1
|
McCarroll TR, Kuhns BD, Domb BG. Surgical Management of Hip Pain in Active Patients With Early Osteoarthritis: Navigating the Choice Between Hip Preservation and Arthroplasty. J Am Acad Orthop Surg 2025; 33:336-345. [PMID: 39847713 DOI: 10.5435/jaaos-d-24-00242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 11/25/2024] [Indexed: 01/25/2025] Open
Abstract
Hip pain in active patients with early osteoarthritis can be quite debilitating, affecting mobility, quality of life, and overall well-being. Management of this patient population is challenging because arthroplasty implants inevitably have limited life expectancy while chondral damage can mitigate the benefits of arthroscopic or open hip preservation. A multifaceted, patient-specific approach to clinical decision making is crucial in this patient population, given their higher activity level and expectations compared with older cohorts. Several advances have been made to better stratify patients into the spectrum of management, which includes nonsurgical measures; injections, including orthobiologics; arthroscopic hip preservation; open hip preservation; hip resurfacing; and total hip arthroplasty.
Collapse
Affiliation(s)
- Tyler R McCarroll
- From the American Hip Institute Research Foundation (McCarroll and KuhnsDomb), Chicago, IL, and the American Hip Institute (KuhnsDomb), Chicago, IL
| | | | | |
Collapse
|
2
|
Zuke WA, Hannon CP, Salih R, Kromka J, Granger C, Clohisy JC, Barrack RL. Long-Term Results of the Birmingham Hip Resurfacing Implant in the United States: An Updated Analysis of a Single Institution's Experience. J Bone Joint Surg Am 2025; 107:e19. [PMID: 39908356 PMCID: PMC11905902 DOI: 10.2106/jbjs.24.00926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2025]
Abstract
BACKGROUND We previously reported the 5-year results of the Birmingham Hip Resurfacing (BHR) implant. This study evaluates BHR survivorship as well as radiographic and clinical outcomes at long-term follow-up. METHODS A total of 224 patients with contemporary indications, including 179 patients from the original study, were included in this analysis. Survivorship was calculated. Metal ion levels and radiographs were updated. Patient-reported outcomes (PROs) were compared with those for matched patients who had undergone total hip arthroplasty (THA). The mean follow-up was 14 years. RESULTS Survivorship free from any revision and from aseptic revision was 96.0% and 97.4% at 15 years, respectively. Two patients had undergone revision since the original study. The median serum cobalt and chromium levels were 1.4 and 1.5 ppb, respectively. The PROs were similar to those for the THA cohort. Equal proportions of patients remained active; however, the BHR group trended toward more remaining highly active (p = 0.12). CONCLUSIONS Although activity was similar to THA at long-term follow-up, the BHR implant remains an excellent option for the treatment of osteoarthritis in younger male patients. LEVEL OF EVIDENCE Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- William A. Zuke
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | - Charles P. Hannon
- Department of Orthopaedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rondek Salih
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | - Joseph Kromka
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | - Caroline Granger
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | - John C. Clohisy
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| | - Robert L. Barrack
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
| |
Collapse
|
3
|
Kocaoğlu H, Crawford R, Parvizi J, Powell JN, Smailys A, Yakub S. Is There a Role for Resurfacing Hip Arthroplasty for Patients Who Have Arthritis of the Hip? J Arthroplasty 2025; 40:S125-S127. [PMID: 39454842 DOI: 10.1016/j.arth.2024.10.092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2024] [Revised: 10/17/2024] [Accepted: 10/18/2024] [Indexed: 10/28/2024] Open
Affiliation(s)
- Hakan Kocaoğlu
- Faculty of Medicine, Department of Orthopaedics and Traumatology, Ankara University, Ankara, Turkey
| | - Ross Crawford
- Orthopaedic Research Unit, Queensland University of Technology, Brisbane, Queensland, Australia; The Prince Charles Hospital, Chermside, Queensland, Australia
| | - Javad Parvizi
- International Joint Centre (IJC), Acibadem Maslak Hospital, Istanbul, Turkey; Department of Orthopedics and Traumatology, Acibadem Mehmet Ali Aydınlar University, Istanbul, Turkey
| | - James N Powell
- Division of Orthopaedic Surgery, Department of Surgery, University of Calgary Cumming School of Medicine, Calgary, Canada
| | - Alfredas Smailys
- Department of Orthopedics and Traumatology, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Saheed Yakub
- Orthopaedic Unit, Department of Surgery, UNIOSUN Teaching Hospital, Osogbo, Nigeria
| |
Collapse
|
4
|
Fong S, Shah AK, Hecht CJ, Kamath AF. What is the long-term survivorship, complication profile, and patient reported outcomes after Birmingham hip resurfacing? J Orthop 2024; 55:134-148. [PMID: 38706587 PMCID: PMC11063114 DOI: 10.1016/j.jor.2024.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2024] [Accepted: 04/14/2024] [Indexed: 05/07/2024] Open
Abstract
Introduction When indicated, Birmingham Hip Resurfacing (BHR) presents a viable alternative to total hip arthroplasty (THA), but there remain questions about the long-term outcomes of BHR. Therefore, we asked: 1) what are the long-term patient-reported outcomes and 2) survivorship rates following BHR; 3) what are the causes for revision surgery after BHR? and 4) how have these outcomes compared to THA at long-term follow-up. Methods A query of PubMed, MEDLINE, Scopus, and Cochrane in September 2023 was performed. Articles were included if they reported BHR survivorship rates at ≥10 years. Survivorship was defined as an all-cause revision of any BHR component. This review encompasses 26 articles, totaling 13,103 hips. Mean follow-up ranged from 6.0 to 20.9 years, but each study had at least a subgroup analysis for ≥10-year follow-up. Results Five studies compared preoperative and postoperative PROs for BHR, with four reporting improvement in at least one PRO after 10-year follow-up. Overall, survivorship rates ranged from 83% to 100% across diverse long-term timeframes, with 25 of 26 studies reporting 10-year survivorship rates greater than 87%. The primary reasons for revisions were implant loosening (22%), adverse reactions to metal debris (21.2%), and fractures of any kind (17.2%). In the six studies that compared BHR to THA, long-term survivorship was similar while BHR exhibited slightly superior activity levels. Conclusion The findings from this study suggested favorable long-term survivorship and postoperative outcomes of BHR. In studies comparing long-term BHR and THA, survivorship was comparable, with BHR potentially providing enhanced postoperative activity levels.
Collapse
Affiliation(s)
- Scott Fong
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Aakash K. Shah
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Christian J. Hecht
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| | - Atul F. Kamath
- Department of Orthopaedic Surgery, Cleveland Clinic Foundation, Cleveland, OH, 44195, USA
| |
Collapse
|
5
|
Pasqualini I, Huffman N, Emara AK, Klika AK, McLaughlin JP, Mesko N, Brooks PJ, Piuzzi NS. Establishing minimal clinically important differences and patient acceptable symptom state thresholds following birmingham hip resurfacing. Arch Orthop Trauma Surg 2024; 144:3729-3737. [PMID: 38981870 PMCID: PMC11417060 DOI: 10.1007/s00402-024-05443-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Accepted: 06/27/2024] [Indexed: 07/11/2024]
Abstract
INTRODUCTION Birmingham Hip Resurfacing (BHR) has emerged as a compelling and innovative alternative to total hip arthroplasty (THA), especially among young, active patients. However, the Minimal Clinically Important Difference (MCID) and the Patient Acceptable Symptom State (PASS) thresholds have not yet been determined for patients undergoing BHR. Therefore, the current study aimed to (1) determine the MCID and PASS thresholds for both the Hip disability and Osteoarthritis Outcome Score (HOOS)-Pain and HOOS physical function shortform (PS), for patients who underwent BHR; and (2) identify factors influencing the achievement of MCID and PASS for HOOS-Pain and HOOS-PS. METHODS Prospectively collected data from patients undergoing BHR was analyzed. Patients with osteoarthritis and completed preoperative and 1-year postoperative PROMs were included. Distribution-based and anchored-based approaches were used to estimate MCID and PASS, respectively. The optimal cut-off point for PASS thresholds was calculated using the Youden index. RESULTS MCID for HOOS-Pain and PS were calculated to be 9.2 and 9.3, respectively. The PASS threshold for HOOS-Pain and PS were ≥ 77.7 and ≥ 87.3, respectively. The current study identified several factors affecting postoperative achievement of thresholds. Baseline Mental Component Summary (MCS) scores were a predictor for achieving MCID for postoperative HOOS-Pain, achieving MCID for postoperative HOOS-PS, achieving PASS for postoperative HOOS-Pain, and achieving PASS for postoperative HOOS-PS. Furthermore, baseline HOOS-Pain was a significant predictor for achieving MCID for postoperative HOOS-PS, achieving PASS for postoperative HOOS-Pain, and achieving PASS for postoperative HOOS-PS. CONCLUSIONS MCID and PASS thresholds were established for HOOS-Pain and PS domains following BHR with most patients achieving these clinically meaningful benchmarks. Additionally, several factors affecting achievement of MCID and PASS were identified, including modifiable risk factors that may allow clinicians to implement optimization strategies and further improve outcomes.
Collapse
Affiliation(s)
- Ignacio Pasqualini
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Nickelas Huffman
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Ahmed K Emara
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Alison K Klika
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - John P McLaughlin
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Nathan Mesko
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Peter J Brooks
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA
| | - Nicolas S Piuzzi
- Department of Orthopaedic Surgery, Orthopedic and Rheumatology Institute, Cleveland Clinic, 9500 Euclid Ave, A41, Cleveland, OH, 44195, USA.
- Department of Biomedical Engineering, Cleveland Clinic Foundation, 9500 Euclid Ave, Cleveland, OH, USA.
| |
Collapse
|
6
|
Nandra RS, Elnahal WA, Mayne A, Brash L, McBryde CW, Treacy RBC. Birmingham Hip Resurfacing at 25 years. Bone Joint J 2024; 106-B:540-547. [PMID: 38821495 DOI: 10.1302/0301-620x.106b6.bjj-2023-1064.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/02/2024]
Abstract
Aims The Birmingham Hip Resurfacing (BHR) was introduced in 1997 to address the needs of young active patients using a historically proven large-diameter metal-on-metal (MoM) bearing. A single designer surgeon's consecutive series of 130 patients (144 hips) was previously reported at five and ten years, reporting three and ten failures, respectively. The aim of this study was to extend the follow-up of this original cohort at 25 years. Methods The study extends the reporting on the first consecutive 144 resurfacing procedures in 130 patients for all indications. All operations were undertaken between August 1997 and May 1998. The mean age at operation was 52.1 years (SD 9.93; 17 to 76), and included 37 female patients (28.5%). Failure was defined as revision of either component for any reason. Kaplan-Meier survival analysis was performed. Routine follow-up with serum metal ion levels, radiographs, and Oxford Hip Scores (OHSs) was undertaken. Results Overall implant survival was 83.50% (95% confidence interval (CI) 0.79 to 0.90) at 25 years, and the number at risk was 79. Survival in male patients at 25 years was 89.5% (95% CI 0.83 to 0.96) compared to 66.9% for female patients (95% CI 0.51 to 0.83). Ten additional failures occurred in the period of ten to 25 years. These involved an adverse reaction to metal debris in four patients, a periprosthetic femoral neck fracture affecting five patients, and aseptic loosening in one patient. The median chromium levels were 49.50 nmol/l (interquartile range (IQR) 34 to 70), and the median cobalt serum levels were 42 nmol/l (IQR 24.50 to 71.25). The median OHS at last follow-up was 35 (IQR 10 to 48). During the 25-year study period, 29 patients died. Patient survival at 25 years was 75.10% (95% CI 0.67 to 0.83). Conclusion This study demonstrates that MoM hip resurfacing using the BHR provides a durable alternative to total hip arthroplasty (THA), particularly in younger male patients with osteoarthritis wishing to maintain a high level of function. These results compare favourably to the best results for THAs.
Collapse
Affiliation(s)
- Rajpal S Nandra
- Lower Limb Reconstruction, Robert Jones Agnes Hunt Hospital, Gobowen, UK
| | - Walid A Elnahal
- The Royal Orthopaedic Hospital, Birmingham, UK
- Faculty of Medicine, Cairo University, Cairo, Egypt
| | | | | | - Callum W McBryde
- The Royal Orthopaedic Hospital, Birmingham, UK
- The Woodlands, Birmingham, UK
| | - Ronan B C Treacy
- The Royal Orthopaedic Hospital, Birmingham, UK
- The Woodlands, Birmingham, UK
| |
Collapse
|
7
|
Akçaalan S, Kengil MC, Çağlar C, Uğurlu M. Is there still an indication for the Birmingham Hip Resurfacing in femoral head osteonecrosis? INTERNATIONAL ORTHOPAEDICS 2024; 48:1157-1163. [PMID: 38165447 DOI: 10.1007/s00264-023-06070-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE Osteonecrosis of the femoral head (ONFH) is a progressive hip disease. Hip resurfacing arthroplasty (HRA) is a preferred surgical procedure among hip arthroplasty performed in young patients. The aim of this study is to show the long-term clinical and radiological results of HRA procedures performed for patients suffering from ONFH. METHODS Forty-five patients who underwent hip resurfacing with the diagnosis of femoral head osteonecrosis were included in the study. The Harris Hip Score (HHS) was used for clinical scoring of the patients. The blood chromium, cobalt, white blood cell (WBC) count, and CRP levels of patients were checked. Ultrasonography (USG) was performed for all patients at mid-term control checked for pseudo-tumours. For the radiological evaluation, acetabular inclination, stem shaft angle, prothesis-to-neck ratio, osteolysis zones, and heterotopic ossification were used. RESULTS The mean age of the patients was 46.6 ± 9.3 years, and the mean follow-up period was 11.83 ± 2.9 years. The mean HHS was 90.3 ± 12.8 for final follow-up. The mean WBC value was 8.2 109/L, mean CRP value was 6.3 mg/L, mean chromium value was 4.9 µg/L, and mean cobalt value was 1.8 µg/L. Inclination changing 0.2°(p = 0.788), stem shaft angle changing 0.7°(p = 0.424), and neck-to-prosthesis ratio changing 0.01°(p = 0.075). No pseudo-tumours were detected in any patients in USG examination. CONCLUSION HRA provides long-term implant survival and excellent clinical outcomes for end-stage ONFH patients with low complication rates.
Collapse
Affiliation(s)
- Serhat Akçaalan
- Orthopedics and Traumatology Department, Ankara City Hospital, Ankara, Turkey.
| | - Mehmet Can Kengil
- Orthopedics and Traumatology Department, Ankara City Hospital, Ankara, Turkey
| | - Ceyhun Çağlar
- Orthopedics and Traumatology Department, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| | - Mahmut Uğurlu
- Orthopedics and Traumatology Department, Ankara Yıldırım Beyazıt University, Ankara, Turkey
| |
Collapse
|
8
|
LaValva SM, LeBrun DG, Canoles HG, Ren R, Padgett DE, Su EP. Clinical outcomes and return to dance after total hip arthroplasty or hip resurfacing in professional dancers. Bone Joint J 2024; 106-B:17-23. [PMID: 38425296 DOI: 10.1302/0301-620x.106b3.bjj-2023-0854.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims Professional dancers represent a unique patient population in the setting of hip arthroplasty, given the high degree of hip strength and mobility required by their profession. We sought to determine the clinical outcomes and ability to return to professional dance after total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA). Methods Active professional dancers who underwent primary THA or HRA at a single institution with minimum one-year follow-up were included in the study. Primary outcomes included the rate of return to professional dance, three patient-reported outcome measures (PROMs) (modified Harris Hip Score (mHHS), Hip disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS-JR), and Lower Extremity Activity Scale (LEAS)), and postoperative complications. Results A total of 49 hips in 39 patients (mean age 56 years (SD 13); 80% female (n = 39)) were included. Mean follow-up was 4.9 years (SD 5.1). Of these 49 hips, 37 THAs and 12 HRAs were performed. In all, 96% of hips returned to professional dance activities postoperatively. With regard to PROMs, there were statistically significant improvements in mHHS, HOOS-JR, and LEAS from baseline to ≥ one year postoperatively. There were complications in 7/49 hips postoperatively (14%), five of which required revision surgery (10%). There were no revisions for instability after the index procedure. Two complications (5.4%) occurred in hips that underwent THA compared with five (42%) after HRA (p = 0.007), though the difference by procedure was not significantly different when including only contemporary implant designs (p = 0.334). Conclusion Active professional dancers experienced significant improvements in functional outcome scores after THA or HRA, with a 96% rate of return to professional dance. However, the revision rate at short- to mid-term follow-up highlights the challenges of performing hip arthroplasty in this demanding patient population. Further investigation is required to determine the results of THA versus HRA using contemporary implant designs in these patients.
Collapse
Affiliation(s)
- Scott M LaValva
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Drake G LeBrun
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Haley G Canoles
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Renee Ren
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Douglas E Padgett
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Edwin P Su
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
9
|
Uklejewski R, Winiecki M, Dąbrowski M, Rogala P. Towards the First Generation of Biomimetic Fixation for Resurfacing Arthroplasty Endoprostheses. Biomimetics (Basel) 2024; 9:99. [PMID: 38392145 PMCID: PMC10887084 DOI: 10.3390/biomimetics9020099] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/21/2024] [Accepted: 02/06/2024] [Indexed: 02/24/2024] Open
Abstract
This paper presents advances in designs of resurfacing arthroplasty endoprostheses that occurred through their historical generations. The critical characteristics of contemporary generation hip resurfacing arthroplasty endoprostheses are given and the failures resulting from the specific generation cemented and short stem fixation of the femoral component are reviewed. On the background of these failures, the critical need arises for an alternative approach to the fixation of components of resurfacing arthroplasty leading towards the first generation of biomimetic fixation for resurfacing arthroplasty endoprostheses. The state of the art of the completed bioengineering research on the first biomimetic fixation for resurfacing arthroplasty endoprostheses is presented. This new design type of completely cementless and stemless resurfacing arthroplasty endoprostheses of the hip joint (and other joints), where endoprosthesis components are embedded in the surrounding bone via the prototype biomimetic multi-spiked connecting scaffold (MSC-Scaffold), initiates the first at all generations of biomimetic endoprostheses of diarthrodial joints.
Collapse
Affiliation(s)
- Ryszard Uklejewski
- Department of Constructional Materials and Biomaterials, Faculty of Materials Engineering, Kazimierz Wielki University, Jan Karol Chodkiewicz Street 30, 85-064 Bydgoszcz, Poland
| | - Mariusz Winiecki
- Department of Constructional Materials and Biomaterials, Faculty of Materials Engineering, Kazimierz Wielki University, Jan Karol Chodkiewicz Street 30, 85-064 Bydgoszcz, Poland
| | - Mikołaj Dąbrowski
- Adult Spine Orthopaedics Department, Wiktor Dega Orthopaedic and Rehabilitation Clinical Hospital, Poznan University of Medical Sciences, 28 Czerwca 1956 Street 135/147, 61-545 Poznan, Poland
| | - Piotr Rogala
- Institute of Health Sciences, Hipolit Cegielski State College of Higher Education, Card. Stefan Wyszyński Street 38, 62-200 Gniezno, Poland
| |
Collapse
|
10
|
Zgouridou A, Kenanidis E, Potoupnis M, Tsiridis E. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1219-1251. [PMID: 37768398 PMCID: PMC10858160 DOI: 10.1007/s00590-023-03691-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 08/13/2023] [Indexed: 09/29/2023]
Abstract
PURPOSE Four joint arthroplasty registries (JARs) levels exist based on the recorded data type. Level I JARs are national registries that record primary data. Hospital or institutional JARs (Level II-IV) document further data (patient-reported outcomes, demographic, radiographic). A worldwide list of Level II-IV JARs must be created to effectively assess and categorize these data. METHODS Our study is a systematic scoping review that followed the PRISMA guidelines and included 648 studies. Based on their publications, the study aimed to map the existing Level II-IV JARs worldwide. The secondary aim was to record their lifetime, publications' number and frequency and recognise differences with national JARs. RESULTS One hundred five Level II-IV JARs were identified. Forty-eight hospital-based, 45 institutional, and 12 regional JARs. Fifty JARs were found in America, 39 in Europe, nine in Asia, six in Oceania and one in Africa. They have published 485 cohorts, 91 case-series, 49 case-control, nine cross-sectional studies, eight registry protocols and six randomized trials. Most cohort studies were retrospective. Twenty-three per cent of papers studied patient-reported outcomes, 21.45% surgical complications, 13.73% postoperative clinical and 5.25% radiographic outcomes, and 11.88% were survival analyses. Forty-four JARs have published only one paper. Level I JARs primarily publish implant revision risk annual reports, while Level IV JARs collect comprehensive data to conduct retrospective cohort studies. CONCLUSIONS This is the first study mapping all Level II-IV JARs worldwide. Most JARs are found in Europe and America, reporting on retrospective cohorts, but only a few report on studies systematically.
Collapse
Affiliation(s)
- Aikaterini Zgouridou
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eustathios Kenanidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece.
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
| | - Michael Potoupnis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eleftherios Tsiridis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| |
Collapse
|
11
|
Shah RV, Ly JA, Magnuson JA, Thompson M, Lorei MP. Hip resurfacing: case closed? A bibliometric analysis of the past 10 years. Arch Orthop Trauma Surg 2024; 144:909-916. [PMID: 37792058 DOI: 10.1007/s00402-023-05075-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Accepted: 09/17/2023] [Indexed: 10/05/2023]
Abstract
INTRODUCTION Hip resurfacing (HR) was introduced as a potential alternative to total hip arthroplasty (THA), indicated predominantly for younger, high demand patients. The modern metal-on-metal implant was popularized in the 1990s and early 2000s and promised greater wear resistance. However, its popularity waned due to increased rates of complications related to metal toxicity including pseudo-tumors as well as the recall of many resurfacing implants. The purpose of this study was to conduct a bibliometric analysis and investigate the current trends in hip resurfacing literature. METHODS Using the keywords "hip resurfacing," publications between 2012 and 2022 were identified on Web of Science Core Collection of Clarivate Analytics. Results were screened for relevance by three independent reviewers using title, abstract, and full text. The retrieved data were evaluated by the bibliometric method. Included articles were imported into CiteSpace 5.7.R1, 64-bit (Drexel University, Philadelphia, PA, USA), VOSviewer 1.6.15 (Leiden University, Leiden, the Netherlands), and the Online Analysis Platform of Literature Metrology to identify trends in publication. RESULTS Search terms yielded 1200 results and 724 were included in final analysis. A steady decrease of publications was noted over the past decade with less than 40 articles published in 2020 and 2021. The Journal of Hip Arthroplasty (92), Hip International (74), and Clinical Orthopaedics and Related Research (54) published the most articles. Authors from the United States and the United Kingdom published the most studies. High-frequency keywords in co-occurrence and co-cited cluster analysis were metal-on-metal, metal ions, wear, pseudo-tumor, and revision, demonstrating that long-term concerns have been the focus of most recent studies. CONCLUSION In conclusion, our bibliometric analysis allowed novel exploration and identification of the current research trends, contributions, and the distribution of publications exploring HR. The understanding of HR and the poor long-term outcomes of some resurfacing implants has improved significantly over the past decade, with the most recent focus on failure rates and long-term complications from metal debris. However, the breadth of literature has steadily declined in the past decade, and ultimately demonstrates the decline of scientific interest and focus on novel areas in hip resurfacing and a potential reached consensus.
Collapse
Affiliation(s)
- Ronit V Shah
- Department of Orthopaedic Surgery and Sports Medicine, Temple University Hospital, Philadelphia, PA, 19140, USA.
| | - Justin A Ly
- Department of Orthopaedic Surgery and Sports Medicine, Temple University Hospital, Philadelphia, PA, 19140, USA
| | | | - Megan Thompson
- Lewis Katz School of Medicine at, Temple University, Philadelphia, PA, 19140, USA
| | - Matthew P Lorei
- Department of Orthopaedic Surgery and Sports Medicine, Temple University Hospital, Philadelphia, PA, 19140, USA
| |
Collapse
|
12
|
Ramkumar PN, Shaikh HJF, Woo JJ, Haeberle HS, Pang M, Brooks PJ. Hip resurfacing arthroplasty as an alternative to total hip arthroplasty in patients aged under 40 years. Bone Jt Open 2023; 4:408-415. [PMID: 37257853 PMCID: PMC10232079 DOI: 10.1302/2633-1462.46.bjo-2023-0015.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/02/2023] Open
Abstract
Aims The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate. Methods This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database. Results A total of 217 hips (81%) were included for follow-up analysis at a mean of 3.8 years. Of the 23 females who underwent HRA, none were revised, and the median head size was 46 mm (compared to 50 mm for males). The most common indication for HRA was femoroacetabular impingement syndrome (n = 133), and avascular necrosis ( (n = 53). Mean postoperative HHS was 100 at two and five years. No dislocations occurred. A total of four hips (1.8%) required reoperation for resection of heterotopic ossification, removal of components for infection, and subsidence with loosening. The overall revision rate was 0.9%. Conclusion For younger patients with higher functional expectations and increased lifetime risk for revision, HRA is an excellent bone preserving intervention carrying low complication rates, revision rates, and excellent patient outcomes without lifetime restrictions allowing these patients to return to activity and sport. Thus, in younger male patients with end-stage hip disease and higher demands, referral to a high-volume HRA surgeon should be considered.
Collapse
Affiliation(s)
- Prem N. Ramkumar
- Hip Preservation Service, Hospital for Special Surgery, New York, New York, USA
- Long Beach Orthopaedic Institute, Long Beach, California, USA
| | - Hashim J. F. Shaikh
- Department of Orthopaedic Surgery, Rochester, University of Rochester Medical Center, Rochester, New York, USA
| | - Josh J. Woo
- Department of Orthopaedic Surgery, Brown University, Warren Alpert School of Medicine, Providence, Rhode Island, USA
| | - Heather S. Haeberle
- Hip Preservation Service, Hospital for Special Surgery, New York, New York, USA
| | - Michael Pang
- Department of Orthopaedic Surgery, Harvard Medical School, Cambridge, Massachusetts, USA
| | | |
Collapse
|
13
|
Huang Y, Yang Q, Wang Z, Pan Z, Zhang Y, Shi Z, Yang S. Comparisons of in-hospital complications between total hip arthroplasty and hip resurfacing arthroplasty. BMC Musculoskelet Disord 2023; 24:375. [PMID: 37170240 PMCID: PMC10173641 DOI: 10.1186/s12891-023-06487-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 05/03/2023] [Indexed: 05/13/2023] Open
Abstract
BACKGROUND Hip resurfacing arthroplasty (HRA) is a less common but effective alternative method to total hip arthroplasty (THA) for hip reconstruction. In this study, we investigated the incidences of in-hospital complications between patients who had been subjected to THA and HRA. METHODS The National Inpatient Sample data that had been recorded from 2005 to 2014 was used in this study. Based on the International Classification of Disease, Ninth Revision, Clinical Modification, patients who underwent THA or HRA were included. Data on demographics, preoperative comorbidities, length of hospital stay, total charges, and in-hospital mortality and complications were compared. Multiple logistic regression analysis was used to determine whether different surgical options are independent risk factors for postoperative complications. RESULTS A total of 537,506 THAs and 9,744 HRAs were obtained from the NIS database. Patients who had been subjected to HRA exhibited less preoperative comorbidity rates, shorter length of stay and extra hospital charges. Moreover, HRA was associated with more in-hospital prosthesis loosening. Notably, patients who underwent HRA were younger and presented less preoperative comorbidities but did not show lower incidences in most complications. CONCLUSIONS The popularity of HRA gradually reduced from the year 2005 to 2014. Patients who underwent HRA were more likely to be younger, male, have less comorbidities and spend more money on medical costs. The risk of in-hospital prosthesis loosening after HRA was higher. The HRA-associated advantages with regards to most in-hospital complications were not markedly different from those of THA. In-hospital complications of HRA deserve more attention from surgeons.
Collapse
Affiliation(s)
- Yuanyuan Huang
- School of Health, Dongguan Polytechnic, Dongguan, Guangdong, 523000, China
| | - Qinfeng Yang
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China
| | - Ziqi Wang
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China
| | - Zhijie Pan
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China
| | - Yang Zhang
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China.
| | - Zhanjun Shi
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China.
| | - Sheng Yang
- Division of Orthopaedic Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, 1838 Guangzhou Avenue, Guangzhou, Guangdong, 510515, China.
- The First School of Clinical Medicine, Southern Medical University, Guangzhou, Guangdong, 510515, China.
| |
Collapse
|
14
|
McBryde CW, Prakash R, Haddad FS. Hip resurfacing. Bone Joint J 2023; 105-B:467-470. [PMID: 37121587 DOI: 10.1302/0301-620x.105b5.bjj-2023-0015.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Affiliation(s)
- Callum W McBryde
- Young Adult Hip Unit, Royal Orthopaedic Hospital, Birmingham, UK
| | - Rohan Prakash
- Young Adult Hip Unit, Royal Orthopaedic Hospital, Birmingham, UK
| | - Fares S Haddad
- Department of Trauma and Orthopaedics, University College London Hospitals NHS Foundation Trust, London, UK
- The Bone & Joint Journal , London, UK
| |
Collapse
|
15
|
Ren R, Spaan J, Jordan A, Shafiro A, Su EP. Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty. J Arthroplasty 2023:S0883-5403(23)00356-X. [PMID: 37068566 DOI: 10.1016/j.arth.2023.04.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 04/05/2023] [Accepted: 04/08/2023] [Indexed: 04/19/2023] Open
Abstract
INTRODUCTION There is limited knowledge regarding usage of wearable technology to guide return to sport after hip resurfacing arthroplasty (HRA). This study evaluated the use of accelerometers to identify when symmetry is restored between operative and non-operative limbs. METHODS A total of 26 primary HRA patients performed five validated physical tests before, 3 and 6 months after HRA: broad jump, double leg vertical jump (DLVJ), hop test, lateral single leg jump (LSLJ), and vertical single leg jump (VSLJ). Impact load and average intensity data (g-force units) were collected using accelerometers. Strength data (pounds (lbs.)) for internal and external rotation was collected with a dynamometer. Univariate and correlation analyses analyzed interlimb asymmetries. RESULTS At pre-operation, there were significant impact load asymmetries for DLVJ (P=.008), hop test (P=.021), and LSLJ (P=.003), and intensity asymmetry for DLVJ (P=.010) and LSLJ (P=.003). At 3 months, there was impact load asymmetry for DLVJ (P=.005) and LSLJ (P=.005), and intensity asymmetry for broad jump (P=.020), hop test (P=.042), and LSLJ (P=.005). There were significant strength asymmetries at pre- and 3 months post-operation for internal (P=.013) and external rotation (P=.037). All significant asymmetries indicated the non-operative leg had greater output. No significant asymmetries were found for any exercises at 6 months post-operation. An increase in Harris Hip Score was significantly associated with a decrease in impact asymmetry (rs = -0.269, P=.006). DISCUSSION AND CONCLUSION Impact loads and strength reach interlimb symmetry at 6 months post-HRA. Wearable accelerometers provide useful metrics to distinguish limb asymmetries for recovery monitoring.
Collapse
Affiliation(s)
- Renee Ren
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, United States.
| | - Jonathan Spaan
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, United States
| | - Andrew Jordan
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, United States
| | - Alexander Shafiro
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, United States
| | - Edwin P Su
- Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, United States
| |
Collapse
|
16
|
Samuel LT, Zuke WA, Mahmood S, Munim MA, Alamir PB, Brooks PJ. Hip Resurfacing: A Single Surgeon U.S. Series With Minimum Ten-Year Follow-up. J Arthroplasty 2022; 37:1799-1808. [PMID: 35429614 DOI: 10.1016/j.arth.2022.04.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 03/14/2022] [Accepted: 04/08/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Metal-on-metal hip resurfacing is an alternative to total hip arthroplasty (THA). The aim of this study was to determine implant survivorship, analyze patient-reported outcomes measures and to determine patient satisfaction for patients who underwent metal-on-metal hip resurfacing at a large US academic institution by a single surgeon with a minimum of 10-year follow-up. METHODS Patients who underwent hip resurfacing from September 2006 through November 2009 were included. Patient demographics and variables were collected from a prospectively maintained institutional database and patients completed an additional questionnaire with patient-reported outcomes measures. RESULTS A total of 350 patients (389 hips) out of 371 (433 hips) with a minimum 10-year follow-up were successfully contacted (94.3% follow-up). Mean age was 53 years, 258 were male (73%). 377 out of 389 hips (96.9%) did not require additional surgery. Gender was significantly related to implant survivorship (males 99.0%, females 90.9%; P < .001). 330 patients (369 hips, 94.8%) were satisfied with their surgery. Males had higher proportion of satisfaction scores (P = .02) and higher modified Harris Hip Score (odds ratio = 2.63 (1.39, 4.98), P = .003). Median modified Harris Hip Score score for non-revised hips was 84.0 [80.0; 86.0] versus those requiring revision, 81.5 [74.0; 83.0], (P = .009). CONCLUSION At a minimum 10-year follow-up, hip resurfacing, using an implant with a good track record, demonstrates 99.0% survivorship in male patients with an average age of 52 years. We believe that the continued use of metal-on-metal hip resurfacing arthroplasty in this population is justified by both positive patient reported outcomes and survivorship.
Collapse
Affiliation(s)
- Linsen T Samuel
- Department of Orthopaedic Surgery, Orthopaedic & Rheumatological Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - William A Zuke
- Department of Orthopaedic Surgery, Orthopaedic & Rheumatological Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Sania Mahmood
- Department of Orthopaedic Surgery, Orthopaedic & Rheumatological Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| | - Mohammed A Munim
- School of Medicine, Case Western Reserve University, Cleveland, Ohio
| | | | - Peter J Brooks
- Department of Orthopaedic Surgery, Orthopaedic & Rheumatological Institute, Cleveland Clinic Foundation, Cleveland, Ohio
| |
Collapse
|
17
|
Martin H, Robinson PG, Maempel JF, Hamilton D, Gaston P, Safran MR, Murray IR. Pre- and intraoperative decision-making challenges in hip arthroscopy for femoroacetabular impingement. Bone Joint J 2022; 104-B:532-540. [PMID: 35491576 DOI: 10.1302/0301-620x.104b5.bjj-2021-1553.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
There has been a marked increase in the number of hip arthroscopies performed over the past 16 years, primarily in the management of femoroacetabular impingement (FAI). Insights into the pathoanatomy of FAI, and high-level evidence supporting the clinical effectiveness of arthroscopy in the management of FAI, have fuelled this trend. Arthroscopic management of labral tears with repair may have superior results compared with debridement, and there is now emerging evidence to support reconstructive options where repair is not possible. In situations where an interportal capsulotomy is performed to facilitate access, data now support closure of the capsule in selective cases where there is an increased risk of postoperative instability. Preoperative planning is an integral component of bony corrective surgery in FAI, and this has evolved to include computer-planned resection. However, the benefit of this remains controversial. Hip instability is now widely accepted, and diagnostic criteria and treatment are becoming increasingly refined. Instability can also be present with FAI or develop as a result of FAI treatment. In this annotation, we outline major current controversies relating to decision-making in hip arthroscopy for FAI. Cite this article: Bone Joint J 2022;104-B(5):532-540.
Collapse
Affiliation(s)
- Hannah Martin
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.,Department of Orthopaedic Surgery, The University of Edinburgh, Edinburgh, UK
| | - Patrick G Robinson
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.,Department of Orthopaedic Surgery, The University of Edinburgh, Edinburgh, UK
| | | | - David Hamilton
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.,Department of Orthopaedic Surgery, The University of Edinburgh, Edinburgh, UK.,School of Health and Social Care, Edinburgh Napier University, Edinburgh, UK
| | - Paul Gaston
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.,Department of Orthopaedic Surgery, The University of Edinburgh, Edinburgh, UK
| | - Marc R Safran
- Department of Orthopaedic Surgery, Stanford University, Redwood City, California, USA
| | - Iain R Murray
- Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.,Department of Orthopaedic Surgery, The University of Edinburgh, Edinburgh, UK
| |
Collapse
|
18
|
[Translated article] Improvement of survival after 10 years with the Durom-type hip resurfacing prosthesis in selected patients: Experience of a public university hospital. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022. [DOI: 10.1016/j.recot.2021.09.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
19
|
Marqués López F, Cuenca Llavall M, Mestre Cortadellas C, Tey Pons M, León García A. Mejoría de la supervivencia a los 10 años con la prótesis de recubrimiento de cadera tipo Durom en pacientes seleccionados. Experiencia de un hospital público universitario. Rev Esp Cir Ortop Traumatol (Engl Ed) 2022; 66:182-188. [DOI: 10.1016/j.recot.2021.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/30/2021] [Accepted: 09/07/2021] [Indexed: 10/19/2022] Open
|
20
|
Wang Q, An J, Zhang W, Yang Z, Zhao X, Kang P. Core Decompression Prevents Progression of Asymptomatic Type C Osteonecrosis of Femoral Head According to the Japanese Investigation Committee Classification: A Retrospective Study. Orthop Surg 2022; 14:851-859. [PMID: 35434904 PMCID: PMC9087457 DOI: 10.1111/os.13213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 12/15/2021] [Accepted: 12/20/2021] [Indexed: 02/05/2023] Open
Affiliation(s)
- Qiu‐ru Wang
- Department of Orthopaedics Surgery West China Hospital, Sichuan University Chengdu China
| | - Jing‐jing An
- Public Laboratory Technology Center West China Hospital, Sichuan University Chengdu China
| | - Wan‐li Zhang
- Public Laboratory Technology Center West China Hospital, Sichuan University Chengdu China
| | - Zhou‐yuan Yang
- Department of Orthopaedics Surgery West China Hospital, Sichuan University Chengdu China
| | - Xin Zhao
- Department of Orthopaedics Surgery West China Hospital, Sichuan University Chengdu China
| | - Peng‐de Kang
- Department of Orthopaedics Surgery West China Hospital, Sichuan University Chengdu China
| |
Collapse
|
21
|
Girard J, Epinette JA, Martinot P, Dartus J. French hip resurfacing registry: A study of 1650 cases. Orthop Traumatol Surg Res 2022; 108:103087. [PMID: 34597828 DOI: 10.1016/j.otsr.2021.103087] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 01/07/2021] [Accepted: 02/01/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND Hip resurfacing has been the focus of many evaluations based on international registries but, to date, no prospective studies have evaluated this procedure in France. In 2015, the French Society for Orthopaedics and Traumatology (SoFCOT) and the French Hip and Knee Society concluded an agreement with the French Medicines Agency (ANSM) and French National Health Authority (HAS) to establish an exhaustive observational hip resurfacing registry. The primary objective of this study was to evaluate the hip resurfacing survival rate since the creation of the registry 5 years ago. The secondary objectives were to evaluate the clinical, functional, and radiological outcomes of hip resurfacing and to check the absence of specific complications related to this implant. HYPOTHESIS The hypothesis was that the registry survival rate was below 0.5% per year. METHODS Since 2015, data from all patients undergoing hip resurfacing were collected into a monitored database using the software suite OrthoWave. The following were collected for each patient: demographics, anthropometric characteristics, clinical parameters (Postel Merle d'Aubigné score, Harris Hip Score, Oxford Hip Score, and UCLA Activity Score), and radiological findings. Completeness of data collection was checked once a year. RESULTS In total, 1650 hip resurfacings in 1506 patients (1409 males and 97 females) with a mean age of 50.7 years (range, 17-70 years) were included. Mean follow-up was 3.8 years (range, 2-4.8 years). Mean completeness of data recording was 98.2%. All clinical scores improved significantly. Hip revision was required for 7 (0.4%) complications including 4 femoral neck fractures, 1 aseptic lymphocyte-dominant vasculitis-associated lesion with a large joint effusion, 1 femoral component loosening, and 1 delayed sepsis requiring bipolar removal. At 5 years, the survival rate without hip revision for any cause was 99.6% (95% confidence interval, 99.3-100%). DISCUSSION The short-term outcomes of patients in the French registry are encouraging in terms of complication and surgical revision rates. The near absence of complications related to metal-on-metal bearing surfaces demonstrates that the criteria used in France (at least 48mm head diameter, use of implants for which long-term data are available, and specific training of surgeons) ensure successful long-term outcomes. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Julien Girard
- Service d'orthopédie C, hôpital Salengro, CHRU de Lille, Lille, France; EA 7369 - URePSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, University Lille, University Artois, University Littoral Côte d'Opale, 59000 Lille, France.
| | | | - Pierre Martinot
- Service d'orthopédie C, hôpital Salengro, CHRU de Lille, Lille, France
| | - Julien Dartus
- Service d'orthopédie C, hôpital Salengro, CHRU de Lille, Lille, France
| | | |
Collapse
|
22
|
LeBrun DG, Shen TS, Bovonratwet P, Morgenstern R, Su EP. Hip Resurfacing vs Total Hip Arthroplasty in Patients Younger than 35 Years: A Comparison of Revision Rates and Patient-Reported Outcomes. Arthroplast Today 2021; 11:229-233. [PMID: 34692960 PMCID: PMC8516816 DOI: 10.1016/j.artd.2021.09.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2021] [Revised: 08/24/2021] [Accepted: 09/07/2021] [Indexed: 11/24/2022] Open
Abstract
Background Hip resurfacing arthroplasty (HRA) and total hip arthroplasty (THA) are two treatment options for end-stage degenerative hip conditions. The objective of this single-center retrospective cohort study was to compare implant survival and patient-reported outcomes (PROs) in young patients (≤35 years) who underwent HRA or THA. Methods All patients aged 35 years or younger who underwent HRA or THA with a single high-volume arthroplasty surgeon between 2004 and 2015 were reviewed. The sample included 33 THAs (26 patients) and 76 HRAs (65 patients). Five-year implant survival and minimum 2-year PROs were compared between patient cohorts. Results Three patients in the THA group (9%) were revised within 5 years for instability (n = 1), squeaking (n = 1), or squeaking with a ceramic liner fracture (n = 1). No patients who underwent HRA were revised. The University of California, Los Angeles, activity score, modified Harris Hip score, and Hip Dysfunction and Osteoarthritis Outcome Scores for Joint Replacement increased by 74%, 64%, and 49%, respectively, among all patients. Compared to the HRA cohort, patients who underwent THA had lower preoperative and postoperative University of California, Los Angeles, activity, modified Harris Hip score, and Hip Dysfunction and Osteoarthritis Outcome Scores for Joint Replacement scores, yet there were no differences in the absolute improvements in any of the three measures between the two groups. Conclusions Excellent functional outcomes were seen in young patients undergoing either HRA or THA. Although young patients undergoing THA started at lower preoperative baseline and postoperative PROs than patients undergoing HRA, both groups improved by an equal amount after surgery, suggesting that both HRA and THA afford a similar degree of potential improvement in a young population.
Collapse
Affiliation(s)
- Drake G LeBrun
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Tony S Shen
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Patawut Bovonratwet
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Rachelle Morgenstern
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| | - Edwin P Su
- Department of Orthopaedic Surgery, Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
23
|
Zawadzki P. Proposal for a Novel Abrasive Machining Method for Preparing the Surface of Periarticular Tissue during Orthopedic Surgery on Hip Joints. J Funct Biomater 2021; 12:50. [PMID: 34564199 PMCID: PMC8482268 DOI: 10.3390/jfb12030050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/06/2021] [Accepted: 09/06/2021] [Indexed: 01/21/2023] Open
Abstract
Drilling, cutting, and milling are the most common methods used in orthopedic surgery. However, popular machining methods do not obtain the complex shape of the periarticular tissue surfaces, increasing operation time and patient recovery. This paper reports an attempt to research a novel design of a machining process for surgical procedures. A device using abrasion machining based on mechanical erosion was proposed. Machining uses an undefined geometry of the cutting grains to cut tissue in any direction during oscillatory tool movement. This new concept is based on a cylindrical abrasive device made of brown fused alumina and silicon carbide grains deposited with an epoxy resin binder on the surface of a polyamide shaft. The best results in terms of machining efficiency were obtained for grains of the BFA80 type. Cutting experiments with different values in terms of cutting speed, granulation of the abrasive grains, pressure forces, and machining scope showed that the proposed concept, by developing the shape of the device, allows for penetration of the tissue structure. The research shows the possibility of using the proposed method during periarticular tissue machining.
Collapse
Affiliation(s)
- Paweł Zawadzki
- Faculty of Mechanical Engineering, Poznan University of Technology, Maria Sklodowska-Curie Square, 60-965 Poznan, Poland
| |
Collapse
|
24
|
Suraci AB, Bhullar RS, Dobransky JS, Beaulé PE. Hueter Anterior Approach for Metal-on-Metal Hip Resurfacing Arthroplasty: 555 Cases at a Minimum Five-Year Follow-Up. J Arthroplasty 2021; 36:3200-3208. [PMID: 33992480 DOI: 10.1016/j.arth.2021.04.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 04/06/2021] [Accepted: 04/19/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Purpose of this study was to determine implant survivorship and resultant outcomes, including modes of failure, for metal-on-metal hip resurfacing through the Hueter anterior approach (HAA). METHODS Retrospective review of cases from 2006 to 2015, resulted in 555 metal-on-metal hip resurfacing via HAA, mean age 49.4 ± 6.9 years and mean BMI 28.1 ± 5.3. Kaplan-Meier curves were used to assess implant survivorship. Evaluation of technique was based on radiographic assessment of component position at 6 weeks. Patient-reported outcome measures were assessed using 12-Item Short Form Survey 12, University of California Los Angeles activity, Western Ontario and McMaster Universities Osteoarthritis Index, and hip disability osteoarthritis outcome scores. RESULTS At a mean follow-up of 9.18 years, survivorship was 95.0% at 5 years (95% CI: 93.2-96.8 years) and 92.5% at 10 years (95% CI: 90.0-95.0 years); men at 96.1% (95% CI: 94.3-97.9) and 93.8% (95% CI: 91.1-96.5), and women at 88.8% (95% CI: 81.9-95.7) and 85.6% (95% CI: 77.6-93.6), 5 and 10 years, respectively (P = .033). There were 37 revisions to total hips (7%) at a mean time of 3.3 years (SD 2.7). Indications for revision were aseptic loosening of acetabular (n = 12) and femoral component (n = 7) and pseudotumor (n = 6). Radiographic parameters were respectable and consistent, median acetabular inclination angle 41.2° and femoral stem shaft angle 137.7°. Patient-reported outcome measure scores significantly improved and remained stable at 2 and 5 years postoperatively. CONCLUSION Although choice of surgical approach should always be based on surgeon's technical expertise, this study has shown that HAA is safe and effective for hip resurfacing. Mindful attention to long-term metal ion exposure must still be considered.
Collapse
Affiliation(s)
- Alison B Suraci
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON
| | | | | | - Paul E Beaulé
- Division of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, ON; Scientist, The Ottawa Hospital Research Institute, Ottawa, ON
| |
Collapse
|
25
|
Su EP, Ho H, Bhal V, Housman LR, Masonis JL, Noble JW, Hopper RH, Engh CA. Results of the First U.S. FDA-Approved Hip Resurfacing Device at 10-Year Follow-up. J Bone Joint Surg Am 2021; 103:1303-1311. [PMID: 33999875 DOI: 10.2106/jbjs.20.01886] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The BIRMINGHAM HIP Resurfacing (BHR) system is a metal-on-metal hip implant system approved by the U.S. Food and Drug Administration in 2006. The approval required a multicenter, prospective, post-market-approval study. Our purpose is to report the current results at 10 years of follow-up. METHODS Between October 2006 and December 2009, 280 primary BHR procedures were performed at 5 sites. Outcome measures included Kaplan-Meier survivorship, reasons for revision, radiographic component stability and osteolysis, Harris hip scores, and metal levels including cobalt and chromium. The mean age at the time of the procedure was 51.3 ± 7.1 years, 74% (206) of 280 BHRs were implanted in male patients, the mean body mass index was 27.8 ± 4.4 kg/m2, and 95% (265) of 280 hips had a primary diagnosis of osteoarthritis. The mean follow-up among all 280 hips was 9.0 ± 2.5 years. Prior to 10-year follow-up, 20 hips were revised and 5 patients representing 5 hips had died. Among the remaining 255 hips, 218 (85%) met the minimum follow-up of 10 years. RESULTS The 10-year survival free from all-cause component revision was 92.9% (95% confidence interval [CI], 89.8% to 96.1%) for all hips and 96.0% (95% CI, 93.1% to 98.9%) among male patients <65 years old at the time of the procedure. Reasons for revision included femoral loosening (n = 5), femoral neck fracture (n = 3), pseudotumor (n = 3), osteolysis (n = 2), and acetabular loosening (n = 1), as well as 6 revisions for a combination of pain, noise, or metal levels. Among unrevised hips, the median Harris hip score improved from preoperatively (59) to 1 year postoperatively (99; p < 0.001) and remained stable through 10 years postoperatively (99; p = 0.08). Radiographically, 5% (10) of 218 unrevised hips had osteolysis with no component migration. Median metal levels had increased at 1 year postoperatively (cobalt: from 0.12 ppb preoperatively to 1.5 ppb at 1 year postoperatively, p < 0.001; chromium: from 0.6 ppb preoperatively to 1.7 ppb at 1 year postoperatively, p < 0.001), then remained stable through 5 years before slightly decreasing at 10 years postoperatively (cobalt: 1.3 ppb, p < 0.001; chromium: 1.4 ppb, p < 0.001). CONCLUSIONS This prospective, multicenter, post-market-approval study demonstrated that the BHR implant system is safe and effective through 10 years of follow-up, particularly among young male patients. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Edwin P Su
- Hospital for Special Surgery, New York, NY
| | - Henry Ho
- Anderson Orthopaedic Research Institute, Alexandria, Virginia
| | | | | | - John L Masonis
- OrthoCarolina Hip and Knee Center, Charlotte, North Carolina
| | | | - Robert H Hopper
- Anderson Orthopaedic Research Institute, Alexandria, Virginia
| | - C Anderson Engh
- Anderson Orthopaedic Clinic and Inova Mount Vernon Joint Replacement Center, Alexandria, Virginia
| |
Collapse
|
26
|
Brown TS. Considering the Use of Metal-on-Metal Hip Resurfacing in Young Male Patients: Commentary on an article by Edwin P. Su, MD, et al.: "Results of the First U.S. FDA-Approved Hip Resurfacing Device at 10-Year Follow-up". J Bone Joint Surg Am 2021; 103:e56. [PMID: 34260444 DOI: 10.2106/jbjs.21.00515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Timothy S Brown
- Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| |
Collapse
|
27
|
Subchondral Bone Relative Area and Density in Human Osteoarthritic Femoral Heads Assessed with Micro-CT before and after Mechanical Embedding of the Innovative Multi-Spiked Connecting Scaffold for Resurfacing THA Endoprostheses: A Pilot Study. J Clin Med 2021; 10:jcm10132937. [PMID: 34208953 PMCID: PMC8268800 DOI: 10.3390/jcm10132937] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 06/27/2021] [Accepted: 06/28/2021] [Indexed: 12/19/2022] Open
Abstract
The multi-spiked connecting scaffold (MSC-Scaffold) prototype is the essential innovation in the fixation of components of resurfacing total hip arthroplasty (THRA) endoprostheses in the subchondral trabecular bone. We conducted the computed micro-tomography (micro-CT) assessment of the subchondral trabecular bone microarchitecture before and after the MSC-Scaffold embedding in femoral heads removed during long-stem endoprosthesis total hip arthroplasty (THA) of different bone densities from 4 patients with hip osteoarthritis (OA). The embedding of the MSC-Scaffold in subchondral trabecular bone causes the change in its relative area (BA/TA, bone area/total area ratio) ranged from 18.2% to 24.7% (translating to the calculated density ρB relative change 11.1–14.4%, and the compressive strength S relative change 75.3–122.7%) regardless of its initial density (before the MSC-Scaffold embedding). The densification of the trabecular microarchitecture of subchondral trabecular bone due to the MSC-Scaffold initial embedding gradually decreases with the increasing distance from the apexes of the MSC-Scaffold’s spikes while the spatial extent of this subchondral trabecular bone densification ranged from 1.5 to 2.5 mm (which is about half the height of the MSC-Scaffold’s spikes). It may be suggested, despite the limited number of examined femoral heads, that: (1) the magnitude of the effect of the MSC-Scaffold embedding on subchondral trabecular bone densification may be a factor contributing to the maintenance of the MSC-Scaffold also for decreased initial bone density values, (2) the deeper this effect of the subchondral trabecular bone densification, the better strength of subchondral trabecular bone, and as consequence, the better post-operative embedding of the MSC-Scaffold in the bone should be expected.
Collapse
|
28
|
Morse KW, Premkumar A, Zhu A, Morgenstern R, Su EP. Return to Sport After Hip Resurfacing Arthroplasty. Orthop J Sports Med 2021; 9:23259671211003521. [PMID: 33997077 PMCID: PMC8113959 DOI: 10.1177/23259671211003521] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Accepted: 12/15/2020] [Indexed: 11/17/2022] Open
Abstract
Background Femoroacetabular impingement and degenerative hip osteoarthritis (OA) affect athletes across a wide variety of sports. Hip resurfacing arthroplasty (HRA) has emerged as a surgical treatment for active individuals with end-stage hip OA to provide pain relief and allow return to high-impact activities. Return to professional sports after HRA has not been well characterized. Purpose/Hypothesis The aim of this study was to report on a series of elite athletes in a variety of sports who underwent HRA. We hypothesized that professional and elite-level athletes would be able to return to sports after HRA for end-stage hip OA. Study Design Case series; Level of evidence, 4. Methods A retrospective case series was conducted on professional athletes who underwent HRA at a single institution between 2007 and 2017. All surgeries were performed by a single surgeon using the posterolateral approach. Athletes' return to play and sport-specific performance statistics were obtained using self-reported and publicly available data sources. Athletes were matched to an age- and performance-based cohort to determine changes in performance-based metrics. Results Eight professional athletes were identified, including 2 baseball pitchers, 1 ice hockey defenseman, 1 foil fencer, 1 men's doubles tennis player, 1 basketball player, 1 ultramarathoner, and 1 Ironman triathlete. All 8 patients returned to sports; 6 of 8 (75%) patients were able to return for at least 1 full season at a professional level after surgery. There were no significant differences between performance statistics for athletes who returned to play and their preoperative performance measures for the years leading up to surgery or the age- and performance-matched cohort. Conclusion HRA remains a surgical alternative for end-stage hip OA in young, high-impact, active patients. While the primary goals of surgery are pain control and quality of life improvement, it is possible to return to elite-level sporting activity after HRA.
Collapse
Affiliation(s)
- Kyle W Morse
- Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Ajay Premkumar
- Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Andrew Zhu
- Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, New York, USA
| | - Rachelle Morgenstern
- Department of Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| | - Edwin P Su
- Department of Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York, USA
| |
Collapse
|
29
|
Eremina GM, Smolin AY. Risk assessment of resurfacing implant loosening and femur fracture under low-energy impacts taking into account degenerative changes in bone tissues. Computer simulation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 200:105929. [PMID: 33450504 DOI: 10.1016/j.cmpb.2021.105929] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 12/31/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE Degenerative diseases of the musculoskeletal system significantly reduce the quality of human life. Hip resurfacing is used to treat degenerative diseases in the later stages. After surgery, there is a risk of endoprosthesis loosening and low-energy fracture during daily physical activity. Computer modeling is a promising way to predict the optimal low-energy loads that do not lead to bone destruction. This paper aims to study numerically the mechanical behavior of the proximal femur, amenable to degenerative changes and subjected to hip resurfacing under low-energy impact equivalent to physiological loads. METHODS A numerical model of the mechanical behavior of the femur after hip resurfacing arthroplasty under low-energy impacts equivalent to physiological loads is presented. The model is based on the movable cellular automaton method (discrete elements), where the mechanical behavior of bone tissue is described using the Biot poroelasticity accounting for the presence and transfer of interstitial biological fluid. RESULTS For the first time, it is shown that a poroelastic model allows predicting the service life of endoprostheses, taking into account the individual characteristics of the bone tissues amenable to various degenerative diseases. The obtained results indicate that the changes in the bone properties have a significant influence on the critical forces corresponding to the first appearance of microcracks and the fracture formation. At the same time, their effect on the type of fracture is negligible. A much more impact on the type of fracture has the kinematic and dynamic conditions of the exposure. CONCLUSIONS The obtained results show the promise of using the proposed model for predicting the operational resource of resurfacing endoprostheses, taking into account the physiological features of the structure of the patient's bone tissues.
Collapse
Affiliation(s)
- Galina M Eremina
- Institute of Strength Physics and Materials Science of SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634055, Russia.
| | - Alexey Yu Smolin
- Institute of Strength Physics and Materials Science of SB RAS, 2/4, pr. Akademicheskii, Tomsk, 634055, Russia.
| |
Collapse
|
30
|
Zhen P, Chang Y, Yue H, Chen H, Zhou S, Liu J, He X. Primary total hip arthroplasty using a short bone-conserving stem in young adult osteoporotic patients with Dorr type C femoral bone. J Orthop Surg Res 2021; 16:17. [PMID: 33413495 PMCID: PMC7789779 DOI: 10.1186/s13018-020-01985-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2020] [Accepted: 09/23/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Dorr type C femoral bone exhibits a wide, stovepipe-shaped femoral canal, and thin cortices in the proximal femur. Dorr C bone combined with severe osteoporosis is an important challenge in primary hip arthroplasty. In this study, we assessed the effects of short metaphyseal fitting cementless stems on preformatted primary total hip arthroplasties in young adult osteoporotic patients with this femoral presentation. METHODS A total of 42 hip arthroplasties were performed in 35 young patients (range 20 to 36 years) using a short Tri-lock bone preservation metaphyseal-fitting cementless femoral component between 2012 and 2017. The mean age at surgery of the 27 male (33 hips) and 8 female (9 hips) patients was 27.5 years (range 20.3 to 35.8 years). The mean body mass index (BMI) was 20.2 kg/m2 (range, 16.8-23.2 kg/m2). According to Dorr's criteria, all 42 femora were classified as type C bone and all femurs suffered from severe osteoporosis (Singh index ≤ 3). RESULTS The mean follow-up period was 5.5 years (range 3.0 to 8.0 years). The clinical and functional results improved for the Harris hip score, WOMAC, and UCLA activity scores. The Harris Hip score improved from 48.0 ± 8.0 (range 38.0 to 61.0) preoperatively to 87.0 ± 9.0 (range 77.0 to 92.0) at 12 months after surgery and 91.0 ± 8.0 (range 85.0 to 98.0) at final follow-up. The preoperative UCLA activity score was 3.0 ± 0.5 points (range, 1.0-4.0 points), which significantly improved to 7.5 ± 0.7 points (range 6.0 to 8.0 points) at the final follow-up. No patient exhibited thigh pain at the final follow-up. The mean stem-to-canal fill percentages were 97% ± 2.1% (anteroposterior view at midstem). For stem alignment, 40 hips (95.2%) of the femoral stem were positioned neutrally to 3° of varus with reference to the femoral shaft axis. The remaining two were positioned at 4° varus to 4° valgus. Radiographic evaluation showed good osteointegration of the implants in follow-up. CONCLUSIONS Based on the tapered-wedge design and proximal porous coating, the shortened tapered conventional stem can achieve reliable stability through neck filling and metaphyseal fixation, which does not depend on the isthmus hoop stress. This stem was suitable in severe osteoporotic patients with type C bones in young adults who presented with a correspondingly straightened femoral canal with a wide isthmus and thin cortex.
Collapse
Affiliation(s)
- Ping Zhen
- Department of Joint Surgery, Institute of Orthopedics, The 940th Hospital of PLA Joint Logistics Support Force, South Binhe Road, No. 333, Lanzhou City, Gansu Province, 730050, PR China
| | - Yanfeng Chang
- Department of Joint Surgery, Institute of Orthopedics, The 940th Hospital of PLA Joint Logistics Support Force, South Binhe Road, No. 333, Lanzhou City, Gansu Province, 730050, PR China
| | - Heng Yue
- Department of Joint Surgery, Institute of Orthopedics, The Dingxi People's Hospital, Anding Road, Anding District, No. 22, Dingxi City, Gansu Province, 730050, PR China
| | - Hui Chen
- Department of Joint Surgery, Institute of Orthopedics, The 940th Hospital of PLA Joint Logistics Support Force, South Binhe Road, No. 333, Lanzhou City, Gansu Province, 730050, PR China
| | - Shenghu Zhou
- Department of Joint Surgery, Institute of Orthopedics, The 940th Hospital of PLA Joint Logistics Support Force, South Binhe Road, No. 333, Lanzhou City, Gansu Province, 730050, PR China
| | - Jun Liu
- Department of Joint Surgery, Institute of Orthopedics, The Second Affiliated Hospital of Xi'an Jiaotong University, Xiwu Road, No. 157, Xi'an City, Shaanxi Province, 730050, PR China.
| | - Xiaole He
- Department of General Practice, Xijing Hospital of Air Force Military Medical University, Xi' an, 710032, China.
| |
Collapse
|
31
|
Soin S, El-Shaar R, Taylor A, Ketz J. Periprosthetic Intertrochanteric Fracture between Hip Resurfacing and Retrograde Nail. Arthroplast Today 2020; 6:682-685. [PMID: 32875019 PMCID: PMC7451880 DOI: 10.1016/j.artd.2020.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 07/07/2020] [Accepted: 07/08/2020] [Indexed: 11/30/2022] Open
Abstract
Periprosthetic femur fractures present a growing worldwide challenge for orthopaedic surgeons. Fractures around a hip resurfacing implant create unique management problems. When considering fixation, there can be limited options for ideal stabilization and some require creative constructs. We present an interesting case of a periprosthetic intertrochanteric femur fracture between a hip resurfacing implant and retrograde intramedullary nail.
Collapse
Affiliation(s)
- Sandeep Soin
- Department of Orthopeadic Surgery, University of Rochester, Rochester, NY, USA
| | - Rami El-Shaar
- Department of Orthopeadic Surgery, University of Rochester, Rochester, NY, USA
| | - Aaron Taylor
- Department of Orthopeadic Surgery, University of Rochester, Rochester, NY, USA
| | - John Ketz
- Department of Orthopeadic Surgery, University of Rochester, Rochester, NY, USA
| |
Collapse
|
32
|
Fassihi SC, Mortman R, Shalkevich J, Lee D, Stoll WT, Thakkar S. Total Hip Arthroplasty for the Sequelae of Femoral Neck Fractures in the Pediatric Patient. Arthroplast Today 2020; 6:296-304. [PMID: 32509942 PMCID: PMC7264979 DOI: 10.1016/j.artd.2020.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Revised: 04/10/2020] [Accepted: 04/15/2020] [Indexed: 11/26/2022] Open
Abstract
Although rare, total hip arthroplasty (THA) may be indicated in pediatric patients with degenerative changes of the hip joint after previous trauma. To illustrate management principles in this patient population, this study describes the case of a 15-year-old female who sustained bilateral femoral neck fractures after a generalized tonic-clonic seizure, an atypical, low-energy mechanism for this injury. These fractures were not diagnosed until 14 weeks after the seizure episode, at which point they had progressed to nonunion on the left side, malunion on the right side, and degenerative hip joint changes were developing bilaterally. Bilateral THA was ultimately performed, and the patient had favorable outcomes at 1 year postoperatively. In determining the optimal management strategy for such patients, a multidisciplinary approach should be used, with input from the patient’s family, pediatrician, pediatric endocrinologist, pediatric orthopaedic surgeon, and adult reconstruction surgeon. From a surgical standpoint, this report highlights the importance of selecting the appropriate bearing surfaces, broaching technique, mode of implant fixation, and implant features when performing THA in the active pediatric patient.
Collapse
Affiliation(s)
- Safa C Fassihi
- Department of Orthopaedic Surgery, George Washington University, Washington, DC, USA
| | - Ryan Mortman
- Department of Orthopaedic Surgery, George Washington University, Washington, DC, USA
| | - Jacob Shalkevich
- Department of Orthopaedic Surgery, George Washington University, Washington, DC, USA
| | - Danny Lee
- Department of Orthopaedic Surgery, George Washington University, Washington, DC, USA
| | - William T Stoll
- Department of Orthopaedic Surgery, George Washington University, Washington, DC, USA
| | - Savyasachi Thakkar
- Department of Orthopaedic Surgery, Georgetown University MedStar Health, Washington, DC, USA
| |
Collapse
|
33
|
Park CW, Lim SJ, Kim JH, Park YS. Hip resurfacing arthroplasty for osteonecrosis of the femoral head: Implant-specific outcomes and risk factors for failure. J Orthop Translat 2020; 21:41-48. [PMID: 32071874 PMCID: PMC7016032 DOI: 10.1016/j.jot.2019.12.005] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 11/06/2019] [Accepted: 12/10/2019] [Indexed: 12/03/2022] Open
Abstract
Background Hip resurfacing arthroplasty (HRA) may be a suitable option for treating osteonecrosis of the femoral head (ONFH). However, concerns regarding the extent of osteonecrosis, amount of defect under the prosthesis, and implant-related complications remain. This study aimed to report implant-specific outcomes and risk factors for failure of HRA in ONFH. Methods A total of 202 HRAs (166 patients) performed by a single surgeon were investigated. The stage, size, and location of ONFH were evaluated using preoperative radiographs and magnetic resonance images. Clinical, radiographic results, and serum metal concentrations of articular surface replacement (ASR) and non-ASR devices were compared. Logistic regression analysis was performed to identify the contributors of failures. The mean follow-up duration was 10.6 years. Results Twenty-six hips (12.9%) were operated with Birmingham Hip Resurfacing (BHR), 99 (49.0%) with ASR, and 77 (38.1%) with Conserve Plus. The mean Harris Hip Score improved from 52.1 to 93.2 at the final follow-up (P < 0.001). Revision-free survivorships of non-ASR and ASR implants were 99.0% and 82.4%, respectively (P < 0.001). In multivariate analysis, the use of ASR prosthesis, greater combined necrotic angle, and smaller head size were associated with revision surgery. A large combined necrotic angle was the only independent risk factor for mechanical failure at the femoral side (P = 0.029). Conclusion HRA for ONFH using BHR and Conserve Plus implants demonstrated favourable clinical outcomes with high revision-free survival rates at 10 years. However, care should be taken for large necrotic lesions that can lead to femoral neck fracture or aseptic femoral loosening. The translational potential of this article This study suggests HRA performed for appropriately selected patients with ONFH can show excellent long-term clinical results. Therefore, HRA should remain as one of the treatment options for ONFH, and further development of HRA implants should be continued.
Collapse
Affiliation(s)
- Chan-Woo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Seung-Jae Lim
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Joo-Hwan Kim
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | - Youn-Soo Park
- Department of Orthopaedic Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| |
Collapse
|
34
|
Abstract
Aims The aim of this study was to assess the functional gain achieved following hip resurfacing arthroplasty (HRA). Patients and Methods A total of 28 patients (23 male, five female; mean age, 56 years (25 to 73)) awaiting Birmingham HRA volunteered for this prospective gait study, with an age-matched control group of 26 healthy adults (16 male, ten female; mean age, 56 years (33 to 84)). The Oxford Hip Score (OHS) and gait analysis using an instrumented treadmill were used preoperatively and more than two years postoperatively to measure the functional change attributable to the intervention. Results The mean OHS improved significantly from 27 to 46 points (p < 0.001) at a mean of 29 months (12 to 60) after HRA. The mean metal ion levels at a mean 32 months (13 to 60) postoperatively were 1.71 (0.77 to 4.83) µg/l (ppb) and 1.77 (0.68 to 4.16) µg/l (ppb) for cobalt and chromium, respectively. When compared with healthy controls, preoperative patients overloaded the contralateral good hip, limping significantly. After HRA, patients walked at high speeds, with symmetrical gait, statistically indistinguishable from healthy controls over almost all characteristics. The control group could only be distinguished by an increased push-off force at higher speeds, which may reflect the operative approach. Conclusion Patients undergoing HRA improved their preoperative gait pattern of a significant limp to a symmetrical gait at high speeds and on inclines, almost indistinguishable from normal controls. HRA with an approved device offers substantial functional gains, almost indistinguishable from healthy controls. Cite this article: Bone Joint J 2019;101-B:1423–1430.
Collapse
Affiliation(s)
- Anatole V Wiik
- Imperial College London, MSK Lab, Department of Surgery and Cancer, Charing Cross Hospital, London, UK
| | - Rhiannon Lambkin
- Imperial College London, MSK Lab, Department of Surgery and Cancer, Charing Cross Hospital, London, UK
| | - Justin P Cobb
- Imperial College London, MSK Lab, Department of Surgery and Cancer, Charing Cross Hospital, London, UK
| |
Collapse
|