1
|
Abd-Rabboh HSM, Amr AEGE, Naglah AM, Almehizia AA, Kamel AH. Effective screen-printed potentiometric devices modified with carbon nanotubes for the detection of chlorogenic acid: application to food quality monitoring. RSC Adv 2021; 11:38774-38781. [PMID: 35493243 PMCID: PMC9044248 DOI: 10.1039/d1ra08152g] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2021] [Accepted: 11/23/2021] [Indexed: 11/21/2022] Open
Abstract
All-solid state screen-printed electrodes were fabricated for chlorogenic acid (CGA) detection. The screen-printed platforms were modified with multi-walled carbon nanotubes (MWCNTs) to work as a lipophilic solid-contact transducer. The sensing-membrane was plasticized with a suitable solvent mediator and incorporating [NiII(bathophenanthroline)3][CGA]2 complex as a sensory material. In a 30 mM phosphate solution (buffer, pH 6), the sensor revealed a Nernstian-response towards CGA ions with a slope of -55.1 ± 1.1 (r 2 = 0.9997) over the linear range 1.0 × 10-7 to 1.0 × 10-3 (0.035-354.31 μg mL-1) with a detection limit 7.0 × 10-8 M (24.8 ng mL-1). It revealed a stable potentiometric response with excellent reproducibility and enhanced selectivity over several common ions. Short-term potential stability and the interfacial sensor capacitance was estimated using both electrochemical-impedance spectroscopy (EIS) and chronopotentiometry techniques. The presented electrochemical platform revealed the merits of design simplicity, ease of miniaturization, good potential-stability, and cost-effectiveness. It is successfully applied to CGA determination in different coffee beans extracts and juice samples. The data obtained were compared with those obtained by liquid chromatography reference method (HPLC).
Collapse
Affiliation(s)
- Hisham S M Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University Abha 61413 Saudi Arabia
- Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt
| | - Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, Drug Exploration and Development Chair (DEDC), College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia
- Applied Organic Chemistry Department, National Research Center 12622 Dokki Giza Egypt
| | - Ahmed M Naglah
- Pharmaceutical Chemistry Department, Drug Exploration and Development Chair (DEDC), College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia
| | - Abdulrahman A Almehizia
- Pharmaceutical Chemistry Department, Drug Exploration and Development Chair (DEDC), College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia
| | - Ayman H Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt
- Chemistry Department, College of Science Sakheer 32038 Kingdom of Bahrain
| |
Collapse
|
2
|
Abd-Rabboh HM, Amr AEGE, Almehizia AA, Kamel AH. Paper-Based Potentiometric Device for Rapid and Selective Determination of Salicylhydroxamate as a Urinary Struvite Stone Inhibitor. ACS OMEGA 2021; 6:27755-27762. [PMID: 34722975 PMCID: PMC8552353 DOI: 10.1021/acsomega.1c03135] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 09/29/2021] [Indexed: 05/28/2023]
Abstract
Novel paper-based potentiometric platforms for rapid, cost-effective, and simple determination of the salicylhydroxamic acid (SHAM) drug are presented. Both the SHAM sensor and the reference Ag/AgCl electrode were integrated together on the miniaturized paper platforms. The ion-sensing membrane for the presented sensor is based on the use of SnIV-tetraphenylporphyrin (SnIVTPP) as a charged carrier within a plasticized poly(vinyl chloride) (PVC) matrix. Multiwalled carbon nanotubes (MWCNTs) were used as an ion-to-electron transducer. The resulting sensor revealed a rapid and stable response with a Nernstian slope of -59.3 ± 0.7 mV/decade over the linear range of 1.0 × 10-6 to 1.0 × 10-3 M and a detection limit of 0.7 μM. All measurements were carried out in 30 mM phosphate-buffered solution (PBS) at pH 7.2. Intra- and interday precision were measured and found to be 1.7%. The relative standard deviation (RSD%) ( = 5) was calculated as 2.43% after utilizing five different electrodes (n = 5). The selectivity behavior of the prepared electrodes in the absence and presence of ionic additives was evaluated. The selectivity pattern showed a non-Hofmeister selectivity pattern in the existence of anionic additives with enhanced potentiometric selectivity for SHAM over different lipophilic anions (e.g., ClO4 -, SCN-, and I-). The presented device was successfully applied for SHAM determination in pharmaceutical preparations. This paper-based analytical device can be potentially manufactured at large scales and provides a portable, rapid, disposable, and cost-effective analytical tool for measuring the SHAM drug.
Collapse
Affiliation(s)
- Hisham
S. M. Abd-Rabboh
- Chemistry
Department, Faculty of Science, King Khalid
University, Abha 61413, Saudi Arabia
- Department
of Chemistry, Faculty of Science, Ain Shams
University, Cairo 11566, Egypt
| | - Abd El-Galil E. Amr
- Pharmaceutical
Chemistry Department, Drug Exploration & Development Chair (DEDC),
College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
- Applied
Organic Chemistry Department, National Research
Center, Dokki 12622, Giza, Egypt
| | - Abdulrahman A. Almehizia
- Pharmaceutical
Chemistry Department, Drug Exploration & Development Chair (DEDC),
College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Ayman H. Kamel
- Department
of Chemistry, Faculty of Science, Ain Shams
University, Cairo 11566, Egypt
- Chemistry
Department, College of Science, University
of Bahrain, Sakheer 32038, Kingdom of Bahrain
| |
Collapse
|
3
|
Kamel AH, Amr AEGE, Almehizia AA, Elsayed EA, Moustafa GO. Low-cost potentiometric paper-based analytical device based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for point-of-care copper(ii) determination. RSC Adv 2021; 11:27174-27182. [PMID: 35480650 PMCID: PMC9037668 DOI: 10.1039/d1ra04712d] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2021] [Accepted: 07/21/2021] [Indexed: 01/30/2023] Open
Abstract
A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination. All solid-state ion-selective electrodes (ISEs) for copper and a Ag/AgCl reference electrode were constructed and optimized on the paper substrate. The copper electrodes were built using carbon nano-tube ink as a conductive substrate and an ion-to electron transducer. A suitable polymeric membrane is drop-cast on the surface of the conductive carbon ink window. The copper-sensing membrane is based on newly synthesized macrocyclic pyrido-pentapeptide derivatives as novel ionophores for copper detection. Under the optimized conditions, the presented all-solid-state paper-based Cu2+-ISEs showed a Nernstian response toward Cu2+ ions in 30 mM MES buffer, pH 7.0 over the linear range of 5.0 × 10−7–1.0 × 10−3 M with a limit of detection of 8.0 × 10−8 M. The copper-based sensors exhibited rapid detection of Cu2+ ions with a short response time (<10 s). The selectivity pattern of these new ionophores towards Cu2+ ions over many common mono-, di- and trivalent cations was evaluated using the modified separate solution method (MSSM). The presented paper-based analytical device exhibited good intra-day and inter day precision. The presented tool was successfully applied for trace Cu2+ detection in real samples of serum and whole blood collected from different children with autism spectrum disorder. The data obtained by the proposed potentiometric method were compared with those obtained by the inductively-coupled plasma (ICP) as a reference method. The presented copper paper-based analytical-device can be considered as an attractive tool for point-of-care copper determination because of its affordability, vast availability, and self-pumping ability, particularly when combined with potentiometric detection. A simple, cost-effective, portable and disposable paper-based analytical device is designed and fabricated for copper(ii) determination.![]()
Collapse
Affiliation(s)
- Ayman H Kamel
- Chemistry Department, College of Science Sokheer 32038 Kingdom of Bahrain .,Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt
| | - Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia .,Applied Organic Chemistry Department, National Research Center Giza 12622 Egypt
| | - Abdulrahman A Almehizia
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia
| | - Elsayed A Elsayed
- Bioproducts Research Department, Zoology Department, Faculty of Science, King Saud University Riyadh 11451 Saudi Arabia .,Chemistry of Natural and Microbial Products Department, National Research Centre Dokki 12622 Cairo Egypt
| | - Gaber O Moustafa
- Department of Peptide Chemistry, National Research Centre Cairo Egypt
| |
Collapse
|
4
|
Amr AEGE, Kamel AH, Almehizia AA, Sayed AYA, Elsayed EA, Abd-Rabboh HSM. Paper-Based Potentiometric Sensors for Nicotine Determination in Smokers' Sweat. ACS OMEGA 2021; 6:11340-11347. [PMID: 34056289 PMCID: PMC8153920 DOI: 10.1021/acsomega.1c00301] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 04/09/2021] [Indexed: 06/01/2023]
Abstract
Herein, we describe for the first time, the design and fabrication of a novel nicotine paper-based sensor, in which a miniaturized paper reference electrode is integrated for potentiometric measurements. The paper-based sensors were designed using printed wax barriers to define the electrochemical cell and the sample zones. The electrodes were based on the use of the ion association complexes of the nicotinium cation (Nic) with either tetraphenylborate (TPB) or 5-nitrobarbiturate (NB) counter anions as sensing materials for nicotine recognition. A poly (3,4 ethylenedioxythiophene)/poly-(styrene sulfonate) (PEDOT/PSS) conducting polymer was used as an ion-to-electron transducer. The performance characteristics of the proposed sensors were evaluated and it revealed a rapid and stable response with a Nernstian slope of 55.2 ± 0.3 and 51.2 ± 0.6 mV/decade over the linear range of 1.0 × 10-5 to 1.0 × 10-2 M and detection limits of 6.0 and 8.0 μM for [Nic/TPB] and [Nic/NB], respectively. The sensors revealed a constant response over the pH range 3.5-6.5. The designed sensors provided a portable, inexpensive, and disposable way of measuring trace levels of nicotine coming from different cigarettes and in the collected human sweat of heavy smokers. All results were compared favorably with those obtained by the standard gas chromatographic method.
Collapse
Affiliation(s)
- Abd El-Galil E. Amr
- Pharmaceutical
Chemistry Department, Drug Exploration and Development Chair (DEDC),
College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
- Applied
Organic Chemistry Department, National Research
Center, Dokki, Giza 12622, Egypt
| | - Ayman H. Kamel
- Department
of Chemistry, Faculty of Science, Ain Shams
University, Cairo 11566, Egypt
| | - Abdulrahman A. Almehizia
- Pharmaceutical
Chemistry Department, Drug Exploration and Development Chair (DEDC),
College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Ahmed Y. A. Sayed
- Pharmaceutical
Chemistry Department, Drug Exploration and Development Chair (DEDC),
College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Elsayed A. Elsayed
- Zoology
Department, Faculty of Science, King Saud
University, Riyadh 11451, Saudi Arabia
- Chemistry
of Natural and Microbial Products Department, National Research Centre, Dokki, Cairo 12622, Egypt
| | | |
Collapse
|
5
|
Abd-Rabboh HSM, E. Amr AEG, Almehizia AA, Kamel AH. All-Solid-State Potentiometric Ion-Sensors Based on Tailored Imprinted Polymers for Pholcodine Determination. Polymers (Basel) 2021; 13:polym13081192. [PMID: 33917178 PMCID: PMC8067864 DOI: 10.3390/polym13081192] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/27/2021] [Accepted: 04/01/2021] [Indexed: 12/19/2022] Open
Abstract
In recent times, the application of the use of ion-selective electrodes has expanded in the field of pharmaceutical analyses due to their distinction from other sensors in their high selectivity and low cost of measurement, in addition to their high measurement sensitivity. Cost-effective, reliable, and robust all-solid-state potentiometric selective electrodes were designed, characterized, and successfully used for pholcodine determination. The design of the sensor device was based on the use of a screen-printed electrode modified with multiwalled carbon nanotubes (MWCNTs) as a solid-contact transducer. Tailored pholcodine (PHO) molecularly imprinted polymers (MIPs) were prepared, characterized, and used as sensory receptors in the presented potentiometric sensing devices. The sensors exhibited a sensitivity of 31.6 ± 0.5 mV/decade (n = 5, R2 = 0.9980) over the linear range of 5.5 × 10−6 M with a detection limit of 2.5 × 10−7 M. Real serum samples in addition to pharmaceutical formulations containing PHO were analyzed, and the results were compared with those obtained by the conventional standard liquid chromatographic approach. The presented analytical device showed an outstanding efficiency for fast, direct, and low-cost assessment of pholcodine levels in different matrices.
Collapse
Affiliation(s)
- Hisham S. M. Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University, Abha 61413, Saudi Arabia;
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
| | - Abd El-Galil E. Amr
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
- National Research Center, Applied Organic Chemistry Department, Dokki, Giza 12622, Egypt
- Correspondence: (A.E.-G.E.A.); (A.H.K.); Tel.: +966-565-148-750 (A.E.-G.E.A.); +20-1000361328 (A.H.K.)
| | - Abdulrahman A. Almehizia
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| | - Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Correspondence: (A.E.-G.E.A.); (A.H.K.); Tel.: +966-565-148-750 (A.E.-G.E.A.); +20-1000361328 (A.H.K.)
| |
Collapse
|
6
|
Amr AEGE, Kamel AH, Al-Omar MA, Elsayed EA, Sayed AYA, Abd-Rabboh HSM. An all-solid-state potentiometric sensor modified with multi-walled carbon nanotubes (MWCNTs) for silicate assessment and water-quality testing. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:1495-1501. [PMID: 33688881 DOI: 10.1039/d1ay00061f] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A simple and cost-effective approach is proposed for silicate ion determination. The approach is based on designing an all-solid-state potentiometric sensor. The plasticized polyvinyl chloride (PVC) membrane sensor is based on the ion-association complex [Ni(bphen)3]2+[SiO3]2- as a sensory recognition material. The sensor is modified with multi-walled carbon nanotubes (MWCNTs) as an ion-to-electron transducer material. The performance characteristics of the new silicate-selective electrode were evaluated using a potentiometric water-layer test, potentiometric measurements, impedance spectroscopy, and current-reversal chronopotentiometry. The developed electrodes exhibited a low detection limit (0.11 μg mL-1) over a wide linear range (4.0 × 10-6 to 1.0 × 10-3 M) and near-Nernstian sensitivity (slope = -28.1 ± 1.4 mV per decade). They presented a very short response time (<5 s) over the pH range 6-12 and provided acceptable reliability, ease of design and miniaturization, and high potential stability, in addition to good accuracy and precision. The sensors exhibited enhanced selectivity for silicate over many common interfering anions, such as SO42-, NO3-, CH3COO-, CO32-, Cl-, S2-, and PO43-. These results could qualify the developed sensor to be used in a successful way for the trace determination of silicate ions in different matrices. The developed method was successfully applied to the potentiometric detection of silicate in different pre-packaged bottled drinking water samples.
Collapse
Affiliation(s)
- Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
| | | | | | | | | | | |
Collapse
|
7
|
Abd-Rabboh HSM, Kamel AH, Alshehri FHA. Cacodylate Sensors and their Application in the Determination of Amino Acid Levels in Biological Samples. J AOAC Int 2021; 104:113-121. [PMID: 33751065 DOI: 10.1093/jaoacint/qsaa098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/07/2020] [Accepted: 07/08/2020] [Indexed: 11/14/2022]
Abstract
BACKGROUND The importance of recognizing and quantifying chemical anions/cations found in various types of samples, including environmental and biological samples, has been extensively studied. Recent findings suggest the possibility of health risks caused by organic compound dimethylarsinic acid (DMAs) rather than its inorganic arsenic metabolite. OBJECTIVE This article aims to fabricate polymeric-membrane electrochemical sensors with high sensitivity and selectivity for the cacodylic acid sodium salt dimethylarsinate (DMAs) based on silver diethyldithiocarbamate (AgDDTC) and CuIIphthalocyanine (CuPC) as novel neutral carriers and their applications. METHOD DMAs calibration relations and titrations were carried out using a potentiometric workstation equipped with a double-junction reference electrode, in conjunction with the fabricated working electrodes. RESULTS Sensors revealed fast and stable anionic response with near-Nernstian slopes (-38.6 ± 0.9 and -31.5 ± 0.6 mV/decade), within concentration ranges (1.7 × 10-5 -1.0 × 10-2 and 3.0 × 10-5 -1.0 × 10-2 M) and detection limits (1.0 × 10-5 and 1.6 × 10-5 M) for AgDDTC- and CuPC-based sensors, respectively. Sensors are characterized by extended life-time, signal stability, high precision and short response times. Selectivity for the cacodylate anion over most common anions was tested for the proposed electrodes. Sensors were satisfactorily applied for DMAs quantification in biological matrices with recoveries ranging between 96.2 and 99.0%. Membrane sensors were interfaced with a flow-through system for continuous monitoring of DMAs. The sensors were tested for the assay of different amino acids based on their reaction with cacodylate, where reaction end points were monitored with the proposed electrodes using direct potentiometric determination and flow injection analysis (FIA). CONCLUSIONS Potentiometric ion-selective PVC-membrane electrodes based on silver diethyldithiocarbamate (AgDDTC) and CuIIphthalothyanine (CuPC) provide adequate and reliable means for the determination of dimethylarsenate anion (cacodylate anion, DMAs). These membrane electrodes are easy to manufacture, they have the advantages of high selectivity and sensitivity, broad dynamic ranges, low detection limits, quick response times and cost effectiveness. Such properties make these sensors suitable for the assay of DMAs levels in aqueous solutions by direct potentiometry, flow injection and potentiometric titration, as well as in monitoring of the titration end points of the reactions between various amino acids and DMAs anion in aqueous solutions. HIGHLIGHTS Simple electrochemical membranes for dimethylarsinate (DMAs) were prepared, based on diethyldithiocarbamate (AgDDTC) and CuIIphthalocyanine (CuPC). - DMAs sensors were fabricated in two different modules: batch (for static) and flow-through (for hydrodynamic) approaches. - Levels of DMAs were determined in spiked biological samples. - AgDDTC-based sensors were successfully applied in the determination of several amino acids via potentiometric titration with DMAs.
Collapse
Affiliation(s)
- Hisham S M Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo 11566, Egypt
| | - Ayman H Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Abbassia, Cairo 11566, Egypt
| | - Fuziah H A Alshehri
- Chemistry Department, Faculty of Sciences and Arts, King Khalid University, P.O. Box 960, Mahayel Aseer 61421, Saudi Arabia
| |
Collapse
|
8
|
Abd-Rabboh HSM, Amr AEGE, Kamel AH, Al-Omar MA, Sayed AYA. Integrated all-solid-state sulfite sensors modified with two different ion-to-electron transducers: rapid assessment of sulfite in beverages. RSC Adv 2021; 11:3783-3791. [PMID: 35424314 PMCID: PMC8694217 DOI: 10.1039/d0ra09903a] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 05/13/2021] [Accepted: 01/10/2021] [Indexed: 11/21/2022] Open
Abstract
An integrated all-solid-state screen-printed ion-selective potentiometric sensor for rapid assessment of sulfite ion in beverages, based on analytical transduction, is described. The constructed potentiometric cell incorporates a polymeric membrane sulfite ion-selective electrode based on cobalt(ii) phthalocyanine (CoPC) as a recognition material and an Ag/AgCl reference electrode with a polyvinyl butyral reference membrane. Two different solid-contact transducers, namely multi-walled carbon nanotubes (MWCNTs) and polyaniline (PANI) were used for a comparative study. The presented sensors exhibited a rapid Nernst response across the concentration ranges from 2.0 × 10-6 to 2.3 × 10-3 M and from 5.0 × 10-6 to 2.3 × 10-3 M with detection limits equal to 1.1 × 10-6 M and 1.5 × 10-6 M for sensors based on MWCNTs and PANI, respectively. The proposed sensors manifested high selectivity and sensitivity, enhanced stability and low cost that provides a wide number of potential applications for food analysis. Good performance characteristics were obtained for the proposed method after applying the validation requirements. Method precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty are examined. These analytical capabilities support the rapid and direct determination of sulfite in different beverage samples. The analytical results were verified and compared with the standard iodometric method.
Collapse
Affiliation(s)
- Hisham S M Abd-Rabboh
- Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt +20-1000361328
- Chemistry Department, Faculty of Science, King Khalid University Abha 61413 Saudi Arabia
| | - Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia +966-565-148-750
- Applied Organic Chemistry Department, National Research Center Dokki 12622 Giza Egypt
| | - Ayman H Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University Cairo 11566 Egypt +20-1000361328
| | - Mohamed A Al-Omar
- Chemistry Department, Faculty of Science, King Khalid University Abha 61413 Saudi Arabia
| | - Ahmed Y A Sayed
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University Riyadh 11451 Saudi Arabia +966-565-148-750
| |
Collapse
|
9
|
Amr AEGE, Kamel AH, Almehizia AA, Sayed AYA, Abd-Rabboh HSM. Solid-Contact Potentiometric Sensors Based on Main-Tailored Bio-Mimics for Trace Detection of Harmine Hallucinogen in Urine Specimens. Molecules 2021; 26:molecules26020324. [PMID: 33435196 PMCID: PMC7826799 DOI: 10.3390/molecules26020324] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 01/06/2021] [Accepted: 01/07/2021] [Indexed: 11/21/2022] Open
Abstract
All-solid-state potentiometric sensors have attracted great attention over other types of potentiometric sensors due to their outstanding properties such as enhanced portability, simplicity of handling, affordability and flexibility. Herein, a novel solid-contact ion-selective electrode (SC-ISE) based on poly(3,4-ethylenedioxythiophene) (PEDOT) as the ion-to-electron transducer was designed and characterized for rapid detection of harmine. The harmine-sensing membrane was based on the use of synthesized imprinted bio-mimics as a selective material for this recognition. The imprinted receptors were synthesized using acrylamide (AA) and ethylene glycol dimethacrylate (EGDMA) as functional monomer and cross-linker, respectively. The polymerization process was carried out at 70 °C in the presence of dibenzoyl peroxide (DBO) as an initiator. The sensing membrane in addition to the solid-contact layer was applied to a glassy-carbon disc as an electronic conductor. All performance characteristics of the presented electrode in terms of linearity, detection limit, pH range, response time and selectivity were evaluated. The sensor revealed a wide linearity over the range 2.0 × 10−7–1.0 × 10−2 M, with a detection limit of 0.02 µg/mL and a sensitivity slope of 59.2 ± 0.8 mV/hamine concentration decade. A 40 mM Britton–Robinson (BR) buffer solution at pH of 6 was used for all harmine measurements. The electrode showed good selectivity towards harmine over other common interfering ions, and maintained a stable electrochemical response over two weeks. After applying the validation requirements, the proposed method revealed good performance characteristics. Method precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty were also evaluated. These analytical capabilities support the fast and direct assessment of harmine in different urine specimens. The analytical results were compared with the standard liquid chromatographic method. The results obtained demonstrated that PEDOT/PSS was a promising solid-contact ion-to-electron transducer material in the development of harmine-ISE. The electrodes manifested enhanced stability and low cost, which provides a wide number of potential applications for pharmaceutical and forensic analysis.
Collapse
Affiliation(s)
- Abde El-Galil E. Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Correspondence: (A.H.K.); (H.S.M.A.-R.); Tel.: +966-565-148-750 (H.S.M.A.-R.)
| | - Abdulrahman A. Almehizia
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Ahmed Y. A. Sayed
- Applied Organic Chemistry Department, National Research Center, Dokki, Giza 12622, Egypt; (A.A.A.); (A.Y.A.S.)
| | - Hisham S. M. Abd-Rabboh
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia
- Correspondence: (A.H.K.); (H.S.M.A.-R.); Tel.: +966-565-148-750 (H.S.M.A.-R.)
| |
Collapse
|
10
|
Screen-Printed Sensor Based on Potentiometric Transduction for Free Bilirubin Detection as a Biomarker for Hyperbilirubinemia Diagnosis. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8030086] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Novel reliable and cost-effective potentiometric screen-printed sensors for free bilirubin (BR) detection were presented. The sensors were fabricated using ordered mesoporous carbon (OMC) as an ion-to-electron transducer. The ion-association complex [Ni(bphen)3]2+[BR]2− was utilized as a sensory recognition material in the plasticized Polyvinyl Chloride (PVC) membrane. The membrane was drop-casted on the OMC layer, which is attached on a carbon conductor (2-mm diameter). In a 50 mM phosphate solution of pH 8.5, the electrodes offered a Nernstian slope of −26.8 ± 1.1 (r2 = 0.9997) mV/decade with a range of linearity 1.0 × 10−6–1 × 10−2 M towards free bilirubin with a detection limit 8.8 × 10−7 M (0.52 µg/mL). The presented sensors offered good features in terms of reliability, ease of design, high potential stability, high specificity and good accuracy and precision. Chronopotentiometric and electrochemical impedance spectrometric measurements were used for short-term potential stability and interfacial capacitance calculations. The sensors were used for the determination of free bilirubin in biological fluids. The data obtained are fairly well consistent with those obtained by the reference spectophotometric method. Based on the interaction of free BR with albumin (1:1), the sensors were also utilized for the assessment of albumin in human serum.
Collapse
|
11
|
Rapid and Accurate Validated Potentiometric Method for Bispyribac Herbicide Assessment in Rice and Agricultural Wastewater. WATER 2020. [DOI: 10.3390/w12082216] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
A new validated method based on potentiometric transduction for bispyribac herbicide assessment in commercial formulations, rice and wastewater samples is fabricated and characterized. Sensors are based in terms of their fabrication on tridodecyl methyl ammonium chloride (TDMAC) as recognition material. TDMAC was plasticized in a poly (vinyl chloride) (PVC) matrix to prepare the membrane. Under static modes of operation, the sensors revealed a Nernstian anionic slope of −63.6 ± 0.7 mV/decade within a linear range of 9.1 × 10−6–1.0 × 10−2 in 50 mM phosphate buffer solution (PBS), pH7. The detection limit was 6.0 × 10−6 M. The sensor was successfully introduced in a flow-stream system revealing a Nernstian response of −53.8 ± 1.3 mV/decade over a linear range of 2 × 10−4–1.0 × 10−2 M and lower detection limit of 5.6 × 10⁻⁵ M. The sampling rate was calculated to be (~42 sample/h). Validation of the assay method is presented in detail including accuracy, trueness, bias, between-day variability and within-day variability, and good performance characteristics of the method are obtained. The presented method was successfully introduced to bispyribac determination in different complex matrices such as commercial bispyribac sodium known as (Nominee-kz, 3% soluble liquid (SL)), rice samples and agricultural wastewater samples. The samples were analyzed successfully under both static and hydrodynamic modes of operation. The results obtained were in a good agreement with those obtained by the liquid chromatographic method.
Collapse
|
12
|
Kamel AH, Amr AEGE, Galal HR, Almehizia AA. Novel Validated Analytical Method Based on Potentiometric Transduction for the Determination of Citicoline Psychostimulant/Nootropic Agent. Molecules 2020; 25:molecules25153512. [PMID: 32752083 PMCID: PMC7435782 DOI: 10.3390/molecules25153512] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 07/29/2020] [Accepted: 07/31/2020] [Indexed: 11/29/2022] Open
Abstract
Herein, a novel validated potentiometric method is presented for the first time for citicoline determination. The method is based on measuring the potential using new constructed citicoline electrodes. The electrodes are based on the use of citicolinium/phosphomolybdate [Cit]2[PM] (sensor I) and citicolinium/tetraphenylborate [Cit][TPB] (sensor II) ion association complexes. These sensory materials were dispersed in plasticized polyvinyl chloride (PVC) polymeric membranes. The sensors revealed a Nernstian response with the slopes 55.9 ± 1.8(r2 = 0.9994) and 51.8 ± 0.9 (r2 = 0.9991) mV/decade over a linearity range of 6.3 × 10−6–1.0 × 10−3 and 1.0 × 10−5–1.0 × 10−3 M and detection limits of 3.16 × 10−6 and 7.1 × 10−6 M for sensors I and II, respectively. To ensure the existence of monovalent citicoline, all measurements were performed in 50 mM acetate buffer at pH 3.5. All presented electrodes showed good performance characteristics such as rapid response, good selectivity, high potential-stability and long life-span. Method verification and validation in terms of response linearity, quantification limit, accuracy, bias, trueness, robustness, within-day variability and between-days variability were evaluated. The method was introduced for citicoline determination in different pharmaceutical formulations and compared with the standard high performance liquid chromatography (HPLC) method.
Collapse
Affiliation(s)
- Ayman H. Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
- Correspondence: (A.H.K.); (A.E.-G.E.A.); Tel.: +20-100-074-3328 (A.H.K.); +966-565-148-750 (A.E.-G.E.A.)
| | - Abd El-Galil E. Amr
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
- Applied Organic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt
- Correspondence: (A.H.K.); (A.E.-G.E.A.); Tel.: +20-100-074-3328 (A.H.K.); +966-565-148-750 (A.E.-G.E.A.)
| | - Hoda R. Galal
- Inorganic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt;
| | - Abdulrahman A. Almehizia
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia;
| |
Collapse
|
13
|
Liquid Contact-Selective Potentiometric Sensor Based on Imprinted Polymeric Beads Towards 17β-Estradiol Determination. Polymers (Basel) 2020; 12:polym12071506. [PMID: 32645900 PMCID: PMC7407799 DOI: 10.3390/polym12071506] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 06/26/2020] [Accepted: 07/02/2020] [Indexed: 11/18/2022] Open
Abstract
Novel potentiometric devices “ion-selective electrodes (ISEs)” were designed and characterized for the detection of 17β-estradiol (EST) hormone. The selective membranes were based on the use of man-tailored biomimics (i.e., molecularly imprinted polymers (MIPs)) as recognition ionophores. The synthesized MIPs include a functional monomer (methacrylic acid (MAA)) and a cross-linker (ethylene glycol dimethacrylic acid (EGDMA)) in their preparation. Changes in the membrane potential induced by the dissociated 17β-estradiol were investigated in 50 mM CO32−/HCO3− buffer solution at pH 10.5. The ion-selective electrodes (ISEs) exhibited fast response and good sensitivity towards 17β-estradiol with a limit of detection 1.5 µM over a linear range starts from 2.5 µM with an anionic response of 61.2 ± 1.2 mV/decade. The selectivity pattern of the proposed ISEs was also evaluated and revealed an enhanced selectivity towards EST over several phenolic compounds. Advantages revealed by the presented sensor (i.e., wide range of assay, enhanced accuracy and precision, low limit of detection, good selectivity, long-term potential stability, rapid response and long life-span and absence of any sample pretreatment steps) suggest its use in routine quality control/quality assurance tests. They were successfully applied to estradiol determination in biological fluids and in different pharmaceutical preparations collected from the local market.
Collapse
|
14
|
Hassan SSM, H Kamel A, Amr AEGE, Abd-Rabboh HSM, Al-Omar MA, Elsayed EA. A New Validated Potentiometric Method for Sulfite Assay in Beverages Using Cobalt(II) Phthalocyanine as a Sensory Recognition Element. Molecules 2020; 25:E3076. [PMID: 32640703 PMCID: PMC7412148 DOI: 10.3390/molecules25133076] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/01/2020] [Accepted: 07/02/2020] [Indexed: 11/20/2022] Open
Abstract
A simple potentiometric sensor is described for accurate, precise, and rapid determination of sulfite additives in beverages. The sensor is based on the use of cobalt phthalocyanine as a recognition material, dispersed in a plasticized poly(vinyl chloride) matrix membrane. o-Nitrophenyl octyl ether (o-NPOE) as a membrane solvent and tri-dodecylmethyl- ammonium chloride (TDMAC) as ion discriminators are used as membrane additives. Under the optimized conditions, sulfite ion is accurately and precisely measured under batch and flow injection modes of analysis. The sensor exhibits fast and linear response for 1.0 × 10-2-1.0 × 10-6 M (800-0.08 µg/mL) and 1.0 × 10-1-5.0 × 10-5 M (8000-4 µg/mL) sulfite with Nernstian slopes of -27.4 ± 0.3 and -23.7 ± 0.6 mV/concentration decade under static and hydrodynamic modes of operation, respectively. Results in good agreement with the standard iodometric method are obtained.Validation of the assay method is examined in details including precision, accuracy, bias, trueness, repeatability, reproducibility, and uncertainty and good performance characteristics of the method are obtained. The sensor response is stable over the pH range of 5 to 7 without any significant interference from most common anions. The advantages offered by the proposed sensor (i.e., wide range of assay, high accuracy and precision, low detection limit, reasonable selectivity, long term response stability, fast response, and long life span and absence of any sample pretreatment steps) suggest its use in the quality control/quality assurance routine tests in beverages industries, toxicological laboratories and by inspection authorities.
Collapse
Affiliation(s)
- Saad S M Hassan
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
| | - Ayman H Kamel
- Department of Chemistry, Faculty of Science, Ain Shams University, Cairo 11566, Egypt
| | - Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
- Applied Organic Chemistry Department, National Research Center, Dokki 12622, Giza, Egypt
| | - Hisham S M Abd-Rabboh
- Chemistry Department, Faculty of Science, King Khalid University, P.O. Box 9004, Abha 61413, Saudi Arabia
| | - Mohamed A Al-Omar
- Pharmaceutical Chemistry Department, College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
| | - Elsayed A Elsayed
- Zoology Department, Faculty of Science, King Saud University, Riyadh 11451, Saudi Arabia
- Chemistry of Natural and Microbial Products Department, National Research Centre, Dokki 12622, Cairo, Egypt
| |
Collapse
|
15
|
Solid-Contact Potentiometric Sensors Based on Stimulus-Responsive Imprinted Polymers for Reversible Detection of Neutral Dopamine. Polymers (Basel) 2020; 12:polym12061406. [PMID: 32585949 PMCID: PMC7362186 DOI: 10.3390/polym12061406] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 06/13/2020] [Accepted: 06/17/2020] [Indexed: 12/21/2022] Open
Abstract
Herein, we present for the first time a novel potentiometric sensor based on the stimulus-responsive molecularly imprinted polymer (MIP) as a selective receptor for neutral dopamine determination. This smart receptor can change its capabilities to recognize according to external environmental stimuli. Therefore, MIP-binding sites can be regenerated in the polymeric membrane by stimulating with stimulus after each measurement. Based on this effect, reversible detection of the analyte via potentiometric transduction can be achieved. MIPs based on 4-vinylphenylboronic acid as the functional monomer were prepared as the selective receptor. This monomer can successfully bind to dopamine via covalent binding and forming a five- or six-membered cyclic ester in a weakly alkaline aqueous solution. In acidic medium, the produced ester dissociates and regenerates new binding sites in the polymeric membrane. The proposed smart sensor exhibited fast response and good sensitivity towards dopamine with a limit of detection 0.15 µM over the linear range 0.2–10 µM. The selectivity pattern of the proposed ISEs was also evaluated and revealed an enhanced selectivity towards dopamine over several phenolic compounds. Constant-current chronopotentiometry is used for evaluating the short-term potential stability of the proposed ISEs. The obtained results confirm that the stimulus-responsive MIPs provide an attractive way towards reversible MIP-based electrochemical sensors designation.
Collapse
|
16
|
Modified Potentiometric Screen-Printed Electrodes Based on Imprinting Character for Sodium Deoxycholate Determination. Biomolecules 2020; 10:biom10020251. [PMID: 32041305 PMCID: PMC7072443 DOI: 10.3390/biom10020251] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2020] [Revised: 02/04/2020] [Accepted: 02/04/2020] [Indexed: 11/16/2022] Open
Abstract
Potentiometric sensors have a great influence on the determination of most various compounds in their matrices. Therefore, efficient and new sensors were introduced to measure sodium Deoxycholate (NaDC) as a bile acid salt. These sensors are based on NaDC imprinted polymer (MIP) as sensory element. The MIP beads were synthesized using thermal polymerization pathway, in which acrylamide (AAm), ethylene glycol dimethacrylate (EGDMA), NaDC, and benzoyl peroxide (BPO) were used as the functional monomer, cross-linker, template, and initiator, respectively. The proposed sensors were fabricated using a coated screen-printed platform and the sensing membrane was modified by single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer. The sensors exhibited high sensitivity that reached 4.7 × 10−5 M of near-Nernestian slope (−60.1 ± 0.9 mV/decade, r2 = 0.999 (n= 5)). In addition, the sensors revealed high selectivity, long lifetime, high potential stability, and conductivity that ensure reproducible and accurate results over a long time. MIP characterization was performed using Fourier Transform-Infrared (FT-IR) and a scanning electron microscope (SEM). Regarding the interaction of NaDC with serum albumin (SA), albumin is determined in human serum samples as human serum albumin (HSA), which was collected from different volunteers of different ages and gender.
Collapse
|
17
|
S M Hassan S, E Amr AEG, Abd El-Naby H, A Al-Omar M, H Kamel A, Khalifa NM. Potentiometric PVC-Membrane-Based Sensor for Dimethylamine Assessment Using A Molecularly Imprinted Polymer as A Sensory Recognition Element. Polymers (Basel) 2019; 11:polym11101695. [PMID: 31623171 PMCID: PMC6836042 DOI: 10.3390/polym11101695] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2019] [Revised: 09/30/2019] [Accepted: 10/11/2019] [Indexed: 11/16/2022] Open
Abstract
A new simple potentiometric sensor is developed and presented for sensitive and selective monitoring of dimethylamine (DMA). The sensor incorporates a molecularly imprinted polymer, with a pre-defined specific cavity suitable to accommodate DMA. The molecularly imprinted polymer (MIP) particles were dispersed in an aplasticized poly(vinyl chloride) matrix. The MIP is synthesized by using a template molecule (DMA), a functional monomer (acrylamide, AM), cross-linker (ethylene glycol dimethacrylate, EGDMA) and initiating reagent (benzoylperoxide, BPO). Using Trizma buffer solution (5 mmol L-1, pH 7.1), the sensor exhibits a rapid, stable and linear response for 1.0 × 10-5 to 1.0 × 10-2 mol L-1 DMA+ with a calibration slope of 51.3 ± 0.3 mV decade-1, and a detection limit of 4.6 × 10-6 mol L-1 (0.37 µg mL-1). The electrode exhibited a short response time (10 s) and stable potential readings (± 0.5 mV) for more than 2 months. Potentiometric selectivity measurements of the sensor reveal negligible interferences from most common aliphatic and aromatic amines. High concentration levels (100-fold excess) of many inorganic cations do not interfere. The sensor is successfully used for quantification of low levels of DMA down to 0.5 µg mL-1. Verification of the presented method was carried out after measuring the detection limit, working linearity range, ruggedness of the method, accuracy, precision, repeatability and reproducibility. Under flow-through conditions, the proposed sensor in its tubular form is prepared and introduced in a two-channel flow injection setup for hydrodynamic determination of DMA. The sampling rate is 50-55 samples h-1. The sensor is used to determine DMA in different soil samples with an accuracy range of 97.0-102.8%.
Collapse
Affiliation(s)
- Saad S M Hassan
- Chemistry Department, Faculty of Science, Ain Shams University, 11566 Abbasia, Cairo, Egypt.
| | - Abd El-Galil E Amr
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
- Applied Organic Chemistry Department, National Research Centre, 12622 Dokki, Giza, Egypt.
| | - Heba Abd El-Naby
- Chemistry Department, Faculty of Science, Ain Shams University, 11566 Abbasia, Cairo, Egypt.
| | - Mohamed A Al-Omar
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
| | - Ayman H Kamel
- Chemistry Department, Faculty of Science, Ain Shams University, 11566 Abbasia, Cairo, Egypt.
| | - Nagy M Khalifa
- Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia.
- Applied Organic Chemistry Department, National Research Centre, 12622 Dokki, Giza, Egypt.
| |
Collapse
|
18
|
Single-Walled Carbon Nanotubes (SWCNTs) as Solid-Contact in All-Solid-State Perchlorate ISEs: Applications to Fireworks and Propellants Analysis. SENSORS 2019; 19:s19122697. [PMID: 31208022 PMCID: PMC6630701 DOI: 10.3390/s19122697] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 06/09/2019] [Accepted: 06/11/2019] [Indexed: 12/02/2022]
Abstract
Herein, we present reliable, robust, stable, and cost-effective solid-contact ion-selective electrodes (ISEs) for perchlorate determination. Single-walled carbon nanotubes (SWCNTs) were used as solid-contact material and indium (III) 5, 10, 15, 20-(tetraphenyl) porphyrin chloride (InIII-porph) as an ion carrier. The sensor exhibited an improved sensitivity towards ClO4− ions with anionic slope of −56.0 ± 1.1 (R2 = 0.9998) mV/decade over a linear range 1.07 × 10−6 – 1.0 × 10−2 M and detection limit of 1.8 × 10−7 M. The short-term potential stability and the double-layer capacitance were measured by chronopotentiometric and electrochemical impedance spectroscopy (EIS) measurements, respectively. The sensor is used for ClO4− determination in fireworks and propellant powders. The results fairly agree with data obtained by ion chromatography.
Collapse
|
19
|
Ilea A, Andrei V, Feurdean CN, Băbțan AM, Petrescu NB, Câmpian RS, Boșca AB, Ciui B, Tertiș M, Săndulescu R, Cristea C. Saliva, a Magic Biofluid Available for Multilevel Assessment and a Mirror of General Health-A Systematic Review. BIOSENSORS-BASEL 2019; 9:bios9010027. [PMID: 30769890 PMCID: PMC6468816 DOI: 10.3390/bios9010027] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Revised: 02/01/2019] [Accepted: 02/09/2019] [Indexed: 02/07/2023]
Abstract
Background: Saliva has been recently proposed as an alternative to classic biofluid analyses due to both availability and reliability regarding the evaluation of various biomarkers. Biosensors have been designed for the assessment of a wide spectrum of compounds, aiding in the screening, diagnosis, and monitoring of pathologies and treatment efficiency. This literature review aims to present the development in the biosensors research and their utility using salivary assessment. Methods: a comprehensive literature search has been conducted in the PubMed database, using the keywords “saliva” and “sensor”. A two-step paper selection algorithm was devised and applied. Results: The 49 papers selected for the present review focused on assessing the salivary biomarkers used in general diseases, oral pathologies, and pharmacology. The biosensors proved to be reliable tools for measuring the salivary levels of biochemical metabolic compounds such as glucose, proteinases and proteins, heavy metals and various chemical compounds, microorganisms, oncology markers, drugs, and neurotransmitters. Conclusions: Saliva is a biofluid with a significant clinical applicability for the evaluation and monitoring of a patient’s general health. Biosensors designed for assessing a wide range of salivary biomarkers are emerging as promising diagnostic or screening tools for improving the patients’ quality of life.
Collapse
Affiliation(s)
- Aranka Ilea
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Vlad Andrei
- DMD, Rezident doctor in Periodontology, Clinical County Hospital, 540136 Târgu Mureș, Romania.
| | - Claudia Nicoleta Feurdean
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Anida-Maria Băbțan
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Nausica Bianca Petrescu
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Radu Septimiu Câmpian
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Oral Rehabilitation, Oral Health and Dental Office Management, Faculty of Dentistry, 400012 Cluj-Napoca, Romania.
| | - Adina Bianca Boșca
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Histology, Faculty of Medicine, 400349 Cluj, Romania.
| | - Bianca Ciui
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Mihaela Tertiș
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Robert Săndulescu
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| | - Cecilia Cristea
- Iuliu Haţieganu" University of Medicine and Pharmacy Cluj-Napoca, Department of Analytical Chemistry, Faculty of Pharmacy, 400349 Cluj, Romania.
| |
Collapse
|
20
|
Potentiometric Anion Selectivity and Analytical Applications of Polymer Membrane Electrodes Based on Novel Mn(III)- and Mn(IV)-Salophen Complexes. ELECTROANAL 2016. [DOI: 10.1002/elan.201600335] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
21
|
TOSSANAITADA B, MASADOME T, IMATO T. Sequential Injection Analysis of Thiocyanate Ions Using a Microfluidic Polymer Chip with an Embedded Ion-Selective Electrode. ANAL SCI 2014; 30:507-11. [DOI: 10.2116/analsci.30.507] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Benjaporn TOSSANAITADA
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Takashi MASADOME
- Department of Applied Chemistry, Faculty of Engineering, Shibaura Institute of Technology
| | - Toshihiko IMATO
- Department of Applied Chemistry, Graduate School of Engineering, Kyushu University
| |
Collapse
|
22
|
Opportunities and challenges of using ion-selective electrodes in environmental monitoring and wearable sensors. Electrochim Acta 2012. [DOI: 10.1016/j.electacta.2012.04.147] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
23
|
Vinnakota CV, Peetha NS, Perrizo MG, Ferris DG, Oda RP, Rockwood GA, Logue BA. Comparison of cyanide exposure markers in the biofluids of smokers and non-smokers. Biomarkers 2012; 17:625-33. [PMID: 22889346 DOI: 10.3109/1354750x.2012.709880] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Cyanide is highly toxic and is present in many foods, combustion products (e.g. cigarette smoke), industrial processes, and has been used as a terrorist weapon. In this study, cyanide and its major metabolites, thiocyanate and 2-amino-2-thiazoline-4-carboxylic acid (ATCA), were analyzed from various human biofluids of smokers (low-level chronic cyanide exposure group) and non-smokers to gain insight into the relationship of these biomarkers to cyanide exposure. The concentrations of each biomarker tested were elevated for smokers in each biofluid. Significant differences (p < 0.05) were found for thiocyanate in plasma and urine, and ATCA showed significant differences in plasma and saliva. Additionally, biomarker concentration ratios, correlations between markers of cyanide exposure, and other statistical methods were performed to better understand the relationship between cyanide and its metabolites. Of the markers studied, the results indicate plasma ATCA, in particular, showed excellent promise as a biomarker for chronic low-level cyanide exposure.
Collapse
Affiliation(s)
- Chakravarthy V Vinnakota
- Department of Chemistry and Biochemistry, South Dakota State University, Brookings, SD 57007, USA
| | | | | | | | | | | | | |
Collapse
|
24
|
Youso SL, Rockwood GA, Logue BA. The analysis of protein-bound thiocyanate in plasma of smokers and non-smokers as a marker of cyanide exposure. J Anal Toxicol 2012; 36:265-9. [PMID: 22474215 PMCID: PMC3523951 DOI: 10.1093/jat/bks017] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
When cyanide is introduced into the body, it quickly transforms through a variety of chemical reactions, normally involving sulfur donors, to form more stable chemical species. Depending on the nature of the sulfur donor, cyanide may be transformed into free thiocyanate, the major metabolite of cyanide transformation, 2-amino-2-thiazoline-4-carboxylic acid or protein-bound thiocyanate (PB-SCN) adducts. Because protein adducts are generally stable in biological systems, it has been suggested that PB-SCN may have distinct advantages as a marker of cyanide exposure. In this study, plasma was analyzed from 25 smokers (chronic low-level cyanide exposure group) and 25 non-smokers for PB-SCN. The amount of PB-SCN found in the plasma of smokers, 1.35 µM, was significantly elevated (p < 0.0001) when compared to non-smokers, 0.66 µM. Differences in sub-groups of smokers and non-smokers were also evaluated. The results of this study indicate the effectiveness of analyzing PB-SCN in determining instances of chronic cyanide exposure with possible extension to confirmation of acute cyanide exposure.
Collapse
Affiliation(s)
- Stephanie L. Youso
- Department of Chemistry and Biochemistry, South Dakota State University, Brookings, SD 57007
| | - Gary A. Rockwood
- US Army Medical Research Institute of Chemical Defense, Analytical Toxicology Division, 3100 Ricketts Point Road, Aberdeen Proving Ground, MD 21010-5400
| | - Brian A. Logue
- Department of Chemistry and Biochemistry, South Dakota State University, Brookings, SD 57007
| |
Collapse
|
25
|
Capillary ion electrophoresis of inorganic anions and uric acid in human saliva using a polyvinyl alcohol coated capillary column and hexamethonium chloride as additive of background electrolyte. J Chromatogr B Analyt Technol Biomed Life Sci 2012; 887-888:1-7. [DOI: 10.1016/j.jchromb.2011.12.027] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 12/29/2011] [Accepted: 12/29/2011] [Indexed: 11/22/2022]
|
26
|
Aglan RF, Mohamed GG, Mohamed HA. Chemically Modified Carbon Paste Electrode for Determination of Cesium Ion by Potentiometric Method. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/ajac.2012.38076] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
27
|
Logue BA, Hinkens DM, Baskin SI, Rockwood GA. The Analysis of Cyanide and its Breakdown Products in Biological Samples. Crit Rev Anal Chem 2010. [DOI: 10.1080/10408340903535315] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|