Fernández-Fairén M, Torres-Perez A, Perez R, Punset M, Molmeneu M, Ortiz-Hernández M, Manero JM, Gil J. Early Short-Term Postoperative Mechanical Failures of Current Ceramic-on-Ceramic Bearing Total Hip Arthroplasties. MATERIALS 2020; 13:ma13235318. [PMID: 33255355 PMCID: PMC7727787 DOI: 10.3390/ma13235318] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/19/2020] [Accepted: 11/20/2020] [Indexed: 12/01/2022]
Abstract
Although ceramic-on-ceramic (CoC) bearings have been shown to produce the smallest amount of wear volume in vitro as well as in vivo studies when used for total hip arthroplasties (THA), concerns about the failure of these bearing surfaces persist due to early failures observed after short postoperative time. In this study, an exhaustive analysis of the early failure occurred on the new generation of ceramic bearings, consisting of a composite alumina matrix-based material reinforced with yttria-stabilized tetragonal zirconia (Y-TZP) particles, chromium dioxide, and strontium crystals, was performed. For this study, 118 CoC bearings from 117 patients were revised. This article describes a group of mechanical failure CoC-bearing BIOLOX THA hip prosthesis patients without trauma history. The retrieved samples were observed under scanning electron microscopy (SEM), composition was analyzed with energy dispersive X-ray spectroscopy (EDX), and damaged surfaces were analyzed by grazing-incidence X-ray diffraction (GI-XRD) and white light interferometry. In the short term, CoC articulations provided similar mechanical behavior and functional outcome to those in XLPE cases. However, 5% more early mechanical failures cases were observed for the ceramic components. Although the fracture rate of third generation CoC couples is low, the present study shows the need to further improve the third generation of CoC-bearing couples for THA. Despite the improved wear compared to other materials, stress concentrators are sources of initial crack propagation, such as those found in the bore-trunnion areas. Moreover, in view of the evidence observed in this study, the chipping observed was due to the presence of monoclinic phase of the Y-TZP instead of tetragonal, which presents better mechanical properties. The results showed that total safety after receiving a THA is still a goal to be pursued.
Collapse
Affiliation(s)
- Mariano Fernández-Fairén
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
| | - Ana Torres-Perez
- Hospital Universitario Santa Lucía, Calle Mezquita, s/n, 30202 Cartagena, Spain;
| | - Roman Perez
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
| | - Miquel Punset
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
- UPC Innovation and Technology Center (CIT-UPC), Technical University of Catalonia (UPC), C. Jordi Girona 3–1, 08034 Barcelona, Spain
| | - Meritxell Molmeneu
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - Monica Ortiz-Hernández
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - José María Manero
- Biomaterials, Biomechanics and Tissue Engineering Group (BBT), Department of Materials Science and Engineering, Escola d’Enginyeria de Barcelona Est (EEBE), Universitat Politècnica de Catalunya (UPC), Carrer de Jordi Girona 1, 08034 Barcelona, Spain; (M.P.); (M.M.); (M.O.-H.); (J.M.M.)
- Barcelona Research Centre in Multiscale Science and Engineering, Technical University of Catalonia (UPC), Av. Eduard Maristany, 10–14, 08019 Barcelona, Spain
| | - Javier Gil
- Bioengineering Institute of Technology, Facultat de Medicina y Ciencias de la Salud, Universitat Internacional de Catalunya, 080195 Barcelona, Spain; (M.F.-F.); (R.P.)
- Correspondence:
| |
Collapse
|
2
|
Abstract
BACKGROUND Recent studies have attributed adverse local tissue reactions (ALTRs) in patients with total hip arthroplasties (THAs) to tribocorrosion debris generated by modular femoral stems. The presentations of ALTR are diverse, as are the causes of it, and the biological responses can be important reasons for failure after THA. QUESTION/PURPOSES (1) What clinical problems have been reported in patients with modular stems since 1988? (2) What THA design features are associated with tribocorrosion in taper junctions? (3) What are the microscopic and tribological characteristics of the debris produced at the taper junctions? (4) What are the cellular and immunological traits of the biological response to taper tribocorrosion debris? METHODS We conducted a systematic review using MEDLINE and EMBASE-cited articles to summarize failure modes associated with modular femoral stems. One hundred sixty-two of 1043 articles reported on the clinical performances or failure modes attributed to modular femoral stems. There were 10 laboratory studies, 26 case reports, 13 Level IV, 94 Level III, 18 Level II, and one Level I of Evidence papers. To address the remaining questions, we did a second review of 524 articles. One hundred twenty-seven articles met the eligibility criteria, including 81 articles on design features related to tribocorrosion, 15 articles on corrosion debris characteristics, and 31 articles on the biological response to tribocorrosion debris. RESULTS Sixty-eight of 162 studies reported failure attributed to modular femoral stems for one of these four modularity-related failure modes: tribocorrosion-associated ALTR, dissociation of a taper junction, stem fracture, and mismatch of a femoral head taper attached to a stem with a different trunnion size. The remaining 94 studies found no clinical consequences related to the presence of a taper junction. THA component features associated with tribocorrosion included trunnion geometry and large-diameter femoral heads. Solid tribocorrosion debris is primarily chromium-orthophosphate material of variable size and may be more biologically reactive than wear debris. CONCLUSIONS There has been an increase in publications describing ALTR around modular hip prostheses in the last 3 years. Implant design changes, including larger femoral heads and smaller trunnions, have been implicated, but there may also be more recognition of the problem by the orthopaedic community. Analyzing retrieved implants to understand the history of taper-related problems, designing clinically relevant in vitro corrosion tests to test modular junctions, and identifying biomarkers to recognize patients at risk of ALTR should be the focus of ongoing research to help surgeons avoid and detect tribocorrosion-related problems in joint replacements.
Collapse
|
3
|
Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. BIOMED RESEARCH INTERNATIONAL 2013; 2013:157247. [PMID: 23844356 PMCID: PMC3697280 DOI: 10.1155/2013/157247] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2013] [Accepted: 06/03/2013] [Indexed: 12/17/2022]
Abstract
Ceramic bearing surfaces are increasingly used for total hip replacement, notwithstanding that concern is still related to ceramic brittleness and its possible mechanical failure. The aim of this systematic review is to answer three questions: (1) Are there risk factors for ceramic component fracture following total hip replacement? (2) Is it possible to perform an early diagnosis of ceramic component failure before catastrophic fracture occurs? (3) Is it possible to draw guidelines for revision surgery after ceramic components failure? A PubMed and Google Scholar search was performed and reference citations from publications identified in the literature search were reviewed. The use of 28 mm short-neck femoral head carries an increased risk of fracture. Acetabular component malposition might increase the risk of ceramic liner fractures. Synovial fluid microanalysis and CT scan are promising in early diagnosis of ceramic head and liner failure. Early revision is suggested in case of component failure; no consensus exists about the better coupling for revision surgery. Ceramic brittleness remains a major concern. Due to the increased number of ceramic on ceramic implants, more revision surgeries and reports on ceramic components failure are expected in the future. An algorithm of diagnosis and treatment for ceramic hip failure is proposed.
Collapse
|
4
|
Abstract
The aim of this study was to detect risk factors for ceramic liner fractures. 26 cementless ceramic on ceramic (COC) total hip arthroplasties (THA) revised because of ceramic liner fracture in 24 patients were compared with 49 well-functioning COC THA performed in 49 patients. Demographic parameters, type of ceramic of the liner, size and neck length of the femoral head, cup abduction angle, cup anteversion, femoral off-set, height of the centre of rotation and the incidence of noisy hips during follow-up examination were compared. A greater number of cups placed outside the optimal range of cup anteversion was found in the fracture group (p = 0.03). An audible noise was detected in 21 cases (80.7%) in the fracture group and in 3 cases (6.1%) in the non-fracture group (p = 0.001). A cup anteversion angle out of the optimal range of 15˚+/-10˚ was found to be a risk factor for ceramic liner fracture and the presence of a noisy hip frequently anticipated the failure. In our opinion neck-to-cup impingement with head subluxation and edge loading on the liner rim could have an important role in the onset of noise and subsequent liner failure, and cup malposition contributes to this mechanism of failure.
Collapse
|
5
|
Catelas I, Wimmer MA. New insights into wear and biological effects of metal-on-metal bearings. J Bone Joint Surg Am 2011; 93 Suppl 2:76-83. [PMID: 21543694 PMCID: PMC3086265 DOI: 10.2106/jbjs.j.01877] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Despite the renewed interest in metal-on-metal implants in the past two decades, the underlying wear mechanisms and biological effects are still not fully understood. METHODS This paper first reviews the tribology of metal-on-metal bearings, bringing new insights into the interaction of wear and corrosion, and putting the characteristics and the potential origin of wear particles in perspective with the proposed wear mechanisms. It then summarizes the current knowledge on the biological effects of particles and metal ions in relation to these wear mechanisms. RESULTS Tribochemical reactions play an important role in the wear of metal-on-metal joints. The generated tribomaterial, which progressively forms by mechanical mixing of the uppermost nanocrystalline zone of the metal surface with proteins from the synovial fluid, governs the wear rate and influences the corrosive behavior of the bearing. Nanometer-sized wear particles may initially originate from the passivation layer covering the implant surface and then detach from this tribolayer. The inflammatory response observed surrounding metal-on-metal implants appears to be lower than that around metal-on-polyethylene implants. However, metallic byproducts, which can complex with proteins, may lead to a T lymphocyte-mediated hypersensitivity response. CONCLUSIONS The tribolayer appears to have beneficial effects on the wear rate. Much information has been gained on wear particle characteristics, but the exact mechanisms of particle detachment remain to be further elucidated. Excessive wear along with a hypersensitivity response may be at the origin of the early adverse tissue reactions that have been recently reported in some patients with metal-on-metal implants.
Collapse
Affiliation(s)
- Isabelle Catelas
- Department of Mechanical Engineering, University of Ottawa, 161 Louis Pasteur, Ottawa, ON K1N 6N5, Canada. E-mail address:
| | - Markus A. Wimmer
- Department of Orthopaedic Surgery, Rush University Medical Center, 1653 West Congress Parkway, Chicago, IL, 60612. E-mail address:
| |
Collapse
|
6
|
Polyethylene and metal wear particles: characteristics and biological effects. Semin Immunopathol 2011; 33:257-71. [PMID: 21267569 DOI: 10.1007/s00281-011-0242-3] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2010] [Accepted: 01/01/2011] [Indexed: 12/12/2022]
Abstract
This paper first presents a brief overview about the mechanism of wear particle formation as well as wear particle characteristics in metal-on-polyethylene and metal-on-metal artificial hip joints. The biological effects of such particles are then described, focusing on the inflammatory response induced by each type of particles as well as on how metal wear products may be the source of a T lymphocyte-mediated specific immune response, early adverse tissue responses, and genotoxicity. Finally, some of the current in vivo models used for the analysis of tissue response to various wear particles are presented.
Collapse
|
7
|
Mirza SB, Dunlop DG, Panesar SS, Naqvi SG, Gangoo S, Salih S. Basic science considerations in primary total hip replacement arthroplasty. Open Orthop J 2010; 4:169-80. [PMID: 20582240 PMCID: PMC2892068 DOI: 10.2174/1874325001004010169] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2009] [Revised: 11/10/2009] [Accepted: 03/05/2010] [Indexed: 01/27/2023] Open
Abstract
Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement.
Collapse
Affiliation(s)
- Saqeb B Mirza
- Trauma and Orthopaedics, Southampton University Hospitals NHS Trust, UK
| | | | | | | | | | | |
Collapse
|
8
|
Amanatullah DF, Cheung Y, Di Cesare PE. Hip resurfacing arthroplasty: a review of the evidence for surgical technique, outcome, and complications. Orthop Clin North Am 2010; 41:263-72. [PMID: 20399365 DOI: 10.1016/j.ocl.2010.01.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Hip resurfacing arthroplasty has reemerged as a valid reconstruction option for the osteoarthritic hip. Patient selection is critical for excellent surgical outcomes, especially when compared with total hip arthroplasty. However, concerns regarding surgical technique and postsurgical complications persist. The authors review the evidence for surgical technique, outcomes, and complications related to modern metal-on-metal hip resurfacing arthroplasty.
Collapse
Affiliation(s)
- Derek F Amanatullah
- Department of Orthopaedic Surgery, University of California Davis Medical Center, 4860 Y Street, Suite 3800, Sacramento, CA 95817, USA
| | | | | |
Collapse
|
9
|
Whittingham-Jones PM, Dunstan E, Altaf H, Cannon SR, Revell PA, Briggs TWR. Immune responses in patients with metal-on-metal hip articulations: a long-term follow-up. J Arthroplasty 2008; 23:1212-8. [PMID: 18534468 DOI: 10.1016/j.arth.2007.10.015] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2007] [Revised: 09/27/2007] [Accepted: 10/14/2007] [Indexed: 02/01/2023] Open
Abstract
Metal-on-metal (MoM) hip bearings are being inserted into ever-younger patients. The effects on the immune system of chronic exposure are unknown. We investigated the immune response of patients with MoM hip bearings. In patients with MoM implants, the expression of antigen-presenting cell (APC) surface molecules (CD86 and HLA-DR) was seen to be significantly higher (P < .05) than control group. High levels of APC surface molecules suggest an activated state and attempts to propagate an immune response. However, in the same group, the expression of T-cell markers (CD3 and CD28) was low, indicating a small T-cell population. This suggests, despite the activation of APCs, that T cells down-regulate immune responses in MoM articulations. Conversely, in metal-on-polyethylene articulations, expression of T-cell molecules was elevated and expression of APC molecules lowered.
Collapse
|
10
|
Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AVF. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. ACTA ACUST UNITED AC 2008; 90:1143-51. [PMID: 18757952 DOI: 10.1302/0301-620x.90b9.20785] [Citation(s) in RCA: 270] [Impact Index Per Article: 16.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Increased concentrations of metal ions after metal-on-metal resurfacing arthroplasty of the hip remain a concern. Although there has been no proven link to long-term health problems or early prosthetic failure, variables associated with high metal ion concentrations should be identified and, if possible, corrected. Our study provides data on metal ion levels from a series of 76 consecutive patients (76 hips) after resurfacing arthroplasty with the Articular Surface Replacement. Chromium and cobalt ion concentrations in the whole blood of patients with smaller (<or= 51 mm) femoral components were significantly higher than in those with the larger (>or= 53 mm) components (p < 0.01). Ion concentrations in the former group were significantly related to the inclination (p = 0.01) and anteversion (p = 0.01) of the acetabular component. The same relationships were not significant in the patients with larger femoral components (p = 0.61 and p = 0.49, respectively). Accurate positioning of the acetabular component intra-operatively is essential in order to reduce the concentration of metal ions in the blood after hip resurfacing arthroplasty with the Articular Surface Replacement implant.
Collapse
Affiliation(s)
- D J Langton
- Joint Replacement Unit, University Hospital of North Tees, Hardwick, Stockton-on-Tees TS19 8PE, UK.
| | | | | | | | | |
Collapse
|
11
|
Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing. J Arthroplasty 2008; 23:1080-5. [PMID: 18534479 DOI: 10.1016/j.arth.2007.09.024] [Citation(s) in RCA: 105] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2007] [Accepted: 09/28/2007] [Indexed: 02/01/2023] Open
Abstract
We describe 4 patients pooled from our patient populations who presented with groin pain at different periods postoperatively after implantation of a metal-on-metal hip resurfacing. Each patient underwent exploratory surgery after radiographic imaging, hematologic testing, and microbiological assessment of joint aspirations failed to explain their symptoms. Samples of periprosthetic tissues revealed extensive amounts of lymphocytic infiltrates that were suggestive of an immunologic reaction. The patients obtained complete resolution of symptoms subsequent to revision surgery. The incidence of implant failures resulting from metal sensitivity is unknown owing to the difficulty in making a confirmed diagnosis. The possibility that this is the source of groin pain should be considered when other reasons for symptoms of pain and/or joint effusion in hips with metal-on-metal resurfacing arthroplasties have been discounted.
Collapse
|
12
|
Abstract
The main advantage of hip resurfacing is bone conservation for patients likely to outlive a primary conventional hip replacement. Previous attempts at hip resurfacing failed predominantly because of the consequences of a high amount of wear of thin polyethylene acetabular components and poor femoral component fixation. With correct patient selection, surgeon education, and operative technique, survivorship at five years is comparable with that of traditional hip replacements. Hip resurfacing has its own unique set of complications, including a fractured neck of the femur. It is necessary to understand the risk factors prior to performing the procedure.
Collapse
Affiliation(s)
- Andrew Shimmin
- Melbourne Orthopaedic Group, 33 The Avenue, Windsor, Victoria 3181, Australia.
| | | | | |
Collapse
|
13
|
Lazennec JY, Boyer P, Poupon J, Rousseau MA, Laude F, El Balkhi S, Catonne Y, Saillant G. Second generation of metal-on-metal cemented total hip replacements: 12 years of clinical and biological follow-up. ACTA ACUST UNITED AC 2008. [DOI: 10.1007/s11610-007-0058-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
14
|
Pearle AD, Crow MK, Rakshit DS, Wohlgemuth J, Nestor BJ. Distinct inflammatory gene pathways induced by particles. Clin Orthop Relat Res 2007; 458:194-201. [PMID: 17224841 DOI: 10.1097/blo.0b013e3180320ae8] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The biologic response to particulate load after arthroplasty has not been fully characterized but is believed mediated by proinflammatory cytokines released from mononuclear cells in the periprosthetic region. To investigate the contribution of lymphocytes to expression of proinflammatory genes induced by metal particles, we compared gene expression of mononuclear cells in response to metal and polymethylmethacrylate particles using cDNA microarray profiling. Peripheral blood mononuclear cells and monocytes were stimulated with polymethylmethacrylate and titanium particles of clinically relevant sizes. Polymethylmethacrylate elicited a six- to 12-fold increase in gene expression of tumor necrosis factor alpha, interleukin 1alpha, interleukin 1beta, interleukin 6, and interleukin 8 in purified monocytes and unfractionated peripheral blood mononuclear cells. Although the effect of titanium on stimulation of purified monocytes was modest, stimulation of lymphocyte-containing peripheral blood mononuclear cells by titanium particles resulted in monocyte-derived proinflammatory cytokine expression. In contrast to polymethylmethacrylate, titanium particles stimulated increased expression of T lymphocyte-derived cytokines, including interleukin 2, interferon gamma, interleukin 9, and interleukin 22, in peripheral blood mononuclear cell cultures. The induction of T cell activation by titanium particles suggests lymphocytes may contribute to the inflammation that mediates osteolysis in patients with metallic particulate debris after total joint replacement.
Collapse
Affiliation(s)
- Andrew D Pearle
- Shoulder and Sports Medicine Service, Hospital for Special Surgery, New York, NY 10021, USA.
| | | | | | | | | |
Collapse
|
15
|
Witzleb WC, Hanisch U, Kolar N, Krummenauer F, Guenther KP. Neo-capsule tissue reactions in metal-on-metal hip arthroplasty. Acta Orthop 2007; 78:211-20. [PMID: 17464609 DOI: 10.1080/17453670710013708] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
BACKGROUND Modern-generation metal-on-metal articulations have a high wear resistance and may therefore be able to improve the long-term performance of artificial joints. However, the biological effects are still under debate. This study was undertaken to review the histopathological changes in neo-capsule tissues of different metal-on-metal hip arthroplasties. METHODS Neo-capsule tissue samples from 46 hips with modern second-generation metal-on-metal articulations (39 hip resurfacings and 7 non-cemented total hip replacements) with a variety of failure mechanisms were examined histopathologically and immunohistochemically. RESULTS A distinct lymphocytic infiltration was found in all cases with in situ times of more than 7 months, consisting of CD20-positive B-lymphocytes and CD3-positive T-lymphocytes and sometimes thinly distributed CD138-positive plasma cells without dominant T-cell or plasma cell infiltrates. INTERPRETATION This distinct lymphocytic infiltration has not been reported in tissue analyses of metal- or ceramic-on-polyethylene hip replacements, and may therefore be considered to be a characteristic histological pattern of tissue reactions on metal particles and/or ions around metal-on-metal bearings.
Collapse
Affiliation(s)
- Wolf-Christoph Witzleb
- Department of Orthopaedic Surgery, University Hospital Carl Gustav Carus, Dresden, Germany.
| | | | | | | | | |
Collapse
|
16
|
Campbell P, Beaulé PE, Ebramzadeh E, Le Duff MJ, LeDuff M, De Smet K, Lu Z, Amstutz HC. The John Charnley Award: a study of implant failure in metal-on-metal surface arthroplasties. Clin Orthop Relat Res 2006; 453:35-46. [PMID: 16906115 DOI: 10.1097/01.blo.0000238777.34939.82] [Citation(s) in RCA: 193] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
- Pat Campbell
- Joint Replacement Institute, Orthopaedic Hospital, 2400 S. Flower Street, Los Angeles, CA 90007, USA.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Jell G, Kerjaschki D, Revell P, Al-Saffar N. Lymphangiogenesis in the bone-implant interface of orthopedic implants: importance and consequence. J Biomed Mater Res A 2006; 77:119-27. [PMID: 16392126 DOI: 10.1002/jbm.a.30548] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The lymphatic system plays an essential physiological role in homeostasis, interstitial fluid composition, and immunity while impaired lymphatic function has been implicated in a number of pathological conditions, including arthritis and delayed wound healing. This study investigated lymphatic capillary growth and lymphangiogenesis pathways in the bone-implant interface from patients with aseptically loosened prosthetic joints. The newly developed lymphatic specific marker, podoplanin, has enabled the first demonstration of lymphatic capillaries in peri-prosthetic tissues (60% of cases contained podoplanin positive vessels). The pro-lymphangiogenic factor (VEGF-C) and its receptor VEGFR-3 showed high level of expression in these tissues, (often in areas of high levels of wear debris). However despite the upregulation of the lymphangiogenesis pathway by a VEGF-C/VEGFR-3-mediated mechanism, there were relatively few podoplanin positive lymphatic vessels in the bone-implant interface (3.4% of total vessels). This may have important pathological consequences in terms of perpetuating inflammation and edema by inhibiting the removal of macromolecules, cells, and interstitial fluid. The identification of lymphatic vessels with internalized polyethylene wear particles provides evidence of this route of wear debris transportation to distal sites. This paper highlights the importance of lymphatic vessels in the maintenance of local and distal inflammatory responses to prosthetic wear particles.
Collapse
Affiliation(s)
- Gavin Jell
- Department of Materials, Imperial College London, South Kensington Campus, Exhibition Road, London, United Kingdom.
| | | | | | | |
Collapse
|
18
|
Cobb AG, Schmalzreid TP. The clinical significance of metal ion release from cobalt-chromium metal-on-metal hip joint arthroplasty. Proc Inst Mech Eng H 2006; 220:385-98. [PMID: 16669404 DOI: 10.1243/09544119jeim78] [Citation(s) in RCA: 83] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Metal-on-metal (MOM) bearings offer extremely low wear and the avoidance of polyethylene but generate metallic wear particles. Although their total volume is dramatically smaller than polyethylene debris, these particles are in the nanometre size range and are many times more numerous. Metallic particles are ingested by macrophages or may be disseminated via lymphatics to the reticuloendothelial system. They corrode, and metal ions are present in the circulation and concentrated in erythrocytes. Excretion of metal ions via the kidneys seems to balance their generation in patients with MOM implants. However, highly sensitive detection methods can be used to show that levels of circulating cobalt and chromium ions are several times the normal level. These concentrations are well within the limits identified as dangerous to health in workers exposed to industrial chemicals, and also considerably lower than the levels found to cause cell toxicity in vitro. The local concentrations of particles and metal ions in the synovial tissue may occasionally exceed these limits and cause tissue necrosis. Clinical experience of lysis is rare in association with MOM bearings, as are hypersensitivity reactions and MOM bearings have had an excellent record over four decades and have a favourable benefit to risk ratio. Further reduction in risk will be achieved by improvement of materials, engineering, and accuracy of insertion.
Collapse
Affiliation(s)
- A G Cobb
- Epsom General Hospital, Epsom, Surrey, United Kingdom.
| | | |
Collapse
|
19
|
Clarke IC, Donaldson T, Bowsher JG, Nasser S, Takahashi T. Current concepts of metal-on-metal hip resurfacing. Orthop Clin North Am 2005; 36:143-62, viii. [PMID: 15833452 DOI: 10.1016/j.ocl.2005.02.007] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The second-generation, metal-on-metal (MOM) bearing for total hip replacements was launched in the 1980s, and resurfacing followed in the mid-1990s. Remaining challenges include long-term bone remodeling of the femoral resurfacing and consideration of adverse MOM wear conditions. Precise understanding of manufacturing variables such as alloy types, bearing diameters, design tolerances, and surface finish is imperative in obtaining clinical consistency and safety in the patient. This review examines femoral fixation, bone remodeling, and wear studies of MOM implants and provides a brief overview of the latest outcome and retrieval data and how these data integrate with the in vitro wear studies.
Collapse
Affiliation(s)
- Ian C Clarke
- Orthopedic Research Center, 11406 Loma Linda Drive #606, Loma Linda University Medical Center, Loma Linda, CA 92354, USA.
| | | | | | | | | |
Collapse
|
20
|
DAVIES AP, WILLERT HG, CAMPBELL PA, LEARMONTH ID, CASE CP. AN UNUSUAL LYMPHOCYTIC PERIVASCULAR INFILTRATION IN TISSUES AROUND CONTEMPORARY METAL-ON-METAL JOINT REPLACEMENTS. J Bone Joint Surg Am 2005. [DOI: 10.2106/00004623-200501000-00005] [Citation(s) in RCA: 69] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|
21
|
Abstract
Metal-on-metal bearings have wear rates that are 20 to 100 times lower than metal-on-conventional polyethylene. The amount of wear generally is the same order of magnitude for the head and the cup. There is an initial run-in period of higher wear followed by lower, steady-state wear. Wear rate is a function of the interplay of material(s), macrogeometry, microgeometry, and the resultant type and amount of lubrication. The wear resistance and clinical performance of a metal-on-metal bearing are more sensitive to macrogeometry and lubrication than a metal-on-polyethylene bearing. Metal wear particles are nanometers in linear dimension. They are much smaller and more numerous than the submicron polyethylene wear particles, but the volume of periprosthetic inflammatory tissue is less. Osteolysis seems to be relatively rare. Little is known about the systemic distribution of metal particles and ions. The significance of systemic distribution also is not known. The levels of serum and urine Co and Cr ions are elevated in patients with metal-on-metal bearings, but the long-term, steady-state levels are not much higher than those from corrosion of modular femoral components. Because of the elevated levels of Co and Cr ions, there is a greater risk of delayed type hypersensitivity. There also is concern about the potential for malignant degeneration secondary to prolonged exposure to these elements. The available data are insufficient to address this concern. Rigorous long-term studies are needed. It will take decades of close clinical observation to determine if the benefits of metal-on-metal bearings outweigh the associated risks.
Collapse
Affiliation(s)
- Mauricio Silva
- Joint Replacement Institute at Orthopaedic Hospital, Los Angeles, CA 90007, USA
| | | | | |
Collapse
|
22
|
Davies AP, Willert HG, Campbell PA, Learmonth ID, Case CP. An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements. J Bone Joint Surg Am 2005; 87:18-27. [PMID: 15634811 DOI: 10.2106/jbjs.c.00949] [Citation(s) in RCA: 299] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Metal-on-metal bearing surfaces have been reintroduced for use during total hip replacement. To assess tissue reactions to various types of articulations, we studied the histological appearance of periprosthetic tissues retrieved from around metal-on-metal and metal-on-polyethylene total hip replacements and compared these findings with the appearance of control tissues retrieved at the time of primary arthroplasty. METHODS Periprosthetic tissues were obtained at the time of revision of twenty-five cobalt chromium-on-cobalt chromium, nine cobalt chromium-on-polyethylene, and ten titanium-on-polyethylene total hip arthroplasties. Control tissues were obtained from nine osteoarthritic hips at the time of primary total hip arthroplasty. Each tissue sample was processed for routine histological analysis, and sections were stained with hematoxylin and eosin. Quantitative stereological analysis was performed with use of light microscopy. RESULTS Tissue samples obtained from hips with metal-on-metal implants displayed a pattern of well-demarcated tissue layers. A prominent feature, seen in seventeen of twenty-five tissue samples, was a pattern of perivascular infiltration of lymphocytes. In ten of the tissue samples obtained from hips with metal-on-metal prostheses, there was also an accumulation of plasma cells in association with macrophages that contained metallic wear-debris particles. The surfaces of tissues obtained from hips with metal-on-metal prostheses were more ulcerated than those obtained from hips with other types of implants, particularly in the region immediately superficial to areas of perivascular lymphocytic infiltration. The lymphocytic infiltration was more pronounced in samples obtained at the time of revision because of aseptic failure than in samples retrieved at the time of autopsy or during arthrotomy for reasons other than aseptic failure. Total-joint-replacement and surface-replacement designs of metal-on-metal prostheses were associated with similar results. Tissue samples obtained from hips with metal-on-polyethylene implants showed far less surface ulceration, much less distinction between tissue layers, no pattern of lymphocytic infiltration, and no plasma cells. The inflammation was predominantly histiocytic. Tissues retrieved from hips undergoing primary joint replacement showed dense scar tissue and minimal inflammation. CONCLUSIONS AND CLINICAL RELEVANCE The pattern and type of inflammation seen in periprosthetic tissues obtained from hips with metal-on-metal and metal-on-polyethylene implants are very different. At the present time, we do not know the prevalence or clinical implications of these histologic findings, but we suggest that they may represent a novel mode of failure for some metal-on-metal joint replacements.
Collapse
Affiliation(s)
- A P Davies
- Bristol Implant Research Centre, Avon Orthopaedic Centre, Southmead Hospital, Bristol, BS10 5NB, United Kingdom.
| | | | | | | | | |
Collapse
|
23
|
Amstutz HC, Beaulé PE, Dorey FJ, Le Duff MJ, Campbell PA, Gruen TA. Metal-on-Metal Hybrid Surface Arthroplasty: Two to Six-Year Follow-up Study. J Bone Joint Surg Am 2004. [DOI: 10.2106/00004623-200401000-00006] [Citation(s) in RCA: 504] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
|
24
|
HEISEL CHRISTIAN, SILVA MAURICIO, SCHMALZRIED THOMASP. BEARING SURFACE OPTIONS FOR TOTAL HIP REPLACEMENT IN YOUNG PATIENTS. J Bone Joint Surg Am 2003. [DOI: 10.2106/00004623-200307000-00026] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
|