Morany A, Bardon RG, Lavon K, Hamdan A, Bluestein D, Haj-Ali R. Analysis of fibrocalcific aortic valve stenosis: computational pre-and-post TAVR haemodynamics behaviours. ROYAL SOCIETY OPEN SCIENCE 2024; 11:230905. [PMID: 38384780 PMCID: PMC10878817 DOI: 10.1098/rsos.230905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Figures] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 01/22/2024] [Indexed: 02/23/2024]
Abstract
Fibro-calcific aortic valve (AV) diseases are characterized by calcium growth or accumulation of fibrosis in the AV tissues. Fibrocalcific aortic stenosis (FAS) rises specifically in females, like calcification-induced aortic stenosis (CAS), may eventually necessitate valve replacement. Fluid-structure-interaction (FSI) computational models for severe CAS and FAS patients were developed using lattice Boltzmann method and multi-scale finite elements (FE). Three parametric AV models were introduced: pathology-free of non-calcified tri-and-bicuspid AVs with healthy collagen fibre network (CFN), a FAS model incorporated a thickened CFN with embedded small calcification volumes, and a CAS model employs healthy CFN with embedded high calcification volumes. The results indicate that the interaction between calcium deposits, adjacent tissue and fibres crucially influences haemodynamics and structural reactions. A fourth model of transcatheter aortic valve replacement (TAVR) post-procedure outcomes was created to study both CAS and FAS. TAVR-CAS had a higher maximum contact pressure and lower anchoring area than TAVR-FAS, making it prone to aortic tissue damage and migration. Finally, although the TAVR-CAS offered a larger opening area, its paravalvular leakage was higher. This may be attributed to a similar thrombogenicity potential characterizing both models. The computational framework emphasizes the significance of mechanobiology in FAS and underscores the requirement for tissue modelling at multiple scales.
Collapse
Affiliation(s)
- Adi Morany
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Karin Lavon
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Ashraf Hamdan
- Department of Cardiology, Rabin Medical Center, Petach Tikva, Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Rami Haj-Ali
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| |
Collapse
|
2
|
Chen A, Azriff Basri A, Ismail NB, Arifin Ahmad K. Hemodynamic Effects of Subaortic Stenosis on Blood Flow Characteristics of a Mechanical Heart Valve Based on OpenFOAM Simulation. Bioengineering (Basel) 2023; 10:312. [PMID: 36978704 PMCID: PMC10045469 DOI: 10.3390/bioengineering10030312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 02/22/2023] [Accepted: 02/28/2023] [Indexed: 03/06/2023] Open
Abstract
Subaortic stenosis (SAS) is a common congenital heart disease that can cause significant morbidity and mortality if not treated promptly. Patients with heart valve disease are prone to complications after replacement surgery, and the existence of SAS can accelerates disease progression, so timely diagnosis and treatment are required. However, the effects of subaortic stenosis on mechanical heart valves (MHV) are unknown. This study aimed to investigate flow characteristics in the presence of subaortic stenosis and computationally quantify the effects on the hemodynamics of MHV. Through the numerical simulation method, the flow characteristics and related parameters in the presence of SAS can be more intuitively observed. Based on its structure, there are three types of SAS: Tunnel-type SAS (TSS); Fibromuscular annulus SAS (FSS); Discrete SAS (DSS). The first numerical simulation study on different types of SAS found that there are obvious differences among them. Among them, the tunnel-type SAS formed a separated vortex structure on the tunnel-type narrow surface, which exhibits higher wall shear force at a low obstacle percentage. However, discrete SAS showed obvious differences when there was a high percentage of obstacles, forming high peak flow, high wall shear stress, and a high-intensity complex vortex. The presence of all three types of SAS results in the formation of high-velocity jets and complex vortices in front of the MHV, leading to increased shear stress and stagnation time. These hemodynamic changes significantly increase the risk of MHV dysfunction and the development of complications. Despite differences between the three types of SAS, the resultant effects on MHV hemodynamics are consistent. Therefore, early surgical intervention is warranted in SAS patients with implanted MHV.
Collapse
Affiliation(s)
- Aolin Chen
- Department of Mechanical Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Adi Azriff Basri
- Department of Aerospace Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Norzian Bin Ismail
- Department of Medicine, Faculty of Medicine and Health Sciences, University Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| | - Kamarul Arifin Ahmad
- Department of Aerospace Engineering, Faculty of Engineering, University Putra Malaysia, Serdang 43400, Selangor, Malaysia;
| |
Collapse
|
3
|
Kovarovic BJ, Rotman OM, Parikh PB, Slepian MJ, Bluestein D. Mild Paravalvular Leak May Pose an Increased Thrombogenic Risk in Transcatheter Aortic Valve Replacement (TAVR) Patients-Insights from Patient Specific In Vitro and In Silico Studies. Bioengineering (Basel) 2023; 10:188. [PMID: 36829682 PMCID: PMC9952825 DOI: 10.3390/bioengineering10020188] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/27/2023] [Accepted: 01/30/2023] [Indexed: 02/05/2023] Open
Abstract
In recent years, the treatment of aortic stenosis with TAVR has rapidly expanded to younger and lower-risk patients. However, persistent thrombotic events such as stroke and valve thrombosis expose recipients to severe clinical complications that hamper TAVR's rapid advance. We presented a novel methodology for establishing a link between commonly acceptable mild paravalvular leak (PVL) levels through the device and increased thrombogenic risk. It utilizes in vitro patient-specific TAVR 3D-printed replicas evaluated for hydrodynamic performance. High-resolution µCT scans are used to reconstruct in silico FSI models of these replicas, in which multiple platelet trajectories are studied through the PVL channels to quantify thrombogenicity, showing that those are highly dependent on patient-specific flow conditions within the PVL channels. It demonstrates that platelets have the potential to enter the PVL channels multiple times over successive cardiac cycles, increasing the thrombogenic risk. This cannot be reliably approximated by standard hemodynamic parameters. It highlights the shortcomings of subjectively ranked PVL commonly used in clinical practice by indicating an increased thrombogenic risk in patient cases otherwise classified as mild PVL. It reiterates the need for more rigorous clinical evaluation for properly diagnosing thrombogenic risk in TAVR patients.
Collapse
Affiliation(s)
- Brandon J. Kovarovic
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Oren M. Rotman
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| | - Puja B. Parikh
- Division of Cardiovascular Medicine, Department of Medicine, Stony Brook University, Stony Brook, NY 11794, USA
| | - Marvin J. Slepian
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ 85724, USA
- Department of Biomedical Engineering, College of Engineering, University of Arizona, Tucson, AZ 85721, USA
| | - Danny Bluestein
- Biofluids Research Group, Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY 11794, USA
| |
Collapse
|
4
|
Li Y, Xi Y, Wang H, Sun A, Deng X, Chen Z, Fan Y. The impact of rotor configurations on hemodynamic features, hemocompatibility and dynamic balance of the centrifugal blood pump: A numerical study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2023; 39:e3671. [PMID: 36507614 DOI: 10.1002/cnm.3671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 09/11/2022] [Accepted: 12/04/2022] [Indexed: 06/17/2023]
Abstract
To investigate the effect of rotor design configuration on hemodynamic features, hemocompatibility and dynamic balance of blood pumps. Computational fluid dynamics was employed to investigate the effects of rotor type (closed impeller, semi-open impeller), clearance height and back vanes on blood pump performance. In particular, the Eulerian hemolysis model based on a power-law function and the Lagrangian thrombus model with integrated stress accumulation and residence time were applied to evaluate the hemocompatibility of the blood pump. This study shows that compared to the closed impeller, the semi-open impeller can improve hemolysis at a slight sacrifice in head pressure, but increase the risk of thrombogenic potential and disrupt rotor dynamic balance. For the semi-open impeller, the pressure head, hemolysis, and axial thrust of the blood pump decrease with increasing front clearance, and the risk of thrombosis increases first and then decreases with increasing front clearance. Variations in back clearance have little effect on pressure head, but larger on back clearance, worsens hemolysis, thrombogenic potential and rotor dynamic balance. The employment of back vanes has little effect on the pressure head. All back vanes configurations have an increased risk of hemolysis in the blood pump but are beneficial for the improvement of the rotor dynamic balance of the blood pump. Reasonable back vanes configuration (higher height, wider width, longer length and more number) decreases the flow separation, increases the velocity of blood in the back clearance, and reduces the risk of blood pooling and thrombosis. It was also found that hemolysis index (HI) was highly negatively correlated with pressure difference between the top and back clearances (r = -.87), and thrombogenic potential was positively correlated with pressure difference between the top and back clearances (r = .71). This study found that rotor type, clearance height, and back vanes significantly affect the hydraulic performance, hemocompatibility and rotor dynamic balance of centrifugal blood pumps through secondary flow. These parameters should be carefully selected when designing and optimizing centrifugal blood pumps for improving the blood pump clinical outcomes.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Anqiang Sun
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
5
|
Li Y, Wang H, Xi Y, Sun A, Deng X, Chen Z, Fan Y. A New Mathematical Numerical Model to Evaluate the Risk of Thrombosis in Three Clinical Ventricular Assist Devices. Bioengineering (Basel) 2022; 9:bioengineering9060235. [PMID: 35735478 PMCID: PMC9219778 DOI: 10.3390/bioengineering9060235] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 05/17/2022] [Accepted: 05/25/2022] [Indexed: 11/24/2022] Open
Abstract
(1) Background: Thrombosis is the main complication in patients supported with ventricular assist devices (VAD). Models that accurately predict the risk of thrombus formation in VADs are still lacking. When VADs are clinically assisted, their complex geometric configuration and high rotating speed inevitably generate complex flow fields and high shear stress. These non-physiological factors can damage blood cells and proteins, release coagulant factors and trigger thrombosis. In this study, a more accurate model for thrombus assessment was constructed by integrating parameters such as shear stress, residence time and coagulant factors, so as to accurately assess the probability of thrombosis in three clinical VADs. (2) Methods: A mathematical model was constructed to assess platelet activation and thrombosis within VADs. By solving the transport equation, the influence of various factors such as shear stress, residence time and coagulation factors on platelet activation was considered. The diffusion equation was applied to determine the role of activated platelets and substance deposition on thrombus formation. The momentum equation was introduced to describe the obstruction to blood flow when thrombus is formed, and finally a more comprehensive and accurate model for thrombus assessment in patients with VAD was obtained. Numerical simulations of three clinically VADs (CH-VAD, HVAD and HMII) were performed using this model. The simulation results were compared with experimental data on platelet activation caused by the three VADs. The simulated thrombogenic potential in different regions of MHII was compared with the frequency of thrombosis occurring in the regions in clinic. The regions of high thrombotic risk for HVAD and HMII observed in experiments were compared with the regions predicted by simulation. (3) Results: It was found that the percentage of activated platelets within the VAD obtained by solving the thrombosis model developed in this study was in high agreement with the experimental data (r² = 0.984), the likelihood of thrombosis in the regions of the simulation showed excellent correlation with the clinical statistics (r² = 0.994), and the regions of high thrombotic risk predicted by the simulation were consistent with the experimental results. Further study revealed that the three clinical VADs (CH-VAD, HVAD and HMII) were prone to thrombus formation in the inner side of the secondary flow passage, the clearance between cone and impeller, and the corner region of the inlet pipe, respectively. The risk of platelet activation and thrombus formation for the three VADs was low to high for CH-VAD, HVAD, and HM II, respectively. (4) Conclusions: In this study, a more comprehensive and accurate thrombosis model was constructed by combining parameters such as shear stress, residence time, and coagulation factors. Simulation results of thrombotic risk received with this model showed excellent correlation with experimental and clinical data. It is important for determining the degree of platelet activation in VAD and identifying regions prone to thrombus formation, as well as guiding the optimal design of VAD and clinical treatment.
Collapse
|
6
|
Li Y, Yu J, Wang H, Xi Y, Deng X, Chen Z, Fan Y. Investigation of the influence of blade configuration on the hemodynamic performance and blood damage of the centrifugal blood pump. Artif Organs 2022; 46:1817-1832. [PMID: 35436361 DOI: 10.1111/aor.14265] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 03/01/2022] [Accepted: 04/08/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE The design and optimization of centrifugal blood pumps is crucial for improved extracorporeal membrane oxygenation system performances. Secondary flow passages are common in centrifugal blood pumps, allowing for a high volume of unstable flow. Traditional design theory offers minimal guidance on the design and optimization of centrifugal blood pumps, so it's critical to understand how design parameter variables affect hydraulic performances and hemocompatibility. METHODS Computational fluid dynamics (CFD) was employed to investigate the effects of blade number, blade wrap angle, blade thickness, and splitters on pressure head, hemolysis, and platelet activation state. Eulerian and Lagrangian features were used to analyze the flow fields and hemocompatibility metrics such as scalar shear stress, velocity distribution, and their correlation. RESULTS The equalization of frictional and flow losses allow impellers with more blades and smaller wrap angles to have higher pressure heads, whereas the trade-off between the volume of high scalar shear stress and exposure time allows impellers with fewer blades and larger blade wrap angles to have a lower HI; there are configurations that increase the possibility of platelet activation for both number of blades and wrap angles. The hydraulic performance and hemocompatibility of centrifugal blood pumps are not affected by blade thickness. Compared to the main blades, a splitters can improve the blood compatibility of a centrifugal blood pump with a small reduction in pressure head, but there is a trade-off between the length and location of the splitter that suppresses flow losses while reducing the velocity gradient. According to correlation analysis, pressure head, HI, and the volume of high shear stress were all substantially connected, and exposure time had a significant impact on HI. The platelet activation state was influenced by the average scalar shear stress and the volume of low velocity. CONCLUSION The findings reveal the impact of design variables on the performance of centrifugal blood pumps with secondary flow passages, as well as the relationship between hemocompatibility, hydraulic performance, and flow characteristics, and are useful for the design and optimization of this type of blood pump, as well as the prediction of clinical complications.
Collapse
Affiliation(s)
- Yuan Li
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Jiachen Yu
- School of Sino-french Engineer, Beihang University, Beijing, 100083, China
| | - Hongyu Wang
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Yifeng Xi
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Xiaoyan Deng
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Zengsheng Chen
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| | - Yubo Fan
- Key Laboratory of Biomechanics and Mechanobiology (Beihang University), Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, 100083, China
| |
Collapse
|
7
|
A new way to evaluate thrombotic risk in failure heart and ventricular assist devices. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2022. [DOI: 10.1016/j.medntd.2022.100135] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
8
|
The effect of turbulence modelling on the assessment of platelet activation. J Biomech 2021; 128:110704. [PMID: 34482226 DOI: 10.1016/j.jbiomech.2021.110704] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 07/24/2021] [Accepted: 08/16/2021] [Indexed: 11/21/2022]
Abstract
Pathological platelet activation by abnormal shear stresses is regarded as a main clinical complication in recipients of cardiovascular mechanical devices. In order to improve their performance computational fluid dynamics (CFD) are used to evaluate flow fields and related shear stresses. CFD models are coupled with mathematical models that describe the relation between fluid dynamics variables, and in particular shear stresses, and the platelet activation state (PAS). These models typically use a Lagrangian approach to compute the shear stresses along possible platelet trajectories. However, in the case of turbulent flow, the choice of the proper turbulence closure is still debated for both concerning its effect on shear stress calculation and Lagrangian statistics. In this study different numerical simulations of the flow through a mechanical heart valve were performed and then compared in terms of Eulerian and Lagrangian quantities: a direct numerical simulation (DNS), a large eddy simulation (LES), two Reynolds-averaged Navier-Stokes (RANS) simulations (SST k-ω and RSM) and a "laminar" (no turbulence modelling) simulation. Results exhibit a large variability in the PAS assessment depending on the turbulence model adopted. "Laminar" and RSM estimates of platelet activation are about 60% below DNS, while LES is 16% less. Surprisingly, PAS estimated from the SST k- ω velocity field is only 8% less than from DNS data. This appears more artificial than physical as can be inferred after comparing frequency distributions of PAS and of the different Lagrangian variables of the mechano-biological model of platelet activation. Our study indicates how much turbulence closures may affect platelet activation estimates, in comparison to an accurate DNS, when assessing blood damage in blood contacting devices.
Collapse
|
9
|
Plitman Mayo R, Yaakobovich H, Finkelstein A, Shadden SC, Marom G. Impact of BASILICA on the thrombogenicity potential of valve-in-valve implantations. J Biomech 2021; 118:110309. [PMID: 33601181 DOI: 10.1016/j.jbiomech.2021.110309] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 02/03/2021] [Indexed: 01/17/2023]
Abstract
Subclinical leaflet thrombosis is becoming a major concern in valve-in-valve procedures, whereby a transcatheter aortic valve device is deployed inside a failed bioprosthetic surgical valve. Blood flow stagnation and prolonged residence times in the neo-sinuses have been suggested as possible explanations for leaflet thrombosis. The BASILICA technique, which was originally developed to treat coronary flow obstruction, has also been proposed as an alternative to reduce the risk of thrombus formation. The aim of this study is to understand the impact of BASILICA on the valve-in-valve thrombogenicity using computational fluid dynamics simulations. To this end, two Eulerian and two Lagrangian approaches were employed to estimate near-wall stagnation measures in eight valve-in-valve models. The models included an intact or lacerated Sorin Mitroflow surgical valve, and either a SAPIEN or Evolut transcatheter aortic valve device. The Lagrangian approaches predicted a high number of particles and vortices concentration in the proximal areas of the neo-sinuses, while the Eulerian approaches did so in the distal areas. As a consequence, this study demonstrated that Lagrangian approaches are better predictors of subclinical leaflet thrombosis, since they match experimental and clinical findings. Additionally, the SAPIEN valve possess a higher risk for developing leaflet thrombosis, and two lacerations are shown to provide the best results in terms of development of vortices and accumulation of particles within the neo-sinuses. This study highlights the potential of computational modeling in aiding clinicians in their decision-making in valve-in-valve and BASILICA procedures.
Collapse
Affiliation(s)
| | - Halit Yaakobovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Shawn C Shadden
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
10
|
Plitman Mayo R, Yaakobovich H, Finkelstein A, Shadden SC, Marom G. Numerical models for assessing the risk of leaflet thrombosis post-transcatheter aortic valve-in-valve implantation. ROYAL SOCIETY OPEN SCIENCE 2020; 7:201838. [PMID: 33489295 PMCID: PMC7813235 DOI: 10.1098/rsos.201838] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Accepted: 11/20/2020] [Indexed: 05/04/2023]
Abstract
Leaflet thrombosis has been suggested as the reason for the reduced leaflet motion in cases of hypoattenuated leaflet thickening of bioprosthetic aortic valves. This work aimed to estimate the risk of leaflet thrombosis in two post-valve-in-valve (ViV) configurations, using five different numerical approaches. Realistic ViV configurations were calculated by modelling the deployments of the latest version of transcatheter aortic valve devices (Medtronic Evolut PRO, Edwards SAPIEN 3) in the surgical Sorin Mitroflow. Computational fluid dynamics simulations of blood flow followed the dry models. Lagrangian and Eulerian measures of near-wall stagnation were implemented by particle and concentration tracking, respectively, to estimate the thrombogenicity and to predict the risk locations. Most of the numerical approaches indicate a higher leaflet thrombosis risk in the Edwards SAPIEN 3 device because of its intra-annular implantation. The Eulerian approaches estimated high-risk locations in agreement with the wall sheer stress (WSS) separation points. On the other hand, the Lagrangian approaches predicted high-risk locations at the proximal regions of the leaflets matching the low WSS magnitude regions of both transcatheter aortic valve implantation models and reported clinical and experimental data. The proposed methods can help optimizing future designs of transcatheter aortic valves with minimal thrombotic risks.
Collapse
Affiliation(s)
- Romina Plitman Mayo
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
- Department of Biological Regulation, Weizmann Institute of Science, Herzl Street 234, Rehovot, Israel
| | - Halit Yaakobovich
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| | | | - Shawn C. Shadden
- Department of Mechanical Engineering, University of California, Berkeley, CA, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
11
|
Bozzi S, Vesentini S, Santus M, Ghelli N, Fontanili P, Corbelli M, Fiore GB, Redaelli ACL. Fluid dynamics characterization and thrombogenicity assessment of a levitating centrifugal pump with different impeller designs. Med Eng Phys 2020; 83:26-33. [PMID: 32807345 DOI: 10.1016/j.medengphy.2020.07.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 07/14/2020] [Accepted: 07/18/2020] [Indexed: 11/16/2022]
Abstract
Technical guidelines nowadays recommend and regulate the use Computational Fluid Dynamics (CFD) to assess the performance of medical devices. CFD coupled to blood damage models has emerged as a powerful tool to evaluate the hemocompatibility of blood recirculating devices. The present study is aimed at evaluating the hydrodynamic performance and the thrombogenic potential of two prototypes of magnetically levitating centrifugal pumps. The two devices differ in the impeller configuration - 6-blades vs. 12-blades - and have been designed to be used in Cardiopulmonary Bypass (CPB) circuits during open heart surgery and in Extracorporeal Membrane Oxygenation (ECMO) to support patients with severe cardiac or respiratory failure. The pumps have been modelled using Direct Numerical Simulation coupled to Lagrangian analysis to predict platelet activation due to abnormal shear stress histories. Numerical results have been compared with experimental data in terms of head generation for different working points. Results show that the 6-blades pump has i) smaller stagnation areas, ii) lower stress levels and iii) higher strain rate, resulting in a lower thrombogenic potential, whereas the 12-blade impeller guarantees a more stable performance at high flow rates, suggesting its preferential use for more demanding applications, such as CPB.
Collapse
Affiliation(s)
- Silvia Bozzi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy.
| | - Simone Vesentini
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Marco Santus
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Nicola Ghelli
- EUROSETS S.r.l., Strada Statale 12, no143, 41036 Medolla (MO), Italy
| | - Paolo Fontanili
- EUROSETS S.r.l., Strada Statale 12, no143, 41036 Medolla (MO), Italy
| | - Marco Corbelli
- EUROSETS S.r.l., Strada Statale 12, no143, 41036 Medolla (MO), Italy
| | - Gianfranco B Fiore
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| | - Alberto C L Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan, Italy
| |
Collapse
|
12
|
Abstract
Heart valve diseases are common disorders with five million annual diagnoses being made in the United States alone. All heart valve disorders alter cardiac hemodynamic performance; therefore, treatments aim to restore normal flow. This paper reviews the state-of-the-art clinical and engineering advancements in heart valve treatments with a focus on hemodynamics. We review engineering studies and clinical literature on the experience with devices for aortic valve treatment, as well as the latest advancements in mitral valve treatments and the pulmonic and tricuspid valves on the right side of the heart. Upcoming innovations will potentially revolutionize treatment of heart valve disorders. These advancements, and more gradual enhancements in the procedural techniques and imaging modalities, could improve the quality of life of patients suffering from valvular disease who currently cannot be treated.
Collapse
Affiliation(s)
- Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv Israel
- To whom correspondence should be addressed. E-mail:
| | - Shmuel Einav
- Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
13
|
Large-Eddy Simulations of Flow in the FDA Benchmark Nozzle Geometry to Predict Hemolysis. Cardiovasc Eng Technol 2020; 11:254-267. [PMID: 32297154 DOI: 10.1007/s13239-020-00461-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Accepted: 03/29/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE Modeling of hemolysis due to fluid stresses faces significant methodological challenges, particularly in geometries with turbulence or complex flow patterns. It is currently unclear how existing phenomenological blood-damage models based on laminar viscous stresses can be implemented into turbulent computational fluid dynamics simulations. The aim of this work is to generalize the existing laminar models to turbulent flows based on first principles, and validate this generalization with existing experimental data. METHODS A novel analytical and numerical framework for the simulation of flow-induced hemolysis based on the intermittency-corrected turbulent viscous shear stress (ICTVSS) is introduced. The proposed large-eddy simulation framework is able to seamlessly transition from laminar to turbulent conditions in a single flow domain by linking laminar shear stresses to dissipation of mechanical energy, accounting for intermittency in turbulent dissipation, and relying on existing power-law hemolysis models. Simulations are run to reproduce previously published hemolysis data with bovine blood in a benchmark geometry. Two sets of experimental data are relied upon to tune power-law parameters and justify that tuning. The first presents hemolysis measurements in a simple laminar flow, and the second is hemolysis in turbulent flow through the FDA benchmark nozzle. Validation is performed by simulation of blood injected into a turbulent jet of phosphate-buffered saline, with modifications made to account for the local concentration of blood. RESULTS Hemolysis predictions are found to be very sensitive to power-law parameters in the turbulent case, though a set of parameters is presented that both matches the turbulent data and is well-justified by the laminar data. The model is shown to be able to predict the general behavior of hemolysis in a second turbulent case. Results suggest that wall shear may play a dominant role in most cases. CONCLUSION The ICTVSS framework of generalizing laminar power-law models to turbulent flows shows promise, but would benefit from further numerical validation and carefully designed experiments.
Collapse
|
14
|
Ghosh RP, Marom G, Bianchi M, D'souza K, Zietak W, Bluestein D. Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid-structure interaction analysis. Biomech Model Mechanobiol 2020; 19:1725-1740. [PMID: 32095912 DOI: 10.1007/s10237-020-01304-9] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Accepted: 02/02/2020] [Indexed: 01/11/2023]
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure that provides an effective alternative to open-heart surgical valve replacement for treating advanced calcific aortic valve disease patients. However, complications, such as valve durability, device migration, paravalvular leakage (PVL), and thrombogenicity may lead to increased overall post-TAVR morbidity and mortality. A series of numerical studies involving a self-expandable TAVR valve were performed to evaluate these complications. Structural studies were performed with finite element (FE) analysis, followed by computational fluid dynamics (CFD) simulations, and fluid-structure interaction (FSI) analysis. The FE analysis was utilized to study the effect of TAVR valve implantation depth on valve anchorage in the Living Heart Human Model, which is capable of simulating beating heart during repeated cardiac cycles. The TAVR deployment cases where no valve migration was observed were then used to calculate the post-deployment thrombogenic potential via CFD simulations. FSI analysis followed to further assess the post-deployment TAVR hemodynamic performance for different implantation depths. The deployed valves PVL, geometric and effective orifice areas, and the leaflets structural and flow stress magnitudes were compared to determine the device optimal landing zone. The combined structural and hemodynamic analysis indicated that with the TAVR valve deployed at an aft ventricle position an optimal performance was achieved in the specific anatomy studied. Given the TAVR's rapid expansion to younger lower-risk patients, the comprehensive numerical methodology proposed here can potentially be used as a predictive tool for both procedural planning and valve design optimization to minimize the reported complications.
Collapse
Affiliation(s)
- Ram P Ghosh
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Tel Aviv, Israel
| | - Matteo Bianchi
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA
| | - Karl D'souza
- Dassault Systèmes SIMULIA Corp, Johnston, RI, 02919, USA
| | - Wojtek Zietak
- Capvidia NV, Research Park Haasrode, Technologielaan 3, 3001, Leuven, Belgium
| | - Danny Bluestein
- Department of Biomedical Engineering, Health Sciences Center T08-050, Stony Brook University, Stony Brook, NY, 11794-8084, USA.
| |
Collapse
|
15
|
Li M, Walk R, Roka-Moiia Y, Sheriff J, Bluestein D, Barth EJ, Slepian MJ. Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution. Artif Organs 2019; 44:E226-E237. [PMID: 31876310 DOI: 10.1111/aor.13626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/20/2019] [Accepted: 12/16/2019] [Indexed: 12/28/2022]
Abstract
Mechanical circulatory support (MCS) devices continue to be hampered by thrombotic adverse events (AEs), a consequence of device-imparted supraphysiologic shear stresses, leading to shear-mediated platelet activation (SMPA). In advancing MCS devices from design to clinical use, in vitro circulatory loops containing the device under development and testing are utilized as a means of assessing device thrombogenicity. Physical characteristics of these test circulatory loops may also contribute to inadvertent platelet activation through imparted shear stress, adding inadvertent error in evaluating MCS device thrombogenicity. While investigators normally control for the effect of a loop, inadvertent addition of what are considered innocuous connectors may impact test results. Here, we tested the effect of common, additive components of in vitro circulatory test loops, that is, connectors and loop geometry, as to their additive contribution to shear stress via both in silico and in vitro models. A series of test circulatory loops containing a ventricular assist device (VAD) with differing constituent components, were established in silico including: loops with 0~5 Luer connectors, a loop with a T-connector creating 90° angulation, and a loop with 90° angulation. Computational fluid dynamics (CFD) simulations were performed using a k - ω shear stress transport turbulence model to platelet activation index (PAI) based on a power law model. VAD-operated loops replicating in silico designs were assembled in vitro and gel-filtered human platelets were recirculated within (1 hour) and SMPA was determined. CFD simulations demonstrated high shear being introduced at non-smooth regions such as edge-connector boundaries, tubing, and at Luer holes. Noticeable peaks' shifts of scalar shear stress (sss) distributions toward high shear-region existed with increasing loop complexity. Platelet activation also increased with increasing shear exposure time, being statistically higher when platelets were exposed to connector-employed loop designs. The extent of platelet activation in vitro could be successfully predicted by CFD simulations. Loops employing additional components (non-physiological flow pattern connectors) resulted in higher PAI. Loops with more components (5-connector loop and 90° T-connector) showed 63% and 128% higher platelet activation levels, respectively, versus those with fewer (0-connector (P = .023) and a 90° heat-bend loop (P = .0041). Our results underscore the importance of careful consideration of all component elements, and suggest the need for standardization in designing in vitro circulatory loops for MCS device evaluation to avoid inadvertent additive SMPA during device evaluation, confounding overall results. Specifically, we caution on the use and inadvertent introduction of additional connectors, ports, and other shear-generating elements which introduce artifact, clouding primary device evaluation via introduction of additive SMPA.
Collapse
Affiliation(s)
- Mengtang Li
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Ryan Walk
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - Yana Roka-Moiia
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - Eric J Barth
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA
| | - Marvin J Slepian
- Department of Medicine, Sarver Heart Center, University of Arizona, Tucson, AZ, USA.,Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA.,Department of Biomedical Engineering, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
16
|
Left Ventricular Assist Device Inflow Cannula Insertion Depth Influences Thrombosis Risk. ASAIO J 2019; 66:766-773. [DOI: 10.1097/mat.0000000000001068] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
17
|
Combined In Silico and In Vitro Approach Predicts Low Wall Shear Stress Regions in a Hemofilter that Correlate with Thrombus Formation In Vivo. ASAIO J 2019; 64:211-217. [PMID: 28857774 DOI: 10.1097/mat.0000000000000649] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
A major challenge in developing blood-contacting medical devices is mitigating thrombogenicity of an intravascular device. Thrombi may interfere with device function or embolize from the device to occlude distant vascular beds with catastrophic consequences. Chemical interactions between plasma proteins and bioengineered surface occur at the nanometer scale; however, continuum models of blood predict local shear stresses that lead to platelet activation or aggregation and thrombosis. Here, an iterative approach to blood flow path design incorporating in silico, in vitro, and in vivo experiments predicted the occurrence and location of thrombi in an implantable hemofilter. Low wall shear stress (WSS) regions identified by computational fluid dynamics (CFD) predicted clot formation in vivo. Revised designs based on CFD demonstrated superior performance, illustrating the importance of a multipronged approach for a successful design process.
Collapse
|
18
|
Device Thrombogenicity Emulation: An In Silico Predictor of In Vitro and In Vivo Ventricular Assist Device Thrombogenicity. Sci Rep 2019; 9:2946. [PMID: 30814674 PMCID: PMC6393420 DOI: 10.1038/s41598-019-39897-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Accepted: 02/04/2019] [Indexed: 12/02/2022] Open
Abstract
Ventricular assist devices (VAD), a mainstay of therapy for advanced and end-stage heart failure, remain plagued by device thrombogenicity. Combining advanced in silico and in vitro methods, Device Thrombogenicity Emulation (DTE) is a device design approach for enhancing VAD thromboresistance. Here we tested DTE efficacy in experimental VAD designs. DTE incorporates iterative design modifications with advanced CFD to compute the propensity of large populations of platelets to activate by flow-induced stresses (statistically representing the VAD ‘Thrombogenic Footprint’). The DTE approach was applied to a VAD (MINDTE) design with a favorable thromboresistance profile and compared against a design (MAXDTE) that generated an intentionally poor thromboresistance profile. DTE predictions were confirmed by testing physical prototypes in vitro by measuring VAD thrombogenicity using the modified prothrombinase assay. Chronic in vivo studies in VAD implanted calves, revealed MINDTE calf surviving well with low platelet activation, whereas the MAXDTE animal sustained thromboembolic strokes. DTE predictions were confirmed, correlating with in vitro and in vivo thrombogenicity, supporting utility in guiding device development, potentially reducing the need for animal studies.
Collapse
|
19
|
Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage. Biomech Model Mechanobiol 2018; 18:435-451. [PMID: 30460623 DOI: 10.1007/s10237-018-1094-8] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2018] [Accepted: 11/01/2018] [Indexed: 10/27/2022]
Abstract
Transcatheter aortic valve replacement (TAVR) has emerged as an effective alternative to conventional surgical valve replacement in high-risk patients afflicted by severe aortic stenosis. Despite newer-generation devices enhancements, post-procedural complications such as paravalvular leakage (PVL) and related thromboembolic events have been hindering TAVR expansion into lower-risk patients. Computational methods can be used to build and simulate patient-specific deployment of transcatheter aortic valves (TAVs) and help predict the occurrence and degree of PVL. In this study finite element analysis and computational fluid dynamics were used to investigate the influence of procedural parameters on post-deployment hemodynamics on three retrospective clinical cases affected by PVL. Specifically, TAV implantation depth and balloon inflation volume effects on stent anchorage, degree of paravalvular regurgitation and thrombogenic potential were analyzed for cases in which Edwards SAPIEN and Medtronic CoreValve were employed. CFD results were in good agreement with corresponding echocardiography data measured in patients in terms of the PVL jets locations and overall PVL degree. Furthermore, parametric analyses demonstrated that positioning and balloon over-expansion may have a direct impact on the post-deployment TAVR performance, achieving as high as 47% in PVL volume reduction. While the model predicted very well clinical data, further validation on a larger cohort of patients is needed to verify the level of the model's predictions in various patient-specific conditions. This study demonstrated that rigorous and realistic patient-specific numerical models could potentially serve as a valuable tool to assist physicians in pre-operative TAVR planning and TAV selection to ultimately reduce the risk of clinical complications.
Collapse
|
20
|
Marom G, Eswaran SK, Rapoza RJ, Hossainy SFA, Slepian MJ, Bluestein D. Design Effect of Metallic (Durable) and Polymeric (Resorbable) Stents on Blood Flow and Platelet Activation. Artif Organs 2018; 42:1148-1156. [DOI: 10.1111/aor.13276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Revised: 03/13/2018] [Accepted: 04/13/2018] [Indexed: 01/08/2023]
Affiliation(s)
- Gil Marom
- Department of Biomedical Engineering; Stony Brook University; Stony Brook NY USA
- School of Mechanical Engineering; Tel Aviv University; Tel Aviv Israel
| | | | | | | | - Marvin J. Slepian
- Department of Biomedical Engineering; Stony Brook University; Stony Brook NY USA
- Departments of Medicine and Biomedical Engineering; Sarver Heart Center, University of Arizona; Tucson AZ USA
| | - Danny Bluestein
- Department of Biomedical Engineering; Stony Brook University; Stony Brook NY USA
| |
Collapse
|
21
|
Buck AKW, Goebel SG, Goodin MS, Wright NJ, Groszek JJ, Moyer J, Singh S, Bluestein D, Fissell WH, Roy S. Original article submission: Platelet stress accumulation analysis to predict thrombogenicity of an artificial kidney. J Biomech 2018; 69:26-33. [PMID: 29395231 DOI: 10.1016/j.jbiomech.2018.01.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 12/27/2017] [Accepted: 01/08/2018] [Indexed: 02/01/2023]
Abstract
An implantable artificial kidney using a hemofilter constructed from an array of silicon membranes to provide ultrafiltration requires a suitable blood flow path to ensure stable operation in vivo. Two types of flow paths distributing blood to the array of membranes were evaluated: parallel and serpentine. Computational fluid dynamics (CFD) simulations were used to guide the development of the blood flow paths. Pressure data from animal tests were used to obtain pulsatile flow conditions imposed in the transient simulations. A key consideration for stable operation in vivo is limiting platelet stress accumulation to avoid platelet activation and thrombus formation. Platelet stress exposure was evaluated by CFD particle tracking methods through the devices to provide distributions of platelet stress accumulation. The distributions of stress accumulation over the duration of a platelet lifetime for each device revealed that stress accumulation for the serpentine flow path exceeded levels expected to cause platelet activation while the accumulated stress for the parallel flow path was below expected activation levels.
Collapse
Affiliation(s)
- Amanda K W Buck
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | | | | | - Nathan J Wright
- Department of Bioengineering & Therapeutic Sciences, University of California San Francisco, San Francisco, CA, USA
| | - Joseph J Groszek
- Nephrology and Hypertension, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jarrett Moyer
- Department of Surgery, University of California San Francisco, San Francisco, CA, USA
| | - Sukhveer Singh
- Department of Surgery, University of California San Francisco, San Francisco, CA, USA
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
| | - William H Fissell
- Nephrology and Hypertension, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Shuvo Roy
- Department of Bioengineering & Therapeutic Sciences, University of California San Francisco, San Francisco, CA, USA.
| |
Collapse
|
22
|
Consolo F, Sheriff J, Gorla S, Magri N, Bluestein D, Pappalardo F, Slepian MJ, Fiore GB, Redaelli A. High Frequency Components of Hemodynamic Shear Stress Profiles are a Major Determinant of Shear-Mediated Platelet Activation in Therapeutic Blood Recirculating Devices. Sci Rep 2017; 7:4994. [PMID: 28694489 PMCID: PMC5503983 DOI: 10.1038/s41598-017-05130-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Accepted: 05/25/2017] [Indexed: 11/25/2022] Open
Abstract
We systematically analyzed the relative contributions of frequency component elements of hemodynamic shear stress waveforms encountered in cardiovascular blood recirculating devices as to overall platelet activation over time. We demonstrated that high frequency oscillations are the major determinants for priming, triggering and yielding activated “prothrombotic behavior” for stimulated platelets, even if the imparted shear stress has low magnitude and brief exposure time. Conversely, the low frequency components of the stress signal, with limited oscillations over time, did not induce significant activation, despite being of high magnitude and/or exposure time. In vitro data were compared with numerical predictions computed according to a recently proposed numerical model of shear-mediated platelet activation. The numerical model effectively resolved the correlation between platelet activation and the various frequency components examined. However, numerical predictions exhibited a different activation trend compared to experimental results for different time points of a stress activation sequence. With this study we provide a more fundamental understanding for the mechanobiological responsiveness of circulating platelets to the hemodynamic environment of cardiovascular devices, and the importance of these environments in mediating life-threatening thromboembolic complications associated with shear-mediated platelet activation. Experimental data will guide further optimization of the thromboresistance of cardiovascular implantable therapeutic devices.
Collapse
Affiliation(s)
- Filippo Consolo
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy. .,Anesthesia and Cardiothoracic Intensive Care, IRCCS San Raffaele Scientific Institute, Vita Salute University, Milan, Italy.
| | - Jawaad Sheriff
- Department of Biomedical Engineering, Stony Brook University, New York, USA
| | - Silvia Gorla
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Nicolò Magri
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, New York, USA
| | - Federico Pappalardo
- Anesthesia and Cardiothoracic Intensive Care, IRCCS San Raffaele Scientific Institute, Vita Salute University, Milan, Italy
| | - Marvin J Slepian
- Department of Biomedical Engineering, Stony Brook University, New York, USA.,Department of Medicine and Biomedical Engineering, Sarver Heart Center, The University of Arizona, Arizona, USA
| | - Gianfranco B Fiore
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| |
Collapse
|
23
|
Bluestein D. Utilizing Computational Fluid Dynamics in Cardiovascular Engineering and Medicine-What You Need to Know. Its Translation to the Clinic/Bedside. Artif Organs 2017; 41:117-121. [PMID: 28181302 DOI: 10.1111/aor.12914] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Danny Bluestein
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794-8181, USA
| |
Collapse
|
24
|
Reynolds Stresses and Hemolysis in Turbulent Flow Examined by Threshold Analysis. FLUIDS 2016. [DOI: 10.3390/fluids1040042] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
25
|
Chaux A, Gray RJ, Stupka JC, Emken MR, Scotten LN, Siegel R. Anticoagulant independent mechanical heart valves: viable now or still a distant holy grail. ANNALS OF TRANSLATIONAL MEDICINE 2016; 4:525. [PMID: 28149886 DOI: 10.21037/atm.2016.12.58] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Valvular heart disease remains a large public health problem for all societies; it attracts the attention of public health organizations, researchers and governments. Valve substitution is an integral part of the treatment for this condition. At present, the choice of valve prosthesis is either tissue or mechanical. Tissue valves have become increasingly popular in spite of unresolved problems with durability, hemodynamics, cost and need for anticoagulation therapy. As a consequence, mechanical valve innovation has virtually ceased; the last successful mechanical design is 25 years old. We postulate that with improved technology, knowledge and experience gained over the last quarter century, the best possible solution to the problem of valve substitution can be achieved with a mechanical valve that is anticoagulant independent, durable, hemodynamically and cost efficient. At present, it is possible to design, test and produce a valve that can accomplish these goals.
Collapse
Affiliation(s)
- Aurelio Chaux
- Visiting Scientist Cedars Sinai Medical Center Heart Institute, Los Angeles, CA, USA
| | - Richard J Gray
- Medical Director Tyler Heart Institute, Community Hospital of the Monterey Peninsula, CA, USA
| | | | | | | | | |
Collapse
|
26
|
Faghih MM, Keith Sharp M. Extending the Power-Law Hemolysis Model to Complex Flows. J Biomech Eng 2016; 138:2556264. [DOI: 10.1115/1.4034786] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Indexed: 11/08/2022]
Abstract
Hemolysis (damage to red blood cells) is a long-standing problem in blood contacting devices, and its prediction has been the goal of considerable research. The most popular model relating hemolysis to fluid stresses is the power-law model, which was developed from experiments in pure shear only. In the absence of better data, this model has been extended to more complex flows by replacing the shear stress in the power-law equation with a von Mises-like scalar stress. While the validity of the scalar stress also remains to be confirmed, inconsistencies exist in its application, in particular, two forms that vary by a factor of 2 have been used. This article will clarify the proper extension of the power law to complex flows in a way that maintains correct results in the limit of pure shear.
Collapse
Affiliation(s)
- Mohammad M. Faghih
- Biofluid Mechanics Laboratory, Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292
| | - M. Keith Sharp
- Biofluid Mechanics Laboratory, Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292
| |
Collapse
|