Vaidya VR, Asirvatham R, Kowlgi GN, Dai MY, Cochuyt JJ, Hodge DO, Deshmukh AJ, Cha YM. Trends in Cardiovascular Implantable Electronic Device Insertion Between 1988 and 2018 in Olmsted County.
JACC Clin Electrophysiol 2022;
8:88-100. [PMID:
34454890 PMCID:
PMC9339254 DOI:
10.1016/j.jacep.2021.06.006]
[Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 06/08/2021] [Accepted: 06/09/2021] [Indexed: 01/03/2023]
Abstract
OBJECTIVES
This study sought to describe trends in cardiovascular implantable electronic device (CIED) insertion over the past 3 decades in Olmsted County.
BACKGROUND
Trends in CIED insertion in the United States have not been extensively studied.
METHODS
The Rochester Epidemiology Project is a medical records linkage system comprising the records of all residents of Olmsted County from 1966 to the present. CIED insertion between 1988 and 2018 was determined using International Classification of Diseases-Ninth Revision, International Classification of Diseases-10th Revision, and Current Procedural Terminology codes. Age- and sex-adjusted incidence rates, adjusted to the 2010 US White population, were calculated. Trends in incidence over time, across age groups, and between sex are estimated using Poisson regression models.
RESULTS
The age- and sex-adjusted incidence of device implants for the study period were as follows: overall CIED: 82.4 (95% CI: 79.2-85.6); permanent pacemaker (PPM): 62.9 (95% CI: 60.0-65.7); implantable cardioverter-defibrillator (ICD): 14.0 (95% CI: 12.6-15.3); and cardiac resynchronization therapy (CRT): 5.6 (95% CI: 4.7-6.4) per 100,000 per year. The overall incidence of CIED insertion increased between 1988 to 1993 and 2000 to 2005 and then decreased between 2000 to 2005 and 2012 to 218 (P < 0.0001). PPM and ICD insertion incidence followed these trends, whereas the incidence of CRT insertion increased between 2000 to 2005 and 2012 to 2018. CIED insertion incidence increased with age (P < 0.0001). CIED insertion incidence was greater in men (116.3 vs 57.3 per 100,000 per year in men vs women; P < 0.0001). The overall survival of CRT recipients improved (P = 0.0044).
CONCLUSIONS
The incidence values for PPM and ICD implants are decreasing, while the incidence of CRT implants is increasing. CIEDs are increasingly inserted in the elderly, men, and patients with higher comorbidities.
Collapse