1
|
Cochrane NH, Kim BI, Holland CT, Seyler TM, Ryan SP, Bolognesi MP, Wellman SS. Ultracongruent Polyethylene Liners Do Not Affect Survival of Total Knee Arthroplasty for Valgus Deformity. J Arthroplasty 2024; 39:S183-S187. [PMID: 38355064 DOI: 10.1016/j.arth.2024.02.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/16/2024] Open
Abstract
BACKGROUND Valgus knee deformity is observed in nearly 10% of patients undergoing total knee arthroplasty (TKA). The degree of polyethylene constraint required to balance a valgus knee remains controversial, and historically, posterior-stabilized (PS) designs have been favored. This study evaluated the survivorship of TKA done in valgus knees based on implant design and specifically compared posterior-stabilized (PS) and ultracongruent (UC) liners. METHODS A total of 549 primary TKAs performed on valgus knees by fellowship-trained arthroplasty surgeons from 2013 to 2019 were reviewed. Demographics, comorbidities, degrees of preoperative deformity, implants used, and all-cause revisions until final follow-up were recorded. Cox regression analyses evaluated survival to all-cause revision in each cohort. The mean follow-up was 4.9 years (range, 2 to 9). RESULTS There were 403 UC liners compared to 146 PS liners. There was no difference in patient age (68 versus 67 years; P = .30), body mass index (30.9 versus 30.4; P = .36), or degree of deformity (8.6 versus 8.8 degrees; P = .75) between the cohorts. At final follow-up, there were 5 revisions in the PS cohort (3.4%) versus 11 revisions in the UC cohort (2.7%) (P = .90). The most common reason for revision in both cohorts was periprosthetic joint infection (4 PS; 8 UC). Multivariable regression analyses controlling for age, body mass index, Elixhauser comorbidity score, sex, and degree of deformity demonstrated UC polyethylene liners were not associated with revision (hazard ratio 0.76; 95% confidence interval [CI] 0.26 to 2.21; P = .62). There was no difference in eight-year survivorship to all-cause revision, including aseptic and septic failure. CONCLUSIONS Alternative polyethylene liners from the historically utilized PS liners for TKA for valgus deformity did not reduce survivorship. With modern polyethylene designs, UC inserts can be utilized for this deformity without increasing the risk of failure.
Collapse
Affiliation(s)
- Niall H Cochrane
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Billy I Kim
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Christopher T Holland
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Thorsten M Seyler
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Sean P Ryan
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Michael P Bolognesi
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| | - Samuel S Wellman
- Department of Orthopaedic Surgery, Duke University Medical Center, Durham, North Carolina
| |
Collapse
|
2
|
Lizcano JD, Molloy IB, Kohli M, Yakkanti RR, Tarabichi S, Austin MS. Ultracongruent Versus Posterior-Stabilized Polyethylene: No Difference in Anterior Knee Pain but Decreased Noise Generation. J Am Acad Orthop Surg 2024:00124635-990000000-01043. [PMID: 39018667 DOI: 10.5435/jaaos-d-24-00379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Accepted: 05/22/2024] [Indexed: 07/19/2024] Open
Abstract
BACKGROUND Noise generation and anterior knee pain can occur after primary total knee arthroplasty (TKA) and may affect patient satisfaction. Polyethylene design in cruciate-sacrificing implants could be a variable influencing these complications. The purpose of this study was to analyze the effect of polyethylene design on noise generation and anterior knee pain. METHODS We prospectively reviewed a cohort of patients who underwent primary TKA between 2014 and 2022 by a single surgeon using either a posterior-stabilized (PS) or ultracongruent (UC) polyethylene of the same implant design. The primary outcomes were measured through a noise generation questionnaire and the Knee Injury and Osteoarthritis Outcome Score-Patellofemoral score. RESULTS A total of 409 TKA procedures were included, 153 (37.4%) PS and 256 (62.6%) UC. No difference was noted in the Knee Injury and Osteoarthritis Outcome Score-Patellofemoral score between PS and UC designs (71.7 ± 26 versus 74.2 ± 23.2, P = 0.313). A higher percentage of patients in the PS cohort reported hearing (32.7% versus 22.3%, P = 0.020) or feeling noise (28.8 versus 20.3, P = 0.051) coming from their implant. No notable difference was observed in noise-related satisfaction rates. Independent risk factors of noise generation were age (OR, 0.96; P = 0.006) and PS polyethylene (OR, 1.61; P = 0.043). Noise generation was associated with decreased patient-reported outcome measure scores (P < 0.001). CONCLUSION While there was no difference in anterior knee pain between PS and UC polyethylene designs, PS inserts exhibit higher rates of noise generation compared with UC. Noise generation had comparable satisfaction but was associated with decreased patient-reported outcome measure scores.
Collapse
Affiliation(s)
- Juan D Lizcano
- From the Department of Orthopaedic Surgery, Rothman Orthopaedic Institute, Thomas Jefferson University Hospital, Philadelphia, PA (Lizcano, Molloy, Kohli, Yakkanti, and Tarabichi), and the Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY (Austin)
| | | | | | | | | | | |
Collapse
|
3
|
Favroul C, Batailler C, Naaim A, Foissey C, Kafelov M, Cheze L, Servien E, Lustig S. Cruciate-substituting and posterior-stabilised total knee arthroplasties had similar gait patterns in the short term. Knee Surg Sports Traumatol Arthrosc 2023; 31:5398-5406. [PMID: 37752347 DOI: 10.1007/s00167-023-07594-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
PURPOSE Surgeons want to achieve native kinematics in primary total knee arthroplasty (TKA). Cruciate-substituting (CS) implants could restore the knee kinematics more efficiently than posterior-stabilised (PS) TKA. This study aimed to compare gait patterns in patients with CS or PS TKA at 6 months. The hypothesis was that CS implants would demonstrate comparable gait parameters to PS implants at 6 months. METHODS In this prospective case-control study, 38 primary TKA without coronal laxity were divided into 2 groups: 19 cruciate-substituting (CS) and 19 posterior-stabilised (PS) implants. The type of prosthesis was determined according to the surgical period. Exclusion criteria were TKA revision, associated procedures and inability to walk on a treadmill. Gait analysis was conducted on a treadmill 6 months postoperatively for each patient with a knee assessment device (KneeKG®). Gait characteristics included analysis in three spatial dimensions (flexion-extension, abduction-adduction, internal-external rotation, anterior-posterior translation). Clinical outcomes (Knee Society Score and Forgotten Joint Score) were compared between both groups at 6 months postoperatively. RESULTS At 6 months, the gait analysis did not demonstrate any significant difference between CS and PS implants. The range and the maximum anteroposterior translation were similar in both groups (9.2 ± 6.5 mm in CS group vs. 8.1 ± 3 mm in PS group (n.s.); and - 5.2 ± 5 mm in CS group vs. - 6.3 ± 5.9 mm in PS group (n.s.), respectively). The internal/external rotation, the flexion, and the varus angle were similar between CS and PS implants. The KSS Knee score was higher at 6 months in the CS group than in the PS group (92.1 ± 5.6 vs. 84.8 ± 8.9 (p < 0.01)). CONCLUSION Cruciate-substituting and posterior-stabilised TKA had similar gait patterns at 6 months postoperatively, despite a non-equivalent posterior stabilisation system. CS prostheses were an interesting option for primary TKA for knee kinematics restoration without requiring a femoral box. LEVEL OF EVIDENCE Prospective, case-control study; Level II.
Collapse
Affiliation(s)
- Clément Favroul
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
| | - Cécile Batailler
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France.
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France.
| | - Alexandre Naaim
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - Constant Foissey
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
| | - Moussa Kafelov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
| | - Laurence Cheze
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
- LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| | - Sébastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon North University Hospital, 103 Grande Rue de la Croix-Rousse, 69004, Lyon, France
- Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, 69622, Lyon, France
| |
Collapse
|
4
|
Wenzel AN, Hasan SA, Chaudhry YP, Mekkawy KL, Oni JK, Khanuja HS. Ultracongruent Designs Compared to Posterior-Stabilized and Cruciate-Retaining Tibial Inserts - What Does the Evidence Tell Us? A Systematic Review and Meta-Analysis. J Arthroplasty 2023; 38:2739-2749.e7. [PMID: 37276953 DOI: 10.1016/j.arth.2023.05.064] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Revised: 05/23/2023] [Accepted: 05/25/2023] [Indexed: 06/07/2023] Open
Abstract
BACKGROUND Posterior-stabilized (PS) and cruciate-retaining (CR) have been the most common tibial designs used in total knee arthroplasty. Ultra-congruent (UC) inserts are becoming popular because they preserve bone without relying on the posterior cruciate ligament balance and integrity. Despite increasing use, there is no consensus on how UC inserts perform versus PS and CR designs. METHODS A comprehensive literature search of 5 online databases was performed for articles from January 2000 to July 2022 comparing the kinematic and clinical outcomes of PS or CR tibial inserts to UC inserts. There were nineteen studies included. There were 5 studies comparing UC to CR and 14 comparing UC to PS. Only one randomized controlled trial (RCT) was rated "good quality". RESULTS For CR studies, pooled analyses showed no difference in knee flexion (n = 3, P = .33) or Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores (n = 2, P = .58). For PS studies, meta-analyses showed better anteroposterior stability (n = 4, P < .001) and more femoral rollback (n = 2, P < .001) for PS but no difference in knee flexion (n = 9, P = .55) or medio-lateral stability (n = 2, P = .50). There was no difference with WOMAC (n = 5, P = .26), Knee Society Score (n = 3, P = .58), Knee Society Knee Score (n = 4, P = .76), or Knee Society Function Score (n = 5, P = .51). CONCLUSION Available data demonstrates there are no clinical differences between CR or PS and UC inserts in small short-term studies ending around 2 years after surgery. More importantly, high-quality research comparing all inserts is lacking, demonstrating a need for more uniform and longer-term studies beyond 5 years after surgery to justify increased UC usage.
Collapse
Affiliation(s)
- Alyssa N Wenzel
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Syed A Hasan
- Department of Orthopaedic Surgery, University of Central Florida/HCA Healthcare GME, Ocala, Florida
| | - Yash P Chaudhry
- Department of Orthopaedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania
| | - Kevin L Mekkawy
- Department of Orthopaedic Surgery, Holy Cross Orthopaedic Institute, Fort Lauderdale, Florida
| | - Julius K Oni
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Harpal S Khanuja
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, Maryland
| |
Collapse
|
5
|
Cozzarelli NF, Khan IA, Imam N, Klein GR, Levine H, Seidenstein A, Zaid MB, Lonner JH. Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty. Arthroplast Today 2023; 23:101216. [PMID: 37753221 PMCID: PMC10518686 DOI: 10.1016/j.artd.2023.101216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 08/01/2023] [Accepted: 08/18/2023] [Indexed: 09/28/2023] Open
Abstract
Background Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA. Methods A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed a survey consisting of 4 Likert scale questions related to prosthetic noise generation and Knee Injury and Osteoarthritis Score Joint Replacement and Forgotten Joint Score were assessed prospectively preoperatively and at a minimum of 1-year of clinical follow-up. Statistical analysis was done utilizing T-tests and chi-square tests, with statistical significance defined as a P-value < .05. Results One hundred sixty-two RA-TKAs and 320 C-TKAs with similar baseline characteristics and functions were included. There were no significant differences in hearing or feeling grinding, popping, clicking, or clunking (40.7% vs 38.1%; P = .647) between groups. Most RA-TKAs and C-TKAs were not dissatisfied regarding noise generation (70.4% vs 73.1%; P = .596). In both cohorts, patients who reported noise generation had lower average Forgotten Joint Scores (45.5 vs 66.1; P < .001) and lower postoperative Knee Injury and Osteoarthritis Score Joint Replacement scores (72.0 vs 81.4; P < .001) than those who did not experience noise generation. Conclusions While RA-TKA may facilitate soft tissue balancing, there were no differences in prosthetic noise generation between RA-TKA and C-TKA. However, those who experience implant-generated noise have lower functional outcome scores.
Collapse
Affiliation(s)
| | - Irfan A. Khan
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Nareena Imam
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Gregg R. Klein
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Harlan Levine
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Ari Seidenstein
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Musa B. Zaid
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| | - Jess H. Lonner
- Division of Adult Reconstruction, Rothman Orthopaedic Institute, Philadelphia, PA, USA
| |
Collapse
|
6
|
Tsai YL, Tsai SHL, Lin CH, Lin CR, Hu CC. The Effect of Congruent Tibial Inserts in Total Knee Arthroplasty: A Network Meta-Analysis of Randomized Controlled Trials. Life (Basel) 2023; 13:1942. [PMID: 37763345 PMCID: PMC10532924 DOI: 10.3390/life13091942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 09/07/2023] [Accepted: 09/18/2023] [Indexed: 09/29/2023] Open
Abstract
Objective: The aim of this study was to determine whether modern congruent tibial inserts are associated with superior outcomes in total knee arthroplasty (TKA). Background: Ultracongruent fixed-bearing (UCFB) and medial congruent fixed-bearing (MCFB) inserts have been known to be effective in total knee arthroplasty with patient satisfaction. Nonetheless, no supporting evidence to date exists to rank the clinical outcomes of these various congruent inserts in TKA compared with other important considerations in TKA including cruciate-retaining fixed-bearing (CRFB) and posterior-stabilized fixed-bearing (PSFB) inserts. Methods: We searched PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Scopus up to 15 May 2022. We selected studies involving an active comparison of UCFB or MCFB in TKAs. We performed a network meta-analysis (NMA) of randomized controlled trials (RCTs) and compared different congruent inserts. We ranked the clinical outcomes by SUCRA score with the estimate of the best treatment probability. Our primary outcomes were revision rates and radiolucent lines. Secondary outcomes were functional scores, including the range of motion (ROM), the Knee Society Score (KSS), the Oxford Knee Score (OKS), and WOMAC. Results: Eighteen RCTs with 1793 participants were analyzed. Our NMA ranked MCFB, CRFB, and UCFB with the lowest revision rates. CRFB and UCFB had the fewest radiolucent lines. UCFB had overall the best ROM. UCFB and MCFB had the best OKS score overall. Conclusions: The ranking probability for better clinical outcomes in congruent inserts demonstrated the superiority of congruent tibial inserts, including UCFB and MCFB. UCFB may be associated with better ROM and postoperative functional outcomes. However, integrating future RCTs for high-level evidence is necessary to confirm these findings.
Collapse
Affiliation(s)
- Yen-Lin Tsai
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
| | - Sung Huang Laurent Tsai
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Department of Orthopaedic Surgery, Chang Gung Memorial Hospital, Keelung Branch, Keelung 204, Taiwan
| | - Chia-Han Lin
- Department of Medicine, MacKay Medical College, New Taipei City 252, Taiwan
| | - Chun-Ru Lin
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
| | - Chih-Chien Hu
- Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- Bone and Joint Research Center, Chang Gung Memorial Hospital, Linkou Medical Center, No. 5, Fu-Hsin St. Kweishan County, Taoyuan 333, Taiwan
- College of Medicine, Chang Gung University, Taoyuan 333, Taiwan
| |
Collapse
|
7
|
Obana KK, Wong K, Shimoda BT, Rimm J, Stickley CD, Nakasone CK. Favorable outcomes of posterior cruciate-stabilized inserts over ultracongruent inserts in total knee arthroplasty. Arch Orthop Trauma Surg 2023; 143:5857-5865. [PMID: 36928502 DOI: 10.1007/s00402-023-04837-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 02/28/2023] [Indexed: 03/18/2023]
Abstract
OBJECTIVE Posterior cruciate-stabilized (PS) and ultracongruent (UC) inserts are used during total knee arthroplasty (TKA), but superiority in gaining postoperative knee flexion and functionality remains contested. Therefore, this study compared postoperative outcomes between PS and UC inserts. METHODS A retrospective review evaluated unilateral or bilateral TKAs with PS or UC inserts from August 2011 to March 2020. Nonparametric statistics were performed to evaluate differences in patient demographics, pre- and postknee flexion and Knee Society Knee (KSS-K) and Function Score (KSS-F). Univariate and multivariable regressions were performed to evaluate the influence on postoperative knee flexion ≥ 120°, presented as odds ratios (OR) and 95% confidence intervals (CI). RESULTS Patient demographics were not significantly different between the 577 PS and 399 UC knees evaluated. Postoperatively, a larger proportion of UC knees demonstrated knee flexion < 120° (36.0% vs. 18.6%, p < 0.001) and lower KSS-K (91.0 ± 8.7 vs. 91.6 ± 10.3, p < 0.001) and KSS-F (76.8 ± 21.6 vs. 79.9 ± 21.6, p = 0.007) than the PS group. The PS group had greater improvement in flexion angle (4.9° ± 14.9° vs. 1.0° ± 15.6°, p < 0.001) and KSS-F (27.3 ± 23.3 vs. 23.1 ± 25.3, p = 0.007) as compared to that of UC patients. Patients with preoperative flexion < 120° (OR 2.787, CI 2.066-3.761; p < 0.001), higher body mass index (OR 1.033, CI 1.006-1.061; p = 0.017) and UC insert (OR 2.461, CI 1.832-3.307; p < 0.001) were less likely to achieve flexion ≥ 120°. CONCLUSION Favorable clinical and functional outcomes were noted in the PS group as compared to UC inserts in TKA. The greater improvement in overall knee flexion may suggest the PS insert may be especially appropriate for patients with lower preoperative range of motion. LEVEL OF EVIDENCE III, retrospective comparative study.
Collapse
Affiliation(s)
- Kyle K Obana
- John A. Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
| | - Krystin Wong
- John A. Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
- Straub Medical Center, Bone and Joint Center, 888 South King Street, Honolulu, HI, 96818, USA
| | - Brent T Shimoda
- Straub Medical Center, Bone and Joint Center, 888 South King Street, Honolulu, HI, 96818, USA
| | - Julian Rimm
- John A. Burns School of Medicine, 651 Ilalo Street, Honolulu, HI, 96813, USA
| | - Christopher D Stickley
- Department of Anatomy, Biochemistry, and Physiology, University of Hawai'i, John A. Burns School of Medicine, 1356 Lusitana Street, Honolulu, HI, 96813, USA
| | - Cass K Nakasone
- Straub Medical Center, Bone and Joint Center, 888 South King Street, Honolulu, HI, 96818, USA.
- Department of Surgery, University of Hawai'i, John A. Burns School of Medicine, 1356 Lusitana Street, Honolulu, HI, 96813, USA.
| |
Collapse
|
8
|
Movassaghi K, Patel A, Ghulam-Jelani Z, Levine BR. Modern Total Knee Arthroplasty Bearing Designs and the Role of the Posterior Cruciate Ligament. Arthroplast Today 2023; 21:101130. [PMID: 37151403 PMCID: PMC10160699 DOI: 10.1016/j.artd.2023.101130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/04/2023] [Accepted: 03/08/2023] [Indexed: 05/09/2023] Open
Abstract
The role of the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) surgery continues to be a source of debate among the adult reconstruction community. In native knee flexion, the PCL is comprised of an anterolateral and posteromedial bundle that work together to limit posterior tibial translation and allow adequate femoral rollback for deep flexion. In the arthritic knee, the PCL can often become dysfunctional and attenuated, which led to the development of posterior stabilized (PS) TKA bearing options. PS TKAs implement a cam-post construct to functionally replace a resected PCL. While PS designs may facilitate balancing knees with significant deformity, they are associated with complications such as postfracture, increased wear, and patellar clunk/crepitus. In recent years, newer designs have been popularized with greater degrees of congruency and incorporation of medial and lateral pivoting to better recreate native knee kinematics. The American Joint Registry has confirmed the recent predilection for ultra-congruent and cruciate-retaining TKA inserts over PS TKAs during the last decade. Studies have failed to identify an overall clinical superiority between the cruciate substituting and sacrificing designs. The literature has also failed to identify clinical consequences from PCL resection with modern, more conforming TKA designs. In this article, we review modern PCL sacrificing designs and discuss the impact of each on the kinematics after TKA. We also will delineate the role of the PCL in modern TKA in the hopes to better understand the recent surge in sacrificing but not substituting knee implants.
Collapse
Affiliation(s)
- Kamran Movassaghi
- Department of Orthopaedic Surgery, University of California, San Francisco Fresno, Fresno, CA, USA
- Corresponding author. University of California, San Francisco Fresno, 2823 Fresno Street, Fresno, CA 93721, USA. Tel.: +1 818 640 5244.
| | - Arpan Patel
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Zohal Ghulam-Jelani
- Department of Orthopaedic Surgery, University of California, San Francisco Fresno, Fresno, CA, USA
| | - Brett R. Levine
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
9
|
Sohn S, Koh IJ, Kim MS, Choi KY, Lim DS, In Y. Mobile-Bearing has no Benefit Over Fixed-Bearing Total Knee Arthroplasty in Joint Awareness and Crepitus: A Randomized Controlled Trial. J Arthroplasty 2023; 38:78-84. [PMID: 35934188 DOI: 10.1016/j.arth.2022.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 07/26/2022] [Accepted: 07/28/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Given higher component conformity, rotational availability of polyethylene insert, and more physiologic patellofemoral tracking, mobile-bearing (MB) total knee arthroplasty (TKA) is supposed to offer advantages in joint perception and crepitus. The purpose of this study was to investigate whether MB TKA offers superior outcomes over fixed-bearing (FB) TKA in terms of joint awareness and crepitus. METHODS This prospective, randomized, controlled trial included 49 FB and 49 MB TKAs that shared the same posterior-stabilized femoral component. Primary outcomes included joint awareness assessed with the Forgotten Joint Score and crepitus graded according to severity and sound at 3 years postoperatively. Secondary outcomes were the range of motion, the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index, component position, and joint line level on radiographs. RESULTS The Forgotten Joint Score showed no significant difference between the FB (67 points; range, 0-100) and MB groups (63 points; range, 13-100) (P = .440). For crepitus, no significant differences were found in the overall incidence rate (FB group, 18%; MB group, 12%; P = .386) and grade (grade 1, 6 versus 5; grade 2, 2 versus 1; grade 3, 1 versus 0, respectively). There were no significant differences in range of motion, Knee Society Score, and Western Ontario and McMaster Universities Osteoarthritis Index, as well as radiographic outcomes between the two groups (all, P > .05). CONCLUSION MB TKA offers no benefits in terms of joint awareness and crepitus compared with FB TKA at mean 3 years postoperatively. The theoretical advantages of MB TKA have yet to be demonstrated in practice, leaving the selection of bearing type to the surgeon's judgment. LEVEL OF EVIDENCE Level II.
Collapse
Affiliation(s)
- Sueen Sohn
- Department of Orthopaedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Republic of Korea
| | - In Jun Koh
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Man Soo Kim
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Keun Young Choi
- Department of Orthopaedic Surgery, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Da Sol Lim
- Department of Orthopaedic Surgery, Inje University Sanggye Paik Hospital, College of Medicine, Inje University, Seoul, Republic of Korea
| | - Yong In
- Department of Orthopaedic Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
10
|
A prospective comparison of total knee arthroplasty using ultra-congruent, condylar-stabilizing, and posterior-stabilized devices implanted with kinematic alignment: better 2-year outcomes with ultra-congruent. Knee Surg Sports Traumatol Arthrosc 2023; 31:1026-1033. [PMID: 36318322 PMCID: PMC9957877 DOI: 10.1007/s00167-022-07206-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 10/19/2022] [Indexed: 02/14/2023]
Abstract
PURPOSE This study compared the 5-year results of posterior cruciate ligament (PCL)-sacrificing total knee arthroplasty (TKA) with either a post and cam posterior-stabilized (PS) device, a dished, congruent condylar-stabilizing (CS) device, or a deep-dished ultra-congruent (UC) device. The hypothesis was that the clinical and radiographic outcomes would be equivalent. CS and PS participants were part of a prospective, randomized trial, and UC participants were part of a separate prospective, non-randomized protocol that was otherwise identical. A kinematic alignment surgical technique was utilized. METHODS Participants were assessed preoperatively, and postoperatively at 6 weeks, 6 months, and annually for 5 years by Knee Society Score (KSS), SF-36 v2, Lower Extremity Activity Scale (LEAS), and physical and radiographic evaluation. There were 116 CS/PS participants and 69 UC participants who participated in the study. RESULTS Tourniquet (P = .02) and operative (P = .01) times for the CS and UC groups were significantly shorter than the PS group. KSS Function scores were better for the UC group than the CS and PS groups at 6 months (P = .04) and 1 year (P = .03), and better in the UC group vs. CS at 2 years (P = .04). The KSS Pain-only score was also better in the UC compared to PS at 6 months (P = .04). There were no significant differences for the KSS Pain/Motion scores, flexion, SF-36, and LEAS scores at any time. CONCLUSION These data confirm the hypothesis that there are no clinically meaningful significant differences in outcomes between the three groups at a 5-year minimum follow-up, though there is a trend toward less pain and better function at earlier visits in the UC group. LEVEL OF EVIDENCE II.
Collapse
|
11
|
Chen Z, Bains SS, Hameed D, Dubin JA, Stern JM, Mont MA. Robust Randomized Controlled Data Is Lacking in Total Joint Arthroplasty. J Knee Surg 2022; 35:1533-1539. [PMID: 36427523 DOI: 10.1055/s-0042-1758550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Randomized controlled trials (RCTs)are regarded as highest level of scientific evidence. There is belief that while prospective randomized control trials (PRCTs) are the gold standard for evaluating efficacy of interventions, there are very few conducted on lower extremity joint arthroplasty. However, there was a more than adequate amount (n=197) of published RCTs in knee arthroplasty during the 2021 calendar year. Therefore, we studied RCTs on knee arthroplasties for 2021 and assessed them for overall study topic reasons (i.e., devices as well as prostheses, rehabilitation, pain control, blood loss [tranexamic acid], and other), which were then subcategorized by: (1) country of origin; (2) sample size; and (3)whether or not they were follow-up studies. After this, we specifically focused on the studies (n=26) concerning devices or prostheses. METHODS A search of PubMed on "knee arthroplasty" specifying "RCT" using their search function and dates between January 1, 2021 to December 24, 2021 resulted in the analyzed reports. A total of 17.3% reports analyzed rehabilitation methods while 28.4% studied pain control. A total of 20.3% examined blood loss topics and 20.8% investigated other topics. RESULTS We found that 26 studies (13.2%) involved prosthetic design and implantation. Overall, only 15% knee arthroplasty RCTs were conducted in the United States, the mean total final sample size was 133±146 patients, and 7% were follow-up studies. None of the prostheses studies were performed in the United States, and the mean total final sample size of all of these studies was 86±54 patients, and 23% were follow-up studies. Total knee arthroplasty prospective RCTs were not performed in the United States. CONCLUSION The authors believe that other study designs, such as database or registry analyses, are also appropriate in this rapidly advancing field of joint arthroplasty for the continuing evaluation and approval of new prostheses and techniques, while we await more PRCTs in our field.
Collapse
Affiliation(s)
- Zhongming Chen
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| | - Sandeep S Bains
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| | - Daniel Hameed
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| | - Jeremy A Dubin
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| | - Jonathan M Stern
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| | - Michael A Mont
- Department of Orthopedic Surgery, Sinai Hospital of Baltimore, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland
| |
Collapse
|
12
|
Mulpur P, Masilamani A, Prakash M, Annapareddy A, Hippalgaonkar K, Reddy A. Comparison of patient reported outcomes after robotic versus manual total knee arthroplasty in the same patient undergoing staged bilateral knee arthroplasty. J Orthop 2022; 34:111-115. [PMID: 36060731 PMCID: PMC9428725 DOI: 10.1016/j.jor.2022.08.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 08/10/2022] [Accepted: 08/11/2022] [Indexed: 11/25/2022] Open
Abstract
Background Robotic-assisted total knee arthroplasty (RATKA) has been proven to improve accuracy of component positioning and reducing alignment target outliers. However, the clinical benefit of robotics is often debated. Recent studies have shown reduced pain and faster recovery in the immediate post-operative period and may be associated with improved PROMs and satisfaction. The aim of this study was to assess PROMs and satisfaction in a unique patient population undergoing bilateral staged TKA to compare manual (MTKA) and RATKA in the same patient. Methods 55 patients underwent bilateral staged TKA, performed by a single surgeon at a single institute. Patients who underwent TKA for the first knee with manual technique and RATKA for the second side, were eligible for inclusion in the study. Primary outcome assessed was the Oxford Knee Score and secondary outcomes included the Forgotten Joint Score (FJS), patient satisfaction, mean duration for independent ambulation after TKA, and patient perspectives on recovery evaluated with a questionnaire. Results Both RATKA and MTKA were associated with comparable PROMs. Though RATKA was associated with improved joint perception (Mean FJS after MTKA surgery was 70.3 (SD = 10.66) and significantly lower than the mean FJS after RATKA (73, SD = 10.95, p-value < 0.01), but the difference was not clinically relevant. A higher proportion of patients were more likely to be very satisfied or satisfied after RATKA. A significant proportion of patients felt the knee operated with RATKA was less painful and felt more natural compared to MTKA at final follow-up (p < 0.01). Majority of patients would undergo RATKA again and recommend robotic-TKA to others. Conclusion Robotic-assisted surgery was associated with improved patient satisfaction, faster independent ambulation compared to manual techniques. PROMs however, were comparable without clinically significant differences. Patients preferred robotic-assisted surgery, with a significantly higher proportion perceiving knee operated by RATKA felt more natural.
Collapse
Affiliation(s)
- Praharsha Mulpur
- Sunshine Bone and Joint Institute, Sunshine Hospitals, Hyderabad, India
| | | | - Mrinal Prakash
- Sunshine Bone and Joint Institute, Sunshine Hospitals, Hyderabad, India
| | | | | | - A.V.Gurava Reddy
- Sunshine Bone and Joint Institute, Sunshine Hospitals, Hyderabad, India
| |
Collapse
|
13
|
Hinarejos P, Leal-Blanquet J, Fraile-Suari A, Sánchez-Soler J, Torres-Claramunt R, Monllau JC. Increased posterior translation but similar clinical outcomes using ultracongruent instead of posterior stabilized total knee arthroplasties in a prospective randomized trial. Knee Surg Sports Traumatol Arthrosc 2022; 30:3041-3048. [PMID: 34436635 DOI: 10.1007/s00167-021-06710-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/14/2021] [Indexed: 12/22/2022]
Abstract
PURPOSE The aim of this study was to compare the posterior tibial translation after ultracongruent (UC) and posterior-stabilized (PS) total knee arthroplasty (TKA) with two different UC with different heights in the anterior lip, and two different PS designs. This study also aimed to compare the range of motion (ROM) and outcomes scores after the use of these TKA models. It was hypothesised less posterior tibial translation after PS than after UC TKA, and less posterior tibial translation with a higher anterior lip in the UC insert than with a lower one. METHODS It was designed as a prospective randomized study of a group of 120 patients operated with a cemented TKA. To clarify the main purpose of the study, four groups were analysed using different polyethylene designs: Triathlon PS insert in group one, Triathlon UC insert in group two, U2 PS insert in group three and U2 UC insert in group four. One year after surgery, a forced posterior drawer with a Telos Stress applying 15 kg of force posteriorly on the proximal tibia at 90° of knee flexion was analysed in the lateral radiograph. Limb alignment, tibial posterior slope and posterior condylar offset were also studied. RESULTS 30 patients were included in each group. The average age was 73 years. There were 72.2% female and 27.8% male patients. There were no significant differences in any demographic or radiographic studied variables, preoperative range of motion (ROM) or preoperative Knee Society Scores (KSS) among the different groups. One year after surgery, the average postoperative ROM and the postoperative KSS Knee and KSS Function scores improved in respect of the preoperative values in all the groups. There were no significant differences in the postoperative outcome scores among the different groups (p = n.s.). Postoperative alignment of the limb, tibial posterior slope and posterior condylar offset were similar in the 4 study groups (p = n.s.). The postoperative posterior tibial translation was different between groups: the PS groups (groups 1 and 3) showed significant inferior values (p < 0.001) in respect of the UC groups (groups 2 and 4). There were no differences between both groups of PS models, but there was a significant increase in the posterior tibial translation of the Triathlon UC insert (11.2 mm SD 3.2) in respect of the U2 UC insert (6.1 mm SD 4.5) (p = 0.004). CONCLUSIONS UC inserts restrict the posterior tibial translation after TKA less than PS inserts, but a design with a high anterior lip in the polyethylene UC insert can better control the posterior tibial translation than an insert with a small anterior lip. LEVEL OF EVIDENCE Level I. Randomised controlled trial.
Collapse
Affiliation(s)
- Pedro Hinarejos
- Department of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya 12, 08024, Barcelona, Spain. .,Universitat Autonoma de Barcelona, Barcelona, Spain.
| | - Joan Leal-Blanquet
- Department of Orthopedic Surgery, Hospital d'Igualada, Consorci Sanitari de L'Anoia, Av. Catalunya, 11, 08700, Igualada Barcelona, Spain
| | - Anna Fraile-Suari
- Department of Orthopedic Surgery, Hospital Sant Camil, Ronda Sant Camil S/N, 08810, Sant Pere de Ribes, Barcelona, Spain
| | - Juan Sánchez-Soler
- Department of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya 12, 08024, Barcelona, Spain
| | - Raul Torres-Claramunt
- Department of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya 12, 08024, Barcelona, Spain
| | - Juan Carlos Monllau
- Department of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya 12, 08024, Barcelona, Spain.,Universitat Autonoma de Barcelona, Barcelona, Spain
| |
Collapse
|
14
|
In vivo kinematic comparison between an ultra-congruent and a posterior-stabilized total knee arthroplasty design by RSA. Knee Surg Sports Traumatol Arthrosc 2022; 30:2753-2758. [PMID: 34117894 DOI: 10.1007/s00167-021-06629-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 06/07/2021] [Indexed: 10/21/2022]
Abstract
PURPOSE The aim of the present study was to compare the in vivo under weight-bearing kinematic behavior of a posterior-stabilized (PS) and an ultra-congruent (UC) total knee arthroplasty (TKA) model during a sit-to-stand motor task, a common activity of daily life. METHODS A cohort of 16 randomly selected patients (8 PS Persona Zimmer, 8 UC Persona Zimmer) was evaluated through dynamic radiostereometric analysis (RSA) at a minimum of 9 months after TKA, during the execution of a sit-to-stand. The anteroposterior (AP) translation of the femoral component and the AP translation of the low point of medial and lateral femoral compartments were compared through Student's t test (p < 0.05). RESULTS A significantly greater anterior translation of the femoral component was found for the PS group compared to the UC group. The flexion interval where statistical significance was found was between 30° and 0° (p = 0.017). Both groups showed a significantly greater anterior translation of the low point of the lateral compartment with respect to the medial one (PS: p = 0.012, UC: p = 0.018). This was consistent with a medial-pivot pattern. Furthermore, a significantly greater anterior translation of the medial compartment was found in the PS group compared to the UC group (p = 0.001). The same pattern was observed for the lateral compartment (p = 0.006). CONCLUSIONS The TKA designs evaluated in the present study showed comparable in-vivo kinematics with regards to medial pivot pattern but differences in absolute AP translation. Specifically, the UC design showed greater AP stability than the PS design. This finding could be positive in terms of implant stability, but negative in terms of premature polyethylene wear and thus implant failure. This remains to be verified in studies with a larger sample size and longer follow-up. LEVEL OF EVIDENCE IV.
Collapse
|
15
|
Krumme J, Kankaria R, Vallem M, Cyrus J, Sculco P, Golladay G, Kalore N. Comparative Analysis of Contemporary Fixed Tibial Inserts: A Systematic Review and Network Meta-analysis of Randomized Controlled Trials. Orthop Rev (Pavia) 2022; 14:35502. [PMID: 35769654 PMCID: PMC9235430 DOI: 10.52965/001c.35502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 05/03/2022] [Indexed: 11/06/2022] Open
Abstract
Background Multiple options are available for the tibial insert in total knee arthroplasty (TKA). A systematic review (SR) and network meta-analysis (NMA) to compare available randomized controlled trials (RCTs) could assist with decision making. We aim to show that designs with increased conformity may improve function and satisfaction without an increase in complications though posterior stabilized (PS) inserts will likely have more flexion. Methods A search of MEDLINE, EMBASE, and the Cochrane Library was performed. Studies were limited to RCTs evaluating cruciate retaining (CR), PS, anterior stabilized (AS), medial pivot (MP), bicruciate retaining (BR), and bicruciate stabilizing (BCS) inserts. Mean differences (MD) were used for patient reported outcome measures (PROMs) and odds ratios (OR) for reoperation rates and MUA. A systematic review was performed for satisfaction. Results 27 trials were identified. The NMA showed no difference from a statistical or clinical standpoint for PROMs evaluated. There was a statistical difference for increased flexion for PS knees (3 degrees p 0.04). There were no differences in the MUA or reoperation rates. There was insufficient information to determine if a specific insert improved satisfaction. Discussion The results of this NMA show no statistical or clinical difference in PROMs. There was higher flexion for PS knees though the amount was not clinically significant. There was insufficient data for conclusions on patient satisfaction. Therefore, the surgeon should evaluate the clinical situation to determine the best insert rather than choose and insert based on functional scores, patient satisfaction, or complication rates.
Collapse
Affiliation(s)
- John Krumme
- Orthopaedic Surgery, University of Missouri Kansas City
| | | | - Madana Vallem
- Orthopaedic Surgery, Virginia Commonwealth university
| | - John Cyrus
- Orthopaedic Surgery, Virginia Commonwealth University
| | - Peter Sculco
- Orthopaedic Surgery, Hospital for Special Surgery
| | | | - Niraj Kalore
- Orthopaedic Surgery, Virginia Commonwealth University
| |
Collapse
|
16
|
Press-Fit Dual-Pivot Total Knee Arthroplasty: Early Results With a Minimum 2-Year Follow-Up. J Arthroplasty 2022; 37:S238-S244. [PMID: 35197199 DOI: 10.1016/j.arth.2022.01.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/24/2021] [Accepted: 01/15/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Ultracongruent (UC) tibial bearings are being used with increasing frequency in the United States. Evidence suggests that the use of certain UC bearings may lead to improved patient satisfaction when compared with using conventional inserts. However, little is known as to what effect the use of UC tibial inserts has on bone ingrowth in uncemented total knee arthroplasty (TKA). The purpose of this study was to determine the early clinical and radiographic results of TKA using a press-fit dual-pivot design. METHODS Between 2017 and 2019, a consecutive series of 232 TKAs were implanted using a press-fit tibial and femoral component and a UC dual-pivot tibial insert. Sixty-two percent of patients were male. The average age was 56 years. Patients were followed for a minimum of 2 years (range, 24-42 months) using KOOS-JR and Knee Society clinical and radiographic evaluation. RESULTS No patient had more than mild knee stiffness at the final follow-up. Two patients reported moderate knee pain with stair climbing. All other patients reported either mild or no pain with activity. Knee Society pain scores averaged 42 points. Flexion averaged 118 degrees. Three knees (1.3%) were revised (one each for flexion instability, tibial plateau fracture, and suspected femoral component loosening). No other cases of femoral or tibial loosening were identified. CONCLUSION Although the success of uncemented TKA is determined by a variety of factors, the use of this dual-pivot knee design did not appear to influence tibial or femoral component fixation at early follow-up, yielding acceptable clinical and radiographic outcomes.
Collapse
|
17
|
Shatrov J, Sappey-Marinier E, Kafelov M, Gunst S, Batailler C, Servien E, Lustig S. Similar outcomes including maximum knee flexion between mobile bearing condylar-stabilised and fixed bearing posterior-stabilised prosthesis: a case control study. J Exp Orthop 2022; 9:17. [PMID: 35169966 PMCID: PMC8847635 DOI: 10.1186/s40634-022-00456-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Accepted: 02/11/2022] [Indexed: 11/12/2022] Open
Abstract
Purpose Prosthesis design influences stability in total knee arthroplasty and may affect maximum knee flexion. Posterior-stabilised (PS) and condylar-stabilised (CS) designed prosthesis do not require a posterior-cruciate ligament to provide stability. The aim of the current study was to compare the range of motion (ROM) and clinical outcomes of patients undergoing cemented total knee arthroplasty (TKA) using either a PS or CS design prosthesis. Methods A total of 167 consecutive primary TKAs with a CS bearing (mobile deep-dish polyethylene) were retrospectively identified and compared to 332 primary TKA with a PS constraint, with similar design components from the same manufacturer. Passive ROM was assessed at last follow-up with use of a handheld goniometer. Clinical scores were assessed using Patient-Reported Outcome Measures (PROMs); International Knee Society (IKS) knee and function scores and satisfaction score. Radiographic assessment was performed pre and post operatively consisting of mechanical femorotibial angle (mFTA), femoral and tibial mechanical angles measured medially (FMA and TMA, respectively) on long leg radiographs, tibial slope and patella height as measured by the Blackburne-Peel index (BPI). Results Both groups had a mean follow-up of 3 years (range 2–3.7 years). Mean post-operative maximum knee flexion was 117° ± 4.9° in the PS group and 119° ± 5.2° in the CS group (p = 0.29). Postoperative IKS scores were significantly improved in both groups compared to preoperative scores (p < 0.01). The mean IKS score in the PS group was 170.9 ± 24.1 compared to 170.3 ± 22.5 in the CS group (p = 0.3). Both groups had similar radiographic outcomes as determined by coronal and sagittal alignment, tibial slope and posterior condylar offset ratio measurements. When considering the size of tibial slope change and posterior-condylar offset ratio, there was no differences between groups (p = 0.4 and 0.59 respectively). The PS group had more interventions for post-operative stiffness (arthrolysis or manipulation under anaesthesia) 8 (2.7%) compared to 1 (0.6%) in the CS group (p = 0.17). Conclusion Condylar-stabilised TKA have similar patient outcomes and ROM at a mean follow-up of 3 years compared to PS TKA. Highly congruent inserts could be used without compromising results in TKA at short term. Level of evidence Level IV, retrospective case control study.
Collapse
Affiliation(s)
- Jobe Shatrov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Sydney Orthopaedic Research Institute, Chatswood, Sydney, Australia.,University of Notre Dame Australia, Sydney, Australia.,Hornsby and Ku-Ring Hospital, Sydney, Australia
| | - Elliot Sappey-Marinier
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France. .,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France.
| | - Moussa Kafelov
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Stanislas Gunst
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France
| | - Cécile Batailler
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| | - Elvire Servien
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,LIBM - EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University, Lyon, France
| | - Sébastien Lustig
- Orthopaedics Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital, Lyon, France.,Univ Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406, F69622, Lyon, France
| |
Collapse
|
18
|
Villa JM, Pannu TS, Higuera-Rueda CA. What's New in Adult Reconstructive Knee Surgery. J Bone Joint Surg Am 2022; 104:97-106. [PMID: 34780387 DOI: 10.2106/jbjs.21.01080] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Jesus M Villa
- Levitetz Department of Orthopaedic Surgery, Cleveland Clinic Florida, Weston, Florida
| | | | | |
Collapse
|
19
|
Lützner J, Beyer F, Lützner C, Riedel R, Tille E. Ultracongruent insert design is a safe alternative to posterior cruciate-substituting total knee arthroplasty: 5-year results of a randomized controlled trial. Knee Surg Sports Traumatol Arthrosc 2022; 30:3000-3006. [PMID: 33842984 PMCID: PMC9418092 DOI: 10.1007/s00167-021-06545-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 03/18/2021] [Indexed: 01/06/2023]
Abstract
PURPOSE If substitution of the posterior cruciate ligament in total knee arthroplasty is necessary, there are two options available: posterior stabilized (PS) design with a post-cam mechanism or anterior-lipped ultracongruent (UC) inserts. UC inserts have the advantage that no femoral box is necessary and a standard femoral component can be used. The aim of this study was to compare the range of motion (ROM) and patient-reported outcome (PRO) after UC and PS fixed-bearing TKA. Better ROM in PS TKA and no difference in PRO between both designs was hypothesized. METHODS A randomized controlled trial with 127 patients receiving a fixed-bearing UC or PS design of the same knee system was performed. Nine patients died and there were four revision surgeries. 107 patients completed the 5-year follow-up. Patient-reported outcome was assessed. Patellofemoral problems were evaluated using selected applicable questions of the Oxford Knee Score (getting up from a table, kneeling, climbing stairs). RESULTS Surgical time was 10 min shorter in the UC group (p < 0.001). After 5 years, both groups demonstrated good knee function and health-related quality of life without significant differences between the groups. Both groups demonstrated a high satisfaction score and the majority of patients would undergo this surgery again. Patellofemoral problems were recognized more frequently in the PS group (p = 0.025). CONCLUSION Both designs demonstrated similar good results after 5 years. Stabilization with an anterior-lipped UC insert can be considered a safe alternative to the well-established PS design if cruciate substitution is necessary.
Collapse
Affiliation(s)
- Jörg Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Germany.
| | - Franziska Beyer
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307 Dresden, Germany
| | - Cornelia Lützner
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307 Dresden, Germany
| | - Roman Riedel
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307 Dresden, Germany
| | - Eric Tille
- University Center of Orthopaedic, Trauma and Plastic Surgery, University Hospital Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307 Dresden, Germany
| |
Collapse
|
20
|
Lin TL, Tsai CH, Fong YC, Shie MY, Chen HY, Chen YW. Cruciate-Retaining vs Posterior-Stabilized Antibiotic Cement Articulating Spacers for Two-Stage Revision of Prosthetic Knee Infection: A Retrospective Cohort Study. J Arthroplasty 2021; 36:3750-3759.e2. [PMID: 34284935 DOI: 10.1016/j.arth.2021.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2021] [Revised: 05/17/2021] [Accepted: 06/21/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Antibiotic cement articulating spacers are recommended during 2-stage revision for prosthetic knee infection because of increased range of motion (ROM) and improved function; however, spacer mechanical complications have been reported. We aimed to determine the association between different constraints of articulating spacers and the rate of complications and infection eradication, functional outcomes, and ROM. METHODS A retrospective study of prosthetic knee infection using cruciate-retaining (CR) or posterior-stabilized (PS) spacers was conducted between 2011 and 2018. The rate of spacer mechanical complications, infection eradication after reimplantation and reoperation, Hospital of Special Surgery (HSS) knee score, and ROM during the interim stage were analyzed. All patients were regularly followed up for 2 years. RESULTS One hundred forty-one patients were included, with 66 CR and 75 PS spacers. Overall mechanical complication rate was lower in PS (9.3%) than in CR spacers (45.5%) (P < .001), especially in joint dislocation (1.3% vs 30.3%, respectively, P < .001). Overall reoperation rate was lower in PS (16.0%) than in CR spacers (36.4%) (P < .001), especially for mechanical complications (1.3% vs 24.2%, respectively, P < .001). HSS knee score was higher in PS (72.3) than in CR spacers (63.8) (P < .001). ROM was greater in PS (90.3°) than in CR spacers (80.6°) (P = .005), especially at maximum flexion (102.4° vs 89.6°, respectively, P = .003). Infection eradication was comparable between the spacers. CONCLUSION Both spacers can control infection; however, PS spacers had a lower rate of mechanical complications and reoperation, better HSS knee scores, and greater ROM than CR spacers.
Collapse
Affiliation(s)
- Tsung-Li Lin
- Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan; Department of Sports Medicine, College of Health Care, China Medical University, Taichung, Taiwan; Graduate Institute of Biomedical Sciences, China Medical University, Taichung, Taiwan
| | - Chun-Hao Tsai
- Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan; Department of Sports Medicine, College of Health Care, China Medical University, Taichung, Taiwan
| | - Yi-Chin Fong
- Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan; Department of Sports Medicine, College of Health Care, China Medical University, Taichung, Taiwan; Department of Orthopedics, China Medical University Beigang Hospital, Yunlin, Taiwan
| | - Ming-You Shie
- X-Dimension Center for Medical Research and Translation, China Medical University Hospital, Taichung, Taiwan; School of Dentistry, China Medical University, Taichung, Taiwan; Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan
| | - Hui-Yi Chen
- Department of Radiology, China Medical University Hospital, Taichung, Taiwan
| | - Yi-Wen Chen
- Graduate Institute of Biomedical Sciences, China Medical University, Taichung, Taiwan; X-Dimension Center for Medical Research and Translation, China Medical University Hospital, Taichung, Taiwan; Department of Bioinformatics and Medical Engineering, Asia University, Taichung, Taiwan
| |
Collapse
|
21
|
Comparison of Functional Outcomes, Femoral Rollback and Sagittal Stability of Anterior-Stabilized Versus Posterior-Stabilized Total Knee Arthroplasty: A Systematic Review and Meta-analysis of Randomized Controlled Trials. Indian J Orthop 2021; 55:1076-1086. [PMID: 34824707 PMCID: PMC8586404 DOI: 10.1007/s43465-021-00494-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 08/15/2021] [Indexed: 02/04/2023]
Abstract
PURPOSE Total knee arthroplasty (TKA) has improved leaps and bounds in terms of design to improve clinical outcomes and achieve better rehabilitation of the patients. Ultra-congruent inserts (UC) were designed to replace the need for posterior stabilized (PS) implants. The purpose of this review was to evaluate clinical outcomes, femoral rollback, functional scores, range of motion, sagittal laxity, complication rates, and isokinetic performance between UC and PS TKA among RCTs. METHODS Electronic databases such as PubMed, Scopus, opengrey, and Cochrane were searched from date of inception up to mid-April 2021, and meta-analysis was performed following PRISMA guidelines. This study analyzed outcomes, femoral rollback, tibial sagittal laxity and isokinetic performance. RESULTS Ten RCTs identified 852 knees, of which 420 underwent UC TKAs and 432 underwent PS TKA. Compared to UC TKA, a significantly better sagittal stability (p = 0.17) and femoral rollback (p < 0.00001) in PS TKAs was noted, although no statistically significant difference was found in the assessment of the range of motion (p = 0.19) and functional scores. Both the groups had similar isokinetic performance with extensor torque (p = 0.97) and flexor torque (p = 0.37). CONCLUSIONS We conclude with the current meta-analysis that there are no added benefits for UC over PS inserts and these inserts have a higher sagittal laxity and less femoral roll back in cruciate sacrificing UC knee. But since there are no long-term wear data, UC inserts with CS technique should be used cautiously and may be used only when the PCL cannot be balanced adequately. There is no evidence or only a few to support the superiority of the AS TKA in terms of clinical outcomes or isokinetic performance or femoral external rotation over PS TKA. LEVEL OF EVIDENCE Level I, Systematic review and meta-analysis of RCTs.
Collapse
|