1
|
Liu Z, Meng X, Zhang Z, Liu R, Wang S, Lei JQ. Theoretical Study on Spectrum and Luminescence Mechanism of Cy5.5 and Cy7.5 Dye Based on Density Functional Theory (DFT). J Fluoresc 2023:10.1007/s10895-023-03525-4. [PMID: 38051402 DOI: 10.1007/s10895-023-03525-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 11/24/2023] [Indexed: 12/07/2023]
Abstract
Cy5.5 and 7.5 are the most commonly used NIR 2-region fluoresceins, which have good luminescence properties and important biomedical tracer applications. In this paper, their molecular non-covalent interactions, UV-Vis absorption spectra, main bond lengths, electrostatic potential distributions, frontier molecular orbitals (HOMO and LUMO) and energy gaps were calculated by density functional theory (DFT). We found that the differences in the luminescence properties and energy gaps of Cy5.5 and Cy7.5 molecules may be caused by the length of the conjugated chains between the two aromatic rings in the molecule. By calculating the relevant molecular characteristics, this paper can provide ideas and theoretical basis for the relevant modification and application, as well as the development of new fluorescent dyes.
Collapse
Affiliation(s)
- Zhao Liu
- First Hospital of Lanzhou University, Lanzhou University, 222 South Tianshui Road, Lanzhou, 730000, P. R. China
| | - Xv Meng
- First Hospital of Lanzhou University, Lanzhou University, 222 South Tianshui Road, Lanzhou, 730000, P. R. China
| | - Zhengze Zhang
- Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA
| | - Runzhang Liu
- First Hospital of Lanzhou University, Lanzhou University, 222 South Tianshui Road, Lanzhou, 730000, P. R. China
| | - Shutao Wang
- College of Chemistry and Chemical Engineering, Lanzhou University, 222 South Tianshui Road, Lanzhou, 730000, P. R. China
| | - Jun-Qiang Lei
- First Hospital of Lanzhou University, Lanzhou University, 222 South Tianshui Road, Lanzhou, 730000, P. R. China.
| |
Collapse
|
2
|
Jagtap J, Audi S, Razeghi-Kondelaji MH, Fish BL, Hansen C, Narayan J, Gao F, Sharma G, Parchur AK, Banerjee A, Bergom C, Medhora M, Joshi A. A rapid dynamic in vivo near-infrared fluorescence imaging assay to track lung vascular permeability after acute radiation injury. Am J Physiol Lung Cell Mol Physiol 2021; 320:L436-L450. [PMID: 33404364 DOI: 10.1152/ajplung.00066.2020] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
To develop a dynamic in vivo near-infrared (NIR) fluorescence imaging assay to quantify sequential changes in lung vascular permeability-surface area product (PS) in rodents. Dynamic NIR imaging methods for determining lung vascular permeability-surface area product were developed and tested on non-irradiated and 13 Gy irradiated rats with/without treatment with lisinopril, a radiation mitigator. A physiologically-based pharmacokinetic (PBPK) model of indocyanine green (ICG) pulmonary disposition was applied to in vivo imaging data and PS was estimated. In vivo results were validated by five accepted assays: ex vivo perfused lung imaging, endothelial filtration coefficient (Kf) measurement, pulmonary vascular resistance measurement, Evan's blue dye uptake, and histopathology. A PBPK model-derived measure of lung vascular permeability-surface area product increased from 2.60 ± 0.40 [CL: 2.42-2.78] mL/min in the non-irradiated group to 6.94 ± 8.25 [CL: 3.56-10.31] mL/min in 13 Gy group after 42 days. Lisinopril treatment lowered PS in the 13 Gy group to 4.76 ± 6.17 [CL: 2.12-7.40] mL/min. A much higher up to 5× change in PS values was observed in rats exhibiting severe radiation injury. Ex vivo Kf (mL/min/cm H2O/g dry lung weight), a measure of pulmonary vascular permeability, showed similar trends in lungs of irradiated rats (0.164 ± 0.081 [CL: 0.11-0.22]) as compared to non-irradiated controls (0.022 ± 0.003 [CL: 0.019-0.025]), with reduction to 0.070 ± 0.035 [CL: 0.045-0.096] for irradiated rats treated with lisinopril. Similar trends were observed for ex vivo pulmonary vascular resistance, Evan's blue uptake, and histopathology. Our results suggest that whole body dynamic NIR fluorescence imaging can replace current assays, which are all terminal. The imaging accurately tracks changes in PS and changes in lung interstitial transport in vivo in response to radiation injury.
Collapse
Affiliation(s)
- Jaidip Jagtap
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Said Audi
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin.,Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin
| | | | - Brian L Fish
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Christopher Hansen
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Jayashree Narayan
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Feng Gao
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Gayatri Sharma
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Abdul K Parchur
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Anjishnu Banerjee
- Division of Biostatistics, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Carmen Bergom
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin.,Department of Pharmacology and Toxicology, Medical College of Wisconsin, Milwaukee, Wisconsin.,Cancer Center, Medical College of Wisconsin, Milwaukee, Wisconsin.,Cardiovascular Center, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Meetha Medhora
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin.,Cardiovascular Center, Medical College of Wisconsin, Milwaukee, Wisconsin.,Department of Pulmonary Medicine, Medical College of Wisconsin, Milwaukee, Wisconsin
| | - Amit Joshi
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, Wisconsin.,Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin
| |
Collapse
|
3
|
Kanniyappan U, Wang B, Yang C, Ghassemi P, Litorja M, Suresh N, Wang Q, Chen Y, Pfefer TJ. Performance test methods for near-infrared fluorescence imaging. Med Phys 2020; 47:3389-3401. [PMID: 32304583 PMCID: PMC7496362 DOI: 10.1002/mp.14189] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/03/2020] [Accepted: 04/10/2020] [Indexed: 12/15/2022] Open
Abstract
PURPOSE Near-infrared fluorescence (NIRF) imaging using exogenous contrast has gained much attention as a technique for enhancing visualization of vasculature using untargeted agents, as well as for the detection and localization of cancer with targeted agents. In order to address the emerging need for standardization of NIRF imaging technologies, it is necessary to identify the best practices suitable for objective, quantitative testing of key image quality characteristics. Toward the development of a battery of test methods that are rigorous yet applicable to a wide variety of devices, we have evaluated techniques for phantom design, measurement, and calculation of specific performance metrics. METHODS Using a NIRF imaging system for indocyanine green imaging, providing excitation at 780 nm and detection above 830 nm, we explored methods to evaluate uniformity, field of view, spectral crosstalk, spatial resolution, depth of field, sensitivity, linearity, and penetration depth. These measurements were performed using fluorophore-doped multiwell plate and high turbidity planar phantoms, as well as a 3D-printed multichannel phantom and a USAF 1951 resolution target. RESULTS AND CONCLUSIONS Based on a wide range of approaches described in medical and fluorescence imaging literature, we have developed and demonstrated a cohesive battery of test methods for evaluation of fluorescence image quality in wide-field imagers. We also propose a number of key metrics that can facilitate direct, quantitative comparison of device performance. These methods have the potential to facilitate more uniform evaluation and inter-comparison of clinical and preclinical imaging systems than is typically achieved, with the long-term goal of establishing international standards for fluorescence image quality assessment.
Collapse
Affiliation(s)
- Udayakumar Kanniyappan
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.,Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, USA
| | - Bohan Wang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | - Charles Yang
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | - Pejhman Ghassemi
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, USA
| | - Maritoni Litorja
- National Institute of Standards and Technology, Gaithersburg, MD, USA
| | - Nitin Suresh
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA
| | - Quanzeng Wang
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, USA
| | - Yu Chen
- Fischell Department of Bioengineering, University of Maryland, College Park, MD, USA.,Department of Biomedical Engineering, University of Massachusetts Amherst, MA, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, Food and Drug Administration, Silver Spring, MD, USA
| |
Collapse
|
4
|
Hirano F, Yokoyama-Kokuryo W, Yamazaki H, Tsutsumino M, Sakai R, Satoh S, Kimura T, Tojo N, Kohsaka H, Harigai M. Comparison of fluorescence optical imaging, ultrasonography and clinical examination with magnetic resonance imaging as a reference in active rheumatoid arthritis patients. Immunol Med 2018; 41:75-81. [PMID: 30938268 DOI: 10.1080/13497413.2018.1481578] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND Fluorescence optical imaging with indocyanine-green enhancement (FOI) is a new imaging modality for the assessment of hand arthritis. The objective of this study was to compare performance profiles of clinical examination (CE), US and FOI using MRI as a reference in the same active rheumatoid arthritis (RA) patients. METHODS CE, US, FOI and MRI were performed on six subjects with active RA. Each sequence of FOI was divided into three phases based on indocyanine-green dynamics and the joints were graded semi-quantitatively. Sensitivities and specificities of CE, US and FOI were calculated using the RAMRIS synovitis score >0 as a reference in a total of 30 joints (the second to fifth metacarpophalangeal (MCP) joints and the wrist of the clinically dominant hand). RESULTS FOI showed sensitivities and specificities, respectively, of 85% and of 94% for Phase-1 and 69% and 94% for Phase-2. Sensitivities and specificities were 100% and 35% for CE (tender or swollen), 92% and 41% for gray scale US, and 77% and 100% for color-Doppler US. CONCLUSIONS The performance characteristics of FOI in detection of synovitis in patients with active RA are comparable to those of US and more specific than CE. FOI has a potential as an assessment modality of RA.
Collapse
Affiliation(s)
- Fumio Hirano
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Waka Yokoyama-Kokuryo
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Hayato Yamazaki
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Michi Tsutsumino
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Ryoko Sakai
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Shiro Satoh
- c Department of Diagnostic Imaging , Ochanomizu Surugadai Clinic , Tokyo , Japan
| | - Tomo Kimura
- c Department of Diagnostic Imaging , Ochanomizu Surugadai Clinic , Tokyo , Japan
| | - Naoko Tojo
- d Department of Clinical Laboratory , Medical Hospital, Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Hitoshi Kohsaka
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| | - Masayoshi Harigai
- a Department of Rheumatology , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan.,b Department of Pharmacovigilance , Tokyo Medical and Dental University (TMDU) , Tokyo , Japan
| |
Collapse
|
5
|
Jagtap J, Sharma G, Parchur AK, Gogineni V, Bergom C, White S, Flister MJ, Joshi A. Methods for detecting host genetic modifiers of tumor vascular function using dynamic near-infrared fluorescence imaging. BIOMEDICAL OPTICS EXPRESS 2018; 9:543-556. [PMID: 29552392 PMCID: PMC5854057 DOI: 10.1364/boe.9.000543] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 12/07/2017] [Accepted: 01/03/2018] [Indexed: 05/06/2023]
Abstract
Vascular supply is a critical component of the tumor microenvironment (TME) and is essential for tumor growth and metastasis, yet the endogenous genetic modifiers that impact vascular function in the TME are largely unknown. To identify the host TME modifiers of tumor vascular function, we combined a novel genetic mapping strategy [Consomic Xenograft Model] with near-infrared (NIR) fluorescence imaging and multiparametric analysis of pharmacokinetic modeling. To detect vascular flow, an intensified cooled camera based dynamic NIR imaging system with 785 nm laser diode based excitation was used to image the whole-body fluorescence emission of intravenously injected indocyanine green dye. Principal component analysis was used to extract the spatial segmentation information for the lungs, liver, and tumor regions-of-interest. Vascular function was then quantified by pK modeling of the imaging data, which revealed significantly altered tissue perfusion and vascular permeability that were caused by host genetic modifiers in the TME. Collectively, these data demonstrate that NIR fluorescent imaging can be used as a non-invasive means for characterizing host TME modifiers of vascular function that have been linked with tumor risk, progression, and response to therapy.
Collapse
Affiliation(s)
- Jaidip Jagtap
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - Gayatri Sharma
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - Abdul K. Parchur
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | | | - Carmen Bergom
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - Sarah White
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - Michael J. Flister
- Department of Physiology, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| | - Amit Joshi
- Department of Biomedical Engineering, Medical College of Wisconsin, Milwaukee, WI 53226, USA
- Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226, USA
| |
Collapse
|
6
|
Binzoni T, Sassaroli A, Torricelli A, Spinelli L, Farina A, Durduran T, Cavalieri S, Pifferi A, Martelli F. Depth sensitivity of frequency domain optical measurements in diffusive media. BIOMEDICAL OPTICS EXPRESS 2017; 8:2990-3004. [PMID: 28663921 PMCID: PMC5480444 DOI: 10.1364/boe.8.002990] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2017] [Revised: 04/13/2017] [Accepted: 04/18/2017] [Indexed: 05/03/2023]
Abstract
The depth sensitivity functions for AC amplitude, phase (PH) and DC intensity signals have been obtained in the frequency domain (where the source amplitude is modulated at radio-frequencies) by making use of analytical solutions of the photon diffusion equation in an infinite slab geometry. Furthermore, solutions for the relative contrast of AC, PH and DC signals when a totally absorbing plane is placed at a fixed depth of the slab have also been obtained. The solutions have been validated by comparisons with gold standard Monte Carlo simulations. The obtained results show that the AC signal, for modulation frequencies < 200 MHz, has a depth sensitivity with similar characteristics to that of the continuous-wave (CW) domain (source modulation frequency of zero). Thus, the depth probed by such a signal can be estimated by using the formula of penetration depth for the CW domain (Sci. Rep.6, 27057 (2016)). However, the PH signal has a different behavior compared to the CW domain, showing a larger depth sensitivity at shallow depths and a less steep relative contrast as a function of depth. These results mark a clear difference in term of depth sensitivity between AC and PH signals, and highlight the complexity of the estimation of the actual depth probed in tissue spectroscopy.
Collapse
Affiliation(s)
- Tiziano Binzoni
- Département de Neurosciences Fondamentales, University of Geneva, Switzerland
- Département de l'Imagerie et des Sciences de l'Information Médicale, University Hospital, Geneva, Switzerland
| | - Angelo Sassaroli
- Tufts University, Department of Biomedical Engineering, 4 Colby Street, Medford, MA 02155 USA
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Andrea Farina
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Turgut Durduran
- ICFO-Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Av. Carl Friedrich Gauss, 3, Castelldefels (Barcelona), 08860, Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA) (Barcelona, Spain)
| | - Stefano Cavalieri
- Università degli Studi di Firenze, Dipartimento di Fisica e Astronomia, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - Fabrizio Martelli
- Università degli Studi di Firenze, Dipartimento di Fisica e Astronomia, Via G. Sansone 1, 50019 Sesto Fiorentino, Firenze, Italy
| |
Collapse
|
7
|
Barnes TG, Penna M, Hompes R, Cunningham C. Fluorescence to highlight the urethra: a human cadaveric study. Tech Coloproctol 2017; 21:439-444. [PMID: 28560481 PMCID: PMC5495841 DOI: 10.1007/s10151-017-1615-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Accepted: 02/26/2017] [Indexed: 02/06/2023]
Abstract
Background Urethral injury is a complication feared by surgeons performing transanal TME (TaTME) or abdominoperineal excision (APE) procedures. Injury during TaTME occurs when the prostate is inadvertently mobilised or as a direct injury similar to the direct injury during the perineal dissection of APE procedures. We performed a proof of principle study to assess the feasibility of using indocyanine green (ICG) to fluoresce the urethra in human cadavers. Methods Indocyanine green at varying doses was mixed with Instillagel and infiltrated into the urethra of male human cadavers. The urethra was exposed through either a perineal incision or by mobilisation of the prostate during a TaTME dissection and fluorescence observed using a PINPOINT laparoscope (NOVADAQ). Brightness was assessed on the images using ImageJ (National Institute of Health).
Results Eight cadavers were included in the study. Fluorescence was visualised in the urethra in all eight cadavers. Minimal dissection was required to obtain fluorescence transperineally. In one cadaver, the urethra was demonstrated under fluorescence using a simulated TaTME with additional fluorescence also being observed in the prostate. There was no correlation between brightness and dosing. Conclusions This novel proof of principle study demonstrates a simple way in which the urethra may be easily identified preventing it from injury during surgery. Electronic supplementary material The online version of this article (doi:10.1007/s10151-017-1615-y) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- T G Barnes
- Department of Colorectal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK. .,Nuffield Department of Surgery, John Radcliffe Hospital, Headley Way, Headington, OX3 9DS, UK.
| | - M Penna
- Department of Colorectal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - R Hompes
- Department of Colorectal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - C Cunningham
- Department of Colorectal Surgery, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| |
Collapse
|
8
|
Near-Infrared Fluorescence-Enhanced Optical Tomography. BIOMED RESEARCH INTERNATIONAL 2016; 2016:5040814. [PMID: 27803924 PMCID: PMC5075630 DOI: 10.1155/2016/5040814] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2016] [Accepted: 08/25/2016] [Indexed: 11/18/2022]
Abstract
Fluorescence-enhanced optical imaging using near-infrared (NIR) light developed for in vivo molecular targeting and reporting of cancer provides promising opportunities for diagnostic imaging. The current state of the art of NIR fluorescence-enhanced optical tomography is reviewed in the context of the principle of fluorescence, the different measurement schemes employed, and the mathematical tools established to tomographically reconstruct the fluorescence optical properties in various tissue domains. Finally, we discuss the recent advances in forward modeling and distributed memory parallel computation to provide robust, accurate, and fast fluorescence-enhanced optical tomography.
Collapse
|
9
|
Lavazza M, Liu X, Wu C, Anuwong A, Kim HY, Liu R, Randolph GW, Inversini D, Boni L, Rausei S, Frattini F, Dionigi G. Indocyanine green-enhanced fluorescence for assessing parathyroid perfusion during thyroidectomy. Gland Surg 2016; 5:512-521. [PMID: 27867866 DOI: 10.21037/gs.2016.10.06] [Citation(s) in RCA: 48] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Identification of the parathyroid glands during thyroid surgery may prevent their inadvertent surgical removal and thus provide a better postoperative quality of life. Nevertheless, the most common "technique" for intraoperative evaluation of perfusion of parathyroid gland tissues during thyroid surgery is visual inspection of the physical condition of tissues, e.g., their color and bleeding edges. Another technique is measurement of intact parathyroid hormone. Recently, indocyanine green-enhanced fluorescence has been used in various surgical techniques, particularly laparoscopic surgery, to improve visualization and to provide detailed anatomical information. Fluorescent optical guidance helps surgeons to avoid inadvertent tissue injury while enhancing procedural efficiency. This technique has potential use for evaluating perfusion of the parathyroid gland in real-time intraoperative angiography.
Collapse
Affiliation(s)
- Matteo Lavazza
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| | - Xiaoli Liu
- Division of Thyroid Surgery, Jilin Provincial Key Laboratory of Surgical Translational Medicine, Japan Union Hospital of Jilin University, Changchun 130033, China
| | - Chewei Wu
- Department of Otolaryngology, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung City, Taiwan
| | - Angkoon Anuwong
- Department of Surgery, Police General Hospital, Faculty of Medicine, Siam University, Pathumwan, Bangkok, Thailand
| | - Hoon Yub Kim
- KUMC Thyroid Center Korea University, Anam Hospital, Seoul, Korea
| | - Renbin Liu
- The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou 510630, China
| | - Gregory W Randolph
- Division of Thyroid and Parathyroid Surgery, Department of Otolaryngology, Massachusetts Eye and Ear Infirmary and Harvard Medical School, Boston, Massachusetts, USA
| | - Davide Inversini
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| | - Luigi Boni
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| | - Stefano Rausei
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| | - Francesco Frattini
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| | - Gianlorenzo Dionigi
- 1st Division of General Surgery, Research Center for Endocrine Surgery, Department of Surgical Sciences and Human Morphology, University of Insubria (Varese-Como), via Guicciardini 9, 21100 Varese, Italy
| |
Collapse
|
10
|
Schnelldorfer T, Jenkins RL, Birkett DH, Georgakoudi I. From shadow to light: visualization of extrahepatic bile ducts using image-enhanced laparoscopy. Surg Innov 2014; 22:194-200. [PMID: 24786338 DOI: 10.1177/1553350614531661] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Correct recognition of the extrahepatic bile ducts is thought to be crucial to reduce the risk of bile duct injuries during various laparoscopic procedures. Image-enhanced laparoscopy techniques, utilizing various optical modalities other than white light, may help in detecting structures "hidden" underneath connective tissue. METHODS A systematic literature search was conducted of studies describing image-enhanced laparoscopy techniques for visualization of the extrahepatic bile ducts. RESULTS In all, 29 articles met inclusion criteria. They describe various techniques in the animal or human setting, including autofluorescence imaging, drug-enhanced fluorescence imaging, infrared thermography, and spectral imaging. This review describes these various techniques and their results. CONCLUSION Image-enhanced laparoscopy techniques for real-time visualization of extrahepatic bile ducts are still in its infancy. Out of the techniques currently described, indocyanine green-enhanced near-infrared fluorescence laparoscopy has the most mature results, but other techniques also appear promising. It can be expected that in the future, image-enhanced laparoscopy might become a routine adjunct to any white-light laparoscopic operation near the hepatic hilum.
Collapse
|
11
|
Daskalaki D, Fernandes E, Wang X, Bianco FM, Elli EF, Ayloo S, Masrur M, Milone L, Giulianotti PC. Indocyanine green (ICG) fluorescent cholangiography during robotic cholecystectomy: results of 184 consecutive cases in a single institution. Surg Innov 2014; 21:615-21. [PMID: 24616013 DOI: 10.1177/1553350614524839] [Citation(s) in RCA: 96] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND/AIM Laparoscopic cholecystectomy is currently the gold standard treatment for gallstone disease. Bile duct injury is a rare and severe complication of this procedure, with a reported incidence of 0.4% to 0.8% and is mostly a result of misperception and misinterpretation of the biliary anatomy. Robotic cholecystectomy has proven to be a safe and feasible approach. One of the latest innovations in minimally invasive technology is fluorescent imaging using indocyanine green (ICG). The aim of this study is to evaluate the efficacy of ICG and the Da Vinci Fluorescence Imaging Vision System in real-time visualization of the biliary anatomy. METHODS A total of 184 robotic cholecystectomies with ICG fluorescence cholangiography were performed between July 2011 and February 2013. All patients received a dose of 2.5 mg of ICG 45 minutes prior to the beginning of the surgical procedure. The procedures were multiport or single port depending on the case. RESULTS No conversions to open or laparoscopic surgery occurred in this series. The overall postoperative complication rate was 3.2%. No biliary injuries occurred. ICG fluorescence allowed visualization of at least 1 biliary structure in 99% of cases. The cystic duct, the common bile duct, and the common hepatic duct were successfully visualized with ICG in 97.8%, 96.1%, and 94% of cases, respectively. CONCLUSIONS ICG fluorescent cholangiography during robotic cholecystectomy is a safe and effective procedure that helps real-time visualization of the biliary tree anatomy.
Collapse
Affiliation(s)
- Despoina Daskalaki
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | - Eduardo Fernandes
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | - Xiaoying Wang
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | | | | | - Subashini Ayloo
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | - Mario Masrur
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | - Luca Milone
- University of Illinois Hospital and Health Sciences System, Chicago, IL, USA
| | | |
Collapse
|
12
|
Zhu B, Rasmussen JC, Sevick-Muraca EM. Non-invasive fluorescence imaging under ambient light conditions using a modulated ICCD and laser diode. BIOMEDICAL OPTICS EXPRESS 2014; 5:562-72. [PMID: 24575349 PMCID: PMC3920885 DOI: 10.1364/boe.5.000562] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2013] [Revised: 01/22/2014] [Accepted: 01/22/2014] [Indexed: 05/06/2023]
Abstract
One limitation of fluorescence molecular imaging that can limit clinical implementation and hamper small animal imaging is the inability to eliminate ambient light. Herein, we demonstrate the ability to conduct rapid non-invasive, far-red and near-infrared fluorescence imaging in living animals and a phantom under ambient light conditions using a modulated image intensified CCD (ICCD) and a laser diode operated in homodyne detection. By mapping AC amplitude from three planar images at varying phase delays, we show improvement in target-to-background ratios (TBR) and reasonable signal-to-noise ratios (SNR) over continuous wave measurements. The rapid approach can be used to accurately collect fluorescence in situations where ambient light cannot be spectrally conditioned or controlled, such as in the case of fluorescent molecular image-guided surgery.
Collapse
|
13
|
Werner SG, Langer HE, Schott P, Bahner M, Schwenke C, Lind-Albrecht G, Spiecker F, Kurtz B, Burmester GR, Backhaus M. Indocyanine Green-Enhanced Fluorescence Optical Imaging in Patients With Early and Very Early Arthritis: A Comparative Study With Magnetic Resonance Imaging. ACTA ACUST UNITED AC 2013; 65:3036-44. [DOI: 10.1002/art.38175] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Accepted: 08/22/2013] [Indexed: 01/18/2023]
Affiliation(s)
- Stephanie G. Werner
- Charité University Medicine Berlin; Berlin Germany
- RHIO Center Dusseldorf and RHIO Research Institute; Dusseldorf Germany
| | | | - Peter Schott
- Evangelisches Krankenhaus Dusseldorf; Dusseldorf Germany
| | | | | | | | | | - Bernward Kurtz
- Evangelisches Krankenhaus Dusseldorf; Dusseldorf Germany
| | | | | |
Collapse
|
14
|
Real-time near-infrared (NIR) fluorescent cholangiography in single-site robotic cholecystectomy (SSRC): a single-institutional prospective study. Surg Endosc 2012; 27:2156-62. [PMID: 23271272 DOI: 10.1007/s00464-012-2733-2] [Citation(s) in RCA: 105] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Accepted: 12/01/2012] [Indexed: 02/07/2023]
Abstract
BACKGROUND Bile duct injury is a rare but serious complication of laparoscopic cholecystectomy and the primary cause is misinterpretation of biliary anatomy. This may occur more frequently with a single-incision approach due to difficulties in exposing and visualizing the triangle of Calot. Intraoperative cholangiography was proposed to overcome this problem, but due to multiple issues, it is not used routinely. Indocyanine green (ICG) near-infrared (NIR) fluorescent cholangiography is non invasive and provides real-time biliary images during surgery, which may improve the safety of single-incision cholecystectomy. This study aims to evaluate the efficacy and safety of this technique during single-site robotic cholecystectomy (SSRC). METHODS Patients presenting with symptomatic biliary gallstones without suspicion of common bile duct stones underwent SSRC with ICG-NIR fluorescent cholangiography using the da Vinci Fluorescence Imaging Vision System. During patient preparation, 2.5 mg of ICG was injected intravenously. During surgery, the biliary anatomy was imaged in real time, which guided dissection of Calot's triangle. Perioperative outcomes included biliary tree visualizations, operative time, conversion and complications rates, and length of hospital stay. RESULTS There were 45 cases between July 2011 and January 2012. All procedures were completed successfully; there were no conversions and at least one structure was visualized in each patient. The rates of visualization were 93 % for the cystic duct, 88 % for the common hepatic duct, and 91 % for the common bile duct prior to Calot's dissection; after Calot's dissection, the rates were 97 % for all three ducts. Mean hospital stay was 1.1 days and there were no bile duct injuries or any other major complications. CONCLUSION Real-time high-resolution fluorescent imaging to identify the biliary tree anatomy during SSRC using the da Vinci Fluorescence Imaging Vision System was safe and effective.
Collapse
|
15
|
Zhu B, Tan IC, Rasmussen JC, Sevick-Muraca EM. Validating the Sensitivity and Performance of Near-Infrared Fluorescence Imaging and Tomography Devices Using a Novel Solid Phantom and Measurement Approach. Technol Cancer Res Treat 2012; 11:95-104. [DOI: 10.7785/tcrt.2012.500238] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
With the aid of indocyanine green (ICG), lymphatic architecture and function in both mice and humans has been successfully imaged non-invasively using near-infrared (NIR) fluorescence imaging devices. Maximal measurement sensitivity of NIR fluorescence imaging devices is needed for “first-in-humans” molecularly targeting NIR fluorescence agents that are brighter than non-specific ICG. In this study, we developed a solid phantom and measurement approach for the quantification of excitation light leakage and measurement sensitivity of NIR fluorescence imaging devices. The constructed solid phantom, consisting of quantum dots impregnated onto specularly reflective surface, shows long-term stability and can be used as a traceable fluorescence standard. With the constructed solid phantom, the intensified CCD (ICCD)-based device demonstrated more than 300% higher measurement sensitivity compared to the Electron Multiplying CCD (EMCCD) based device when integration time was maintained less than 1.0 s.
Collapse
Affiliation(s)
- B. Zhu
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, Houston, TX 77030
| | - I.-C. Tan
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, Houston, TX 77030
| | - J. C. Rasmussen
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, Houston, TX 77030
| | - E. M. Sevick-Muraca
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, Houston, TX 77030
| |
Collapse
|
16
|
Buddingh KT, Nieuwenhuijs VB, van Buuren L, Hulscher JBF, de Jong JS, van Dam GM. Intraoperative assessment of biliary anatomy for prevention of bile duct injury: a review of current and future patient safety interventions. Surg Endosc 2011; 25:2449-61. [PMID: 21487883 PMCID: PMC3142332 DOI: 10.1007/s00464-011-1639-8] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2010] [Accepted: 01/28/2011] [Indexed: 12/20/2022]
Abstract
Background Bile duct injury (BDI) is a dreaded complication of cholecystectomy, often caused by misinterpretation of biliary anatomy. To prevent BDI, techniques have been developed for intraoperative assessment of bile duct anatomy. This article reviews the evidence for the different techniques and discusses their strengths and weaknesses in terms of efficacy, ease, and cost-effectiveness. Method PubMed was searched from January 1980 through December 2009 for articles concerning bile duct visualization techniques for prevention of BDI during laparoscopic cholecystectomy. Results Nine techniques were identified. The critical-view-of-safety approach, indirectly establishing biliary anatomy, is accepted by most guidelines and commentaries as the surgical technique of choice to minimize BDI risk. Intraoperative cholangiography is associated with lower BDI risk (OR 0.67, CI 0.61–0.75). However, it incurs extra costs, prolongs the operative procedure, and may be experienced as cumbersome. An established reliable alternative is laparoscopic ultrasound, but its longer learning curve limits widespread implementation. Easier to perform are cholecystocholangiography and dye cholangiography, but these yield poor-quality images. Light cholangiography, requiring retrograde insertion of an optical fiber into the common bile duct, is too unwieldy for routine use. Experimental techniques are passive infrared cholangiography, hyperspectral cholangiography, and near-infrared fluorescence cholangiography. The latter two are performed noninvasively and provide real-time images. Quantitative data in patients are necessary to further evaluate these techniques. Conclusions The critical-view-of-safety approach should be used during laparoscopic cholecystectomy. Intraoperative cholangiography or laparoscopic ultrasound is recommended to be performed routinely. Hyperspectral cholangiography and near-infrared fluorescence cholangiography are promising novel techniques to prevent BDI and thus increase patient safety.
Collapse
Affiliation(s)
- K Tim Buddingh
- Department of Surgery, University Medical Center Groningen, Groningen, the Netherlands.
| | | | | | | | | | | |
Collapse
|
17
|
Larush L, Magdassi S. Formation of near-infrared fluorescent nanoparticles for medical imaging. Nanomedicine (Lond) 2011; 6:233-40. [DOI: 10.2217/nnm.11.5] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aims: Indocyanine green (ICG) is a US FDA-approved near-infrared fluorescent, water-soluble dye used for diagnostics in vitro and in vivo. The aim of this study was to develop insoluble nanoparticles based on a cationic polymer, ICG and a targeting molecule. The particles are intended for oral administration in the colon, having fluorescence in near-infrared, thus enabling remote detection. Materials & methods: An aqueous dispersion of particles formed from Eudragit-RS by simple precipitation method possessing a mean size of approximately 100 nm and zeta potential of +16 mV was produced. Results: These particles are capable of binding both ICG and fluorescein isothiocyanate–IgG via noncovalent interactions. These composite particles retain the emission characteristics of the fluorescent precursors and also exhibit potential specific recognition ability. The particles were stable in intestinal fluid and are composed only of materials that are FDA approved. Conclusion: The nanoparticles may be suitable for in vivo imaging and therapy by oral delivery systems.
Collapse
Affiliation(s)
- Liraz Larush
- Casali Institute of Applied Chemistry, Institute of Chemistry, The Hebrew University of Jerusalem, Jerusalem 91904, Israel
| | | |
Collapse
|
18
|
Zhu B, Rasmussen JC, Lu Y, Sevick-Muraca EM. Reduction of excitation light leakage to improve near-infrared fluorescence imaging for tissue surface and deep tissue imaging. Med Phys 2011; 37:5961-70. [PMID: 21158309 DOI: 10.1118/1.3497153] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
PURPOSE Fluorescence-enhanced optical imaging using near-infrared (NIR) light developed for in vivo molecular targeting and reporting of various diseases provides promising opportunities for diagnostic imaging. However, the measurement sensitivity of NIR fluorescence (NIRF) optical imaging systems is limited by the leakage of the strong backscattered excitation light through rejection filters. In this article, the authors present a systematic method for improving sensitivity and validating the NIRF optical imager currently used for clinical imaging of human lymphatic function. METHODS The proposed systemic method consists of an appropriate filter combination and a collimation optics adapted to an NIRF optical imager. The spectral contributions were first assessed due to the excitation light backscattered from the tissue and from non-normal-incidence of the excitation light on the optical filters used in the authors' NIRF clinical imaging system. Then two tests were conducted to assess the system with and without the components of appropriate filters combination and collimation optics using: (1) a phantom to evaluate excitation light leakage as a function of target depth and (2) deployment in an actual human study. RESULTS The phantom studies demonstrate as much as two to three orders of magnitude reduction in the transmission ratio, indicating that the excitation light leakage can be reduced upon using the appropriate filter combination and collimation optics while an in vivo investigatory human study confirms improved imaging. CONCLUSIONS The method for reducing the excitation light leakage is presented for validating collected signals for fluorescence imaging.
Collapse
Affiliation(s)
- Banghe Zhu
- Center of Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, Houston, Texas 77030, USA
| | | | | | | |
Collapse
|
19
|
Marshall MV, Rasmussen JC, Tan IC, Aldrich MB, Adams KE, Wang X, Fife CE, Maus EA, Smith LA, Sevick-Muraca EM. Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update. ACTA ACUST UNITED AC 2010; 2:12-25. [PMID: 22924087 DOI: 10.2174/1876504101002010012] [Citation(s) in RCA: 162] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Near-infrared (NIR) fluorescence imaging clinical studies have been reported in the literature with six different devices that employ various doses of indocyanine green (ICG) as a non-specific contrast agent. To date, clinical applications range from (i) angiography, intraoperative assessment of vessel patency, and tumor/metastasis delineation following intravenous administration of ICG, and (ii) imaging lymphatic architecture and function following subcutaneous and intradermal ICG administration. In the latter case, NIR fluorescence imaging may enable new discoveries associated with lymphatic function due to (i) a unique niche that is not met by any other conventional imaging technology and (ii) its exquisite sensitivity enabling high spatial and temporal resolution. Herein, we (i) review the basics of clinical NIR fluorescence imaging, (ii) survey the literature on clinical application of investigational devices using ICG fluorescent contrast, (iii) provide an update of non-invasive dynamic lymphatic imaging conducted with our FDPM device, and finally, (iv) comment on the future NIR fluorescence imaging for non-invasive and intraoperative use given recent demonstrations showing capabilities for imaging following microdose administration of contrast agent.
Collapse
Affiliation(s)
- Milton V Marshall
- Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center, Houston, Texas 77030, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Erickson SJ, Godavarty A. Hand-held based near-infrared optical imaging devices: A review. Med Eng Phys 2009; 31:495-509. [DOI: 10.1016/j.medengphy.2008.10.004] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2008] [Revised: 07/12/2008] [Accepted: 10/15/2008] [Indexed: 11/15/2022]
|
21
|
Sevick-Muraca EM, Rasmussen JC. Molecular imaging with optics: primer and case for near-infrared fluorescence techniques in personalized medicine. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:041303. [PMID: 19021311 PMCID: PMC2915929 DOI: 10.1117/1.2953185] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
We compare and contrast the development of optical molecular imaging techniques with nuclear medicine with a didactic emphasis for initiating readers into the field of molecular imaging. The nuclear imaging techniques of gamma scintigraphy, single-photon emission computed tomography, and positron emission tomography are first briefly reviewed. The molecular optical imaging techniques of bioluminescence and fluorescence using gene reporter/probes and gene reporters are described prior to introducing the governing factors of autofluorescence and excitation light leakage. The use of dual-labeled, near-infrared excitable and radio-labeled agents are described with comparative measurements between planar fluorescence and nuclear molecular imaging. The concept of time-independent and -dependent measurements is described with emphasis on integrating time-dependent measurements made in the frequency domain for 3-D tomography. Finally, we comment on the challenges and progress for translating near-infrared (NIR) molecular imaging agents for personalized medicine.
Collapse
Affiliation(s)
- Eva M Sevick-Muraca
- Baylor College of Medicine, Department of Radiology, Division of Molecular Imaging, Houston, Texas 77030, USA.
| | | |
Collapse
|
22
|
Valentini G, D'Andrea C, Ferrari R, Pifferi A, Cubeddu R, Martinelli M, Natoli C, Ubezio P, Giavazzi R. In vivo measurement of vascular modulation in experimental tumors using a fluorescent contrast agent. Photochem Photobiol 2008; 84:1249-56. [PMID: 18422875 DOI: 10.1111/j.1751-1097.2008.00352.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
We compared the effectiveness of three optical techniques based on fluorescence imaging and spectroscopy with indocyanine green (ICG) contrast agent to evaluate in vivo the disruption of the active vasculature induced by a vascular targeting agent. The blood perfusion of the MDA-MB-435 tumor model transplanted in nude mice was estimated from the signal of the contrast agent measured immediately after its systemic injection in mice. Optical measurements were performed using a fluorescence imaging setup and a fiber-based time correlated single photon counting (TCSPC) apparatus. This latter apparatus was used to measure the tumor fluorescence in transmittance geometry and the change in the basal optical absorption induced by the contrast agent, thus providing an alternative estimation of the blood content in the tumor. Mice were divided into four groups. Three groups were treated with different doses of the vascular disrupting agent ZD6126, the fourth group (control group) received the drug vehicle only. Optical measurements were carried out 3 h after pharmacologic treatment. After 24 h, mice were killed, tumors were excised and the extent of necrosis was evaluated with standard histologic analysis. On fluorescence imaging ICG emission from tumors of mice treated with ZD6126 significantly was lower compared with the emission from control mice. The histologic sections also showed a significantly higher amount of necrosis in tumors of treated mice. Both these findings, which correlate with each other, indicate an effective vascular shutdown induced by the drug. However, ICG fluorescence measured with the TCSPC apparatus in transmittance geometry and the estimate of the change in optical absorption did not allow a statistically significant differentiation between treated and control groups.
Collapse
Affiliation(s)
- Gianluca Valentini
- IIT, ULTRAS-CNR-INFM and IFN-CNR, Dipartimento di Fisica, Politecnico di Milano, Milan, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Effets de la fluorescence résiduelle dans les tissus biologiques sur les signaux de fluorescence résolus temporellement par la méthode des éléments finis. Ing Rech Biomed 2008. [DOI: 10.1016/j.rbmret.2007.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
24
|
Keren S, Gheysens O, Levin CS, Gambhir SS. A comparison between a time domain and continuous wave small animal optical imaging system. IEEE TRANSACTIONS ON MEDICAL IMAGING 2008; 27:58-63. [PMID: 18270062 PMCID: PMC4143158 DOI: 10.1109/tmi.2007.902800] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
We present a phantom study to evaluate the performance of the eXplore Optix (Advanced Research Technologies-GE Healthcare), the first commercially available time-domain tomography system for small animal fluorescence imaging, and compare its capabilities with the widely used IVIS 200 (Xenogen Corporation-Caliper) continuous wave planar imaging system. The eXplore Optix, based on point-wise illumination and collection scheme, is found to be a log order more sensitive with significantly higher detection depth and spatial resolution as compared with the wide-area illumination IVIS 200 under the conditions tested. A time-resolved detection system allows the eXplore Optix to measure the arrival time distribution of fluorescence photons. This enables fluorescence lifetime measurement, absorption mapping, and estimation of fluorescent inclusion depth, which in turn is used by a reconstruction algorithm to calculate the volumetric distribution of the fluorophore concentration. An increased acquisition time and lack of ability to image multiple animals simultaneously are the main drawbacks of the eXplore Optix as compared with the IVIS 200.
Collapse
Affiliation(s)
- Shay Keren
- Molecular Imaging Program at Stanford (MIPS), Radiology Department, Stanford University, Stanford, CA 94305 USA
| | - Olivier Gheysens
- Molecular Imaging Program at Stanford (MIPS), Radiology Department, Stanford University, Stanford, CA 94305 USA
| | - Craig S. Levin
- Molecular Imaging Program at Stanford (MIPS), Radiology Department, Stanford University, Stanford, CA 94305 USA
| | | |
Collapse
|
25
|
Norman RS, Stone JW, Gole A, Murphy CJ, Sabo-Attwood TL. Targeted photothermal lysis of the pathogenic bacteria, Pseudomonas aeruginosa, with gold nanorods. NANO LETTERS 2008; 8:302-6. [PMID: 18062714 DOI: 10.1021/nl0727056] [Citation(s) in RCA: 313] [Impact Index Per Article: 18.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Increases in the prevalence of antibiotic resistant bacteria require new approaches for the treatment of infectious bacterial pathogens. It is now clear that a nanotechnology-driven approach using nanoparticles to selectively target and destroy pathogenic bacteria can be successfully implemented. We have explored this approach by using gold nanorods that have been covalently linked to primary antibodies to selectively destroy the pathogenic Gram-negative bacterium, Pseudomonas aeruginosa. We find that, following nanorod attachment to the bacterial cell surface, exposure to near-infrared radiation results in a significant reduction in bacterial cell viability.
Collapse
Affiliation(s)
- R Sean Norman
- Department of Environmental Health Sciences, Arnold School of Public Health, University of South Carolina, Columbia, South Carolina 29208, USA
| | | | | | | | | |
Collapse
|
26
|
Lin Y, Gao H, Nalcioglu O, Gulsen G. Fluorescence diffuse optical tomography with functional and anatomicala prioriinformation: feasibility study. Phys Med Biol 2007; 52:5569-85. [PMID: 17804882 DOI: 10.1088/0031-9155/52/18/007] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Fluorescence diffuse optical tomography (FT) is an emerging molecular imaging technique that can spatially resolve both fluorophore concentration and lifetime parameters. In this study, we investigate the performance of a frequency-domain FT system for small inclusions that are embedded in a heterogeneous background. The results demonstrate that functional and structural a priori information is crucial to be able to recover both parameters with high accuracy. The functional a priori information is defined by the absorption and scattering maps at both excitation and emission wavelengths. Similarly, the boundaries of the small inclusion and different regions in the background are utilized as the structural a priori information. Without a priori information, the fluorophore concentration of a 5 mm inclusion in a 40 mm medium is recovered with 50% error, while the lifetime cannot be recovered at all. On the other hand, when both functional and structural information are available, the true lifetime can be recovered and the fluorophore concentration can be estimated only with 5% error. This study shows that a hybrid system that can acquire diffuse optical absorption tomography (DOT), FT and anatomical images in the same setting is essential to be able to recover the fluorophore concentration and lifetime accurately in vivo.
Collapse
Affiliation(s)
- Y Lin
- Tu and Yuen Center for Functional Onco Imaging, University of California, Irvine, CA 92617, USA
| | | | | | | |
Collapse
|
27
|
Kervella M, Humeau A, L'Huillier JP. Effects of residual fluorescence on time-resolved signals simulated with the finite element method in biological tissues. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2007; 2007:5976-5979. [PMID: 18003375 DOI: 10.1109/iembs.2007.4353709] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A computational model based on finite element method is derived to examine how the simulated time-dependent signals are related to the presence of residual fluorescence in biological media surrounding a fluorescent object. We apply a subtraction technique on recorded data when imperfect uptake of fluorescing agent into the tumor is considered. We show the limits of the subtracting method for low target: background fluorescent absorption contrast by extracting the time to reach the half maximum and analyzing the maximum of the time-resolved signals versus target depth.
Collapse
Affiliation(s)
- Marine Kervella
- Groupe ISAIP-ESAIP, 18 rue du 8 mai 1945, BP 80022, 49180 Saint Barthélémy d'Anjou cedex, France.
| | | | | |
Collapse
|
28
|
Hwang K, Pan T, Joshi A, Rasmussen JC, Bangerth W, Sevick-Muraca EM. Influence of excitation light rejection on forward model mismatch in optical tomography. Phys Med Biol 2006; 51:5889-902. [PMID: 17068371 DOI: 10.1088/0031-9155/51/22/011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Fluorescence enhanced tomography for molecular imaging requires low background for detection and accurate image reconstruction. In this contribution, we show that excitation light leakage is responsible for elevated background and can be minimized with the use of gradient index (GRIN) lenses when using fibre optics to collect propagated fluorescence light from tissue or other biological media. We show that the model mismatch between frequency-domain photon migration (FDPM) measurements and the diffusion approximation prediction is decreased when GRIN lenses are placed prior to the interference filters to provide efficient excitation light rejection. Furthermore, model mismatch is correlated to the degree of excitation light leakage. This work demonstrates the importance of proper light filtering when designing fluorescence optical imaging and tomography.
Collapse
Affiliation(s)
- K Hwang
- Department of Radiology, Baylor College of Medicine, Houston, TX 77843, USA
| | | | | | | | | | | |
Collapse
|
29
|
Joshi A, Bangerth W, Hwang K, Rasmussen JC, Sevick-Muraca EM. Fully adaptive FEM based fluorescence optical tomography from time-dependent measurements with area illumination and detection. Med Phys 2006; 33:1299-310. [PMID: 16752565 DOI: 10.1118/1.2190330] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
Using an area-illumination and area-detection scheme, we acquire fluorescence frequency domain measurements from a tissue phantom with an embedded fluorescent target and obtain tomographic reconstructions of the interior fluorescence absorption map with an adaptive finite element based scheme. The tissue phantom consisted of a clear acrylic cubic box (512 ml) filled with 1% Liposyn solution, while the fluorescent targets were 5 mm diameter glass bulbs filled with 1 microM Indocyanine Green dye solution in 1% Liposyn. Frequency domain area illumination and detection employed a planar excitation source using an expanded intensity modulated (100 MHz) 785 nm diode laser light and a gain modulated image intensified charge coupled device camera, respectively. The excitation pattern was characterized by isolating the singly scattered component with cross polarizers and was input into a dual adaptive finite element-based scheme for three dimensional reconstructions of fluorescent targets embedded beneath the phantom surface. Adaptive mesh refinement techniques allowed efficient simulation of the incident excitation light and the reconstruction of fluorescent targets buried at the depths of 1 and 2 cm. The results demonstrate the first clinically relevant noncontact fluorescence tomography with adaptive finite element methods.
Collapse
Affiliation(s)
- Amit Joshi
- Division of Molecular Imaging, Department of Radiology, Baylor College of Medicine, Houston, Texas 77030, USA.
| | | | | | | | | |
Collapse
|
30
|
Dinish US, Fu CY, Chao ZX, Seah LK, Murukeshan VM, Ng BK. Subnanosecond-resolution phase-resolved fluorescence imaging technique for biomedical applications. APPLIED OPTICS 2006; 45:5020-6. [PMID: 16807613 DOI: 10.1364/ao.45.005020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Characterization of fluorescence emissions from cells often leads to conclusive results in the early detection of cellular abnormalities. Cellular abnormalities can be characterized by their difference in the fluorescence lifetime, which may be less than nanoseconds. A sensitive frequency domain technique, also called a phase-resolved fluorescence imaging technique, is proposed in which fluorescence emissions at the same wavelengths can more effectively be separated with subnanosecond resolution in their lifetime difference. The system configuration is optimized by incorporating even-step phase shifting in the homodyne-assisted signal-processing concept along with the phase-resolved fluorescence technique to eliminate the dc offsets of emission. Experiments are carried out with simulated samples composed of two fluorescence emissions of the same wavelength but with different lifetime values. Suppression of either of the fluorescence emissions by selective imaging of the other validates the superiority of the proposed technique. Hence, this technique can potentially be applied in the early detection of cellular abnormalities.
Collapse
Affiliation(s)
- U S Dinish
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, Nanyang Avenue, Singapore 639798.
| | | | | | | | | | | |
Collapse
|
31
|
Roy R, Godavarty A, Sevick-Muraca EM. Fluorescence-enhanced optical tomography of a large tissue phantom using point illumination geometries. JOURNAL OF BIOMEDICAL OPTICS 2006; 11:044007. [PMID: 16965164 DOI: 10.1117/1.2338807] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We demonstrate fluorescence-enhanced optical imaging of single and multiple fluorescent targets within a large (approximately 1081 cm3) phantom using frequency-domain photon migration measurements of fluorescence collected at individual points in response to illumination of excitation light at individual points on the boundary. The tissue phantom was filled with a 1% lipid solution with and without 0.01 microM Indocyanine Green (ICG) and targets consisted of vials filled with the 1% lipid containing 1-2.5 microM ICG. Measurements were acquired using a modulated intensified CCD imaging system under different experimental conditions. For 3-D image reconstruction, the gradient-based penalty modified barrier function (PMBF) method with simple bounds constrained truncated Newton with trust region method (CONTN) was used. Targets of 0.5, 0.6, and 1.0 cm3 at depths of 1.4-2.8 cm from the phantom surface were tomographically reconstructed. This work demonstrates the practicality of fluorescence-enhanced tomography in clinically relevant volumes.
Collapse
Affiliation(s)
- Ranadhir Roy
- Baylor College of Medicine, Photon Migration Laboratory, Houston, Texas 77030, USA.
| | | | | |
Collapse
|
32
|
Houston JP, Ke S, Wang W, Li C, Sevick-Muraca EM. Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:054010. [PMID: 16292970 DOI: 10.1117/1.2114748] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melanoma in xenografts. Twenty-four hours after administration of the dual-labeled peptide at a dose equivalent to 90 microCi of (111)In and 5 nmol of near-infrared (NIR) dye, whole-body gamma scintigraphy and cw imaging was conducted. Image acquisition time was 15 min for the gamma scintigraphy images and 800 ms for the optical images acquired using an NIR sensitive intensified charge-coupled device. The results show that while the target-to-background ratio (TBR) of nuclear and optical imaging were similar for surface regions of interest and consistent with the origin of gamma and NIR radiation from a common targeted peptide, the signal-to-noise ratio (SNR) was significantly higher for optical than nuclear imaging. Furthermore, an analysis of SNR versus contrast showed greater sensitivity of optical over nuclear imaging for the subcutaneous tumor targets. While tomographic reconstructions are necessary to probe TBR, SNR, and contrast for interior tissues, this work demonstrates for the first time the direct comparison of molecular optical and planar nuclear imaging for surface and subsurface cancers.
Collapse
Affiliation(s)
- Jessica P Houston
- Texas A&M University, Photon Migration Laboratory, College Station, Texas 77842-3012, USA
| | | | | | | | | |
Collapse
|
33
|
Hwang K, Houston JP, Rasmussen JC, Joshi A, Ke S, Li C, Sevick-Muraca EM. Improved Excitation Light Rejection Enhances Small-Animal Fluorescent Optical Imaging. Mol Imaging 2005; 4:194-204. [PMID: 16194451 DOI: 10.1162/15353500200505142] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/29/2005] [Indexed: 11/04/2022] Open
Abstract
Small-animal fluorescence-enhanced imaging involves the detection of weak fluorescent signals emanating from nanomolar to picomolar concentrations of exogenous or endogenously produced fluorophore concurrent with the rejection of an overwhelmingly large component of backscattered excitation light. The elimination of the back-reflected excitation light of the collected signal remains a major and often unrecognized challenge for further reducing the noise floor and increasing sensitivity of small-animal fluorescence imaging. Herein, we show that the combination of three-cavity interference and holographic super notch filters with appropriate imaging lenses to collimate light improves rejection of excitation light, enabling more accurate imaging. To assess excitation leakage, the “out-of-band ( S(Λ x))” to “in-band ( S(Λ m)– S(Λ x))” signal ratio from phantom studies and the target-to-background ratio (TBR) from in vivo animal imaging was acquired with and without collimating optics. The addition of collimating optics resulted in a 51% to 75% reduction in the ratio of ( S(Λ x))/( S(Λ m)– S(Λ x)) for the phantom studies and an improvement of TBR from 11% to 31% and of signal-to-noise ratio from 11% to 142% for an integrin-targeting conjugate in human glioma xenografts.
Collapse
|
34
|
Godavarty A, Eppstein MJ, Zhang C, Sevick-Muraca EM. Detection of single and multiple targets in tissue phantoms with fluorescence-enhanced optical imaging: feasibility study. Radiology 2005; 235:148-54. [PMID: 15798170 DOI: 10.1148/radiol.2343031725] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate the feasibility of reconstructing single and multiple targets by using fluorescence-enhanced tomography of a breast tissue phantom. MATERIALS AND METHODS Frequency-domain fluorescence measurements were performed in cup-shaped tissue phantoms of clinically relevant size (diameter, 10 cm) in which single or multiple 0.5-1.0-cm(3) targets that contained micromolar concentrations of indocyanine green with 1:0 and 100:1 target-to-background (T:B) contrast ratios had been embedded. Rapid acquisition of time-dependent fluorescent light measurements was performed at the phantom surface in response to point illumination of excitation light by using a gain-modulated intensified charge-coupled device detection system. Boundary surface measurements were used to tomographically reconstruct the interior targets located with various experimental conditions. RESULTS Single 1.0-cm(3) targets located between 1.43 and 2.82 cm deep from the phantom surface at a T:B contrast ratio of 100:1 and three approximately 0.55-cm(3) targets located about 1.30 cm deep at a T:B contrast ratio of 1:0 were reconstructed with minimal or no artifacts by using boundary surface fluorescence measurements and an approximate extended Kalman filter algorithm. CONCLUSION It is feasible to detect single or multiple fluorescent targets in tissue phantoms of clinically relevant size by using fluorescence-enhanced optical tomography.
Collapse
Affiliation(s)
- Anuradha Godavarty
- Photon Migration Laboratories, Texas A&M University, PO Box 30012, College Station, TX 77842-3012, USA
| | | | | | | |
Collapse
|
35
|
Perlitz C, Licha K, Scholle FD, Ebert B, Bahner M, Hauff P, Moesta KT, Schirner M. Comparison of Two Tricarbocyanine-Based Dyes for Fluorescence Optical Imaging. J Fluoresc 2005; 15:443-54. [PMID: 15986163 DOI: 10.1007/s10895-005-2636-x] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2005] [Accepted: 12/22/2004] [Indexed: 11/29/2022]
Abstract
Optical technologies are evolving in many biomedical areas including the biomedical imaging disciplines. Regarding the absorption properties of physiological molecules in living tissue, the optical window ranging from 700 to 900 nm allows to use fluorescent dyes for novel diagnostic solutions. Here we investigate the potential of two different carbocyanine-based dyes fluorescent in the near infrared as contrast agents for in vivo imaging of subcutaneously grown tumours in laboratory animals. The primary aim was to modify the physicochemical properties of the previously synthesized dye SIDAG to investigate the effect on the in vivo imaging properties.
Collapse
Affiliation(s)
- Christin Perlitz
- Optical Imaging and New Modalities Research, Research Laboratories, Schering AG, Müllerstrasse, 13342 Berlin, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
36
|
Roy R, Thompson AB, Godavarty A, Sevick-Muraca EM. Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry. IEEE TRANSACTIONS ON MEDICAL IMAGING 2005; 24:137-154. [PMID: 15707240 DOI: 10.1109/tmi.2004.839359] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified charge-coupled device (ICCD) camera. The image reconstruction problem was formulated as a nonlinear least-squares-type simple bounds constrained optimization problem based upon the penalty/modified barrier function (PMBF) method and the coupled diffusion equations. The simple bounds constraints are included in the objective function of the PMBF method and the gradient-based truncated Newton method with trust region is used to minimize the function for the large-scale problem (39919 unknowns, 2973 measurements). Three-dimensional (3-D) images of fluorescence absorption coefficients were reconstructed using the algorithm from experimental reflectance measurements under conditions of perfect and imperfect distribution of fluorophore within a single target. To our knowledge, this is the first time that targets have been reconstructed in three-dimensions from reflectance measurements with a clinically relevant phantom.
Collapse
MESH Headings
- Algorithms
- Animals
- Artificial Intelligence
- Connective Tissue/ultrastructure
- Humans
- Image Enhancement/methods
- Image Interpretation, Computer-Assisted/methods
- Microscopy, Fluorescence/instrumentation
- Microscopy, Fluorescence/methods
- Numerical Analysis, Computer-Assisted
- Phantoms, Imaging
- Reproducibility of Results
- Sensitivity and Specificity
- Signal Processing, Computer-Assisted
- Spectrophotometry, Infrared/instrumentation
- Spectrophotometry, Infrared/methods
- Tomography, Optical/instrumentation
- Tomography, Optical/methods
Collapse
Affiliation(s)
- R Roy
- The Photon Migration Laboratories, Texas A&M University, College Station, TX 77843-3573, USA.
| | | | | | | |
Collapse
|
37
|
Abstract
Diffuse optical tomography is emerging as a viable new biomedical imaging modality. Using visible and near-infrared light this technique can probe the absorption and scattering properties of biological tissues. The main applications are currently in brain, breast, limb and joint imaging; however, optical tomographic imaging of small animals is attracting increasing attention. This interest is fuelled by recent advances in the transgenic manipulation of small animals that has led to many models of human disease. In addition, an ever increasing number of optically reactive biochemical markers has become available, which allow diseases to be detected at the molecular level long before macroscopic symptoms appear. The past three years have seen an array of novel technological developments that have led to the first optical tomographic studies of small animals in the areas of cerebral ischemia and cancer.
Collapse
Affiliation(s)
- Andreas H Hielscher
- Department of Biomedical Engineering, Columbia University, ET351 Mudd Building, 500 West 120th Street, MC8904, New York, NY 10027, USA.
| |
Collapse
|
38
|
Godavarty A, Thompson AB, Roy R, Gurfinkel M, Eppstein MJ, Zhang C, Sevick-Muraca EM. Diagnostic imaging of breast cancer using fluorescence-enhanced optical tomography: phantom studies. JOURNAL OF BIOMEDICAL OPTICS 2004; 9:488-96. [PMID: 15189086 DOI: 10.1117/1.1691027] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Molecular targeting with exogenous near-infrared excitable fluorescent agents using time-dependent imaging techniques may enable diagnostic imaging of breast cancer and prognostic imaging of sentinel lymph nodes within the breast. However, prior to the administration of unproven contrast agents, phantom studies on clinically relevant volumes are essential to assess the benefits of fluorescence-enhanced optical imaging in humans. Diagnostic 3-D fluorescence-enhanced optical tomography is demonstrated using 0.5 to 1 cm(3) single and multiple targets differentiated from their surroundings by indocyanine green (micromolar) in a breast-shaped phantom (10-cm diameter). Fluorescence measurements of referenced ac intensity and phase shift were acquired in response to point illumination measurement geometry using a homodyned intensified charge-coupled device system modulated at 100 MHz. Bayesian reconstructions show artifact-free 3-D images (3857 unknowns) from 3-D boundary surface measurements (126 to 439). In a reflectance geometry appropriate for prognostic imaging of lymph node involvement, fluorescence measurements were likewise acquired from the surface of a semi-infinite phantom (8x8x8 cm(3)) in response to area illumination (12 cm(2)) by excitation light. Tomographic 3-D reconstructions (24,123 unknowns) were recovered from 2-D boundary surface measurements (3194) using the modified truncated Newton's method. These studies represent the first 3-D tomographic images from physiologically relevant geometries for breast imaging.
Collapse
Affiliation(s)
- A Godavarty
- Photon Migration Laboratory, Texas A&M University, College Station, TX 77843-3573, USA
| | | | | | | | | | | | | |
Collapse
|
39
|
Godavarty A, Eppstein MJ, Zhang C, Theru S, Thompson AB, Gurfinkel M, Sevick-Muraca EM. Fluorescence-enhanced optical imaging in large tissue volumes using a gain-modulated ICCD camera. Phys Med Biol 2003; 48:1701-20. [PMID: 12870578 DOI: 10.1088/0031-9155/48/12/303] [Citation(s) in RCA: 99] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A novel image-intensified charge-coupled device (ICCD) imaging system has been developed to perform 3D fluorescence tomographic imaging in the frequency-domain using near-infrared contrast agents. The imager is unique since it (i) employs a large tissue-mimicking phantom, which is shaped and sized to resemble a female breast and part of the extended chest-wall region, and (ii) enables rapid data acquisition in the frequency-domain by using a gain-modulated ICCD camera. Diffusion model predictions are compared to experimental measurements using two different referencing schemes under two different experimental conditions of perfect and imperfect uptake of fluorescent agent into a target. From these experimental measurements, three-dimensional images of fluorescent absorption were reconstructed using a computationally efficient variant of the approximate extended Kalman filter algorithm. The current work represents the first time that 3D fluorescence-enhanced optical tomographic reconstructions have been achieved from experimental measurements of the time-dependent light propagation on a clinically relevant breast-shaped tissue phantom using a gain-modulated ICCD camera.
Collapse
Affiliation(s)
- Anuradha Godavarty
- Department of Chemical Engineering, Texas A&M University, College Station, TX 77843-3122, USA
| | | | | | | | | | | | | |
Collapse
|