Fan N, Chen X, Li Y, Zhu Z, Chen X, Yang Z, Yang J. Dual-energy computed tomography with new virtual monoenergetic image reconstruction enhances prostate lesion image quality and improves the diagnostic efficacy for prostate cancer. BMC Med Imaging 2024; 24:212. [PMID: 39134937 DOI: 10.1186/s12880-024-01393-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 08/05/2024] [Indexed: 08/15/2024] Open
Abstract
BACKGROUND Prostate cancer is one of the most common malignant tumors in middle-aged and elderly men and carries significant prognostic implications, and recent studies suggest that dual-energy computed tomography (DECT) utilizing new virtual monoenergetic images can enhance cancer detection rates. This study aimed to assess the impact of virtual monoenergetic images reconstructed from DECT arterial phase scans on the image quality of prostate lesions and their diagnostic performance for prostate cancer. METHODS We conducted a retrospective analysis of 83 patients with prostate cancer or prostatic hyperplasia who underwent DECT scans at Meizhou People's Hospital between July 2019 and December 2023. The variables analyzed included age, tumor diameter and serum prostate-specific antigen (PSA) levels, among others. We also compared CT values, signal-to-noise ratio (SNR), subjective image quality ratings, and contrast-to-noise ratio (CNR) between virtual monoenergetic images (40-100 keV) and conventional linear blending images. Receiver operating characteristic (ROC) curve analyses were performed to evaluate the diagnostic efficacy of virtual monoenergetic images (40 keV and 50 keV) compared to conventional images. RESULTS Virtual monoenergetic images at 40 keV showed significantly higher CT values (168.19 ± 57.14) compared to conventional linear blending images (66.66 ± 15.5) for prostate cancer (P < 0.001). The 50 keV images also demonstrated elevated CT values (121.73 ± 39.21) compared to conventional images (P < 0.001). CNR values for the 40 keV (3.81 ± 2.13) and 50 keV (2.95 ± 1.50) groups were significantly higher than the conventional blending group (P < 0.001). Subjective evaluations indicated markedly better image quality scores for 40 keV (median score of 5) and 50 keV (median score of 5) images compared to conventional images (P < 0.05). ROC curve analysis revealed superior diagnostic accuracy for 40 keV (AUC: 0.910) and 50 keV (AUC: 0.910) images based on CT values compared to conventional images (AUC: 0.849). CONCLUSIONS Virtual monoenergetic images reconstructed at 40 keV and 50 keV from DECT arterial phase scans substantially enhance the image quality of prostate lesions and improve diagnostic efficacy for prostate cancer.
Collapse
Affiliation(s)
- Nina Fan
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China
| | - Xiaofeng Chen
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China
| | - Yulin Li
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China
| | - Zhiqiang Zhu
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China
| | - Xiangguang Chen
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China
| | - Zhiqi Yang
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
| | - Jiada Yang
- Department of Radiology, Meizhou People's Hospital, Meizhou, 514000, Guangdong, China.
| |
Collapse
|
2
|
Greffier J, Faby S, Pastor M, Frandon J, Erath J, Beregi JP, Dabli D. Comparison of the spectral performance between two dual-source CT systems on low-energy virtual monoenergetic images: A phantom study. Phys Med 2024; 124:103429. [PMID: 39024963 DOI: 10.1016/j.ejmp.2024.103429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 07/01/2024] [Accepted: 07/08/2024] [Indexed: 07/20/2024] Open
Abstract
PURPOSE To compare the spectral performance of two different DSCT (DSCT-Pulse and DSCT-Force) on virtual monoenergetic images (VMIs) at low energy levels. METHODS An image quality phantom was scanned on the two DSCTs at three dose levels: 11/6/1.8 mGy. Level 3 of an advanced modeled iterative reconstruction algorithm was used. Noise power spectrum and task-based transfer function were computed on VMIs from 40 to 70 keV to assess noise magnitude and noise texture (fav) and spatial resolution (f50). A detectability index (d') was computed to assess the detection of one contrast-enhanced abdominal lesion as a function of the keV level used. RESULTS For all dose levels and all energy levels, noise magnitude was significantly higher (p < 0.05) with DSCT-Pulse than with DSCT-Force (12.6 ± 2.7 % at 1.8 mGy, 9.1 ± 2.9 % at 6 mGy and 4.0 ± 2.7 % at 11 mGy). For all energy levels, fav values were significantly higher (p < 0.05) with DSCT-Pulse than with DSCT-Force at 1.8 mGy (4.8 ± 3.9 %) and at 6 mGy (5.5 ± 2.5 %) but similar at 11 mGy (0.2 ± 3.6 %; p = 0.518). For all energy levels, f50 values were significantly higher with DSCT-Pulse than with DSCT-Force (12.7 ± 5.6 % at 1.8 mGy, 17.9 ± 4.5 % at 6 mGy and 13.1 ± 2.6 % at 11 mGy). For all keV, similar d' values were found with both DSCT-Force and DSCT-Pulse at 11 mGy (-1.0 ± 3.1 %; p = 0.084). For other dose levels, d' values were significantly lower with DSCT-Pulse than with DSCT-Force (9.1 ± 3.2 % at 1.8 mGy and -6.3 ± 3.9 % at 6 mGy). CONCLUSION Compared with the DSCT-Force, the DSCT-Pulse improved noise texture and spatial resolution, but noise magnitude was slightly higher and detectability slightly lower, particularly when the dose level was reduced.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France.
| | - Sebastian Faby
- Department of Computed Tomography, Siemens Healthineers AG, Siemensstr. 3, 91301 Forchheim, Germany
| | - Maxime Pastor
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France
| | - Julien Frandon
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France
| | - Julien Erath
- Department of Computed Tomography, Siemens Healthineers AG, Siemensstr. 3, 91301 Forchheim, Germany
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France
| | - Djamel Dabli
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France
| |
Collapse
|
3
|
Greffier J, Faby S, Pastor M, Frandon J, Erath J, Beregi JP, Dabli D. Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study. Diagn Interv Imaging 2024:S2211-5684(24)00044-5. [PMID: 38429207 DOI: 10.1016/j.diii.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 02/17/2024] [Accepted: 02/19/2024] [Indexed: 03/03/2024]
Abstract
PURPOSE The purpose of this study was to assess image quality and dose level using a photon-counting CT (PCCT) scanner by comparison with a dual-source CT (DSCT) scanner on virtual monoenergetic images (VMIs) at low energy levels. MATERIALS AND METHODS A phantom was scanned using a DSCT and a PCCT with a volume CT dose index of 11 mGy, and additionally at 6 mGy and 1.8 mGy for PCCT. Noise power spectrum and task-based transfer function were evaluated from 40 to 70 keV on VMIs to assess noise magnitude and noise texture (fav) and spatial resolution on two iodine inserts (f50), respectively. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions according to the energy level used. RESULTS For all energy levels, noise magnitude values were lower with PCCT than with DSCT at 11 and 6 mGy, but greater at 1.8 mGy. fav values were higher with PCCT than with DSCT at 11 mGy (8.6 ± 1.5 [standard deviation [SD]%), similar at 6 mGy (1.6 ± 1.5 [SD]%) and lower at 1.8 mGy (-17.8 ± 2.2 [SD]%). For both inserts, f50 values were higher with PCCT than DSCT at 11- and 6 mGy for all keV levels, except at 6 mGy and 40 keV. d' values were higher with PCCT than with DSCT at 11- and 6 mGy for all keV and both simulated lesions. Similar d' values to those of the DSCT at 11 mGy, were obtained at 2.25 mGy for iodine insert at 2 mg/mL and at 0.96 mGy for iodine insert at 4 mg/mL at 40 keV. CONCLUSION Compared to DSCT, PCCT reduces noise magnitude and improves noise texture, spatial resolution and detectability on VMIs for all low-keV levels.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France.
| | - Sebastian Faby
- Department of Computed Tomography, Siemens Healthineers AG, 91301 Forchheim, Germany
| | - Maxime Pastor
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France
| | - Julien Frandon
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France
| | - Julien Erath
- Department of Computed Tomography, Siemens Healthineers AG, 91301 Forchheim, Germany
| | - Jean Paul Beregi
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France
| | - Djamel Dabli
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France
| |
Collapse
|
4
|
Zhong J, Wu Z, Wang L, Chen Y, Xia Y, Wang L, Li J, Lu W, Shi X, Feng J, Dong H, Zhang H, Yao W. Impacts of Adaptive Statistical Iterative Reconstruction-V and Deep Learning Image Reconstruction Algorithms on Robustness of CT Radiomics Features: Opportunity for Minimizing Radiomics Variability Among Scans of Different Dose Levels. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024; 37:123-133. [PMID: 38343265 DOI: 10.1007/s10278-023-00901-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 03/02/2024]
Abstract
This study aims to investigate the influence of adaptive statistical iterative reconstruction-V (ASIR-V) and deep learning image reconstruction (DLIR) on CT radiomics feature robustness. A standardized phantom was scanned under single-energy CT (SECT) and dual-energy CT (DECT) modes at standard and low (20 and 10 mGy) dose levels. Images of SECT 120 kVp and corresponding DECT 120 kVp-like virtual monochromatic images were generated with filtered back-projection (FBP), ASIR-V at 40% (AV-40) and 100% (AV-100) blending levels, and DLIR algorithm at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) strength levels. Ninety-four features were extracted via Pyradiomics. Reproducibility of features was calculated between standard and low dose levels, between reconstruction algorithms in reference to FBP images, and within scan mode, using intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). The average percentage of features with ICC > 0.90 and CCC > 0.90 between the two dose levels was 21.28% and 20.75% in AV-40 images, and 39.90% and 35.11% in AV-100 images, respectively, and increased from 15.43 to 45.22% and from 15.43 to 44.15% with an increasing strength level of DLIR. The average percentage of features with ICC > 0.90 and CCC > 0.90 in reference to FBP images was 26.07% and 25.80% in AV-40 images, and 18.88% and 18.62% in AV-100 images, respectively, and decreased from 27.93 to 17.82% and from 27.66 to 17.29% with an increasing strength level of DLIR. DLIR and ASIR-V algorithms showed low reproducibility in reference to FBP images, while the high-strength DLIR algorithm provides an opportunity for minimizing radiomics variability due to dose reduction.
Collapse
Affiliation(s)
- Jingyu Zhong
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China
| | - Zhiyuan Wu
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Lingyun Wang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Yong Chen
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Yihan Xia
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Lan Wang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Jianying Li
- Computed Tomography Research Center, GE Healthcare, Beijing, 100176, China
| | - Wei Lu
- Computed Tomography Research Center, GE Healthcare, Shanghai, 201203, China
| | - Xiaomeng Shi
- Department of Materials, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - Jianxing Feng
- Haohua Technology Co., Ltd., Shanghai, 201100, China
| | - Haipeng Dong
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| | - Huan Zhang
- Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| | - Weiwu Yao
- Department of Imaging, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200336, China.
| |
Collapse
|
5
|
Pettersson E, Thilander-Klang A, Bäck A. Prediction of proton stopping power ratios using dual-energy CT basis material decomposition. Med Phys 2024; 51:881-897. [PMID: 38194501 DOI: 10.1002/mp.16929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 12/04/2023] [Accepted: 12/15/2023] [Indexed: 01/11/2024] Open
Abstract
BACKGROUND Proton radiotherapy treatment plans are currently restricted by the range uncertainties originating from the stopping power ratio (SPR) prediction based on single-energy computed tomography (SECT). Various studies have shown that multi-energy CT (MECT) can reduce the range uncertainties due to medical implant materials and age-related variations in tissue composition. None of these has directly applied the basis material density (MD) images produced by projection-based MECT systems for SPR prediction. PURPOSE To present and evaluate a novel proton SPR prediction method based on MD images from dual-energy CT (DECT), which could reduce the range uncertainties currently associated with proton radiotherapy. METHODS A theoretical basis material decomposition into water and iodine material densities was performed for various pediatric and adult human reference tissues, as well as other non-tissue materials, by minimizing the root-mean-square relative attenuation error in the energy interval from 40 to 140 keV. A model (here called MD-SPR) mapping predicted MDs to theoretically calculated reference SPRs was created with locally weighted scatterplot smoothing (LOWESS) data-fitting. The goodness of fit of the MD-SPR model was evaluated for the included reference tissues. MD images of two electron density phantoms, combined to form a head- and an abdomen-sized phantom setup, were acquired with a clinical projection-based fast-kV switching DECT scanner. The MD images were compared to the theoretically predicted MDs of the tissue surrogates and other non-tissue materials in the phantoms, as well as used for input to the MD-SPR model for generation of SPR images. The SPR images were subsequently compared to theoretical reference SPRs of the materials in the phantoms, as well as to SPR images from a commercial algorithm (DirectSPR, Siemens Healthineers, Forchheim, Germany) using image-based consecutive scan DECT for the same phantom setups. RESULTS The predicted SPRs of the tissue surrogates were similar for MD-SPR and DirectSPR, where the adipose and bone tissue surrogates were within 1% difference to the reference SPRs, while other non-adipose soft tissue surrogates (breast, brain, liver, muscle) were all underestimated by between -0.7% and -1.8%. The SPRs of the non-tissue materials (polymethyl methacrylate (PMMA), polyether ether ketone (PEEK), graphite and Teflon) were within 2.8% for MD-SPR images, compared to 6.8% for DirectSPR. CONCLUSIONS The MD-SPR model performed similar compared to other published methods for the human reference tissues. The SPR prediction for tissue surrogates was similar to DirectSPR and showed potential to improve SPR prediction for non-tissue materials.
Collapse
Affiliation(s)
- Erik Pettersson
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Therapeutic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anne Thilander-Klang
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Diagnostic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Anna Bäck
- Department of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Therapeutic Radiation Physics, Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
6
|
Greffier J, Van Ngoc Ty C, Fitton I, Frandon J, Beregi JP, Dabli D. Spectral performance of two split-filter dual-energy CT systems: A phantom study. Med Phys 2023; 50:6828-6835. [PMID: 37672341 DOI: 10.1002/mp.16701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 07/31/2023] [Accepted: 07/31/2023] [Indexed: 09/08/2023] Open
Abstract
BACKGROUND Recently, a second generation of split filter dual-energy CT (SFCT) platform has been developed. The thicknesses of the gold and tin filters used to obtain both low- and high-energy spectra have been changed. These differences in filter thickness may affect the spectral separation between the two spectra and thus the quality of spectral images. PURPOSE To compare the spectral performance of two Split-Filter Dual-Energy CT systems (SFCT-1st and SFCT-2nd ) on virtual monoenergetic images (VMIs) and iodine map. METHODS A Multi-Energy CT phantom was scanned on two SFCT with a tube voltage of 120 kVp for both systems (SFCT-1st -120 and SFCT-2nd -120) and 140 kVp only for the second generation (SFCT-2nd -140). Acquisitions were performed on the phantom with a CTDIvol close to 11 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated on VMIs from 40 to 70 keV. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions on VMIs. Hounsfield Unit (HU) accuracy was assessed on VMIs and the accuracy of iodine concentration was assessed on iodine maps. RESULTS For all keV, noise magnitude values were lower with the SFCT-2nd -120 than with the SFCT-1st -120 (on average: -22.5 ± 2.9%) and higher with the SFCT-2nd -140 than with the SFCT-2nd -120 (on average: 25.0 ± 6.2%). Average NPS spatial frequencies (fav ) were lower with the SFCT-1st -120 than with the SFCT-2nd -120 (-6.0 ± 0.5%) and the SFCT-2nd -140 (-3.6 ± 1.6%). Similar TTF50% values were found for both systems and both kVp for blood and iodine inserts at 2 mg/mL (0.29 ± 0.01 mm-1 ) and at 4 mg/mL (0.31 ± 0.01 mm-1 ). d' values peaked at 40 keV for the SFCT-2nd and at 70 keV for the SFCT-1st . Highest d' values were found for the SFCT-2nd -120 for both simulated lesions. Accuracy of HU values and iodine concentration was higher with the SFCT-2nd than with the SFCT 1st . CONCLUSION Compared to the SFCT-1st , with similar spatial resolution and noise texture values, the SFCT-2nd -120 exhibited the lowest values for noise magnitude, the highest detectability index values, and more accurate HU values and iodine concentrations.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Claire Van Ngoc Ty
- Université de Paris, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Department of Radiology, Paris, France
| | - Isabelle Fitton
- Université de Paris, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Department of Radiology, Paris, France
| | - Julien Frandon
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Djamel Dabli
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| |
Collapse
|
7
|
Greffier J, Van Ngoc Ty C, Fitton I, Frandon J, Beregi JP, Dabli D. Impact of Phantom Size on Low-Energy Virtual Monoenergetic Images of Three Dual-Energy CT Platforms. Diagnostics (Basel) 2023; 13:3039. [PMID: 37835782 PMCID: PMC10572153 DOI: 10.3390/diagnostics13193039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/18/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% ± 1.3%) and 31 cm (7.0% ± 2.5%), and the opposite for 36 cm (-4.2% ± 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% ± 0.4%) and the opposite for 31 cm (-6.9% ± 0.5%) and 36 cm (-5.6% ± 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% ± 0.7%), similar for 31 cm (-0.3% ± 1.9%) and higher for 36 cm (5.4% ± 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.
Collapse
Affiliation(s)
- Joël Greffier
- IMAGINE UR UM 103, Department of Medical Imaging, Nimes University Hospital, Montpellier University, 30029 Nimes, France; (J.F.); (J.-P.B.); (D.D.)
| | - Claire Van Ngoc Ty
- Department of Radiology, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Université de Paris, 75015 Paris, France; (C.V.N.T.); (I.F.)
| | - Isabelle Fitton
- Department of Radiology, Assistance Publique Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Université de Paris, 75015 Paris, France; (C.V.N.T.); (I.F.)
| | - Julien Frandon
- IMAGINE UR UM 103, Department of Medical Imaging, Nimes University Hospital, Montpellier University, 30029 Nimes, France; (J.F.); (J.-P.B.); (D.D.)
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Department of Medical Imaging, Nimes University Hospital, Montpellier University, 30029 Nimes, France; (J.F.); (J.-P.B.); (D.D.)
| | - Djamel Dabli
- IMAGINE UR UM 103, Department of Medical Imaging, Nimes University Hospital, Montpellier University, 30029 Nimes, France; (J.F.); (J.-P.B.); (D.D.)
| |
Collapse
|
8
|
D’Angelo T, Lanzafame LRM, Micari A, Blandino A, Yel I, Koch V, Gruenewald LD, Vogl TJ, Booz C, Bucolo GM, Cannizzaro MT, Ascenti G, Mazziotti S. Improved Coronary Artery Visualization Using Virtual Monoenergetic Imaging from Dual-Layer Spectral Detector CT Angiography. Diagnostics (Basel) 2023; 13:2675. [PMID: 37627934 PMCID: PMC10453590 DOI: 10.3390/diagnostics13162675] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 08/07/2023] [Accepted: 08/09/2023] [Indexed: 08/27/2023] Open
Abstract
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72-0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.
Collapse
Affiliation(s)
- Tommaso D’Angelo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
- Department of Radiology and Nuclear Medicine, Erasmus MC, 3015 GD Rotterdam, The Netherlands
| | - Ludovica R. M. Lanzafame
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Antonino Micari
- Department of Clinical and Experimental Medicine, DIMED, University Hospital Messina, 98124 Messina, Italy;
| | - Alfredo Blandino
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Ibrahim Yel
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Vitali Koch
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Leon D. Gruenewald
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Thomas J. Vogl
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Christian Booz
- Division of Experimental Imaging, Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, 60590 Frankfurt am Main, Germany; (I.Y.); (V.K.); (L.D.G.); (T.J.V.); (C.B.)
| | - Giuseppe M. Bucolo
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Maria Teresa Cannizzaro
- Radiology Unit (CAST), University Hospital Catania, “Policlinico G. Rodolico–San Marco”, 95123 Catania, Italy;
| | - Giorgio Ascenti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| | - Silvio Mazziotti
- Diagnostic and Interventional Radiology Unit, BIOMORF Department, University Hospital Messina, 98124 Messina, Italy; (L.R.M.L.); (A.B.); (G.M.B.); (G.A.); (S.M.)
| |
Collapse
|
9
|
Sakai Y, Shirasaka T, Hioki K, Yamane S, Kinoshita E, Kato T. Effects of scan parameters on the accuracies of iodine quantification and hounsfield unit values in dual layer dual-energy head and neck computed tomography: A phantom study conducted in a hospital in Japan. Radiography (Lond) 2023; 29:838-844. [PMID: 37393738 DOI: 10.1016/j.radi.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/14/2023] [Accepted: 06/18/2023] [Indexed: 07/04/2023]
Abstract
INTRODUCTION No study has investigated scan parameters in head and neck dual layer dual-energy computed tomography (DL-DECT). This study aimed to select the appropriate scan parameters in head and neck imaging by evaluating the scan parameter effects on the accuracies of CT numbers and conduct iodine quantification in DL-DECT. METHODS A multi-energy phantom was scanned using a dual layer CT (DLCT) scanner. Reference materials of iodine, blood, calcium, and adipose were used. A helical scan was performed by using reference and several protocols. Iodine density and virtual monochromatic images (VMIs) at the energy of 50, 70, and 100 keV were reconstructed. The iodine concentrations and CT numbers in each protocol were measured. Moreover, the absolute percentage errors (APEs) of iodine quantifications and CT numbers (reference vs. each protocol) were compared. Equivalence was observed when APEs between reference and each protocol was within 5%. Statistical analysis was performed using appropriate software. RESULTS The APEs between the high-tube-voltage and reference protocol were 23.7, 14.0, 8.8, and 8.1% for iodine reference materials with concentrations equal to 2, 5, 10, and 15 mg/ml, respectively. At 50 keV, APEs between the high-tube-voltage and reference protocols were greater than 5% except for calcium and adipose. At 100 keV, APEs between the high-tube-voltage and reference protocols were greater than 5% except for blood and calcium. CONCLUSIONS The high-tube-voltage protocol improved the accuracies of the measurement for iodine quantification and CT numbers. Additionally, the scanning parameters except for tube voltage had no effect on accuracies of iodine quantitation and CT numbers in the DLCT scanner. IMPLICATIONS FOR PRACTICE The use of the high-tube-voltage protocol will be recommended for more accurate material decomposition in head and neck DL-DECT.
Collapse
Affiliation(s)
- Y Sakai
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - T Shirasaka
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - K Hioki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - S Yamane
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - E Kinoshita
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - T Kato
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| |
Collapse
|
10
|
Dabli D, Durand Q, Frandon J, de Oliveira F, Pastor M, Beregi J, Greffier J. Impact of the automatic tube current modulation (ATCM) system on virtual monoenergetic image quality for dual-source CT: A phantom study. Phys Med 2023; 109:102574. [PMID: 37004360 DOI: 10.1016/j.ejmp.2023.102574] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 02/23/2023] [Accepted: 03/22/2023] [Indexed: 04/03/2023] Open
Abstract
PURPOSE To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT). MATERIALS AND METHODS Acquisitions were performed on DSCT using the Mercury phantom. The acquisition parameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions. This value was used as the reference mAs in ATCM acquisitions. The noise power spectrum and task-based transfer function at 40,50,60 and 70 keV levels were computed on VMIs and SECT images. The detectability index (d') was calculated for a lesion with an iodine concentration of 10 mg/mL. RESULTS The noise magnitude on VMIs was higher with the ATCM system than with fixed mAs for all energy levels and section diameters of 21,26 and 31 cm. The noise texture and spatial resolution were similar between the fixed mAs and ATCM acquisitions for both imaging modes. The d' values were lower for all energy levels with ATCM than with fixed mAs acquisitions for 21 and 26 cm diameters by -39.82 ± 9.32%, similar at 31 cm diameter -4.13 ± 0.24% and higher at 36 cm diameter 10.40 ± 6.69%. It was higher on VMIs at all energy levels compared to SECT images. CONCLUSIONS The ATCM system could be used with DECT imaging to optimize patient exposure without changing the noise texture and spatial resolution of VMIs compared to fixed mAs and SECT.
Collapse
|
11
|
Sartoretti T, McDermott M, Mergen V, Euler A, Schmidt B, Jost G, Wildberger JE, Alkadhi H. Photon-counting detector coronary CT angiography: impact of virtual monoenergetic imaging and iterative reconstruction on image quality. Br J Radiol 2023; 96:20220466. [PMID: 36633005 PMCID: PMC9975359 DOI: 10.1259/bjr.20220466] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 09/30/2022] [Accepted: 11/08/2022] [Indexed: 01/13/2023] Open
Abstract
OBJECTIVES To assess the impact of low kilo-electronvolt (keV) virtual monoenergetic image (VMI) energies and iterative reconstruction on image quality of clinical photon-counting detector coronary CT angiography (CCTA). METHODS CCTA with PCD-CT (prospective ECG-triggering, 120 kVp, automatic tube current modulation) was performed in a high-end cardiovascular phantom with dynamic flow, pulsatile heart motion, and including different calcified plaques with various stenosis grades and in 10 consecutive patients. VMI at 40,50,60 and 70 keV were reconstructed without (QIR-off) and with all quantum iterative reconstruction (QIR) levels (QIR-1 to 4). In the phantom, noise power spectrum, vessel attenuation, contrast-to-noise-ratio (CNR), and vessel sharpness were measured. Two readers graded stenoses in the phantom and graded overall image quality, subjective noise, vessel sharpness, vascular contrast, and coronary artery plaque delineation on 5-point Likert scales in patients. RESULTS In the phantom, noise texture was only slightly affected by keV and QIR while noise increased by 69% from 70 keV QIR-4 to 40 keV QIR-off. Reconstructions at 40 keV QIR-4 exhibited the highest CNR (46.1 ± 1.8), vessel sharpness (425 ± 42 ∆HU/mm), and vessel attenuation (1098 ± 14 HU). Stenosis measurements were not affected by keV or QIR level (p > 0.12) with an average error of 3%/6% for reader 1/reader 2, respectively. In patients, across all subjective categories and both readers, 40 keV QIR-3 and QIR-4 images received the best scores (p < 0.001). CONCLUSION Forty keV VMI with QIR-4 significantly improved image quality of CCTA with PCD-CT. ADVANCES IN KNOWLEDGE PCD-CT at 40 keV and QIR-4 improves image quality of CCTA.
Collapse
Affiliation(s)
| | | | - Victor Mergen
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - André Euler
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
12
|
Dabli D, Loisy M, Frandon J, de Oliveira F, Meerun AM, Guiu B, Beregi JP, Greffier J. Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study. Eur Radiol Exp 2023; 7:1. [PMID: 36617620 PMCID: PMC9826773 DOI: 10.1186/s41747-022-00314-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Accepted: 11/05/2022] [Indexed: 01/10/2023] Open
Abstract
BACKGROUND To assess the impact of the new version of a deep learning (DL) spectral reconstruction on image quality of virtual monoenergetic images (VMIs) for contrast-enhanced abdominal computed tomography in the rapid kV-switching platform. METHODS Two phantoms were scanned with a rapid kV-switching CT using abdomen-pelvic CT examination parameters at dose of 12.6 mGy. Images were reconstructed using two versions of DL spectral reconstruction algorithms (DLSR V1 and V2) for three reconstruction levels. The noise power spectrum (NSP) and task-based transfer function at 50% (TTF50) were computed at 40/50/60/70 keV. A detectability index (d') was calculated for enhanced lesions at low iodine concentrations: 2, 1, and 0.5 mg/mL. RESULTS The noise magnitude was significantly lower with DLSR V2 compared to DLSR V1 for energy levels between 40 and 60 keV by -36.5% ± 1.4% (mean ± standard deviation) for the standard level. The average NPS frequencies increased significantly with DLSR V2 by 23.7% ± 4.2% for the standard level. The highest difference in TTF50 was observed at the mild level with a significant increase of 61.7% ± 11.8% over 40-60 keV energy with DLSR V2. The d' values were significantly higher for DLSR V2 versus DLSR V1. CONCLUSIONS The DLSR V2 improves image quality and detectability of low iodine concentrations in VMIs compared to DLSR V1. This suggests a great potential of DLSR V2 to reduce iodined contrast doses.
Collapse
Affiliation(s)
- Djamel Dabli
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
| | - Maeliss Loisy
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Julien Frandon
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Fabien de Oliveira
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Azhar Mohamad Meerun
- grid.157868.50000 0000 9961 060XSaint-Eloi University Hospital, Montpellier, France
| | - Boris Guiu
- grid.157868.50000 0000 9961 060XSaint-Eloi University Hospital, Montpellier, France
| | - Jean-Paul Beregi
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| | - Joël Greffier
- Department of Medical Imaging, IMAGINE UR UM 103, Montpellier University, Nîmes University Hospital, Bd Prof Robert Debré, 30029 Nîmes Cedex 9, France
| |
Collapse
|
13
|
Radiomics-Based Machine Learning for Predicting the Injury Time of Rib Fractures in Gemstone Spectral Imaging Scans. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010008. [PMID: 36671582 PMCID: PMC9855073 DOI: 10.3390/bioengineering10010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
This retrospective study aimed to predict the injury time of rib fractures in distinguishing fresh (30 days) or old (90 days) rib fractures. We enrolled 111 patients with chest trauma who had been scanned for rib fractures at our hospital between January 2018 and December 2018 using gemstone spectral imaging (GSI). The volume of interest of each broken end of the rib fractures was segmented using calcium-based material decomposition images derived from the GSI scans. The training and testing sets were randomly assigned in a 7:3 ratio. All cases were divided into groups distinguishing the injury time at 30 and 90 days. We constructed radiomics-based models to predict the injury time of rib fractures. The model performance was assessed by the area under the curve (AUC) obtained by the receiver operating characteristic analysis. We included 54 patients with 259 rib fracture segmentations (34 men; mean age, 52 years ± 12.02; and range, 19-72 years). Nine features were excluded by the least absolute shrinkage and selection operator logistic regression to build the radiomics signature. For distinguishing the injury time at 30 days, the Support Vector Machine (SVM) model and human-model collaboration resulted in an accuracy and AUC of 0.85 and 0.871 and 0.91 and 0.912, respectively, and 0.81 and 0.804 and 0.83 and 0.85, respectively, at 90 days in the testing set. The radiomics-based model displayed good accuracy in differentiating between the injury time of rib fractures at 30 and 90 days, and the human-model collaboration generated more accurate outcomes, which may help to add value to clinical practice and distinguish artificial injury in forensic medicine.
Collapse
|
14
|
Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging 2022; 104:167-177. [PMID: 36414506 DOI: 10.1016/j.diii.2022.11.003] [Citation(s) in RCA: 61] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 11/11/2022] [Indexed: 11/21/2022]
Abstract
Spectral computed tomography (CT) imaging encompasses a unique generation of CT systems based on a simple principle that makes use of the energy-dependent information present in CT images. Over the past two decades this principle has been expanded with the introduction of dual-energy CT systems. The first generation of spectral CT systems, represented either by dual-source or dual-layer technology, opened up a new imaging approach in the radiology community with their ability to overcome the limitations of tissue characterization encountered with conventional CT. Its expansion worldwide can also be considered as an important leverage for the recent groundbreaking technology based on a new chain of detection available on photon counting CT systems, which holds great promise for extending CT towards multi-energy CT imaging. The purpose of this article was to detail the basic principles and techniques of spectral CT with a particular emphasis on the newest technical developments of dual-energy and multi-energy CT systems.
Collapse
|
15
|
Zorzetto G, Coppola A, Molinelli V, Angeretti MG, Casarin J, Fontana F, Piacentino F, Carcano G, Ghezzi F, Venturini M. Spectral CT in peritoneal carcinomatosis from ovarian cancer: a tool for differential diagnosis of small nodules? Eur Radiol Exp 2022; 6:45. [PMID: 36245001 PMCID: PMC9573836 DOI: 10.1186/s41747-022-00302-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 08/04/2022] [Indexed: 01/17/2023] Open
Abstract
The detection of peritoneal carcinomatosis in patients with ovarian cancer is crucial to establish the correct therapeutic planning (debulking surgery versus neoadjuvant chemotherapy). Often, however, the nodules of peritoneal carcinomatosis are very small in size or have a reticular appearance that can mimic the fat stranding that is typical of acute inflammation conditions. Our hypothesis is that the use of dual-layer spectral computed tomography with its applications, such as virtual monoenergetic imaging and Z-effective imaging, might improve the detection and the characterisation of peritoneal nodules, increasing sensitivity and diagnostic accuracy, as recently described for other oncological diseases.
Collapse
|