Hiraiwa T, Tsujimoto N, Tanimoto K, Terasaki J, Amino N, Hanafusa T. Use of color Doppler ultrasonography to measure thyroid blood flow and differentiate graves' disease from painless thyroiditis.
Eur Thyroid J 2013;
2:120-6. [PMID:
24783050 PMCID:
PMC3821509 DOI:
10.1159/000350560]
[Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2012] [Revised: 03/03/2013] [Indexed: 11/19/2022] Open
Abstract
BACKGROUNDS
Color Doppler ultrasonography (CDU) has not yet been established as a method to investigate the pathogenesis of thyrotoxicosis.
OBJECTIVES
Our first objective was to determine whether the measurement of peak systolic blood-flow velocity in the superior thyroid artery (STV) and thyroid tissue blood flow (TBF) using CDU could differentiate Graves' disease (GD) from painless thyroiditis (PT). The second objective was to examine the factors mediating increased blood flow to the thyroid gland in GD.
METHODS
Recruited patients had untreated GD or PT and visited the Department of Internal Medicine (I), Osaka Medical College, between April 1, 2006 and May 31, 2010. Age, gender, blood pressure, pulse rate, thyroid-stimulating hormone, free thyroxine, tri-iodothyronine, TSH receptor antibody and thyroid volume were evaluated in patients. In addition, bilateral measurements of STV, TBF and peak systolic velocity in the common carotid artery (CCV) were also performed. TBF was quantified by calculating the ratio of blood-flow pixels to total pixels in the region of interest using sagittal section images of the thyroid gland. Receiver-operating characteristic curve analysis was performed to determine the ability of STV and TBF measurements to differentiate GD from PT.
RESULTS
For the average of STV measured on both sides, the area under the receiver-operating characteristic curve (AUC) was 0.956. For the average of TBF measured on both sides, the AUC was 0.920. At an average STV cut-off value of 43 cm/s, the sensitivity to discriminate GD from PT was 0.87 and the specificity was 1.00. At an average TBF cut-off value of 3.8%, the sensitivity was 0.71 and the specificity was 1.00. In the GD group, neither blood pressure nor pulse rate correlated with the average STV or TBF. Moreover, there was no correlation between STV and CCV or between TBF and CCV on either side. However, STV was correlated with TBF (right side: R = 0.47; left side: R = 0.52).
CONCLUSIONS
The results demonstrate that STV and TBF are useful for differentiating GD from PT. Furthermore, the increased STV and TBF found in GD are not related to hyperthyroidism-induced increases in systolic blood pressure, pulse rate or CCV.
Collapse