1
|
Kutzler M, Patterson JT, Anz H, Siahaan J, Warner SJ, Gary JL. Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:2147-2153. [PMID: 38564013 DOI: 10.1007/s00590-024-03919-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Accepted: 03/14/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Distal femur fractures account for 3-6% of all femur fractures. Internal fixation of most distal femur fractures with an anatomic lateral locking plate should permit some motion at the metaphyseal portion of the fracture when secondary bone healing is planned by the operating surgeon. While several studies have been performed evaluating union rates for distal femur fractures with stainless steel and titanium plates, the timing of callus formation between stainless steel and titanium implants used as bridge plates for distal femur fractures (AO/OTA 33-A and -C) has been investigated to a lesser extent. We hypothesize that callus will be visualized earlier with post-operative radiographs with titanium versus stainless steel bridge plates. METHODS We retrospectively reviewed a consecutive cohort of patients over 18 years of age with acute AO/OTA 33-A and 33-C fracture patterns treated with an isolated stainless steel or titanium lateral bridge plate within 4 weeks of injury by a single fellowship-trained orthopedic trauma surgeon from 2011 to 2020 at one academic Level 1 trauma center. An independent, fellowship-trained orthopedic trauma attending surgeon reviewed anterior-posterior (AP) and lateral radiographs from every available post-operative clinic visit and graded them using the Modified Radiographic Score for Tibia (mRUST). RESULTS Twenty-five subjects were included in the study with 10 with stainless steel and 15 with titanium plates. There were no significant differences in demographics between both groups, including age, sex, BMI, injury classification, open versus closed, mechanism, and laterality. Statistically significant increased mRUST scores, indicating increased callus formation, were seen on 12-week radiographs (8.4 vs. 11.9, p = 0.02) when titanium bridge plates were used. There were no statistically significant differences in mRUST scores at 6 or 24-weeks, but scores in the titanium group were higher in at every timepoint. DISCUSSION In conclusion, we observed greater callus formation at 12 weeks after internal fixation of 33-A and 33-C distal femur fractures treated with titanium locked lateral distal femoral bridge plates compared to stainless steel plates. Our data suggest that titanium metallurgy may have quicker callus formation compared to stainless steel if an isolated, lateral locked bridge plate is chosen for distal femur fracture fixation.
Collapse
Affiliation(s)
- Michael Kutzler
- Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA
| | - Joseph T Patterson
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo St. Suite 2000, Los Angeles, CA, 90033, USA
| | - Hayden Anz
- Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA
| | - Jacob Siahaan
- Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA
| | - Stephen J Warner
- Department of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA
| | - Joshua L Gary
- Department of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo St. Suite 2000, Los Angeles, CA, 90033, USA.
| |
Collapse
|
2
|
Singh R, Ambade R, Landge S, Goyal S, Goel S. Comprehensive Review on Distal Femur Fractures: From Epidemiology to Treatment Strategies. Cureus 2024; 16:e57937. [PMID: 38738010 PMCID: PMC11084923 DOI: 10.7759/cureus.57937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 04/09/2024] [Indexed: 05/14/2024] Open
Abstract
Distal femur fractures present a substantial orthopedic challenge, necessitating a comprehensive exploration spanning epidemiology, anatomy, classification, diagnosis, and treatment strategies. This review thoroughly analyzes the multifaceted aspects surrounding distal femur fractures. It delves into the definition and epidemiology, shedding light on the incidence, age distribution, and associated risk factors. An exhaustive examination of the distal femur's anatomy, encompassing ligaments and tendons, establishes the groundwork for understanding fracture patterns and subsequent classification according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA) system. Diagnostic considerations encompass physical examination and various imaging modalities, emphasizing the critical importance of prompt and accurate assessment. The extensive discussion on treatment options ranges from non-surgical management, including casting and traction, to surgical interventions, such as open reduction and internal fixation, intramedullary nailing, and external fixation. The implications for clinical practice underscore the necessity for tailored approaches based on fracture characteristics to optimize patient outcomes. However, this review also emphasizes areas necessitating further investigation, including exploring predictive biomarkers, advanced surgical techniques, and innovative rehabilitation protocols. Insights from long-term outcomes and quality-of-life assessments in diverse populations offer promising avenues for enhancing the comprehensive management of distal femur fractures. Continuous research in these areas can refine treatment strategies and elevate the standard of care for individuals grappling with this intricate orthopedic condition.
Collapse
Affiliation(s)
- Rahul Singh
- Department of Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Ratnakar Ambade
- Department of Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Suhas Landge
- Department of Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Saksham Goyal
- Department of Orthopaedic Surgery, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Sachin Goel
- Department of Orthopaedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
3
|
Tayyebi H, Noorigaravand S, Baheaddini MR, Mohammadyahya E, Parvandi A, Shirvani S, Yeganeh A. The Impact of Delayed Osteosynthesis of Bone Healing in Patients with Extra-articular Distal Femoral Fracture. Med J Islam Repub Iran 2024; 38:25. [PMID: 38783980 PMCID: PMC11114186 DOI: 10.47176/mjiri.38.25] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Indexed: 05/25/2024] Open
Abstract
Background In extra-articular distal femoral fractures (EDFFs), nonunion is a serious complication that occurs rarely. In this study, we examined how longer preservation of initial fracture hematoma by delaying the osteosynthesis (OS) affects the fracture union. Methods In a retrospective cohort study, 98 EDFF patients were included. The OS was done within 2 days of injury in 50 patients (early OS group) and after 2 days of injury in 48 patients (late OS group). Time to callus formation and fracture union, bleeding amount, surgical duration, pain, knee range of motion, knee function, and postoperative complications, including the nonunion, knee deformity, infection, and revision, were compared between the 2 groups. Statistical analyses were done with SPSS. A comparison of the mean between the 2 groups was made with an independent t test or its nonparametric counterpart. A comparison of categorical variables between the 2 groups was made using a chi-square or the Fisher's exact test. P ˂ 0.05 was considered statistically significant. Results The mean time to callus formation was 47.1 ± 17.3 days in the early OS group and 46.9 ± 19.7 in the late OS group (P = 0.950). The mean time to fracture union was 114.9 ± 21 in the early OS group and 117.4 ± 28.8 days in the late OS group (P = 0.630). The mean operation time and bleeding amount between the 2 groups did not differ significantly (P = 0.230 and P = 0.340, respectively). The knee range of motion, pain, and function were not notably different (P = 0.620, P = 0.790, and P = 0.770, respectively). Nonunion occurred in 3 patients of early OS and 2 patients of the late OS group. Other complications were also comparable in the 2 study groups. Conclusion Delayed OA in EDFF patients has no significant effect on bone healing and fracture union. Future standard studies are required to confirm these results.
Collapse
Affiliation(s)
- Hamed Tayyebi
- Shohadaye Haftom-e-Tir Hospital, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Sajad Noorigaravand
- Shohadaye Haftom-e-Tir Hospital, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Mohammad Reza Baheaddini
- Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Elham Mohammadyahya
- Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Ava Parvandi
- Joint and Related Tissue Research Center, Akhtar Orthopedic Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Saeid Shirvani
- Shohadaye Haftom-e-Tir Hospital, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Yeganeh
- Bone and Joint Reconstruction Research Center, Department of Orthopedics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Huppke CM, Fahlbusch H, Frosch KH, Krause M, von Rehlingen-Prinz F. Cortical bone thickness on preoperative CT scans as predictor of bone quality in distal femur fractures: a retrospective study in Caucasians. Arch Orthop Trauma Surg 2024; 144:731-740. [PMID: 38049535 PMCID: PMC10822795 DOI: 10.1007/s00402-023-05131-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Accepted: 11/07/2023] [Indexed: 12/06/2023]
Abstract
AIM Distal femur fractures (DFF) are rare, but associated with high complication rates and mortality, particularly in patients with osteoporosis. To improve preoperative assessment, we analyzed if cortical bone thickness on CT and AP radiographs is associated with clinical parameters of bone quality. METHODS Retrospective single-center study of adult patients presenting at a level-one trauma center, with a DFF between 2011 and 2020. Clinical parameters for bone quality, such as age, sex, body mass index (BMI), energy impact level of trauma, and known history of osteoporosis, were assessed. Mean cortical bone thickness (CBTavg) on AP radiograph was determined using a previously published method. Cortical thickness on CT scan was measured at 8 and 14 cm proximal to the articular surface of the lateral condyle. RESULTS 71 patients (46 females) between 20 and 100 years were included in the study. Cortical thickness determined by CT correlated significantly with CBTavg measurements on AP radiograph (Spearman r = 0.62 to 0.80; p < 0.001). Cortical thickness was inversely correlated with age (Spearman r = - 0.341 to - 0.466; p < 0.001) and significantly associated with trauma impact level and history of osteoporosis (p = < 0.001). The CT-based values showed a stronger correlation with the clinical parameters than those determined by AP X-ray. CONCLUSION Our results showed that cortical thickness of the distal femur correlates with clinical parameters of bone quality and is therefore an excellent tool for assessing what surgical care should be provided. Interestingly, our findings indicate that cortical thickness on CT is more strongly correlated with clinical data than AP radiograph measurements.
Collapse
Affiliation(s)
- Calvin M Huppke
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Hendrik Fahlbusch
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| | - Karl-Heinz Frosch
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Hospital Hamburg, Bergedorfer Str. 10, 21033, Hamburg, Germany
| | - Matthias Krause
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany.
- Klinik und Poliklinik für Unfallchirurgie und Orthopädie, Universitätsklinikum Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Deutschland.
| | - Fidelius von Rehlingen-Prinz
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20251, Hamburg, Germany
| |
Collapse
|
5
|
Roytman GR, Jabbouri SS, O'Marr J, Raghuram A, Beitler B, Irshad S, Fram BR, Yoo BJ, Leslie MP, Riedel MD, Tommasini SM, Wiznia DH. Outcomes of Distal Third Femur Fractures in Patients 18 Years and Older: A Pilot Study. Cureus 2024; 16:e55136. [PMID: 38558586 PMCID: PMC10979706 DOI: 10.7759/cureus.55136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/27/2024] [Indexed: 04/04/2024] Open
Abstract
INTRODUCTION The selection of the most optimal fixation method for fractures of the distal femur, whether intramedullary nail (NL), lateral locking plate (PL), or nail/plate (NP) is not always clear. This study retrospectively evaluates surgical patients with distal femur fractures and introduces a pilot study using cluster analysis to identify the most optimal fracture fixation method for a given fracture type. METHODS This is a retrospective cohort study of patients 18 years and older with an isolated distal femur fracture who presented to our Level-1 trauma center between January 1, 2012, and December 31, 2022, and obtained NL, PL, or NP implants. Patients with polytrauma and those without at least six months of follow-up were excluded. A chart review was used to obtain demographics, fracture classification, fixation method, and postoperative complications. A cluster analysis was performed. The following factors were used to determine a successful outcome: ambulatory status pre-injury and 6-12 months postoperatively, infection, non-union, mortality, and implant failure. RESULTS A total of 169 patients met inclusion criteria. No statistically significant association between the fracture classification and fixation type with overall outcome was found. However, patients treated with an NP (n = 14) had a success rate of 92.9% vs only a 68.1% success rate in those treated with a PL (n = 116) (p = 0.106). The most notable findings in the cluster analysis (15 total clusters) included transverse extraarticular fractures demonstrating 100% success if treated with NP (n = 6), 50% success with NL (n=2), and 78.57% success with PL fixation (n=14). NP constructs in complete articular fractures demonstrated success in 100% of patients (n = 5), whereas 77.78% of patients treated with NL (n = 9) and 61.36% of those treated with PL (n = 44). CONCLUSIONS Plate fixation was the predominant fixation method used for distal third femur fractures regardless of fracture classification. However, NP constructs trended towards improved success rates, especially in complete intraarticular and transverse extraarticular fractures, suggesting the potential benefit of additional fixation with these fractures. Cluster analysis provided a heuristic way of creating patient profiles in patients with distal third femur fractures. However, a larger cohort study is needed to corroborate these findings to ultimately develop a clinical decision-making tool that also accounts for patient specific characteristics.
Collapse
Affiliation(s)
- Gregory R Roytman
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Sahir S Jabbouri
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Jamieson O'Marr
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Akshay Raghuram
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | | | - Suhail Irshad
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Brianna R Fram
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Brad J Yoo
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Michael P Leslie
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Matthew D Riedel
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Steven M Tommasini
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| | - Daniel H Wiznia
- Orthopaedics and Rehabilitation, Yale School of Medicine, New Haven, USA
| |
Collapse
|
6
|
Pfister B, Wilson A, Drobetz H. Best of Both Worlds? Fixation of Distal Femur Fractures with the Nail-Plate Construct. Orthop Surg 2023; 15:3326-3334. [PMID: 37866825 PMCID: PMC10694005 DOI: 10.1111/os.13927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/16/2023] [Accepted: 09/21/2023] [Indexed: 10/24/2023] Open
Abstract
OBJECTIVES Distal femoral fractures are a significant injury sustained by low- and high-energy trauma. Common treatment practices are lateral locking plate or intramedullary nail fixation, with disadvantages including risk of non and malunion and limited post-operative weightbearing status. Combining both techniques as a nail-plate construct (NPC) theoretically achieves enhanced fixation to allow immediate weightbearing. The aim of this study is to examine radiographic union, malunion and patient-reported outcomes in distal femur NPC fixation. METHODS Single-center retrospective study including all patients >18 years who sustained distal femur fractures treated with NPC. Primary outcomes were radiographic union, malunion and patient reported outcome measures at minimum 1-year follow-up. Secondary outcome measures included post-operative mobility, length of stay and complications. Relevant variables of normality are reported as mean with standard deviation. Subgroup analysis of patients aged <65 and ≥65 years are provided. RESULTS Sixteen patients were included in the study. Rate of radiographic union was 100%. There was no case of malunion. All patients were allowed to bear full weight immediately post-operatively. Mean length of stay was 9.50 days, with 37.5% of patients discharged directly home. The majority (85.7%) of patients returned to pre-injury mobility. Early post-operative complications occurred in three patients. Three patients returned to theater. The mean EQ-5D-5L index value was 0.713, with 71.4% describing no problems with self-care and 85.7% reporting no or slight problems with usual daily activities. CONCLUSION The NPC provided stable fixation permitting full weightbearing post-operatively with no cases of non or malunion. Return to pre-injury mobility and activity are encouraging. Based on these results we support the use of nail-plate construct fixation in the management of distal femur fractures.
Collapse
Affiliation(s)
- Benjamin Pfister
- Orthopaedic Surgery DepartmentLismore Base HospitalLismoreNSWAustralia
| | - Anthony Wilson
- Orthopaedic Surgery DepartmentLismore Base HospitalLismoreNSWAustralia
| | - Herwig Drobetz
- Orthopaedic Surgery DepartmentLismore Base HospitalLismoreNSWAustralia
| |
Collapse
|
7
|
Roytman GR, Beitler B, LaMonica J, Spero M, Toy K, Ramji AF, Yoo B, Leslie MP, Baumgaertner M, Tommasini SM, Wiznia DH. An analytical model of lateral condylar plate working length. Clin Biomech (Bristol, Avon) 2023; 110:106129. [PMID: 37871506 PMCID: PMC10848195 DOI: 10.1016/j.clinbiomech.2023.106129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 10/10/2023] [Accepted: 10/17/2023] [Indexed: 10/25/2023]
Abstract
BACKGROUND The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing. METHODS First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains. FINDINGS In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%. INTERPRETATION The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.
Collapse
Affiliation(s)
- Gregory R Roytman
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA; Biomedical Engineering, Yale University School of Engineering & Applied Science, 17 Hillhouse Avenue, New Haven, CT 06520, USA.
| | - Brian Beitler
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Julia LaMonica
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Matthew Spero
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Kendal Toy
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Alim F Ramji
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Brad Yoo
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Michael P Leslie
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Michael Baumgaertner
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA
| | - Steven M Tommasini
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA; Biomedical Engineering, Yale University School of Engineering & Applied Science, 17 Hillhouse Avenue, New Haven, CT 06520, USA
| | - Daniel H Wiznia
- Orthopaedics and Rehabilitation, Yale University School of Medicine, 47 College Place, New Haven, CT 06510, USA; Mechanical Engineering & Materials Science, Yale University School of Engineering & Applied Science, 17 Hillhouse Avenue, New Haven, CT 06520, USA
| |
Collapse
|
8
|
Yoo J, Kwak D, Kim J, Kwon S, Kwon J, Hwang J. Risk Factors of Proximal Screw Breakage of Locking Plate (ZPLP ®) after MIPO for Distal Femur Fractures -Analysis of Patients with Plate Removal after Bony Union. J Clin Med 2023; 12:6345. [PMID: 37834989 PMCID: PMC10573958 DOI: 10.3390/jcm12196345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 09/23/2023] [Accepted: 09/26/2023] [Indexed: 10/15/2023] Open
Abstract
BACKGROUND Locking a compression plate is a more favorable surgical technique than intramedullary nailing in the treatment of distal femur fractures. This study analyzed the risk factors of proximal screw breakage retrospectively, which was confirmed in the patients with plate removal after bony union. METHODS A total of 140 patients who were fixed by MIPO using ZPLP from 2009 to 2019 were identified. A total of 42 patients met the inclusion criteria and were included. The screw breakage group (12 patients) and the non-breakage group (30 patients) were compared. RESULTS Approximately 12 (28.6%) of 42 plate-removal patients showed proximal screw breakage. The breakage of proximal screws developed at the junction of the screw head and neck. The number of broken proximal screws averaged 1.4 (1~4). The breakage of the proximal screw even after the bony union is more frequent in older patients (p = 0.023), the dominant side (p = 0.025), the use of the cortical screw as the proximal uppermost screw (p = 0.039), and the higher plate-screw density (p = 0.048). CONCLUSIONS Advanced age, dominant side, use of the cortical screw as the uppermost screw, and higher plate-screw density were related to proximal screw breakage. When the plate is removed after bony union or delayed union is shown in these situations, the possibility of proximal screw breakage should be kept in mind.
Collapse
Affiliation(s)
- Jehyun Yoo
- Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Anyang-si 14068, Republic of Korea; (J.Y.); (D.K.)
| | - Daekyung Kwak
- Department of Orthopaedic Surgery, Hallym University Sacred Heart Hospital, Anyang-si 14068, Republic of Korea; (J.Y.); (D.K.)
| | - Joongil Kim
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1 Singil-ro, Yeongdeungpo-gu, Seoul 07441, Republic of Korea; (J.K.); (S.K.); (J.K.)
| | - Seungcheol Kwon
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1 Singil-ro, Yeongdeungpo-gu, Seoul 07441, Republic of Korea; (J.K.); (S.K.); (J.K.)
| | - Junhyuk Kwon
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1 Singil-ro, Yeongdeungpo-gu, Seoul 07441, Republic of Korea; (J.K.); (S.K.); (J.K.)
| | - Jihyo Hwang
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1 Singil-ro, Yeongdeungpo-gu, Seoul 07441, Republic of Korea; (J.K.); (S.K.); (J.K.)
| |
Collapse
|
9
|
Von Rehlingen-Prinz F, Eggeling L, Dehoust J, Huppke C, Strahl A, Neumann-Langen MV, Glaab R, Frosch KH, Krause M. Current standard of care for distal femur fractures in Germany and Switzerland. Injury 2023; 54:110936. [PMID: 37516571 DOI: 10.1016/j.injury.2023.110936] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 07/09/2023] [Accepted: 07/10/2023] [Indexed: 07/31/2023]
Abstract
BACKGROUND Distal femur fractures occur with an incidence of 4.5/100,000 and show a prevalence of 0.4%. Causes include low-impact trauma in older patients and high-impact trauma in younger patients without pre-existing medical conditions. The aim of this study was to perform a comprehensive evaluation of trauma mechanisms, trauma-promoting factors, comorbidities, medication history and type of surgical care to provide an overview of the causes of injury and the most appropriate therapeutic approach. METHODS In this multicenter cohort study a retrospective analysis of 229 patients who sustained a distal femur fracture between January 2011 and December 2020 was performed. Individual fracture patterns, fracture predisposing factors, concomitant disease profiles, medication history, treatment strategy and associated complications were analyzed. RESULTS 229 patients were included in the retrospective analysis. A total of 113-type 33 A, 50-type 33 B and 66-type 33 C fractures were diagnosed, of whom 92% received a lateral locking plate osteosynthesis. There was a complication in 14.4% of all cases, of which 6.1% were attributable to infection. Significant risk factors for developing a complication were an increased BMI (29.9 ± 8.5 kg/m2; p = 0.04), fracture displacement of over half a shaft width (p < 0.001) and AOC fractures (p < 0,016), specifically C2 fractures (p < 0,008). CONCLUSION In this multicenter retrospective cohort study, lateral locking plate osteosynthesis was the method of choice and was selected in over 90% of cases, regardless of the fracture classification and risk factors. A complication rate of 14.4% emphasizes the necessary analysis of patient- and care-specific risk factors and a resulting adjustment of the therapy strategy. An increased BMI (29.9 ± 8.5 kg/m2; p = 0.04), fracture displacement of over half a shaft width (p < 0.001) and AOC fractures (p < 0,016), specifically C2 fractures (p < 0,008) increase the risk of developing a complication and should prompt an early switch to a treatment strategy that provides more stability.
Collapse
Affiliation(s)
- F Von Rehlingen-Prinz
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - L Eggeling
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany
| | - J Dehoust
- Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany
| | - C Huppke
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - A Strahl
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - M V Neumann-Langen
- Klinikum Konstanz, Department of Orthopaedic and Trauma Surgery, Mainaustrasse 35, 78464 Konstanz, Germany
| | - R Glaab
- Departmet of Traumatology, Cantonal Hospital Aarau, Tellstrasse 25, CH-5001, Aarau, Switzerland
| | - K H Frosch
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Klinikum Hamburg, Bergedorfer Str. 10, 21033 Hamburg, Germany
| | - M Krause
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| |
Collapse
|
10
|
Minhas A, Berkay F, Hudson T, Froehle AW, Horne B, Orr C, Venkatarayappa I, Jerele J. Backout of Distal Interlocking Screws After Retrograde Femoral Nailing With a Novel Device: A Case Series. J Orthop Trauma 2023; 37:500-505. [PMID: 37296090 DOI: 10.1097/bot.0000000000002646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/01/2023] [Indexed: 06/12/2023]
Abstract
OBJECTIVE To report upon a series of patients who have experienced the backout of distal interlocking screws after retrograde femoral nailing with the DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System (DePuy Synthes, Raynham, MA). DESIGN Retrospective case series. PATIENTS Twenty-seven skeletally mature patients with femoral shaft or distal femur fractures who underwent operative fixation with the DePuy Synthes RFN-Advanced Retrograde Femoral Nailing System with 8 patients subsequently experiencing backout of distal interlocking screws. INTERVENTION The study intervention included retrospective review of patient charts and radiographs. MAIN OUTCOME MEASURE The incidence rate of distal interlocking screw backout. RESULTS Thirty percent of patients experienced the backout of at least 1 distal interlocking screw (mean: 1.625) after undergoing retrograde femoral nailing with the RFN-Advanced system. Thirteen total screws backed out postoperatively. Screw backout was identified an average of 61 days postoperatively (range: 30-139 days). All patients complained of implant prominence and pain along the medial or lateral aspect of the knee. Five patients elected to return to the operating room to remove the symptomatic implant. The oblique distal interlocking screws comprised 62% of screw backouts. CONCLUSIONS Given the high incidence rate of this complication, the associated costs of reoperation, and patient discomfort, we believe that a further investigation into this implant complication is warranted. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Arjun Minhas
- Department of Orthopaedic Surgery, Sports Medicine & Rehabilitation, Wright State University Boonshoft School of Medicine, Dayton, OH
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Wang J, Li T, Wu Z, Xu X. Application of a self-made novel less invasive stabilization system for distal femoral fractures. Asian J Surg 2023:S1015-9584(23)01208-3. [PMID: 37625959 DOI: 10.1016/j.asjsur.2023.08.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 08/06/2023] [Indexed: 08/27/2023] Open
Affiliation(s)
- Jingkun Wang
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Hospital of Anhui Medical University, Hefei, 230601, China
| | - Tao Li
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Hospital of Anhui Medical University, Hefei, 230601, China
| | - Zhonghan Wu
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Hospital of Anhui Medical University, Hefei, 230601, China
| | - Xinzhong Xu
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Hospital of Anhui Medical University, Hefei, 230601, China.
| |
Collapse
|
12
|
Elabd MA, Mahmoud AN, Elzaher EH, Kamel ME. Early ambulation and good outcomes after using combined nail plate construct for fixation of distal femoral fractures: a retrospective series of 14 cases. INTERNATIONAL JOURNAL OF BURNS AND TRAUMA 2023; 13:166-172. [PMID: 37736028 PMCID: PMC10509538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Accepted: 07/05/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND Combined nail/plate technique is a relatively novel method for surgically managing distal femur fractures. It was supposed to allow for early weight bearing and achieve adequate fixation that allow for good bone healing. This study aims to describe our single institution experience of treating distal femur fractures using the combined nail/plate technique. METHODOLOGY This is a retrospective study of 14 cases who had AO/OTA fractures 33A_C that were managed with this technique. Patients mean age was 67.6 years and all of them had either obvious osteopenia/osteoporosis or comminuted fractures. RESULTS With early postoperative weight bearing, after a mean follow up of 13.2 months, all the patients were able to return to preinjury activity level. None of the cases were revised for union related problems. Adequate bone healing was noticed after a mean of 16.8 weeks postoperatively. At the final follow up, the mean Oxford knee score was 42 (range 34-46). CONCLUSION The combined nail/plate technique provides adequate fixation method that allows for early weight bearing and good functional outcomes. More studies, ideally comparative are needed to properly assess the cost benefit of this technique compared to other techniques.
Collapse
Affiliation(s)
- Mostafa Aly Elabd
- Department of Orthopedic Surgery, Ain Shams University Faculty of Medicine and University Hospitals Cairo, Egypt
| | - Ahmed Nageeb Mahmoud
- Department of Orthopedic Surgery, Ain Shams University Faculty of Medicine and University Hospitals Cairo, Egypt
| | - Elzaher Hassan Elzaher
- Department of Orthopedic Surgery, Ain Shams University Faculty of Medicine and University Hospitals Cairo, Egypt
| | - Muhammad Elsayed Kamel
- Department of Orthopedic Surgery, Ain Shams University Faculty of Medicine and University Hospitals Cairo, Egypt
| |
Collapse
|
13
|
Zhang JH, Liu H, Cai TY, Lin YZ, Wu J. Resistant distal femoral nonunion treated with combined nail/plate construct and reamer-irrigator-aspirator technique. J Int Med Res 2023; 51:3000605231187945. [PMID: 37498625 PMCID: PMC10387779 DOI: 10.1177/03000605231187945] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/28/2023] Open
Abstract
OBJECTIVE This study was performed to evaluate the effectiveness of intramedullary nailing and a lateral locking plate combined with the reamer-irrigator-aspirator (RIA) bone grafting technique for resistant distal femoral nonunion. METHODS This retrospective observational study was performed from January 2018 to December 2021 and involved five patients who presented with resistant distal femoral nonunion despite undergoing several surgeries. They were treated with intramedullary nailing and a lateral locking plate combined with the RIA bone grafting technique. Postoperative follow-up was performed to observe the healing time, and functional outcomes were evaluated using the Lower Extremity Functional Scale (LEFS). RESULTS After the patients had been monitored for a mean of 17.9 months, complete bone healing was observed in every patient (mean healing time of 4.8 months). Postoperative wound failure in an older patient was successfully treated with resuturing and nutritional assistance. At the last follow-up, the mean LEFS score was 71.2/80 and the mean knee flexion was 109 degrees. CONCLUSIONS Our study demonstrates that combining intramedullary nailing and a lateral locking plate with the RIA bone grafting technique enhances biological properties, provides good structural support, and achieves good union and functional results in the management of resistant nonunion of the distal femur.
Collapse
Affiliation(s)
- Jin-Hui Zhang
- Department of Orthopaedics, the 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - Hui Liu
- Department of Orthopaedics, the 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - Tao-Yi Cai
- Department of Orthopaedics, the 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - Yong-Zhi Lin
- Department of Orthopaedics, the 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| | - Jin Wu
- Department of Orthopaedics, the 909th Hospital, School of Medicine, Xiamen University, Zhangzhou, China
| |
Collapse
|
14
|
Haase DR, Haase LR, Moon TJ, Dallman J, Vance D, Benedick A, Ochenjele G, Napora JK, Wise BT. Perioperative allogenic blood transfusions are associated with increased fracture related infection rates, but not nonunion in operatively treated distal femur fractures. Injury 2023:S0020-1383(23)00383-2. [PMID: 37188588 DOI: 10.1016/j.injury.2023.04.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 04/11/2023] [Accepted: 04/23/2023] [Indexed: 05/17/2023]
Abstract
INTRODUCTION Distal femur fractures are common injuries that remain difficult for orthopedic surgeons to treat. High complication rates, including nonunion rates as high as 24% and infection rates of 8%, can lead to increased morbidity for these patients. Allogenic blood transfusions have previously been identified as risk factors for infection in total joint arthroplasty and spinal fusion surgeries. No studies have explored the relationship between blood transfusions and fracture related infection (FRI) or nonunion in distal femur fractures. METHODS 418 patients with operatively treated distal femur fractures at two level I trauma centers were retrospectively reviewed. Patient demographics were collected including age, gender, BMI, medical comorbidities, and smoking. Injury and treatment information was also collected including open fracture, polytrauma status, implant, perioperative transfusions, FRI, and nonunion. Patients with less than three months of follow up were excluded. RESULTS 366 patients were included in final analysis. One hundred thirty-nine (38%) patients received a perioperative blood transfusion. Forty-seven (13%) nonunions and 30 (8%) FRI were identified. Allogenic blood transfusion was not associated with nonunion (13% vs 12%, P = 0.87), but was associated with FRI (15% vs 4%, P<0.001). Binary logistic regression analysis identified a dose dependent relationship between number of perioperative blood transfusions and FRI: total transfusion ≥2 U PRBC RR= 3.47(1.29, 8.10, P = 0.02), ≥3 RR= 6.99 (3.01, 12.40, P<0.001), and ≥4 RR= 8.94 (4.03, 14.42, P<0.001). DISCUSSION In patients undergoing operative treatment of distal femur fractures, perioperative blood transfusions are associated with increased risk of fracture related infection, but not the development of a nonunion. This risk association increases in a dose-dependent relationship with increasing total blood transfusions received.
Collapse
|
15
|
Cone R, Roszman A, Conway Y, Cichos K, McGwin G, Spitler CA. Risk Factors for Nonunion of Distal Femur Fractures. J Orthop Trauma 2023; 37:175-180. [PMID: 36729004 DOI: 10.1097/bot.0000000000002553] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/13/2022] [Indexed: 02/03/2023]
Abstract
OBJECTIVES To determine patient, fracture, and construct related risk factors associated with nonunion of distal femur fractures. DESIGN Retrospective cohort study. SETTING Academic Level I trauma center. PARTICIPANTS Patients 18 years and older presenting with OTA/AO 33A and 33C distal femur fractures from 2004 to 2020. A minimum follow-up of 6 months was required for inclusion. OTA/AO 33B and periprosthetic fractures were excluded, 438 patients met inclusion criteria for the study. MAIN OUTCOMES The primary outcome of the study was fracture nonunion defined as a return to the OR for management of inadequate bony healing. Patient demographics, comorbidities, injury characteristics, fixation type, and construct variables were assessed for association with distal femur fracture nonunion. Secondary outcomes include conversion to total knee arthroplasty, surgical site infection, and other reoperation. RESULTS The overall nonunion rate was 13.8% (61/438). The nonunion group was compared directly with the fracture union group for statistical analysis. There were no differences in age, sex, mechanism of injury, Injury Severity Score, and time to surgery between the groups. Lateral locked plating characteristics including length of plate, plate metallurgy, screw density, and working length were not significantly different between groups. Increased body mass index [odds ratio (OR), 1.05], chronic anemia (OR, 5.4), open fracture (OR, 3.74), and segmental bone loss (OR, 2.99) were independently associated with nonunion. Conversion to total knee arthroplasty (TKA) ( P = 0.005) and surgical site infection ( P < 0001) were significantly more common in the nonunion group. CONCLUSION Segmental bone loss, open fractures, chronic anemia, and increasing body mass index are significant risk factors in the occurrence of distal femoral nonunion. Lateral locked plating characteristics did not seem to affect nonunion rates. Further investigation into the prevention of nonunion should focus on fracture fixation constructs and infection prevention. LEVEL OF EVIDENCE Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Ryan Cone
- Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL
| | | | | | | | | | | |
Collapse
|
16
|
Buruian A, Carvalho A, Corte Real J, Carvalhais P. Complex distal femoral fracture treated with interfragmentary screws and medial buttress plating. BMJ Case Rep 2022; 15:15/12/e250817. [PMCID: PMC9748934 DOI: 10.1136/bcr-2022-250817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
A woman in her 70s suffered a motor vehicle accident, resulting in an intraarticular, distal femoral fracture with a unique fracture pattern. A 3D-printed model was obtained using the preoperative CT scan for surgical planning. Anatomic reduction was achieved using a medial parapatellar approach and the fracture was fixed with a medial buttress plate and interfragmentary screws. After 18 months, the patient presented a fair Knee Society Score of 62.
Collapse
Affiliation(s)
- Alexei Buruian
- Department of Orthopaedics of Hospital Distrital da Figueira da Foz, Hospital Distrital da Figueira da Foz, Figueira da Foz, Portugal
| | - André Carvalho
- Department of Orthopaedics of Hospital Distrital da Figueira da Foz, Hospital Distrital da Figueira da Foz, Figueira da Foz, Portugal
| | - João Corte Real
- Department of Orthopaedics of Hospital Distrital da Figueira da Foz, Hospital Distrital da Figueira da Foz, Figueira da Foz, Portugal
| | - Pedro Carvalhais
- Department of Orthopaedics of Hospital Distrital da Figueira da Foz, Hospital Distrital da Figueira da Foz, Figueira da Foz, Portugal
| |
Collapse
|
17
|
Wang Y, Zou Q, Wang Z, Wang W, Shen H, Lu H. Micromotion-based balanced drilling technology to increase near cortical strain. BMC Surg 2022; 22:387. [DOI: 10.1186/s12893-022-01816-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 10/11/2022] [Indexed: 11/13/2022] Open
Abstract
Abstract
Objective
A micromotion-based balanced drilling system was designed based on a locking plate (LP) and far cortical locking (FCL) concept to maintain the balance of micromotions of the cortex on both sides of a fracture region. The system was tested by axial compression test.
Methods
The fracture gap was set to 2 cm, and locking screws with a diameter of 5 mm and a locking plate were used to fix it. The diameters of the two sections of the stepping drill were 3.5 mm and 5.0 mm, respectively. One of the matching drilling sleeves was a standard sleeve (eccentricity, 0 mm) and the other was an eccentric sleeve (proximal eccentricity, 1 mm). A model of the fixed locking plate (AO/ASIF 33-A3) for distal femoral fractures with a gap of 2 cm was established based on data from 42 artificial femurs (SAWBONE). According to the shape of the screw holes on the cortex, the fixed fracture models were divided into a control group (standard screw hole group X126, six cases) and an experimental group (elliptical screw hole group N, 36 cases). The experimental group was further divided into six subgroups with six cases in each (N126, N136, N1256, N1356, N12356, N123456), based on the number and distribution of the screws on the proximal fracture segment. The control, N126, and N136 groups were subjected to an axial load of 500 N, and the other groups were subjected to an axial load of 1000 N. The displacements of the kinetic head, far cortex, and near cortex were measured. The integral structural stiffness of the model and the near cortical strain were calculated. The data of each group were analyzed by using a paired t-test.
Results
When the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were 0.96%, 2.35%, and 4.62%, respectively, significantly higher than those in the control group (X126) (p < 0.05). For a different distribution of the screws, when the far cortical strains were 2%, 5%, and 10%, the near cortical strains in group N126 were significantly higher than those in group N136 (p < 0.05). However, there was no significant difference between the near cortical strains in the two groups with four screws (p > 0.05). For different numbers of screws, the near cortical strains in the three-screw groups were significantly higher than those in the four-screw groups (p < 0.05), and there was no significant difference in near cortical strains among the four-, five-, and six-screw groups (p > 0.05).
Conclusion
The proposed drill and matching sleeves enabled a conventional locking compression plate to be transformed into an internal fixation system to improve the balanced motion of the near and far cortices. Thus, strain on a fracture site could be controlled by adjusting the diameter of the drill and the eccentricity of the sleeve.
Collapse
|
18
|
Schmidt C, Riedel C, Stürznickel J, Mushumba H, Delsmann MM, Ries C, Kleiss S, Bannas P, Beil FT, Amling M, Püschel K, Rolvien T, Hubert J. Investigation of distal femur microarchitecture and factors influencing its deterioration: An ex vivo high-resolution peripheral quantitative computed tomography study. J Orthop Res 2022; 40:2057-2064. [PMID: 34985148 DOI: 10.1002/jor.25246] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 11/05/2021] [Accepted: 12/13/2021] [Indexed: 02/04/2023]
Abstract
While fractures of the distal femur are often considered as fragility fractures, detailed knowledge of the bone microarchitecture at this skeletal site is largely unavailable. Initial evaluation of a patient cohort with distal femur fractures showed a markedly increased occurrence in elderly women. The purpose of this study was to determine the extent to which demographic characteristics of distal femur fractures are reflected by general age- and sex-specific variations in local microarchitectural parameters. Fifty cadaveric femora were collected from 25 subjects (12 females, 13 males, age 25-97 years). A volume of interest within 3 cm proximal to the condyles was analyzed using high-resolution peripheral quantitative computed tomography (HR-pQCT), which revealed impaired trabecular and cortical bone microarchitecture in women compared to men as well as in osteoporotic compared to normal or osteopenic subjects, as classified by dual-energy X-ray absorptiometry (DXA) T-score. Linear regression analyzes showed negative associations between age and HR-pQCT parameters in women (e.g., cortical thickness -14 µm/year, 95% CI: -21 to -7 µm/year), but not in men (e.g., cortical thickness 1 µm/year, 95% CI: -12 to 14 µm/year). HR-pQCT parameters showed strong positive associations with areal bone mineral density (aBMD) determined by DXA at the hip in both sexes. Taken together, our findings suggest that female sex, advanced age, and low aBMD represent major risk factors for impaired microarchitecture at the distal femur. Both the diagnostic value of DXA for predicting distal femur fractures and the efficacy of bone-specific agents on fracture risk reduction should be investigated in the future.
Collapse
Affiliation(s)
- Constantin Schmidt
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Christoph Riedel
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Julian Stürznickel
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Herbert Mushumba
- Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Maximilian M Delsmann
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Christian Ries
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Sebastian Kleiss
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Peter Bannas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Frank Timo Beil
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael Amling
- Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Klaus Püschel
- Department of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tim Rolvien
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jan Hubert
- Department of Trauma and Orthopaedic Surgery, Division of Orthopaedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
19
|
Schlatterer DR, Kessler R, Donahue J, Amersi A, Robinson W, Khakharia S. The Ratio of the Distal Femur Width to the Tibial Plateau Width with Advancing Age. J Knee Surg 2022; 35:890-895. [PMID: 33389733 DOI: 10.1055/s-0040-1721125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Historically, intraoperative analysis of knee fracture procedures relied upon a fluoroscopic reduction assessment by the surgeon. This is a subjective assessment due to the lack of linear measurement reference data. Compared with the knee, the ankle and wrist have well-established bony anatomical relationships to guide reduction assessment during fracture treatment. The purpose of this study was to (1) determine the width ratios in the knee (plateau to femur) with aging, and (2) determine knee width changes with aging. One-hundred and fifty consecutive uninjured knee radiographs were reviewed. In all age groups, the width ratio of the articular distal femoral (ADF) to the articular tibial plateau (ATP) is greater than 1.0 and between 1.03 and 1.05. The tibia plateau width is on average 9.34 mm wider and the femoral width is 8.0 mm wider in the 61 to 80 age group than the ATP and the ADF in the younger age groups. In conclusion, the articular tibial plateau width and the articular distal femoral width are nearly equal across ages 20 to 80 years. An absolute articular width value by age cannot be assigned because articular widths change with aging.
Collapse
Affiliation(s)
| | - Raymond Kessler
- Department of Orthopaedic Surgery, Wellstar Atlanta Medical Center, Atlanta, Georgia
| | - Jeffrey Donahue
- Department of Orthopaedic Surgery, Wellstar Atlanta Medical Center, Atlanta, Georgia
| | - Arish Amersi
- Department of Orthopaedic Surgery, Georgia State University, Atlanta, Georgia
| | - Weston Robinson
- Department of Orthopaedic Surgery, Wellstar Atlanta Medical Center, Atlanta, Georgia
| | - Saurabh Khakharia
- Department of Orthopaedic Surgery, Wellstar Atlanta Medical Center, Atlanta, Georgia
| |
Collapse
|
20
|
Kekatpure AL, Khan KK, Kekatpure AL. The Utility of Supracutaneous Plating in the Staged Management of Compound Distal Femur Fracture: A Case Report. Cureus 2022; 14:e24659. [PMID: 35663654 PMCID: PMC9157474 DOI: 10.7759/cureus.24659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/01/2022] [Indexed: 11/27/2022] Open
Abstract
The aim of this report is to draw attention to the use of a vilipend technique ‘supracutaneous plating’ in the management of compound distal femur fractures. Treatment of compound fractures of the distal femur with bone defects and microbial infection remains a challenging task for orthopaedic trauma surgeons. In this case report, we share our experience with the use of the locking distal femoral plate as an external fixator for the staged management of a compound infected distal femur fracture in a 22-year-old male patient. Staged procedures with proper planning give excellent results for infected fractures. Supracutaneous plating can be a viable and patient-friendly alternative in the staged management of compound distal femur fractures instead of the conventional external fixators.
Collapse
|
21
|
Li Y, Zhang ZB, Liu JS, Wu ZM, Sun XC, Zhao YT, Zhang XZ. Analysis of the therapeutic effect of artificial leather embedding combined with fascial sleeve flap transplantation on chronic wounds of lower limbs with bone and plate exposure. BMC Surg 2022; 22:69. [PMID: 35219291 PMCID: PMC8882289 DOI: 10.1186/s12893-022-01521-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Accepted: 02/18/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND After severe trauma of lower limbs, bone, tendon or plate graft exposure is common. The traditional repair method is to use a variety of skin flap transplantation to cover the exposed part, but the wound often can not heal after operation, or the wound is cracked, ulcer, sinus, bone and steel plate are exposed again after wound healing. The reason for this result is that when the flap is covered, the space around the bone plate is not well closed, forming a dead cavity, blood and exudate accumulation, hematoma formation or infection, and finally the wound ruptures again. In addition, due to the swelling and contracture of the flap after operation, the suture tension between the flap and the receiving area becomes larger, the skin becomes thinner and broken, and then the wound is formed. In order to solve the above problems, we carried out the study of artificial true skin embedding combined with fascial sleeve flap transplantation in the treatment of chronic bone plate exposed wounds of lower limbs. METHODS In this paper, 11 cases of chronic wounds with bone exposure and skin necrosis after steel plate implantation were selected. First stage is the wound bed preparation including primary wound expansion, removal of necrotic tissue and incision of sinus wall, removal of deep necrotic bone and fibrotic scarred skin on the outer wall of steel plate to normal tissue on the outer edge of the wound, removal of precipitated peptone and purulent fur in the hole, periphery and bone space of the steel plate, and removal of tendon tissue with basal necrosis and disintegration of the wound. After vacuum sealing drainage (VSD) 1-2 weeks, the peritraumatic basal granulation tissue grew well and there was no necrotic tissue in the wound. In the second stage, the exposed bone was covered with artificial dermis, the steel plate hole or the periphery and the basal space were filled, and the exposed steel plate was completely embedded, and then the fascia sleeve flap was transplanted to cover the wound. The sural neurovascular flap was performed in nine cases and the lateral superior malleolar artery perforator flap in two case. RESULTS The flap survived well in all 11 cases. During the follow-up of 6 months to the removal of the plate, there was no case of rupture, exposure and sinus formation. CONCLUSIONS Artificial dermal covering combined with fascial sleeve flap transplantation can effectively avoid wound dehiscence or sinus formation caused by foreign body retention, infection and flap contracture. It has good effect in repairing chronic wounds with bone plate exposure after severe trauma of lower limbs.
Collapse
Affiliation(s)
- Yong Li
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| | - Zhi-Bo Zhang
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| | - Ji-Song Liu
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China.
| | - Zhu-Min Wu
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| | - Xin-Cheng Sun
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| | - Yu-Tin Zhao
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| | - Xiang-Zhou Zhang
- Department of Burn and Plastic Surgery, Third Hospital of Bengbu, Bengbu, 233000, China
| |
Collapse
|
22
|
Inacio JV, Schwarzenberg P, Yoon R, Kantzos A, Malige A, Nwachuku C, Dailey H. Boundary Conditions Matter - Impact of Test Setup On Inferred Construct Mechanics in Plated Distal Femur Osteotomies. J Biomech Eng 2022; 144:1136733. [PMID: 35171212 DOI: 10.1115/1.4053875] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Indexed: 11/08/2022]
Abstract
The mechanics of distal femur fracture fixation has been widely studied in bench tests that employ a variety of approaches for holding and constraining femurs to apply loads. No standard test methods have been adopted for these tests and the impact of test setup on inferred construct mechanics has not been reported. Accordingly, the purpose of this study was to use finite element models to compare the mechanical performance of a supracondylar osteotomy with lateral plating under conditions that replicate several common bench test methods. A literature review was used to define a parameterized virtual model of a plated distal femur osteotomy in axial compression loading with four boundary condition sets ranging from minimally to highly constrained. Axial stiffness, longitudinal motion, and shear motion at the fracture line were recorded for a range of applied loads and bridge spans. The results showed that construct mechanical performance was highly sensitive to boundary conditions imposed by the mechanical test fixtures. Increasing the degrees of constraint, for example by potting and rigidly clamping one or more ends of the specimen, caused up to a 25x increase in axial stiffness of the construct. Shear motion and longitudinal motion at the fracture line, which is an important driver of interfragmentary strain, was also largely influenced by the constraint test setup. These results suggest that caution should be used when comparing reported results between bench tests that use different fixtures and that standardization of testing methods is needed in this field.
Collapse
Affiliation(s)
- Jordan V Inacio
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| | - Peter Schwarzenberg
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| | - Richard Yoon
- Division of Orthopaedic Trauma, Department of Orthopaedic Surgery, Jersey City Medical Center - RWJBarnabas Health, 377 Jersey Ave, Suite 130, Jersey City, NJ 07302, USA
| | - Andrew Kantzos
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Ajith Malige
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Chinenye Nwachuku
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum, 12 Street, Bethlehem, PA 18015, USA
| | - Hannah Dailey
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA
| |
Collapse
|
23
|
Ward TRW, Garala K, Riemer B. Failure of dual plating in a complex open distal femur fracture as the result of major trauma. BMJ Case Rep 2021; 14:e245362. [PMID: 34853043 PMCID: PMC8638131 DOI: 10.1136/bcr-2021-245362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/14/2021] [Indexed: 11/03/2022] Open
Abstract
A 61-year-old polytrauma patient was admitted with a right distal comminuted metaphyseal femoral fracture with intra-articular extension (Orthopaedic Trauma Association 33C2.3 classification) among other injuries. Due to the high degree of comminution and massive bone loss, this was initially managed with a dual plating open reduction internal fixation. Dual plating has shown to be a superior fixation method than single variable angle locking compression plate (VA-LCP) plating providing greater fixation in metaphyseal bone. Our case reports the failure of dual plating which required removal of metalwork and subsequent fixation using intramedullary nail and plate technique. Failure of dual plating is not well documented in the literature. The most recent radiographs taken 15 months postrevision surgery show that the bone has started to heal with evidence of callus formation.
Collapse
Affiliation(s)
| | - Kanai Garala
- Trauma and Orthopaedics, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Bryan Riemer
- Trauma and Orthopaedics, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| |
Collapse
|
24
|
McArdle C, Louette S, Wilks D, Giannoudis P, Bhat W. Distally Based Sartorius Flap for Soft Tissue Coverage of the Distal Femur. Strategies Trauma Limb Reconstr 2021; 16:120-122. [PMID: 34804229 PMCID: PMC8578243 DOI: 10.5005/jp-journals-10080-1521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
This case report outlines the use of the distal pedicle of the sartorius muscle in the coverage of a large bony and soft tissue defects of the distal femur in a trauma setting. How to cite this article: McArdle C, Louette S, Wilks D, et al. Distally Based Sartorius Flap for Soft Tissue Coverage of the Distal Femur. Strategies Trauma Limb Reconstr 2021;16(2):120–122.
Collapse
Affiliation(s)
- Ciarstan McArdle
- Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospital Trust, Leeds, West Yorkshire, United Kingdom
| | - Stefan Louette
- Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospital Trust, Leeds, West Yorkshire, United Kingdom
| | - Daniel Wilks
- Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospital Trust, Leeds, West Yorkshire, United Kingdom
| | - Peter Giannoudis
- Department of Trauma and Orthopaedic Surgery, Leeds Teaching Hospital Trust, Leeds, West Yorkshire, United Kingdom
| | - Waseem Bhat
- Department of Plastic and Reconstructive Surgery, Leeds Teaching Hospital Trust, Leeds, West Yorkshire, United Kingdom
| |
Collapse
|
25
|
Mansouri-Tehrani MM, Yavari P, Moosayii D, Eslami S, Nourian SMA. Evaluation of femoral malrotation after intramedullary nailing. INTERNATIONAL JOURNAL OF BURNS AND TRAUMA 2021; 11:418-423. [PMID: 34858723 PMCID: PMC8610817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Accepted: 08/06/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND Intramedullary nailing and closed reduction are one of the most important treatment strategies for femoral shaft fractures. Malrotation in the femoral shaft is a complication that requires exact investigations. Here we aimed to evaluate and report the outcomes of malrotation of femur in patients with femoral shaft fractures following antegrade intramedullary nailing. METHODS In this cross-sectional study, 140 patients who had referred to Shahid-Beheshti Hospital in Abadan, Iran and had undergone antegrade intramedullary fixation for isolated femoral shaft fracture during a 6-year period from 2015 to 2021 were enrolled. Demographic information and disease-related information were collected. During operation, the patients were assessed clinically for malrotation of femur with 90° of the knee flection and with the hip in 0° flexion and then in the postoperative follow-up period, the patient was examined again and a computed tomography scan requested to identify the degree of malrotation of femur and the observers were unaware of the CT scan result at the time of the clinical examination. We also measured the amount of internal and external rotation while the patient in the lying supine position with 90° flexion in the knee and hip joint and lying prone position with hip extension. In CT imaging to determine the amount of malrotation of femur, the angle between a line drawn across the two femoral condyles in the posterior aspect and the femoral neck shows the amount of rotation. RESULTS Degree of rotational deformity, less than 5°, 5 to 10° and 10 to 15° was less than 8.6%, 75.7% and 15.7% respectively and did not relate to age, sex, fracture location and activity of the patients (P>0.05). There was a strong linear correlation with the average predictive power between clinically detected torsional deformity in comparison with the CT detected torsional deformity (r=0.333 and P=0.005), which was stronger in women than men (r=0.336 in men and r=0.659 in women) (P<0.05). There was a strong linear correlation with the average predictive power between clinically detected torsional deformity in comparison with the CT detected torsional deformity was observed only in external malrotation of femur (r=0.541 and P=0.001). A poor inverse linear relationship was observed between clinically detected and CT detected torsional deformity with the age of the patients which the correlation of clinically detected was more than the CT detected (r in clinical examination =-0.285 and r in CT measurement =-0.246) (P<0.05). CONCLUSION In this study, there was no femoral malrotation over 15° that was associated with clinical symptoms. However, a CT scan should be performed for accurate diagnosis and necessary measures but it does not seem necessary to perform in all patients.
Collapse
Affiliation(s)
| | - Pedram Yavari
- Department of Orthopedics, School of Medicine, Isfahan University of Medical SciencesIsfahan, Iran
| | | | - Sepehr Eslami
- Department of Orthopedic Surgery, Abadan Faculty of Medical ScienceAbadan, Iran
| | | |
Collapse
|
26
|
Meccariello L, Bisaccia M, Ronga M, Falzarano G, Caraffa A, Rinonapoli G, Grubor P, Pace V, Rollo G. Locking retrograde nail, non-locking retrograde nail and plate fixation in the treatment of distal third femoral shaft fractures: radiographic, bone densitometry and clinical outcomes. J Orthop Traumatol 2021; 22:33. [PMID: 34350532 PMCID: PMC8339178 DOI: 10.1186/s10195-021-00593-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2019] [Accepted: 07/24/2021] [Indexed: 12/02/2022] Open
Abstract
BACKGROUND Distal third femoral shaft fractures are characterized by increasing incidence and complexity and are still considered a challenging problem (high morbidity and mortality). No consensus on best surgical option has been achieved. This study aims to investigate radiographic, mineral bone densitometry and clinical outcomes of locking retrograde intramedullary (LRN) nailing, non-locking retrograde intramedullary nailing and anatomical locking plate to surgically treat distal third femoral shaft fractures in young adults. Our hypothesis was that there is no significant statistical difference among the surgical options in terms of results (radiographic, bone densitometry and outcomes assessment). METHODS Retrospective study: 90 patients divided into three groups (group 1 LRN, group 2 NLRN, group 3 plating). Average age was respectively 42.67 (± 18.32), 44.27 (± 15.11) and 42.84 (± 18.32) years. Sex ratio F:M was respectively 2.75, 2.33 and 2.00. AO Classification, KOOS, NUSS and RUSH score, VAS, DEXA scans and plain radiographs were used. Evaluation endpoint: 12 months after surgery. RESULTS There were no statistical differences in terms of surgery time, transfusions, and wound healing. Results were similar with regard to average time of bone healing, RUSH scores, VAS, KOOS, regression between RUSH and VAS, average correlation clinical-radiographic results and patients outcomes. CONCLUSIONS Our results showed no statistical difference in the use of LNR, NLNR and plating for treatment of distal third femur shaft fractures in terms of radiographic, bone densitometry and clinical outcomes. Good subjective and objective results are provided by all three techniques. The choice among the studied techniques must be based on surgeons' experience, indications and subjective patients' aspects. The absence of relevant similar data in the published literature does not allow definitive validation (or rejection) of our hypothesis. A more powered study with a bigger cohort is needed for definitive validation.
Collapse
Affiliation(s)
- Luigi Meccariello
- Department of Orthopedics and Traumatology, AORN San Pio, Via Cupa dell'Angelo, Block: Moscati Floor:2, 82100, Benevento, Italy.
| | - Michele Bisaccia
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Mario Ronga
- Orthopaedic and Trauma Operative Unit, Department of Biomedical and Dental Sciences and Morpho-Functional Imaging, University of Messina, University Hospital G. Martino, Messina, Italy
| | - Gabriele Falzarano
- Department of Orthopedics and Traumatology, Azienda Ospedaliera "Gaetano Rummo", Benevento, Italy
| | - Auro Caraffa
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Giuseppe Rinonapoli
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
| | - Predrag Grubor
- School of Medicine, University of Banja Luka, Banja Luka, Bosnia and Herzegovina
| | - Valerio Pace
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria Della Misericordia" Hospital, Perugia, Italy
- Orthopaedic and Trauma Operative Unit, Department of Biomedical and Dental Sciences and Morpho-Functional Imaging, University of Messina, University Hospital G. Martino, Messina, Italy
- Department of Orthopedics and Traumatology, Azienda Ospedaliera "Gaetano Rummo", Benevento, Italy
- School of Medicine, University of Banja Luka, Banja Luka, Bosnia and Herzegovina
- The Royal National Orthopaedic Hospital, Stanmore, London, UK
| | - Giuseppe Rollo
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| |
Collapse
|
27
|
Jain S, Lamb J, Townsend O, Scott CEH, Kendrick B, Middleton R, Jones SA, Board T, West R, Pandit H. Risk factors influencing fracture characteristics in postoperative periprosthetic femoral fractures around cemented stems in total hip arthroplasty : a multicentre observational cohort study on 584 fractures. Bone Jt Open 2021; 2:466-475. [PMID: 34233455 PMCID: PMC8325979 DOI: 10.1302/2633-1462.27.bjo-2021-0027.r1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Aims This study evaluates risk factors influencing fracture characteristics for postoperative periprosthetic femoral fractures (PFFs) around cemented stems in total hip arthroplasty. Methods Data were collected for PFF patients admitted to eight UK centres between 25 May 2006 and 1 March 2020. Radiographs were assessed for Unified Classification System (UCS) grade and AO/OTA type. Statistical comparisons investigated relationships by age, gender, and stem fixation philosophy (polished taper-slip (PTS) vs composite beam (CB)). The effect of multiple variables was estimated using multinomial logistic regression to estimate odds ratios (ORs) with 95% confidence intervals (CIs). Surgical treatment (revision vs fixation) was compared by UCS grade and AO/OTA type. Results A total of 584 cases were included. Median age was 79.1 years (interquartile range 72.0 to 86.0), 312 (53.6%) patients were female, and 495 (85.1%) stems were PTS. The commonest UCS grade was type B1 (278, 47.6%). The most common AO/OTA type was spiral (352, 60.3%). Metaphyseal split fractures occurred only with PTS stems with an incidence of 10.1%. Male sex was associated with a five-fold reduction in odds of a type C fracture (OR 0.22 (95% CI 0.12 to 0.41); p < 0.001) compared to a type B fracture. CB stems were associated with significantly increased odds of transverse fracture (OR 9.51 (95% CI 3.72 to 24.34); p < 0.001) and wedge fracture (OR 3.72 (95% CI 1.16 to 11.95); p = 0.027) compared to PTS stems. Both UCS grade and AO/OTA type differed significantly (p < 0.001 and p = 0.001, respectively) between the revision and fixation groups but a similar proportion of B1 fractures underwent revision compared to fixation (45.3% vs 50.6%). Conclusion The commonest fracture types are B1 and spiral fractures. PTS stems are exclusively associated with metaphyseal split fractures, but their incidence is low. Males have lower odds of UCS grade C fractures compared to females. CB stems have higher odds of bending type fractures (transverse and wedge) compared to PTS stems. There is considerable variation in practice when treating B1 fractures around cemented stems. Cite this article: Bone Jt Open 2021;2(7):466–475.
Collapse
Affiliation(s)
- Sameer Jain
- University of Leeds, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | - Jonathan Lamb
- University of Leeds, Leeds, UK.,Chapel Allerton Hospital, Leeds, UK
| | | | | | - Ben Kendrick
- Nuffield Orthopaedic Centre, Oxford University Hospitals, Oxford, UK
| | | | | | | | | | - Hemant Pandit
- Chapel Allerton Hospital, Leeds, UK.,University of Leeds, Leeds, UK
| |
Collapse
|
28
|
Ghouri SI, Asim M, Mustafa F, Kanbar A, Ellabib M, Al Jogol H, Muneer M, Abdurraheim N, Goel AP, Abdelrahman H, Al-Thani H, El-Menyar A. Patterns, Management, and Outcome of Traumatic Femur Fracture: Exploring the Experience of the Only Level 1 Trauma Center in Qatar. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18115916. [PMID: 34072990 PMCID: PMC8198965 DOI: 10.3390/ijerph18115916] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Revised: 05/24/2021] [Accepted: 05/27/2021] [Indexed: 11/16/2022]
Abstract
Background: Femur is the most fractured long bone in the body that often necessitates surgical fixation; however, data on the impact of the mechanism of injury (MOI), age, and timing of intervention are lacking in our region of the Arab Middle East. We aimed to describe the patterns, management, and outcome of traumatic femoral shaft fractures. Methods: A retrospective descriptive observational study was conducted for all trauma patients admitted with femoral shaft fractures between January 2012 and December 2015 at the only level 1 trauma center and tertiary hospital in the country. Data were analyzed and compared according to the time to intervention (intramedullary nailing; IMN), MOI, and age groups. Main outcomes included in-hospital complications and mortality. Results: A total of 605 hospitalized cases with femur fractures were reviewed. The mean age was 30.7 ± 16.2 years. The majority of fractures were unilateral (96.7%) and 91% were closed fractures. Three-fourths of fractures were treated by reamed intramedullary nailing (rIMN), antegrade in 80%. The pyriform fossa nails were used in 71.6% while trochanteric entry nails were used in 28.4%. Forty-five (8.9%) fractures were treated with an external fixator, 37 (6.1%) had conservative management. Traffic-related injuries occurred more in patients aged 14–30 years, whereas fall-related injuries were significantly higher in patients aged 31–59. Thirty-one patients (7.8%) had rIMN in less than 6 h post-injury, 106 (25.5%) had rIMN after 6–12 h and 267 (66.8%) had rIMN after more than 12 h. The implant type, duration of surgery, DVT prophylaxis, in-hospital complications, and mortality were comparable among the three treatment groups. Conclusions: In our center, the frequency of femoral fracture was 11%, and it mainly affected severely injured young males due to traffic-related collisions or falls. Further multicenter studies are needed to set a consensus for an appropriate management of femur fracture based on the MOI, location, and timing of injury.
Collapse
Affiliation(s)
- Syed Imran Ghouri
- Department of Surgery, Orthopedic Surgery, Hamad General Hospital, Doha, Qatar;
| | - Mohammad Asim
- Clinical Research, Trauma and Vascular Surgery, Hamad General Hospital, Doha, Qatar;
| | - Fuad Mustafa
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Ahad Kanbar
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Mohamed Ellabib
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Hisham Al Jogol
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Mohammed Muneer
- Department of Surgery, Plastic Surgery, Hamad General Hospital, Doha, Qatar;
| | - Nuri Abdurraheim
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Atirek Pratap Goel
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Husham Abdelrahman
- Department of Surgery, Trauma Surgery, Hamad General Hospital, Doha, Qatar; (F.M.); (A.K.); (M.E.); (H.A.J.); (N.A.); (A.P.G.); (H.A.)
| | - Hassan Al-Thani
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Doha, Qatar;
| | - Ayman El-Menyar
- Clinical Research, Trauma and Vascular Surgery, Hamad General Hospital, Doha, Qatar;
- Department of Clinical Medicine, Weill Cornell Medical College, Doha, Qatar
- Correspondence: ; Tel.: +974-44396130
| |
Collapse
|
29
|
Davis S, Olaussen A, Bowles KA, Shannon B. Review article: Paramedic pain management of femur fractures in the prehospital setting: A systematic review. Emerg Med Australas 2021; 33:601-609. [PMID: 33982421 DOI: 10.1111/1742-6723.13793] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 04/13/2021] [Accepted: 04/20/2021] [Indexed: 01/05/2023]
Abstract
Femur shaft and neck of femur (NOF) fractures are often undertreated in the prehospital setting. These injuries can present unique clinical and logistical concerns in the prehospital setting. This systematic review aimed to investigate paramedic prehospital pain management of patients who had suffered NOF or femur fractures, and to investigate which interventions are effective. A systematic review was conducted in line with Preferred Reporting Item for Systematic Reviews and Meta-Analyses guidelines. Four databases were searched from inception date 23 March 2020. Articles were independently reviewed by two authors and conflicts resolved by a third author, followed by a hand search of the included reference lists. References were included if they addressed paramedic interventions for NOF or femur shaft fractures. Outcomes of interest were the effectiveness and complications of different modalities administered by paramedics. The search yielded 6868 articles, of which 19 met the final inclusion criteria. Studies investigated a variety of interventions including traction splints, intravenous (IV) analgesia and alternative analgesic options. Traction splinting and IV analgesia were consistently reported as underutilised. Alternative analgesics such as auricular acupressure, transcutaneous electrical nerve stimulation (TENS) and fascia iliaca compartment block were found to be effective techniques that could be safely and competently employed by paramedics, reducing pain for patients with limited adverse events. NOF and femur shaft fractures are an undertreated injury in the prehospital setting. Traction splinting and IV analgesia remain the traditional methodologies of treatment for these injuries; however, there are alternatives such as TENS, auricular acupressure and fascia iliaca compartment block that appear to be emerging as safe and effective options for the prehospital setting.
Collapse
Affiliation(s)
- Samantha Davis
- Department of Paramedicine, Monash University, Melbourne, Victoria, Australia.,Ambulance Victoria, Melbourne, Victoria, Australia
| | - Alexander Olaussen
- Department of Paramedicine, Monash University, Melbourne, Victoria, Australia.,Ambulance Victoria, Melbourne, Victoria, Australia.,National Trauma Research Institute, The Alfred, Melbourne, Victoria, Australia.,Emergency Department, Northeast Health Wangaratta, Wangaratta, Victoria, Australia
| | - Kelly-Ann Bowles
- Department of Paramedicine, Monash University, Melbourne, Victoria, Australia
| | - Brendan Shannon
- Department of Paramedicine, Monash University, Melbourne, Victoria, Australia.,Ambulance Victoria, Melbourne, Victoria, Australia
| |
Collapse
|
30
|
Lemsanni M, Najeb Y. Outcomes of distal femoral fractures treated with dynamic condylar screw (DCS) plate system: a single centre experience spanning 15 years. Pan Afr Med J 2021; 38:363. [PMID: 34367442 PMCID: PMC8308866 DOI: 10.11604/pamj.2021.38.363.27524] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Accepted: 04/07/2021] [Indexed: 11/12/2022] Open
Abstract
Introduction the dynamic condylar screw (DCS) plate is an angular stable fixation (95°) system for distal femur fractures that allows for the ability to apply compression across the femoral condyles. The aim of this study was to evaluate our experience treating distal femur fractures with this device and give the long-term outcome. Methods a retrospective study was undertaken in our institution during the period from January 2002 to December 2016. A total number of 240 patients with distal femur fractures were managed using DCS plate system and included in the study. The mean follow-up period was 33 months (26 - 62 months). Clinico-radiological progression of fracture union as well as the functional outcome was studied. Results most of the fractures were closed injuries in young male patients resulting from traffic accidents. The average time to union was 12.6 weeks (range 11 - 23). Eight patients (3.3%) suffered superficial infection. Five patients (2.1%) developed deep venous thrombosis. Delayed union was observed in nine cases (3.7%) and non union in six cases (2.5%). At final follow-up, the mean range of motion (ROM) of knee was 115.7° (100°-148°). The mean Knee Society Score (KSS) was 84.5 (59 - 94) and the mean Lysholm score was 88.6 (range, 61 - 96), translating to good clinical results. Conclusion our study conclusively establishes that excellent functional outcome can be achieved with DCS plate inserted with skilled surgical technique in distal femur fractures including the ones that are communited or occurring in osteoporotic bone with a negligible complication rates.
Collapse
Affiliation(s)
- Meryem Lemsanni
- Department of Orthopaedic and Trauma Surgery, Ibn Tofail Hospital, Mohammed VI University Hospital Center, Abdelouahab Derraq Street, PB 40000, Marrakesh, Morocco
| | - Youssef Najeb
- Department of Orthopaedic and Trauma Surgery, Ibn Tofail Hospital, Mohammed VI University Hospital Center, Abdelouahab Derraq Street, PB 40000, Marrakesh, Morocco
| |
Collapse
|
31
|
Siddiqui YS, Mohd J, Abbas M, Gupta K, Khan MJ, Istiyak M. Technical difficulties and mechanical failure of distal femoral locking compression plate (DFLCP) in management of unstable distal femoral fractures. INTERNATIONAL JOURNAL OF BURNS AND TRAUMA 2021; 11:9-19. [PMID: 33824780 PMCID: PMC8012867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 12/18/2020] [Indexed: 06/12/2023]
Abstract
Objective of the paper is to portray the technical difficulties and mechanical failure of Distal Femoral Locking Compression Plate in the management of unstable distal femoral fractures. The primary outcome measure was defined as revision surgery due to implant failure with subsequent non-union. Secondary outcome measures were mal-union, delayed union, peri-implant fracture and infection. Functional outcome were evaluated using Schatzker & Lambert criteria. Thirty nine patients were available for final follow up. The rate of revision surgery as primary outcome measure was 7.69%. Mal-union was seen in 5.1%, delayed union in 7.69%, superficial infection in 10.25% and deep infection in 5.1% patients. All except three fractures united following index surgery. Functional outcome as per the Schatzker & Lambert Criteria was excellent in 20.5%, good in 48.7%, fair in 18% and failure in 12.8%. In sight of the findings of our study along with existing literature we propose for creating a fixation construct that is conducive for fracture healing by following principles of locking compression plating and augmenting stability by medial column reconstruction.
Collapse
|
32
|
Abstract
The reported levels of non-union in the lateral locking plate differ widely, with some early studies showing rates of less than 6% and up to 17%-21% in more recent studies. We report a case where better results were shown by a non-union treated with distal femoral nailing with allogenic grafting.
Collapse
Affiliation(s)
- Kishore Vellingiri
- Orthopaedics, Sri Devaraj Urs Academy of Higher Education and Research, Kolar, IND
| | - Nagakumar J S
- Orthopaedics, Sri Devaraj Urs Academy of Higher Education and Research, Kolar, IND
| |
Collapse
|
33
|
Unim B, Minelli G, Da Cas R, Manno V, Trotta F, Palmieri L, Galluzzo L, Maggi S, Onder G. Trends in hip and distal femoral fracture rates in Italy from 2007 to 2017. Bone 2021; 142:115752. [PMID: 33188958 DOI: 10.1016/j.bone.2020.115752] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 10/20/2020] [Accepted: 11/09/2020] [Indexed: 02/08/2023]
Abstract
Osteoporosis-related fractures are a growing public health concern worldwide due to high societal and economic burden. The study aims to assess trends in incidence rates of hip and distal femoral fractures and in the use of anti-osteoporosis drugs in Italy between 2007 and 2017. Patients with hip and distal femoral fractures (ICD-9-CM codes 820.x and 821.x) were identified in the Italian National Hospital Discharge Database while anti-osteoporosis medication data were retrieved from the National Observatory on the Use of Medicines Database. A joinpoint regression analysis was performed to identify the years where the trends in incidence rates of hip and distal femoral fractures changed significantly; the average annual percentage change for the period of observation was estimated. Hospitalizations for femoral fractures were 991,059, of which 91.4% were hip fractures and 76.5% occurred in women. Age-standardized hip fractures rate per 100,000 person-years decreased both in women (-8.7%; from 789.9 in 2007 to 721.5 in 2017) and in men (-4.3%; from 423.9 to 405.6), while the rate of distal femoral fractures increased by 23.9% in women (from 67.78 to 83.95) and 22.7% in men (from 27.76 to 34.06). These changes were associated with an increment in the use of anti-osteoporosis drugs from 2007 to 2011 (from 9.1 to 12.4 DDD/1000 inhabitants/day), followed by a plateau in the period 2012-2017. The use of bisphosphonates increased progressively from 2007 to 2010 (from 8.2 to 10.5 DDD/1000 inhabitants/day), followed by a plateau and then decreased from 2015 onwards. The decreasing trend of hip fractures could be related to a major intake of anti-osteoporosis medications while the increment of distal femoral fractures might be due to population aging and to the use of bisphosphonates and denosumab. Further research is needed to identify and implement interventions to prevent hip and distal femoral fractures.
Collapse
Affiliation(s)
- Brigid Unim
- Department of Cardiovascular, Endocrine-metabolic Diseases and Aging, Istituto Superiore di Sanità, Rome, Italy.
| | - Giada Minelli
- Service of Statistics, Istituto Superiore di Sanità, Rome, Italy
| | - Roberto Da Cas
- National Centre for Drug Research and Evaluation, Istituto Superiore di Sanità, Rome, Italy
| | - Valerio Manno
- Service of Statistics, Istituto Superiore di Sanità, Rome, Italy
| | | | - Luigi Palmieri
- Department of Cardiovascular, Endocrine-metabolic Diseases and Aging, Istituto Superiore di Sanità, Rome, Italy
| | - Lucia Galluzzo
- Department of Cardiovascular, Endocrine-metabolic Diseases and Aging, Istituto Superiore di Sanità, Rome, Italy
| | | | - Graziano Onder
- Department of Cardiovascular, Endocrine-metabolic Diseases and Aging, Istituto Superiore di Sanità, Rome, Italy
| |
Collapse
|
34
|
[Distal femoral fractures in geriatric patients : Does time to surgery affect revision and mortality?]. Unfallchirurg 2020; 124:568-573. [PMID: 33119793 DOI: 10.1007/s00113-020-00914-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/07/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND For proximal femoral fractures the time to surgery has been reported to influence the mortality rate. To date, detailed analyses in geriatric patients with distal femoral fractures are not available. MATERIAL AND METHODS A monocentric study with retrospective data retrieved from an electronic database was performed. The study included distal femoral fractures with surgical treatment between 2006 and 2017 in patients aged 65 years and older. A total of ten variables were evaluated and two outcome measures were investigated: revision and mortality in relation to time of surgery within 24 h or later. The minimum follow-up was 2 years. For patients who were still alive the Parker score was calculated. The null hypothesis was that time to surgery does not affect revision and mortality. RESULTS A total of 57 consecutive patients with 60 fractures and an average age of 82.5 years (65-97 years) were included. Most of the fractures were supracondylar (n = 42). All but three fractures were treated with internal fixation. The revision rate was 17.5% (peri-implant fractures n = 4, infections n = 2, non-union n = 2, impaired wound healing n = 2 and secondary dislocation n = 1). The 1‑year mortality rate was 20%. No significant effects on revision (p = 0.414) and survival rate (log rank 0.175) were observed for patients treated within 24 h or later. After a mean postoperative period of 5.5 years, the mean Parker score for 18 living patients was 5.9. CONCLUSION Time to surgery demonstrated no significant effects with respect to revision and mortality. Multicenter studies are absolutely necessary to increase the sample size and statistical power.
Collapse
|
35
|
Yuan Y, Luo B, Hao Q, Yuan J, Qu GB, Hao PD, Zeng ZJ, Yang JF, Xu ZJ. Clinical outcomes of revision with retrograde intermedullary nailing for failed plating of distal femoral fractures: a retrospective study. INTERNATIONAL ORTHOPAEDICS 2020; 44:2437-2442. [PMID: 32654056 DOI: 10.1007/s00264-020-04621-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Accepted: 05/12/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To assess the feasibility and effectiveness of retrograde intramedullary nail (RIN) revision surgeries for locking compression plate (LCP) failure in distal femoral fractures. METHODS This retrospective study included 13 patients who suffered from metalwork failures after they initially underwent open reduction and LCP fixation. In patients who eventually underwent RIN revision from January 2014 to December 2016, range of motion (ROM) and Hospital for Special Surgery (HSS) scores obtained before surgery and at the final follow-up time were analysed. RESULTS The average operative time was 155 minutes (range, 120-210 minutes), and the average blood loss volume was 650 ml (range, 200-1350 ml). There were two cases of complications (15.38%): one was calf muscle vein thrombosis, and the other was a superficial infection. No deep tissue infection or deep vein thrombosis was observed post-operatively. The average follow-up time was 16 months (range, 12-24 months). All fractures healed in a mean of 6.5 months (range, 4-12 months), and one patient underwent an additional bone graft surgery that did not involve a bone graft during the RIN revision operation (this eventually healed at 12 months post-operatively). The mean ROM before the operation was 86.92 ± 12.34°. At the final follow-up, the mean ROM was 112.69 ± 9.27°. There was a significant difference between pre-operative and post-operative ROM (P < 0.01). The mean HSS score improved significantly from 38.85 ± 9.62 points pre-operatively to 79.62 ± 5.42 points post-operatively. There was a significant difference between pre-operative and post-operative HSS scores (P < 0.01). CONCLUSIONS RIN revision surgery achieved excellent clinical results in patients with LCP failure.
Collapse
Affiliation(s)
- Yi Yuan
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Bing Luo
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Qi Hao
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Jun Yuan
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Gang-Bo Qu
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Pan-Deng Hao
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Zhi-Jiang Zeng
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China
| | - Jia-Fu Yang
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China.
| | - Zu-Jian Xu
- Department of Orthopaedics, Traditional Chinese Medicine Hospital, Southwest Medical University, 182# Chunhui Road, Luzhou, 646000, Sichuan, People's Republic of China.
| |
Collapse
|
36
|
Rollo G, Bisaccia M, Rinonapoli G, Caraffa A, Pace V, Irimia JC, de Cruto E, Bisaccia O, Pica G, Tarantino D, Meccariello L. Radiographic, Bone Densitometry and Clinic Outcomes Assessments in Femoral Shaft Fractures Fixed by Plating or Locking Retrograde Nail. Med Arch 2020; 73:195-200. [PMID: 31404125 PMCID: PMC6643321 DOI: 10.5455/medarh.2019.73.195-200] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Introduction: Distal femoral shaft fractures are characterized by increasing incidence and complexity and are still considered a challenging problem (high morbidity and mortality). No consensus on best surgical option has been achieved. Aim: This study aims is to investigate radiographic, mineral bone densitometry and clinical outcomes of locking retrograde intramedullary (LRN) nailing and anatomical locking plate to surgically treat distal femoral shaft fractures in young adults based on the hypothesis that there is no statistical difference among the two surgical options in terms of results (radiographic, bone densitometry and outcomes assessment). Methods: Retrospective study: 30 patients divided into 2 groups (Group 1 LRN, Group 2 Nailing). Average age was 42.67±18.32 for Group 1 and 42.84 ±18.32 for Group 2 (range of age 18-65 for both groups). Gender Ratio (male: female) was 2.75 (11:4) for both Group 1 and 2. AO Classification, NUSS and RUSH score, VAS, Dexa scans, plain radiographs were used. Evaluation endpoint: 12 months after surgery (mean follow up 16.24). Results: No statistical difference in terms of surgery time, transfusions, wound healing. Similar results with regard to average time of bone healing, RUSH scores, VAS, regression between RUSH and VAS, average correlation clinical-radiographic results and patients outcomes. Only one patient of each group had reduction of mineral bone densitometry values. Conclusion: No statistical difference about the use of LNR or Nailing for treatment of distal femur shaft fractures in terms of radiographic, bone densitometry and outcomes has been found accordingly to our results. Good subjective and objective results are provided by both techniques. The choice among the two techniques must be based on surgeons’ experience, indications and subjective patients’ aspects. The absence of relevant similar data in the published literature does not allow definitive validation (or rejection) of our hypothesis. A more powered study with bigger cohort is needed for definitive validation.
Collapse
Affiliation(s)
- Giuseppe Rollo
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| | - Michele Bisaccia
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria della Misericordia" Hospital, Perugia, Italy
| | - Giuseppe Rinonapoli
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| | - Auro Caraffa
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| | - Valerio Pace
- Division of Orthopedics and Trauma Surgery, University of Perugia, "S. Maria della Misericordia" Hospital, Perugia, Italy.,The Royal National Orthopaedic Hospital, Stanmore, London, United Kingdom
| | - Javier Cervera Irimia
- Orthopaedic Surgery and Traumatology Department, Villalba General Hospital, Madrid, Spain
| | - Enio de Cruto
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| | - Olga Bisaccia
- Unit of Radiology, San Carlo Hospital", Potenza, Italy
| | - Giuseppe Pica
- Department of Orthopedics and Traumatology, AO San Pio-G.Rummo, Benevento Italy
| | | | - Luigi Meccariello
- Department of Orthopedics and Traumatology, Vito Fazzi Hospital, Lecce, Italy
| |
Collapse
|
37
|
Consigliere P, Iliopoulos E, Ads T, Trompeter A. Early versus delayed weight bearing after surgical fixation of distal femur fractures: a non-randomized comparative study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2019; 29:1789-1794. [PMID: 31267203 DOI: 10.1007/s00590-019-02486-4/tables/3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 06/27/2019] [Indexed: 05/25/2023]
Abstract
Distal femur fractures are rare injuries with a bimodal distribution (high-energy injury in young males and low-energy fragility fractures in old females). Their management can be challenging: open reduction and internal fixation (ORIF) with distal femur locking plates is a commonly performed procedure especially in comminuted fractures with articular involvement. Anxiety regarding the stability of the fixation, especially in osteoporotic bone, leads to post-operative restrictive instructions with limitations regarding the weight-bearing status. Early weight bearing (EWB), however, was shown to enhance bone healing and was not correlated with an increased risk of fracture displacement or implant failure in previous published studies, which reported the results of proximal femur, tibia and ankle fractures surgical treatment. The current study analysed the results of a series of distal femur fractures (51 patients, mean age 64.3 ± 20.7) all treated with ORIF in a level-I major trauma centre, but differently rehabilitated. Group A was, in fact, instructed not to weight bear or to touch weight bear, while group B started to weight bear soon after surgery without specific restrictions. The objective was to compare the outcome and the complication rate in the two groups at 6 and 12 weeks after surgery. The results showed no statistically significant differences in the two groups and no post-operative complications in the EWB group. Six complications were observed in the non-weight-bearing group (four fractures displacement and two implants failure at 12-week follow-up). Distal femur fractures treated with locking plates can be rehabilitated with EWB to allow early return to function. There is no evidence that EWB increases the risk of fracture displacement or implant failure in distal femur fractures treated with distal locking plates. Instead, it is possible that post-operative non-weight-bearing status delays the fracture-healing process increasing the risk of failure of the fixation.
Collapse
Affiliation(s)
- Paolo Consigliere
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK.
| | - Efthymios Iliopoulos
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| | - Tamer Ads
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| | - Alex Trompeter
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| |
Collapse
|
38
|
Wang MT, An VVG, Sivakumar BS. Non-union in lateral locked plating for distal femoral fractures: A systematic review. Injury 2019; 50:1790-1794. [PMID: 31324342 DOI: 10.1016/j.injury.2019.07.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Revised: 06/25/2019] [Accepted: 07/08/2019] [Indexed: 02/02/2023]
Abstract
INTRODUCTION This study aims to identify patient and intra-operative factors that contribute to non-union in locked lateral plating for distal femoral fractures. METHODS Systematic searches of English-language articles in Ovid Medline, PubMed, Embase, Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews were undertaken in February 2018 according to the PRISMA guidelines. The search terms were (fracture or fracture*) AND (distal femur or distal femoral) AND (malunion or non-union). Eligible studies published at any time reported non-union rates and compared patient and intraoperative factors in patients who underwent locked lateral plating for traumatic distal femoral fractures. The quality of included papers was assessed using The Journal of Bone and Joint Surgery levels of evidence (Wright et al., 2003), and further appraised using the Downs and Black score (Downs and Black, 1998). RESULTS Eight studies investigating 1380 distal femoral fractures were found to satisfy the inclusion and exclusion criteria. These studies analysed a variety of patient and intra-operative factors that may contribute to non-union. These include high BMI, open fracture, comminution, fracture infection, stainless steel plate material, shorter working length, open reduction and internal fixation when compared with minimally invasive plate osteosynthesis, high construct rigidity scores and purely locking screw constructs. CONCLUSION This review has identified multiple factors which potentially contribute to non-union including stainless steel plate material, high construct rigidity scores and purely locking screw constructs. These findings may reflect that overly rigid plating constructs can contribute to non-union. However, they should be taken in the context of heterogeneity amongst included studies, with further research necessary to support these findings.
Collapse
Affiliation(s)
- Michael Tianfeng Wang
- Department of Surgery, Austin Health, Heidelberg, Victoria, Australia; Faculty of Medicine, Nursing and Health Sciences, Monash University, Victoria, Australia.
| | - Vincent V G An
- Department of Surgery, Royal Prince Alfred Hospital, Australia; Faculty of Medicine and Health, Sydney University, New South Wales, Australia.
| | - Brahman Shankar Sivakumar
- Department of Hand Surgery & Microsurgery, Liverpool & Fairfield Hospitals, New South Wales, Australia.
| |
Collapse
|
39
|
Consigliere P, Iliopoulos E, Ads T, Trompeter A. Early versus delayed weight bearing after surgical fixation of distal femur fractures: a non-randomized comparative study. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2019; 29:1789-1794. [PMID: 31267203 DOI: 10.1007/s00590-019-02486-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 06/27/2019] [Indexed: 01/06/2023]
Abstract
Distal femur fractures are rare injuries with a bimodal distribution (high-energy injury in young males and low-energy fragility fractures in old females). Their management can be challenging: open reduction and internal fixation (ORIF) with distal femur locking plates is a commonly performed procedure especially in comminuted fractures with articular involvement. Anxiety regarding the stability of the fixation, especially in osteoporotic bone, leads to post-operative restrictive instructions with limitations regarding the weight-bearing status. Early weight bearing (EWB), however, was shown to enhance bone healing and was not correlated with an increased risk of fracture displacement or implant failure in previous published studies, which reported the results of proximal femur, tibia and ankle fractures surgical treatment. The current study analysed the results of a series of distal femur fractures (51 patients, mean age 64.3 ± 20.7) all treated with ORIF in a level-I major trauma centre, but differently rehabilitated. Group A was, in fact, instructed not to weight bear or to touch weight bear, while group B started to weight bear soon after surgery without specific restrictions. The objective was to compare the outcome and the complication rate in the two groups at 6 and 12 weeks after surgery. The results showed no statistically significant differences in the two groups and no post-operative complications in the EWB group. Six complications were observed in the non-weight-bearing group (four fractures displacement and two implants failure at 12-week follow-up). Distal femur fractures treated with locking plates can be rehabilitated with EWB to allow early return to function. There is no evidence that EWB increases the risk of fracture displacement or implant failure in distal femur fractures treated with distal locking plates. Instead, it is possible that post-operative non-weight-bearing status delays the fracture-healing process increasing the risk of failure of the fixation.
Collapse
Affiliation(s)
- Paolo Consigliere
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK.
| | - Efthymios Iliopoulos
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| | - Tamer Ads
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| | - Alex Trompeter
- St George's University Hospital NHS Foundation Trust, Blackshaw Rd, London, SW17 0QT, UK
| |
Collapse
|
40
|
Inacio JV, Malige A, Schroeder JT, Nwachuku CO, Dailey HL. Mechanical characterization of bone quality in distal femur fractures using pre-operative computed tomography scans. Clin Biomech (Bristol, Avon) 2019; 67:20-26. [PMID: 31059970 DOI: 10.1016/j.clinbiomech.2019.04.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 04/16/2019] [Accepted: 04/23/2019] [Indexed: 02/07/2023]
Abstract
BACKGROUND Mechanical testing of implant constructs designed to treat distal femur fractures has been hampered by a lack of clinical data on the biomechanical properties of the distal femur in patients who sustain these fractures. Therefore, the purpose of this study was to use quantitative computed tomography (qCT) to investigate the mechanical characteristics of fractured distal femurs to inform the selection of synthetic materials for biomechanical testing. METHODS Distal femur fractures treated at a Level I trauma center were retrospectively reviewed and 43 cases with preoperative CT scans were identified for analysis. Scans were segmented and each bone fragment was reconstructed as a 3D model. The Young's modulus of the distal femur was determined from voxel-based radiodensity. FINDINGS Median patient age was 72 years (IQR = 57-81), with 26% males and 74% females. Young's modulus in the distal femur was negatively correlated with patient age (R2 = 0.50, p < 0.001). The distribution of patient-specific modulus values was also compared with the compressive modulus ranges for graded polyurethane foams according to ASTM F1839. Bone quality ranged from Grade 25 in younger individuals to Grade 5 in older individuals. CONCLUSION No single grade of synthetic polyurethane foam can be selected to model all clinically important scenarios for biomechanical testing of distal femur fracture fixation devices. Rather, this data can be used to select an appropriate material for a given clinical scenario. A Grade 25 foam is appropriate for implant longevity, whereas for implant stability, Grades 5-15 are more appropriate.
Collapse
Affiliation(s)
- Jordan V Inacio
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA.
| | - Ajith Malige
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum Street, Bethelehem, PA 18015, USA.
| | - Jake T Schroeder
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum Street, Bethelehem, PA 18015, USA.
| | - Chinenye O Nwachuku
- Department of Orthopaedic Surgery, St. Luke's University Health Network, 801 Ostrum Street, Bethelehem, PA 18015, USA.
| | - Hannah L Dailey
- Department of Mechanical Engineering & Mechanics, Lehigh University, Packard Laboratory, 19 Memorial Drive West, Bethlehem, PA 18015, USA.
| |
Collapse
|