1
|
DeBernardis D, Donnelly D, Bahel A, Favorito P. Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: midterm results of an all-polyethylene, posteriorly augmented, stepped glenoid component. J Shoulder Elbow Surg 2024:S1058-2746(24)00317-3. [PMID: 38719072 DOI: 10.1016/j.jse.2024.03.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 03/03/2024] [Accepted: 03/11/2024] [Indexed: 07/25/2024]
Abstract
BACKGROUND The purpose of this study is to report the minimum 5-year clinical and radiographic outcomes of patients undergoing anatomic total shoulder arthroplasty (aTSA) with a posteriorly augmented glenoid component. METHODS Thirty-five shoulders with minimum 5-year follow-up underwent aTSA using a posteriorly augmented glenoid component for the treatment of glenohumeral osteoarthritis with posterior glenoid bone loss. Clinical outcomes included range of motion, visual analog scale (VAS) for pain, and patient-reported outcomes scores. Radiographs and computed tomography scans were obtained to assess glenoid morphology, retroversion, and central peg osseous integration via Wirth score, Lazarus scores, and Yian scores. Postoperative outcomes were measured at minimum 2- and 5-year follow-up. Kaplan-Meier survival analysis was calculated. RESULTS Two patients experienced prosthetic instability requiring revision, leaving 33 shoulders with an average follow-up of 6.6 years. Average preoperative glenoid retroversion was 21.6°. A significant improvement in pain, range of motion, and patient-reported outcomes score was noted at minimum 2- and 5-year follow-up. In addition, VAS pain, American Shoulder and Elbow Surgeons, and Quick Disabilities of the Arm, Shoulder, and Hand scores improved between minimum 2- and 5-year follow-up. The average Lazarus and Yian scores at final follow-up were 0.73 and 2.6, respectively. There was an increase in Lazarus score and a decrease in Wirth score between 2- and 5-year follow-up. A significant correlation was identified between VAS pain scores and both Lazarus and Wirth scores. Survivorship free from revision was 92% at 8.8 years postoperatively. CONCLUSIONS Midterm results of aTSA with a posteriorly augmented, stepped glenoid component demonstrate sustained improvements in clinical outcomes with low rates of radiographic loosening. Continued improvement in pain and function, as well as a minor progression of radiographic osteolysis, may be expected between 2- and 5-year follow-up. In addition, the severity of radiographic loosening correlates with subjective pain levels.
Collapse
Affiliation(s)
- Dennis DeBernardis
- Division of Shoulder and Elbow Surgery, The Rothman Orthopaedic Institute, Jersey City, NJ, USA.
| | - David Donnelly
- Division of Shoulder and Elbow Surgery, The Christ Hospital, Cincinnati, OH, USA
| | - Aditya Bahel
- Professional Radiology Inc., Cincinnati, OH, USA
| | - Paul Favorito
- Division of Shoulder and Elbow Surgery, The Christ Hospital, Cincinnati, OH, USA
| |
Collapse
|
2
|
Campbell BR, Schiffman CJ, Chen RE, Wong JC, Horneff JG, Lazarus MD. Clinical and radiographic outcomes of shoulder hemiarthroplasty for patients with glenoid medialization. J Shoulder Elbow Surg 2024:S1058-2746(24)00257-X. [PMID: 38631455 DOI: 10.1016/j.jse.2024.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 02/17/2024] [Accepted: 03/03/2024] [Indexed: 04/19/2024]
Abstract
BACKGROUND Glenoid bone loss in shoulder arthroplasty is a difficult problem that is prone to complications because of challenges with achieving glenoid component fixation and stability. The purpose of this study was to evaluate the outcomes of primary shoulder hemiarthroplasty for patients with severe glenoid medialization precluding placement of a glenoid component. METHODS This was a retrospective case series evaluating patients who underwent shoulder hemiarthroplasty for severe glenoid erosion and medialization between 2010 and 2020. Patients were evaluated via chart review and phone survey to determine if there were any reoperations at final follow-up and to obtain Single Assessment Numeric Evaluation (SANE), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), and Simple Shoulder Test (SST) scores. Preoperative and postoperative radiographs were evaluated and compared to determine glenoid morphology, version, medialization, acromiohumeral distance, and humeral offset. Final postoperative films were also evaluated for anterosuperior migration and signs of mechanical failure, including loosening or periprosthetic fracture. RESULTS Overall, there were 28 patients during this period who underwent shoulder hemiarthroplasty for severe glenoid medialization. Eight patients were deceased at the time of the study, 2 were unable to complete surveys because of dementia, and 7 were lost to follow-up. The final cohort included 11 shoulders and 11 patients with a mean age of 71 ± 7.1 years and mean follow-up of 6.7 years (range 1.6-13.0 years). Mean postoperative SANE, ASES, and SST scores were 80.6 ± 17.6, 71.5 ± 29.3, and 7.6 ± 2.0, respectively. There were no reoperations or revision surgeries at final follow-up. Radiographic evaluation demonstrated severe glenoid medialization and decreased lateral humeral offset, which was unchanged postoperatively. There were 2 patients with signs of anterosuperior migration at final radiographic follow-up but no signs of implant failure. CONCLUSION Shoulder hemiarthroplasty for severe medial glenoid bone loss provides modest clinical outcomes and low rates of reoperation at mid- to long-term follow-up and is an option worth considering in cases where placement of a glenoid component is challenging because of deficient bone stock and high risk for complications.
Collapse
Affiliation(s)
- Benjamin R Campbell
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA.
| | - Corey J Schiffman
- Department of Orthopaedic Surgery and Sports Medicine, University of Washington Medical Center, Seattle, WA, USA
| | - Raymond E Chen
- Department of Orthopaedic Surgery, Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | - Justin C Wong
- Department of Orthopaedic Surgery, OrthoArizona, Glendale, AZ, USA
| | - John G Horneff
- Department of Orthopaedics, University of Pennsylvania, Philadelphia, PA, USA
| | - Mark D Lazarus
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA, USA
| |
Collapse
|
3
|
Berk AN, Cregar WM, Rao AJ, Trofa DP, Schiffern SC, Hamid N, Saltzman BM. Anatomic total shoulder arthroplasty with inlay glenoid component: A systematic review. Shoulder Elbow 2024; 16:119-128. [PMID: 38655412 PMCID: PMC11034471 DOI: 10.1177/17585732231154850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 01/14/2023] [Indexed: 04/26/2024]
Abstract
Background A total shoulder arthroplasty (TSA) system utilizing an inlay glenoid component has been proposed as a means of reducing glenoid component loosening while still providing patients with desirable functional and clinical outcomes. The purpose of this study was to systematically review current outcomes literature on TSA using an inlay glenoid component. Methods A literature search was conducted using PubMed/MEDLINE, Cochrane Database of Systematic Reviews, and Web of Science databases. Studies comparing pre- and postoperative functional and clinical outcomes were included. Results Five studies with 148 shoulders (133 patients) were included. Patient-reported outcomes improved, including the American Shoulder and Elbow Surgeons score (mean change 34.1 to 80.6), Penn Shoulder Score (mean change 43.3 to 85.5), Single Assessment Numeric Evaluation score (mean change 34.1 to 80.6), and visual analog scale-pain (mean change 6.9 to 1.6). Range of motion improved for forward elevation (mean change 109.6 to 156.2) and external rotation (mean change 21.5 to 50.8). Glenoid component loosening occurred in one shoulder (0.68%). Two revision surgeries (1.35%) were performed. Discussion The use of an inlay glenoid component is associated with improvements in postoperative pain, function, and satisfaction while minimizing rates of glenoid component loosening and the need for revision surgery over short-term follow-up. Level of evidence systematic review, level IV.
Collapse
Affiliation(s)
- Alexander N. Berk
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
- Atrium Health—Musculoskeletal Institute,Charlotte, NC, USA
| | - William M. Cregar
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Allison J. Rao
- University of Minnesota Physicians, University of Minnesota—Department of Orthopedic Surgery, Minneapolis, MN, USA
| | - David P. Trofa
- New York Presbyterian, Columbia University Medical Center—Department of Orthopaedics, New York, NY, USA
| | - Shadley C. Schiffern
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Nady Hamid
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
| | - Bryan M. Saltzman
- OrthoCarolina—Sports Medicine Center, Charlotte, NC, USA
- OrthoCarolina Research Institute, Charlotte, NC, USA
- Atrium Health—Musculoskeletal Institute,Charlotte, NC, USA
| |
Collapse
|
4
|
Sears BW, Christensen RG, Kelly JD, Khazzam MS, Mauter LA, Bader JE, Hatzidakis AM. Reliability assessment of new radiographic scales to evaluate radiolucency and bony in-between fin growth of partially cemented all-polyethylene glenoid components. J Shoulder Elbow Surg 2024; 33:872-879. [PMID: 37689103 DOI: 10.1016/j.jse.2023.07.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 07/18/2023] [Accepted: 07/31/2023] [Indexed: 09/11/2023]
Abstract
BACKGROUND Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.
Collapse
Affiliation(s)
| | | | - James D Kelly
- California Pacific Orthopaedics, San Francisco, CA, USA
| | - Michael S Khazzam
- Department of Orthopaedic Surgery; Shoulder Service, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | | | | | | |
Collapse
|
5
|
Hill JR, Olson JJ, Aleem AW, Keener JD, Zmistowski BM. Three-dimensional analysis of biplanar glenoid deformities: what are they and can they be virtually reconstructed with anatomic total shoulder arthroplasty implants? J Shoulder Elbow Surg 2024:S1058-2746(24)00140-X. [PMID: 38423250 DOI: 10.1016/j.jse.2024.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 12/26/2023] [Accepted: 01/01/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND Descriptions of glenoid deformities in glenohumeral osteoarthritis (GHOA) have focused on the axial plane. Less is known regarding arthritic glenoids with higher amounts of superior inclination and little evidence exists to guide management of inclination or combined version-inclination deformity when performing anatomic total shoulder arthroplasty (aTSA). We hypothesized that biplanar deformities (BD) would be present in a higher proportion of GHOA patients than previously appreciated, and these deformities would be difficult to adequately reconstruct with contemporary aTSA implants. METHODS A retrospective query was performed of GHOA patients indicated for TSA 2012-2017 with a computed tomography (CT) scan within three months of surgery. Images were uploaded to three-dimensional (3D) software for automated measurements. Glenoids with superior inclination ≥10°, and retroversion ≥20° were considered to have BD. Walch classification was determined, and C-type glenoids were excluded. Rotator-cuff muscle cross-sectional area (CSA) was measured and fatty infiltration was graded. Glenoids with BD were virtually planned for aTSA with correction to neutral inclination and version, then with 5° superior inclination and 10° retroversion. RESULTS Two-hundred and sixty-eight shoulders in 250 patients were included; average age was 65 years, 67% male. There were no differences in inclination between Walch types (P = .25). Twenty-nine shoulders with BD were identified (11%). These deformities were not associated with age (P = .47) or gender (P = .50) but were skewed towards Walch B-type, specifically B2 (P = .03). Acromial index and posterior humeral head subluxation were higher in BD patients (P = .04, P < .001, respectively). Biplanar deformities had similar cuff CSA compared to those without but were less frequently associated with fatty infiltration of the subscapularis (P = .05). When correcting to neutral version and inclination, 41% BD could not be reconstructed. Of those that could, 94% required augmented implants. When correcting to 5° superior inclination and 10° retroversion, 10% could not be reconstructed. Of those that could, 58% required augmented implants. With partial correction, augment use was predicted by retroversion >26° (P = .009). Inclination did not predict augment use (P = .90). Final implant position commonly involved unseating in the posterosuperior quadrant and cancellous exposure in the anteroinferior quadrant. CONCLUSIONS This retrospective computed tomography (CT)-based study of 268 shoulders with GHOA found an 11% prevalence of BD. These deformities were commonly associated with Walch B2 wear patterns. Virtual aTSA planning showed a high failure rate (41%) when correcting to neutral version and inclination. Posteriorly augmented implants were frequently required, and often still involved unseating in the posterosuperior quadrant, increased cancellous exposure in the anteroinferior quadrant, and vault perforation.
Collapse
Affiliation(s)
- J Ryan Hill
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA; Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA.
| | - Jeffrey J Olson
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Alexander W Aleem
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Jay D Keener
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Benjamin M Zmistowski
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
6
|
Lukasiewicz P, McFarland E, Hassebrock JD, McCarthy TP, Sylvia SM, McCarty EC, Weber SC. Anatomic glenohumeral arthroplasty: State of the art. J ISAKOS 2023; 8:296-305. [PMID: 37207983 DOI: 10.1016/j.jisako.2023.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 04/30/2023] [Accepted: 05/11/2023] [Indexed: 05/21/2023]
Abstract
Anatomical total shoulder arthroplasty in its modern form where it reproduces the normal shoulder has been utilized clinically for more than half a century. As the technology and the designs have changed to recreate the humeral and glenoid sides of the joint, the sophistication of design has resulted in the growing number of cases annually worldwide. This increase is due in part to the increasing number of indications that the prosthesis can treat with successful results. On the humeral side, there have been design changes to better reflect the proximal humeral anatomy, and humeral stems are increasingly placed safely without cement. Platform systems which allow conversion of a failed arthroplasty to a reverse configuration without stem extraction is another design change. Similarly, there has been increasing utilization of short stem and stemless humeral components. Extensive experience with shorter stem and stemless devices, however, has yet to demonstrate the purported advantages of these devices, as recent studies have demonstrated equivalent blood loss, fracture rates, operative times, and outcome scores. Easier revision with these shorter stems remains to be definitively established, with only one study comparing the ease of revision between stem types. On the glenoid side, hybrid cementless glenoids, inlay glenoids, cementless all-polyethylene glenoids, and augmented glenoids have all been investigated; however, the indications for these devices remain unclear. Lastly, innovative surgical approaches to implanting shoulder arthroplasty and the use of patient specific guides and computerized planning, while interesting concepts, still await validation before they are utilized on a widespread basis. While reverse shoulder arthroplasty has been increasingly used to reconstruct the arthritic shoulder, anatomic glenohumeral replacement maintains a significant role in the armamentarium of the shoulder surgeon.
Collapse
Affiliation(s)
- Piotr Lukasiewicz
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA
| | - Edward McFarland
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA
| | - Jeffrey D Hassebrock
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Timothy P McCarthy
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Stephen M Sylvia
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Eric C McCarty
- The University of Colorado School of Medicine, 13001 E 17th Pl, Aurora, CO 80045, USA
| | - Stephen C Weber
- Division of Shoulder Surgery, the Department of Orthopaedic Surgery, The Johns Hopkins University, 733 N Broadway, Baltimore, MD 21205, USA.
| |
Collapse
|
7
|
Evaluation of the Painful Total Shoulder Arthroplasty. J Am Acad Orthop Surg 2023; 31:440-449. [PMID: 36853881 DOI: 10.5435/jaaos-d-22-01006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 01/29/2023] [Indexed: 03/01/2023] Open
Abstract
Despite the overall success of anatomic and reverse total shoulder arthroplasties (aTSA and rTSA), some patients continue to have or develop pain postoperatively. As the number of shoulder arthroplasties continues to increase in the United States, it is important that surgeons are able to recognize, diagnose, and treat the various pathologies. Some painful etiologies are specific to either aTSA or rTSA, and others can occur with both implant types. Infections, stiffness, neurologic syndromes, polyethylene wear, aseptic implant loosening, and metal allergies occur, regardless of implant choice. However, after an aTSA, subscapularis repair failure, superior rotator cuff tear, and joint overstuffing can result in shoulder pain. After a rTSA, specific causes of postoperative pain include instability, scapular notching, acromial or scapular spine fractures, subcoracoid pain, and neurologic injury. Regardless of the diagnosis, the surgeon must be methodical in the evaluation and, when appropriate, use blood work, advanced imaging studies, joint aspirations, shoulder arthroscopy, and nerve studies. Once diagnosed, appropriate treatment should be undertaken to resolve the cause of the pain or at least minimize the effect of the pain on the patient's outcome.
Collapse
|
8
|
Matsui Y, Momma D, Suenaga N, Urita A, Yoshioka C, Oizumi N, Iwasaki N. Computed tomography revealed the correlation between radiolucency and alignment of all-polyethylene pegged glenoid component more than 10 years after total shoulder arthroplasty in the Japanese population. J Orthop Sci 2023; 28:131-137. [PMID: 34838411 DOI: 10.1016/j.jos.2021.10.012] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/24/2021] [Accepted: 10/28/2021] [Indexed: 01/10/2023]
Abstract
BACKGROUND Anatomical total shoulder arthroplasty (TSA) provides successful long-term outcomes but complications can occur after 10 years that require revision. Computed tomography (CT) is a useful tool for assessing radiolucent lines around the glenoid component of TSA; however, the merits of long-term post-TSA follow up with CT are unclear. The purpose of this study was to evaluate the long-term outcomes after TSA of Japanese population and to identify factors related to radiolucency around the glenoid component using CT. METHODS A retrospective review was conducted of TSA patients who had completed at least 10 years of clinical follow up. Radiographs and CT images of the affected shoulder obtained at the last follow up were evaluated for radiolucent lines around the stem and each peg, superior inclination and retroversion of the glenoid component, subluxation index, and critical shoulder angle (CSA). Shoulder ROM, Constant-Murley score and UCLA score were compared between the preoperative and last follow up period. RESULTS Eighteen shoulders in 16 patients met the inclusion criteria. Mean patient age was 61 years, mean follow up period was 137 months, and mean Yian CT score was 19%. CT score was significantly highest in pegs located inferiorly (p < 0.05). Mean glenoid superior inclination was 12.6°, retroversion was -0.3°, subluxation index was 46%, and CSA was 33.7°. Glenoid superior inclination was significantly lower (p = 0.007) in shoulders with possible loosening than in cases with no loosening (5.0° vs 15.6°). Mean Constant score and UCLA score improved significantly after TSA, from 25.8 to 10.7 points preoperatively to 70.1 and 28.9 points postoperatively, respectively. Mean shoulder flexion, internal rotation, and external rotation also showed improvement postoperatively. CONCLUSION TSA provides good long-term outcomes. Radiolucency was present most frequently around the inferior pegs of the glenoid component. Glenoid superior inclination may affect the formation of radiolucent lines around glenoid pegs. LEVEL OF EVIDENCE Level IV; Case Series; Treatment study.
Collapse
Affiliation(s)
- Yuki Matsui
- Faculty of Medicine and Graduate School of Medicine, Department of Orthopaedic Surgery, Hokkaido University, Sapporo, Japan
| | - Daisuke Momma
- Center for Sports Medicine, Hokkaido University Hospital, Sapporo, Japan.
| | | | - Atsushi Urita
- Faculty of Medicine and Graduate School of Medicine, Department of Orthopaedic Surgery, Hokkaido University, Sapporo, Japan
| | | | | | - Norimasa Iwasaki
- Faculty of Medicine and Graduate School of Medicine, Department of Orthopaedic Surgery, Hokkaido University, Sapporo, Japan
| |
Collapse
|
9
|
Liu C, Shi L, Amirouche F. Glenoid Prosthesis Design Considerations in Anatomic Total Shoulder Arthroplasty. J Shoulder Elb Arthroplast 2022; 6:24715492221142856. [PMCID: PMC9742691 DOI: 10.1177/24715492221142856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 11/16/2022] [Indexed: 12/13/2022] Open
Abstract
Total shoulder arthroplasty is an increasingly popular option for the treatment of glenohumeral arthritis. Historically, the effectiveness of the procedure has largely been determined by the long-term stability of the glenoid component. Glenoid component loosening can lead to clinically concerning complications including pain with movement, loss of function, and accumulation of debris which may require surgery to revise. In response, there has been a push to optimize the design of the glenoid prosthesis. Traditional contemporary glenoid components use pegs for fixation and are made entirely of polyethylene. Variations on the standard implant include keeled, metal-backed, hybrid, augmented, and inlay designs. There is a wealth of biomechanical and clinical studies that report on the effectiveness of these different designs. The purpose of this review is to summarize existing literature regarding glenoid component design and identify key areas for future research. Knowledge of the rationale underlying glenoid design will help surgeons select the best component for their patients and optimize outcomes following TSA.
Collapse
Affiliation(s)
- Charles Liu
- The University of Chicago Pritzker School of Medicine, Chicago, IL, USA,Charles Liu, The University of Chicago Pritzker School of Medicine, Chicago, IL, USA.
| | - Lewis Shi
- Department of Orthopaedic Surgery and Rehabilitation Medicine, The University of Chicago Medical Center, Chicago, IL, USA
| | - Farid Amirouche
- Department of Orthopaedics, The University of Illinois at Chicago College of Medicine, Chicago, IL, USA
| |
Collapse
|
10
|
Creighton RA, Burrus MT, Werner BC, Gobezie R, Lederman E, Denard PJ. Short-term clinical and radiographic outcomes of a hybrid all-polyethylene glenoid based on preoperative glenoid morphology. J Shoulder Elbow Surg 2022; 31:2554-2561. [PMID: 35750156 DOI: 10.1016/j.jse.2022.05.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 05/08/2022] [Accepted: 05/23/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The primary purpose of this study was to compare 2-year anatomic total shoulder arthroplasty (TSA) functional and radiographic outcomes between Walch type A and B glenoids treated with an all-polyethylene glenoid designed for hybrid fixation with peripheral cement and central osseous integration. The secondary purpose was to evaluate outcomes based on central peg technique. The hypotheses were that there would be no difference in short-term radiographic or functional outcome scores based on preoperative glenoid morphology or central peg technique. METHODS We performed a multicenter retrospective review of patients who underwent TSA with the same hybrid all-polyethylene glenoid and had minimum 2-year follow-up. Patient-reported outcomes and radiographic outcomes were analyzed based on preoperative Walch morphology and central peg technique. Radiographic analysis included preoperative glenoid morphology; preoperative and postoperative glenoid version, glenoid inclination, and posterior humeral head subluxation; and postoperative glenoid radiolucencies according to the Wirth and Lazarus classifications. RESULTS A total of 266 patients with a mean age of 64.9 ± 8.2 years were evaluated at a mean of 28 months postoperatively. Postoperatively, there were significant improvements in all functional outcome measures (P < .001), range-of-motion measures (forward elevation, external rotation at 0°, external rotation at 90°, internal rotation by spinal level, and internal rotation at 90°; P < .001), and strength measures (Constant, external rotation, and modified belly press; P < .001). There were no clinically meaningful differences in functional outcomes or statistically significant differences in radiographic appearance between Walch type A and B glenoids. Subgroup analysis revealed that glenoids with a cemented central peg had the worst radiographic outcomes based on Lazarus scoring. CONCLUSION Patients undergoing TSA with a hybrid in-line pegged glenoid have excellent clinical outcomes at short-term follow-up regardless of preoperative glenoid morphology. Different central peg techniques do not appear to play a significant role in the risk of glenoid component lucencies at 2 years postoperatively.
Collapse
|
11
|
The 50 Highest Cited Papers on Shoulder Arthroplasty. Healthcare (Basel) 2022; 10:healthcare10102000. [PMID: 36292447 PMCID: PMC9602479 DOI: 10.3390/healthcare10102000] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Revised: 10/03/2022] [Accepted: 10/09/2022] [Indexed: 11/04/2022] Open
Abstract
The purpose of this study was to determine the 50 most cited articles on shoulder arthroplasty (SA) and their characteristics. The Thomson ISIWeb of Science was searched with the following search terms: "shoulder arthroplasty", "shoulder replacement", "shoulder prosthesis" and "shoulder implant". All papers dealing with SA, including its perioperative and postoperative management, were included in this study. Citations ranged from 797 to 52 for the 50 highest cited papers on SA. According to absolute numbers, the top 10 papers were cited at least 118 times. Overall, 78% (n = 43) were clinical and the remaining articles were basic science research (one anatomic, six biomechanical). The most prevalent level of evidence was IV (72%). The Journal of Shoulder and Elbow Surgery published 40% of the studies. The majority of studies were conducted in the United States and eight other countries. The publication years of the most-cited articles ranged from 1991 to 2020, with the 2000s accounting for the most articles (96%) and the period from 2006 to 2010 with the absolute largest number of articles (17). This article provides a building block in the SA surgery.
Collapse
|
12
|
Melvani R, Diaz MA, Wilder L, Christmas KN, Simon P, Cronin KJ, Mighell MA, Frankle MA. Improved mechanical fixation of an all-polyethylene glenoid reduces postoperative radiolucent lines. J Shoulder Elbow Surg 2022; 31:e386-e398. [PMID: 35339705 DOI: 10.1016/j.jse.2022.02.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 02/02/2022] [Accepted: 02/08/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The rationale for advances in implant design is to improve performance in comparison to their predecessors. The purpose of this study was to compare a newer, self-pressurizing peripheral peg glenoid to a traditional polyethylene pegged glenoid through biomechanical evaluation and a retrospective radiographic and clinical review. METHODS Three testing conditions (uncemented, partially cemented, and fully cemented) were chosen to assess the 2 component designs in a foam block model. The number of hammer hits to seat the component, amount of time to seat the component, and resistance-to-seat were collected. The implants were then cyclically loaded following ASTM F2028-17 testing standard. Clinically, postoperative radiographs of patients with a self-pressurized glenoid component (n = 225 patients) and traditional glenoid component (n = 206 patients) were evaluated for radiolucent lines and glenoid seating at various timepoints. Clinical outcomes (American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, Simple Shoulder Test, and visual analog scale pain scores) and complications were recorded. The presence of radiolucent lines at the bone-cement interface was evaluated using the Modified Franklin Grade and the Lazarus grade. RESULTS The self-pressurizing glenoid design required significantly more hammer hits than traditional glenoid designs in all groups tested (P < .029). Moreover, the self-pressurizing design had significantly more resistance-to-seat than traditional components in both the uncemented and partially cemented group (P < .002). No difference in resistance-to-seat was found between designs in the fully cemented group. The uncemented and partially cemented groups did not survive the full 50,000 cycles; however the self-pressurizing design had significantly less motion than the traditional design (P < .001). No differences between component designs were found in the fully cemented group at 50,000 cycles. The self-pressurizing glenoid component had 0.005% radiographic radiolucent lines, and the traditional glenoid component had 45% radiographic radiolucent lines, with 38% of the radiolucencies in the traditional glenoid component group being defined as grade E. There were no progressive radiolucencies, differences in clinical outcomes, or complications at 2 years postoperatively. CONCLUSION In the fully cemented condition, the 2 component designs had comparable performance; however, the differences in designs could be better observed in the uncemented group. The self-pressurizing all-polyethylene design studied has superior biomechanical stability. Clinically, the improved stability of the glenoid component correlated with a reduction of radiolucent lines and will likely lead to a reduction in glenoid component loosening.
Collapse
Affiliation(s)
| | - Miguel A Diaz
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA
| | - Lauren Wilder
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA
| | | | - Peter Simon
- Foundation for Orthopaedic Research and Education, Tampa, FL, USA; Department of Medical Engineering, University of South Florida, Tampa, FL, USA
| | - Kevin J Cronin
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA
| | - Mark A Mighell
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA
| | - Mark A Frankle
- Florida Orthopaedic Institute, Tampa, FL, USA; Department of Orthopaedics and Sports Medicine, University of South Florida Morsani College of Medicine, Tampa, FL, USA.
| |
Collapse
|
13
|
Garrigues GE, Quigley RJ, Johnston PS, Spencer E, Walch G, Neyton L, Kelly J, Schrumpf M, Gillespie R, Sears BW, Hatzidakis AM, Lau B, Lassiter T, Nicholson GP, Friedman L, Hong I, Hagen CJ, Chan W, Naylor A, Blanchard K, Jones N, Poff G, Shea K, Strony J, Mauter L, Finley S, Aitken M. Early clinical and radiographic outcomes of anatomic total shoulder arthroplasty with a biconvex posterior augmented glenoid for patients with posterior glenoid erosion: minimum 2-year follow-up. J Shoulder Elbow Surg 2022; 31:1729-1737. [PMID: 35151882 DOI: 10.1016/j.jse.2021.12.047] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/19/2021] [Accepted: 12/25/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid bone loss in anatomic total shoulder arthroplasty (aTSA) remains a controversial and challenging clinical problem. Previous studies have shown high rates of glenoid loosening for aTSA in shoulders with retroversion, posterior bone loss, and posterior humeral head subluxation. This study is the first to present minimum 2-year follow-up data of an all-polyethylene, biconvex augmented anatomic glenoid component for correction of glenoid retroversion and posterior humeral head subluxation. METHODS This study is a multicenter, retrospective review of prospectively collected data on consecutive patients from 7 global clinical sites. All patients underwent aTSA using the biconvex posterior augmented glenoid (PAG). Inclusion criteria were preoperative computed tomographic (CT) scan, minimum 2 years since surgery, preoperative and minimum 2-year postoperative range of motion examination, and patient-reported outcome measures (PROMs). Glenoid classification, glenoid retroversion, and posterior humeral head subluxation were measured from preoperative CT and radiography and postoperative radiography. Statistical comparisons between pre- and postoperative values were performed with a paired t test. RESULTS Eighty-six of 110 consecutive patients during the study period (78% follow-up) met the inclusion criteria and were included in our analysis. Mean follow-up was 35 ± 10 months, with a mean age of 68 ± 8 years (range 48-85). Range of motion statistically improved in all planes from pre- to postoperation. Mean visual analog scale score improved from 5.2 preoperation to 0.7 postoperation, Single Assessment Numeric Evaluation score from 43.2 to 89.5, Constant score from 41.8 to 76.9, and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form score from 49.8 to 86.7 (all P < .0001). Mean glenoid retroversion improved from 19.3° to 7.4° (P < .0001). Posterior subluxation improved from 69.1% to 53.5% and posterior decentering improved from 5.8% to -3.0% (P < .0001). There was 1 patient with both a prosthetic joint infection and radiographic glenoid loosening that required revision. Seventy-nine of 86 patients had a Lazarus score of 0 (no radiolucency seen about peg or keel) at final follow-up. CONCLUSIONS This study shows that at minimum 2-year follow-up, a posterior-augmented all-polyethylene glenoid can correct glenoid retroversion and posterior humeral head subluxation. Clinically, there was significant improvement in both range of motion and PROMs.
Collapse
Affiliation(s)
| | | | | | | | | | | | - James Kelly
- California Pacific Orthopaedics, San Francisco, CA, USA
| | - Mark Schrumpf
- California Pacific Orthopaedics, San Francisco, CA, USA
| | | | | | | | - Brian Lau
- Duke University Hospital, Durham, NC, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Innovations in Shoulder Arthroplasty. J Clin Med 2022; 11:jcm11102799. [PMID: 35628933 PMCID: PMC9144112 DOI: 10.3390/jcm11102799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2022] [Revised: 05/07/2022] [Accepted: 05/12/2022] [Indexed: 11/22/2022] Open
Abstract
Innovations currently available with anatomic total shoulder arthroplasty include shorter stem designs and augmented/inset/inlay glenoid components. Regarding reverse shoulder arthroplasty (RSA), metal augmentation, including custom augments, on both the glenoid and humeral side have expanded indications in cases of bone loss. In the setting of revision arthroplasty, humeral options include convertible stems and newer tools to improve humeral implant removal. New strategies for treatment and surgical techniques have been developed for recalcitrant shoulder instability, acromial fractures, and infections after RSA. Finally, computer planning, navigation, PSI, and augmented reality are imaging options now available that have redefined preoperative planning and indications as well intraoperative component placement. This review covers many of the innovations in the realm of shoulder arthroplasty.
Collapse
|
15
|
Hornung AL, Cohn MR, Mehta N, McCormick JR, Menendez ME, Pourzal R, Nicholson GP, Garrigues GE. The Definition of Periprosthetic Osteolysis in Shoulder Arthroplasty: A Systematic Review of Grading Schemes and Criteria. JBJS Rev 2022; 10:01874474-202205000-00011. [PMID: 35613304 DOI: 10.2106/jbjs.rvw.22.00002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
BACKGROUND Periprosthetic osteolysis is a known complication after shoulder arthroplasty that may lead to implant loosening and revision surgery. To date, there is no consensus in the shoulder arthroplasty literature regarding the definition of osteolysis or the grading criteria, thus making it difficult to quantify and compare outcomes involving this complication. The purpose of this study was to perform a systematic review of the literature to assess how periprosthetic osteolysis in shoulder arthroplasty is defined and evaluated radiographically. METHODS A systematic review of MEDLINE, Scopus, Cochrane, and CINAHL was performed in August 2021 for studies that provided a definition and/or grading criteria for osteolysis in shoulder arthroplasty. Only studies with a minimum of 2 years of radiographic follow-up were included. RESULTS Thirty-four articles met the inclusion criteria. After consolidating studies by the same primary author that included the same grading criteria, 29 studies were examined for their definition and grading criteria for osteolysis. Of these, 19 (65.5%) evaluated osteolysis surrounding the glenoid and 18 (62.1%) evaluated osteolysis surrounding the humerus. There was considerable heterogeneity in the systems used to grade periprosthetic osteolysis surrounding the glenoid, whereas humeral periprosthetic osteolysis was often categorized via visualization into binary or categorical groups (e.g., presence versus absence; mild, moderate, or severe; partial versus complete). Four studies (13.8%) provided novel measurements for assessing either glenoid or humeral osteolysis. CONCLUSIONS Considerable heterogeneity exists in the assessment and grading of periprosthetic osteolysis in shoulder arthroplasty. The most common grading systems were binary and used qualitative visual interpretation, making them relatively subjective and prone to bias. Quantitative measurements of osteolysis were infrequently utilized. A standardized method of assessing osteolysis would be of value to facilitate communication and research efforts.
Collapse
Affiliation(s)
- Alexander L Hornung
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, Illinois
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Haleem A, Sedrak P, Gohal C, Athwal GS, Khan M, Alolabi B. Hybrid Glenoid Designs in Anatomic Total Shoulder Arthroplasty: A Systematic Review. HSS J 2022; 18:219-228. [PMID: 35645649 PMCID: PMC9096999 DOI: 10.1177/15563316211040829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. QUESTIONS/PURPOSE We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. METHODS PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. RESULTS Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. CONCLUSION Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.
Collapse
Affiliation(s)
- Ahmed Haleem
- Faculty of Health Sciences, McMaster
University, Hamilton, ON, Canada
| | - Phelopater Sedrak
- Faculty of Health Sciences, McMaster
University, Hamilton, ON, Canada
| | - Chetan Gohal
- Division of Orthopaedic Surgery,
Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - George S. Athwal
- Schulich School of Medicine &
Dentistry, Western University, London, ON, Canada
| | - Moin Khan
- Division of Orthopaedic Surgery,
Department of Surgery, McMaster University, Hamilton, ON, Canada
- St. Joseph’s Healthcare Hamilton,
Hamilton, ON, Canada
- Moin Khan, MD, MSc, FRCSC, St. Joseph’s
Healthcare Hamilton, 50 Charlton Ave E., Mary Grace Wing, Room G807, Hamilton,
ON L8N 4A6, Canada.
| | - Bashar Alolabi
- Division of Orthopaedic Surgery,
Department of Surgery, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
17
|
Altintas B, Horan MP, Dornan GJ, Pogorzelski J, Godin JA, Millett PJ. The Recovery Curve of Anatomic Total Shoulder Arthroplasty for Primary Glenohumeral Osteoarthritis: Mid-term Results at a Minimum of 5 Years. JSES Int 2022; 6:587-595. [PMID: 35813142 PMCID: PMC9264145 DOI: 10.1016/j.jseint.2022.04.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background Excellent results have been reported for anatomic total shoulder arthroplasty (TSA) for the treatment of primary glenohumeral osteoarthritis (GHOA). We aim to assess the recovery curve and longitudinal effects of time, age, sex, and glenoid morphology on patient-reported outcomes (PROs) after primary anatomic TSA for primary GHOA. Methods Patients who underwent primary anatomic TSA over 5 years ago were included: Short-Form 12 Physical Component Summary, American Shoulder and Elbow Surgeons scores, Quick Disabilities of the Arm Shoulder and Hand Score, Single Assessment Numeric Evaluation, and patient satisfaction were assessed. Linear mixed-effects models were used to model progression in PROs longitudinally. Unadjusted models and models controlling for sex and age were constructed. Results Eighty-one patients (91 shoulders) were included. Significant improvements from the preoperative period to 1 year postoperatively in the median American Shoulder and Elbow Surgeons (48 to 93; P < .001), Quick Disabilities of the Arm Shoulder and Hand Score (42 to 11; P < .001), Single Assessment Numeric Evaluation (50 to 91; P < .001), and Short-Form 12 Physical Component Summary (35 to 53; P = .004) scores were noted. No significant decrease was observed for any of the outcome scores. Median satisfaction at the final follow-up was 10 out of 10. At 1, 2, 3, 4, 5, 6, and 7 years postoperatively, 77%, 64%, 79%, 57%, 86%, 56%, and 78% of patients, respectively, reported sports participation equal to or slightly below preinjury level. There was no association between the glenoid morphology and functional outcomes. Conclusion Patients undergoing anatomic TSA for primary GHOA showed excellent improvement in PROs and satisfaction in the first year, and these results were maintained postoperatively for a minimum of 5 years. Age- and sex-adjusted models or glenoid morphology did not substantially alter any trends in PROs postoperatively.
Collapse
Affiliation(s)
- Burak Altintas
- Steadman Philippon Research Institute, Vail, CO, USA
- Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA
| | | | | | - Jonas Pogorzelski
- Steadman Philippon Research Institute, Vail, CO, USA
- Department of Orthopaedic Sports Medicine, Hospital Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jonathan A. Godin
- Steadman Philippon Research Institute, Vail, CO, USA
- The Steadman Clinic, Vail, CO, USA
| | - Peter J. Millett
- Steadman Philippon Research Institute, Vail, CO, USA
- The Steadman Clinic, Vail, CO, USA
- Corresponding author: Peter J. Millett, MD, MSc, Steadman Philippon Research Institute, The Steadman Clinic, 181 West Meadow Drive, Suite 400, Vail, CO 81657, USA.
| |
Collapse
|
18
|
Malahias MA, Kostretzis L, Gkiatas I, Chronopoulos E, Brilakis E, Antonogiannakis E. Clinical and radiographic outcomes of total shoulder arthroplasty with a partially cemented all-polyethylene pegged bone-ingrowth glenoid component: a systematic review. Shoulder Elbow 2021; 13:627-641. [PMID: 34804212 PMCID: PMC8600676 DOI: 10.1177/1758573220944168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2020] [Accepted: 06/21/2020] [Indexed: 11/15/2022]
Abstract
BACKGROUND Several articles have been published reporting on the clinical performance of a novel pegged, all-polyethylene glenoid component design which features a central peg, circumferentially fluted, interference-fit peg for tissue integration and three small peripheral pegs for cementing. However, no systematic review exists to this date. METHODS The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried for publications up to May 2020. RESULTS Overall, 13 articles were included for analysis (560 operated shoulders, range of mean follow-up: 2-6 years). The survival rate was 98.2% (550 out of 560 cases), while the rate of aseptic loosening was 0.2% (1 out of 560 cases). There were 139 cases (out of 399 reported; 34.1%) with peri-glenoid radiolucency, and 35 cases (out of 223 reported; 15.7%) of asymptomatic central peg osteolysis, with 1 of them undergoing revision. CONCLUSIONS There was fair quality of evidence to show that partially cemented all-polyethylene pegged bone-ingrowth glenoid components produce promising results, with a low revision rate in the short- to medium-term follow-up. Nevertheless, this analysis showed high rates of both radiolucency of the glenoid component and osteolysis around the central peg which raise concern for potential failure of this glenoid component in the long-term follow-up. LEVEL OF EVIDENCE Systematic review, IV.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- 3rd Orthopaedic Department, Hygeia
Hospital, Athens, Greece,The Stavros Niarchos Foundation Complex
Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Lazaros Kostretzis
- 2nd Orthopaedic Department, Aristotle
University of Thessaloniki, G.Gennimatas General Hospital, Thessaloniki,
Greece,Lazaros Kostretzis, 2nd Orthopaedic
Department, Aristotle University of Thessaloniki, G.Gennimatas General Hospital,
Eth. Aminis 41, Thessaloniki, Greece.
| | - Ioannis Gkiatas
- The Stavros Niarchos Foundation Complex
Joint Reconstruction Center, Hospital for Special Surgery, New York, NY, USA
| | - Efstathios Chronopoulos
- 2nd Orthopaedic Department, National
& Kapodistrian University of Athens, School of Medicine, Athens, Greece
| | | | | |
Collapse
|
19
|
Ho JC, Ricchetti ET, Iannotti JP. Central-peg radiolucency progression of an all-polyethylene glenoid with hybrid fixation in anatomic total shoulder arthroplasty is associated with clinical failure and reoperation. J Shoulder Elbow Surg 2021; 30:1068-1077. [PMID: 32791097 DOI: 10.1016/j.jse.2020.07.039] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 07/13/2020] [Accepted: 07/19/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid component loosening is a common cause of failure after anatomic total shoulder arthroplasty. Prior studies of all-polyethylene glenoid implants with hybrid fixation did not show early glenoid radiolucency to be clinically significant. The purpose of this study was to determine the clinical significance of progression of radiolucency around the central peg of the glenoid component. METHODS We identified 73 shoulders that underwent primary anatomic total shoulder arthroplasty between January 1995 and May 2015 for osteoarthritis with an all-polyethylene pegged glenoid, with a minimum follow-up interval of 2 years between early and late follow-up. Demographic, radiographic (central-peg osteolysis [CPO] and central-peg grading [CPG]), and outcome variables comprising the Penn Shoulder Score (PSS) and revision surgery were collected. Clinical failure was defined as a PSS decrease >11.4 points (ie, PSS failure) or revision surgery. RESULTS The average patient age at surgery was 65 ± 7 years, and 63% of patients were men. The median initial follow-up period was 14 months (interquartile range, 12-25 months), and the final median follow-up period was 56 months (interquartile range, 47-69 months). Revision surgical procedures were performed in 4 patients, and 17 PSS failures occurred. We found that CPO at final follow-up, CPG progression, and worse PSS at follow-up were associated with revision surgery (P < .05). We also found younger age at surgery, CPO at final follow-up, CPG progression, and greater glenoid component retroversion at final follow-up to be associated with clinical failure (PSS failure or revision surgery) (P < .05). Multivariate analysis found only CPG progression to be associated with clinical failure (P < .001). DISCUSSION AND CONCLUSION CPO and CPG progression were associated with clinical failure, defined as decreasing clinical outcome scores or revision surgery.
Collapse
Affiliation(s)
- Jason C Ho
- Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA.
| | - Eric T Ricchetti
- Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Joseph P Iannotti
- Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
20
|
Borbas P, Taylor DM, Lee S, Wijeratna M, Hoy G, Evans MC. Medium-Term Clinical and Radiographic Results of an All-Polyethylene, Pegged, Bone-Ingrowth Glenoid Component: A Concise Follow-up of a Previous Report. J Bone Joint Surg Am 2021; 103:251-256. [PMID: 33534293 DOI: 10.2106/jbjs.20.00084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
ABSTRACT We previously reported the mean 4-year outcomes of anatomic total shoulder replacement using an all-polyethylene, pegged, hybrid-fixation (bone ingrowth and cement) glenoid component. In the present study, we report on that patient cohort after another 4 years of follow-up (mean, 101 months; range, 77 to 146 months). At that time, the median American Shoulder and Elbow Surgeons (ASES) score was 92 points (interquartile range [IQR], 81.7 to 98.3) and the median Oxford Shoulder Score was 47 points (IQR, 41 to 48). Osseointegration, demonstrated by bone ingrowth between the flanges on the central peg as seen on coronal computed tomography (CT), was complete in 75% of the shoulders, partial in 21%, and absent in 4%. There were radiolucent lines at the bone-prosthesis interface on CT, with a median Yian score of 1 (IQR, 0 to 2; range, 0 to 18). The conclusion in the present study was that shoulder arthroplasty with an all-polyethylene, hybrid-fixation (bone ingrowth and cement) pegged glenoid component has durable clinical and radiographic outcomes at medium-term follow-up. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Paul Borbas
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia.,Department of Orthopaedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | | | - Steven Lee
- The Avenue Hospital, Windsor, Victoria, Australia
| | - Malin Wijeratna
- Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom
| | - Gregory Hoy
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia.,Austin Hospital, Heidelberg, Victoria, Australia.,Department of Surgery, Monash University, Melbourne, Victoria, Australia
| | - Matthew C Evans
- Melbourne Orthopaedic Group, Windsor, Victoria, Australia.,Department of Surgery, Monash University, Melbourne, Victoria, Australia
| |
Collapse
|
21
|
Henderson DJH, Christensen TJ, Vo A, Plath JE, Popescu IA, Lafosse L. The V-shaped subscapularis tenotomy for anatomic total shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2020; 45:199-208. [PMID: 33210169 DOI: 10.1007/s00264-020-04880-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 11/09/2020] [Indexed: 11/30/2022]
Abstract
PURPOSE Management of the subscapularis tendon during anatomic total shoulder arthroplasty (TSA) remains controversial. In our unit, subscapularis tenotomy is the preferred technique; however, the potential for tendon gapping and failure is recognised. The purpose of this study is to describe and provide early clinical results of a novel, laterally based V-shaped tenotomy (VT) technique hypothesised to provide greater initial repair strength and resistance to gapping than a transverse tenotomy (TT), with both clinically and radiologically satisfactory post-operative tendon healing and function. METHODS A retrospective study of patients who underwent primary TSA with VT over a three year period was performed using shoulder and subscapularis-specific outcome scores, radiographs, and ultrasound. A separate cohort of patients who underwent TSA using a subscapularis sparing approach was also reviewed to provide comparative clinical outcomes of a group with TSA and an un-violated subscapularis. RESULTS Eighteen patients were reviewed at mean 30.4 months (± 11.7). Constant (78.2 ± 12.3), UCLA (8.4 ± 1.5), pain VAS (2.3 ± 2.8), and strength in internal rotation were no different from the comparison group. Likewise, neither were the clinical outcomes of range-of-motion, belly-press, lift-off, and shirt-tuck tests. One patient (5.5%) was found to have a failed subscapularis repair on ultrasound. CONCLUSION VT during TSA appears to provide healing rates at least equal to those reported for TT, and not dissimilar from those of lesser tuberosity osteotomy. Clinical outcomes are comparable to reported results in the literature for alternative techniques, and not different from those observed here in a comparison cohort with TSA performed without violating the subscapularis tendon. VT therefore potentially offers a more effective and secure tendon repair than a traditional TT, with at least comparable clinical outcomes.
Collapse
Affiliation(s)
- Daniel J H Henderson
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France. .,Department of Trauma & Orthopaedics & Leeds Biomedical Research Centre, Chapel Allerton Hospital, Leeds, LS7 4SA, UK.
| | - Thomas J Christensen
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France.,Reno Orthopaedic Clinic, Reno, NV, USA
| | - Austin Vo
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France.,Austin & Monash Health, Melbourne, Australia
| | - Johannes E Plath
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France.,Department of Trauma, Orthopaedic, Plastic & Hand Surgery, Zentralklinikum, Augsburg, Augsburg, Germany
| | - Ion-Andrei Popescu
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France.,European Shoulder & Hand Unit, Bucharest, Romania
| | - Laurent Lafosse
- Alps Surgery Institute, Clinique Générale d'Annecy, 4 Chemin de la Tour la Reine, 74000, Annecy, France
| |
Collapse
|
22
|
Matsen FA, Whitson AJ, Somerson JS, Hsu JE. Anatomic Total Shoulder Arthroplasty with All-Polyethylene Glenoid Component for Primary Osteoarthritis with Glenoid Deficiencies. JB JS Open Access 2020; 5:JBJSOA-D-20-00002. [PMID: 33376930 PMCID: PMC7757838 DOI: 10.2106/jbjs.oa.20.00002] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
This study evaluated the ability of shoulder arthroplasty using a standard glenoid component to improve patient self-assessed comfort and function and to correct preoperative humeral-head decentering on the face of the glenoid in patients with primary glenohumeral arthritis and type-B2 or B3 glenoids.
Collapse
Affiliation(s)
- Frederick A Matsen
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| | - Anastasia J Whitson
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| | | | - Jason E Hsu
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, Washington
| |
Collapse
|
23
|
Jacxsens M, Dayerizadeh N, Vandenbosch D, Van Tongel A, De Wilde L. Clinical and radiographic outcomes of an all-polyethylene fluted central peg glenoid component, implanted utilizing an off-label, uncemented technique, at a minimum 5-year follow-up. J Shoulder Elbow Surg 2020; 29:2292-2298. [PMID: 32499196 DOI: 10.1016/j.jse.2020.02.027] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 02/13/2020] [Accepted: 02/20/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid component loosening remains an important concern in anatomic total shoulder arthroplasty. The aim of this study was to evaluate the clinical and radiographic results of a fully uncemented all-polyethylene fluted central peg bone-ingrowth glenoid component at a minimum 5-year follow-up. METHODS Thirty-five shoulders in 31 patients (mean age, 73 years) with a mean follow-up of 100 months were retrospectively evaluated at an early and mid-term time point for Constant score (CS). Computed tomography visualized glenoid component fixation at both time points. RESULTS Mean CS improved from 40 preoperatively to 66 postoperatively at latest follow-up (P < .001). A mean CS of 74 at early follow-up remained consistent with a mean CS of 66 at latest follow-up (P = .158), with only strength demonstrating a decrease over time (P < .001). An initial osseointegration rate of 81% at early follow-up decreased to 71% at latest follow-up with 74% of the shoulders demonstrating progressive radiolucent lines, resulting in a radiographic loosening rate of 31%. Of the 35 shoulders, 4 were revised (survival rate of 88%), of which 2 due to symptomatic aseptic loosening. CONCLUSIONS Uncemented fixation of an all-polyethylene central peg bone-ingrowth glenoid was associated with satisfactory clinical and radiographic scores, and an acceptable revision rate at mid- to long-term follow-up. Despite initial bony osseointegration in the majority of cases, radiographic loosening over time remains a concern, potentially jeopardizing long-lasting fixation of this type of glenoid component when implanted in an off-label uncemented fashion.
Collapse
Affiliation(s)
- Matthijs Jacxsens
- Department of Orthopaedics and Traumatology, Ghent University Hospital, Ghent, Belgium; Department of Orthopaedics and Traumatology, Kantonsspital St. Gallen, St. Gallen, Switzerland
| | - Nader Dayerizadeh
- Department of Orthopaedics and Traumatology, Ghent University Hospital, Ghent, Belgium
| | - Dominiek Vandenbosch
- Department of Rehabilitation Sciences and Physiotherapy, Ghent University Hospital, Ghent, Belgium
| | - Alexander Van Tongel
- Department of Orthopaedics and Traumatology, Ghent University Hospital, Ghent, Belgium
| | - Lieven De Wilde
- Department of Orthopaedics and Traumatology, Ghent University Hospital, Ghent, Belgium.
| |
Collapse
|
24
|
Dillon MT, Chan PH, Prentice HA, Burfeind WE, Yian EH, Singh A, Paxton EW, Navarro RA. The association between glenoid component design and revision risk in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg 2020; 29:2089-2096. [PMID: 32507730 DOI: 10.1016/j.jse.2020.02.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2019] [Revised: 02/10/2020] [Accepted: 02/20/2020] [Indexed: 02/01/2023]
Abstract
INTRODUCTION Anatomic total shoulder arthroplasty (TSA) is a proven treatment for glenohumeral joint osteoarthritis, with superior results compared with hemiarthroplasty. However, glenoid component loosening remains a problem and is one of the most common causes of failure in TSA. Multiple component designs have been developed in an attempt to reduce loosening rates. The purpose of this study was to evaluate risk of revision after anatomic TSA according to the glenoid component design. METHODS We conducted a cohort study including patients aged ≥18 years who underwent primary elective TSA for the diagnosis of osteoarthritis between 2010 and 2017. Patients with missing implant information, who received stemless humeral implants, or who received augmented glenoid implants, were excluded. Glenoid component designs used were categorized into 4 mutually exclusive treatment groups: polyethylene central-pegged ingrowth, polyethylene-metal hybrid, polyethylene all-cemented pegged, and polyethylene cemented keeled. Multivariable competing risk regression was used to evaluate the risk of glenoid loosening as a cause-specific revision by the glenoid component design. RESULTS Of the 5566 TSA included in the final cohort, 39.2% of glenoid implants were polyethylene central-pegged ingrowth, 31.1% were polyethylene-metal hybrid, 26.0% were polyethylene all-cemented pegged, and 3.6% were polyethylene cemented keeled. At 6-year final follow-up, 4.1% of TSA were revised for any cause, and 1.4% for glenoid loosening. Compared with the polyethylene central-pegged ingrowth design, no difference in glenoid loosening revision risk was observed for the polyethylene-metal hybrid design (hazard ratio [HR] = 1.15, 95% confidence interval [CI] = 0.42-3.20). However, both the polyethylene all-cemented pegged (HR = 2.48, 95% CI = 1.08-5.66) and polyethylene cemented keeled (HR = 3.84, 95% CI = 1.13-13.00) designs had higher risks for revision due to glenoid loosening. CONCLUSIONS We observed glenoid component designs to be associated with differential risks in revision due to glenoid loosening with polyethylene all-cemented pegged glenoids and polyethylene cemented keeled glenoids having higher risks when compared with polyethylene central-pegged ingrowth glenoids. Surgeons may want to consider the glenoid component design when performing anatomic TSA.
Collapse
Affiliation(s)
- Mark T Dillon
- Department of Orthopaedics, The Permanente Medical Group, Sacramento, CA, USA.
| | - Priscilla H Chan
- Surgical Outcomes and Analysis, Kaiser Permanente, San Diego, CA, USA
| | | | | | - Edward H Yian
- Department of Orthopaedics, Southern California Permanente Medical Group, Anaheim, CA, USA
| | - Anshuman Singh
- Department of Orthopaedics, Southern California Permanente Medical Group, San Diego, CA, USA
| | | | - Ronald A Navarro
- Department of Orthopaedics, Southern California Permanente Medical Group, Harbor City, CA, USA
| |
Collapse
|
25
|
Schiefer M, Siqueira G, Figueira A, Souza PM, Monteiro MT, Motta Filho G. Integração óssea e prevalência de linhas radiotransparentes ao redor dos pinos de componentes glenoidais minimamente cimentados na artroplastia total de ombro. Rev Bras Ortop 2020; 57:120-127. [PMID: 35198119 PMCID: PMC8856858 DOI: 10.1055/s-0040-1715509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 06/01/2020] [Indexed: 11/21/2022] Open
Abstract
Objectives
Glenoid component failure is the main cause of total shoulder arthroplasty (TSA) revision, and component design seems to influence the failure rate. The aim of the present study was to clinically and radiographically (through X-rays and computed tomography scan) evaluate the results of TSA using a minimally cemented glenoid component.
Methods
Total should arthroplasties performed using the minimally cemented Anchor Peg (DuPuy Synthes, Warsaw, IN, USA) glenoid component between 2008 and 2013 were evaluated. University of California at Los Angeles (UCLA) scores were calculated, and standardized plain film and computed tomography images were obtained, at a minimum follow-up of 24 months. The presence of bone between the fins of the central component peg, which indicates its integration, was assessed on the images, as well the presence of radiolucent lines around the glenoid component.
Results
Nineteen shoulders in 17 patients were available for evaluation. According to the UCLA score, clinical results were satisfactory in 74% of cases and fair in 21% of cases. One patient had a poor result. Component integration was found in 58% of patients (total in 42% and partial in 16%). Radiolucent lines were observed in 52% of cases. No relationship was detected between component integration and clinical results.
Conclusion
Satisfactory clinical results were achieved in most patients undergoing TSA using a minimally cemented glenoid component. Radiolucent lines around the glenoid component are common, but do not interfere with the clinical results.
Level of evidence
IV; Case series; Treatment study.
Collapse
Affiliation(s)
- Márcio Schiefer
- Departamento de Ortopedia, Faculdade de Medicina, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brasil
- Departamento de Ortopedia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| | - Gláucio Siqueira
- Departamento de Ortopedia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| | - Alan Figueira
- Departamento de Ortopedia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| | - Patrícia Martins Souza
- Departamento de Radiologia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| | - Martim Teixeira Monteiro
- Departamento de Ortopedia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| | - Geraldo Motta Filho
- Departamento de Ortopedia, Instituto Nacional de Ortopedia e Traumatologia (INTO), Rio de Janeiro, RJ, Brasil
| |
Collapse
|
26
|
Denard PJ, Gobezie R, Griffin JW, Romeo AA, Lederman E. Osseous Integration of the Central Peg of an All-Polyethylene Glenoid With 3 Different Surgical Techniques. Orthopedics 2020; 43:278-283. [PMID: 32745227 DOI: 10.3928/01477447-20200721-04] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 04/23/2020] [Indexed: 02/03/2023]
Abstract
All-polyethylene glenoid components designed for osseous integration of the central peg can be placed with no graft (NG), autogenous bone graft (ABG), or demineralized bone matrix (DBM). The purpose of this study was to compare osseous integration with these 3 techniques. A randomized controlled trial was performed of 153 total shoulder arthroplasties using a pegged allpolyethylene glenoid component designed for osseous integration. Central peg treatment included NG, ABG, or DBM. The primary outcome was central peg osseous integration defined as bone presence between the central fins 1 year postoperatively. Central osseous integration was observed in 90% of cases treated with ABG, 68% of cases treated with DBM, and 68% of cases treated with NG (P=.022). Postoperative Wirth grading revealed radiolucency around the central peg (grade 1) in 2.4% of cases with ABG, 5.4% of cases with DBM, and 9.8% of cases with NG (P=.134). At short-term follow-up, osseous integration of the central peg of an all-polyethylene glenoid designed for bony growth between the central fins appears to be highest when treating the central peg with ABG compared with leaving the central peg untreated or using DBM. [Orthopedics. 2020;43(5):278-283.].
Collapse
|
27
|
Malahias MA, Kostretzis L, Gkiatas I, Chronopoulos E, Brilakis E, Antonogiannakis E. Total shoulder arthroplasty with hybrid fixation of glenoid components consisting of cementless porous metal pegs or cage along with cemented backside polyethylene surface: a systematic review. Musculoskelet Surg 2020; 104:229-236. [PMID: 32529404 DOI: 10.1007/s12306-020-00670-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 06/04/2020] [Indexed: 11/26/2022]
Abstract
Recently, hybrid glenoid components have been developed, consisting of cementless highly porous metal central peg, monoblock keel or cage along with cemented backside polyethylene surface. The aims of this study were twofold: (1) to determine the revision and complication rates of hybrid glenoid components, consisting of porous metal pegs or coatings attached to the polyethylene, for aseptic loosening in TSA and (2) to evaluate the rate of radiolucent lines in patients who underwent TSA with hybrid glenoid components consisting of porous metal pegs or coatings attached to the polyethylene. The US National Library of Medicine (PubMed/MEDLINE), EMBASE and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: "hybrid" OR "bone-ingrowth" OR "bone ingrowth" AND "TSA" OR "total" AND "shoulder" AND "arthroplasty" OR "replacement". Five articles were included for analysis (470 operated shoulders, mean follow-up: 47.5 months). The overall weighted mean modified methodology Coleman score was 51.2/100, indicating a moderate level of overall methodological quality. The survival rate of hybrid glenoid components was 97.4% (458 out of 470 cases), while the rate of glenoid-related complications was 2.8% (13 cases). Finally, there were 54 cases (out of 313 reported; 17.3%) with glenoid radiolucency (none of them required revision). TSA with hybrid fixation glenoid components was associated with high survivorship and low rate of glenoid component-related complications at 4 years mean follow-up. In addition, there was limited evidence to show that the short- to mid-term outcome of TSA using hybrid glenoid components is not inferior to the outcome of cemented all-polyethylene glenoid components.
Collapse
Affiliation(s)
- M-A Malahias
- 3rd Orthopaedic Department, Hygeia Hospital, Erythrou Stavrou 4, Marousi, 15123, Athens, Greece
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
| | - L Kostretzis
- HKF Zentrum, ATOS Klinik, Bismarckstrasse 9-15, 69115, Heidelberg, Germany
| | - I Gkiatas
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| | - E Chronopoulos
- 2nd Orthopaedic Department, School of Medicine, National and Kapodistrian University of Athens, Agias Olgas 3, Nea Ionia, 14233, Athens, Greece
| | - E Brilakis
- 3rd Orthopaedic Department, Hygeia Hospital, Erythrou Stavrou 4, Marousi, 15123, Athens, Greece
| | - E Antonogiannakis
- 3rd Orthopaedic Department, Hygeia Hospital, Erythrou Stavrou 4, Marousi, 15123, Athens, Greece
| |
Collapse
|
28
|
Jung HJ, Nam TS, Park D, Jeon IH. Three-Dimensional Morphometric Analysis of Penetrative Depth and Size of Nonarthritic and Degenerative Arthritic Glenoids: Implications for Glenoid Replacement in Shoulder Arthroplasty. Clin Orthop Surg 2020; 12:224-231. [PMID: 32489545 PMCID: PMC7237260 DOI: 10.4055/cios19088] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 07/25/2019] [Indexed: 11/15/2022] Open
Abstract
Background Shoulder arthroplasty is technically demanding and relies heavily on the precision of surgical techniques. Proper glenoid component sizing plays a crucial role in successful shoulder arthroplasty. We measured the size and penetrative depth of the glenoid for peg or screw fixation in nonarthritic and degenerative arthritic shoulders by using three-dimensional computed tomography to determine the reference dimensions of the glenoid in nonarthritic and degenerative arthritic shoulders. Methods From January 2010 to January 2011, data on two groups of patients were collected and reviewed. Group 1 comprised 38 patients who underwent surgical treatment due to fracture of the proximal humerus and who had no evidence of a pathological glenoid. Group 2 comprised 14 patients who underwent surgical treatment due to osteoarthritis of the glenohumeral joint. The height (maximal superoinferior diameter) of the glenoid was measured, and the width (anteroposterior [AP] diameter) of the glenoid was measured at five different levels (H1–H5). Axial images were taken at H1–H5 levels, the AP glenoid diameter of each was divided into eight areas, and division points were labeled as W1–W7. The penetrative depths between the near cortex and far cortex of the glenoid (thickness) at each point (W1–W7) were measured. Results The overall mean glenoid height was 37.67 ± 4.09 mm in nonarthritic glenoids and 39.42 ± 3.54 mm in degenerative arthritic glenoids. The nonarthritic glenoid was significantly thicker than the degenerative arthritic glenoid at the H1W3, H1W4, H1W5, H2W7, H3W1, H3W6, H3W7, H4W5, H4W6, H4W7, H5W4, H5W5, H5W6, and H5W7 points. The posteroinferior quadrant had the smallest penetrative depth in both nonarthritic and degenerative arthritic glenoids. Also, the degenerative arthritic glenoids were significantly thinner than the nonarthritic glenoids along the posterior and inferior parts of the glenoid. Conclusions The posterior and inferior parts of the degenerative arthritic glenoid appears thinner than the nonarthritic glenoid. Thus, caution has to be taken when drilling the screw hole or inserting screws into the posteroinferior parts, where the glenoid is thinner than 15 mm on average, to avoid penetration of the far cortex.
Collapse
Affiliation(s)
- Hong Jun Jung
- Department of Orthopedic Surgery, Sahmyook Medical Center, Seoul, Korea
| | - Tae-Seok Nam
- Department of Orthopedic Surgery, Sahmyook Medical Center, Seoul, Korea
| | - Daewon Park
- Department of Orthopedic Surgery, Sahmyook Medical Center, Seoul, Korea
| | - In-Ho Jeon
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
29
|
Schoch BS, Zarezadeh A, Priddy M, King JJ, Wright TW. Uncemented fixation of a monoblock ingrowth polyethylene glenoid: early follow-up. J Shoulder Elbow Surg 2020; 29:968-975. [PMID: 31812586 DOI: 10.1016/j.jse.2019.09.034] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Revised: 09/03/2019] [Accepted: 09/12/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Traditional monoblock pegged glenoid components are implanted with cement, increasing operative time and potentially violating more bone than those inserted without cement. We study the early radiographic loosening and reoperation rate following uncemented fixation of a hybrid cage monoblock polyethylene glenoid component. METHODS Between 2013 and 2015, a total of 51 shoulders underwent anatomic shoulder arthroplasty (TSA) using a hybrid ingrowth cage polyethylene glenoid component by a single surgeon, with a minimum follow-up of 2 years. In all cases, the glenoid component was placed without cement. Mean follow-up was 33 months (range, 24-57). The primary outcome was Lazarus scale-assessed radiographic loosening. Secondary outcomes included reoperation, range of motion (ROM), and patient-reported outcome measures (PROMs). RESULTS Twelve glenoid components (24%) had radiolucent lines. Glenoid lines were rated grade 1, grade 2, and grade 5 (6, 4, and 2 shoulders, respectively). Six shoulders (12%) had humeral lucent lines. Two shoulders (4%) underwent reoperation, only 1 of these occurring due to isolated failure of the glenoid component. As a group, mean ROM and PROMs improved significantly compared with preoperative values and exceeded the minimal clinically important difference. CONCLUSION Glenoid loosening remains a major concern at mid- to long-term follow-up of TSA. Placement of this hybrid cage monoblock polyethylene glenoid component in a completely uncemented fashion does not lead to early clinical loosening, after which bony ingrowth into the central cage can be expected. Uncemented fixation of this hybrid cage component appears to be a safe treatment option for patients undergoing primary TSA.
Collapse
Affiliation(s)
- Bradley S Schoch
- Department of Orthopedic Surgery, Mayo Clinic, Jacksonville, FL, USA.
| | - Ali Zarezadeh
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Michael Priddy
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Joseph J King
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | - Thomas W Wright
- Department Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| |
Collapse
|
30
|
Kim DM, Aldeghaither M, Alabdullatif F, Shin MJ, Kholinne E, Kim H, Jeon IH, Koh KH. Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid. BMC Musculoskelet Disord 2020; 21:114. [PMID: 32085766 PMCID: PMC7035638 DOI: 10.1186/s12891-020-3135-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 02/12/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Several modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between cemented polyethylene glenoid (PEG) and three examples of modern MBG designs. METHODS Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into three groups based on follow-up duration: < 36-month, 36-72-month, and > 72-month subgroups. RESULTS This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21-93) and 66.5 years (31-88). The mean duration of follow-up was 73.1 (12-211) and 56.1 months (24-100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15%) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of < 36-month and 36-72-month subgroups showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P = 0.754 and 0.829, respectively). In the > 72-month subgroup, MBG was better in terms of loosening (P < 0.001) and failure rates (P = 0.006). CONCLUSIONS The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. Three modern MBG designs seem to have no difference in failure, at least in the < 36-month and 36-72-month subgroups compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted. LEVEL OF EVIDENCE Level IV, systematic review.
Collapse
Affiliation(s)
- Dong Min Kim
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | | | | | - Myung Jin Shin
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - Erica Kholinne
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea.,Department of Orthopaedic Surgery, St Carolus Hospital, Jakarta, Indonesia
| | - Hyojune Kim
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - In-Ho Jeon
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea
| | - Kyoung-Hwan Koh
- Department of Orthopaedic Surgery, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul, 05535, South Korea.
| |
Collapse
|
31
|
Prearthroplasty glenohumeral pathoanatomy and its relationship to patient's sex, age, diagnosis, and self-assessed shoulder comfort and function. J Shoulder Elbow Surg 2019; 28:2290-2300. [PMID: 31311749 DOI: 10.1016/j.jse.2019.04.043] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 04/02/2019] [Accepted: 04/15/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND There is great current interest in characterizing the prearthroplasty glenohumeral pathoanatomy because of its role in guiding surgical technique and its possible effects on arthroplasty outcome. METHODS We examined 544 patients within 6 weeks before arthroplasty with the goals of characterizing the following: demographic and radiographic characteristics; relationships of the radiographic pathoanatomy to the patient's age, sex, and diagnosis; inter-relationships among glenoid type, glenoid version, and amount of decentering of the humeral head on the glenoid; and relationships of the pathoanatomy to the patient's self-assessed comfort and function. RESULTS Male patients had a higher frequency of B2 glenoids and a lower frequency of A2 glenoids. The arthritic shoulders of men were more retroverted and had greater amounts of posterior decentering. Patients with types A1 and C glenoids were younger than those with other glenoid types. Shoulders with osteoarthritis were more likely to be type B2 and to be retroverted. Types B2 and C had the greatest degree of retroversion, whereas types B1 and B2 had the greatest amounts of posterior decentering. Shoulders with glenoid types B1 and B2 and those with more decentering did not have worse self-assessed shoulder comfort and function. CONCLUSIONS Glenohumeral pathoanatomy was found to have previously unreported relationships to the patient's sex, age, and diagnosis. Contrary to what might have been expected, more advanced glenohumeral pathoanatomy (ie, type B glenoids, greater retroversion, greater decentering) was not associated with worse self-assessed shoulder comfort and function.
Collapse
|
32
|
Denard PJ, Hsu JE, Whitson A, Neradilek MB, Matsen FA. Radiographic outcomes of impaction-grafted standard-length humeral components in total shoulder and ream-and-run arthroplasty: is stress shielding an issue? J Shoulder Elbow Surg 2019; 28:2181-2190. [PMID: 31272887 DOI: 10.1016/j.jse.2019.03.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/06/2019] [Accepted: 03/07/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to evaluate humeral stress shielding in shoulder arthroplasties performed with a smooth, standard-length humeral stem fixed with impaction autografting. METHODS Two-year outcomes were evaluated for 48 ream-and-run arthroplasties and 78 total shoulder arthroplasties (TSAs) performed at a single institution. Postoperative radiographs were analyzed for adaptive changes, calcar osteolysis, and component shift or subsidence. Radiographic outcomes were analyzed for associations with patient demographic characteristics, humeral stem filling ratios, and glenoid loosening; clinical outcomes were assessed using the Simple Shoulder Test. RESULTS At 2 years after surgery, the ream-and-run procedures showed partial calcar osteolysis in 9 cases (19%). The TSAs showed partial calcar osteolysis in 19 cases (24%) and complete calcar osteolysis in 2 (3%). Humeral component subsidence or component shift was observed in 3 ream-and-run procedures (6%) and in 8 TSAs (10%). These radiographic findings were not significantly associated with patient demographic characteristics, canal-filling ratios, or clinical outcomes. CONCLUSION When inserted with impaction autografting, a smooth, standard-length humeral stem offers a secure bone-preserving approach for humeral component fixation in shoulder arthroplasty. These results with a conventional prosthesis can serve as a basis for comparison for new component designs and fixation methods.
Collapse
Affiliation(s)
- Patrick J Denard
- Southern Oregon Orthopedics, Medford, OR, USA; Department of Orthopaedics & Rehabilitation, Oregon Health & Science University, Portland, OR, USA
| | - Jason E Hsu
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA
| | - Anastasia Whitson
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA
| | - Moni B Neradilek
- The Mountain-Whisper-Light Statistical Consulting, Seattle, WA, USA
| | - Frederick A Matsen
- Department of Orthopaedics and Sports Medicine, University of Washington, Seattle, WA, USA.
| |
Collapse
|
33
|
Alentorn-Geli E, Wanderman NR, Assenmacher AT, Sperling JW, Cofield RH, Sánchez-Sotelo J. Anatomic total shoulder arthroplasty with posterior capsular plication versus reverse shoulder arthroplasty in patients with biconcave glenoids: A matched cohort study. J Orthop Surg (Hong Kong) 2019; 26:2309499018768570. [PMID: 29661111 DOI: 10.1177/2309499018768570] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To compare the outcomes of total shoulder arthroplasty (TSA) with posterior capsule plication (PCP) and reverse shoulder arthroplasty (RSA) in patients with primary osteoarthritis, posterior subluxation, and bone loss (Walch B2). PATIENTS AND METHODS All shoulders undergoing anatomic TSA with PCP were retrospectively identified (group 1, G1) and compared to shoulders undergoing RSA (group 2, G2) for Walch B2 osteoarthritis. There were 15 patients in G1 (mean (SD) age and follow-up of 70.5 (7.5) years and 42.8 (18.4) months, respectively) and 16 patients in G2 (mean (SD) age and follow-up of 72.6 (5.4) years and 35.1 (14.2) months, respectively). RESULTS Both groups had substantial improvements in pain and function. In G1, results were excellent in 80% and satisfactory in 20%, compared to 81% and 6% in G2, respectively ( p = 0.2). The mean (SD) American Shoulder and Elbow Surgeons score was 91.2 (6.7) and 80.3 (14.3) in G1 and G2, respectively ( p = 0.08). The mean Simple Shoulder Test score was 10.6 in G1 and 8.5 in G2 ( p = 0.01). There were no reoperations in either group, but G1 had seven postoperative complications. CONCLUSIONS The outcomes of TSA with PCP are comparable to RSA in patients with osteoarthritis and biconcave glenoids. However, TSA leads to more complications while RSA leads to lower functional outcomes.
Collapse
Affiliation(s)
| | - Nathan R Wanderman
- Department of Orthopaedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | | | - John W Sperling
- Department of Orthopaedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Robert H Cofield
- Department of Orthopaedic Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | | |
Collapse
|
34
|
Alentorn-Geli E, Wanderman NR, Assenmacher AT, Sperling JW, Cofield RH, Sánchez-Sotelo J. Revision anatomic shoulder arthroplasty with posterior capsular plication for correction of posterior instability. J Orthop Surg (Hong Kong) 2019; 26:2309499018789527. [PMID: 30041574 DOI: 10.1177/2309499018789527] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Revision of failed anatomic total shoulder arthroplasty or hemiarthroplasty is a challenging procedure. Restoring adequate soft tissue balance in the revision setting can be particularly problematic. When persistent posterior instability is encountered in the revision setting, options include changing component position or size, posterior capsular plication (PCP), or conversion to a reverse arthroplasty. The purpose of this study was to report the clinical and radiographic outcomes, complications, and reoperations of PCP performed in the setting of revision anatomic shoulder arthroplasty. PATIENTS AND METHODS Between 1975 and 2013, 15 patients (16 shoulders) had PCP during revision anatomic shoulder arthroplasty. Indications for revision arthroplasty included posterior instability in 15, glenoid loosening in 3, polyethylene wear in 2, and glenoid erosion in 1 shoulder. The mean (standard deviation (SD)) age was 60.1 (12.6) years, and the median (range) follow-up was 68 (2-228) months. A retrospective chart review was conducted to obtain all data. RESULTS At the last follow-up, nine shoulders (56%) had absence of posterior radiographic subluxation. Five (31%) cases underwent reoperation due to persistent posterior instability. Complications were observed in seven (44%) cases. Complete pain relief was achieved in four (25%) shoulders. The mean (SD) postoperative forward flexion, external rotation, and the American Shoulder and Elbow Surgeons score were 110° (41°), 40° (29°), and 62.1 (21.9), respectively. Results were excellent in two (13%), satisfactory in seven (44%), and unsatisfactory in seven (44%) shoulders. CONCLUSIONS PCP to correct posterior instability during revision anatomic shoulder arthroplasty had an unacceptably high failure rate. In these circumstances, consideration should instead be given to conversion to a reverse shoulder arthroplasty.
Collapse
Affiliation(s)
| | | | | | - John W Sperling
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Robert H Cofield
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
35
|
Schoch BS, Wright TW, Zuckerman JD, Bolch C, Flurin PH, Roche C, King JJ. Glenoid component lucencies are associated with poorer patient-reported outcomes following anatomic shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:1956-1963. [PMID: 31202628 DOI: 10.1016/j.jse.2019.03.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 03/14/2019] [Accepted: 03/19/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND High rates of radiographic glenoid loosening following anatomic total shoulder arthroplasty (TSA) are documented at midterm follow-up. Small studies remain conflicted on the impact of lucent lines on clinical outcomes. This study assesses the impact of radiolucent lines on function and patient-reported outcomes (PROs) following TSA. METHODS We retrospectively evaluated 492 primary TSAs performed between February 2005 and April 2016. Radiographs were evaluated for glenoid loosening according to the Lazarus grade at a mean of 5.3 years (range, 2-12 years). Clinical outcome measures included range of motion and American Shoulder and Elbow Surgeons, Constant, University of California-Los Angeles, Simple Shoulder Test, and Shoulder Pain and Disability Index scores. Outcomes were compared between patients with and patients without glenoid lucent lines and in relation to lucency grade. RESULTS At most recent follow-up, 308 glenoids (63%) showed no radiolucent lines (group 0) and 184 demonstrated peri-glenoid lucencies (group 1). The groups were similar regarding age, sex, body mass index, comorbidities, and prior surgery. At follow-up, group 1 demonstrated significantly lower improvements in forward elevation (P = .02) and all PROs (P ≤ .005). Subgroup analysis by radiolucency grade showed that forward elevation diminished with increasing radiolucent score and exceeded the minimal clinically important difference (MCID) above grade 2 lucencies. A similar decline in PROs was observed with increasing lucency grade. These differences did not exceed the MCID below grade 5 lucencies. DISCUSSION Peri-implant glenoid lucencies following TSA are associated with lower forward elevation and PROs. Lucencies above grade 2 are associated with clinically important losses in overhead motion. However, differences below the MCID are maintained for PROs below grade 5 glenoid lucencies.
Collapse
Affiliation(s)
- Bradley S Schoch
- Department of Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA.
| | - Thomas W Wright
- Department of Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| | | | | | | | | | - Joseph J King
- Department of Orthopaedic Surgery and Rehabilitation, University of Florida, Gainesville, FL, USA
| |
Collapse
|
36
|
Uy M, Wang J, Horner NS, Bedi A, Leroux T, Alolabi B, Khan M. Cemented humeral stem versus press-fit humeral stem in total shoulder arthroplasty: a systematic review and meta-analysis. Bone Joint J 2019; 101-B:1107-1114. [PMID: 31474140 DOI: 10.1302/0301-620x.101b9.bjj-2018-1369.r1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
AIMS The aim of this study was to evaluate the differences in revision and complication rates, functional outcomes, and radiological outcomes between cemented and press-fit humeral stems in primary anatomical total shoulder arthroplasty (TSA). MATERIALS AND METHODS A comprehensive systematic review and meta-analysis was conducted searching for studies that included patients who underwent primary anatomical TSA for primary osteoarthritis or rheumatoid arthritis. RESULTS There was a total of 36 studies with 927 cemented humeral stems and 1555 press-fit stems. The revision rate was 5.4% (95% confidence interval (CI) 3.9 to 7.4) at a mean of 89 months for cemented stems, and 2.4% (95% CI 1.1 to 4.7) at a mean of 40 months for press-fit stems. A priori subgroup analysis to control for follow-up periods demonstrated similar revision rates: 2.3% (95% CI 1.1 to 4.7) for cemented stems versus 1.8% (95% CI 1.4 to 2.9) for press-fit stems. Exploratory meta-regression found that longer follow-up was a moderating variable for revision (p = 0.003). CONCLUSION Cement fixation had similar revision rates when compared to press-fit stems at short- to midterm follow-up. Rotator cuff pathology was a prevalent complication in both groups but is likely not related to fixation type. Overall, with comparable revision rates, possible easier revision, and decreased operative time, humeral press-fit fixation may be an optimal choice for primary anatomical TSA in patients with sufficient bone stock. Cite this article: Bone Joint J 2019;101-B:1107-1114.
Collapse
Affiliation(s)
- M Uy
- Michael G. DeGroote School of Medicine, McMaster University, Hamilton, Canada
| | - J Wang
- Michael G. DeGroote School of Medicine, McMaster University, Hamilton, Canada
| | - N S Horner
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, Canada
| | - A Bedi
- MedSport, University of Michigan, Ann Arbor, Michigan, USA
| | - T Leroux
- Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Canada
| | - B Alolabi
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, Canada
| | - M Khan
- Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, Canada
| |
Collapse
|
37
|
Welsher A, Gohal C, Madden K, Miller B, Bedi A, Alolabi B, Khan M. A comparison of pegged vs. keeled glenoid components regarding functional and radiographic outcomes in anatomic total shoulder arthroplasty: a systematic review and meta-analysis. JSES OPEN ACCESS 2019; 3:136-144.e1. [PMID: 31709353 PMCID: PMC6835032 DOI: 10.1016/j.jses.2019.04.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Background The number of total shoulder arthroplasties (TSAs) performed is increasing annually, with a continued effort to improve outcomes using new techniques and materials. In anatomic TSAs, the main options for glenoid fixation currently involve keeled or pegged components. The aim of this review was to determine which fixation option provides optimal long-term functional outcomes with decreased rates of revision surgery and radiolucency. Methods The MEDLINE, Embase, PubMed, and Cochrane databases were searched from 2007 to July 10, 2017, for all articles that examined TSAs using either pegged or keeled glenoid fixations. All studies were screened in duplicate for eligibility. Two separate analyses were completed examining noncomparative and comparative studies independently. Results A total of 7 comparative studies and 25 noncomparative studies were included in the final analysis. Included in the analysis were 4 randomized (level I) studies, 1 level II study, 8 level III studies, and 19 level IV studies. Meta-analysis of the comparative studies demonstrated a higher rate of revision surgery with keeled fixations compared with pegged fixations (odds ratio, 6.22; 95% confidence interval [CI], 1.38-28.1; P = .02). No significant difference was found with respect to functional outcomes, such as the American Shoulder and Elbow Surgeons score (mean difference, 9.54; 95% CI, –8.25 to 27.34; P = .29) and Constant score (mean difference, 5.31; 95% CI, –12.28 to 22.89; P = .55), as well as radiolucency rates (odds ratio, 1.89; 95% CI, 0.56−6.39; P = .30). Conclusion Pegged glenoid fixation may result in a decreased risk of revision TSAs, but no significant differences in patient-reported outcomes have been identified to date.
Collapse
Affiliation(s)
- Arthur Welsher
- Michael G. Degroote School of Medicine, McMaster University, Hamilton, ON, Canada
| | - Chetan Gohal
- Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
| | - Kim Madden
- Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
| | - Bruce Miller
- MedSport, University of Michigan, Ann Arbor, MI, USA
| | - Asheesh Bedi
- MedSport, University of Michigan, Ann Arbor, MI, USA
| | - Bashar Alolabi
- Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
| | - Moin Khan
- Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
- Corresponding author: Moin Khan, MD, MSc, St. Joseph's Healthcare Hamilton, 50 Charlton Ave E, Hamilton, ON L8N 4A6, Canada.
| |
Collapse
|
38
|
Castagna A, Garofalo R. Journey of the glenoid in anatomic total shoulder replacement. Shoulder Elbow 2019; 11:140-148. [PMID: 30936954 PMCID: PMC6434953 DOI: 10.1177/1758573218790119] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2018] [Accepted: 06/11/2018] [Indexed: 12/17/2022]
Abstract
Anatomic total shoulder arthroplasty (TSR) has been shown to generate good to excellent results for patients with osteoarthritis and a functioning rotator cuff. Many studies have reported that the glenoid component loosening and failure remain the most common long-term complication of total shoulder arthroplasty. The approach to glenoid component is critical because a surgeon should consider patient-specific anatomy, preserving bone stock and joint line restoration, for a good and durable shoulder function. Over the years, different glenoid design and materials have been tried in various configurations. These include cemented polyethylene, uncemented metal-backed and hybrid implants. Although advances in biomechanics, design and tribology have improved our understanding of the glenoid, the journey of the glenoid component in anatomic total shoulder arthroplasty has not yet reached its final destination. This article attempts to describe the evolution of the glenoid component in anatomic TSR and current practice.
Collapse
|
39
|
Szolomayer LK, Kuether J, Kassam HF, Mata Fink A, Regnell E, Kovacevic D, Blaine TA. Outcomes of Total Shoulder Arthroplasty With Posterior Capsular Plication. J Shoulder Elb Arthroplast 2019; 3:2471549218822389. [PMID: 34497941 PMCID: PMC8282147 DOI: 10.1177/2471549218822389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 12/09/2018] [Indexed: 11/17/2022] Open
Abstract
Background Glenoid loosening and instability are among the most common complications after anatomic total shoulder arthroplasty (TSA), resulting in poor function. Posterior instability is one contributing factor. The purpose of this study is to report the clinical and radiographic outcomes of a series of patients treated with posterior capsule plication for intraoperative posterior instability during TSA. It is hypothesized that patients undergoing this procedure will have improvement in posterior stability intraoperatively while not limiting their ROM postoperatively. Methods Patients of the senior author were identified who had undergone TSA with posterior capsule plication from 2014 to 2015 based on Current Procedural Terminology (CPT) codes. Their records and preoperative radiographs were retrospectively reviewed for demographic data and preoperative range of motion (ROM) which was documented in the clinic notes. Patients were then evaluated postoperatively to determine the outcomes after TSA with posterior capsule plication. Final follow-up was conducted via telephone survey. Results Nineteen patients were identified for review; however, only 14 had all imaging available. The mean age at the time of surgery was 63 years. There were 2 A1, 6 B1, and 6 B2 Walch-type glenoids based on preoperative imaging. All but one had equivalent or better ROM for active forward elevation and external rotation postoperatively. One patient required return to operating room at 5 months after developing adhesive capsulitis. Conclusion This study indicates that the use of posterior capsule plication during TSA is a safe method to address posterior subluxation, while still allowing for improved ROM postoperatively.
Collapse
Affiliation(s)
- Lauren K Szolomayer
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - Justin Kuether
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - Hafiz F Kassam
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - Ana Mata Fink
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - Elsa Regnell
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - David Kovacevic
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| | - Theodore A Blaine
- Department of Orthopedics and Rehabilitation, Yale Medical School, New Haven, Connecticut
| |
Collapse
|
40
|
One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers. INTERNATIONAL ORTHOPAEDICS 2018; 43:367-378. [DOI: 10.1007/s00264-018-4213-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Accepted: 10/23/2018] [Indexed: 11/30/2022]
|
41
|
Tashjian RZ, Chalmers PN. Future Frontiers in Shoulder Arthroplasty and the Management of Shoulder Osteoarthritis. Clin Sports Med 2018; 37:609-630. [DOI: 10.1016/j.csm.2018.05.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
42
|
Nelson CG, Brolin TJ, Ford MC, Smith RA, Azar FM, Throckmorton TW. Five-year minimum clinical and radiographic outcomes of total shoulder arthroplasty using a hybrid glenoid component with a central porous titanium post. J Shoulder Elbow Surg 2018. [PMID: 29526600 DOI: 10.1016/j.jse.2018.01.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND To determine the effectiveness of hybrid glenoid components in reducing the frequency of glenoid component loosening, we evaluated clinical and radiographic outcomes at a minimum 5-year follow-up in 45 shoulders that underwent total shoulder arthroplasty (TSA) using a system with a central porous titanium post to augment the cemented peripheral pegs. METHODS Function and pain were evaluated with the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment score, visual analog scale, active shoulder range of motion, and strength. Postoperative radiographs were analyzed for radiolucent lines, progressive loosening, and at-risk signs. RESULTS The mean American Shoulder and Elbow Surgeons score improved from 40.4 to 83.7 (P < .0001) and the mean visual analog scale from 5.9 to 0.8 (P < .0001). Forward elevation improved from 113° to 151° (P < .001), internal rotation from 49° to 60° (P = .035), and mean external rotation from 36° to 50° (P = .0006). Radiographs showed glenoid component radiolucency in 29 shoulders. Radiolucencies were confined to the area under the glenoid faceplate in 6 and were only around the central post in 13. Nine TSAs (20%) demonstrated 2 or more columns of involvement but were not judged to be at-risk. One implant (2.2%) had glenoid component failure and was revised to a hemiarthroplasty. CONCLUSION Anatomic TSA using a hybrid glenoid component with a central porous titanium post demonstrated a low rate of mechanical failure and a rate of radiolucent lines comparable to reports of all polyethylene implants. Further evaluations are needed to demonstrate the long-term durability of these implants and to determine the significance and fate of the radiolucent lines, particularly relative to the central post.
Collapse
Affiliation(s)
- Clay G Nelson
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA
| | - Tyler J Brolin
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA
| | - Marcus C Ford
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA
| | - Richard A Smith
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA
| | - Frederick M Azar
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA
| | - Thomas W Throckmorton
- Department of Orthopaedic Surgery & Biomedical Engineering, University of Tennessee-Campbell Clinic, Memphis, TN, USA.
| |
Collapse
|
43
|
Radiographic comparison of finned, cementless central pegged glenoid component and conventional cemented pegged glenoid component in total shoulder arthroplasty: a prospective randomized study. J Shoulder Elbow Surg 2018; 27:S10-S16. [PMID: 29246679 DOI: 10.1016/j.jse.2017.09.014] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Revised: 08/31/2017] [Accepted: 09/09/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Radiographic lucency of the glenoid component remains a problem after cement fixation in primary total shoulder arthroplasty. Glenoid component design likely contributes to rates of glenoid lucency. The purpose of this study was to prospectively compare radiographic lucency between a finned, cementless central pegged glenoid component (CL component) and a conventional cemented pegged glenoid component (P component) on immediate postoperative and minimum 2-year follow-up radiographs. METHODS Fifty-four patients undergoing total shoulder arthroplasty were prospectively randomized to receive an all-polyethylene CL component or a conventional all-polyethylene P component. Three raters graded glenoid lucency and bone interdigitation on immediate postoperative and latest follow-up radiographs. Patients who had undergone revision surgery or had died before evaluation were excluded. Minimum 2-year follow-up was required for inclusion of radiographic evaluation. RESULTS Fifty patients met inclusion criteria; 42 patients (84%; 20 CL and 22 P) were available for follow-up with the original glenoid implant in place. The mean follow-up duration was 35 months (24-64 months). There were no significant differences in glenoid radiolucency between CL (1/20 [5%]) and P (2/22 [9%]) components at last follow-up (P = .999). Five patients (25%) in the CL group had bone interdigitation. No instances of aseptic glenoid loosening occurred. CONCLUSION There were no significant differences in the rate of glenoid lucency between the 2 groups at immediate or an average 35-month follow-up. Both techniques appear to be viable options for initial glenoid component fixation, with CL components allowing possible osseointegration, imparting potential long-term stability.
Collapse
|
44
|
Raiss P, Godenèche A, Wittmann T, Schnetzke M, Bruckner T, Neyton L, Walch G. Short-term radiographic results of a cemented polyethylene keeled glenoid component with varying backside radiuses of curvature. J Shoulder Elbow Surg 2018; 27:839-845. [PMID: 29292036 DOI: 10.1016/j.jse.2017.10.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2017] [Revised: 10/09/2017] [Accepted: 10/18/2017] [Indexed: 02/07/2023]
Abstract
BACKGROUND This study analyzed the radiographic results of a cemented all-polyethylene keeled glenoid component available in different sizes and multiple backside radiuses of curvature. METHODS The study group consisted of 118 cases (114 patients). There were 63 women and 51 men. Mean age at the time of arthroplasty was 68 years (range, 51-85 years). True anterior-posterior radiographs obtained postoperatively and at the final follow-up were analyzed for implant seating and the occurrence of radiolucent lines. Glenoid morphology and fatty infiltration of the rotator cuff muscles were examined using computed tomography scans. Mean follow-up was 38 months (range, 24-70 months). RESULTS The mean radiolucent line score after surgery was 0.54 points (range, 0-3 points), and 90% had no or only 1 radiolucent line. At the final follow-up, the mean score was 1.06 points (range, 0-3 points), and 74% had no or only 1 radiolucent line. The score increased significantly over time (P < .001). No component was at risk for loosening. No correlation was found between patient age, sex, hand dominance, glenoid morphology, or fatty infiltration of the rotator cuff muscles and the occurrence of radiolucent lines. CONCLUSION In the short-term, the glenoid component analyzed in this study showed promising radiographic results, with a low number of radiolucent lines without failure. However, the mean radiolucent line score increased significantly over time, and long-term observations are necessary to confirm a possible advantage compared with older component designs.
Collapse
Affiliation(s)
- Patric Raiss
- Department for Shoulder and Elbow Surgery, Orthopädische Chirurgie München Clinic, Munich, Germany.
| | - Arnaud Godenèche
- Department for Shoulder Surgery, Centre Orthopédique Santy, Lyon, France
| | - Thomas Wittmann
- Department for Shoulder and Elbow Surgery, Orthopädische Chirurgie München Clinic, Munich, Germany
| | - Marc Schnetzke
- Department for Shoulder and Elbow Surgery, Berufsgenossenschaftliche Unfallklinik Ludwigshafen, Ludwigshafen, Germany
| | - Thomas Bruckner
- Institute of Medical Biometry and Informatics, University of Heidelberg, Heidelberg, Germany
| | - Lionel Neyton
- Department for Shoulder Surgery, Centre Orthopédique Santy, Lyon, France
| | - Gilles Walch
- Department for Shoulder Surgery, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
45
|
Van Vrekhem S, Vloebergh K, Asadian M, Vercruysse C, Declercq H, Van Tongel A, De Wilde L, De Geyter N, Morent R. Improving the surface properties of an UHMWPE shoulder implant with an atmospheric pressure plasma jet. Sci Rep 2018; 8:4720. [PMID: 29549270 PMCID: PMC5856771 DOI: 10.1038/s41598-018-22921-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 02/21/2018] [Indexed: 11/09/2022] Open
Abstract
Insufficient glenoid fixation is one of the main reasons for failure in total shoulder arthroplasty. This is predominantly caused by the inert nature of the ultra-high molecular weight polyethylene (UHMWPE) used in the glenoid component of the implant, which makes it difficult to adhesively bind to bone cement or bone. Previous studies have shown that this adhesion can be ameliorated by changing the surface chemistry using plasma technology. An atmospheric pressure plasma jet is used to treat UHMWPE substrates and to modify their surface chemistry. The modifications are investigated using several surface analysis techniques. The adhesion with bone cement is assessed using pull-out tests while osteoblast adhesion and proliferation is also tested making use of several cell viability assays. Additionally, the treated samples are put in simulated body fluid and the resulting calcium phosphate (CaP) deposition is evaluated as a measure of the in vitro bioactivity of the samples. The results show that the plasma modifications result in incorporation of oxygen in the surface, which leads to a significant improved adhesion to bone cement, an enhanced osteoblast proliferation and a more pronounced CaP deposition. The plasma-treated surfaces are therefore promising to act as a shoulder implant.
Collapse
Affiliation(s)
- S Van Vrekhem
- Research Unit Plasma Technology, Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Ghent, Belgium.
| | - K Vloebergh
- Research Unit Plasma Technology, Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Ghent, Belgium
| | - M Asadian
- Research Unit Plasma Technology, Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Ghent, Belgium
| | - C Vercruysse
- Tissue Engineering Group, Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Ghent University, De Pintelaan 185 6B3, 9000, Ghent, Belgium
| | - H Declercq
- Tissue Engineering Group, Department of Basic Medical Sciences, Faculty of Medicine and Health Sciences, Ghent University, De Pintelaan 185 6B3, 9000, Ghent, Belgium
| | - A Van Tongel
- Department of Orthopedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185 13K12, 9000, Ghent, Belgium
| | - L De Wilde
- Department of Orthopedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185 13K12, 9000, Ghent, Belgium
| | - N De Geyter
- Research Unit Plasma Technology, Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Ghent, Belgium
| | - R Morent
- Research Unit Plasma Technology, Department of Applied Physics, Faculty of Engineering and Architecture, Ghent University, Sint-Pietersnieuwstraat 41, B-9000, Ghent, Belgium
| |
Collapse
|
46
|
Dey R, Roche S, Rosch T, Mutsvangwa T, Charilaou J, Sivarasu S. Anatomic variations in glenohumeral joint: an interpopulation study. JSES OPEN ACCESS 2018; 2:1-7. [PMID: 30675559 PMCID: PMC6334885 DOI: 10.1016/j.jses.2017.11.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Background This study focused on the unique aspect of investigating shoulder morphometric differences between 2 distinct populations. Methods We used 90 computed tomography images of cadaveric shoulders for this study; 45 scans belonged to the South African (SA) cohort (49.74 ± 15.4 years) and the rest were Swiss (CH; 53.8 ± 21 years). The articulating surfaces of the glenohumeral joint were extracted, and their morphometric features, such as head circular diameter, glenoid and humeral head radius of curvature, head height, and humeral height, were measured. Results The mean interpopulation difference in the circular diameter of the humerus was 2.0 mm (P = .017) and 1.86 mm (P > .05) in the anterior-posterior and superior-inferior directions, respectively. The difference in the radius of curvature between the populations was 1.17 mm (P = .037). The SA shoulders were found to be longer than the CH shoulders by 8.4 mm (P > .05). There was no significant difference in the glenoid radius of curvature. The SA shoulders had higher glenohumeral mismatch (P = .005) and lower conformity index (P = .001) in comparison to the CH shoulders. Conclusion This study presents anatomic differences between African and European glenohumeral articulating surfaces. The results suggest that the glenohumeral geometry is both gender and population specific, and future joint replacements may be designed to address these differences.
Collapse
Affiliation(s)
- Roopam Dey
- Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | - Steven Roche
- Department of Orthopaedic Surgery, Groote Schuur Hospital, Cape Town, South Africa
| | - Theo Rosch
- Jakaranda Hospital, Pretoria, South Africa
| | - Tinashe Mutsvangwa
- Department of Human Biology, University of Cape Town, Cape Town, South Africa
| | - Johan Charilaou
- Department of Orthopaedic Surgery, Groote Schuur Hospital, Cape Town, South Africa
| | - Sudesh Sivarasu
- Department of Human Biology, University of Cape Town, Cape Town, South Africa
- Corresponding author: Sudesh Sivarasu, PhD, Department of Human Biology, UCT Medical Campus, 7.17, Anatomy Building, Anzio Road, Observatory, Cape Town 7935, South Africa. (S. Sivarasu).
| |
Collapse
|
47
|
Anatomic Total Shoulder Arthroplasty Using a Self-Pressurizing Pegged Bone-Preserving Cemented Glenoid Component: A 2- to 5-Year Follow-up Study. J Shoulder Elb Arthroplast 2018. [DOI: 10.1177/2471549217750478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Background: High rates of radiographic loosening have been reported with various glenoid designs. Many available designs sacrifice most of the bone at the central portion of the glenoid vault, creating large areas of deficiency when revision becomes necessary. The purpose of this study was to report the 2- to 5-year outcome of shoulder arthroplasty using a bone-preserving all-polyethylene glenoid components with self-pressurizing pegs. Methods: Between August 2011 and December 2014, 202 consecutive anatomic total shoulder arthroplasties (TSAs) were performed by a single surgeon with implantation of a self-pressurizing cemented pegged glenoid component in 190 patients (12 patients had both shoulders replaced). Patients were followed up prospectively and evaluated for pain, motion, strength, American Shoulder and Elbow Surgeons (ASES) scores, and radiographic changes. The mean follow-up time was 2.7 (2–5) years. Results: TSA improved pain and function reliably. At the most recent follow-up, 94% of the shoulders had no or mild pain. Motion included 154 ± 25° of elevation, 68 ± 18° of external rotation, and median internal rotation to T10 (range, iliac crest to T4). The most recent average ASES score was 82 ± 15 points. Early postoperative radiographs showed no radiolucent lines. No humeral or glenoid component was considered radiographically loose at the most recent follow-up. Complications requiring reoperation included subscapularis insufficiency (4), posterior instability (2), deep infection (1), stiffness (1), and a painful loose body (1). No components were revised for loosening. Conclusions: Anatomic TSA using a cemented bone-preserving all-polyethylene pegged self-pressurizing glenoid component provided satisfactory clinical outcomes and survival at 2 to 5 years.
Collapse
|
48
|
Kilian CM, Press CM, Smith KM, O'Connor DP, Morris BJ, Elkousy HA, Gartsman GM, Edwards TB. Radiographic and clinical comparison of pegged and keeled glenoid components using modern cementing techniques: midterm results of a prospective randomized study. J Shoulder Elbow Surg 2017; 26:2078-2085. [PMID: 28918112 DOI: 10.1016/j.jse.2017.07.016] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 06/29/2017] [Accepted: 07/14/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Glenoid component loosening remains a significant issue after anatomic shoulder arthroplasty. Pegged glenoid components have shown better lucency rates than keeled components in the short term; however, midterm to long-term results have not fully been determined. We previously reported early outcomes of the current randomized controlled group of patients, with higher glenoid lucency rates in those with a keeled glenoid. The purpose of this study was to evaluate the radiographic and clinical outcomes of these components at minimum 5-year follow-up. METHODS Fifty-nine total shoulder arthroplasties were performed in patients with primary glenohumeral osteoarthritis. Patients were randomized to receive either a pegged or keeled glenoid component. Three raters graded radiographic glenoid lucencies. Clinical outcome scores and active mobility outcomes were collected preoperatively and at yearly postoperative appointments. RESULTS Of the 46 shoulders meeting the inclusion criteria, 38 (82.6%) were available for minimum 5-year radiographic follow-up. After an average of 7.9 years, radiographic lucency was present in 100% of pegged and 91% of keeled components (P = .617). Grade 4 or 5 lucency was present in 44% of pegged and 36% of keeled components (P = .743). There were no differences in clinical outcome scores or active mobility outcomes between shoulders with pegged and keeled components at last follow-up. Within the initial cohort, 20% of the keeled shoulders (6 of 30) and 7% of the pegged shoulders (2 of 29) underwent revision surgery (P = .263). Kaplan-Meier analysis showed no significant difference in survival rates between groups (P = .560). CONCLUSION At an average 7.9-year follow-up, non-ingrowth, all-polyethylene pegged glenoid implants are equivalent to keeled implants with respect to radiolucency, clinical outcomes, and need for revision surgery.
Collapse
Affiliation(s)
| | - Cyrus M Press
- Nova Orthopaedic and Spine Care, Woodbridge, VA, USA
| | | | | | - Brent J Morris
- Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, TX, USA
| | - Hussein A Elkousy
- Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, TX, USA
| | - Gary M Gartsman
- Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, TX, USA
| | - T Bradley Edwards
- Fondren Orthopedic Group, Texas Orthopedic Hospital, Houston, TX, USA
| |
Collapse
|
49
|
Geraldes DM, Hansen U, Jeffers J, Amis AA. Stability of small pegs for cementless implant fixation. J Orthop Res 2017; 35:2765-2772. [PMID: 28387966 PMCID: PMC5763372 DOI: 10.1002/jor.23572] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2016] [Accepted: 04/03/2017] [Indexed: 02/04/2023]
Abstract
Most glenoid implants rely on large centrally located fixation features to avoid perforation of the glenoid vault in its peripheral regions. Upon revision of such components there may not be enough bone left for the reinsertion of an anatomical prosthesis. Multiple press-fit small pegs would allow for less bone resection and strong anchoring in the stiffer and denser peripheral subchondral bone. This study assessed the fixation characteristics, measured as the push-in (Pin ) and pull-out (Pout ) forces, and spring-back, measured as the elastic displacement immediately after insertion, for five different small press-fitted peg configurations manufactured out of UHMWPE cylinders (5 mm diameter and length). A total of 16 specimens for each configuration were tested in two types of solid bone substitute: Hard (40 PCF, 0.64 g/cm3 , worst-case scenario of Pin ) and soft (15 PCF, 0.24 g/cm3 , worst-case scenario of spring-back and Pout ). Two different diametric interference-fits were studied. Geometries with lower stiffness fins (large length to width aspect ratio) were the best performing designs in terms of primary fixation stability. They required the lowest force to fully seat, meaning they are less damaging to the bone during implantation, while providing the highest Pout /Pin ratio, indicating that when implanted they provide the strongest anchoring for the glenoid component. It is highlighted that drilling of chamfered holes could minimize spring-back displacements. These findings are relevant for the design of implants press-fitted pegs because primary fixation has been shown to be an important factor in achieving osseointegration and longevity of secondary fixation. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2765-2772, 2017.
Collapse
Affiliation(s)
- Diogo M. Geraldes
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonExhibition RoadSW7 2AZ LondonUnited Kingdom
| | - Ulrich Hansen
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonExhibition RoadSW7 2AZ LondonUnited Kingdom
| | - Jonathan Jeffers
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonExhibition RoadSW7 2AZ LondonUnited Kingdom
| | - Andrew A. Amis
- Biomechanics Group, Department of Mechanical EngineeringImperial College LondonExhibition RoadSW7 2AZ LondonUnited Kingdom,Musculoskeletal Surgery Group, Department of Surgery and CancerImperial College London School of MedicineW6 8RF LondonUnited Kingdom
| |
Collapse
|
50
|
Alentorn-Geli E, Clark NJ, Assenmacher AT, Samuelsen BT, Sánchez-Sotelo J, Cofield RH, Sperling JW. What Are the Complications, Survival, and Outcomes After Revision to Reverse Shoulder Arthroplasty in Patients Older Than 80 Years? Clin Orthop Relat Res 2017; 475:2744-2751. [PMID: 28699147 PMCID: PMC5638731 DOI: 10.1007/s11999-017-5406-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Accepted: 06/02/2017] [Indexed: 01/31/2023]
Abstract
BACKGROUND By the time patients with a failed shoulder arthroplasty require revision surgery, a substantial number are older than 80 years. The risk of complications of revision arthroplasty in this elderly population is largely unknown and needs to be considered when contemplating whether these patients are too frail for revision surgery. QUESTIONS/PURPOSES (1) What are the 90-day medical and surgical complications after revision to reverse shoulder arthroplasty (RSA) in patients older than 80 years? (2) What are the 2- and 5-year survival rates after revision? (3) Was there an improvement in pain at rest or with activity, range of motion (ROM), and strength after revision surgery? METHODS Between 2004 and 2013, 38 patients who were older than 80 years (84 ± 3 years) underwent revision surgery to a RSA. Of those, five were lost to followup before 2 years, and two had died within 2 years of revision surgery, leaving 31 for analysis of our survivorship, pain, ROM, and strength endpoints at a minimum of 2 years or until revision surgery had occurred (mean, 28 months; range, 1-77 months); all 38 patients were included for purposes of evaluating medical and surgical complications at 90 days. During the period in question, our general indication for using RSA included failure of previous shoulder arthroplasty because of instability, glenoid loosening with bone loss, or rotator cuff insufficiency. The indication for revision to RSA did not change during the study period. The index procedure (revision to RSA at the age of 80 years or older) was the first revision arthroplasty in 33 (87%) patients and the second in five (13%) patients. We tallied 90-day medical and surgical complications by performing a retrospective chart and institutional joint registry review. The cumulative incidence of implant loosening (implant migration or tilting, or complete radiolucent lines present) and revision surgery was calculated at 2 and 5 years using competing risk of death method. Pain levels at rest or with activity (rated in a 1 to 5 Likert-type scale) were collected through a retrospective chart review and values before and after surgery were compared. RESULTS Medical complications occurred in three of 38 (8%) patients and surgical complications occurred in five of 38 (13%) patients. The 90-day mortality was 3% (one of 38 patients), and the total mortality was 26% (10 of 38 patients). The cumulative incidence of revision was 11% (95% CI, 0%-20%) at 2 years and 16% (95% CI, 1%-30%) at 5 years; the cumulative incidence of loosening was 8% (95% CI, 0%-20%) at 2 years and 16% (95% CI, 1%-30%) at 5 years. Pain at rest or with activity improved from pre- to postoperation (preoperative: median, 4 [range, 2-5]; postoperative: median, 1 [range, 1-4]; median difference: -2, 95% CI -3 to 0; p < 0.000). The active ROM improved during the preoperative compared with postoperative periods: mean ± SD forward flexion of 52° ± 40° to 109° ± 44°, respectively (mean difference: 56; 95% CI, 40-72; p < 0.000), and mean ± SD external rotation of 15° ± 22° to 31° ± 21°, respectively (mean difference: 16; 95% CI, 8-25; p < 0.000). CONCLUSIONS Age should not be used as a reason to not consider revision surgery to RSA in patients older than 80 years. Further studies with a prospective design, larger sample size, investigating risk factors for complications or poor outcome, and incorporation of functional scores are required. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Eduard Alentorn-Geli
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Nicholas J Clark
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Andrew T Assenmacher
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Brian T Samuelsen
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Joaquín Sánchez-Sotelo
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Robert H Cofield
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - John W Sperling
- Department of Orthopaedic Surgery, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
| |
Collapse
|