• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4615257)   Today's Articles (1269)   Subscriber (49393)
For: Ibrahim H, Issa YM, Abu-Shawish HM. Chemically Modified Carbon Paste Electrode for the Potentiometric Determination of Dicylomine Hydrochloride in Batch and in FIA Conditions. ANAL SCI 2004;20:911-6. [PMID: 15228109 DOI: 10.2116/analsci.20.911] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Number Cited by Other Article(s)
1
Isildak Ö, Yildiz I, Genc N. A new potentiometric PVC membrane sensor for the determination of DPPH radical scavenging activity of plant extracts. Food Chem 2022;373:131420. [PMID: 34710684 DOI: 10.1016/j.foodchem.2021.131420] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 10/12/2021] [Accepted: 10/14/2021] [Indexed: 12/27/2022]
2
Özbek O, Berkel C, Isildak Ö. Applications of Potentiometric Sensors for the Determination of Drug Molecules in Biological Samples. Crit Rev Anal Chem 2020;52:768-779. [PMID: 32991203 DOI: 10.1080/10408347.2020.1825065] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
3
Madrakian T, Maleki S, Afkhami A. Application of a sensitive nanocomposite-based electrochemical sensor for voltammetric determination of dicyclomine hydrochloride in real samples. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2016. [DOI: 10.1007/s13738-016-0899-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
4
References. Anal Chem 2012. [DOI: 10.1201/b11478-14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
5
Khaled E, Hassan HNA, Mohamed GG, Seleim AEA. Towards disposable sensors for drug quality control: Dextromethorphan screen- printed electrodes. Drug Test Anal 2010;2:424-9. [DOI: 10.1002/dta.159] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
6
Carbon paste electrodes in the new millennium. OPEN CHEM 2009. [DOI: 10.2478/s11532-009-0097-9] [Citation(s) in RCA: 98] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]  Open
7
Coldur F, Andac M, Isildak I, Saka T. A micro-sized PVC membrane Li+-selective electrode without internal filling solution and its medical applications. J Electroanal Chem (Lausanne) 2009. [DOI: 10.1016/j.jelechem.2008.10.029] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
8
Girish Kumar K, Augustine P, John S, Radecki J, Radecka H. Fabrication of Potentiometric Sensors for the Selective Determination of Ketoconazole. ANAL LETT 2008. [DOI: 10.1080/00032710802051983] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
9
Abu-Shawish H. Potentiometric Response of Modified Carbon Paste Electrode Based on Mixed Ion-Exchangers. ELECTROANAL 2008. [DOI: 10.1002/elan.200704078] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
10
Vissers B, Bohets H, Everaert J, Cool P, Vansant E, Du Prez F, Kauffmann J, Nagels L. Characteristics of new composite- and classical potentiometric sensors for the determination of pharmaceutical drugs. Electrochim Acta 2006. [DOI: 10.1016/j.electacta.2006.03.040] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
11
Ibrahim H. Chemically modified carbon paste electrode for the potentiometric flow injection analysis of piribedil in pharmaceutical preparation and urine. J Pharm Biomed Anal 2005;38:624-32. [PMID: 15967290 DOI: 10.1016/j.jpba.2005.02.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2004] [Revised: 02/08/2005] [Accepted: 02/08/2005] [Indexed: 10/25/2022]
12
Ibrahim H. Carbon paste electrode modified with silver thimerosal for the potentiometric flow injection analysis of silver(I). Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.04.083] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
13
Issa YM, Abdel-Ghani NT, Shoukry AF, Ahmed HM. New Conventional Coated-Wire Ion-Selective Electrodes for Flow-Injection Potentiometric Determination of Chlordiazepoxide. ANAL SCI 2005;21:1037-42. [PMID: 16363470 DOI: 10.2116/analsci.21.1037] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA