1
|
Chen W, Lim LJR, Lim RQR, Yi Z, Huang J, He J, Yang G, Liu B. Artificial intelligence powered advancements in upper extremity joint MRI: A review. Heliyon 2024; 10:e28731. [PMID: 38596104 PMCID: PMC11002577 DOI: 10.1016/j.heliyon.2024.e28731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 03/21/2024] [Accepted: 03/22/2024] [Indexed: 04/11/2024] Open
Abstract
Magnetic resonance imaging (MRI) is an indispensable medical imaging examination technique in musculoskeletal medicine. Modern MRI techniques achieve superior high-quality multiplanar imaging of soft tissue and skeletal pathologies without the harmful effects of ionizing radiation. Some current limitations of MRI include long acquisition times, artifacts, and noise. In addition, it is often challenging to distinguish abutting or closely applied soft tissue structures with similar signal characteristics. In the past decade, Artificial Intelligence (AI) has been widely employed in musculoskeletal MRI to help reduce the image acquisition time and improve image quality. Apart from being able to reduce medical costs, AI can assist clinicians in diagnosing diseases more accurately. This will effectively help formulate appropriate treatment plans and ultimately improve patient care. This review article intends to summarize AI's current research and application in musculoskeletal MRI, particularly the advancement of DL in identifying the structure and lesions of upper extremity joints in MRI images.
Collapse
Affiliation(s)
- Wei Chen
- Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Lincoln Jian Rong Lim
- Department of Medical Imaging, Western Health, Footscray Hospital, Victoria, Australia
- Department of Surgery, The University of Melbourne, Victoria, Australia
| | - Rebecca Qian Ru Lim
- Department of Hand & Reconstructive Microsurgery, Singapore General Hospital, Singapore
| | - Zhe Yi
- Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| | - Jiaxing Huang
- Institute of Automation, Chinese Academy of Sciences, Beijing, China
- School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing, China
| | - Jia He
- Institute of Automation, Chinese Academy of Sciences, Beijing, China
- School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing, China
| | - Ge Yang
- Institute of Automation, Chinese Academy of Sciences, Beijing, China
- School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing, China
| | - Bo Liu
- Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
2
|
Sneag DB, Abel F, Potter HG, Fritz J, Koff MF, Chung CB, Pedoia V, Tan ET. MRI Advancements in Musculoskeletal Clinical and Research Practice. Radiology 2023; 308:e230531. [PMID: 37581501 PMCID: PMC10477516 DOI: 10.1148/radiol.230531] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 06/01/2023] [Accepted: 06/07/2023] [Indexed: 08/16/2023]
Abstract
Over the past decades, MRI has become increasingly important for diagnosing and longitudinally monitoring musculoskeletal disorders, with ongoing hardware and software improvements aiming to optimize image quality and speed. However, surging demand for musculoskeletal MRI and increased interest to provide more personalized care will necessitate a stronger emphasis on efficiency and specificity. Ongoing hardware developments include more powerful gradients, improvements in wide-bore magnet designs to maintain field homogeneity, and high-channel phased-array coils. There is also interest in low-field-strength magnets with inherently lower magnetic footprints and operational costs to accommodate global demand in middle- and low-income countries. Previous approaches to decrease acquisition times by means of conventional acceleration techniques (eg, parallel imaging or compressed sensing) are now largely overshadowed by deep learning reconstruction algorithms. It is expected that greater emphasis will be placed on improving synthetic MRI and MR fingerprinting approaches to shorten overall acquisition times while also addressing the demand of personalized care by simultaneously capturing microstructural information to provide greater detail of disease severity. Authors also anticipate increased research emphasis on metal artifact reduction techniques, bone imaging, and MR neurography to meet clinical needs.
Collapse
Affiliation(s)
- Darryl B. Sneag
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Frederik Abel
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Hollis G. Potter
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Jan Fritz
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Matthew F. Koff
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Christine B. Chung
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Valentina Pedoia
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| | - Ek T. Tan
- From the Department of Radiology and Imaging, Hospital for Special
Surgery, 535 E 70th St, New York, NY 10021 (D.B.S., F.A., H.G.P., M.F.K.,
E.T.T.); Department of Radiology, New York University Grossman School of
Medicine, New York, NY (J.F.); Department of Radiology, University of California
San Diego, La Jolla, Calif (C.B.C.); Radiology Service, Veterans Affairs San
Diego Healthcare System, La Jolla, Calif (C.B.C.); and Department of Radiology
and Biomedical Imaging, University of California San Francisco, San Francisco,
Calif (V.P.)
| |
Collapse
|
3
|
Wessling D, Herrmann J, Afat S, Nickel D, Othman AE, Almansour H, Gassenmaier S. Reduction in Acquisition Time and Improvement in Image Quality in T2-Weighted MR Imaging of Musculoskeletal Tumors of the Extremities Using a Novel Deep Learning-Based Reconstruction Technique in a Turbo Spin Echo (TSE) Sequence. Tomography 2022; 8:1759-1769. [PMID: 35894013 PMCID: PMC9326558 DOI: 10.3390/tomography8040148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 06/23/2022] [Accepted: 06/30/2022] [Indexed: 11/23/2022] Open
Abstract
Background: The aim of this study was to assess the technical feasibility and the impact on image quality and acquisition time of a deep learning-accelerated fat-saturated T2-weighted turbo spin echo sequence in musculoskeletal imaging of the extremities. Methods: Twenty-three patients who underwent MRI of the extremities were prospectively included. Standard T2w turbo inversion recovery magnitude (TIRMStd) imaging was compared to a deep learning-accelerated T2w TSE (TSEDL) sequence. Image analysis of 23 patients with a mean age of 60 years (range 30−86) was performed regarding image quality, noise, sharpness, contrast, artifacts, lesion detectability and diagnostic confidence. Pathological findings were documented measuring the maximum diameter. Results: The analysis showed a significant improvement for the T2 TSEDL with regard to image quality, noise, contrast, sharpness, lesion detectability, and diagnostic confidence, as compared to T2 TIRMStd (each p < 0.001). There were no differences in the number of detected lesions. The time of acquisition (TA) could be reduced by 52−59%. Interrater agreement was almost perfect (κ = 0.886). Conclusion: Accelerated T2 TSEDL was technically feasible and superior to conventionally applied T2 TIRMStd. Concurrently, TA could be reduced by 52−59%. Therefore, deep learning-accelerated MR imaging is a promising and applicable method in musculoskeletal imaging.
Collapse
Affiliation(s)
- Daniel Wessling
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany; (D.W.); (J.H.); (H.A.); (S.G.)
| | - Judith Herrmann
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany; (D.W.); (J.H.); (H.A.); (S.G.)
| | - Saif Afat
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany; (D.W.); (J.H.); (H.A.); (S.G.)
- Correspondence:
| | - Dominik Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, 91052 Erlangen, Germany;
| | - Ahmed E. Othman
- Department of Diagnostic and Interventional Neuroradiology, University Hospital of Mainz, 55131 Mainz, Germany;
| | - Haidara Almansour
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany; (D.W.); (J.H.); (H.A.); (S.G.)
| | - Sebastian Gassenmaier
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany; (D.W.); (J.H.); (H.A.); (S.G.)
| |
Collapse
|
4
|
Emanuel KS, Kellner LJ, Peters MJM, Haartmans MJJ, Hooijmans MT, Emans PJ. The relation between the biochemical composition of knee articular cartilage and quantitative MRI: a systematic review and meta-analysis. Osteoarthritis Cartilage 2022; 30:650-662. [PMID: 34826570 DOI: 10.1016/j.joca.2021.10.016] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Early and non-invasive detection of osteoarthritis (OA) is required to enable early treatment and monitoring of interventions. Some of the earliest signs of OA are the change in proteoglycan and collagen composition. The aim of this study is to establish the relations between quantitative magnetic resonance imaging (MRI) and biochemical concentration and organization in knee articular cartilage. METHODS A preregistered systematic literature review was performed using the databases PubMed and Embase. Papers were included if quantitative MRI and a biochemical assay or polarized light microscopy (PLM) was performed on knee articular cartilage, and a quantified correlation was described. The extracted correlations were pooled using a random effects model. RESULTS 21 papers were identified. The strongest pooled correlation was found for delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) vs proteoglycan concentration (r = 0.59). T1ρ relaxation times are inversely correlated to proteoglycan concentration (r = -0.54). A weak correlation between T2 relaxation times and proteoglycans was found (r = -0.38). No correlation between T2 relaxation time and collagen concentration was found (r = -0.02). A heterogeneous set of correlations between T2 relaxation times and PLM were identified, including strong correlations to anisotropy. CONCLUSION DGEMRIC measures are significantly correlated to proteoglycan concentration. The needed contrast agent is however a disadvantage; the T1ρ sequence was found as a non-invasive alternative. Remarkably, no correlation was found between T2 relaxation times and collagen concentration. T2 relaxation times is related to organization, rather than concentration of collagen fibers. PROSPERO ID CRD42020168337.
Collapse
Affiliation(s)
- K S Emanuel
- Department of Orthopedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Center+, Maastricht, the Netherlands; Amsterdam UMC, University of Amsterdam, Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam, the Netherlands.
| | - L J Kellner
- Department of Orthopedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Center+, Maastricht, the Netherlands.
| | - M J M Peters
- Department of Orthopedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Center+, Maastricht, the Netherlands.
| | - M J J Haartmans
- Department of Orthopedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Center+, Maastricht, the Netherlands.
| | - M T Hooijmans
- Amsterdam UMC, University of Amsterdam, Department of Biomedical Engineering and Physics, Amsterdam Movement Sciences, Amsterdam, the Netherlands.
| | - P J Emans
- Department of Orthopedic Surgery, CAPHRI Care and Public Health Research Institute, Maastricht University Medical Center+, Maastricht, the Netherlands.
| |
Collapse
|
5
|
Utility of 3T MRI in Women with IB1 Cervical Cancer in Determining the Necessity of Less Invasive Surgery. Cancers (Basel) 2022; 14:cancers14010224. [PMID: 35008388 PMCID: PMC8750208 DOI: 10.3390/cancers14010224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/16/2021] [Accepted: 12/17/2021] [Indexed: 11/17/2022] Open
Abstract
PURPOSE Cervical cancer that is invisible on magnetic resonance imaging (MRI) may suggest lower tumor burden than physical examination. Recently, 3 tesla (3T) MRI has been widely used prior to surgery because of its higher resolution than 1.5T MRI. The aim was to retrospectively evaluate the utility of 3T MRI in women with early cervical cancer in determining the necessity of less invasive surgery. MATERIALS AND METHODS Between January 2010 and December 2015, a total of 342 women with FIGO stage IB1 cervical cancer underwent 3T MRI prior to radical hysterectomy, vaginectomy, and lymph node dissection. These patients were classified into cancer-invisible (n = 105) and cancer-visible (n = 237) groups based on the 3T MRI findings. These groups were compared regarding pathologic parameters and long-term survival rates. RESULTS The cancer sizes of the cancer-invisible versus cancer-visible groups were 11.5 ± 12.2 mm versus 30.1 ± 16.2 mm, respectively (p < 0.001). The depths of stromal invasion in these groups were 20.5 ± 23.6% versus 63.5 ± 31.2%, respectively (p < 0.001). Parametrial invasion was 0% (0/105) in the cancer-invisible group and 21.5% (51/237) in the cancer-visible group (odds ratio = 58.3, p < 0.001). Lymph node metastasis and lymphovascular space invasion were 5.9% (6/105) versus 26.6% (63/237) (5.8, p < 0.001) and 11.7% (12/105) versus 40.1% (95/237) (5.1, p < 0.001), respectively. Recurrence-free and overall 5-year survival rates were 99.0% (104/105) versus 76.8% (182/237) (p < 0.001) and 98.1% (103/105) versus 87.8% (208/237) (p = 0.003), respectively. CONCLUSIONS 3T MRI can play a great role in determining the necessity of parametrectomy in women with IB1 cervical cancer. Therefore, invisible cervical cancer on 3T MRI will be a good indicator for less invasive surgery.
Collapse
|
6
|
Platt T, Ladd ME, Paech D. 7 Tesla and Beyond: Advanced Methods and Clinical Applications in Magnetic Resonance Imaging. Invest Radiol 2021; 56:705-725. [PMID: 34510098 PMCID: PMC8505159 DOI: 10.1097/rli.0000000000000820] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 08/07/2021] [Accepted: 08/07/2021] [Indexed: 12/15/2022]
Abstract
ABSTRACT Ultrahigh magnetic fields offer significantly higher signal-to-noise ratio, and several magnetic resonance applications additionally benefit from a higher contrast-to-noise ratio, with static magnetic field strengths of B0 ≥ 7 T currently being referred to as ultrahigh fields (UHFs). The advantages of UHF can be used to resolve structures more precisely or to visualize physiological/pathophysiological effects that would be difficult or even impossible to detect at lower field strengths. However, with these advantages also come challenges, such as inhomogeneities applying standard radiofrequency excitation techniques, higher energy deposition in the human body, and enhanced B0 field inhomogeneities. The advantages but also the challenges of UHF as well as promising advanced methodological developments and clinical applications that particularly benefit from UHF are discussed in this review article.
Collapse
Affiliation(s)
- Tanja Platt
- From the Medical Physics in Radiology, German Cancer Research Center (DKFZ)
| | - Mark E. Ladd
- From the Medical Physics in Radiology, German Cancer Research Center (DKFZ)
- Faculty of Physics and Astronomy
- Faculty of Medicine, University of Heidelberg, Heidelberg
- Erwin L. Hahn Institute for MRI, University of Duisburg-Essen, Essen
| | - Daniel Paech
- Division of Radiology, German Cancer Research Center (DKFZ), Heidelberg
- Clinic for Neuroradiology, University of Bonn, Bonn, Germany
| |
Collapse
|
7
|
von Deuster C, Sommer S, Germann C, Hinterholzer N, Heidemann RM, Sutter R, Nanz D. Controlling Through-Slice Chemical-Shift Artifacts for Improved Non-Fat-Suppressed Musculoskeletal Turbo-Spin-Echo Magnetic Resonance Imaging at 7 T. Invest Radiol 2021; 56:545-552. [PMID: 33813573 DOI: 10.1097/rli.0000000000000778] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES Through-slice chemical shift artifacts in state-of-the-art turbo-spin-echo (TSE) images can be significantly more severe at 7 T than at lower field strengths. In musculoskeletal applications, these artifacts appear similar to bone fractures or neoplastic bone marrow disease. The objective of this work was to explore and reduce through-slice chemical shift artifacts in 2-dimensional (2D) TSE imaging at 7 T. MATERIALS AND METHODS This prospective study was approved by the local ethics board. The bandwidths of the excitation and refocusing radiofrequency (RF) pulses of a prototype 2D TSE sequence were individually modified and their effect on the slice profiles and relative slice locations of water and fat spins was assessed in an oil-water phantom. Based on these results, it was hypothesized that the combination of matched and increased excitation and refocusing RF pulse bandwidths ("MIB") of 1500 Hz would enable 2D TSE imaging with significantly reduced chemical shift artifacts compared with a state-of-the-art sequence with unmatched and moderate RF pulse bandwidths ("UMB") of 1095 and 682 Hz.A series of T1-weighted sagittal knee examinations in 10 healthy human subjects were acquired using the MIB and UMB sequences and independently evaluated by 2 radiologists. They measured the width of chemical shift artifacts at 2 standardized locations and graded the perceived negative effect of chemical shift artifacts on image quality in the bones and in the whole gastrocnemius muscle on a 5-point scale. Similar knee, wrist, and foot images were acquired in a single subject. Signal-to-noise ratios in the femoral bone marrow were computed between the UMB and MIB sequences. RESULTS Phantom measurements confirmed the expected spatial separation of simultaneously affected water and fat slices between 40% and 200% of the prescribed slice thickness for RF pulse bandwidths between 2500 and 500 Hz. Through-slice chemical shift artifacts at the bone-cartilage interface were significantly smaller with MIB than with UMB (location 1: 0.35 ± 0.20 mm vs 1.27 ± 0.27 mm, P < 0.001; location 2: 0.25 ± 0.13 mm vs 1.48 ± 0.46 mm, P < 0.001; intraclass correlation coefficient = 0.98). The negative effect of chemical shift artifacts on image quality was significantly smaller with MIB than with UMB (bone: 2 ± 0 vs 4 ± 1, P < 0.004 [both readers]; muscle: 3 ± 0 vs 2 ± 0, P < 0.004 [both readers]; κ = 0.69). The signal-to-noise ratio of the UMB and MIB sequences was comparable, with a ratio of 99 ± 7%. Images acquired using the UMB sequence displayed numerous artifactual hyperintensities and diffuse, as well as locally severe, fat signal loss in all examined regions, whereas the MIB sequence consistently yielded high image quality with bright T1-weighted fat signal and excellent depiction of fine tissue structures. CONCLUSIONS On 7 T systems, the selection of high and matched RF bandwidths for excitation and refocusing pulses for 2D TSE imaging without fat suppression showed consistently better image quality than state-of-the-art sequences with unmatched lower RF pulse bandwidths.
Collapse
Affiliation(s)
| | | | | | - Natalie Hinterholzer
- SCMI, Swiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland
| | | | | | | |
Collapse
|
8
|
Park BK, Kim TJ. Useful MRI Findings for Minimally Invasive Surgery for Early Cervical Cancer. Cancers (Basel) 2021; 13:cancers13164078. [PMID: 34439231 PMCID: PMC8391577 DOI: 10.3390/cancers13164078] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 08/04/2021] [Accepted: 08/08/2021] [Indexed: 01/02/2023] Open
Abstract
Simple Summary Radical hysterectomy and lymph node dissection are extensive procedures with severe post-operative morbidities and should be avoided on patients with low risk of recurrence. Still, due to lack of good prognostic tools, radical surgery is performed on most patients with early stage cervical cancer, leading to overtreatment and unnecessary morbidities. The recent International Federation of Gynecology and Obstetrics (FIGO) staging system accepts the use of magnetic resonance imaging (MRI) in addition to physical examination. Currently, 3 Tesla (3T) MRI is available widely and, due to its high soft tissue contrast, can provide more useful information on precise estimation of tumor size and metastasis than can physical examination in patients with cervical cancer. Therefore, this imaging modality can help gynecologic oncologists to determine whether minimally invasive surgery is necessary and can be used for early detection of small recurrent cancers. Abstract According to the recent International Federation of Gynecology and Obstetrics (FIGO) staging system, Stage III cervical cancer indicates pelvic or paraaortic lymph node metastasis. Accordingly, the new FIGO stage accepts imaging modalities, such as MRI, as part of the FIGO 2018 updated staging. Magnetic resonance imaging (MRI) is the best imaging modality to estimate the size or volume of uterine cancer because of its excellent soft tissue contrast. As a result, MRI is being used increasingly to determine treatment options and follow-up for cervical cancer patients. Increasing availability of cancer screening and vaccination have improved early detection of cervical cancer. However, the incidence of early cervical cancers has increased compared to that of advanced cervical cancer. A few studies have investigated if MRI findings are useful in management of early cervical cancer. MRI can precisely predict tumor burden, allowing conization, trachelectomy, and simple hysterectomy to be considered as minimally invasive treatment options for early cervical cancer. This imaging modality also can be used to determine whether there is recurrent cancer following minimally invasive treatments. The purpose of this review is to highlight useful MRI features for managing women with early cervical cancer.
Collapse
Affiliation(s)
- Byung Kwan Park
- Department of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul 06351, Korea
- Correspondence: (B.K.P.); (T.-J.K.); Tel.: +82-2-3410-6457 (B.K.P.); +82-2-3410-0630 (T.-J.K.)
| | - Tae-Joong Kim
- Department of Obstetrics & Gynecology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul 06351, Korea
- Correspondence: (B.K.P.); (T.-J.K.); Tel.: +82-2-3410-6457 (B.K.P.); +82-2-3410-0630 (T.-J.K.)
| |
Collapse
|
9
|
Götestrand S, Björkman A, Björkman-Burtscher IM, Kristiansson I, Aksyuk E, Szaro P, Markenroth Bloch K, Geijer M. Visualization of wrist anatomy-a comparison between 7T and 3T MRI. Eur Radiol 2021; 32:1362-1370. [PMID: 34378077 PMCID: PMC8795032 DOI: 10.1007/s00330-021-08165-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 06/16/2021] [Accepted: 06/24/2021] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Injuries to the wrist are, due to its small size and complex anatomical structures, difficult to assess by MR, and surgical interventions such as diagnostic arthroscopy are often necessary. Therefore, improved visualization using non-invasive methods could be of clinical value. As a first step of improvement, the purpose of this study was to evaluate visualization of anatomical structures at 7T compared with 3T MR. METHODS Eighteen healthy volunteers (three males and three females from each age decade between 20 and 49 years) were examined with 7T and 3T MR. Four musculoskeletal radiologists graded 2D and 3D images on a five-level grading scale for visibility of ligaments, cartilage, nerves, trabecular bone, and tendons, as well as overall image quality (i.e., edge sharpness, perceived tissue contrast, and presence of artefacts). Statistical analysis was done using a visual grading characteristics (VGC) analysis. RESULTS Visibility of cartilage, trabecular bone, tendons, nerves, and ligaments was graded significantly higher at 7T with an area under the curve (AUCVGC) of 0.62-0.88 (95% confidence interval [CI] 0.50-0.97, p = < 0.0001-0.03) using either 2D or 3D imaging. Imaging with 3T was not graded as superior to 7T for any structure. Image quality was also significantly superior at 7T, except for artefacts, where no significant differences were found. CONCLUSIONS Tendons, trabecular bone, nerves, and ligaments were all significantly better visualized at 7T compared to 3T. KEY POINTS • MRI of the wrist at 7T with a commercially available wrist coil is feasible at similar acquisition times as for 3T MRI. • The current study showed 7T to be superior to 3T in the visualization of anatomical structures of the wrist, including ligaments, tendons, nerves, and trabecular bone. • Image quality was significantly superior at 7T, except for artefacts, where no significant differences were found.
Collapse
Affiliation(s)
- Simon Götestrand
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden. .,Department of Clinical Sciences, Faculty of Medicine, Lund University, Lund, Sweden.
| | - Anders Björkman
- Department of Hand Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg, Sweden
| | - Isabella M Björkman-Burtscher
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Radiology, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg, Sweden
| | - Ingvar Kristiansson
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden
| | - Elenya Aksyuk
- Department of Medical Imaging and Physiology, Skåne University Hospital, Lund, Sweden.,Department of Clinical Sciences, Faculty of Medicine, Lund University, Lund, Sweden
| | - Pawel Szaro
- Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | | | - Mats Geijer
- Department of Clinical Sciences, Faculty of Medicine, Lund University, Lund, Sweden.,Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Radiology, Sahlgrenska University Hospital, Region Västra Götaland, Gothenburg, Sweden
| |
Collapse
|
10
|
Germann C, Sutter R, Nanz D. Novel observations of Pacinian corpuscle distribution in the hands and feet based on high-resolution 7-T MRI in healthy volunteers. Skeletal Radiol 2021; 50:1249-1255. [PMID: 33156397 PMCID: PMC8035111 DOI: 10.1007/s00256-020-03667-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 10/23/2020] [Accepted: 11/01/2020] [Indexed: 02/02/2023]
Abstract
Pacinian corpuscles represent special nerve endings that serve as mechanoreceptors sensitive to vibration and pressure and are crucial for proprioception. This work demonstrates that the complex network of Pacinian corpuscles in hands and feet can be examined with three-dimensional Dual Echo Steady State (DESS) MR imaging at 7 T, while previous dedicated MRI reports were either limited to two-dimensional images or focused on the hands. The high-resolution MR images show the detailed architecture of the complex receptor network and reveal a "chain-like" arrangement of Pacinian corpuscles, a predilection for clustering around metacarpophalangeal/metatarsophalangeal joints, proximal phalanges and fingertips, and specific sensor locations both in the superficial subcutaneous tissue and adjacent to deep soft tissue structures such as tendons and joint capsules.
Collapse
Affiliation(s)
- Christoph Germann
- Radiology, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zurich, Switzerland.
- University of Zurich, Zurich, Switzerland.
| | - Reto Sutter
- Radiology, Balgrist University Hospital, Forchstrasse 340, CH-8008, Zurich, Switzerland
- University of Zurich, Zurich, Switzerland
| | - Daniel Nanz
- University of Zurich, Zurich, Switzerland
- SCMI, Swiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Zurich, Switzerland
| |
Collapse
|
11
|
Abstract
Regulatory approval of ultrahigh field (UHF) MR imaging scanners for clinical use has opened new opportunities for musculoskeletal imaging applications. UHF MR imaging has unique advantages in terms of signal-to-noise ratio, contrast-to-noise ratio, spectral resolution, and multinuclear applications, thus providing unique information not available at lower field strengths. But UHF also comes with a set of technical challenges that are yet to be resolved and may not be suitable for all imaging applications. This review focuses on the latest research in musculoskeletal MR imaging applications at UHF including morphologic imaging, T2, T2∗, and T1ρ mapping, chemical exchange saturation transfer, sodium imaging, and phosphorus spectroscopy imaging applications.
Collapse
|
12
|
Ahlander BM, Engvall J, Ericsson E. Anxiety during magnetic resonance imaging of the spine in relation to scanner design and size. Radiography (Lond) 2020; 26:110-116. [PMID: 32052788 DOI: 10.1016/j.radi.2019.09.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 09/06/2019] [Accepted: 09/09/2019] [Indexed: 12/27/2022]
Abstract
INTRODUCTION Magnetic resonance imaging in closed-bore scanners sometimes provokes anxiety but closed-bore designs have gradually become wider and shorter. Open scanners may be easier to tolerate. The aim was to compare patient anxiety during MRI between bore diameters of 60 cm and 70 cm, and to determine the current level of patient anxiety and experience in open scanners in a clinical setrting. METHODS Consecutive patients referred for examination of the spine in 60 cm and 70 cm bores and one open scanner participated. Four established/validated questionnaires, answered before, directly after (N = 155) and one week after (N = 109) the MRI-examination were used, measuring anxiety, fear and depression. RESULTS No difference was found in the patient scores of anxiety between the 60 cm and the 70 cm scanners on the examination day. At follow-up, patients in the 70 cm bore rated their examination experience better (p < 0.025), compared to patients in the 60 cm bore. Patients in the open scanner rated higher levels of anxiety (p < 0.001) before, directly after and one week after the examination, compared to the closed bore scanners. CONCLUSION Scanners with a 70 cm diameter bore seem more tolerable than those with a 60 cm bore. Patients referred to the open scanner had on average a higher tendency to express anxiety. Still, patient anxiety in MRI is challenging and further research required. IMPLICATIONS FOR PRACTICE Patients prefer to be examined in 70 cm bore scanners compared with 60 cm. If open scanners aren't available extended support may be necessary for the most anxious patients.
Collapse
Affiliation(s)
- B M Ahlander
- Ryhov County Hospital, SE-551 85 Jönköping, Sweden.
| | - J Engvall
- Department of Clinical Physiology, Linköping University, SE-581 83 Linköping, Sweden; Center of Medical Image Science and Visualization, Linköping University, SE-581 83 Linköping, Sweden.
| | - E Ericsson
- Faculty of Medicine and Health, School of Health Science, Örebro University, SE-701 82 Örebro, Sweden.
| |
Collapse
|
13
|
Durastanti G, Leardini A, Siegler S, Durante S, Bazzocchi A, Belvedere C. Comparison of cartilage and bone morphological models of the ankle joint derived from different medical imaging technologies. Quant Imaging Med Surg 2019; 9:1368-1382. [PMID: 31559166 DOI: 10.21037/qims.2019.08.08] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Background Accurate geometrical models of bones and cartilage are necessary in biomechanical modelling of human joints, and in planning and designing of joint replacements. Image-based subject-specific model development requires image segmentation, spatial filtering and 3-dimensional rendering. This is usually based on computed tomography (CT) for bone models, on magnetic resonance imaging (MRI) for cartilage models. This process has been reported extensively in the past, but no studies have ever compared the accuracy and quality of these models when obtained also by merging different imaging modalities. The scope of the present work is to provide this comparative analysis in order to identify optimal imaging modality and registration techniques for producing 3-dimensional bone and cartilage models of the ankle joint. Methods One cadaveric leg was instrumented with multimodal markers and scanned using five different imaging modalities: a standard, a dual-energy and a cone-beam CT (CBCT) device, and a 1.5 and 3.0 Tesla MRI devices. Bone, cartilage, and combined bone and cartilage models were produced from each of these imaging modalities, and registered in space according to matching model surfaces or to corresponding marker centres. To assess the quality in overall model reconstruction, distance map analyses were performed and the difference between model surfaces obtained from the different imaging modalities and registration techniques was measured. Results The registration between models worked better with model surface matching than corresponding marker positions, particularly with MRI. The best bone models were obtained with the CBCT. Models with cartilage were defined better with the 3.0 Tesla than the 1.5 Tesla. For the combined bone and cartilage models, the colour maps and the numerical results from distance map analysis (DMA) showed that the smallest distances and the largest homogeneity were obtained from the CBCT and the 3.0 T MRI via model surface registration. Conclusions These observations are important in producing accurate bone and cartilage models from medical imaging and relevant for applications such as designing of custom-made ankle replacements or, more in general, of implants for total as well as focal joint replacements.
Collapse
Affiliation(s)
- Gilda Durastanti
- Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Alberto Leardini
- Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Sorin Siegler
- Department of Mechanical Engineering and Mechanics, Drexel University, Philadelphia, PA, USA
| | - Stefano Durante
- Nursing, Technical and Rehabilitation Assistance Service, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Alberto Bazzocchi
- Diagnostic and Interventional Radiology, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Claudio Belvedere
- Movement Analysis Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
14
|
Chebrolu VV, Kollasch PD, Deshpande V, Grinstead J, Howe BM, Frick MA, Fagan AJ, Benner T, Heidemann RM, Felmlee JP, Amrami KK. Uniform combined reconstruction of multichannel 7T knee MRI receive coil data without the use of a reference scan. J Magn Reson Imaging 2019; 50:1534-1544. [PMID: 30779475 DOI: 10.1002/jmri.26691] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 02/07/2019] [Accepted: 02/07/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND MR image intensity nonuniformity is often observed at 7T. Reference scans from the body coil used for uniformity correction at lower field strengths are typically not available at 7T. PURPOSE To evaluate the efficacy of a novel algorithm, Uniform Combined Reconstruction (UNICORN), to correct receive coil-induced nonuniformity in musculoskeletal 7T MRI without the use of a reference scan. STUDY TYPE Retrospective image analysis study. SUBJECTS MRI data of 20 subjects was retrospectively processed offline. Field Strength/Sequence: Knees of 20 subjects were imaged at 7T with a single-channel transmit, 28-channel phased-array receive knee coil. A turbo-spin-echo sequence was used to acquire 33 series of images. ASSESSMENT Three fellowship-trained musculoskeletal radiologists with cumulative experience of 42 years reviewed the images. The uniformity, contrast, signal-to-noise ratio (SNR), and overall image quality were evaluated for images with no postprocessing, images processed with N4 bias field correction algorithm, and the UNICORN algorithm. STATISTICAL TESTS Intraclass correlation coefficient (ICC) was used for measuring the interrater reliability. ICC and 95% confidence intervals (CIs) were calculated using the R statistical package employing a two-way mixed-effects model based on a mean rating (k = 3) for absolute agreement. The Wilcoxon signed-rank test with continuity correction was used for analyzing the overall image quality scores. RESULTS UNICORN was preferred among the three methods evaluated for uniformity in 97.9% of the pooled ratings, with excellent interrater agreement (ICC of 0.98, CI 0.97-0.99). UNICORN was also rated better than N4 for contrast and equivalent to N4 in SNR with ICCs of 0.80 (CI 0.72-0.86) and 0.67 (CI 0.54-0.77), respectively. The overall image quality scores for UNICORN were significantly higher than N4 (P < 6 × 10-13 ), with good to excellent interrater agreement (ICC 0.90, CI 0.86-0.93). DATA CONCLUSION Without the use of a reference scan, UNICORN provides better image uniformity, contrast, and overall image quality at 7T compared with the N4 bias field-correction algorithm. LEVEL OF EVIDENCE 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1534-1544.
Collapse
Affiliation(s)
| | | | | | | | - Benjamin M Howe
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Matthew A Frick
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | - Andrew J Fagan
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | | | | - Joel P Felmlee
- Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA
| | | |
Collapse
|
15
|
Menon RG, Chang G, Regatte RR. The Emerging Role of 7 Tesla MRI in Musculoskeletal Imaging. CURRENT RADIOLOGY REPORTS 2018. [DOI: 10.1007/s40134-018-0286-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
16
|
Santini T, Kim J, Wood S, Krishnamurthy N, Farhat N, Maciel C, Raval SB, Zhao T, Ibrahim TS. A new RF transmit coil for foot and ankle imaging at 7T MRI. Magn Reson Imaging 2018; 45:1-6. [PMID: 28893660 PMCID: PMC5935253 DOI: 10.1016/j.mri.2017.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Revised: 09/05/2017] [Accepted: 09/05/2017] [Indexed: 12/31/2022]
Abstract
A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simulations performed on an anatomically detailed human lower leg model demonstrated an B1+ field distribution with a coefficient of variation (CV) of 23.9%/15.6%/28.8% and average B1+ of 0.33μT/0.56μT/0.43μT for 1W input power (i.e., 0.25W per channel) in the ankle/calcaneus/mid foot respectively. In-vivo B1+ mapping shows an average B1+ of 0.29μT over the entire foot/ankle. This newly developed RF coil also presents acceptable levels of average SAR (0.07W/kg for 10g per 1W of input power) and peak SAR (0.34W/kg for 10g per 1W of input power) over the whole lower leg. Preliminary in-vivo images in the foot/ankle were acquired using the T2-DESS MRI sequence without the use of a dedicated receive-only array.
Collapse
Affiliation(s)
- Tales Santini
- University of Pittsburgh, Department of Bioengineering, United States
| | - Junghwan Kim
- University of Pittsburgh, Department of Bioengineering, United States
| | - Sossena Wood
- University of Pittsburgh, Department of Bioengineering, United States
| | | | - Nadim Farhat
- University of Pittsburgh, Department of Bioengineering, United States
| | - Carlos Maciel
- University of Sao Paulo, Department of Electrical and Computer Engineering, Brazil
| | | | | | - Tamer S Ibrahim
- University of Pittsburgh, Department of Bioengineering, United States; University of Pittsburgh, Department of Radiology, United States.
| |
Collapse
|
17
|
Watts AE, Millar NL, Platt J, Kitson SM, Akbar M, Rech R, Griffin J, Pool R, Hughes T, McInnes IB, Gilchrist DS. MicroRNA29a Treatment Improves Early Tendon Injury. Mol Ther 2017; 25:2415-2426. [PMID: 28822690 DOI: 10.1016/j.ymthe.2017.07.015] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2017] [Revised: 07/25/2017] [Accepted: 07/25/2017] [Indexed: 01/21/2023] Open
Abstract
Tendon injuries (tendinopathies) are common in human and equine athletes and characterized by dysregulated collagen matrix, resulting in tendon damage. We have previously demonstrated a functional role for microRNA29a (miR29a) as a post-transcriptional regulator of collagen 3 expression in murine and human tendon injury. Given the translational potential, we designed a randomized, blinded trial to evaluate the potential of a miR29a replacement therapy as a therapeutic option to treat tendinopathy in an equine model that closely mimics human disease. Tendon injury was induced in the superficial digital flexor tendon (SDFT) of 17 horses. Tendon lesions were treated 1 week later with an intralesional injection of miR29a or placebo. miR29a treatment reduced collagen 3 transcript levels at week 2, with no significant changes in collagen 1. The relative lesion cross-sectional area was significantly lower in miR29a tendons compared to control tendons. Histology scores were significantly better for miR29a-treated tendons compared to control tendons. These data support the mechanism of microRNA-mediated modulation of early pathophysiologic events that facilitate tissue remodeling in the tendon after injury and provides a strong proof of principle that a locally delivered miR29a therapy improves early tendon healing.
Collapse
Affiliation(s)
- Ashlee E Watts
- The Comparative Orthopedics and Regenerative Medicine Laboratory, Texas A&M University, College Station, TX 77843, USA
| | - Neal L Millar
- Institute of Infection, Immunity, and Inflammation, College of Medicine, Veterinary, and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK.
| | - Josh Platt
- The Comparative Orthopedics and Regenerative Medicine Laboratory, Texas A&M University, College Station, TX 77843, USA
| | - Susan M Kitson
- Institute of Infection, Immunity, and Inflammation, College of Medicine, Veterinary, and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK
| | - Moeed Akbar
- Institute of Infection, Immunity, and Inflammation, College of Medicine, Veterinary, and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK
| | - Raquel Rech
- The Comparative Orthopedics and Regenerative Medicine Laboratory, Texas A&M University, College Station, TX 77843, USA
| | - Jay Griffin
- The Comparative Orthopedics and Regenerative Medicine Laboratory, Texas A&M University, College Station, TX 77843, USA
| | - Roy Pool
- The Comparative Orthopedics and Regenerative Medicine Laboratory, Texas A&M University, College Station, TX 77843, USA
| | - Tom Hughes
- Liphook Equine Hospital, Forest Mere, Liphook GU30 7JG, UK
| | - Iain B McInnes
- Institute of Infection, Immunity, and Inflammation, College of Medicine, Veterinary, and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK
| | - Derek S Gilchrist
- Institute of Infection, Immunity, and Inflammation, College of Medicine, Veterinary, and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK.
| |
Collapse
|
18
|
Badar F, Xia Y. Image interpolation improves the zonal analysis of cartilage T2 relaxation in MRI. Quant Imaging Med Surg 2017; 7:227-237. [PMID: 28516048 DOI: 10.21037/qims.2017.03.04] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND This project aimed to investigate the improvement in the detection of osteoarthritis (OA) in cartilage by the interpolation of T2 images, in the situation when the native MRI resolution is insufficient to resolve the depth-dependent T2 characteristics in articular cartilage (AC). METHODS Eighteen intact canine knee joints that were healthy or had mild (contralateral) or severe OA were T2-imaged in a 7T/20 cm MRI system at 200 µm/pixel resolution (macro-MRI). Two image analysis methods were used to interpolate the images to 100 µm/pixel, i.e., by Fourier-transforming the time-domain FID (Free Induction Decay) signal using the Varian NMR software and by interpolating the 2D T2 image using the ImageJ software. RESULTS The T2 profiles from 30 individual ROI of each healthy [6], mild [6] and OA [6] cartilage at 200 µm and the interpolated 100 µm resolutions were subdivided into two equal-thickness regions and three-equal thickness regions based on clinical MRI protocols. A new method divided the T2 profiles into three-unequal thickness zones according to the T2 profiles at 17.6 µm/pixel from the same cartilage imaged in a 7 Tesla/9 cm µMRI system. Both interpolation methods improved the depth-dependent T2 images/profiles in macro-MRI. The unequal zone division in T2 had better OA sensitivity than the equal zone division. The three-equal zone division of T2 profiles had better OA sensitivity than the two-equal zone division. The statistical significant difference between the healthy and mild OA cartilage is detected (P=0.0018) only by the unequal zone division method at 100 µm resolution. CONCLUSIONS Data interpolation improves the T2 sensitivity in MRI of cartilage OA. Unequal division of tissue thickness enables better early stage of OA detection than the equal division.
Collapse
Affiliation(s)
- Farid Badar
- Department of Physics and Center for Biomedical Research, Oakland University, Rochester, MI, USA
| | - Yang Xia
- Department of Physics and Center for Biomedical Research, Oakland University, Rochester, MI, USA
| |
Collapse
|