1
|
Agarwal P, Kambala SR, Dubey SR, Bhoyar A, Doshi K. Application of Strain Elastography in Dentistry: A Systematic Review. Cureus 2024; 16:e70693. [PMID: 39493060 PMCID: PMC11529695 DOI: 10.7759/cureus.70693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2024] [Accepted: 10/02/2024] [Indexed: 11/05/2024] Open
Abstract
Strain elastography, a non-invasive imaging technique complements traditional diagnostic methods by offering quantitative and qualitative information about soft and hard tissues within the oral cavity. The article aimed to provide an overview of the currently available data on the use of strain elastography in dentistry. To support the review of strain elastography applications in dentistry, a wide range of articles was searched using both online and offline databases. Inclusion and exclusion criteria were defined according to the Population, Intervention, Comparison, Outcomes, and Study Design (PICOS) approach. The results show that 12 of the 107 papers found to be eligible for inclusion in a qualitative examination of the use of strain elastography in dentistry satisfied the PICOS criteria. Elastography is a promising tool for diagnosing various dental diseased conditions, but sufficient evidence is not available. More studies on a larger population should be performed to determine its accuracy in diagnosis.
Collapse
Affiliation(s)
- Pragati Agarwal
- Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Seema R Kambala
- Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Surekha R Dubey
- Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Anjali Bhoyar
- Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Khushbu Doshi
- Department of Prosthodontics, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
2
|
Toscano RA, Barbosa S, Campos LG, de Sousa CA, Dallazen E, Mourão CF, Shibli JA, Ervolino E, Faverani LP, Assunção WG. The Addition of Hydroxyapatite Nanoparticles on Implant Surfaces Modified by Zirconia Blasting and Acid Etching to Enhance Peri-Implant Bone Healing. Int J Mol Sci 2024; 25:7321. [PMID: 39000425 PMCID: PMC11242766 DOI: 10.3390/ijms25137321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 06/24/2024] [Accepted: 06/28/2024] [Indexed: 07/16/2024] Open
Abstract
This study investigated the impact of adding hydroxyapatite nanoparticles to implant surfaces treated with zirconia blasting and acid etching (ZiHa), focusing on structural changes and bone healing parameters in low-density bone sites. The topographical characterization of titanium discs with a ZiHa surface and a commercially modified zirconia-blasted and acid-etched surface (Zi) was performed using scanning electron microscopy, profilometry, and surface-free energy. For the in vivo assessment, 22 female rats were ovariectomized and kept for 90 days, after which one implant from each group was randomly placed in each tibial metaphysis of the animals. Histological and immunohistochemical analyses were performed at 14 and 28 days postoperatively (decalcified lab processing), reverse torque testing was performed at 28 days, and histometry from calcified lab processing was performed at 60 days The group ZiHa promoted changes in surface morphology, forming evenly distributed pores. For bone healing, ZiHa showed a greater reverse torque, newly formed bone area, and bone/implant contact values compared to group Zi (p < 0.05; t-test). Qualitative histological and immunohistochemical analyses showed higher features of bone maturation for ZiHa on days 14 and 28. This preclinical study demonstrated that adding hydroxyapatite to zirconia-blasted and acid-etched surfaces enhanced peri-implant bone healing in ovariectomized rats. These findings support the potential for improving osseointegration of dental implants, especially in patients with compromised bone metabolism.
Collapse
Affiliation(s)
- Ricardo Alves Toscano
- Department of Diagnosis and Surgery, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Stéfany Barbosa
- Department of Diagnosis and Surgery, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Larissa Gabriele Campos
- Department of Diagnosis and Surgery, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Cecília Alves de Sousa
- Department of Dental Materials and Prosthodontics, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Eduardo Dallazen
- Department of Diagnosis and Surgery, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Carlos Fernando Mourão
- Department of Periodontology, School of Dentistry, Tufts University, Boston, MA 02111, USA
| | - Jamil Awad Shibli
- Dental Research Division, Department of Periodontology and Oral Implantology, University of Guarulhos (UnG), Guarulhos 07115-230, Brazil
| | - Edilson Ervolino
- Department of Basic Science, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16018-800, Brazil
| | - Leonardo P Faverani
- Department of Diagnosis and Surgery, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| | - Wirley Goncalves Assunção
- Department of Dental Materials and Prosthodontics, Sao Paulo State University-UNESP, Aracatuba School of Dentistry, Sao Paulo 16015-050, Brazil
| |
Collapse
|
3
|
Lechner J, von Baehr V, Notter F, Schick F. Osseointegration and osteoimmunology in implantology: assessment of the immune sustainability of dental implants using advanced sonographic diagnostics: research and case reports. J Int Med Res 2024; 52:3000605231224161. [PMID: 38259068 PMCID: PMC10807457 DOI: 10.1177/03000605231224161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 12/15/2023] [Indexed: 01/24/2024] Open
Abstract
OBJECTIVE Bone marrow defects of the jaw (BMDJ) surrounding dental implants, in combination with impaired bone-to-implant contact (BIC), are difficult to detect in X-rays. This study evaluated BMDJ surrounding titanium (Ti-Impl) and ceramic (Cer-Impl) dental implants and incomplete BIC using a new trans-alveolar ultrasonography device (TAU) with numerical scaling for BIC. METHODS The titanium stimulation test (Ti-Stim) was used to detect immune overactivation in response to titanium. Bone density surrounding implants was measured using TAU. We also validated osteoimmune dysregulation. RESULTS TAU values showed reduced BIC and decreased osseointegration for Ti-Impl. Moreover, TAU values in the Cer-Impl group were more than twice those in the Ti-Impl cohort. The multiplex analysis of C-C motif chemokine 5 (CCL5, also known as RANTES) expression revealed a 20-fold increase in BMDJ surrounding Ti-Impl. Higher levels of CCL5 inflammation were present in the positive Ti-Stim group. CONCLUSIONS Our data indicate that Cer-Impl have an osteoimmune advantage over Ti-Impl. The key determinant for osteoimmune sustainability appears to be the absence of inflammation at the implant site. We therefore recommend the use of TAU to assess the implant site prior to implantation.
Collapse
Affiliation(s)
| | - Volker von Baehr
- Department of Immunology and Allergology, Institute for Medical Diagnostics, Berlin, Germany
| | | | | |
Collapse
|
4
|
Matos FG, Stremel ACA, Lipinski LC, Cirelli JA, Dos Santos FA. Dental implants in large animal models with experimental systemic diseases: A systematic review. Lab Anim 2023; 57:489-503. [PMID: 37021606 DOI: 10.1177/00236772221124972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
This systematic review aims to identify and discuss the most used methodologies in pre-clinical studies for the evaluation of the implementation of dental implants in systemically compromised pigs and sheep. This study provides support and guidance for future research, as well as for the prevention of unnecessary animal wastage and sacrifice. Preferred Reporting for Systematic Reviews and Meta-Analyses (PRISMA) was used as a guideline; electronic searches were performed in PubMed, Scopus, Scielo, Web of Science, Embase, Science Direct, Brazilian Bibliography of Dentistry, Latin American and Caribbean Literature in Health Sciences, Directory of Open Access Journals, Database of Abstracts of Reviews of Effects, and gray literature until January 2022 (PROSPERO/CRD42021270119). Sixty-eight articles were chosen from the 2439 results. Most studies were conducted in pigs, mainly the Göttinger and Domesticus breeds. Healthy animals with implants installed in the jaws were predominant among the pig studies. Of the studies evaluating the effect of systemic diseases on osseointegration, 42% were performed in osteoporotic sheep, 32% in diabetic sheep, and 26% in diabetic pigs. Osteoporosis was primarily induced by bilateral ovariectomy and mainly assessed by X-ray densitometry. Diabetes was induced predominantly by intravenous streptozotocin and was confirmed by blood glucose analysis. Histological and histomorphometric analyses were the most frequently employed in the evaluation of osseointegration. The animal models presented unique methodologies for each species in the studies that evaluated dental implants in the context of systemic diseases. Understanding the most commonly used techniques will help methodological choices and the performance of future studies in implantology.
Collapse
Affiliation(s)
| | | | | | - Joni Augusto Cirelli
- Department of Diagnosis and Surgery, School of Dentistry at Araraquara, State University of São Paulo (Unesp), Brazil
| | | |
Collapse
|
5
|
Özmeriç N, Çakal GÖ, Gökmenoğlu C, Özmeriç A, Oduncuoğlu BF, Hacaloğlu T, Kaftanoğlu B. Histomorphometric and biomechanical evaluation of the osseointegration around micro- and nano-level boron-nitride coated titanium dental implants. JOURNAL OF STOMATOLOGY, ORAL AND MAXILLOFACIAL SURGERY 2022; 123:e694-e700. [PMID: 35724866 DOI: 10.1016/j.jormas.2022.06.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/08/2022] [Accepted: 06/16/2022] [Indexed: 10/18/2022]
Abstract
INTRODUCTION Titanium dental implants has been coated with different materials such as polymers and biomimetic agents, bone morphogenetic protein, calcium phosphate to enhance surface properties of the titanium implants for osseointegration. The aim of this study was to evaluate the bone tissue healing around Boron Nitride-coated (BN-coated) titanium implants histomorphometrically and biomechanically and also observe the effect of different coating thicknesses on osseointegration. MATERIALS AND METHODS BN was coated on dental titanium implants with two different coating thicknesses by using RF magnetron sputtering system. Totally fifty-four implants were inserted into the tibias' of 12 New Zealand rabbits bilaterally under general anesthesia. All animals were sacrificed after 4-weeks. Bone-implant contact (BIC) and new bone area/total area ratios (BATA) were calculated. Also, the removal torque (RT) test was performed. RESULTS The highest new bone area in the medullary cavity was around the nano-BN-coated surface with 15.70%. In micro-BN-coated surface and control group, this ratio was determined as 10.48% and 8.23%, respectively. The BIC ratios in upper-side of implants and cortical-associated BIC ratios in lower-side were found significantly higher in control and micro-BN-coated group than nano-BN-coated group (p < 0.05). Similar BIC values were observed between control and micro-BN-coated groups (p > 0.05). BATA values did not show statistically significant differences between all three groups (p > 0.05). The RT values measured in all groups were found comparable and no statistically significant differences were found (p > 0.05). CONCLUSION No inflammatory reaction developed around any implant. Relatively more new bone formation around nano-BN-coated titanium implants indicates the promising osseoinductive effect of BN coating. BN-coated implants showed similar biomechanical and histomorphometrical outcomes to that of the conventional titanium implants through a 4-week evaluation period.
Collapse
Affiliation(s)
- Nurdan Özmeriç
- Department of Periodontology, Faculty of Dentistry, Gazi University, Bişkek Caddesi, 06510 Ankara, Turkey
| | - Gaye Özgür Çakal
- Institute of Nuclear Sciences, Ankara University, Tandoğan Campus, 06100 Ankara, Turkey
| | - Ceren Gökmenoğlu
- Department of Periodontology, Faculty of Dentistry, Ordu University, 52100, Ordu, Turkey.
| | - Ahmet Özmeriç
- Department of Orthopedics and Traumatology, SBU Ankara Training and Research Hospital, 06340 Ankara, Turkey
| | - Bahar Füsun Oduncuoğlu
- Department of Periodontology, Faculty of Dentistry, Baskent University, 06590 Ankara, Turkey
| | - Tuğçe Hacaloğlu
- Department of Manufacturing Engineering, Atilim University, Kizilcasar Mah 06836 Ankara, Turkey
| | - Bilgin Kaftanoğlu
- Department of Manufacturing Engineering, Atilim University, Kizilcasar Mah 06836 Ankara, Turkey
| |
Collapse
|
6
|
Aldebes A, Al-Khanati NM, Abou Nassar J, Kharboutly NAD, Aldamman F. Effect of restoration material on marginal bone resorption around modified anatomic zirconia dental implants: A randomised controlled trial. Ann Med Surg (Lond) 2022; 80:104313. [PMID: 36045765 PMCID: PMC9422372 DOI: 10.1016/j.amsu.2022.104313] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 07/27/2022] [Accepted: 07/27/2022] [Indexed: 11/17/2022] Open
Abstract
Objective The primary aim of this study was to determine the effect of implant-supported porcelain-fused-to-metal (PFM) and indirect-composite-resin (ICR) fixed dental prostheses on peri-implant marginal bone resorption (MBR) in custom-made anatomic modified zirconia dental implants. Methods A prospective randomized controlled clinical trial was conducted. Participants with premolars indicated for dental extractions were recruited into this study to receive a single-unit implant-supported fixed dental prosthesis. Modified anatomic zirconia implants with thorny-retentive surfaces were placed and loaded randomly after 3 months with either PFM or ICR crowns. Participants were recalled after 12 and 18 months for radiographic evaluation of peri-implant MBR. Implants survival was also reported. Results 18 out of 20 zirconia implants were included in all study phases. 18-month survival rate was 90%. After 12 months of implant placement, the mean MBR values were 0.53 (±0.21) mm and 0.60 (±0.14) mm in the ICR group compared to 0.67 (±0.16) mm and 0.61 (±0.27) mm in the PFM group. In the 18-month follow-up, the mean MBR values were 0.61 (±0.27) and 0.67 (±0.16) mm in the ICR group compared to 0.77 (±0.29) and 0.77 (±0.27) mm in the PFM group. No significant differences were found in MBR mean values between study groups at 12- and 18-month follow-up points. Conclusion This study showed that PFM and ICR crowns were viable zirconia-implant-supported restorations with no preference regarding MBR after 18 months. Nevertheless, long-term evaluations are warranted. Custom-made zirconia implants with new design of their macro-retentive features (thorns) were used in this clinical study. They showed success rate of 90% with all failures occurred early before loading. Peri-implant marginal bone resorption (MBR) ranged within acceptable values after 12 and 18 months. No significant differences in MBRs were seen between implant-supported metal-ceramic and indirect composite restorations.
Collapse
Affiliation(s)
- Alaa Aldebes
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| | - Nuraldeen Maher Al-Khanati
- Department of Oral and Maxillofacial Surgery, Faculty of Dental Medicine, Damascus University, Damascus, Syria
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Syrian Private University, Damascus, Syria
- Corresponding author. Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Syrian Private University, P.O. Box 36822, Damascus, Syria. ,
| | - Jihad Abou Nassar
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| | - Nour Al-Deen Kharboutly
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| | - Feras Aldamman
- Department of Fixed Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria
| |
Collapse
|
7
|
A Biocompatible Ultrananocrystalline Diamond (UNCD) Coating for a New Generation of Dental Implants. NANOMATERIALS 2022; 12:nano12050782. [PMID: 35269268 PMCID: PMC8911871 DOI: 10.3390/nano12050782] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/09/2022] [Accepted: 02/17/2022] [Indexed: 02/04/2023]
Abstract
Implant therapy using osseointegratable titanium (Ti) dental implants has revolutionized clinical dental practice and has shown a high rate of success. However, because a metallic implant is in contact with body tissues and fluids in vivo, ions/particles can be released into the biological milieu as a result of corrosion or biotribocorrosion. Ultrananocrystalline diamond (UNCD) coatings possess a synergistic combination of mechanical, tribological, and chemical properties, which makes UNCD highly biocompatible. In addition, because the UNCD coating is made of carbon (C), a component of human DNA, cells, and molecules, it is potentially a highly biocompatible coating for medical implant devices. The aim of the present research was to evaluate tissue response to UNCD-coated titanium micro-implants using a murine model designed to evaluate biocompatibility. Non-coated (n = 10) and UNCD-coated (n = 10) orthodontic Ti micro-implants were placed in the hematopoietic bone marrow of the tibia of male Wistar rats. The animals were euthanized 30 days post implantation. The tibiae were resected, and ground histologic sections were obtained and stained with toluidine blue. Histologically, both groups showed lamellar bone tissue in contact with the implants (osseointegration). No inflammatory or multinucleated giant cells were observed. Histomorphometric evaluation showed no statistically significant differences in the percentage of BIC between groups (C: 53.40 ± 13% vs. UNCD: 58.82 ± 9%, p > 0.05). UNCD showed good biocompatibility properties. Although the percentage of BIC (osseointegration) was similar in UNCD-coated and control Ti micro-implants, the documented tribological properties of UNCD make it a superior implant coating material. Given the current surge in the use of nano-coatings, nanofilms, and nanostructured surfaces to enhance the biocompatibility of biomedical implants, the results of the present study contribute valuable data for the manufacture of UNCD coatings as a new generation of superior dental implants.
Collapse
|
8
|
Jing T, Yi Liu, Xu L, Chen C, Liu F. The incorporation of β-tricalcium phosphate nanoparticles within silk fibroin composite scaffolds for enhanced bone regeneration: An in vitro and in vivo study. J Biomater Appl 2022; 36:1567-1578. [PMID: 35135370 DOI: 10.1177/08853282211065621] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
To investigate the osteogenesis of β-tricalcium phosphate nanoparticles-incorporated silk fibroin (SF/β-TCP) composite scaffolds, SF-based scaffolds with different β-TCP proportion (2/1, 1/1, and 1/2) were fabricated by freeze-drying technology in the present study. Structural and physicochemical properties of SF-based scaffolds were evaluated by using scanning electron microscope, X-ray diffraction, Fourier transformed infrared spectroscopy (ATR-FTIR) and transmission electron microscope. Biocompatibility and osteogenesis of SF/β-TCP scaffolds were investigated by using bone marrow mesenchymal stem cells (BMSCs). Eight New Zealand rabbits were selected, while four 8-mm-diameter calvarial defects were created in each rabbit to place SF/β-TCP scaffolds. The harvested specimens at 4 and 12 weeks were used to evaluate the bone forming ability by micro-CT and histological examination. The results suggested incorporation of β-TCP displayed flake-like pore morphology with proper pore sizes. With the increasing proportion of β-TCP, composite scaffolds exhibited higher compressive strength, lower swelling ratio and degradation rate, as well as enhanced biomineralization capacity. Alkaline phosphatase activity and collagen type I expression levels of BMSCs were significantly increased in the presence of β-TCP nanoparticles. All composite scaffolds with different β-TCP proportion had good bone formation ability at 12 weeks. Among them, SF/β-TCP (1/2) scaffold exhibited the favorable osteogenesis capability which had great potential for applications in bone regeneration.
Collapse
Affiliation(s)
- Tienan Jing
- Department of Oral Mucosa Disease, School and Hospital of Stomatology, China Medical University, Shenyang, China
| | - Yi Liu
- Department of Orthodontics, School and Hospital of Stomatology, 162778China Medical University, Shenyang, China
| | - Li Xu
- Department of Laboratory Medicine, First Hospital of China Medical University, Shenyang, China
| | - Cen Chen
- College of Life College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou China
| | - Fan Liu
- Department of Orthodontics, School and Hospital of Stomatology, 162778China Medical University, Shenyang, China
| |
Collapse
|
9
|
Hériveaux Y, Nguyen VH, Haïat G. Ultrasonic Evaluation of the Bone-Implant Interface. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:373-396. [DOI: 10.1007/978-3-030-91979-5_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Early Bone Healing on Hydroxyapatite-Coated and Chemically-Modified Hydrophilic Implant Surfaces in an Ovine Model. Int J Mol Sci 2021; 22:ijms22179361. [PMID: 34502270 PMCID: PMC8430562 DOI: 10.3390/ijms22179361] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/21/2021] [Accepted: 08/21/2021] [Indexed: 11/17/2022] Open
Abstract
Implant topography affects early peri-implant bone healing by changing the osteoconduction rate in the surrounding biological environment. Implant surfaces have been designed to promote faster and stronger bone formation for rapid and stable prosthesis loading. Early peri-implant bone healing has been observed with a sandblasted, acid-etched implant that was chemically modified to be hydrophilic (cmSLA). The present study investigates whether early peri-implant bone healing extends to a rough surface implant with a high crystalline hydroxyapatite surface (TSV MP-1 HA). Three implants were randomly placed in porous trabecular bone within both medial femoral condyles of 10 sheep. Early peri-implant bone stability was measured at 3- and 6-weeks healing time following implant insertion. Results indicated a similar implant stability quotient between the implants at insertion and over time. The significant increase over time of reverse torque values with respect to insertion torque (p < 0.001) did not differ between the implants. However, the bone-to-implant contact of TSV MP-1 HA was significantly higher than that of cmSLA implants at 6 weeks (p < 0.01). These data validate previous findings of a hydrophilic implant surface and extend the observation of early osseointegration to a rough surface implant in porous trabecular bone.
Collapse
|
11
|
Hériveaux Y, Vayron R, Fraulob M, Lomami HA, Lenormand C, Haïat G. Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods. J Prosthodont Res 2021; 65:421-427. [PMID: 33177307 DOI: 10.2186/jpr.jpr_d_20_00052] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose Quantitative ultrasound (QUS) and resonance frequency analyses (RFA) are promising methods to assess the stability of dental implants. The aim of this in vivo preclinical study is to compare the results obtained with these two techniques with the bone-implant contact (BIC) ratio, which is the gold standard to assess dental implant stability.Methods Twenty-two identical dental implants were inserted in the tibia and femur of 12 rabbits, which were sacrificed after different healing durations (0, 4, 8 and 13 weeks). For each implant, the ultrasonic indicator (UI) and the implant stability quotient (ISQ) were retrieved just before the animal sacrifice using the QUS and RFA techniques, respectively. Histomorphometric analyses were carried out to estimate the bone-implant contact ratio.Results UI values were found to be better correlated to BIC values (R²=0.47) compared to ISQ values (R²=0.39 for measurements in one direction and R²=0.18 for the other direction), which were shown to be dependent on the direction of measurements. Errors realized on the UI were around 3.3 times lower to the ones realized on the ISQ.Conclusions QUS provide a better estimation of dental implant stability compared to RFA. This study paves the way for the future clinical development of a medical device aiming at assessing dental implant stability in a patient-specific manner. Clinical studies should confirm these results in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Romain Vayron
- Université Polytechnique des Hauts de France, Laboratoire d'Automatique, de Mécanique et d'informatique Industrielles et Humaines, Valenciennes, France
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Hugues Albini Lomami
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Camille Lenormand
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| |
Collapse
|
12
|
Effect of Implant Surface Modification on Bone Mineral Density and Survival Rate in the Maxilla After a Short Period Using Cone Beam Computed Tomography. J Craniofac Surg 2021; 33:e49-e52. [PMID: 34292234 DOI: 10.1097/scs.0000000000007908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
ABSTRACT This study was aimed to objectively measure the changes in bone density amount obtained through cone-beam computed tomography around dental implants after a short period of time in the maxilla. Thirty-two SLActive Straumann implants were inserted into 12 healthy patients. Changes in bone density were measured at the surgery time (Bone mineral density (BMD)0) and 60 days after investment (Bone mineral density (BMD)60). Statistically, significant differences were observed between traumatic and sinus zones at the time of surgery and after 60 days respectively (P ≤ 0.05). For each group, a significant decrease in density was observed with the following variables (male, age of 18-40 years, sinus zone, and implant diameter of 4.1 mm). The survival rate was 83.8% after 60 days. Implant surface modification has no significant effect on bone mineral density after a short period of time in the sinus zone. Early loading of the prosthesis can be performed in the traumatic zone only.
Collapse
|
13
|
Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18136994. [PMID: 34208849 PMCID: PMC8297224 DOI: 10.3390/ijerph18136994] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 06/25/2021] [Accepted: 06/27/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND This study aims to evaluate whether there is a correlation between implant stability, bone density, vital bone formation and implant diameter and length. METHODS Ninety patients were enrolled in this study. They underwent a socket preservation procedure with allograft or PRF and after 4 months, a total of 90 implants were placed. CBCT scans were assigned prior to implant placement in order to assess the bone density. During the surgical re-entry, a bone biopsy was harvested with a trephine drill. Immediately after implant insertion, the primary stability was measured. The secondary stability was measured 4 months after implant placement. RESULTS Primary stability showed a significant positive linear correlation with bone density (r = 0.471, p < 0.001) as well as with percentage of new bone formation (r = 0.567, p < 0.001). An average significant association of secondary stability with bone density (rs = 0.498, p < 0.001) and percentage of newly formed bone (r = 0.477, p < 0.001) was revealed. The mean values of primary stability in all three implant sizes, regarding the diameter of the implants, were similar (narrow 67.75; standard 66.78; wide 71.21) with no significant difference (p = 0.262). The same tendency was observed for secondary stability (narrow 73.83; standard 75.25; wide 74.93), with no significant difference (p = 0.277). CONCLUSIONS The study revealed a high correlation between primary and secondary implant stability, and bone density, as well as with the percentage of vital bone formation. Implant length and diameter revealed no linear correlation with the implant stability.
Collapse
|
14
|
Cao NJ, Zhu YH, Gao F, Liang C, Wang ZB, Zhang Y, Hao CP, Wang W. Gradient nanostructured titanium stimulates cell responses in vitro and enhances osseointegration in vivo. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:531. [PMID: 33987229 DOI: 10.21037/atm-20-7588] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Background Though titanium (Ti) is widely used as dental materials in the clinic, effective methods to treat Ti for higher surface biological activity still lack. Through Surface mechanical attrition treatment (SMAT) technology we could endow Ti with gradient nanostructured surface (GNS Ti). To investigate the biocompatibility of GNS Ti for its further application in dental implant field, we study the effects of GNS Ti on cell responses in vitro and osseointegration of the implant with surrounding bone tissues in vivo. Methods In this study, GNS Ti was fabricated by SMAT. In vitro experiment, we co-cultured GNS Ti with bone mesenchymal stem cells (BMSCs), surface characterization was detected by transmission electron microscope (TEM). Adhesion, proliferation and differentiation of BMSCs were evaluated by scanning electron microscope (SEM), MTT, flow cytometry (FCM), alkaline phosphatase (ALP) and osteocalcin (OCN) tests. In vivo experiment, the GNS Ti was implanted into the rabbit mandible. Osteogenesis and osseointegration were evaluated by Micro CT, toluidine blue staining, and immunohistochemical staining at 4, 8, and 12 weeks postoperatively. Results Both results showed that compared with the coarse grained (CG) Ti, the GNS Ti stimulated the adhesion, proliferation, and differentiation of BMSCs and improved osteogenesis and osseointegration. Conclusions This study indicates that gradient nanostructured Ti is a promising material for dental implant application.
Collapse
Affiliation(s)
- Nan-Jue Cao
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China.,The Fourth Affiliated Hospital, Zhejiang University School of Medicine, Yiwu, China
| | - Yu-He Zhu
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Fei Gao
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Chen Liang
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Zhen-Bo Wang
- Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, Shenyang, China
| | - Yue Zhang
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Chun-Ping Hao
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| | - Wei Wang
- School and Hospital of Stomatology, China Medical University, Liaoning Provincial Key Laboratory of Oral Diseases, Shenyang, China
| |
Collapse
|
15
|
Hériveaux Y, Nguyen VH, Biwa S, Haïat G. Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface. ULTRASONICS 2020; 108:106223. [PMID: 32771811 DOI: 10.1016/j.ultras.2020.106223] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 06/11/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The determination of the constitutive law of the BII would be of interest in the context of implant acoustical modeling in order to take into account the imperfect characteristics of the BII. The aim of the present study is to propose an analytical effective model describing the interaction between an ultrasonic wave and a rough BII. To do so, a spring model was considered to determine the equivalent stiffness K of the BII. The stiffness contributions related (i) to the partial contact between the bone and the implant and (ii) to the presence of soft tissues at the BII during the process of osseointegration were assessed independently. K was found to be comprised between 1013 and 1017 N/m3 depending on the roughness and osseointegration of the BII. Analytical values of the reflection and transmission coefficients at the BII were derived from values of K. A good agreement with numerical results obtained through finite element simulation was obtained. This model may be used for future finite element bone-implant models to replace the BII conditions.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, Créteil Cedex 94010, France
| | - Shiro Biwa
- Department of Aeronautics and Astronautics, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France.
| |
Collapse
|
16
|
Hériveaux Y, Audoin B, Biateau C, Nguyen VH, Haïat G. Ultrasonic Propagation in a Dental Implant. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1464-1473. [PMID: 32139153 DOI: 10.1016/j.ultrasmedbio.2020.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 12/23/2019] [Accepted: 01/23/2020] [Indexed: 06/10/2023]
Abstract
Ultrasound techniques can be used to characterize and stimulate dental implant osseointegration. However, the interaction between an ultrasonic wave and the implant-bone interface (IBI) remains unclear. This study-combining experimental and numerical approaches-investigates the propagation of an ultrasonic wave in a dental implant by assessing the amplitude of the displacements along the implant axis. An ultrasonic transducer was excited in a transient regime at 10 MHz. Laser interferometric techniques were employed to measure the amplitude of the displacements, which varied 3.2-8.9 nm along the implant axis. The results demonstrated the propagation of a guided wave mode along the implant axis. The velocity of the first arriving signal was equal to 2110 m.s-1, with frequency components lower than 1 MHz, in agreement with numerical results. Investigating guided wave propagation in dental implants should contribute to improved methods for the characterization and stimulation of the IBI.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Bertrand Audoin
- CNRS, Institut de Mécanique et d'Ingénierie, Talence, France
| | | | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| |
Collapse
|
17
|
Evaluation of the effects of topically applied simvastatin on titanium implant osseointegration. J Oral Biol Craniofac Res 2020; 10:149-152. [DOI: 10.1016/j.jobcr.2020.04.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Revised: 02/04/2020] [Accepted: 04/07/2020] [Indexed: 11/23/2022] Open
|
18
|
Kastala VH, Ramoji Rao MV. Comparative evaluation of implant stability in two different implant systems at baseline and 3-4 months intervals using RFA device (OSSTELL ISQ). Indian J Dent Res 2019; 30:678-686. [PMID: 31854356 DOI: 10.4103/ijdr.ijdr_446_17] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Introduction Osseointegration as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows protocol choice on a patient to patient basis and provides enhanced case documentation. The RFA technique provides with clinically relevant information about the state of the implant-bone interface at any stage after implant placement. Aim Evaluation of primary and secondary stability between implants of two different systems by resonance frequency analysis device. Methodology This study was conducted among 17 patients divided into two groups. Group 1 (n = 10) receiving 20 MIS seven implants and Group 2 (n = 7) received 20 Alphadent active implants. The primary implant stability was measured at the time of implant placement and secondary stability is measured at 3-4 months interval using RFA device OSSTELL ISQ. Statistical analysis was performed using paired t test for intra group and independent sample test for intergroup comparisons. Results No statistically significant differences in primary and secondary stabilities were found between the implant systems at either time intervals (P > 0.05). A positive correlation was noticed between mesiodistal stability and implant diameter in MIS seven group (P < 0.05). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant diameter in Alphadent group (P = 0.03). A positive correlation was noticed between mesiodistal, labiolingual stabilities and implant length in Alphadent group (P = 0.03). Conclusion From the present data, it can be concluded that within the limitations of study, implant systems used and their design features showed no significant correlation to implant stability between the groups. More studies are required to assess the effect of implant designs and surface conditions on implant stability on a long-term basis.
Collapse
Affiliation(s)
- Vidya Hiranmayi Kastala
- Department of Periodontics and Implantology, Drs. Sudha and Nageswar Rao Siddhartha Institute of Dental Sciences, Krishna District, Andhra Pradesh, India
| | - Mulpuri Venkata Ramoji Rao
- Department of Periodontics and Implantology, Drs. Sudha and Nageswar Rao Siddhartha Institute of Dental Sciences, Krishna District, Andhra Pradesh, India
| |
Collapse
|
19
|
Hériveaux Y, Nguyen VH, Geiger D, Haïat G. Elastography of the bone-implant interface. Sci Rep 2019; 9:14163. [PMID: 31578440 PMCID: PMC6775155 DOI: 10.1038/s41598-019-50665-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 09/17/2019] [Indexed: 01/04/2023] Open
Abstract
The stress distribution around endosseous implants is an important determinant of the surgical success. However, no method developed so far to determine the implant stability is sensitive to the loading conditions of the bone-implant interface (BII). The objective of this study is to investigate whether a quantitative ultrasound (QUS) technique may be used to retrieve information on compressive stresses applied to the BII. An acousto-mechanical device was conceived to compress 18 trabecular bovine bone samples onto coin-shaped implants and to measure the ultrasonic response of the BII during compression. The biomechanical behavior of the trabecular bone samples was modeled as Neo-Hookean. The reflection coefficient of the BII was shown to decrease as a function of the stress during the elastic compression of the trabecular bone samples and during the collapse of the trabecular network, with an average slope of −4.82 GPa−1. The results may be explained by an increase of the bone-implant contact ratio and by changes of bone structure occurring during compression. The sensitivity of the QUS response of the BII to compressive stresses opens new paths in the elaboration of patient specific decision support systems allowing surgeons to assess implant stability that should be developed in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Didier Geiger
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
20
|
Gao X, Fraulob M, Haïat G. Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 2019; 16:20190259. [PMID: 31362615 PMCID: PMC6685012 DOI: 10.1098/rsif.2019.0259] [Citation(s) in RCA: 109] [Impact Index Per Article: 18.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/01/2019] [Indexed: 01/09/2023] Open
Abstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone-implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Collapse
Affiliation(s)
- Xing Gao
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
- Research Centre for Medical Robotics and Minimally Invasive Surgical Devices, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| |
Collapse
|
21
|
Does the Drilling Technique for Implant Site Preparation Enhance Implant Success in Low-Density Bone? A Systematic Review. IMPLANT DENT 2019; 28:500-509. [PMID: 31205268 DOI: 10.1097/id.0000000000000917] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE The objective of this systematic review was to investigate the possible association between the drilling technique and proper implant integration and survival in areas with low bone density. MATERIALS AND METHODS An electronic search using the MEDLINE/PubMed database was performed including studies published up to April 2018. Animal and clinical studies that evaluated the association between the drilling technique and proper implant integration and survival in low-density bone were included. RESULTS Fifteen studies met the inclusion criteria, including 7 experimental and 8 clinical. Undersized, osteotome, Piezosurgery, and osseodensification drilling were the 4 techniques found in the literature to enhance osseointegration of implants in low-density bone. Owing to the methodological variation, meta-analysis was not performed. The 4 drilling protocols were effective in increasing primary stability, but the long-term outcome is comparable with that of the conventional surgical drilling protocol. CONCLUSION There is weak evidence suggesting that any of the previously mentioned surgical techniques could enhance successful osseointegration and survival of the implants placed in low-density bone.
Collapse
|
22
|
Hériveaux Y, Nguyen VH, Brailovski V, Gorny C, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: Effect of the roughness parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3370. [PMID: 31255165 DOI: 10.1121/1.5109668] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 05/10/2019] [Indexed: 06/09/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The aim of this study is to derive the main determinants of the ultrasonic response of the BII during osseointegration phenomena. The influence of (i) the surface roughness parameters and (ii) the thickness W of a soft tissue layer on the reflection coefficient r of the BII was investigated using a two-dimensional finite element model. When W increases from 0 to 150 μm, r increases from values in the range [0.45; 0.55] to values in the range [0.75; 0.88] according to the roughness parameters. An optimization method was developed to determine the sinusoidal roughness profile leading to the most similar ultrasonic response for all values of W compared to the original profile. The results show that the difference between the ultrasonic responses of the optimal sinusoidal profile and of the original profile was lower to typical experimental errors. This approach provides a better understanding of the ultrasonic response of the BII, which may be used in future numerical simulation realized at the scale of an implant.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vladimir Brailovski
- Department of Mechanical Engineering, École de technologie supérieure, 1100 Notre-Dame Street West, Montreal, Quebec H3C 1K3, Canada
| | - Cyril Gorny
- Laboratoire PIMM (ENSAM, CNRS, CNAM, Hesam Université), 151 Bd de l'Hôpital 75013 Paris (ENSAM), France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
23
|
Rittel D, Dorogoy A, Haïat G, Shemtov-Yona K. Resonant frequency analysis of dental implants. Med Eng Phys 2019; 66:65-74. [PMID: 30837120 DOI: 10.1016/j.medengphy.2019.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 12/14/2018] [Accepted: 02/17/2019] [Indexed: 12/29/2022]
Abstract
Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.
Collapse
Affiliation(s)
- D Rittel
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel.
| | - A Dorogoy
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| | - G Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-échelle, UMR CNRS 8202, 94010 Créteil Cedex, France
| | - K Shemtov-Yona
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| |
Collapse
|
24
|
Liu F, Liu Y, Li X, Wang X, Li D, Chung S, Chen C, Lee IS. Osteogenesis of 3D printed macro-pore size biphasic calcium phosphate scaffold in rabbit calvaria. J Biomater Appl 2019; 33:1168-1177. [PMID: 30665312 DOI: 10.1177/0885328218825177] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
To investigate the osteogenesis of macro-pore sized bone scaffolds, biphasic calcium phosphate scaffolds with accurately controlled macro-pore size (0.8, 1.2, and 1.6 mm) and identical porosity of 70% were fabricated by the 3D printing technology. Eight New Zealand rabbits were selected in the present study, while four 8-mm-diameter calvarial defects were created in each rabbit to place BCP scaffolds with different macro-pore size. The harvested specimens of four and eight weeks were used to evaluate the bone forming ability by micro CT and histological examination. All 3D-printed BCP scaffolds exhibited excellent mechanical properties and had better bone-forming ability than the control at both four and eight weeks. Among them, scaffold with 0.8 mm pore size was superior for initial bone formation and maturation, resulting in the highest value of total bone formation.
Collapse
Affiliation(s)
- Fan Liu
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China.,3 Department of Pulmonary and Critical Care Medicine, The First Affiliated Hospital, China Medical University, Shenyang, China
| | - Yi Liu
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China
| | - Xinyu Li
- 2 Department of Tissue Engineering, School of Fundamental Sciences, China Medical University, Shenyang, China
| | - Xiaohong Wang
- 1 Department of Orthodontics, School of Stomatology, China Medical University, Shenyang, China
| | - Danni Li
- 4 Department of Medical Oncology, The First Affiliated Hospital, China Medical University, Shenyang, China
| | - SungMin Chung
- 5 Biomaterials R&D Center, GENOSS Co., Ltd., Suwon, Republic of Korea
| | - Cen Chen
- 6 College of Life Sciences, Zhejiang Sci-Tech University, Hangzhou, China
| | - In-Seop Lee
- 7 College of Materials and Textiles, Zhejiang Sci-Tech University, Hangzhou, China.,8 Institute of Natural Sciences, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
25
|
Bioactive Sphene-Based Ceramic Coatings on cpTi Substrates for Dental Implants: An In Vitro Study. MATERIALS 2018; 11:ma11112234. [PMID: 30424012 PMCID: PMC6267351 DOI: 10.3390/ma11112234] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Revised: 10/26/2018] [Accepted: 11/05/2018] [Indexed: 01/08/2023]
Abstract
Titanium implant surface modifications have been widely investigated to favor the process of osseointegration. The present work aimed to evaluate the effect of sphene (CaTiSiO5) biocoating, on titanium substrates, on the in vitro osteogenic differentiation of Human Adipose-Derived Stem Cells (hADSCs). Sphene bioceramic coatings were prepared using preceramic polymers and nano-sized active fillers and deposited by spray coating. Scanning Electron Microscopy (SEM) analysis, surface roughness measurements and X-ray diffraction analysis were performed. The chemical stability of the coatings in Tris-HCl solution was investigated. In vitro studies were performed by means of proliferation test of hADSCs seeded on coated and uncoated samples after 21 days. Methyl Thiazolyl-Tetrazolium (MTT) test and immunofluorescent staining with phalloidin confirmed the in vitro biocompatibility of both substrates. In vitro osteogenic differentiation of the cells was evaluated using Alizarin Red S staining and quantification assay and real-time PCR (Polymerase Chain Reaction). When hADSCs were cultured in the presence of Osteogenic Differentiation Medium, a significantly higher accumulation of calcium deposits onto the sphene-coated surfaces than on uncoated controls was detected. Osteogenic differentiation on both samples was confirmed by PCR. The proposed coating seems to be promising for dental and orthopedic implants, in terms of composition and deposition technology.
Collapse
|
26
|
Mei S, Dong F, Rahman Khan MS. Effects of Biomineralization on Osseointegration of Pure Titanium Implants in the Mandible of Beagles. J Oral Maxillofac Surg 2018; 76:2104.e1-2104.e10. [PMID: 30006302 DOI: 10.1016/j.joms.2018.06.015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Revised: 06/08/2018] [Accepted: 06/08/2018] [Indexed: 10/14/2022]
Abstract
PURPOSE The purpose of this study was to investigate the effect of a biologically active dental implant surface (treated with sandblasting and acid etching [SLA] followed by immersion in simulated body fluid [SBF]) on osseointegration. MATERIALS AND METHODS We randomly divided 9 healthy adult male beagles (aged 8 months; body weight, 12 kg) into 3 groups: machined, SLA, and SLA-biomineralization (SLA-Bio). Six pure titanium implants (diameter of 3.5 mm and length of 8 mm) were used in the mandible of each dog after observation of the surface morphology, as well as analysis of the composition of the surface elements by scanning electron microscopy-energy dispersive x-ray spectroscopy. At 4, 8, and 12 weeks after implantation, animals were euthanized to collect the mandibles so that we could perform the removal torque test to evaluate the implant stability in bone and histomorphometry to analyze the implant-bone osseointegration. RESULTS Scanning electron microscopy results showed that uniformly distributed sponge-like structures were found on the SLA-treated surface and an apatite layer was observed on the SLA-SBF-treated surface (SLA-Bio group). In the energy dispersive x-ray spectroscopy analysis, the elements titanium, oxygen, carbon, calcium, and phosphorus were found on the surfaces of the SLA-Bio group, whereas titanium was the only element found in the other groups. The removal torque test showed that the peak removal torque values of the 3 groups increased gradually with the passage of time, and the peak removal torque values of the SLA-Bio group were significantly higher than those of the other groups (P < .01) at 4, 8, and 12 weeks after implantation. Histomorphometric analysis showed that osseointegration was being enabled more rapidly in the SLA-Bio group, as well as that the mineral apposition rate and percentage of bone-to-implant contact of the SLA-Bio group were higher than those of the remaining groups at 4, 8, and 12 weeks after implantation (P < .01). CONCLUSIONS Treating titanium implants with SLA-SBF can improve osseointegration as well as increase the interfacial shear strength.
Collapse
Affiliation(s)
- Shuang Mei
- Resident, Department of Oral and Maxillofacial Surgery, Hospital of Stomatology, Hebei Medical University, Shijiazhuang, China
| | - Fusheng Dong
- Professor, Department of Oral and Maxillofacial Surgery, Hospital of Stomatology, Hebei Medical University, Shijiazhuang, China.
| | - Mohammad Sayedur Rahman Khan
- Department of Oral & Maxillofacial Surgery, College of Stomatology, Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
27
|
Hériveaux Y, Nguyen VH, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: A numerical study of the effect of the multiscale roughness. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:488. [PMID: 30075648 DOI: 10.1121/1.5046524] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 06/28/2018] [Indexed: 06/08/2023]
Abstract
Quantitative ultrasound is used to characterize and stimulate osseointegration processes at the bone-implant interface (BII). However, the interaction between an ultrasonic wave and the implant remains poorly understood. This study aims at investigating the sensitivity of the ultrasonic response to the microscopic and macroscopic properties of the BII and to osseointegration processes. The reflection coefficient R of the BII was modeled for different frequencies using a two-dimensional finite element model. The implant surface roughness was modeled by a sinusoidal function with varying amplitude h and spatial frequency L. A soft tissue layer of thickness W was considered between bone tissue and the implant in order to model non-mineralized fibrous tissue. For microscopic roughness, R is shown to increase from around 0.55 until 0.9 when kW increases from 0 to 1 and to be constant for kW > 1, where k is the wavenumber in the implant. These results allow us to show that R depends on the properties of bone tissue located at a distance comprised between 1 and 25 μm from the implant surface. For macroscopic roughness, R is highly dependent on h and this dependence may be explained by phase cancellation and multiple scattering effects for high roughness parameters.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
28
|
Vayron R, Nguyen VH, Lecuelle B, Haiat G. Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis. Clin Implant Dent Relat Res 2018; 20:470-478. [PMID: 29770562 DOI: 10.1111/cid.12622] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 02/22/2018] [Accepted: 04/17/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Resonance frequency analyses and quantitative ultrasound methods have been suggested to assess dental implant primary stability. PURPOSE The purpose of this study was to compare the results obtained using these two techniques applied to the same dental implants inserted in various bone phantoms. MATERIALS AND METHODS Different values of trabecular bone density and cortical thickness were considered to assess the effect of bone quality on the respective indicators (UI and ISQ). The effect of the implant insertion depth and of the final drill diameter was also investigated. RESULTS ISQ values increase and UI values decrease as a function of trabecular density, cortical thickness and the screwing of the implant. When the implant diameter varies, the UI values are significantly different for all final drill diameters (except for two), while the ISQ values are similar for all final drill diameters lower than 3.2 mm and higher than 3.3 mm. The error on the estimation of parameters with the QUS device is between 4 and 8 times lower compared to that made with the RFA technique. CONCLUSIONS The results show that ultrasound technique provides a better estimation of different parameters related to the implant stability compared to the RFA technique.
Collapse
Affiliation(s)
- Romain Vayron
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Vu-Hieu Nguyen
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Benoît Lecuelle
- Centre de Recherche BioMédicale, Ecole Nationale Vétérinaire d'Alfort, 7 Avenue du Général de Gaulle, 94700 Maisons-Alfort, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| |
Collapse
|
29
|
Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration. SENSORS 2018; 18:s18051397. [PMID: 29724028 PMCID: PMC5982662 DOI: 10.3390/s18051397] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 04/09/2018] [Accepted: 04/20/2018] [Indexed: 12/31/2022]
Abstract
Dental implants are widely used in the clinic. However, there remain risks of failure, which depend on the implant stability. The aim of this paper is to compare two methods based on resonance frequency analysis (RFA) and on quantitative ultrasound (QUS) and that aim at assessing implant stability. Eighty-one identical dental implants were inserted in the iliac crests of 11 sheep. The QUS and RFA measurements were realized after different healing times (0, 5, 7, and 15 weeks). The results obtained with the QUS (respectively RFA) method were significantly different when comparing two consecutive healing time for 97% (respectively, 18%) of the implants. The error made on the estimation of the healing time when analyzing the results obtained with the QUS technique was around 10 times lower than that made when using the RFA technique. The results corresponding to the dependence of the ISQ versus healing time were significantly different when comparing two directions of RFA measurement. The results show that the QUS method allows a more accurate determination of the evolution of dental implant stability when compared to the RFA method. This study paves the way towards the development of a medical device, thus providing a decision support system to dental surgeons.
Collapse
|
30
|
Falisi G, Severino M, Rastelli C, Bernardi S, Caruso S, Galli M, Lamazza L, Di Paolo C. The effects of surgical preparation techniques and implant macro-geometry on primary stability: An in vitro study. Med Oral Patol Oral Cir Bucal 2017; 22:e201-e206. [PMID: 28160577 PMCID: PMC5359712 DOI: 10.4317/medoral.21286] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Accepted: 01/12/2017] [Indexed: 01/16/2023] Open
Abstract
Background The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure.
The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. Material and Methods 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implant positioning. On each rib, 5 implant sites (one for each technique) were prepared. Successively, 50 conical implants (Tekka Global D) were inserted and measured with the resonance frequency to evaluate the primary stability. Data collected were analyzed by analysis of variance (ANOVA) to test whether the Implant Stability Quotient (ISQ) values of the five techniques were significantly different. Results The results showed that no significant differences among the ISQ values of the five techniques used were found. Also, no significant differences in the macro-geometry of the two types of compared implants were observed. However, the macro-geometry of Tekka implants, characterized by a double condensing thread, seems to provide greater ISQ values than those of single thread implants when using the same technique. Conclusions In light of these preliminary data, it is conceivable that in cases of reduced stability, such as those occurring with a type IV bone, all means ameliorating the primary stability and accelerating the osseointegration can be utilized. Key words:Implant primary stability, resonance frequency analysis, implant site preparation.
Collapse
Affiliation(s)
- G Falisi
- Department of Life, Health, and Environmental Sciences, School of Dentistry, University of L'Aquila, Piazzale Salvatore Tommasi 1, 67100 Coppito (AQ), L'Aquila, Italy,
| | | | | | | | | | | | | | | |
Collapse
|
31
|
Veronesi F, Giavaresi G, Fini M, Longo G, Ioannidu CA, Scotto d'Abusco A, Superti F, Panzini G, Misiano C, Palattella A, Selleri P, Di Girolamo N, Garbarino V, Politi L, Scandurra R. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 70:264-271. [DOI: 10.1016/j.msec.2016.08.076] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 07/26/2016] [Accepted: 08/29/2016] [Indexed: 01/02/2023]
|
32
|
Tasat DR, Bruno ME, Domingo M, Gurman P, Auciello O, Paparella ML, Evelson P, Guglielmotti MB, Olmedo DG. Biokinetics and tissue response to ultrananocrystalline diamond nanoparticles employed as coating for biomedical devices. J Biomed Mater Res B Appl Biomater 2016; 105:2408-2415. [DOI: 10.1002/jbm.b.33777] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 07/12/2016] [Accepted: 08/14/2016] [Indexed: 02/02/2023]
Affiliation(s)
- Deborah R. Tasat
- School of Science and Technology; National University of San Martin; Buenos Aires Argentina
- Department of Histology and Embryology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Marcos E. Bruno
- School of Science and Technology; National University of San Martin; Buenos Aires Argentina
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Mariela Domingo
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- Research Fellow of the National Inter-university Council; Buenos Aires Argentina
| | - Pablo Gurman
- Department of Materials Science and Engineering; University of Texas-Dallas; Richardson Texas United States of America
| | - Orlando Auciello
- Departments of Materials Science and Engineering and Biomedical Engineering; University of Texas-Dallas; Richardson Texas United States of America
| | - María L. Paparella
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
| | - Pablo Evelson
- General and Inorganic Chemistry Division; School of Pharmacy and Biochemistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| | - María B. Guglielmotti
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| | - Daniel G. Olmedo
- Department of Oral Pathology; School of Dentistry, University of Buenos Aires; Buenos Aires Argentina
- National Research Council (CONICET); Buenos Aires Argentina
| |
Collapse
|
33
|
Vayron R, Nguyen VH, Bosc R, Naili S, Haïat G. Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:773-780. [PMID: 26936559 DOI: 10.1121/1.4941452] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Dental implant stability is an important determinant of the surgical success. Quantitative ultrasound (QUS) techniques can be used to assess such properties using the implant acting as a waveguide. However, the interaction between an ultrasonic wave and the implant remains poorly understood. The aim of this study is to investigate the sensitivity of the ultrasonic response to the quality and quantity of bone tissue in contact with the implant surface. The 10 MHz ultrasonic response of an implant used in clinical practice was simulated using an axisymmetric three-dimensional finite element model, which was validated experimentally. The amplitude of the echographic response of the implant increases when the depth of a liquid layer located at the implant interface increases. The results show the sensitivity of the QUS technique to the amount of bone in contact with the implant. The quality of bone tissue around the implant is varied by modifying the bone biomechanical properties by 20%. The amplitude of the implant echographic response decreases when bone quality increases, which corresponds to bone healing. In all cases, the amplitude of the implant response decreased when the dental implant stability increased, which is consistent with the experimental results.
Collapse
Affiliation(s)
- Romain Vayron
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Romain Bosc
- Université Paris-Est, INSERM U955, Equipe 10, 8 rue du Général Sarrail, 94010 Créteil Cedex, France
| | - Salah Naili
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
34
|
Effect of sustained release of rhBMP-2 from dried and wet hyaluronic acid hydrogel carriers compared with direct dip coating of rhBMP-2 on peri-implant osteogenesis of dental implants in canine mandibles. J Craniomaxillofac Surg 2015; 44:116-25. [PMID: 26732636 DOI: 10.1016/j.jcms.2015.11.018] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Revised: 10/19/2015] [Accepted: 11/25/2015] [Indexed: 12/13/2022] Open
Abstract
Hyaluronic acid (HA) hydrogel has been used as a carrier of recombinant human bone morphogenetic protein (rhBMP)-2 for sustained delivery. To enhance peri-implant osteogenesis, a dried coating of rhBMP-2 HA hydrogel (BMP-HAH) on dental implants was designed; this approach provides the advantage of omitting in situ preparation of wet HA hydrogel. Sustained release of rhBMP-2 was more efficient for dried hydrogel over wet hydrogel. For both types, the released rhBMP-2 consistently led to enhanced alkaline phosphatase activity and osterix expression in human mesenchymal stromal cells. Histomorphometric analysis 4 weeks after placement of a dental implant in canine mandibles showed that the dried coating of BMP-HAH (10 μg/ml, n = 6) resulted in a significantly greater bone area (BA) than the wet BMP-HAH (10 μg/ml, n = 6) (p = 0.006) and implants without any coating (n = 6) (p = 0.022), while simple dip coating with rhBMP-2 (10 μg/ml, n = 6) resulted in significantly greater BA than the other three groups (p < 0.0005). Bone-to-implant contact (BIC) was significantly different only between the dried and wet coating of BMP-HAH (p = 0.014). Our results suggest that a simple dip coating of rhBMP-2 is more effective for increased peri-implant osteogenesis compared to a coating of BMP-HAH with sustained release.
Collapse
|
35
|
Harboe K, Ellingsen CL, Sudmann E, Gjerdet NR, Søreide K, Indrekvam K. Can bone apposition predict the retention force of a femoral stem? An experimental weight-bearing hip-implant model in goats. BMC Musculoskelet Disord 2015; 16:102. [PMID: 25927813 PMCID: PMC4423176 DOI: 10.1186/s12891-015-0560-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2014] [Accepted: 04/21/2015] [Indexed: 11/24/2022] Open
Abstract
Background The increasing incidence of prosthesis revision surgery in the Western world has led to an increased focus on the capacity for stem removal. We previously reported on a femoral stem implanted in goats with an approximate 15% reduction in retention force by drilling longitudinally orientated grooves on the side of the stem. In this current study, we aimed to histologically evaluate the bony apposition towards this stem and correlate this apposition with the pullout force. Methods We analyzed the femora of 22 goats after stem removal. All stems remained in place for 6 months, and the goats were allowed regular loading of the hip during this time. For histological evaluation, all femora were immersed in EDTA and decalcified until sufficiently soft for standard technique preparation. We evaluated bone apposition, the presence of foreign particle debris and other factors. The apposition was evaluated with a scoring system based on semi-quantitative bone apposition in four quadrants. Kappa statistics were calculated for the score. We correlated the retention force with the amount of bone apposition. Results The stem drilling was the only significant factor influencing the retention force (p = 0.020). The bone apposition Kappa score comparing poor and good apposition scores was fair (κ = 0.4, 95% CI 0.00–0.88). Signs of foreign body reaction were noted in 5 of 22 goats. Conclusions Based on the current findings in an experimental goat model, it appears that the effect of drilling tissue/bone out of the longitudinal grooves has a more significant impact on the retention force required to remove the stem than the amount of bone apposition outside the stem grooves. This observation may be further explored in the research of stem designs that are potentially easier to remove.
Collapse
Affiliation(s)
- Knut Harboe
- Department of Orthopedic Surgery, Stavanger University Hospital, P.O. Box 8100, Stavanger, 4068, Norway. .,Department of Clinical Medicine, University of Bergen, Bergen, Norway.
| | | | - Einar Sudmann
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.
| | - Nils Roar Gjerdet
- Department of Clinical Dentistry, Biomaterials, University of Bergen, Bergen, Norway.
| | - Kjetil Søreide
- Department of Clinical Medicine, University of Bergen, Bergen, Norway. .,Department of Gastrointestinal Surgery, Stavanger University Hospital, Stavanger, Norway.
| | - Kari Indrekvam
- Department of Clinical Medicine, University of Bergen, Bergen, Norway. .,Kysthospitalet in Hagevik, Clinic of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.
| |
Collapse
|
36
|
Anitua E, Piñas L, Murias A, Prado R, Tejero R. Effects of calcium ions on titanium surfaces for bone regeneration. Colloids Surf B Biointerfaces 2015; 130:173-81. [PMID: 25886795 DOI: 10.1016/j.colsurfb.2015.04.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2015] [Revised: 04/01/2015] [Accepted: 04/02/2015] [Indexed: 01/21/2023]
Abstract
The chemistry and topography of implant surfaces are of paramount importance for the successful tissue integration of load-bearing dental and orthopedic implants. Here we evaluate in vitro and in vivo titanium implant surfaces modified with calcium ions (Ca(2+) surfaces). Calcium ions produce a durable chemical and nano-topographical modification of the titanium oxide interface. Time of flight secondary ion mass spectrometry examination of the outermost surface composition, shows that calcium ions in Ca(2+) surfaces effectively prevent adventitious hydrocarbon passivation of the oxide layer. In aqueous solutions Ca(2+) surfaces release within the first minute, 2/3 of the total measured Ca(2+), the rest is released over the following 85 days. Additionally, Ca(2+) surfaces significantly increase human fetal osteoblasts-like cell adhesion, proliferation and differentiation, as measured by the autocrine synthesis of osteopontin. Relevant for clinical application, after 12 weeks of healing in sheep tibia, microcomputer tomography and histomorphometric analysis show that Ca(2+) surfaces develop significantly more bone contacts and higher bone density in the 1mm region around the implant. Consequently, titanium implants modified with calcium ions represent a valuable tool to improve endosseous integration in the clinical practice.
Collapse
Affiliation(s)
- Eduardo Anitua
- Private Practice in Implantology and Oral Rehabilitation, C/ José María Cagigal, 19, 01007 Vitoria-Gasteiz, Spain; Biotechnology Institute BTI ImasD, C/ Jacinto Quincoces, 39, 01007 Vitoria-Gasteiz, Spain
| | - Laura Piñas
- Private Practice in Implantology and Oral Rehabilitation, C/ José María Cagigal, 19, 01007 Vitoria-Gasteiz, Spain
| | - Alia Murias
- Private Practice in Implantology and Oral Rehabilitation, C/ José María Cagigal, 19, 01007 Vitoria-Gasteiz, Spain
| | - Roberto Prado
- Biotechnology Institute BTI ImasD, C/ Jacinto Quincoces, 39, 01007 Vitoria-Gasteiz, Spain
| | - Ricardo Tejero
- Biotechnology Institute BTI ImasD, C/ Leonardo da Vinci, 14B, 01510 Miñano, Spain; Department of Biochemistry and Molecular Biology, University of the Basque Country, 48940 Leioa, Spain.
| |
Collapse
|
37
|
Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment. Biomech Model Mechanobiol 2015; 14:1021-32. [PMID: 25619479 DOI: 10.1007/s10237-015-0651-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Accepted: 01/10/2015] [Indexed: 12/31/2022]
Abstract
Dental implant stability, which is an important parameter for the surgical outcome, can now be assessed using quantitative ultrasound. However, the acoustical propagation in dental implants remains poorly understood. The objective of this numerical study was to understand the propagation phenomena of ultrasonic waves in cylindrically shaped prototype dental implants and to investigate the sensitivity of the ultrasonic response to the surrounding bone quantity and quality. The 10-MHz ultrasonic response of the implant was calculated using an axisymetric 3D finite element model, which was validated by comparison with results obtained experimentally and using a 2D finite difference numerical model. The results show that the implant ultrasonic response changes significantly when a liquid layer is located at the implant interface compared to the case of an interface fully bounded with bone tissue. A dedicated model based on experimental measurements was developed in order to account for the evolution of the bone biomechanical properties at the implant interface. The effect of a gradient of material properties on the implant ultrasonic response is determined. Based on the reproducibility of the measurement, the results indicate that the device should be sensitive to the effects of a healing duration of less than one week. In all cases, the amplitude of the implant response is shown to decrease when the dental implant primary and secondary stability increase, which is consistent with the experimental results. This study paves the way for the development of a quantitative ultrasound method to evaluate dental implant stability.
Collapse
|
38
|
Bianchi M, Boi M, Sartori M, Giavaresi G, Lopomo N, Fini M, Dediu A, Tampieri A, Marcacci M, Russo A. Nanomechanical mapping of bone tissue regenerated by magnetic scaffolds. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2015; 26:5363. [PMID: 25578711 DOI: 10.1007/s10856-014-5363-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Accepted: 08/06/2014] [Indexed: 06/04/2023]
Abstract
Nanoindentation can provide new insights on the maturity stage of regenerating bone. The aim of the present study was the evaluation of the nanomechanical properties of newly-formed bone tissue at 4 weeks from the implantation of permanent magnets and magnetic scaffolds in the trabecular bone of rabbit femoral condyles. Three different groups have been investigated: MAG-A (NdFeB magnet + apatite/collagen scaffold with magnetic nanoparticles directly nucleated on the collagen fibers during scaffold synthesis); MAG-B (NdFeB magnet + apatite/collagen scaffold later infiltrated with magnetic nanoparticles) and MAG (NdFeB magnet). The mechanical properties of different-maturity bone tissues, i.e. newly-formed immature, newly-formed mature and native trabecular bone have been evaluated for the three groups. Contingent correlations between elastic modulus and hardness of immature, mature and native bone have been examined and discussed, as well as the efficacy of the adopted regeneration method in terms of "mechanical gap" between newly-formed and native bone tissue. The results showed that MAG-B group provided regenerated bone tissue with mechanical properties closer to that of native bone compared to MAG-A or MAG groups after 4 weeks from implantation. Further, whereas the mechanical properties of newly-formed immature and mature bone were found to be fairly good correlated, no correlation was detected between immature or mature bone and native bone. The reported results evidence the efficacy of nanoindentation tests for the investigation of the maturity of newly-formed bone not accessible through conventional analyses.
Collapse
Affiliation(s)
- Michele Bianchi
- Laboratory of Nano-Biotechnologies (NaBi), Rizzoli Orthopaedic Institute, Via Gobetti 1/10, Bologna, 40136, Italy,
| | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Ultrasonic evaluation of dental implant osseointegration. J Biomech 2014; 47:3562-8. [PMID: 25262877 DOI: 10.1016/j.jbiomech.2014.07.011] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 07/08/2014] [Accepted: 07/13/2014] [Indexed: 01/22/2023]
Abstract
Dental implants are widely used for oral rehabilitation. However, there remain risks of failure which are difficult to anticipate and depend on the implant osseointegration. The objective of this in vivo study is to determine the variation of the echographic ultrasonic response of a dental implant to bone healing around the implant interface. Twenty one dental implants were inserted in the femur of seven New Zealand white rabbits. Two animals were sacrificed after a healing duration of two weeks, three animals after six weeks and six animals after eleven weeks. The 10 MHz ultrasonic response of the implant was measured just after the implantation using a dedicated device positioned at the emerging surface of each dental implant. The measurements were realized again before the sacrifice with the same device. An indicator I˜ was derived based on the amplitude of the rf signal obtained for each configuration. The bone-Implant Contact (BIC) ratio was determined by histological analyses. The average value of the relative variation of the indicator I˜ obtained after initial surgery and after the corresponding healing period varies between 7% and 40%. A Kruskal-Wallis test (p<0.01) revealed a significant decrease of the value of the indicator I˜ as function of healing time. The indicator I˜ was significantly correlated (R(2)=0.45) with the BIC ratio. The results show that the ultrasonic response of a dental implant varies significantly as a function of healing time, which paves the way for the development of a new quantitative ultrasound (QUS) method in oral implantology.
Collapse
|
40
|
Javed F, Ahmed HB, Crespi R, Romanos GE. Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation. Interv Med Appl Sci 2013; 5:162-7. [PMID: 24381734 DOI: 10.1556/imas.5.2013.4.3] [Citation(s) in RCA: 150] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2013] [Revised: 09/29/2013] [Accepted: 09/30/2013] [Indexed: 11/19/2022] Open
Abstract
A secure implant primary (mechanical) stability is positively associated with a successful implant integration and long-term successful clinical outcome. Therefore, it is essential to assess the initial stability at different time-points to ensure a successful osseointegration. The present study critically reviews the factors that may play a role in achieving a successful initial stability in dental implants. Databases were searched from 1983 up to and including October 2013 using different combinations of various keywords. Bone quality and quantity, implant geometry, and surgical technique adopted may significantly influence primary stability and overall success rate of dental implants.
Collapse
|
41
|
Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, Haiat G. Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties. J Biomech 2013; 47:3-13. [PMID: 24268798 DOI: 10.1016/j.jbiomech.2013.09.021] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 09/18/2013] [Accepted: 09/24/2013] [Indexed: 12/19/2022]
Abstract
Dental implants are now widely used for the replacement of missing teeth in fully or partially edentulous patients and for cranial reconstructions. However, risks of failure, which may have dramatic consequences, are still experienced and remain difficult to anticipate. The stability of biomaterials inserted in bone tissue depends on multiscale phenomena of biomechanical (bone-implant interlocking) and of biological (mechanotransduction) natures. The objective of this review is to provide an overview of the biomechanical behavior of the bone-dental implant interface as a function of its environment by considering in silico, ex vivo and in vivo studies including animal models as well as clinical studies. The biomechanical determinants of osseointegration phenomena are related to bone remodeling in the vicinity of the implants (adaptation of the bone structure to accommodate the presence of a biomaterial). Aspects related to the description of the interface and to its space-time multiscale nature will first be reviewed. Then, the various approaches used in the literature to measure implant stability and the bone-implant interface properties in vitro and in vivo will be described. Quantitative ultrasound methods are promising because they are cheap, non invasive and because of their lower spatial resolution around the implant compared to other biomechanical approaches.
Collapse
Affiliation(s)
- Vincent Mathieu
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Romain Vayron
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Gilles Richard
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Grégory Lambert
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Salah Naili
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Jean-Paul Meningaud
- Service de Chirurgie Plastique, Reconstructrice et Esthétique, CHU H. Mondor, 94017 Créteil cedex, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France.
| |
Collapse
|
42
|
Variation of the ultrasonic response of a dental implant embedded in tricalcium silicate-based cement under cyclic loading. J Biomech 2013; 46:1162-8. [DOI: 10.1016/j.jbiomech.2013.01.003] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2012] [Revised: 12/30/2012] [Accepted: 01/01/2013] [Indexed: 11/19/2022]
|
43
|
Vayron R, Barthel E, Mathieu V, Soffer E, Anagnostou F, Haiat G. Nanoindentation measurements of biomechanical properties in mature and newly formed bone tissue surrounding an implant. J Biomech Eng 2012; 134:021007. [PMID: 22482674 DOI: 10.1115/1.4005981] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The characterization of the biomechanical properties of newly formed bone tissue around implants is important to understand the osseointegration process. The objective of this study is to investigate the evolution of the hardness and indentation modulus of newly formed bone tissue as a function of healing time. To do so, a nanoindentation device is employed following a multimodality approach using histological analysis. Coin-shaped implants were placed in vivo at a distance of 200 μm from the cortical bone surface, leading to an initially empty cavity of 200 μm * 4.4 mm. Three New Zealand White rabbits were sacrificed after 4, 7, and 13 weeks of healing time. The bone samples were embedded and analyzed using histological analyses, allowing to distinguish mature and newly formed bone tissue. The bone mechanical properties were then measured in mature and newly formed bone tissue. The results are within the range of hardness and apparent Young's modulus values reported in previous literature. One-way ANOVA test revealed a significant effect of healing time on the indentation modulus (p < 0.001, F = 111.24) and hardness (p < 0.02, F = 3.47) of bone tissue. A Tukey-Kramer analysis revealed that the biomechanical properties of newly formed bone tissue (4 weeks) were significantly different from those of mature bone tissue. The comparison with the results obtained in Mathieu et al. (2011, "Micro-Brillouin Scattering Measurements in Mature and Newly Formed Bone Tissue Surrounding an Implant," J. Biomech. Eng., 133, 021006). shows that bone mass density increases by approximately 13.5% between newly formed bone (7 weeks) and mature bone tissue.
Collapse
Affiliation(s)
- Romain Vayron
- Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, CNRS, Université Paris Est, Créteil 94010, France
| | | | | | | | | | | |
Collapse
|
44
|
Harder S, Quabius ES, Ossenkop L, Mehl C, Kern M. Surface contamination of dental implants assessed by gene expression analysis in a whole-blood in vitro assay: a preliminary study. J Clin Periodontol 2012; 39:987-94. [PMID: 22862842 DOI: 10.1111/j.1600-051x.2012.01929.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/19/2012] [Indexed: 11/28/2022]
Abstract
AIM We aimed at evaluating pyrogen contamination of dental implants made of titanium and zirconia by using gene expression analysis in a whole-blood in vitro assay. MATERIAL AND METHODS Titanium and zirconia implants (five each) were incubated in human whole blood. Samples were assayed for gene expression levels of toll-like receptor 4 (TLR4), TLR9, interleukin (IL)-1β, nuclear factor 'kappa-light-chain-enhancer' of activated B-cells (NF-kB), tumour necrosis factor (TNF)-α, and Fas-associated protein with death domain (FADD) as indicators of surface contamination resulting in lipopolysaccharides (LPS)-stimulated TLR- or TNF-mediated immune responses. Gene expression was assayed using real-time quantitative polymerase chain reaction (RT-qPCR). Non-stimulated blood from the same donor served as a negative control, and blood stimulated with LPS served as a positive control. After dry-heat treatment with dry heat, all implants were re-analysed as described above. RESULTS Both implant systems contained surface contaminants evoking a pro-inflammatory response similar to that induced by LPS. After dry-heat treatment, gene expression was significantly decreased to levels similar to those of negative control samples. CONCLUSIONS The results demonstrated LPS-like surface-bound contaminants in both tested implant systems. Depyrogenation with dry heat seems to be an effective means of reducing such contamination in dental implants.
Collapse
Affiliation(s)
- Sönke Harder
- Department of Prosthodontics, Propaedeutics and Dental Materials, Christian-Albrechts University, Kiel, Germany.
| | | | | | | | | |
Collapse
|
45
|
Orsini E, Salgarello S, Martini D, Bacchelli B, Quaranta M, Pisoni L, Bellei E, Joechler M, Ottani V. Early healing events around titanium implant devices with different surface microtopography: a pilot study in an in vivo rabbit model. ScientificWorldJournal 2012; 2012:349842. [PMID: 22545015 PMCID: PMC3322675 DOI: 10.1100/2012/349842] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2011] [Accepted: 10/21/2011] [Indexed: 11/17/2022] Open
Abstract
In the present pilot study, the authors morphologically investigated sandblasted, acid-etched surfaces (SLA) at very early experimental times. The tested devices were titanium plate-like implants with flattened wide lateral sides and jagged narrow sides. Because of these implant shape and placement site, the device gained a firm mechanical stability but the largest portion of the implant surface lacked direct contact with host bone and faced a wide peri-implant space rich in marrow tissue, intentionally created in order to study the interfacial interaction between metal surface and biological microenvironment. The insertion of titanium devices into the proximal tibia elicited a sequence of healing events. Newly formed bone proceeded through an early distance osteogenesis, common to both surfaces, and a delayed contact osteogenesis which seemed to follow different patterns at the two surfaces. In fact, SLA devices showed a more osteoconductive behavior retaining a less dense blood clot, which might be earlier and more easily replaced, and leading to a surface-conditioning layer which promotes osteogenic cell differentiation and appositional new bone deposition at the titanium surface. This model system is expected to provide a starting point for further investigations which clarify the early cellular and biomolecular events occurring at the metal surface.
Collapse
Affiliation(s)
- Ester Orsini
- Department of Human Anatomical Sciences and Physiopathology of Locomotor Apparatus, Human Anatomy Section, University of Bologna, via Irnerio 48, 40126 Bologna, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Mathieu V, Vayron R, Soffer E, Anagnostou F, Haïat G. Influence of healing time on the ultrasonic response of the bone-implant interface. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:611-618. [PMID: 22341053 DOI: 10.1016/j.ultrasmedbio.2011.12.014] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2011] [Revised: 12/13/2011] [Accepted: 12/16/2011] [Indexed: 05/31/2023]
Abstract
The aim of the present study is to investigate the effect of bone healing on the ultrasonic response of coin-shaped titanium implants inserted in rabbit tibiae. The ultrasound response of the interface was measured in vitro at 15 MHz after 7 and 13 weeks of healing time. The average value of the ratio r between the amplitudes of the echo of the bone-implant interface and of the water-implant interface was determined. The bone-implant contact (BIC) was measured by histomorphometry and the degree of mineralisation of bone was estimated qualitatively by histologic staining. The significant decrease of the ultrasonic quantitative indicator r (p = 2.10⁻⁴) vs. healing time (from r = 0.53 to r = 0.49) is explained by (1) the increase of the BIC (from 27% to 69%) and (2) the increase of mineralization of newly formed bone tissue, both phenomena inducing a decrease of the gap of acoustical impedance.
Collapse
Affiliation(s)
- Vincent Mathieu
- CNRS, Université Paris 7, Laboratoire de Biomécanique Biomatériaux Ostéo-Articulaires, UMR CNRS 7052, Paris, France.
| | | | | | | | | |
Collapse
|
47
|
Colombo JS, Satoshi S, Okazaki J, Crean SJ, Sloan AJ, Waddington RJ. In vivo monitoring of the bone healing process around different titanium alloy implant surfaces placed into fresh extraction sockets. J Dent 2012; 40:338-46. [PMID: 22307025 DOI: 10.1016/j.jdent.2012.01.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2011] [Revised: 01/19/2012] [Accepted: 01/20/2012] [Indexed: 10/14/2022] Open
Abstract
OBJECTIVES Increasing surface roughness and coating with tricalcium phosphate of titanium and titanium alloy implants has been proposed to provide better rates of osseointegration. However, how these changes in surface topography and chemistry influence the osseointegration process of immediate implants placed in fresh extraction sockets is unclear. This study investigated the influence of three clinically employed implant surfaces on the early bone healing events in vivo. METHODS Machined smooth implants were milled from grade 5 Ti6Al4V titanium. Surfaces were moderately roughened by grit blasting, which were then coated with tricalcium phosphate. Implants were placed into freshly extracted incisor sockets of mandibles of normal Wistar rats and left for 1, 3 and 9 weeks. Healing bone tissue around the implants was examined by histochemistry and immunocytochemistry to localise PCNA proliferative cells, and osteoblast differentiation markers osteopontin and osteocalcin. Positive synthesising cells were counted using image analysis. RESULTS Histology indicated no differences in the amount or pattern of bone formation within the healing tissue surrounding the different implant surfaces. Bone healing occurred predominantly on exposed bone surfaces (distance osteogenesis) and not on the implant surface (contact osteogenesis). No differences were observed in the number or timing of PCNA, osteopontin and osteocalcin positive cells within the bone healing tissue around each of the implant analysed. CONCLUSION For immediately placed implants, the surface modifications investigated appeared to have little influence on the activity of bone forming cells surrounding the implant, probably due to the high level of distance osteogenesis seen within this scenario. CLINICAL SIGNIFICANCE For immediate placement of implants into fresh extraction sockets, titanium implants with roughened surfaces and coating with tricalcium phosphate have negligible influence in accelerating the early bone healing events of osseointegration.
Collapse
Affiliation(s)
- John S Colombo
- Mineralised Tissue Group, Tissue Engineering and Reparative Dentistry, School of Dentistry, Cardiff University, Heath Park, Cardiff, CF14 4XY, UK
| | | | | | | | | | | |
Collapse
|
48
|
Mathieu V, Vayron R, Barthel E, Dalmas D, Soffer E, Anagnostou F, Haiat G. Mode III cleavage of a coin-shaped titanium implant in bone: effect of friction and crack propagation. J Mech Behav Biomed Mater 2012; 8:194-203. [PMID: 22402166 DOI: 10.1016/j.jmbbm.2011.12.012] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2011] [Revised: 11/14/2011] [Accepted: 12/27/2011] [Indexed: 11/19/2022]
Abstract
Endosseous cementless implants are widely used in orthopaedic, maxillofacial and oral surgery. However, failures are still observed and remain difficult to anticipate as remodelling phenomena at the bone-implant interface are poorly understood. The assessment of the biomechanical strength of the bone-implant interface may improve the understanding of the osseointegration process. An experimental approach based on a mode III cleavage mechanical device aims at understanding the behaviour of a planar bone-implant interface submitted to torsional loading. To do so, coin-shaped titanium implants were inserted on the tibiae of a New Zealand white rabbit for seven weeks. After the sacrifice, mode III cleavage experiments were performed on bone samples. An analytical model was developed to understand the debonding process of the bone-implant interface. The model allowed to assess the values of different parameters related to bone tissue at the vicinity of the implant with the additional assumption that bone adhesion occurs over around 70% of the implant surface, which is confirmed by microscopy images. The approach allows to estimate different quantities related to the bone-implant interface such as: torsional stiffness (around 20.5 N m rad(-1)), shear modulus (around 240 MPa), maximal torsional loading (around 0.056 N.m), mode III fracture energy (around 77.5 N m(-1)) and stress intensity factor (0.27 MPa m(1/2)). This study paves the way for the use of mode III cleavage testing for the investigation of torsional loading strength of the bone-implant interface, which might help for the development and optimization of implant biomaterial, surface treatment and medical treatment investigations.
Collapse
Affiliation(s)
- Vincent Mathieu
- CNRS, Université Paris Diderot, Laboratoire de Biomécanique Biomatériau Ostéo Articulaire, UMR CNRS 7052, 10 avenue de Verdun, Paris, 75010, France
| | | | | | | | | | | | | |
Collapse
|
49
|
Mathieu V, Anagnostou F, Soffer E, Haiat G. Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:4062-4072. [PMID: 21682427 DOI: 10.1121/1.3586788] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Osseointegration of dental implants remains poorly understood. The objective of this numerical study is to understand the propagation phenomena of ultrasonic waves in prototypes cylindrically shaped implants and to investigate the sensitivity of their ultrasonic response to the surrounding bone biomechanical properties. The 10 MHz ultrasonic response of the implant was calculated using a finite difference numerical simulation tool and was compared to rf signals taken from a recent experimental study by Mathieu et al. [Ultrasound Med. Biol. 37, 262-270 (2011a)]. Reflection and mode conversion phenomena were analyzed to understand the origin of the different echoes and the importance of lateral wave propagation was evidenced. The sensitivity of the ultrasonic response of the implant to changes of (i) amount of bone in contact with the implant, (ii) cortical bone thickness, and (iii) surrounding bone material properties, was compared to the reproducibility of the measurements. The results show that, either a change of 1 mm of bone in contact with the implant, or 1.1 mm of cortical thickness or 12% of trabecular bone mass density should be detectable. This study paves the way for the investigation of the use of quantitative ultrasound techniques for the evaluation of bone-implant interface properties and implant stability.
Collapse
Affiliation(s)
- Vincent Mathieu
- CNRS, Université Paris Diderot, Laboratoire de Biomécanique et Biomatériaux Ostéo-Articulaires, UMR CNRS 7052, 10 avenue de Verdun, 75010 Paris, France
| | | | | | | |
Collapse
|
50
|
Mathieu V, Anagnostou F, Soffer E, Haïat G. Ultrasonic evaluation of dental implant biomechanical stability: an in vitro study. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:262-270. [PMID: 21257090 DOI: 10.1016/j.ultrasmedbio.2010.10.008] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/04/2010] [Revised: 09/22/2010] [Accepted: 10/07/2010] [Indexed: 05/30/2023]
Abstract
Dental implants are widely used for oral rehabilitation. However, there remain risks of failure that are difficult to anticipate. The objective of this ex vivo study is to investigate the potentiality of quantitative ultrasound (QUS) to assess the amount of bone in contact with titanium prototype cylindrical implants. Four groups of 10 rabbit femurs each are considered, corresponding to different amounts of bone in contact with the implant. The 10 MHz ultrasonic response of the implant is processed to derive a quantitative indicator I, based on the temporal variation of the signal amplitude. Analysis of variance (ANOVA) (p < 10(-5)) tests revealed a statistical distribution of I significantly correlated with the amount of bone in contact with the cylinders. An analytical model considering the propagation of lateral waves allows the understanding of the physical origin of the echoes. QUS technique may be used to investigate the amount of bone in contact with a cylinder implant.
Collapse
Affiliation(s)
- Vincent Mathieu
- CNRS, Université Paris 7, Laboratoire de Biomécanique Biomatériaux Ostéo Articulaires, UMR CNRS 7052, Paris, France
| | | | | | | |
Collapse
|