Felberer F, Rechenmacher M, Haindl R, Baumann B, Hitzenberger CK, Pircher M. Imaging of retinal vasculature using adaptive optics SLO/OCT. BIOMEDICAL OPTICS EXPRESS 2015; 6:1407-18. [PMID: 25909024 PMCID: PMC4399679 DOI: 10.1364/boe.6.001407] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2015] [Revised: 03/16/2015] [Accepted: 03/18/2015] [Indexed: 05/18/2023]
Abstract
We use our previously developed adaptive optics (AO) scanning laser ophthalmoscope (SLO)/ optical coherence tomography (OCT) instrument to investigate its capability for imaging retinal vasculature. The system records SLO and OCT images simultaneously with a pixel to pixel correspondence which allows a direct comparison between those imaging modalities. Different field of views ranging from 0.8°x0.8° up to 4°x4° are supported by the instrument. In addition a dynamic focus scheme was developed for the AO-SLO/OCT system in order to maintain the high transverse resolution throughout imaging depth. The active axial eye tracking that is implemented in the OCT channel allows time resolved measurements of the retinal vasculature in the en-face imaging plane. Vessel walls and structures that we believe correspond to individual erythrocytes could be visualized with the system.
Collapse
Affiliation(s)
- Franz Felberer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| | - Matthias Rechenmacher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| | - Richard Haindl
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringerguertel 18-20, 1090 Vienna,
Austria
- Imaging Cluster, Medical University of Vienna,
Austria
| |
Collapse
|
3
|
|
4
|
Hofer H, Sredar N, Queener H, Li C, Porter J. Wavefront sensorless adaptive optics ophthalmoscopy in the human eye. OPTICS EXPRESS 2011; 19:14160-71. [PMID: 21934779 PMCID: PMC3178895 DOI: 10.1364/oe.19.014160] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Revised: 06/26/2011] [Accepted: 06/27/2011] [Indexed: 05/18/2023]
Abstract
Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the same system. A stochastic parallel gradient descent algorithm directly optimized the mean intensity in retinal image frames acquired with a confocal adaptive optics scanning laser ophthalmoscope (AOSLO). When imaging through natural, undilated pupils, both control methods resulted in comparable mean image intensities. However, when imaging through dilated pupils, image intensity was generally higher following wavefront sensor-based control. Despite the typically reduced intensity, image contrast was higher, on average, with sensorless control. Wavefront sensorless control is a viable option for imaging the living human eye and future refinements of this technique may result in even greater optical gains.
Collapse
Affiliation(s)
- Heidi Hofer
- College of Optometry, University of Houston, Houston Texas 77204, USA.
| | | | | | | | | |
Collapse
|
5
|
Abstract
Retinal imaging with conventional methods is only able to overcome the lowest order of aberration, defocus and astigmatism. The human eye is fraught with higher order of aberrations. Since we are forced to use the human optical system in retinal imaging, the images are degraded. In addition, all of these distortions are constantly changing due to head/eye movement and change in accommodation. Adaptive optics is a promising technology introduced in the field of ophthalmology to measure and compensate for these aberrations. High-resolution obtained by adaptive optics enables us to view and image the retinal photoreceptors, retina pigment epithelium, and identification of cone subclasses in vivo. In this review we will be discussing the basic technology of adaptive optics and hardware requirement in addition to clinical applications of such technology.
Collapse
Affiliation(s)
- Babak Jian Seyedahmadi
- Retina Service, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA 02114, USA.
| | | |
Collapse
|
6
|
Bao H, Rao C, Zhang Y, Dai Y, Rao X, Fan Y. Hybrid filtering and enhancement of high-resolution adaptive-optics retinal images. OPTICS LETTERS 2009; 34:3484-3486. [PMID: 19927185 DOI: 10.1364/ol.34.003484] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Adaptive optics flood-illuminated imaging technology has been successfully used to correct the wavefront aberration of human eyes to obtain high-resolution retinal images. However, because of the pollution of various types of noise and the degradation caused by residual aberration, the noisy images are not very clear and weak edges are difficult to discern. To reveal the abundant detail hidden by large-scale noise and to enhance low-contrast edges, a hybrid filtering and enhancement method is proposed combining bilateral filtering, coherence diffusion, and edge enhancement. Results show that it is effective to improve the visual quality of retinal cell images.
Collapse
Affiliation(s)
- Hua Bao
- Key Lab on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China
| | | | | | | | | | | |
Collapse
|
7
|
Imanishi Y, Lodowski K, Koutalos Y. Two-photon microscopy: shedding light on the chemistry of vision. Biochemistry 2007; 46:9674-84. [PMID: 17676772 PMCID: PMC2718834 DOI: 10.1021/bi701055g] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Two-photon microscopy (TPM) has come to occupy a prominent place in modern biological research with its ability to resolve the three-dimensional distribution of molecules deep inside living tissue. TPM can employ two different types of signals, fluorescence and second harmonic generation, to image biological structures with subcellular resolution. Two-photon excited fluorescence imaging is a powerful technique with which to monitor the dynamic behavior of the chemical components of tissues, whereas second harmonic imaging provides novel ways to study their spatial organization. Using TPM, great strides have been made toward understanding the metabolism, structure, signal transduction, and signal transmission in the eye. These include the characterization of the spatial distribution, transport, and metabolism of the endogenous retinoids, molecules essential for the detection of light, as well as the elucidation of the architecture of the living cornea. In this review, we present and discuss the current applications of TPM for the chemical and structural imaging of the eye. In addition, we address what we see as the future potential of TPM for eye research. This relatively new method of microscopy has been the subject of numerous technical improvements in terms of the optics and indicators used, improvements that should lead to more detailed biochemical characterizations of the eyes of live animals and even to imaging of the human eye in vivo.
Collapse
Affiliation(s)
- Yoshikazu Imanishi
- Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, Ohio
- To whom correspondence should be addressed:Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, Ohio 44106-4965. Phone: 216-368-5226. Fax: 216-368-1300. E-mail: (Y. I.); Department of Ophthalmology, Medical University of South, Carolina, Charleston, South Carolina 29425. Phone:843-792-9180. Fax: 843-792-1723. E-mail:(Y. K.)
| | - Kerrie Lodowski
- Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, Ohio
| | - Yiannis Koutalos
- Department of Ophthalmology, Medical University of South Carolina, Charleston, South, Carolina
- To whom correspondence should be addressed:Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, Ohio 44106-4965. Phone: 216-368-5226. Fax: 216-368-1300. E-mail: (Y. I.); Department of Ophthalmology, Medical University of South, Carolina, Charleston, South Carolina 29425. Phone:843-792-9180. Fax: 843-792-1723. E-mail:(Y. K.)
| |
Collapse
|
8
|
Doble N, Miller DT, Yoon G, Williams DR. Requirements for discrete actuator and segmented wavefront correctors for aberration compensation in two large populations of human eyes. APPLIED OPTICS 2007; 46:4501-14. [PMID: 17579706 PMCID: PMC2654185 DOI: 10.1364/ao.46.004501] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Numerous types of wavefront correctors have been employed in adaptive optics (AO) systems for correcting the ocular wavefront aberration. While all have improved image quality, none have yielded diffraction-limited imaging for large pupils (>/=6 mm), where the aberrations are most severe and the benefit of AO the greatest. To this end, we modeled the performance of discrete actuator, segmented piston-only, and segmented piston/tip/tilt wavefront correctors in conjunction with wavefront aberrations measured on normal human eyes in two large populations. The wavefront error was found to be as large as 53 microm, depending heavily on the pupil diameter (2-7.5 mm) and the particular refractive state. The required actuator number for diffraction-limited imaging was determined for three pupil sizes (4.5, 6, and 7.5 mm), three second-order aberration states, and four imaging wavelengths (0.4, 0.6, 0.8, and 1.0 microm). The number across the pupil varied from only a few actuators in the discrete case to greater than 100 for the piston-only corrector. The results presented will help guide the development of wavefront correctors for the next generation of ophthalmic instrumentation.
Collapse
Affiliation(s)
- Nathan Doble
- Center for Visual Science, 274 Meliora Hall, University of Rochester, Rochester, New York 14627, USA.
| | | | | | | |
Collapse
|
9
|
van Velthoven MEJ, Faber DJ, Verbraak FD, van Leeuwen TG, de Smet MD. Recent developments in optical coherence tomography for imaging the retina. Prog Retin Eye Res 2006; 26:57-77. [PMID: 17158086 DOI: 10.1016/j.preteyeres.2006.10.002] [Citation(s) in RCA: 211] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Optical coherence tomography (OCT) was introduced in ophthalmology a decade ago. Within a few years in vivo imaging of the healthy retina and optic nerve head and of retinal diseases was a fact. In particular the ease with which these images can be acquired considerably changed the diagnostic strategy used by ophthalmologists. The OCT technique currently available in clinical practice is referred to as time-domain OCT, because the depth information of the retina is acquired as a sequence of samples, over time. This can be done either in longitudinal cross-sections perpendicular to, or in the coronal plane parallel to the retinal surface. Only recently, major advances have been made as to image resolution with the introduction of ultrahigh resolution OCT and in imaging speed, signal-to-noise ratio and sensitivity with the introduction of spectral-domain OCT. Functional OCT is the next frontier in OCT imaging. For example, polarization-sensitive OCT uses the birefringent characteristics of the retinal nerve fibre layer to better assess its thickness. Blood flow information from retinal vessels as well as the oxygenation state of retinal tissue can be extracted from the OCT signal. Very promising are the developments in contrast-enhanced molecular optical imaging, for example with the use of scattering tuneable nanoparticles targeted at specific tissue or cell structures. This review will provide an overview of these most recent developments in the field of OCT imaging focussing on applications for the retina.
Collapse
Affiliation(s)
- Mirjam E J van Velthoven
- Department of Ophthalmology, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands.
| | | | | | | | | |
Collapse
|
10
|
Choi SS, Doble N, Hardy JL, Jones SM, Keltner JL, Olivier SS, Werner JS. In vivo imaging of the photoreceptor mosaic in retinal dystrophies and correlations with visual function. Invest Ophthalmol Vis Sci 2006; 47:2080-92. [PMID: 16639019 PMCID: PMC2583223 DOI: 10.1167/iovs.05-0997] [Citation(s) in RCA: 124] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE To relate in vivo microscopic retinal changes to visual function in patients who have various forms of retinal dystrophy. METHODS The UC Davis Adaptive Optics (AO) fundus camera was used to acquire in vivo retinal images at the cellular level. Visual function tests consisting of visual fields, multifocal electroretinography (mfERG), and contrast sensitivity were measured in all subjects by using stimuli that were coincident with areas imaged. Five patients with different forms of retinal dystrophy and three control subjects were recruited. Cone densities were quantified for all retinal images. RESULTS In all images of diseased retinas, there were extensive areas of dark space between groups of photoreceptors, where no cone photoreceptors were evident. These irregular features were not seen in healthy retinas, but were apparent in patients with retinal dystrophy. There were significant correlations between functional vision losses and the extent to which these irregularities, quantified by cone density, occurred in retinal images. CONCLUSIONS AO fundus imaging is a reliable technique for assessing and quantifying the changes in the photoreceptor layer as disease progresses. Furthermore, this technique can be useful in cases where visual function tests provide borderline or ambiguous results, as it allows visualization of individual photoreceptors.
Collapse
Affiliation(s)
- Stacey S Choi
- Department of Ophthalmology & Vision Science, University of California Davis, Sacramento 95817, USA.
| | | | | | | | | | | | | |