1
|
Riccardi M, Martin OJF. Electromagnetic Forces and Torques: From Dielectrophoresis to Optical Tweezers. Chem Rev 2023; 123:1680-1711. [PMID: 36719985 PMCID: PMC9951227 DOI: 10.1021/acs.chemrev.2c00576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Indexed: 02/02/2023]
Abstract
Electromagnetic forces and torques enable many key technologies, including optical tweezers or dielectrophoresis. Interestingly, both techniques rely on the same physical process: the interaction of an oscillating electric field with a particle of matter. This work provides a unified framework to understand this interaction both when considering fields oscillating at low frequencies─dielectrophoresis─and high frequencies─optical tweezers. We draw useful parallels between these two techniques, discuss the different and often unstated assumptions they are based upon, and illustrate key applications in the fields of physical and analytical chemistry, biosensing, and colloidal science.
Collapse
Affiliation(s)
- Marco Riccardi
- Nanophotonics and Metrology Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), EPFL-STI-NAM, Station 11, CH-1015Lausanne, Switzerland
| | - Olivier J. F. Martin
- Nanophotonics and Metrology Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), EPFL-STI-NAM, Station 11, CH-1015Lausanne, Switzerland
| |
Collapse
|
2
|
Wu Y, Fu A, Yossifon G. Active Particle Based Selective Transport and Release of Cell Organelles and Mechanical Probing of a Single Nucleus. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2020; 16:e1906682. [PMID: 32363783 DOI: 10.1002/smll.201906682] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 03/27/2020] [Accepted: 03/27/2020] [Indexed: 06/11/2023]
Abstract
Self-propelling micromotors are emerging as a promising microscale tool for single-cell analysis. The authors have recently shown that the field gradients necessary to manipulate matter via dielectrophoresis can be induced at the surface of a polarizable active ("self-propelling") metallo-dielectric Janus particle (JP) under an externally applied electric field, acting essentially as a mobile floating microelectrode. Here, the application of the mobile floating microelectrode to trap and transport cell organelles in a selective and releasable manner is successfully extended. This selectivity is driven by the different dielectrophoretic (DEP) potential wells on the JP surface that is controlled by the frequency of the electric field, along with the hydrodynamic shearing and size of the trapped organelles. Such selective and directed loading enables purification of targeted organelles of interest from a mixed biological sample while their dynamic release enables their harvesting for further analysis such as gene/RNA sequencing or proteomics. Moreover, the electro-deformation of the trapped nucleus is shown to be in correlation with the DEP force and hence, can act as a promising label-free biomechanical marker. Hence, the active carrier constitutes an important and novel ex vivo platform for manipulation and mechanical probing of subcellular components of potential for single cell analysis.
Collapse
Affiliation(s)
- Yue Wu
- Faculty of Mechanical Engineering, Micro- and Nano-Fluidics Laboratory, Technion-Israel Institute of Technology, Haifa, 32000, Israel
| | - Afu Fu
- Technion Integrated Cancer Center, The Rappaport Faculty of Medicine and Research Institute, Technion-Israel Institute of Technology, Haifa, 3525433, Israel
| | - Gilad Yossifon
- Faculty of Mechanical Engineering, Micro- and Nano-Fluidics Laboratory, Technion-Israel Institute of Technology, Haifa, 32000, Israel
| |
Collapse
|
3
|
Separation, Characterization, and Handling of Microalgae by Dielectrophoresis. Microorganisms 2020; 8:microorganisms8040540. [PMID: 32283664 PMCID: PMC7232385 DOI: 10.3390/microorganisms8040540] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 04/01/2020] [Accepted: 04/05/2020] [Indexed: 12/19/2022] Open
Abstract
Microalgae biotechnology has a high potential for sustainable bioproduction of diverse high-value biomolecules. Some of the main bottlenecks in cell-based bioproduction, and more specifically in microalgae-based bioproduction, are due to insufficient methods for rapid and efficient cell characterization, which contributes to having only a few industrially established microalgal species in commercial use. Dielectrophoresis-based microfluidic devices have been long established as promising tools for label-free handling, characterization, and separation of broad ranges of cells. The technique is based on differences in dielectric properties and sizes, which results in different degrees of cell movement under an applied inhomogeneous electrical field. The method has also earned interest for separating microalgae based on their intrinsic properties, since their dielectric properties may significantly change during bioproduction, in particular for lipid-producing species. Here, we provide a comprehensive review of dielectrophoresis-based microfluidic devices that are used for handling, characterization, and separation of microalgae. Additionally, we provide a perspective on related areas of research in cell-based bioproduction that can benefit from dielectrophoresis-based microdevices. This work provides key information that will be useful for microalgae researchers to decide whether dielectrophoresis and which method is most suitable for their particular application.
Collapse
|
4
|
Affiliation(s)
- Daihyun Kim
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Mukul Sonker
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| | - Alexandra Ros
- School of Molecular Sciences, Arizona State University, Tempe, Arizona 85287, United States
- Center for Applied Structural Discovery, The Biodesign Institute, Arizona State University, Tempe, Arizona 85287, United States
| |
Collapse
|
5
|
Frusawa H. Frequency-Modulated Wave Dielectrophoresis of Vesicles And Cells: Periodic U-Turns at the Crossover Frequency. NANOSCALE RESEARCH LETTERS 2018; 13:169. [PMID: 29881976 PMCID: PMC5991112 DOI: 10.1186/s11671-018-2583-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 05/24/2018] [Indexed: 05/25/2023]
Abstract
We have formulated the dielectrophoretic force exerted on micro/nanoparticles upon the application of frequency-modulated (FM) electric fields. By adjusting the frequency range of an FM wave to cover the crossover frequency f X in the real part of the Clausius-Mossotti factor, our theory predicts the reversal of the dielectrophoretic force each time the instantaneous frequency periodically traverses f X . In fact, we observed periodic U-turns of vesicles, leukemia cells, and red blood cells that undergo FM wave dielectrophoresis (FM-DEP). It is also suggested by our theory that the video tracking of the U-turns due to FM-DEP is available for the agile and accurate measurement of f X . The FM-DEP method requires a short duration, less than 30 s, while applying the FM wave to observe several U-turns, and the agility in measuring f X is of much use for not only salty cell suspensions but also nanoparticles because the electric-field-induced solvent flow is suppressed as much as possible. The accuracy of f X has been verified using two types of experiment. First, we measured the attractive force exerted on a single vesicle experiencing alternating-current dielectrophoresis (AC-DEP) at various frequencies of sinusoidal electric fields. The frequency dependence of the dielectrophoretic force yields f X as a characteristic frequency at which the force vanishes. Comparing the AC-DEP result of f X with that obtained from the FM-DEP method, both results of f X were found to coincide with each other. Second, we investigated the conductivity dependencies of f X for three kinds of cell by changing the surrounding electrolytes. From the experimental results, we evaluated simultaneously both of the cytoplasmic conductivities and the membrane capacitances using an elaborate theory on the single-shell model of biological cells. While the cytoplasmic conductivities, similar for these cells, were slightly lower than the range of previous reports, the membrane capacitances obtained were in good agreement with those previously reported in the literature.
Collapse
Affiliation(s)
- Hiroshi Frusawa
- School of Environmental Science & EngineeringKochi University of Technology, Tosa-Yamada, Kochi, 782-8502, Japan.
| |
Collapse
|
6
|
Probing Contaminant-Induced Alterations in Chlorophyll Fluorescence by AC-Dielectrophoresis-Based 2D-Algal Array. BIOSENSORS-BASEL 2018; 8:bios8010015. [PMID: 29439453 PMCID: PMC5872063 DOI: 10.3390/bios8010015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 01/28/2018] [Accepted: 02/07/2018] [Indexed: 11/17/2022]
Abstract
The investigation of contaminant impact on algae requires rapid and reliable cell collection and optical detection. The capability of alternative current (AC) dielectrophoresis (DEP) collection of whole cell arrays with combined fluorescence microscopy detection to follow the alterations of chlorophyll fluorescence during environmental contaminant exposure was explored. The application of an AC-field of 100 V cm-1, 100 Hz for 30 min to capture and immobilize the cells of green alga Chlamydomonas reinhardtii in two-dimensional (2D) arrays does not induce changes in chlorophyll fluorescence. The results demonstrate that DEP-based 2D-arrays allow non-invasive detection of chlorophyll fluorescence change upon exposure to high concentrations of copper oxide nanoparticles and ionic copper. These results were in agreement with data obtained by flow cytometry used as a comparative method. The tool was also applied to follow the effect of a number of ubiquitous contaminants such as inorganic mercury, methylmercury, and diuron. However, a statistically significant short-term effect was observed only for mercury. Overall, DEP-based 2D-arrays of algal cells with fluorescence detection appear to be suitable for stain-free probing the effects on the photosynthetic microorganisms in highly polluted environment.
Collapse
|
7
|
Podgorny OV, Lazarev VN. Laser microdissection: A promising tool for exploring microorganisms and their interactions with hosts. J Microbiol Methods 2017; 138:82-92. [PMID: 26775287 DOI: 10.1016/j.mimet.2016.01.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2015] [Revised: 11/11/2015] [Accepted: 01/01/2016] [Indexed: 12/14/2022]
Abstract
Laser microdissection is a method that allows for the isolation of homogenous cell populations from their native niches in tissues for downstream molecular assays. This method is widely used for genomic analysis, gene expression profiling and proteomic and metabolite assays in various fields of biology, but it remains an uncommon approach in microbiological research. In spite of the limited number of publications, laser microdissection was shown to be an extremely useful method for studying host-microorganism interactions in animals and plants, investigating bacteria within biofilms, identifying uncultivated bacteria and performing single prokaryotic cell analysis. The current paper describes the methodological aspects of commercially available laser microdissection instruments and representative examples that demonstrate the advantages of this method for resolving a variety of issues in microbiology.
Collapse
Affiliation(s)
- Oleg V Podgorny
- Federal Research and Clinical Center of Physical-Chemical Medicine of Federal Medical Biological Agency, 1a Malaya Pirogovskaya Str., Moscow 119435, Russia; Koltzov Institute of Developmental Biology of the Russian Academy of Sciences, 26 Vavilov Str., Moscow 119334, Russia.
| | - Vassili N Lazarev
- Federal Research and Clinical Center of Physical-Chemical Medicine of Federal Medical Biological Agency, 1a Malaya Pirogovskaya Str., Moscow 119435, Russia
| |
Collapse
|
8
|
Huang L, Tu L, Zeng X, Mi L, Li X, Wang W. Study of a Microfluidic Chip Integrating Single Cell Trap and 3D Stable Rotation Manipulation. MICROMACHINES 2016; 7:E141. [PMID: 30404313 PMCID: PMC6190350 DOI: 10.3390/mi7080141] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2016] [Revised: 08/01/2016] [Accepted: 08/05/2016] [Indexed: 12/15/2022]
Abstract
Single cell manipulation technology has been widely applied in biological fields, such as cell injection/enucleation, cell physiological measurement, and cell imaging. Recently, a biochip platform with a novel configuration of electrodes for cell 3D rotation has been successfully developed by generating rotating electric fields. However, the rotation platform still has two major shortcomings that need to be improved. The primary problem is that there is no on-chip module to facilitate the placement of a single cell into the rotation chamber, which causes very low efficiency in experiment to manually pipette single 10-micron-scale cells into rotation position. Secondly, the cell in the chamber may suffer from unstable rotation, which includes gravity-induced sinking down to the chamber bottom or electric-force-induced on-plane movement. To solve the two problems, in this paper we propose a new microfluidic chip with manipulation capabilities of single cell trap and single cell 3D stable rotation, both on one chip. The new microfluidic chip consists of two parts. The top capture part is based on the least flow resistance principle and is used to capture a single cell and to transport it to the rotation chamber. The bottom rotation part is based on dielectrophoresis (DEP) and is used to 3D rotate the single cell in the rotation chamber with enhanced stability. The two parts are aligned and bonded together to form closed channels for microfluidic handling. Using COMSOL simulation and preliminary experiments, we have verified, in principle, the concept of on-chip single cell traps and 3D stable rotation, and identified key parameters for chip structures, microfluidic handling, and electrode configurations. The work has laid a solid foundation for on-going chip fabrication and experiment validation.
Collapse
Affiliation(s)
- Liang Huang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| | - Long Tu
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| | - Xueyong Zeng
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| | - Lu Mi
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| | - Xuzhou Li
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| | - Wenhui Wang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, China.
| |
Collapse
|
9
|
Liu AP. Biophysical Tools for Cellular and Subcellular Mechanical Actuation of Cell Signaling. Biophys J 2016; 111:1112-1118. [PMID: 27456131 DOI: 10.1016/j.bpj.2016.02.043] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2015] [Revised: 01/17/2016] [Accepted: 02/01/2016] [Indexed: 10/24/2022] Open
Abstract
The ability to spatially control cell signaling can help resolve fundamental biological questions. Optogenetic and chemical dimerization techniques along with fluorescent biosensors to report cell signaling activities have enabled researchers to both visualize and perturb biochemistry in living cells. A number of approaches based on mechanical actuation using force-field gradients have emerged as complementary technologies to manipulate cell signaling in real time. This review covers several technologies, including optical, magnetic, and acoustic control of cell signaling and behavior and highlights some studies that have led to novel insights. I will also discuss some future direction on repurposing mechanosensitive channel for mechanical actuation of spatial cell signaling.
Collapse
Affiliation(s)
- Allen P Liu
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan; Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan; Cellular and Molecular Biology Program, University of Michigan, Ann Arbor, Michigan; Biophysics Program, University of Michigan, Ann Arbor, Michigan.
| |
Collapse
|
10
|
Lownes Urbano R, Morss Clyne A. An inverted dielectrophoretic device for analysis of attached single cell mechanics. LAB ON A CHIP 2016; 16:561-73. [PMID: 26738543 PMCID: PMC4734981 DOI: 10.1039/c5lc01297j] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Dielectrophoresis (DEP), the force induced on a polarizable body by a non-uniform electric field, has been widely used to manipulate single cells in suspension and analyze their stiffness. However, most cell types do not naturally exist in suspension but instead require attachment to the tissue extracellular matrix in vivo. Cells alter their cytoskeletal structure when they attach to a substrate, which impacts cell stiffness. It is therefore critical to be able to measure mechanical properties of cells attached to a substrate. We present a novel inverted quadrupole dielectrophoretic device capable of measuring changes in the mechanics of single cells attached to a micropatterned polyacrylamide gel. The device is positioned over a cell of defined size, a directed DEP pushing force is applied, and cell centroid displacement is dynamically measured by optical microscopy. Using this device, single endothelial cells showed greater centroid displacement in response to applied DEP pushing force following actin cytoskeleton disruption by cytochalasin D. In addition, transformed mammary epithelial cell (MCF10A-NeuT) showed greater centroid displacement in response to applied DEP pushing force compared to untransformed cells (MCF10A). DEP device measurements were confirmed by showing that the cells with greater centroid displacement also had a lower elastic modulus by atomic force microscopy. The current study demonstrates that an inverted DEP device can determine changes in single attached cell mechanics on varied substrates.
Collapse
Affiliation(s)
- Rebecca Lownes Urbano
- Drexel University, Department of Mechanical Engineering and Mechanics, 3141 Chestnut Street, Philadelphia, PA 19104, USA.
| | - Alisa Morss Clyne
- Drexel University, Department of Mechanical Engineering and Mechanics, 3141 Chestnut Street, Philadelphia, PA 19104, USA.
| |
Collapse
|
11
|
TANAKA T, MIZUTANI F, YASUKAWA T. Dielectrophoretic Tweezers for Pickup and Relocation of Individual Cells Using Microdisk Electrodes with a Microcavity. ELECTROCHEMISTRY 2016. [DOI: 10.5796/electrochemistry.84.361] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Taishu TANAKA
- Graduate School of Material Science, University of Hyogo
| | - Fumio MIZUTANI
- Graduate School of Material Science, University of Hyogo
| | | |
Collapse
|
12
|
Md Ali MA, Ostrikov K(K, Khalid FA, Majlis BY, Kayani AA. Active bioparticle manipulation in microfluidic systems. RSC Adv 2016. [DOI: 10.1039/c6ra20080j] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
Abstract
The motion of bioparticles in a microfluidic environment can be actively controlled using several tuneable mechanisms, including hydrodynamic, electrophoresis, dielectrophoresis, magnetophoresis, acoustophoresis, thermophoresis and optical forces.
Collapse
Affiliation(s)
- Mohd Anuar Md Ali
- Institute of Microengineering and Nanoelectronics
- Universiti Kebangsaan Malaysia
- Bangi
- Malaysia
| | - Kostya (Ken) Ostrikov
- School of Chemistry, Physics, and Mechanical Engineering
- Queensland University of Technology
- Brisbane
- Australia
- CSIRO-QUT Joint Sustainable Processes and Devices Laboratory
| | - Fararishah Abdul Khalid
- Faculty of Technology Management and Technopreneurship
- Universiti Teknikal Malaysia Melaka
- Malaysia
| | - Burhanuddin Y. Majlis
- Institute of Microengineering and Nanoelectronics
- Universiti Kebangsaan Malaysia
- Bangi
- Malaysia
| | - Aminuddin A. Kayani
- Institute of Microengineering and Nanoelectronics
- Universiti Kebangsaan Malaysia
- Bangi
- Malaysia
- Center for Advanced Materials and Green Technology
| |
Collapse
|
13
|
Siebman C, Velev OD, Slaveykova VI. Two-Dimensional Algal Collection and Assembly by Combining AC-Dielectrophoresis with Fluorescence Detection for Contaminant-Induced Oxidative Stress Sensing. BIOSENSORS 2015; 5:319-36. [PMID: 26083806 PMCID: PMC4493552 DOI: 10.3390/bios5020319] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Revised: 05/31/2015] [Accepted: 06/05/2015] [Indexed: 12/23/2022]
Abstract
An alternative current (AC) dielectrophoretic lab-on-chip setup was evaluated as a rapid tool of capture and assembly of microalga Chlamydomonas reinhardtii in two-dimensional (2D) close-packed arrays. An electric field of 100 V·cm⁻¹, 100 Hz applied for 30 min was found optimal to collect and assemble the algae into single-layer structures of closely packed cells without inducing cellular oxidative stress. Combined with oxidative stress specific staining and fluorescence microscopy detection, the capability of using the 2D whole-cell assembly on-chip to follow the reactive oxygen species (ROS) production and oxidative stress during short-term exposure to several environmental contaminants, including mercury, methylmercury, copper, copper oxide nanoparticles (CuO-NPs), and diuron was explored. The results showed significant increase of the cellular ROS when C. reinhardtii was exposed to high concentrations of methylmercury, CuO-NPs, and 10⁻⁵ M Cu. Overall, this study demonstrates the potential of combining AC-dielectrophoretically assembled two-dimensional algal structures with cell metabolic analysis using fluorescence staining, as a rapid analytical tool for probing the effect of contaminants in highly impacted environment.
Collapse
Affiliation(s)
- Coralie Siebman
- Environmental Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10 route de Suisse, Versoix CH-1290, Switzerland.
| | - Orlin D Velev
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | - Vera I Slaveykova
- Environmental Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10 route de Suisse, Versoix CH-1290, Switzerland.
| |
Collapse
|
14
|
Song Y, Sonnenberg A, Heaney Y, Heller MJ. Device for dielectrophoretic separation and collection of nanoparticles and DNA under high conductance conditions. Electrophoresis 2015; 36:1107-14. [DOI: 10.1002/elps.201400507] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 02/07/2015] [Accepted: 02/19/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Youngjun Song
- Department of Electrical and Computer Engineering; University of California San Diego; La Jolla CA USA
| | - Avery Sonnenberg
- Department of Bioengineering; University of California San Diego; La Jolla CA USA
| | - Yvonne Heaney
- Department of NanoEngineering; University of California San Diego; La Jolla CA USA
| | - Michael J. Heller
- Department of Bioengineering; University of California San Diego; La Jolla CA USA
- Department of NanoEngineering; University of California San Diego; La Jolla CA USA
| |
Collapse
|
15
|
Guillaume-Gentil O, Zambelli T, Vorholt JA. Isolation of single mammalian cells from adherent cultures by fluidic force microscopy. LAB ON A CHIP 2014; 14:402-14. [PMID: 24270585 DOI: 10.1039/c3lc51174j] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The physical separation of individual cells from cell populations for single-cell analysis and proliferation is of wide interest in biology and medicine. Today, single-cell isolation is routinely applied to non-adherent cells, though its application to cells grown on a substrate remains challenging. In this report, a versatile approach for isolating single HeLa cells directly from their culture dish is presented. Fluidic force microscopy is first used to detach the targeted cell(s) via the tunable delivery of trypsin, thereby achieving cellular detachment with single-cell resolution. The cell is then trapped by the microfluidic probe via gentle aspiration, displaced with micrometric precision and either transferred onto a new substrate or deposited into a microwell. An optimised non-fouling coating ensures fully reversible cell capture and the potential for serial isolation of multiple cells with 100% successful transfer rate (n = 130) and a survival rate of greater than 95%. By providing an efficient means for isolating targeted adherent cells, the described approach offers exciting possibilities for biomedical research.
Collapse
Affiliation(s)
- Orane Guillaume-Gentil
- ETH Zurich, Institute of Microbiology, Wolfgang-Pauli-Strasse 10, 8093 Zurich, Switzerland.
| | | | | |
Collapse
|
16
|
Tang SY, Zhang W, Baratchi S, Nasabi M, Kalantar-zadeh K, Khoshmanesh K. Modifying Dielectrophoretic Response of Nonviable Yeast Cells by Ionic Surfactant Treatment. Anal Chem 2013; 85:6364-71. [DOI: 10.1021/ac400741v] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Affiliation(s)
- Shi-Yang Tang
- School of Electrical and Computer
Engineering, RMIT University, VIC 3001,
Australia
| | - Wei Zhang
- School of Electrical and Computer
Engineering, RMIT University, VIC 3001,
Australia
| | - Sara Baratchi
- School of Electrical and Computer
Engineering, RMIT University, VIC 3001,
Australia
- Health Innovations
Research
Institute, RMIT University, VIC 3083, Australia
| | - Mahyar Nasabi
- School of Electrical and Computer
Engineering, RMIT University, VIC 3001,
Australia
| | | | | |
Collapse
|
17
|
Abstract
In this paper, we introduce a dielectrophoresis (DEP)-based handling method that allows fine 3D manipulation of beads in suspension using a lab on a chip device. The device consists of two layers of linear electrodes on the top and bottom of a microfluidic channel. Each electrode layer has a 53 × 53 donut trap matrix, with traps that are linearly connected into rows along the top, and columns along the bottom of the channel. To address in this matrix a single particle in suspension, we introduce pulsed dielectrophoresis (puDEP) where the AC signal used to induce dielectrophoresis is chopped, such that only beads that are at the intersection of two perpendicular electrodes are constantly polarized. Finally, by combining puDEP and moving dielectrophoresis (mDEP), we introduce a generic application of dielectrophoresis namely moving pulsed dielectrophoresis (mpuDEP) that allows the contactless, micron accuracy, addressable displacement in a 2D array of a single bead in suspension.
Collapse
|
18
|
Suscillon C, Velev OD, Slaveykova VI. Alternating current-dielectrophoresis driven on-chip collection and chaining of green microalgae in freshwaters. BIOMICROFLUIDICS 2013; 7:24109. [PMID: 24404014 PMCID: PMC3643985 DOI: 10.1063/1.4801870] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 04/01/2013] [Indexed: 05/03/2023]
Abstract
The capability of the AC dielectrophoresis (DEP) for on-chip capture and chaining of microalgae suspended in freshwaters was evaluated. The effects of freshwater composition as well as the electric field voltage, frequency, and duration, on the dielectrophoretic response of microalga Chlamydomonas reinhardtii were characterized systematically. Highest efficiency of cell alignment in one-dimensional arrays, determined by the percentage of cells in chain and the chain length, was obtained at AC-field of 20 V mm(-1) and 1 kHz applied for 600 s. The DEP response and cell alignment of C. reinhardtii in water sampled from lake, pond, and river, as well as model media were affected by the chemical composition of the media. In the model media, the efficiency of DEP chaining was negatively correlated to the conductivity of the cell suspensions, being higher in suspensions with low conductivity. The cells suspended in freshwaters, however, showed anomalously high chaining at long exposure times. High concentrations of nitrate and dissolved organic matter decrease cell chaining efficiency, while phosphate and citrate concentrations increase it and favor formation of longer chains. Importantly, the application of AC-field had no effect on algal autofluorescence, cell membrane damage, or oxidative stress damages in C. reinhardtii.
Collapse
Affiliation(s)
- Coralie Suscillon
- Aquatic Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10, route de Suisse, CH-1290 Versoix, Switzerland
| | - Orlin D Velev
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695-7905, USA
| | - Vera I Slaveykova
- Aquatic Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10, route de Suisse, CH-1290 Versoix, Switzerland
| |
Collapse
|
19
|
Terpitz U, Sukhorukov VL, Zimmermann D. Prototype for automatable, dielectrophoretically-accessed intracellular membrane-potential measurements by metal electrodes. Assay Drug Dev Technol 2012; 11:9-16. [PMID: 22994967 DOI: 10.1089/adt.2012.455] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Functional access to membrane proteins, for example, ion channels, of individual cells is an important prerequisite in drug discovery studies. The highly sophisticated patch-clamp method is widely used for electrogenic membrane proteins, but is demanding for the operator, and its automation remains challenging. The dielectrophoretically-accessed, intracellular membrane-potential measurement (DAIMM) method is a new technique showing high potential for automation of electrophysiological data recording in the whole-cell configuration. A cell suspension is brought between a mm-scaled planar electrode and a μm-scaled tip electrode, placed opposite to each other. Due to the asymmetric electrode configuration, the application of alternating electric fields (1-5 MHz) provokes a dielectrophoretic force acting on the target cell. As a consequence, the cell is accelerated and pierced by the tip electrode, hence functioning as the internal (working) electrode. We used the light-gated cation channel Channelrhodopsin-2 as a reporter protein expressed in HEK293 cells to characterize the DAIMM method in comparison with the patch-clamp technique.
Collapse
Affiliation(s)
- Ulrich Terpitz
- Department of Biophysical Chemistry, Max Planck Institute of Biophysics, Frankfurt am Main, Germany.
| | | | | |
Collapse
|
20
|
Martinez-Duarte R. Microfabrication technologies in dielectrophoresis applications--a review. Electrophoresis 2012; 33:3110-32. [PMID: 22941778 DOI: 10.1002/elps.201200242] [Citation(s) in RCA: 111] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Revised: 06/10/2012] [Accepted: 06/11/2012] [Indexed: 11/12/2022]
Abstract
DEP is an established technique for particle manipulation. Although first demonstrated in the 1950s, it was not until the development of miniaturization techniques in the 1990s that DEP became a popular research field. The 1990s saw an explosion of DEP publications using microfabricated metal electrode arrays to sort a wide variety of cells. The concurrent development of microfluidics enabled devices for flow management and better understanding of the interaction between hydrodynamic and electrokinetic forces. Starting in the 2000s, alternative techniques have arisen to overcome common problems in metal-electrode DEP, such as electrode fouling, and to increase the throughput of the system. Insulator-based DEP and light-induced DEP are the most significant examples. Most recently, new 3D techniques such as carbon-electrode DEP, contactless DEP, and the use of doped PDMS have further simplified the fabrication process. The constant desire of the community to develop practical solutions has led to devices which are more user friendly, less expensive, and are capable of higher throughput. The state-of-the-art of fabricating DEP devices is critically reviewed in this work. The focus is on how different fabrication techniques can boost the development of practical DEP devices to be used in different settings such as clinical cell sorting and infection diagnosis, industrial food safety, and enrichment of particle populations for drug development.
Collapse
|