1
|
Kevat A, Steinkey R, Suresh S, Ruehland WR, Chawla J, Terrill PI, Collaro A, Iyer K. Evaluation of automated pediatric sleep stage classification using U-Sleep: a convolutional neural network. J Clin Sleep Med 2025; 21:277-285. [PMID: 39324691 PMCID: PMC11789265 DOI: 10.5664/jcsm.11362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2024] [Revised: 09/16/2024] [Accepted: 09/17/2024] [Indexed: 09/27/2024]
Abstract
STUDY OBJECTIVES U-Sleep is a publicly available automated sleep stager, but has not been independently validated using pediatric data. We aimed to (1) test the hypothesis that U-Sleep performance is equivalent to trained humans, using a concordance dataset of 50 pediatric polysomnogram excerpts scored by multiple trained scorers, and (2) identify clinical and demographic characteristics that impact U-Sleep accuracy, using a clinical dataset of 3,114 polysomnograms from a tertiary center. METHODS Agreement between U-Sleep and "gold" 30-second epoch sleep staging was determined across both datasets. Utilizing the concordance dataset, the hypothesis of equivalence between human scorers and U-Sleep was tested using a Wilcoxon 2 1-sided test. Multivariable regression and generalized additive modeling were used on the clinical dataset to estimate the effects of age, comorbidities, and polysomnographic findings on U-Sleep performance. RESULTS The median (interquartile range) Cohen's kappa agreement of U-Sleep and individual trained humans relative to "gold" scoring for 5-stage sleep staging in the concordance dataset were similar, kappa = 0.79 (0.19) vs 0.78 (0.13), respectively, and satisfied statistical equivalence (2 1-sided test P < .01). Median (interquartile range) kappa agreement between U-Sleep 2.0 and clinical sleep-staging was kappa = 0.69 (0.22). Modeling indicated lower performance for children < 2 years, those with medical comorbidities possibly altering sleep electroencephalography (kappa reduction = 0.07-0.15) and those with decreased sleep efficiency or sleep-disordered breathing (kappa reduction = 0.1). CONCLUSIONS While U-Sleep algorithms showed statistically equivalent performance to trained scorers, accuracy was lower in children < 2 years and those with sleep-disordered breathing or comorbidities affecting electroencephalography. U-Sleep is suitable for pediatric clinical utilization provided automated staging is followed by expert clinician review. CITATION Kevat A, Steinkey R, Suresh S, et al. Evaluation of automated pediatric sleep stage classification using U-Sleep: a convolutional neural network. J Clin Sleep Med. 2025;21(2):277-285.
Collapse
Affiliation(s)
- Ajay Kevat
- Department of Respiratory and Sleep Medicine, Queensland Children's Hospital, Brisbane, Queensland, Australia
- The University of Queensland, Brisbane, Queensland, Australia
| | - Rylan Steinkey
- The University of Queensland, Brisbane, Queensland, Australia
| | - Sadasivam Suresh
- Department of Respiratory and Sleep Medicine, Queensland Children's Hospital, Brisbane, Queensland, Australia
- The University of Queensland, Brisbane, Queensland, Australia
| | - Warren R Ruehland
- Department of Respiratory and Sleep Medicine, Austin Health, Melbourne, Victoria, Australia
- Institute for Sleep and Breathing, Melbourne, Victoria, Australia
| | - Jasneek Chawla
- Department of Respiratory and Sleep Medicine, Queensland Children's Hospital, Brisbane, Queensland, Australia
- The University of Queensland, Brisbane, Queensland, Australia
| | | | - Andrew Collaro
- Department of Respiratory and Sleep Medicine, Queensland Children's Hospital, Brisbane, Queensland, Australia
- The University of Queensland, Brisbane, Queensland, Australia
| | - Kartik Iyer
- The University of Queensland, Brisbane, Queensland, Australia
- Queensland Institute of Medical Research Berghofer Medical Research Institute, Brisbane, Queensland, Australia
| |
Collapse
|
2
|
Cheng H, Yang Y, Shi J, Li Z, Feng Y, Wang X. Comparison of automated deep neural network against manual sleep stage scoring in clinical data. Comput Biol Med 2024; 179:108855. [PMID: 39029432 DOI: 10.1016/j.compbiomed.2024.108855] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 07/04/2024] [Accepted: 07/05/2024] [Indexed: 07/21/2024]
Abstract
OBJECTIVE To compare the accuracy and generalizability of an automated deep neural network and the Philip Sleepware G3™ Somnolyzer system (Somnolyzer) for sleep stage scoring using American Academy of Sleep Medicine (AASM) guidelines. METHODS Sleep recordings from 104 participants were analyzed by a convolutional neural network (CNN), the Somnolyzer and skillful technicians. Evaluation metrics were derived for different combinations of sleep stages. A further comparison between the Somnolyzer and the CNN model using a single-channel signal as input was also performed. Sleep recordings from 263 participants with a lower prevalence of OSA served as a cross-validation dataset to validate the generalizability of the CNN model. RESULTS The overall agreement between automated and manual scoring for sleep staging in 104 participants outperformed that of the Somnolyzer according to various metrics (accuracy: 81.81 % vs. 77.07 %; F1: 76.36 % vs. 73.80 %; Cohen's kappa: 0.7403 vs. 0.6848). The results showed that the left electrooculography (EOG) single-channel model had minor advantages over the Somnolyzer. In terms of consistency with manual sleep staging, the CNN model demonstrated superior performance in identifying more pronounced sleep transitions, particularly in the N2 stage and sleep latency metrics. Conversely, the Somnolyzer showed enhanced proficiency in the analysis of REM stages, notably in measuring REM latency. The accuracy in the cross-validation set of 263 participants was also above 80 %. CONCLUSIONS The CNN-based automated deep neural network outperformed the Somnolyzer and is sufficiently accurate for sleep study analyses using the AASM classification criteria.
Collapse
Affiliation(s)
- Hanrong Cheng
- Department of Sleep Medicine, Institute of Respiratory Diseases, Shenzhen People's Hospital, The Second Clinical Medical College of Jinan University, The First Affiliated Hospital of Southern University of Science and Technology, Shenzhen, 518020, China.
| | - Yifei Yang
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Jingshu Shi
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Zhangbo Li
- Shenzhen Gianta Information Technology Co., LTD, Shenzhen, 518048, China
| | - Yang Feng
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China
| | - Xingjun Wang
- Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, 518055, China.
| |
Collapse
|
3
|
van Twist E, Hiemstra FW, Cramer AB, Verbruggen SC, Tax DM, Joosten K, Louter M, Straver DC, de Hoog M, Kuiper JW, de Jonge RC. An electroencephalography-based sleep index and supervised machine learning as a suitable tool for automated sleep classification in children. J Clin Sleep Med 2024; 20:389-397. [PMID: 37869968 PMCID: PMC11019221 DOI: 10.5664/jcsm.10880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 10/18/2023] [Accepted: 10/18/2023] [Indexed: 10/24/2023]
Abstract
STUDY OBJECTIVES Although sleep is frequently disrupted in the pediatric intensive care unit, it is currently not possible to perform real-time sleep monitoring at the bedside. In this study, spectral band powers of electroencephalography data are used to derive a simple index for sleep classification. METHODS Retrospective study at Erasmus MC Sophia Children's Hospital, using hospital-based polysomnography recordings obtained in non-critically ill children between 2017 and 2021. Six age categories were defined: 6-12 months, 1-3 years, 3-5 years, 5-9 years, 9-13 years, and 13-18 years. Candidate index measures were derived by calculating spectral band powers in different frequent frequency bands of smoothed electroencephalography. With the best performing index, sleep classification models were developed for two, three, and four states via decision tree and five-fold nested cross-validation. Model performance was assessed across age categories and electroencephalography channels. RESULTS In total 90 patients with polysomnography were included, with a mean (standard deviation) recording length of 10.3 (1.1) hours. The best performance was obtained with the gamma to delta spectral power ratio of the F4-A1 and F3-A1 channels with smoothing. Balanced accuracy was 0.88, 0.74, and 0.57 for two-, three-, and four-state classification. Across age categories, balanced accuracy ranged between 0.83 and 0.92 and 0.72 and 0.77 for two- and three-state classification, respectively. CONCLUSIONS We propose an interpretable and generalizable sleep index derived from single-channel electroencephalography for automated sleep monitoring at the bedside in non-critically ill children ages 6 months to 18 years, with good performance for two- and three-state classification. CITATION van Twist E, Hiemstra FW, Cramer ABG, et al. An electroencephalography-based sleep index and supervised machine learning as a suitable tool for automated sleep classification in children. J Clin Sleep Med. 2024;20(3):389-397.
Collapse
Affiliation(s)
- Eris van Twist
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - Floor W. Hiemstra
- Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands
- Laboratory for Neurophysiology, Department of Cellular and Chemical Biology, Leiden University Medical Center, Leiden, The Netherlands
| | - Arnout B.G. Cramer
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - Sascha C.A.T. Verbruggen
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - David M.J. Tax
- Pattern Recognition Laboratory, Delft University of Technology, Delft, The Netherlands
| | - Koen Joosten
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - Maartje Louter
- Division of Clinical Neurophysiology, Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
| | - Dirk C.G. Straver
- Division of Clinical Neurophysiology, Department of Neurology, Erasmus MC, Rotterdam, The Netherlands
| | - Matthijs de Hoog
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - Jan Willem Kuiper
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| | - Rogier C.J. de Jonge
- Department of Neonatal and Pediatric Intensive Care, Division of Pediatric Intensive Care, Erasmus MC Sophia Children’s Hospital, Rotterdam, The Netherlands
| |
Collapse
|
4
|
Vaquerizo-Villar F, Gutiérrez-Tobal GC, Calvo E, Álvarez D, Kheirandish-Gozal L, Del Campo F, Gozal D, Hornero R. An explainable deep-learning model to stage sleep states in children and propose novel EEG-related patterns in sleep apnea. Comput Biol Med 2023; 165:107419. [PMID: 37703716 DOI: 10.1016/j.compbiomed.2023.107419] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/26/2023] [Accepted: 08/28/2023] [Indexed: 09/15/2023]
Abstract
Automatic deep-learning models used for sleep scoring in children with obstructive sleep apnea (OSA) are perceived as black boxes, limiting their implementation in clinical settings. Accordingly, we aimed to develop an accurate and interpretable deep-learning model for sleep staging in children using single-channel electroencephalogram (EEG) recordings. We used EEG signals from the Childhood Adenotonsillectomy Trial (CHAT) dataset (n = 1637) and a clinical sleep database (n = 980). Three distinct deep-learning architectures were explored to automatically classify sleep stages from a single-channel EEG data. Gradient-weighted Class Activation Mapping (Grad-CAM), an explainable artificial intelligence (XAI) algorithm, was then applied to provide an interpretation of the singular EEG patterns contributing to each predicted sleep stage. Among the tested architectures, a standard convolutional neural network (CNN) demonstrated the highest performance for automated sleep stage detection in the CHAT test set (accuracy = 86.9% and five-class kappa = 0.827). Furthermore, the CNN-based estimation of total sleep time exhibited strong agreement in the clinical dataset (intra-class correlation coefficient = 0.772). Our XAI approach using Grad-CAM effectively highlighted the EEG features associated with each sleep stage, emphasizing their influence on the CNN's decision-making process in both datasets. Grad-CAM heatmaps also allowed to identify and analyze epochs within a recording with a highly likelihood to be misclassified, revealing mixed features from different sleep stages within these epochs. Finally, Grad-CAM heatmaps unveiled novel features contributing to sleep scoring using a single EEG channel. Consequently, integrating an explainable CNN-based deep-learning model in the clinical environment could enable automatic sleep staging in pediatric sleep apnea tests.
Collapse
Affiliation(s)
- Fernando Vaquerizo-Villar
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain.
| | - Gonzalo C Gutiérrez-Tobal
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| | - Eva Calvo
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain
| | - Daniel Álvarez
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - Leila Kheirandish-Gozal
- Departments of Neurology and Child Health and Child Health Research Institute, The University of Missouri School of Medicine, Columbia, MO, USA
| | - Félix Del Campo
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain; Sleep-Ventilation Unit, Pneumology Department, Río Hortega University Hospital, Valladolid, Spain
| | - David Gozal
- Office of The Dean, Joan C. Edwards School of Medicine, Marshall University, 1600 Medical Center Dr, Huntington, WV, 25701, USA
| | - Roberto Hornero
- Biomedical Engineering Group, University of Valladolid, Valladolid, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina, Instituto de Salud Carlos III, Valladolid, Spain
| |
Collapse
|
5
|
Liu Z, Alavi A, Li M, Zhang X. Self-Supervised Contrastive Learning for Medical Time Series: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:4221. [PMID: 37177423 PMCID: PMC10181273 DOI: 10.3390/s23094221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023]
Abstract
Medical time series are sequential data collected over time that measures health-related signals, such as electroencephalography (EEG), electrocardiography (ECG), and intensive care unit (ICU) readings. Analyzing medical time series and identifying the latent patterns and trends that lead to uncovering highly valuable insights for enhancing diagnosis, treatment, risk assessment, and disease progression. However, data mining in medical time series is heavily limited by the sample annotation which is time-consuming and labor-intensive, and expert-depending. To mitigate this challenge, the emerging self-supervised contrastive learning, which has shown great success since 2020, is a promising solution. Contrastive learning aims to learn representative embeddings by contrasting positive and negative samples without the requirement for explicit labels. Here, we conducted a systematic review of how contrastive learning alleviates the label scarcity in medical time series based on PRISMA standards. We searched the studies in five scientific databases (IEEE, ACM, Scopus, Google Scholar, and PubMed) and retrieved 1908 papers based on the inclusion criteria. After applying excluding criteria, and screening at title, abstract, and full text levels, we carefully reviewed 43 papers in this area. Specifically, this paper outlines the pipeline of contrastive learning, including pre-training, fine-tuning, and testing. We provide a comprehensive summary of the various augmentations applied to medical time series data, the architectures of pre-training encoders, the types of fine-tuning classifiers and clusters, and the popular contrastive loss functions. Moreover, we present an overview of the different data types used in medical time series, highlight the medical applications of interest, and provide a comprehensive table of 51 public datasets that have been utilized in this field. In addition, this paper will provide a discussion on the promising future scopes such as providing guidance for effective augmentation design, developing a unified framework for analyzing hierarchical time series, and investigating methods for processing multimodal data. Despite being in its early stages, self-supervised contrastive learning has shown great potential in overcoming the need for expert-created annotations in the research of medical time series.
Collapse
Affiliation(s)
- Ziyu Liu
- School of Computing Technologies, RMIT, Melbourne, VIC 3000, Australia;
| | - Azadeh Alavi
- School of Computing Technologies, RMIT, Melbourne, VIC 3000, Australia;
| | - Minyi Li
- Coles, Melbourne, VIC 3123, Australia;
| | - Xiang Zhang
- Department of Computer Science, University of North Carolina, Charlotte, NC 28223, USA
| |
Collapse
|
6
|
Nazih W, Shahin M, Eldesouki MI, Ahmed B. Influence of Channel Selection and Subject's Age on the Performance of the Single Channel EEG-Based Automatic Sleep Staging Algorithms. SENSORS (BASEL, SWITZERLAND) 2023; 23:899. [PMID: 36679711 PMCID: PMC9866121 DOI: 10.3390/s23020899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/08/2023] [Accepted: 01/10/2023] [Indexed: 06/17/2023]
Abstract
The electroencephalogram (EEG) signal is a key parameter used to identify the different sleep stages present in an overnight sleep recording. Sleep staging is crucial in the diagnosis of several sleep disorders; however, the manual annotation of the EEG signal is a costly and time-consuming process. Automatic sleep staging algorithms offer a practical and cost-effective alternative to manual sleep staging. However, due to the limited availability of EEG sleep datasets, the reliability of existing sleep staging algorithms is questionable. Furthermore, most reported experimental results have been obtained using adult EEG signals; the effectiveness of these algorithms using pediatric EEGs is unknown. In this paper, we conduct an intensive study of two state-of-the-art single-channel EEG-based sleep staging algorithms, namely DeepSleepNet and AttnSleep, using a recently released large-scale sleep dataset collected from 3984 patients, most of whom are children. The paper studies how the performance of these sleep staging algorithms varies when applied on different EEG channels and across different age groups. Furthermore, all results were analyzed within individual sleep stages to understand how each stage is affected by the choice of EEG channel and the participants' age. The study concluded that the selection of the channel is crucial for the accuracy of the single-channel EEG-based automatic sleep staging methods. For instance, channels O1-M2 and O2-M1 performed consistently worse than other channels for both algorithms and through all age groups. The study also revealed the challenges in the automatic sleep staging of newborns and infants (1-52 weeks).
Collapse
Affiliation(s)
- Waleed Nazih
- College of Computer Engineering and Sciences, Prince Sattam bin Abdulaziz University, Al Kharj 11942, Saudi Arabia
| | - Mostafa Shahin
- School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW 2052, Australia
| | - Mohamed I. Eldesouki
- College of Computer Engineering and Sciences, Prince Sattam bin Abdulaziz University, Al Kharj 11942, Saudi Arabia
| | - Beena Ahmed
- School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW 2052, Australia
| |
Collapse
|
7
|
Somaskandhan P, Leppänen T, Terrill PI, Sigurdardottir S, Arnardottir ES, Ólafsdóttir KA, Serwatko M, Sigurðardóttir SÞ, Clausen M, Töyräs J, Korkalainen H. Deep learning-based algorithm accurately classifies sleep stages in preadolescent children with sleep-disordered breathing symptoms and age-matched controls. Front Neurol 2023; 14:1162998. [PMID: 37122306 PMCID: PMC10140398 DOI: 10.3389/fneur.2023.1162998] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 03/23/2023] [Indexed: 05/02/2023] Open
Abstract
Introduction Visual sleep scoring has several shortcomings, including inter-scorer inconsistency, which may adversely affect diagnostic decision-making. Although automatic sleep staging in adults has been extensively studied, it is uncertain whether such sophisticated algorithms generalize well to different pediatric age groups due to distinctive EEG characteristics. The preadolescent age group (10-13-year-olds) is relatively understudied, and thus, we aimed to develop an automatic deep learning-based sleep stage classifier specifically targeting this cohort. Methods A dataset (n = 115) containing polysomnographic recordings of Icelandic preadolescent children with sleep-disordered breathing (SDB) symptoms, and age and sex-matched controls was utilized. We developed a combined convolutional and long short-term memory neural network architecture relying on electroencephalography (F4-M1), electrooculography (E1-M2), and chin electromyography signals. Performance relative to human scoring was further evaluated by analyzing intra- and inter-rater agreements in a subset (n = 10) of data with repeat scoring from two manual scorers. Results The deep learning-based model achieved an overall cross-validated accuracy of 84.1% (Cohen's kappa κ = 0.78). There was no meaningful performance difference between SDB-symptomatic (n = 53) and control subgroups (n = 52) [83.9% (κ = 0.78) vs. 84.2% (κ = 0.78)]. The inter-rater reliability between manual scorers was 84.6% (κ = 0.78), and the automatic method reached similar agreements with scorers, 83.4% (κ = 0.76) and 82.7% (κ = 0.75). Conclusion The developed algorithm achieved high classification accuracy and substantial agreements with two manual scorers; the performance metrics compared favorably with typical inter-rater reliability between manual scorers and performance reported in previous studies. These suggest that our algorithm may facilitate less labor-intensive and reliable automatic sleep scoring in preadolescent children.
Collapse
Affiliation(s)
- Pranavan Somaskandhan
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia
- *Correspondence: Pranavan Somaskandhan,
| | - Timo Leppänen
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| | - Philip I. Terrill
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia
| | - Sigridur Sigurdardottir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
| | - Erna Sif Arnardottir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
- Internal Medicine Services, Landspitali–The National University Hospital of Iceland, Reykjavik, Iceland
| | - Kristín A. Ólafsdóttir
- Reykjavik University Sleep Institute, School of Technology, Reykjavik University, Reykjavik, Iceland
| | - Marta Serwatko
- Department of Clinical Engineering, Landspitali University Hospital, Reykjavik, Iceland
| | - Sigurveig Þ. Sigurðardóttir
- Department of Immunology, Landspitali University Hospital, Reykjavik, Iceland
- Faculty of Medicine, University of Iceland, Reykjavik, Iceland
| | - Michael Clausen
- Department of Allergy, Landspitali University Hospital, Reykjavik, Iceland
- Children's Hospital Reykjavik, Reykjavik, Iceland
| | - Juha Töyräs
- School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD, Australia
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Science Service Center, Kuopio University Hospital, Kuopio, Finland
| | - Henri Korkalainen
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
- Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland
| |
Collapse
|