1
|
Vecsey-Nagy M, Varga-Szemes A, Schoepf UJ, Tremamunno G, Fink N, Zsarnoczay E, Szilveszter B, Graafen D, Halfmann MC, Vattay B, Boussoussou M, O'Doherty J, Suranyi PS, Maurovich-Horvat P, Emrich T. Ultra-high resolution coronary CT angiography on photon-counting detector CT: bi-centre study on the impact of quantum iterative reconstruction on image quality and accuracy of stenosis measurements. Eur J Radiol 2024; 176:111517. [PMID: 38805884 DOI: 10.1016/j.ejrad.2024.111517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Accepted: 05/17/2024] [Indexed: 05/30/2024]
Abstract
PURPOSE To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.
Collapse
Affiliation(s)
- Milan Vecsey-Nagy
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Heart and Vascular Centre, Semmelweis University, 68. Varosmajor street, Budapest 1122, Hungary
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States.
| | - Giuseppe Tremamunno
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Medical Surgical Sciences and Translational Medicine, Sapienza University of Rome - Sant'Andrea University, Hospital Via di Grottarossa 1035-1039 00189 Rome, Italy
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Radiology, University Hospital, LMU Munich, Marchioninistraße 15, Munich 81377, Germany
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Centre, Semmelweis University, Koranyi Sandor street 2, Budapest 1083, Hungary
| | - Bálint Szilveszter
- Heart and Vascular Centre, Semmelweis University, 68. Varosmajor street, Budapest 1122, Hungary
| | - Dirk Graafen
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, Mainz 55131, Germany
| | - Moritz C Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, Mainz 55131, Germany
| | - Borbála Vattay
- Heart and Vascular Centre, Semmelweis University, 68. Varosmajor street, Budapest 1122, Hungary
| | - Melinda Boussoussou
- Heart and Vascular Centre, Semmelweis University, 68. Varosmajor street, Budapest 1122, Hungary
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Siemens Medical Solutions USA Inc, 40 Liberty Boulevard, Malvern, PA 19355, United States
| | - Pal Spruill Suranyi
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States
| | - Pál Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Centre, Semmelweis University, Koranyi Sandor street 2, Budapest 1083, Hungary
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, United States; Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Langenbeckstraße 1, Mainz 55131, Germany
| |
Collapse
|
2
|
Omaygenc MO, Kadoya Y, Small GR, Chow BJW. Cardiac CT: Competition, complimentary or confounder. J Med Imaging Radiat Sci 2024; 55:S31-S38. [PMID: 38433089 DOI: 10.1016/j.jmir.2024.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 01/17/2024] [Accepted: 01/22/2024] [Indexed: 03/05/2024]
Abstract
Coronary CT angiography (CCTA) has been gradually adopted into clinical practice over the last two decades. CCTA has high diagnostic accuracy, prognostic value, and unique features such as assessment of plaque composition. CCTA-derived functional assessment techniques such as fractional flow reserve and CT perfusion are also available and can increase the diagnostic specificity of the modality. These properties propound CCTA as a competitor of functional testing in diagnosis of obstructive CAD, however, utilizing CCTA in a concomitant fashion to potentiate the performance of the latter can lead to better patient care and may provide more accurate prognostic information. Although multiple diagnostic challenges such as evaluation of calcified segments, stents, and small distal vessels still exist, the technologic developments in hardware as well as growing incorporation of artificial intelligence to daily practice are all set to augment the diagnostic and prognostic role of CCTA in cardiovascular disorders.
Collapse
Affiliation(s)
- Mehmet Onur Omaygenc
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada.
| | - Yoshito Kadoya
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Gary Robert Small
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada
| | - Benjamin Joe Wade Chow
- Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, ON, K1Y 4W7, Canada; Department of Radiology, University of Ottawa, Ottawa, Canada
| |
Collapse
|
3
|
Bieberle M, Papapetrou TN, Lecrivain G, Windisch D, Bieberle A, Wagner M, Hampel U. Simplified Beam Hardening Correction for Ultrafast X-ray CT Imaging of Binary Granular Mixtures. SENSORS (BASEL, SWITZERLAND) 2024; 24:2964. [PMID: 38793819 PMCID: PMC11124780 DOI: 10.3390/s24102964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 04/19/2024] [Accepted: 05/02/2024] [Indexed: 05/26/2024]
Abstract
Ultrafast X-ray computed tomography is an advanced imaging technique for multiphase flows. It has been used with great success for studying gas-liquid as well as gas-solid flows. Here, we apply this technique to analyze density-driven particle segregation in a rotating drum as an exemplary use case for analyzing industrial particle mixing systems. As glass particles are used as the denser of two granular species to be mixed, beam hardening artefacts occur and hamper the data analysis. In the general case of a distribution of arbitrary materials, the inverse problem of image reconstruction with energy-dependent attenuation is often ill-posed. Consequently, commonly known beam hardening correction algorithms are often quite complex. In our case, however, the number of materials is limited. We therefore propose a correction algorithm simplified by taking advantage of the known material properties, and demonstrate its ability to improve image quality and subsequent analyses significantly.
Collapse
Affiliation(s)
- Martina Bieberle
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstr. 400, 01328 Dresden, Germany
| | - Theodoros Nestor Papapetrou
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstr. 400, 01328 Dresden, Germany
- Institute of Power Engineering, TUD Dresden University of Technology, Nöthnitzer Str. 69, 01062 Dresden, Germany
| | - Gregory Lecrivain
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstr. 400, 01328 Dresden, Germany
| | - Dominic Windisch
- Institute of Power Engineering, TUD Dresden University of Technology, Nöthnitzer Str. 69, 01062 Dresden, Germany
| | - André Bieberle
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstr. 400, 01328 Dresden, Germany
| | - Michael Wagner
- Institute of Power Engineering, TUD Dresden University of Technology, Nöthnitzer Str. 69, 01062 Dresden, Germany
| | - Uwe Hampel
- Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstr. 400, 01328 Dresden, Germany
- Institute of Power Engineering, TUD Dresden University of Technology, Nöthnitzer Str. 69, 01062 Dresden, Germany
| |
Collapse
|
4
|
Deneke T, Kutyifa V, Hindricks G, Sommer P, Zeppenfeld K, Carbuccichio C, Pürerfellner H, Heinzel FR, Traykov VB, De Riva M, Pontone G, Lehmkuhl L, Haugaa K. Pre- and post-procedural cardiac imaging (computed tomography and magnetic resonance imaging) in electrophysiology: a clinical consensus statement of the European Heart Rhythm Association and European Association of Cardiovascular Imaging of the European Society of Cardiology. Europace 2024; 26:euae108. [PMID: 38743765 PMCID: PMC11104536 DOI: 10.1093/europace/euae108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 04/11/2024] [Indexed: 05/16/2024] Open
Abstract
Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.
Collapse
Affiliation(s)
- Thomas Deneke
- Clinic for Rhythmology at Klinikum Nürnberg Campus Süd, University Hospital of the Paracelsus Medical University, Nuremberg, Germany
| | | | | | | | - Katja Zeppenfeld
- Department of Cardiology, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| | | | - Helmut Pürerfellner
- Department of Clinical Electrophysiology, Ordensklinikum Linz Elisabethinen, Linz, Austria
| | - Frank R Heinzel
- Städtisches Klinikum Dresden, Department of Cardiology, Angiology and Intensive Care Medicine, Dresden, Germany
| | - Vassil B Traykov
- Department of Invasive Electrophysiology and Cardiac Pacing, Acibadem City Clinic Tokuda Hospital, Sofia, Bulgaria
| | - Marta De Riva
- Department of Cardiology, Leiden University Medical Center (LUMC), Leiden, The Netherlands
| | - Gianluca Pontone
- Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Lukas Lehmkuhl
- Department of Radiology, Heart Center RHÖN-KLINIKUM Campus Bad Neustadt, Germany
| | | |
Collapse
|
5
|
Szczykutowicz TP. Computed Tomography Angiography: Principles and Advances. Radiol Clin North Am 2024; 62:371-383. [PMID: 38553175 DOI: 10.1016/j.rcl.2024.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
This review describes current state-of-the-art computed tomography technology required to address human-physiology-based challenges unique to angiographic imaging. Challenges are based on the need to image a bolus of contrast agent traversing inside rapidly moving structures. This article reviews the latest methods to optimize contrast timing and minimize motion.
Collapse
Affiliation(s)
- Timothy P Szczykutowicz
- University of Wisconsin Madison, 1005 WIMR, 1111 Highland Avenue, Madison, WI 53705, USA. https://twitter.com/Prof_TimStick
| |
Collapse
|
6
|
Catapano F, Lisi C, Savini G, Olivieri M, Figliozzi S, Caracciolo A, Monti L, Francone M. Deep Learning Image Reconstruction Algorithm for CCTA: Image Quality Assessment and Clinical Application. J Comput Assist Tomogr 2024; 48:217-221. [PMID: 37621087 DOI: 10.1097/rct.0000000000001537] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/26/2023]
Abstract
OBJECTIVE The increasing number of coronary computed tomography angiography (CCTA) requests raised concerns about dose exposure. New dose reduction strategies based on artificial intelligence have been proposed to overcome limitations of iterative reconstruction (IR) algorithms. Our prospective study sought to explore the added value of deep-learning image reconstruction (DLIR) in comparison with a hybrid IR algorithm (adaptive statistical iterative reconstruction-veo [ASiR-V]) in CCTA, even in clinical challenging scenarios, as obesity, heavily calcified vessels and coronary stents. METHODS We prospectively included 103 consecutive patients who underwent CCTA. Data sets were reconstructed with ASiR-V and DLIR. For each reconstruction signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) was calculated, and qualitative assessment was made with a four-point Likert scale by two independent and blinded radiologists with different expertise. RESULTS Both SNR and CNR were significantly higher in DLIR (SNR-DLIR median value [interquartile range] of 13.89 [11.06-16.35] and SNR-ASiR-V 25.42 [22.46-32.22], P < 0.001; CNR-DLIR 16.84 [9.83-27.08] vs CNR-ASiR-V 10.09 [5.69-13.5], P < 0.001).Median qualitative score was 4 for DLIR images versus 3 for ASiR-V ( P < 0.001), with a good interreader reliability [intraclass correlation coefficient(2,1)e intraclass correlation coefficient(3,1) 0.60 for DLIR and 0.62 and 0.73 for ASiR-V].In the obese and in the "calcifications and stents" groups, DLIR showed significantly higher values of SNR (24.23 vs 11.11, P < 0.001 and 24.55 vs 14.09, P < 0.001, respectively) and CNR (16.08 vs 8.04, P = 0.008 and 17.31 vs 10.14, P = 0.003) and image quality. CONCLUSIONS Deep-learning image reconstruction in CCTA allows better SNR, CNR, and qualitative assessment than ASiR-V, with an added value in the most challenging clinical scenarios.
Collapse
Affiliation(s)
| | - Costanza Lisi
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
| | - Giovanni Savini
- Neuroradiology Unit, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Marzia Olivieri
- Department of neuroscience, Imaging and Clinical Sciences, "G. D'Annunzio" University of Chieti-Pescara, Chieti, Italy
| | - Stefano Figliozzi
- From the Department of Radiology, IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | - Alessandra Caracciolo
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
| | | | | |
Collapse
|
7
|
Mergen V, Sartoretti T, Cundari G, Serifovic M, Higashigaito K, Allmendinger T, Schmidt B, Flohr T, Manka R, Eberhard M, Alkadhi H. The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT. Invest Radiol 2023; 58:767-774. [PMID: 37222522 DOI: 10.1097/rli.0000000000000987] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
PURPOSE The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT. MATERIALS AND METHODS This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.2 mm. Gantry rotation time was 0.25 seconds. Each scan was reconstructed using both single-source and dual-source data resulting in an image temporal resolution of 125 milliseconds and 66 milliseconds, respectively. The average heart rate and the heart rate variability were recorded. Images were reconstructed with a slice thickness of 0.2 mm, quantum iterative reconstruction strength level 4, and using the Bv64 and Bv72 kernel for patients without and with coronary stents, respectively. For subjective image quality, 2 experienced readers rated motion artifacts and vessel delineation, or in-stent lumen visualization using 5-point discrete visual scales. For objective image quality, signal-to-noise ratio, contrast-to-noise ratio, stent blooming artifacts, and vessel and stent sharpness were quantified. RESULTS Fifteen patients had coronary stents, and 15 patients had no coronary stents. The mean heart rate and heart rate variability during data acquisition were 72 ± 10 beats per minute and 5 ± 6 beats per minute, respectively. Subjective image quality in the right coronary artery, left anterior descending, and circumflex artery was significantly superior in 66 milliseconds reconstructions compared with 125 milliseconds reconstructions for both readers (all P 's < 0.01; interreader agreement, Krippendorff α = 0.84-1.00). Subjective image quality deteriorated significantly at higher heart rates for 125 milliseconds (ρ = 0.21, P < 0.05) but not for 66 milliseconds reconstructions (ρ = 0.11, P = 0.22). No association was found between heart rate variability and image quality for both 125 milliseconds (ρ = 0.09, P = 0.33) and 66 milliseconds reconstructions (ρ = 0.13, P = 0.17), respectively. Signal-to-noise ratio and contrast-to-noise ratio were similar between 66 milliseconds and 125 milliseconds reconstructions (both P 's > 0.05), respectively. Stent blooming artifacts were significantly lower on 66 milliseconds than on 125 milliseconds reconstructions (46.7% ± 10% vs 52.9% ± 8.9%, P < 0.001). Higher sharpness was found in 66 milliseconds than in 125 milliseconds reconstructions both in native coronary arteries (left anterior descending artery: 1031 ± 265 ∆HU/mm vs 819 ± 253 ∆HU/mm, P < 0.01; right coronary artery: 884 ± 352 ∆HU/mm vs 654 ± 377 ∆HU/mm, P < 0.001) and stents (5318 ± 3874 ∆HU/mm vs 4267 ± 3521 ∆HU/mm, P < 0.001). CONCLUSIONS Coronary angiography with PCD-CT in the UHR mode profits considerably from a high temporal resolution, resulting in less motion artifacts, superior vessel delineation and in-stent lumen visualization, less stent blooming artifacts, and superior vessel and stent sharpness.
Collapse
Affiliation(s)
- Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (V.M., T.S., G.C., M.S., K.H., R.M., M.E., H.A.); Department of Radiological, Oncological, and Anatomopathological Sciences, Sapienza University of Rome, Rome, Italy (G.C.); Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany (T.A., B.S., T.F.); and Institute of Radiology, Spitäler fmi AG, Spital Interlaken, Unterseen, Switzerland (M.E.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Poznyak AV, Sukhorukov VN, Eremin II, Nadelyaeva II, Orekhov AN. Diagnostics of atherosclerosis: Overview of the existing methods. Front Cardiovasc Med 2023; 10:1134097. [PMID: 37229223 PMCID: PMC10203409 DOI: 10.3389/fcvm.2023.1134097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Accepted: 04/11/2023] [Indexed: 05/27/2023] Open
Abstract
Atherosclerosis was and remains an extremely common and serious health problem. Since the elderly are most at risk of cardiovascular risk, and the average life expectancy is increasing, the spread of atherosclerosis and its consequences increases as well. One of the features of atherosclerosis is its asymptomaticity. This factor makes it difficult to make a timely diagnosis. This entails the lack of timely treatment and even prevention. To date, in the arsenal of physicians, there is only a limited set of methods to suspect and fully diagnose atherosclerosis. In this review, we have tried to briefly describe the most common and effective methods for diagnosing atherosclerosis.
Collapse
|
9
|
Kusk MW, Stowe J, Hess S, Gerke O, Foley S. Low-cost 3D-printed anthropomorphic cardiac phantom, for computed tomography automatic left ventricle segmentation and volumetry - A pilot study. Radiography (Lond) 2023; 29:131-138. [PMID: 36368249 DOI: 10.1016/j.radi.2022.10.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/04/2022] [Accepted: 10/21/2022] [Indexed: 11/09/2022]
Abstract
INTRODUCTION Accurate cardiac left ventricle (LV) delineation is essential to CT-derived left ventricular ejection fraction (LVEF). To evaluate dose-reduction potential, an anatomically accurate heart phantom, with realistic X-ray attenuation is required. We demonstrated and tested a custom-made phantom using 3D-printing, and examined the influence of image noise on automatically measured LV volumes METHODS: A single coronary CT angiography (CCTA) dataset was segmented and converted to Standard Tessellation Language (STL) mesh, using open-source software. A 3D-printed model, with hollow left heart chambers, was printed and cavities filled with gelatinized contrast media. This was CT-scanned in an anthropomorphic chest phantom, at different exposure conditions. LV and "myocardium" noise and attenuation was measured. LV volume was automatically measured using two different methods. We calculated Spearmans' correlation of LV volume with noise and contrast-noise ratio respectively om 486 scans of the phantom. Source images were compared to one phantom series with similar parameters. This was done using Dice coefficient on LV short-axis segmentations. RESULTS Phantom "Myocardium" and LV attenuation was comparable to measurements on source images. Automatic volume measurement succeeded, with mean volume deviation to patient images less than 2 ml. There was a moderate correlation of volume with CNR, and strong correlation of volume with image noise. With papillary muscles included in LV volume, the correlation was positive, but negative when excluded. Variation of volumes was lowest at 90-100 kVp for both methods in the 486 repeat scans. The Dice coefficient was 0.87, indicating high overlap between the single phantom series and source scan. Cost of 3D-printer and materials was 400 and 30 Euro respectively. CONCLUSION Both anatomically and radiologically the phantom mimicked the source scans closely. LV volumetry was reliably performed with automatic algorithms. IMPLICATIONS FOR PRACTICE Patient-specific cardiac phantoms may be produced at minimal cost and can potentially be used for other anatomies and pathologies. This enables radiographic phantom studies without need for dedicated 3D-labs or expensive commercial phantoms.
Collapse
Affiliation(s)
- M W Kusk
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland; Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Hospital South West Jutland Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, Esbjerg, Denmark.
| | - J Stowe
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
| | - S Hess
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Hospital South West Jutland Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - O Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - S Foley
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
| |
Collapse
|
10
|
Gać P, Cheładze P, Poręba R. The Importance of Cardiac Computed Tomography in the Diagnosis of Caseous Calcification of the Mitral Annulus—Case Reports. Diagnostics (Basel) 2022; 12:diagnostics12030667. [PMID: 35328220 PMCID: PMC8947161 DOI: 10.3390/diagnostics12030667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 03/02/2022] [Accepted: 03/07/2022] [Indexed: 12/01/2022] Open
Abstract
Mitral annular calcification (MAC) is a common pathology of the mitral valve. In rare cases, calcifications occur in the mitral annulus degenerate serous; the caseous calcification of the mitral annulus (CCMA) then develops. Detection of CCMA is often random and requires differentiation from heart tumors or an abscess. The paper presents two cases of patients with ambiguous focal lesions of the mitral valve in echocardiography. In the first case, the cardiac computed tomography (CCT) showed a spherical, slightly irregular structure measuring approximately 33 × 22 mm, which was in contact with the posterior mitral valve leaflet from the lumen of the left ventricle. The lesion was heterogeneously intense, with an average density of about 500 HU and up to 975 HU on the periphery; it was not enhanced after the administration of a contrast agent. In the second case, the CCT revealed a heterogeneous, highly calcified structure in the peripheral zone and intermediate density in the central zone in the topography of the posterior mitral valve leaf, with dimensions up to about 41 × 31 mm in the plane of the valve leaflet, passing into the lumen of the left ventricle along its inferolateral wall to a depth of about 3.5 cm. In both cases, CCT enabled the diagnosis of CCMA. In conclusion, cardiac computed tomography may be decisive in the case of suspected caseous calcification of the mitral annulus where there is ambiguous echocardiography.
Collapse
Affiliation(s)
- Paweł Gać
- Centre for Diagnostic Imaging, 4th Military Hospital, Weigla 5, PL 50-981 Wroclaw, Poland;
- Department of Population Health, Division of Environmental Health and Occupational Medicine, Wroclaw Medical University, Mikulicza-Radeckiego 7, PL 50-368 Wroclaw, Poland
- Correspondence: or
| | - Przemysław Cheładze
- Centre for Diagnostic Imaging, 4th Military Hospital, Weigla 5, PL 50-981 Wroclaw, Poland;
| | - Rafał Poręba
- Department of Internal and Occupational Diseases, Hypertension and Clinical Oncology, Wroclaw Medical University, Borowska 213, PL 50-556 Wroclaw, Poland;
| |
Collapse
|
11
|
Azhar AZ, Rai D, Bandyopadhyay D, Rzechorzek W, Akhtar T, Aronow WS, Ranjan P. Use of coronary artery calcium and coronary tomography angiography in the evaluation of ischemic heart disease. Hosp Pract (1995) 2022; 50:9-16. [PMID: 35037541 DOI: 10.1080/21548331.2022.2030630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Over the years, significant technological advances have been made in the field of cardiac CT imaging which has led to the widespread use of the modality in the evaluation of ischemic and structural heart disease. The advent of newer scanning techniques has led to a reduction in scanning time as well as a reduction in the radiation and contrast media dose required - making these scans both convenient and safer to perform. Research has shown that coronary CT angiography has a high negative predictive value in the evaluation of patients with coronary artery disease. There is more recent evidence that coronary CTA has a positive impact on clinical outcomes as well. In this review article, we discuss the clinical applications of coronary CTA in the evaluation of patients with stable ischemic heart disease, the most recent studies evaluating the efficacy and limitations of the modality, the role of coronary calcium in cardiovascular risk prediction in asymptomatic patients and the future applications of the modality.
Collapse
Affiliation(s)
| | - Devesh Rai
- Department of Cardiology, Rochester General Hospital, Rochester, NY, USA
| | | | - Wojciech Rzechorzek
- Department of Cardiology, Westchester Medical Center at New York Medical College, Valhalla, NY, USA
| | - Tauseef Akhtar
- Medicine, John's Hopkins University School of Medicine, Baltimore, MD, USA
| | - Wilbert S Aronow
- Department of Cardiology, Westchester Medical Center at New York Medical College, Valhalla, NY, USA
| | - Pragya Ranjan
- Department of Cardiology, Westchester Medical Center at New York Medical College, Valhalla, NY, USA
| |
Collapse
|
12
|
Zhang L, Li L, Feng G, Fan T, Jiang H, Wang Z. Advances in CT Techniques in Vascular Calcification. Front Cardiovasc Med 2021; 8:716822. [PMID: 34660718 PMCID: PMC8511450 DOI: 10.3389/fcvm.2021.716822] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Accepted: 08/30/2021] [Indexed: 12/17/2022] Open
Abstract
Vascular calcification, a common pathological phenomenon in atherosclerosis, diabetes, hypertension, and other diseases, increases the incidence and mortality of cardiovascular diseases. Therefore, the prevention and detection of vascular calcification play an important role. At present, various techniques have been applied to the analysis of vascular calcification, but clinical examination mainly depends on non-invasive and invasive imaging methods to detect and quantify. Computed tomography (CT), as a commonly used clinical examination method, can analyze vascular calcification. In recent years, with the development of technology, in addition to traditional CT, some emerging types of CT, such as dual-energy CT and micro CT, have emerged for vascular imaging and providing anatomical information for calcification. This review focuses on the latest application of various CT techniques in vascular calcification.
Collapse
Affiliation(s)
- Lijie Zhang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Lihua Li
- Department of Pathology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Guoquan Feng
- Department of Radiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Tingpan Fan
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Han Jiang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| | - Zhongqun Wang
- Department of Cardiology, Affiliated Hospital of Jiangsu University, Zhenjiang, China
| |
Collapse
|
13
|
Coronary Computer Tomography Angiography in 2021-Acquisition Protocols, Tips and Tricks and Heading beyond the Possible. Diagnostics (Basel) 2021; 11:diagnostics11061072. [PMID: 34200866 PMCID: PMC8230532 DOI: 10.3390/diagnostics11061072] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/06/2021] [Accepted: 06/09/2021] [Indexed: 01/09/2023] Open
Abstract
Recent technological advances, together with an increasing body of evidence from randomized trials, have placed coronary computer tomography angiography (CCTA) in the center of the diagnostic workup of patients with coronary artery disease. The method was proven reliable in the diagnosis of relevant coronary artery stenosis. Furthermore, it can identify different stages of the atherosclerotic process, including early atherosclerotic changes of the coronary vessel wall, a quality not met by other non-invasive tests. In addition, newer computational software can measure the hemodynamic relevance (fractional flow reserve) of a certain stenosis. In addition, if required, information related to cardiac and valvular function can be provided with specific protocols. Importantly, recent trials have highlighted the prognostic relevance of CCTA in patients with coronary artery disease, which helped establishing CCTA as the first-line method for the diagnostic work-up of such patients in current guidelines. All this can be gathered in one relatively fast examination with minimal discomfort for the patient and, with newer machines, with very low radiation exposure. Herein, we provide an overview of the current technical aspects, indications, pitfalls, and new horizons with CCTA, providing examples from our own clinical practice.
Collapse
|