TGFβ1 (10 ng/ml) has little effect on cell sheet area in SFM cultures, but leads to a 1.8-fold increase (P = 1.5×10-2) with 2% FBS. The variable response to TGFβ1 may be, at least in part, explained by the effect of 2% FBS on cell morphology, mode of motility and expression of endogenous TGFβ1 and TGFβRII. Together, these results suggest that expression of TGFβ and its receptor are up-regulated during zebrafish keratocyte explant culture and that TGFβ promotes fish keratocyte migration.
Collapse
|
10
|
Amin L, Ercolini E, Shahapure R, Bisson G, Torre V. The elementary events underlying force generation in neuronal lamellipodia. Sci Rep 2011; 1:153. [PMID: 22355669 PMCID: PMC3240973 DOI: 10.1038/srep00153] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2011] [Accepted: 10/14/2011] [Indexed: 01/26/2023] Open
Abstract
We have used optical tweezers to identify the elementary events underlying force generation in neuronal lamellipodia. When an optically trapped bead seals on the lamellipodium membrane, Brownian fluctuations decrease revealing the underlying elementary events. The distribution of bead velocities has long tails with frequent large positive and negative values associated to forward and backward jumps occurring in 0.1-0.2 ms with varying amplitudes up to 20 nm. Jump frequency and amplitude are reduced when actin turnover is slowed down by the addition of 25 nM Jasplakinolide. When myosin II is inhibited by the addition of 20 μM Blebbistatin, jump frequency is reduced but to a lesser extent than by Jasplainolide. These jumps constitute the elementary events underlying force generation.
Collapse
Affiliation(s)
- Ladan Amin
- Neurobiology Sector, International School for Advanced Studies (SISSA), IT-34136 Trieste, Italy
| | | | | | | | | |
Collapse
|
11
|
Parkin SJ, Vogel R, Persson M, Funk M, Loke VLY, Nieminen TA, Heckenberg NR, Rubinsztein-Dunlop H. Highly birefringent vaterite microspheres: production, characterization and applications for optical micromanipulation. OPTICS EXPRESS 2009; 17:21944-55. [PMID: 19997439 DOI: 10.1364/oe.17.021944] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
This paper reports on a simple synthesis and characterization of highly birefringent vaterite microspheres, which are composed of 20-30 nm sized nanocrystalls. Scanning electron microscopy shows a quite disordered assembly of nanocrystals within the microspheres. However, using optical tweezers, the effective birefringence of the microspheres was measured to be Deltan = 0.06, which compares to Deltan = 0.1 of vaterite single crystals. This suggests a very high orientation of the nanocrystals within the microspheres. A hyperbolic model of the direction of the optical axis throughout the vaterite spherulite best fits the experimental data. Results from polarized light microscopy further confirm the hyperbolic model.
Collapse
Affiliation(s)
- Simon J Parkin
- University of Queensland, School of Mathematics and Physics, Queensland, Australia
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Prestress and adhesion site dynamics control cell sensitivity to extracellular stiffness. Biophys J 2009; 96:2009-22. [PMID: 19254561 DOI: 10.1016/j.bpj.2008.10.072] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2008] [Accepted: 10/27/2008] [Indexed: 01/13/2023] Open
Abstract
This study aims at improving the understanding of mechanisms responsible for cell sensitivity to extracellular environment. We explain how substrate mechanical properties can modulate the force regulation of cell sensitive elements primarily adhesion sites. We present a theoretical and experimental comparison between two radically different approaches of the force regulation of adhesion sites that depends on their either stationary or dynamic behavior. The most classical stationary model fails to predict cell sensitivity to substrate stiffness whereas the dynamic model predicts extracellular stiffness dependence. This is due to a time dependent reaction force in response to actomyosin traction force exerted on cell sensitive elements. We purposely used two cellular models, i.e., alveolar epithelial cells and alveolar macrophages exhibiting respectively stationary and dynamic adhesion sites, and compared their sensitivity to theoretical predictions. Mechanical and structural results show that alveolar epithelial cells exhibit significant prestress supported by evident stress fibers and lacks sensitivity to substrate stiffness. On the other hand, alveolar macrophages exhibit low prestress and exhibit sensitivity to substrate stiffness. Altogether, theory and experiments consistently show that adhesion site dynamics and cytoskeleton prestress control cell sensitivity to extracellular environment with an optimal sensitivity expected in the intermediate range.
Collapse
|
13
|
Wan J, Thomas MS, Guthrie S, Vullev VI. Surface-bound proteins with preserved functionality. Ann Biomed Eng 2009; 37:1190-205. [PMID: 19308733 DOI: 10.1007/s10439-009-9673-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2007] [Accepted: 03/09/2009] [Indexed: 12/28/2022]
Abstract
Biocompatibility of materials strongly depends on their surface properties. Therefore, surface derivatization in a controllable manner provides means for achieving interfaces essential for a broad range of chemical, biological, and medical applications. Bioactive interfaces, while manifesting the activity for which they are designed, should suppress all nonspecific interaction between the supporting substrates and the surrounding media. This article describes a procedure for chemical derivatization of glass and silicon surfaces with polyethylene glycol (PEG) layers covalently functionalized with proteins. While the proteins introduce the functionality to the surfaces, the PEGs provide resistance against nonspecific interactions. For formation of aldehyde-functionalized surfaces, we coated the substrates with acetals (i.e., protected aldehydes). To avoid deterioration of the surfaces, we did not use strong mineral acids for the deprotection of the aldehydes. Instead, we used a relatively weak Lewis acid for conversion of the acetals into aldehydes. Introduction of alpha,omega-bifunctional polymers into the PEG layers, bound to the aldehydes, allowed us to covalently attach green fluorescent protein and bovine carbonic anhydrase to the surfaces. Spectroscopic studies indicated that the surface-bound proteins preserve their functionalities. The surface concentrations of the proteins, however, did not manifest linear proportionality to the molar fractions of the bifunctional PEGs used for the coatings. This finding suggests that surface-loading ratios cannot be directly predicted from the compositions of the solutions of competing reagents used for chemical derivatization.
Collapse
Affiliation(s)
- Jiandi Wan
- Department of Bioengineering, University of California, Riverside, A-220 Bourns Hall, Riverside, CA 92521, USA
| | | | | | | |
Collapse
|
14
|
Lau KHA, Bang J, Hawker CJ, Kim DH, Knoll W. Modulation of Protein−Surface Interactions on Nanopatterned Polymer Films. Biomacromolecules 2009; 10:1061-6. [DOI: 10.1021/bm801158x] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- K. H. Aaron Lau
- Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128 Mainz, Germany, Department of Chemical and Biological Engineering, Korea University, Seoul 136-701, Republic of Korea, Materials Research Laboratory, University of California at Santa Barbara, Santa Barbara, California 93106, and Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750, Republic of Korea
| | - Joona Bang
- Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128 Mainz, Germany, Department of Chemical and Biological Engineering, Korea University, Seoul 136-701, Republic of Korea, Materials Research Laboratory, University of California at Santa Barbara, Santa Barbara, California 93106, and Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750, Republic of Korea
| | - Craig J. Hawker
- Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128 Mainz, Germany, Department of Chemical and Biological Engineering, Korea University, Seoul 136-701, Republic of Korea, Materials Research Laboratory, University of California at Santa Barbara, Santa Barbara, California 93106, and Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750, Republic of Korea
| | - Dong Ha Kim
- Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128 Mainz, Germany, Department of Chemical and Biological Engineering, Korea University, Seoul 136-701, Republic of Korea, Materials Research Laboratory, University of California at Santa Barbara, Santa Barbara, California 93106, and Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750, Republic of Korea
| | - Wolfgang Knoll
- Max Planck Institute for Polymer Research, Ackermannweg 10, D-55128 Mainz, Germany, Department of Chemical and Biological Engineering, Korea University, Seoul 136-701, Republic of Korea, Materials Research Laboratory, University of California at Santa Barbara, Santa Barbara, California 93106, and Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750, Republic of Korea
| |
Collapse
|
15
|
Vicario PP, Lu ZJ, Grigorian IA, Schottman T. A lubricious formulation exhibiting reduced thrombogenicity, cell proliferation, and protein adsorption. J Biomed Mater Res B Appl Biomater 2009; 90:452-60. [PMID: 19130614 DOI: 10.1002/jbm.b.31306] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The adhesion of human platelets, erythrocytes, and leukocytes, the adsorption of protein, and the proliferation of human umbilical vein endothelial cells (HUVEC) on the surface of electropolished stainless steel and the lumen of polyurethane tubing coated with Hydromer's lubricious Duality T8B formulation was evaluated. Following exposure to a platelet-enriched suspension from citrated human whole blood, stainless steel coated with this formulation exhibited significantly reduced adhesion of platelets, erythrocytes, and granulocytes. This reduction in adhesion was confirmed using an immunohistochemical method utilizing antibodies to CD41, CD235, and CD15, respectively. The proliferation of HUVEC cells were significantly reduced when cultured on coated stainless steel. This formulation was also able to significantly reduce the adsorption of plasma proteins and the major protein in tear fluid (lysozyme) to the surface of stainless steel. The nonthrombogenic properties of Duality T8B after application to the lumen of polyurethane tubing were also examined. Following a short-term (3 h) static exposure to citrated human whole blood, microscopic examination revealed that the adhesion of platelets and erythrocytes was reduced significantly, a finding confirmed using anti-CD41 and anti-CD235 antibodies in the immunohistochemical method. A long-term (12 day) study yielded essentially identical results indicating a significant reduction in the adhesion of blood components on the luminal surface of coated polyurethane tubing. In summary, these data indicate that the application of Duality T8B onto surfaces of medical devices, such as catheters, extracorporeal circuitry, and coronary stents, could aid in reducing or preventing not only thrombus formation but also the process of restenosis.
Collapse
|
16
|
Gao Z, Wang S, Zhu H, Su C, Xu G, Lian X. Using selected uniform cells in round shape with a micropipette to measure cell adhesion strength on silk fibroin-based materials. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2008. [DOI: 10.1016/j.msec.2007.11.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Vrana NE, Liu Y, McGuinness GB, Cahill PA. Characterization of Poly(vinyl alcohol)/Chitosan Hydrogels as Vascular Tissue Engineering Scaffolds. ACTA ACUST UNITED AC 2008. [DOI: 10.1002/masy.200850913] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
18
|
Zhang H, Liu KK. Optical tweezers for single cells. J R Soc Interface 2008; 5:671-90. [PMID: 18381254 PMCID: PMC2408388 DOI: 10.1098/rsif.2008.0052] [Citation(s) in RCA: 374] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2008] [Revised: 03/17/2008] [Accepted: 03/17/2008] [Indexed: 11/12/2022] Open
Abstract
Optical tweezers (OT) have emerged as an essential tool for manipulating single biological cells and performing sophisticated biophysical/biomechanical characterizations. Distinct advantages of using tweezers for these characterizations include non-contact force for cell manipulation, force resolution as accurate as 100aN and amiability to liquid medium environments. Their wide range of applications, such as transporting foreign materials into single cells, delivering cells to specific locations and sorting cells in microfluidic systems, are reviewed in this article. Recent developments of OT for nanomechanical characterization of various biological cells are discussed in terms of both their theoretical and experimental advancements. The future trends of employing OT in single cells, especially in stem cell delivery, tissue engineering and regenerative medicine, are prospected. More importantly, current limitations and future challenges of OT for these new paradigms are also highlighted in this review.
Collapse
Affiliation(s)
| | - Kuo-Kang Liu
- Institute for Science and Technology in Medicine, Keele UniversityStoke-on-Trent ST4 7QB, UK
| |
Collapse
|
19
|
Andersson M, Madgavkar A, Stjerndahl M, Wu Y, Tan W, Duran R, Niehren S, Mustafa K, Arvidson K, Wennerberg A. Using optical tweezers for measuring the interaction forces between human bone cells and implant surfaces: System design and force calibration. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2007; 78:074302. [PMID: 17672780 DOI: 10.1063/1.2752606] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Optical tweezers were used to study the interaction and attachment of human bone cells to various types of medical implant materials. Ideally, the implant should facilitate cell attachment and promote migration of the progenitor cells in order to decrease the healing time. It is therefore of interest, in a controlled manner, to be able to monitor the cell adhesion process. Results from such studies would help foresee the clinical outcome of integrating medical implants. The interactions between two primary cell culture models, human gingival fibroblasts and bone forming human osteoblast cells, and three different implant materials, glass, titanium, and hydroxyapatite, were studied. A novel type of optical tweezers, which has a newly designed quadrant detector and a powerful 3 W laser was constructed and force calibrated using two different methods: one method in which the stiffness of the optical trap was obtained by monitoring the phase lag between the trap and the moved object when imposing a forced oscillation on the trapped object and another method in which the maximum trapping force was derived from the critical velocity at which the object escapes the trap. Polystyrene beads as well as cells were utilized for the calibrations. This is the first time that cells have been used directly for these types of force calibrations and, hence, direct measurements of forces exerted on cells can be performed, thus avoiding the difficulties often encountered when translating the results obtained from cell measurements to the calibrations obtained with reference materials. This more straightforward approach represents an advantage in comparison to established methods.
Collapse
Affiliation(s)
- Martin Andersson
- Department of Chemistry, University of Florida, Gainesville, Florida 32611, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|