1
|
Zhu L, Cao H, Ma J, Wang L. Optical ultrasound sensors for photoacoustic imaging: a review. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11523. [PMID: 38303991 PMCID: PMC10831871 DOI: 10.1117/1.jbo.29.s1.s11523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 01/08/2024] [Accepted: 01/10/2024] [Indexed: 02/03/2024]
Abstract
Significance Photoacoustic (PA) imaging is an emerging biomedical imaging modality that can map optical absorption contrast in biological tissues by detecting ultrasound signal. Piezoelectric transducers are commonly used in PA imaging to detect the ultrasound signals. However, piezoelectric transducers suffer from low sensitivity when the dimensions are reduced and are easily influenced by electromagnetic interference. To avoid these limitations, various optical ultrasound sensors have been developed and shown their great potential in PA imaging. Aim Our study aims to summarize recent progress in optical ultrasound sensor technologies and their applications in PA imaging. Approach The commonly used optical ultrasound sensing techniques and their applications in PA systems are reviewed. The technical advances of different optical ultrasound sensors are summarized. Results Optical ultrasound sensors can provide wide bandwidth and improved sensitivity with miniatured size, which enables their applications in PA imaging. Conclusions The optical ultrasound sensors are promising transducers in PA imaging to provide higher-resolution images and can be used in new applications with their unique advantages.
Collapse
Affiliation(s)
- Liying Zhu
- City University of Hong Kong, Department of Biomedical Engineering, Kowloon, Hong Kong, China
| | - Hongming Cao
- City University of Hong Kong, Department of Biomedical Engineering, Kowloon, Hong Kong, China
| | - Jun Ma
- Nanfang Hospital, Southern Medical University, Department of Burns, Guangzhou, China
| | - Lidai Wang
- City University of Hong Kong, Department of Biomedical Engineering, Kowloon, Hong Kong, China
| |
Collapse
|
2
|
Zhang S, Bodian S, Zhang EZ, Beard PC, Noimark S, Desjardins AE, Colchester RJ. Miniaturised dual-modality all-optical ultrasound probe for laser interstitial thermal therapy (LITT) monitoring. BIOMEDICAL OPTICS EXPRESS 2023; 14:3446-3457. [PMID: 37497509 PMCID: PMC10368049 DOI: 10.1364/boe.494892] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/09/2023] [Accepted: 06/13/2023] [Indexed: 07/28/2023]
Abstract
All-optical ultrasound (OpUS) has emerged as an imaging paradigm well-suited to minimally invasive imaging due to its ability to provide high resolution imaging from miniaturised fibre optic devices. Here, we report a fibre optic device capable of concurrent laser interstitial thermal therapy (LITT) and real-time in situ all-optical ultrasound imaging for lesion monitoring. The device comprised three optical fibres: one each for ultrasound transmission, reception and thermal therapy light delivery. This device had a total lateral dimension of <1 mm and was integrated into a medical needle. Simultaneous LITT and monitoring were performed on ex vivo lamb kidney with lesion depth tracked using M-mode OpUS imaging. Using one set of laser energy parameters for LITT (5 W, 60 s), the lesion depth varied from 3.3 mm to 8.3 mm. In all cases, the full lesion depth could be visualised and measured with the OpUS images and there was a good statistical agreement with stereomicroscope images acquired after ablation (t=1.36, p=0.18). This work demonstrates the feasibility and potential of OpUS to guide LITT in tumour resection.
Collapse
Affiliation(s)
- Shaoyan Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| | - Semyon Bodian
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
- Materials Chemistry Centre, Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, UK
| | - Edward Z. Zhang
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
| | - Paul C. Beard
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| | - Sacha Noimark
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
- Materials Chemistry Centre, Department of Chemistry, University College London, 20 Gordon Street, London WC1H 0AJ, UK
| | - Adrien E. Desjardins
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| | - Richard J. Colchester
- Department of Medical Physics and Biomedical Engineering, University College London, Malet Place Engineering Building, London WC1E 6BT, UK
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, Charles Bell House, University College London, 43-45 Foley Street, London W1W 7TY, UK
| |
Collapse
|
3
|
Lin WK, Ni L, Wang X, Guo JL, Xu G. Fabrication of a translational photoacoustic needle sensing probe for interstitial photoacoustic spectral analysis. PHOTOACOUSTICS 2023; 31:100519. [PMID: 37362870 PMCID: PMC10285275 DOI: 10.1016/j.pacs.2023.100519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 05/29/2023] [Accepted: 05/31/2023] [Indexed: 06/28/2023]
Abstract
In our previous study, we demonstrated the feasibility of using an all-optical interstitial photoacoustic (PA) needle sensing probe for quantitative study of tissue architectures with PA spectral analysis (PASA). In this work, we integrated the optical components into an 18 G steel needle sheath for clinical translation. The dimensions of the needle probe are identical to those of a core biopsy probe and are fully compatible with standard procedures such as prostate biopsy. To our knowledge, this is the first interstitial PA probe that can acquire signals with sufficient temporal length for statistics-based PASA. We treated the inner surface of the steel needle sheath and successfully suppressed the vibrational PA signals generated at the surface. Purposed at boosting the measurement sensitivity and extending sensing volume, we upgraded the Fabry-Pérot hydrophone with a plano-concave structure. The performance of the translational needle PA sensing probe was examined with phantoms containing microspheres. The trend of the linear spectral slopes shows negatively correlated to the microsphere dimensions while the midband-fits are positively correlated to microsphere diameters and concentrations. The PASA quantifications show the ability to differentiate microspheres with varied dimensions.
Collapse
Affiliation(s)
- Wei-Kuan Lin
- Department of Electrical Engineering and Computer Sciences, University of Michigan, 1301 Beal Avenue, Ann Arbor, MI, USA
| | - Linyu Ni
- Department of Biomedical Engineering, University of Michigan, 2200 Bonisteel Blvd, Ann Arbor, MI, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, 2200 Bonisteel Blvd, Ann Arbor, MI, USA
- Department of Radiology, University of Michigan, 1301 Catherine St, Ann Arbor, MI, USA
| | - Jay L. Guo
- Department of Electrical Engineering and Computer Sciences, University of Michigan, 1301 Beal Avenue, Ann Arbor, MI, USA
| | - Guan Xu
- Department of Biomedical Engineering, University of Michigan, 2200 Bonisteel Blvd, Ann Arbor, MI, USA
- Department of Ophthalmology and Visual Sciences, University of Michigan, 1000 Wall St, Ann Arbor, MI, USA
| |
Collapse
|
4
|
Yu R, Li X, Zhen Y, Xue B. Estimation of underwater acoustic direction-of-arrival using the probe beam deflection technique. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:987-995. [PMID: 37133196 DOI: 10.1364/josaa.484800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This paper proposes a method of estimating the underwater acoustic direction-of-arrival using several laser beams impinging on a propagating underwater acoustic wave. The deflection of the laser beam caused by the spatial variation of the optical refractive index, which is further due to the modulation of the acoustic wave, reflects the information of direction-of-arrival and is sensed by the position sensitive detector (PSD). The sensing of the minute displacement on the PSD, in fact, introduces an extra dimension in the depth direction, which is a significant advantage over the conventional piezoelectric sensing regime. The employment of the extra sensing dimension can overcome several shortcomings, represented by spatial aliasing and phase ambiguity, existing in the current direction-of-arrival estimating methods. In addition, the ringing phenomenon of the piezoelectric effect is greatly reduced in the proposed laser-based sensing regime. By the flexibility of placing the laser beams, a prototype of the hydrophone is designed and manufactured, and a series of testing is performed. The results show that, benefiting from the probe beam deflection technique and combining the rough estimate and fine calculation, the resolution of the underwater acoustic direction-of-arrival can be improved to better than 0.016°, which can support and reform many underwater applications such as underwater acoustic communication, underwater detection, and ocean monitoring.
Collapse
|