1
|
Dias AH, Andersen KF, Fosbøl MØ, Gormsen LC, Andersen FL, Munk OL. Long Axial Field-of-View PET/CT: New Opportunities for Pediatric Imaging. Semin Nucl Med 2025; 55:76-85. [PMID: 39542815 DOI: 10.1053/j.semnuclmed.2024.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2024] [Revised: 10/10/2024] [Accepted: 10/10/2024] [Indexed: 11/17/2024]
Abstract
The combined use of Positron Emission Tomography (PET) and Computed Tomography (CT) has become increasingly vital for diagnosing and managing oncological and infectious diseases in pediatric patients. The introduction of long axial field-of-view (LAFOV) PET/CT scanners, also known as "Total Body PET/CT," marks a significant advancement in nuclear medicine. This new technology enables faster pediatric imaging with substantially reduced radiation exposure and essentially eliminates the need for sedation, addressing previous critical concerns in pediatric imaging. This review will explore the applications and challenges of LAFOV PET/CT in pediatric imaging, highlight the benefits observed at two Danish hospitals, and evaluate its potential to transform the management of pediatric patients.
Collapse
Affiliation(s)
- André Henrique Dias
- Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Aarhus, Denmark.
| | - Kim Francis Andersen
- Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark
| | - Marie Øbro Fosbøl
- Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark
| | - Lars Christian Gormsen
- Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Flemming Littrup Andersen
- Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Ole Lajord Munk
- Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| |
Collapse
|
2
|
Benitez-Aurioles J, Osorio EMV, Aznar MC, Van Herk M, Pan S, Sitch P, France A, Smith E, Davey A. A neural network to create super-resolution MR from multiple 2D brain scans of pediatric patients. Med Phys 2024. [PMID: 39657055 DOI: 10.1002/mp.17563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 11/02/2024] [Accepted: 11/24/2024] [Indexed: 12/17/2024] Open
Abstract
BACKGROUND High-resolution (HR) 3D MR images provide detailed soft-tissue information that is useful in assessing long-term side-effects after treatment in childhood cancer survivors, such as morphological changes in brain structures. However, these images require long acquisition times, so routinely acquired follow-up images after treatment often consist of 2D low-resolution (LR) images (with thick slices in multiple planes). PURPOSE In this work, we present a super-resolution convolutional neural network, based on previous single-image MRI super-resolution work, that can reconstruct a HR image from 2D LR slices in multiple planes in order to facilitate the extraction of structural biomarkers from routine scans. METHODS A multilevel densely connected super-resolution convolutional neural network (mDCSRN) was adapted to take two perpendicular LR scans (e.g., coronal and axial) as tensors and reconstruct a 3D HR image. A training set of 90 HR T1 pediatric head scans from the Adolescent Brain Cognitive Development (ABCD) study was used, with 2D LR images simulated through a downsampling pipeline that introduces motion artifacts, blurring, and registration errors to make the LR scans more realistic to routinely acquired ones. The outputs of the model were compared against simple interpolation in two steps. First, the quality of the reconstructed HR images was assessed using the peak signal-to-noise ratio and structural similarity index compared to baseline. Second, the precision of structure segmentation (using the autocontouring software Limbus AI) in the reconstructed versus the baseline HR images was assessed using mean distance-to-agreement (mDTA) and 95% Hausdorff distance. Three datasets were used: 10 new ABCD images (dataset 1), 18 images from the Children's Brain Tumor Network (CBTN) study (dataset 2) and 6 "real-world" follow-up images of a pediatric head and neck cancer patient (dataset 3). RESULTS The proposed mDCSRN outperformed simple interpolation in terms of visual quality. Similarly, structure segmentations were closer to baseline images after 3D reconstruction. The mDTA improved to, on average (95% confidence interval), 0.7 (0.4-1.0) and 0.8 (0.7-0.9) mm for datasets 1 and 3 respectively, from the interpolation performance of 6.5 (3.6-9.5) and 1.2 (1.0-1.3) mm. CONCLUSIONS We demonstrate that deep learning methods can successfully reconstruct 3D HR images from 2D LR ones, potentially unlocking datasets for retrospective study and advancing research in the long-term effects of pediatric cancer. Our model outperforms standard interpolation, both in perceptual quality and for autocontouring. Further work is needed to validate it for additional structural analysis tasks.
Collapse
Affiliation(s)
- Jose Benitez-Aurioles
- Division of Informatics, Imaging and Data Sciences, University of Manchester, Manchester, UK
| | - Eliana M Vásquez Osorio
- Radiotherapy-Related Research Group, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Marianne C Aznar
- Radiotherapy-Related Research Group, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | - Marcel Van Herk
- Radiotherapy-Related Research Group, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| | | | - Peter Sitch
- The Christie NHS Foundation Trust, Manchester, UK
| | - Anna France
- The Christie NHS Foundation Trust, Manchester, UK
| | - Ed Smith
- The Christie NHS Foundation Trust, Manchester, UK
| | - Angela Davey
- Radiotherapy-Related Research Group, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
| |
Collapse
|
3
|
Wan S, Wu W, Bu W. Application of intranasal dexmedetomidine in magnetic resonance imaging of preterm infants: The ED50, efficacy and safety analysis. Medicine (Baltimore) 2024; 103:e38040. [PMID: 38701317 PMCID: PMC11062713 DOI: 10.1097/md.0000000000038040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 04/05/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND Infants undergoing magnetic resonance imaging (MRI) often require pharmacological sedation. Dexmedetomidine serves as a novel sedative agent that induces a unique unconsciousness similar to natural sleep, and therefore has currently been used as the first choice for sedation in infants and young children. OBJECTIVE To determine the 50% effective dose (ED50) and 95% confidence interval (95%CI) of intranasal dexmedetomidine for MRI in preterm and term infants, and to observe the incidence of adverse events. To explore whether there were differences in ED50 and 95%CI, heart rate (HR) and blood oxygen saturation (SpO2), the induction time and wake-up time and the incidence of adverse events between the 2 groups, so as to provide guidance for clinical safe medication for the meanwhile. METHODS A total of 68 infants were prospectively recruited for MRI examination under drug sedation (1 week ≤ age ≤ 23 weeks or weight ≤ 5kg). The children were divided into 2 groups according to whether they had preterm birth experience (Preterm group, Atterm group). The Dixon up-and-down method was used to explore ED50. The basic vital signs of the 2 groups were recorded, and the heart rate and SpO2 were recorded every 5 minutes until the infants were discharged from the hospital. The induction time, wake-up time and adverse events were recorded. RESULTS The ED50 (95%CI) of intranasal dexmedetomidine in the Preterm group and the Atterm group were 2.23 (2.03-2.66) μg/kg and 2.64 (2.49-2.83) μg/kg, respectively (P < .05). the wake-up time was longer in Preterm group (98.00min) than in Atterm group (81.00 min) (P < .05), the incidence of bradycardia in Preterm group was 3/33, which was higher than that in Atterm group (1/35). There was no difference in the induction time between the 2 groups (P > .05), and there was no significant difference in other adverse events. CONCLUSIONS Intranasal dexmedetomidine can be safely used for sedation in preterm infants undergoing MRI. Compared with term infants, preterm infants have a lower dose of dexmedetomidine, a higher incidence of bradycardia, and a longer weak-up time.
Collapse
Affiliation(s)
- Shengjun Wan
- Department of Anesthesiology, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Wei Wu
- Department of Anesthesiology, CR & WISCO General Hospital, Affiliated to Wuhan University of Science and Technology, Wuhan, China
| | - Wenhao Bu
- Department of Anesthesiology, Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
4
|
Iwasaka-Neder J, Bedoya MA, Connors J, Warfield S, Bixby SD. Morphometric and clinical comparison of MRI-based synthetic CT to conventional CT of the hip in children. Pediatr Radiol 2024; 54:743-757. [PMID: 38421417 DOI: 10.1007/s00247-024-05888-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Revised: 02/03/2024] [Accepted: 02/15/2024] [Indexed: 03/02/2024]
Abstract
BACKGROUND MRI-based synthetic CT (sCT) generates CT-like images from MRI data. OBJECTIVE To evaluate equivalence, inter- and intraobserver reliability, and image quality of sCT compared to conventional (cCT) for assessing hip morphology and maturity in pediatric patients. MATERIALS AND METHODS We prospectively enrolled patients <21 years old with cCT and 3T MRI of the hips/pelvis. A dual-echo gradient-echo sequence was used to generate sCT via a commercially available post-processing software (BoneMRI v1.5 research version, MRIguidance BV, Utrecht, NL). Two pediatric musculoskeletal radiologists measured seven morphologic hip parameters. 3D surface distances between cCT and sCT were computed. Physeal status was established at seven locations with cCT as reference standard. Images were qualitatively scored on a 5-point Likert scale regarding diagnostic quality, signal-to-noise ratio, clarity of bony margin, corticomedullary differentiation, and presence and severity of artifacts. Quantitative evaluation of Hounsfield units (HU) was performed in bone, muscle, and fat tissue. Inter- and intraobserver reliability were measured by intraclass correlation coefficients. The cCT-to-sCT intermodal agreement was assessed via Bland-Altman analysis. The equivalence between modalities was tested using paired two one-sided tests. The quality parameter scores of each imaging modality were compared via Wilcoxon signed-rank test. For tissue-specific HU measurements, mean absolute error and mean percentage error values were calculated using the cCT as the reference standard. RESULTS Thirty-eight hips in 19 patients were included (16.6 ± 3 years, range 9.9-20.9; male = 5). cCT- and sCT-based morphologic measurements demonstrated good to excellent inter- and intraobserver correlation (0.77 CONCLUSION sCT is equivalent to cCT for the assessment of hip morphology, physeal status, and radiodensity assessment in pediatric patients.
Collapse
Affiliation(s)
- Jade Iwasaka-Neder
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA.
| | - M Alejandra Bedoya
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| | - James Connors
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| | - Simon Warfield
- Computational Radiology Laboratory, Boston Children's Hospital, 401 Park Drive, Boston, MA, 02215, USA
| | - Sarah D Bixby
- Department of Radiology, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA
| |
Collapse
|
5
|
He K, Wan D, Li S, Yuan G, Gao M, Han Y, Li Z, Hu D, Meng X, Niu Y. Non-contrast-enhanced magnetic resonance urography for measuring split kidney function in pediatric patients with hydronephrosis: comparison with renal scintigraphy. Pediatr Nephrol 2024; 39:1447-1457. [PMID: 38041747 DOI: 10.1007/s00467-023-06224-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 11/01/2023] [Accepted: 11/02/2023] [Indexed: 12/03/2023]
Abstract
BACKGROUND Split kidney function (SKF) is critical for treatment decision in pediatric patients with hydronephrosis and is commonly measured using renal scintigraphy (RS). Non-contrast-enhanced magnetic resonance urography (NCE-MRU) is increasingly used in clinical practice. This study aimed to investigate the feasibility of using NCE-MRU as an alternative to estimate SKF in pediatric patients with hydronephrosis, compared to RS. METHODS Seventy-five pediatric patients with hydronephrosis were included in this retrospective study. All patients underwent NCE-MRU and RS within 2 weeks. Kidney parenchyma volume (KPV) and texture analysis parameters were obtained from T2-weighted (T2WI) in NCE-MRU. The calculated split KPV (SKPV) percent and texture analysis parameters percent of left kidney were compared with the RS-determined SKF. RESULTS SKPV showed a significant positive correlation with SKF (r = 0.88, p < 0.001), while inhomogeneity was negatively correlated with SKF (r = - 0.68, p < 0.001). The uncorrected and corrected prediction models of SKF were established using simple and multiple linear regression. Bland-Altman plots demonstrated good agreement of both predictive models. The residual sum of squares of the corrected prediction model was lower than that of the uncorrected model (0.283 vs. 0.314) but not statistically significant (p = 0.662). Subgroup analysis based on different MR machines showed correlation coefficients of 0.85, 0.95, and 0.94 between SKF and SKPV for three different scanners, respectively (p < 0.05 for all). CONCLUSIONS NCE-MRU can be used as an alternative method for estimating SKF in pediatric patients with hydronephrosis when comparing with RS. Specifically, SKPV proves to be a simple and universally applicable indicator for predicting SKF.
Collapse
Affiliation(s)
- Kangwen He
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Dongyi Wan
- Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Shichao Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Guanjie Yuan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Mengmeng Gao
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Yunfeng Han
- Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Zhen Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Daoyu Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China
| | - Xiaoyan Meng
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
| | - Yonghua Niu
- Department of Pediatric Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
| |
Collapse
|
6
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
7
|
Rastogi A, Brugnara G, Foltyn-Dumitru M, Mahmutoglu MA, Preetha CJ, Kobler E, Pflüger I, Schell M, Deike-Hofmann K, Kessler T, van den Bent MJ, Idbaih A, Platten M, Brandes AA, Nabors B, Stupp R, Bernhardt D, Debus J, Abdollahi A, Gorlia T, Tonn JC, Weller M, Maier-Hein KH, Radbruch A, Wick W, Bendszus M, Meredig H, Kurz FT, Vollmuth P. Deep-learning-based reconstruction of undersampled MRI to reduce scan times: a multicentre, retrospective, cohort study. Lancet Oncol 2024; 25:400-410. [PMID: 38423052 DOI: 10.1016/s1470-2045(23)00641-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 11/20/2023] [Accepted: 12/07/2023] [Indexed: 03/02/2024]
Abstract
BACKGROUND The extended acquisition times required for MRI limit its availability in resource-constrained settings. Consequently, accelerating MRI by undersampling k-space data, which is necessary to reconstruct an image, has been a long-standing but important challenge. We aimed to develop a deep convolutional neural network (dCNN) optimisation method for MRI reconstruction and to reduce scan times and evaluate its effect on image quality and accuracy of oncological imaging biomarkers. METHODS In this multicentre, retrospective, cohort study, MRI data from patients with glioblastoma treated at Heidelberg University Hospital (775 patients and 775 examinations) and from the phase 2 CORE trial (260 patients, 1083 examinations, and 58 institutions) and the phase 3 CENTRIC trial (505 patients, 3147 examinations, and 139 institutions) were used to develop, train, and test dCNN for reconstructing MRI from highly undersampled single-coil k-space data with various acceleration rates (R=2, 4, 6, 8, 10, and 15). Independent testing was performed with MRIs from the phase 2/3 EORTC-26101 trial (528 patients with glioblastoma, 1974 examinations, and 32 institutions). The similarity between undersampled dCNN-reconstructed and original MRIs was quantified with various image quality metrics, including structural similarity index measure (SSIM) and the accuracy of undersampled dCNN-reconstructed MRI on downstream radiological assessment of imaging biomarkers in oncology (automated artificial intelligence-based quantification of tumour burden and treatment response) was performed in the EORTC-26101 test dataset. The public NYU Langone Health fastMRI brain test dataset (558 patients and 558 examinations) was used to validate the generalisability and robustness of the dCNN for reconstructing MRIs from available multi-coil (parallel imaging) k-space data. FINDINGS In the EORTC-26101 test dataset, the median SSIM of undersampled dCNN-reconstructed MRI ranged from 0·88 to 0·99 across different acceleration rates, with 0·92 (95% CI 0·92-0·93) for 10-times acceleration (R=10). The 10-times undersampled dCNN-reconstructed MRI yielded excellent agreement with original MRI when assessing volumes of contrast-enhancing tumour (median DICE for spatial agreement of 0·89 [95% CI 0·88 to 0·89]; median volume difference of 0·01 cm3 [95% CI 0·00 to 0·03] equalling 0·21%; p=0·0036 for equivalence) or non-enhancing tumour or oedema (median DICE of 0·94 [95% CI 0·94 to 0·95]; median volume difference of -0·79 cm3 [95% CI -0·87 to -0·72] equalling -1·77%; p=0·023 for equivalence) in the EORTC-26101 test dataset. Automated volumetric tumour response assessment in the EORTC-26101 test dataset yielded an identical median time to progression of 4·27 months (95% CI 4·14 to 4·57) when using 10-times-undersampled dCNN-reconstructed or original MRI (log-rank p=0·80) and agreement in the time to progression in 374 (95·2%) of 393 patients with data. The dCNN generalised well to the fastMRI brain dataset, with significant improvements in the median SSIM when using multi-coil compared with single-coil k-space data (p<0·0001). INTERPRETATION Deep-learning-based reconstruction of undersampled MRI allows for a substantial reduction of scan times, with a 10-times acceleration demonstrating excellent image quality while preserving the accuracy of derived imaging biomarkers for the assessment of oncological treatment response. Our developments are available as open source software and hold considerable promise for increasing the accessibility to MRI, pending further prospective validation. FUNDING Deutsche Forschungsgemeinschaft (German Research Foundation) and an Else Kröner Clinician Scientist Endowed Professorship by the Else Kröner Fresenius Foundation.
Collapse
Affiliation(s)
- Aditya Rastogi
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Gianluca Brugnara
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Martha Foltyn-Dumitru
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Mustafa Ahmed Mahmutoglu
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Chandrakanth J Preetha
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Erich Kobler
- Department of Neuroradiology, University Medical Center Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
| | - Irada Pflüger
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Marianne Schell
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Katerina Deike-Hofmann
- Department of Neuroradiology, University Medical Center Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany; German Center for Neurodegenerative Diseases, Bonn, Germany
| | - Tobias Kessler
- Neurology Clinic, Heidelberg University Hospital, Heidelberg, Germany; Clinical Cooperation Unit Neurooncology, German Cancer Consortium within German Cancer Research Center, Heidelberg, Germany
| | | | - Ahmed Idbaih
- Assistance Publique-Hôpitaux de Paris, Service de Neurologie 1, Hôpital Pitié-Salpêtrière, Sorbonne Université, Paris, France
| | - Michael Platten
- Department of Neurology, Medical Faculty Mannheim, Mannheim Center for Translational Neuroscience, University of Heidelberg, Mannheim, Germany; Clinical Cooperation Unit Neuroimmunology and Brain Tumor Immunology, German Cancer Consortium within German Cancer Research Center, Heidelberg, Germany
| | - Alba A Brandes
- Department of Medical Oncology, Azienda UnitàSanitaria Locale of Bologna, Bologna, Italy
| | - Burt Nabors
- Department of Neurology, Division of Neuro-Oncology, University of Alabama at Birmingham, Birmingham, AL, USA; O'Neal Comprehensive Cancer Center, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Roger Stupp
- Lou and Jean Malnati Brain Tumor Institute, Robert H Lurie Comprehensive Cancer Center, Northwestern Medicine and Northwestern University, Chicago, USA; Department of Neurological Surgery, Northwestern Medicine and Northwestern University, Chicago, USA; Department of Neurology, Northwestern Medicine and Northwestern University, Chicago, USA
| | - Denise Bernhardt
- Department of Radiation Oncology, School of Medicine and Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Institute of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Ion-Beam Therapy Center, Heidelberg University Hospital, Heidelberg, Germany
| | - Amir Abdollahi
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Institute of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany; Heidelberg Ion-Beam Therapy Center, Heidelberg University Hospital, Heidelberg, Germany
| | - Thierry Gorlia
- European Organization for Research and Treatment of Cancer, Brussels, Belgium
| | - Jörg-Christian Tonn
- Department of Neurosurgery, Ludwig-Maximilians-University, Munich, Germany; German Cancer Consortium within German Center Research Center, partner site Munich, Germany
| | - Michael Weller
- Department of Neurology, University Hospital and University of Zurich, Zurich, Switzerland
| | - Klaus H Maier-Hein
- Medical Image Computing, German Cancer Research Center, Heidelberg, Germany; Pattern Analysis and Learning Group, Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Alexander Radbruch
- Department of Neuroradiology, University Medical Center Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
| | - Wolfgang Wick
- Neurology Clinic, Heidelberg University Hospital, Heidelberg, Germany; Clinical Cooperation Unit Neurooncology, German Cancer Consortium within German Cancer Research Center, Heidelberg, Germany
| | - Martin Bendszus
- Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Hagen Meredig
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Felix T Kurz
- Division of Diagnostic and Interventional Neuroradiology, Geneva University Hospitals, Geneva, Switzerland; Department of Radiology, German Cancer Research Center, Heidelberg, Germany
| | - Philipp Vollmuth
- Division for Computational Neuroimaging, Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany; Department of Neuroradiology, University Medical Center Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany; Medical Image Computing, German Cancer Research Center, Heidelberg, Germany.
| |
Collapse
|
8
|
Roya M, Mostafapour S, Mohr P, Providência L, Li Z, van Snick JH, Brouwers AH, Noordzij W, Willemsen ATM, Dierckx RAJO, Lammertsma AA, Glaudemans AWJM, Tsoumpas C, Slart RHJA, van Sluis J. Current and Future Use of Long Axial Field-of-View Positron Emission Tomography/Computed Tomography Scanners in Clinical Oncology. Cancers (Basel) 2023; 15:5173. [PMID: 37958347 PMCID: PMC10648837 DOI: 10.3390/cancers15215173] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2023] [Revised: 10/23/2023] [Accepted: 10/24/2023] [Indexed: 11/15/2023] Open
Abstract
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.
Collapse
Affiliation(s)
- Mostafa Roya
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Samaneh Mostafapour
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Philipp Mohr
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Laura Providência
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Zekai Li
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Johannes H. van Snick
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Adrienne H. Brouwers
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Walter Noordzij
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Antoon T. M. Willemsen
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Rudi A. J. O. Dierckx
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Adriaan A. Lammertsma
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Andor W. J. M. Glaudemans
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Charalampos Tsoumpas
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| | - Riemer H. J. A. Slart
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
- Department of Biomedical Photonic Imaging, Faculty of Science and Technology, University of Twente, 7522 NB Enchede, The Netherlands
| | - Joyce van Sluis
- Department of Nuclear Medicine and Molecular Imaging, Medical Imaging Center, University Medical Center Groningen, University of Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands; (S.M.); (P.M.); (L.P.); (Z.L.); (J.H.v.S.); (A.H.B.); (W.N.); (A.T.M.W.); (R.A.J.O.D.); (A.A.L.); (A.W.J.M.G.); (C.T.); (J.v.S.)
| |
Collapse
|
9
|
Wary P, Hossu G, Ambarki K, Nickel D, Arberet S, Oster J, Orry X, Laurent V. Deep learning HASTE sequence compared with T2-weighted BLADE sequence for liver MRI at 3 Tesla: a qualitative and quantitative prospective study. Eur Radiol 2023; 33:6817-6827. [PMID: 37188883 DOI: 10.1007/s00330-023-09693-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2022] [Revised: 02/26/2023] [Accepted: 03/11/2023] [Indexed: 05/17/2023]
Abstract
OBJECTIVES To qualitatively and quantitatively compare a single breath-hold fast half-Fourier single-shot turbo spin echo sequence with deep learning reconstruction (DL HASTE) with T2-weighted BLADE sequence for liver MRI at 3 T. METHODS From December 2020 to January 2021, patients with liver MRI were prospectively included. For qualitative analysis, sequence quality, presence of artifacts, conspicuity, and presumed nature of the smallest lesion were assessed using the chi-squared and McNemar tests. For quantitative analysis, number of liver lesions, size of the smallest lesion, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in both sequences were assessed using the paired Wilcoxon signed-rank test. Intraclass correlation coefficients (ICCs) and kappa coefficients were used to assess agreement between the two readers. RESULTS One hundred and twelve patients were evaluated. Overall image quality (p = .006), artifacts (p < .001), and conspicuity of the smallest lesion (p = .001) were significantly better for the DL HASTE sequence than for the T2-weighted BLADE sequence. Significantly more liver lesions were detected with the DL HASTE sequence (356 lesions) than with the T2-weighted BLADE sequence (320 lesions; p < .001). CNR was significantly higher for the DL HASTE sequence (p < .001). SNR was higher for the T2-weighted BLADE sequence (p < .001). Interreader agreement was moderate to excellent depending on the sequence. Of the 41 supernumerary lesions visible only on the DL HASTE sequence, 38 (93%) were true-positives. CONCLUSION The DL HASTE sequence can be used to improve image quality and contrast and reduces artifacts, allowing the detection of more liver lesions than with the T2-weighted BLADE sequence. CLINICAL RELEVANCE STATEMENT The DL HASTE sequence is superior to the T2-weighted BLADE sequence for the detection of focal liver lesions and can be used in daily practice as a standard sequence. KEY POINTS • The half-Fourier acquisition single-shot turbo spin echo sequence with deep learning reconstruction (DL HASTE sequence) has better overall image quality, reduced artifacts (particularly motion artifacts), and improved contrast, allowing the detection of more liver lesions than with the T2-weighted BLADE sequence. • The acquisition time of the DL HASTE sequence is at least eight times faster (21 s) than that of the T2-weighted BLADE sequence (3-5 min). • The DL HASTE sequence could replace the conventional T2-weighted BLADE sequence to meet the growing indication for hepatic MRI in clinical practice, given its diagnostic and time-saving performance.
Collapse
Affiliation(s)
- Pierre Wary
- Department of Adult Radiology, CHRU de Nancy, 5 Rue du Morvan, 54500, Vandoeuvre-lès-Nancy, France.
| | - Gabriela Hossu
- Clinical Investigation Center Technological Innovation of Nancy, Inserm, CHRU de Nancy, Vandoeuvre-lès-Nancy, France
- Adaptive Diagnostic and Interventional Imaging, Inserm, CHRU de Nancy, Vandoeuvre-lès-Nancy, France
| | - Khalid Ambarki
- Siemens Healthcare, Siemens Healthcare SAS, Saint Denis, France
| | - Dominik Nickel
- Siemens Healthcare GmbH, MR Application Predevelopment, Erlangen, Germany
| | - Simon Arberet
- Siemens Healthineers, Digital Technology & Innovation, Princeton, NJ, USA
| | - Julien Oster
- Clinical Investigation Center Technological Innovation of Nancy, Inserm, CHRU de Nancy, Vandoeuvre-lès-Nancy, France
- Adaptive Diagnostic and Interventional Imaging, Inserm, CHRU de Nancy, Vandoeuvre-lès-Nancy, France
| | - Xavier Orry
- Department of Adult Radiology, CHRU de Nancy, 5 Rue du Morvan, 54500, Vandoeuvre-lès-Nancy, France
| | - Valérie Laurent
- Department of Adult Radiology, CHRU de Nancy, 5 Rue du Morvan, 54500, Vandoeuvre-lès-Nancy, France
- Adaptive Diagnostic and Interventional Imaging, Inserm, CHRU de Nancy, Vandoeuvre-lès-Nancy, France
| |
Collapse
|
10
|
Lacharie M, Villa A, Milidonis X, Hasaneen H, Chiribiri A, Benedetti G. Role of pulmonary perfusion magnetic resonance imaging for the diagnosis of pulmonary hypertension: A review. World J Radiol 2023; 15:256-273. [PMID: 37823020 PMCID: PMC10563854 DOI: 10.4329/wjr.v15.i9.256] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 09/16/2023] [Accepted: 09/22/2023] [Indexed: 09/27/2023] Open
Abstract
Among five types of pulmonary hypertension, chronic thromboembolic pulmonary hypertension (CTEPH) is the only curable form, but prompt and accurate diagnosis can be challenging. Computed tomography and nuclear medicine-based techniques are standard imaging modalities to non-invasively diagnose CTEPH, however these are limited by radiation exposure, subjective qualitative bias, and lack of cardiac functional assessment. This review aims to assess the methodology, diagnostic accuracy of pulmonary perfusion imaging in the current literature and discuss its advantages, limitations and future research scope.
Collapse
Affiliation(s)
- Miriam Lacharie
- Oxford Centre of Magnetic Resonance Imaging, University of Oxford, Oxford OX3 9DU, United Kingdom
| | - Adriana Villa
- Department of Diagnostic and Interventional Radiology, German Oncology Centre, Limassol 4108, Cyprus
| | - Xenios Milidonis
- Deep Camera MRG, CYENS Centre of Excellence, Nicosia, Cyprus, Nicosia 1016, Cyprus
| | - Hadeer Hasaneen
- School of Biomedical Engineering & Imaging Sciences, King's College London, London WC2R 2LS, United Kingdom
| | - Amedeo Chiribiri
- School of Biomedical Engineering and Imaging Sciences, Kings Coll London, Div Imaging Sci, St Thomas Hospital, London WC2R 2LS, United Kingdom
| | - Giulia Benedetti
- Department of Cardiovascular Imaging and Biomedical Engineering, King’s College London, London WC2R 2LS, United Kingdom
| |
Collapse
|
11
|
Meister RL, Groth M, Zhang S, Buhk JH, Herrmann J. Evaluation of Artifact Appearance and Burden in Pediatric Brain Tumor MR Imaging with Compressed Sensing in Comparison to Conventional Parallel Imaging Acceleration. J Clin Med 2023; 12:5732. [PMID: 37685799 PMCID: PMC10489124 DOI: 10.3390/jcm12175732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/25/2023] [Accepted: 08/30/2023] [Indexed: 09/10/2023] Open
Abstract
Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts.
Collapse
Affiliation(s)
- Rieke Lisa Meister
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
- Department of Medical Imaging, Southland Hospital, Invercargill 9812, New Zealand
| | - Michael Groth
- Department of Radiology, St. Marienhospital Vechta, 49377 Vechta, Germany
| | - Shuo Zhang
- Philips Healthcare, 22335 Hamburg, Germany;
| | - Jan-Hendrik Buhk
- Department of Neuroradiology, Asklepios Kliniken St. Georg und Wandsbek, 22043 Hamburg, Germany
| | - Jochen Herrmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany
| |
Collapse
|
12
|
Li T, Wang J, Yang Y, Glide-Hurst CK, Wen N, Cai J. Multi-parametric MRI for radiotherapy simulation. Med Phys 2023; 50:5273-5293. [PMID: 36710376 PMCID: PMC10382603 DOI: 10.1002/mp.16256] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 09/10/2022] [Accepted: 12/06/2022] [Indexed: 01/31/2023] Open
Abstract
Magnetic resonance imaging (MRI) has become an important imaging modality in the field of radiotherapy (RT) in the past decade, especially with the development of various novel MRI and image-guidance techniques. In this review article, we will describe recent developments and discuss the applications of multi-parametric MRI (mpMRI) in RT simulation. In this review, mpMRI refers to a general and loose definition which includes various multi-contrast MRI techniques. Specifically, we will focus on the implementation, challenges, and future directions of mpMRI techniques for RT simulation.
Collapse
Affiliation(s)
- Tian Li
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| | - Jihong Wang
- Department of Radiation Physics, Division of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas, USA
| | - Yingli Yang
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
| | - Carri K Glide-Hurst
- Department of Radiation Oncology, University of Wisconsin, Madison, Wisconsin, USA
| | - Ning Wen
- Department of Radiology, Ruijin Hospital, Shanghai Jiaotong Univeristy School of Medicine, Shanghai, China
- SJTU-Ruijing-UIH Institute for Medical Imaging Technology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China
- The Global Institute of Future Technology, Shanghai Jiaotong University, Shanghai, China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China
| |
Collapse
|
13
|
Grzywińska M, Świętoń D, Sabisz A, Piskunowicz M. Functional Magnetic Resonance Urography in Children-Tips and Pitfalls. Diagnostics (Basel) 2023; 13:diagnostics13101786. [PMID: 37238270 DOI: 10.3390/diagnostics13101786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 05/13/2023] [Accepted: 05/15/2023] [Indexed: 05/28/2023] Open
Abstract
MR urography can be an alternative to other imaging methods of the urinary tract in children. However, this examination may present technical problems influencing further results. Special attention must be paid to the parameters of dynamic sequences to obtain valuable data for further functional analysis. The analysis of methodology for renal function assessment using 3T magnetic resonance in children. A retrospective analysis of MR urography studies was performed in a group of 91 patients. Particular attention was paid to the acquisition parameters of the 3D-Thrive dynamic with contrast medium administration as a basic urography sequence. The authors have evaluated images qualitatively and compared contrast-to-noise ratio (CNR), curves smoothness, and quality of baseline (evaluation signal noise ratio) in every dynamic in each patient in every protocol used in our institution. Quality analysis of the image (ICC = 0.877, p < 0.001) was improved so that we have a statistically significant difference in image quality between protocols (χ2(3) = 20.134, p < 0.001). The results obtained for SNR in the medulla and cortex show that there was a statistically significant difference in SNR in the cortex (χ2(3) = 9.060, p = 0.029). Therefore, the obtained results show that with the newer protocol, we obtain lower values of standard deviation for TTP in the aorta (in ChopfMRU: first protocol SD = 14.560 vs. fourth protocol SD = 5.599; in IntelliSpace Portal: first protocol SD = 15.241 vs. fourth protocol SD = 5.506). Magnetic resonance urography is a promising technique with a few challenges that arise and need to be overcome. New technical opportunities should be introduced for everyday practice to improve MRU results.
Collapse
Affiliation(s)
- Małgorzata Grzywińska
- Applied Cognitive Neuroscience Lab., Department of Neurophysiology, Neuropsychology and Neuroinformatics, Medical University of Gdansk, 80-210 Gdansk, Poland
| | - Dominik Świętoń
- 2nd Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland
| | - Agnieszka Sabisz
- 2nd Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland
| | - Maciej Piskunowicz
- 1st Department of Radiology, Medical University of Gdansk, 80-210 Gdansk, Poland
| |
Collapse
|
14
|
Schulze-Zachau V, Winkel DJ, Kaul F, Demerath T, Potthast S, Heye TJ, Boll DT. Estimation of differential renal function on routine abdominal imaging employing compressed-sensed contrast-enhanced MR: a feasibility study referenced against dynamic renal scintigraphy in patients with deteriorating renal retention parameters. Abdom Radiol (NY) 2023; 48:1329-1339. [PMID: 36732406 PMCID: PMC10115688 DOI: 10.1007/s00261-023-03823-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 01/17/2023] [Accepted: 01/17/2023] [Indexed: 02/04/2023]
Abstract
PURPOSE To assess whether high temporal/spatial resolution GRASP MRI acquired during routine clinical imaging can identify several degrees of renal function impairment referenced against renal dynamic scintigraphy. METHODS This retrospective study consists of method development and method verification parts. During method development, patients subject to renal imaging using gadoterate meglumine and GRASP post-contrast MRI technique (TR/TE 3.3/1.6 ms; FoV320 × 320 mm; FA12°; Voxel1.1 × 1.1x2.5 mm) were matched into four equally-sized renal function groups (no-mild-moderate-severe impairment) according to their laboratory-determined estimated glomerular filtration rates (eGFR); 60|120 patients|kidneys were included. Regions-of-interest (ROIs) were placed on cortices, medullary pyramids and collecting systems of bilateral kidneys. Cortical perfusion, tubular concentration and collecting system excretion were determined as TimeCortex=Pyramid(sec), SlopeTubuli (sec-1), and TimeCollecting System (sec), respectively, and were measured by a combination of extraction of time intensity curves and respective quantitative parameters. For method verification, patients subject to GRASP MRI and renal dynamic scintigraphy (99mTc-MAG3, 100 MBq/patient) were matched into three renal function groups (no-mild/moderate-severe impairment). Split renal function parameters post 1.5-2.5 min as well as MAG3 TER were correlated with time intensity parameters retrieved using GRASP technique; 15|30 patients|kidneys were included. RESULTS Method development showed differing values for TimeCortex=Pyramid(71|75|93|122 s), SlopeTubuli(2.6|2.1|1.3|0.5 s-1) and TimeCollecting System(90|111|129|139 s) for the four renal function groups with partial significant tendencies (several p-values < 0.001). In method verification, 29/30 kidneys (96.7%) were assigned to the correct renal function group. CONCLUSION High temporal and spatial resolution GRASP MR imaging allows to identify several degrees of renal function impairment using routine clinical imaging with a high degree of accuracy.
Collapse
Affiliation(s)
| | - David J Winkel
- Department of Radiology, University Hospital of Basel, 4031, Basel, Switzerland.
| | - Felix Kaul
- Department of Nuclear Medicine, University Hospital of Basel, Basel, Switzerland
| | - Theo Demerath
- Neuroradiology Clinic, University Medical Center Freiburg, Freiburg, Germany
| | - Silke Potthast
- Department of Radiology, Spital Limmattal, Schlieren, Switzerland
| | - Tobias J Heye
- Department of Radiology, University Hospital of Basel, 4031, Basel, Switzerland
| | - Daniel T Boll
- Department of Radiology, University Hospital of Basel, 4031, Basel, Switzerland
| |
Collapse
|
15
|
Koch V, Merklein D, Zangos S, Eichler K, Gruenewald LD, Mahmoudi S, Booz C, Yel I, D'Angelo T, Martin SS, Bernatz S, Hammerstingl RM, Albrecht MH, Scholtz JE, Kaltenbach B, Vogl TJ, Langenbach M, Gruber-Rouh T. Free-breathing accelerated whole-body MRI using an automated workflow: Comparison with conventional breath-hold sequences. NMR IN BIOMEDICINE 2023; 36:e4828. [PMID: 36082477 DOI: 10.1002/nbm.4828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/15/2022] [Accepted: 09/06/2022] [Indexed: 06/15/2023]
Abstract
Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (ϰ = 0.96 [95% CI 0.88-1.00]) and conventional scans (ϰ = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.
Collapse
Affiliation(s)
- Vitali Koch
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Domenica Merklein
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Stephan Zangos
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Katrin Eichler
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Leon D Gruenewald
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Scherwin Mahmoudi
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Christian Booz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Ibrahim Yel
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Tommaso D'Angelo
- Department of Biomedical Sciences and Morphological and Functional Imaging, University Hospital Messina, Messina, Italy
| | - Simon S Martin
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Simon Bernatz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Renate M Hammerstingl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Moritz H Albrecht
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Jan-Erik Scholtz
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Benjamin Kaltenbach
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Thomas J Vogl
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Marcel Langenbach
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Tatjana Gruber-Rouh
- Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt am Main, Germany
| |
Collapse
|
16
|
Gallo-Bernal S, Bedoya MA, Gee MS, Jaimes C. Pediatric magnetic resonance imaging: faster is better. Pediatr Radiol 2022:10.1007/s00247-022-05529-x. [PMID: 36261512 DOI: 10.1007/s00247-022-05529-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 08/29/2022] [Accepted: 10/03/2022] [Indexed: 10/24/2022]
Abstract
Magnetic resonance imaging (MRI) has emerged as the preferred imaging modality for evaluating a wide range of pediatric medical conditions. Nevertheless, the long acquisition times associated with this technique can limit its widespread use in young children, resulting in motion-degraded or non-diagnostic studies. As a result, sedation or general anesthesia is often necessary to obtain diagnostic images, which has implications for the safety profile of MRI, the cost of the exam and the radiology department's clinical workflow. Over the last decade, several techniques have been developed to increase the speed of MRI, including parallel imaging, single-shot acquisition, controlled aliasing techniques, compressed sensing and artificial-intelligence-based reconstructions. These are advantageous because shorter examinations decrease the need for sedation and the severity of motion artifacts, increase scanner throughput, and improve system efficiency. In this review we discuss a framework for image acceleration in children that includes the synergistic use of state-of-the-art MRI hardware and optimized pulse sequences. The discussion is framed within the context of pediatric radiology and incorporates the authors' experience in deploying these techniques in routine clinical practice.
Collapse
Affiliation(s)
- Sebastian Gallo-Bernal
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - M Alejandra Bedoya
- Department of Radiology, Harvard Medical School, Boston, MA, USA.,Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA
| | - Michael S Gee
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.,Department of Radiology, Harvard Medical School, Boston, MA, USA
| | - Camilo Jaimes
- Department of Radiology, Harvard Medical School, Boston, MA, USA. .,Department of Radiology, Boston Children's Hospital, 300 Longwood Ave., 2nd floor, Main Building, Boston, MA, 02115, USA.
| |
Collapse
|
17
|
State-of-the-art magnetic resonance imaging sequences for pediatric body imaging. Pediatr Radiol 2022:10.1007/s00247-022-05528-y. [PMID: 36255456 DOI: 10.1007/s00247-022-05528-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2022] [Revised: 08/17/2022] [Accepted: 10/03/2022] [Indexed: 10/24/2022]
Abstract
Longer examination time, need for anesthesia in smaller children and the inability of most children to hold their breath are major limitations of MRI in pediatric body imaging. Fortunately, with technical advances, many new and upcoming MRI sequences are overcoming these limitations. Advances in data acquisition and k-space sampling methods have enabled sequences with improved temporal and spatial resolution, and minimal artifacts. Sequences to minimize movement artifacts mainly utilize radial k-space filling, and examples include the stack-of-stars method for T1-weighted imaging and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER)/BLADE method for T2-weighted imaging. Similarly, the sequences with improved temporal resolution and the ability to obtain multiple phases in a single breath-hold in dynamic imaging mainly use some form of partial k-space filling method. New sequences use a variable combination of data sampling methods like compressed sensing, golden-angle radial k-space filling, parallel imaging and partial k-space filling to achieve free-breathing, faster sequences that could be useful for pediatric abdominal and thoracic imaging. Simultaneous multi-slice method has improved diffusion-weighted imaging (DWI) with reduction in scan time and artifacts. In this review, we provide an overview of data sampling methods like parallel imaging, compressed sensing, radial k-space sampling, partial k-space sampling and simultaneous multi-slice. This is followed by newer available and upcoming sequences for T1-, T2- and DWI based on these other advances. We also discuss the Dixon method and newer approaches to reducing metal artifacts.
Collapse
|
18
|
Blind image quality assessment of magnetic resonance images with statistics of local intensity extrema. Inf Sci (N Y) 2022. [DOI: 10.1016/j.ins.2022.05.061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
19
|
Liang X, Bi Z, Yang C, Sheng R, Xia X, Zhang Z, Dai Y, Zeng M. Free-Breathing Liver Magnetic Resonance Imaging With Respiratory Frequency-Modulated Continuous-Wave Radar-Trigger Technique: A Preliminary Study. Front Oncol 2022; 12:918173. [PMID: 35719930 PMCID: PMC9200370 DOI: 10.3389/fonc.2022.918173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Accepted: 05/03/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose The aim of this study is to evaluate the performance of free-breathing liver MRI with a novel respiratory frequency-modulated continuous-wave radar-trigger (FT) technique on T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) for both healthy volunteers and patients in comparison to navigator-trigger (NT) and belt-trigger (BT) techniques. Methods In this prospective study, 17 healthy volunteers and 23 patients with known or suspected liver diseases were enrolled. Six sequences (T2WI and DWI with FT, NT, and BT techniques) were performed in each subject. Quantitative evaluation and qualitative assessment were analyzed by two radiologists. Overall image quality, blurring, motion artifacts, and liver edge delineations were rated on a 4-point Likert scale. The liver and lesion signal-to-noise ratio (SNR), the lesion-to-liver contrast-to-noise ratio (CNR), as well as the apparent diffusion coefficient (ADC) value were quantitatively calculated. Results For volunteers, there were no significant differences in the image quality Likert scores and quantitative parameters on T2WI and DWI with three respiratory-trigger techniques. For patients, NT was superior to other techniques for image quality on T2WI; conversely, little difference was found on DWI in qualitative assessment. The mean SNR of the liver on T2WI and DWI with BT, NT, and FT techniques was similar in patients, which is in line with volunteers. FT performed better in terms of higher SNR (705.13 ± 434.80) and higher CNR (504.41 ± 400.69) on DWI at b50 compared with BT (SNR: 651.83 ± 401.16; CNR:429.24 ± 404.11) and NT (SNR: 639.41 ± 407.98; CNR: 420.64 ± 416.61) (p < 0.05). The mean ADC values of the liver and lesion with different techniques in both volunteers and patients showed non-significant difference. Conclusion For volunteers, the performance of T2WI as well as DWI with three respiratory-trigger techniques was similarly good. As for patients, FT-DWI is superior to BT and NT techniques in terms of higher lesion SNR and CNR at b50.
Collapse
Affiliation(s)
- Xinyue Liang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zhenghong Bi
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Chun Yang
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Ruofan Sheng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| | - Xinyuan Xia
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Zheng Zhang
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, China
| | - Mengsu Zeng
- Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China.,Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
20
|
Neonatal body magnetic resonance imaging: preparation, performance and optimization. Pediatr Radiol 2022; 52:676-684. [PMID: 34156505 DOI: 10.1007/s00247-021-05118-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 04/27/2021] [Accepted: 06/01/2021] [Indexed: 10/21/2022]
Abstract
Performing and optimizing MRI of the chest, abdomen and pelvis in neonates and young infants can be challenging. This is a result of several factors, including patient size, desire to avoid or minimize sedation/general anesthesia, and the relative rarity of these examinations. However, with proper preparation and protocol optimization, high-quality diagnostic images can be acquired that can aid in diagnosis and patient management. In addition, numerous special considerations arise when performing body MRI in neonates compared to older pediatric patients. This review article provides an update on the performance and optimization of MRI of the body in neonates and infants. Furthermore, the authors present common indications for neonatal body MRI and discuss the use of intravenous gadolinium-based contrast agents in this vulnerable patient population.
Collapse
|
21
|
Zhu L, He Q, Huang Y, Zhang Z, Zeng J, Lu L, Kong W, Zhou F. DualMMP-GAN: Dual-scale multi-modality perceptual generative adversarial network for medical image segmentation. Comput Biol Med 2022; 144:105387. [PMID: 35305502 DOI: 10.1016/j.compbiomed.2022.105387] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Revised: 03/04/2022] [Accepted: 03/04/2022] [Indexed: 01/22/2023]
Abstract
Multi-modality magnetic resonance imaging (MRI) can reveal distinct patterns of tissue in the human body and is crucial to clinical diagnosis. But it still remains a challenge to obtain diverse and plausible multi-modality MR images due to expense, noise, and artifacts. For the same lesion, different modalities of MRI have big differences in context information, coarse location, and fine structure. In order to achieve better generation and segmentation performance, a dual-scale multi-modality perceptual generative adversarial network (DualMMP-GAN) is proposed based on cycle-consistent generative adversarial networks (CycleGAN). Dilated residual blocks are introduced to increase the receptive field, preserving structure and context information of images. A dual-scale discriminator is constructed. The generator is optimized by discriminating patches to represent lesions with different sizes. The perceptual consistency loss is introduced to learn the mapping between the generated and target modality at different semantic levels. Moreover, generative multi-modality segmentation (GMMS) combining given modalities with generated modalities is proposed for brain tumor segmentation. Experimental results show that the DualMMP-GAN outperforms the CycleGAN and some state-of-the-art methods in terms of PSNR, SSMI, and RMSE in most tasks. In addition, dice, sensitivity, specificity, and Hausdorff95 obtained from segmentation by GMMS are all higher than those from a single modality. The objective index obtained by the proposed methods are close to upper bounds obtained from real multiple modalities, indicating that GMMS can achieve similar effects as multi-modality. Overall, the proposed methods can serve as an effective method in clinical brain tumor diagnosis with promising application potential.
Collapse
Affiliation(s)
- Li Zhu
- School of Information Engineering, Nanchang University, Nanchang, 330031, China.
| | - Qiong He
- School of Information Engineering, Nanchang University, Nanchang, 330031, China.
| | - Yue Huang
- School of Informatics, Xiamen University, Xiamen, 361005, China.
| | - Zihe Zhang
- School of Information Engineering, Nanchang University, Nanchang, 330031, China.
| | - Jiaming Zeng
- School of Information Engineering, Nanchang University, Nanchang, 330031, China.
| | - Ling Lu
- School of Information Engineering, Nanchang University, Nanchang, 330031, China.
| | - Weiming Kong
- Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army, No.908, Nanchang, 330002, China.
| | - Fuqing Zhou
- Department of Radiology, The First Affiliated Hospital, Nanchang University, Nanchang, 330006, China.
| |
Collapse
|
22
|
Bardo DME, Rubert N. Radial sequences and compressed sensing in pediatric body magnetic resonance imaging. Pediatr Radiol 2022; 52:382-390. [PMID: 34009408 DOI: 10.1007/s00247-021-05097-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 03/11/2021] [Accepted: 04/28/2021] [Indexed: 12/28/2022]
Abstract
Magnetic resonance imaging (MRI) is often an ideal imaging modality for children of any age for any anatomy and for many pathologies. MRI sequences can be prescribed to produce high-resolution images of anatomical structures, characterize tissue composition, and detect physiological states and organ function. Shortening imaging sequences in any manner possible has been a topic of research and development in MRI since its emergence. Selection of imaging sequence parameters influences more than just the appearance and signal qualities of the imaged tissues; these details along with spatial encoding and data readout steps determine the time it takes to acquire an image. As each piece of image data is acquired and encoded with spatial and temporal information it is stored in k-space. As k-space is filled, either completely or partially, a diagnostic image or physiological data can be reconstructed. Shortening the length of time required for the readout step by efficiently filling k-space using compressed sensing and radial techniques is the subject of this manuscript.
Collapse
Affiliation(s)
- Dianna M E Bardo
- Phoenix Children's Hospital, 1919 E. Thomas Road, Phoenix, AZ, 85016, USA.
| | - Nicholas Rubert
- Phoenix Children's Hospital, 1919 E. Thomas Road, Phoenix, AZ, 85016, USA
| |
Collapse
|
23
|
Compressed SENSE in Pediatric Brain Tumor MR Imaging : Assessment of Image Quality, Examination Time and Energy Release. Clin Neuroradiol 2022; 32:725-733. [PMID: 34994810 PMCID: PMC9424145 DOI: 10.1007/s00062-021-01112-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 10/08/2021] [Indexed: 12/12/2022]
Abstract
Purpose To compare the image quality, examination time, and total energy release of a standardized pediatric brain tumor magnetic resonance imaging (MRI) protocol performed with and without compressed sensitivity encoding (C-SENSE). Recently introduced as an acceleration technique in MRI, we hypothesized that C‑SENSE would improve image quality, reduce the examination time and radiofrequency-induced energy release compared with conventional examination in a pediatric brain tumor protocol. Methods This retrospective study included 22 patients aged 2.33–18.83 years with different brain tumor types who had previously undergone conventional MRI examination and underwent follow-up C‑SENSE examination. Both examinations were conducted with a 3.0-Tesla device and included pre-contrast and post-contrast T1-weighted turbo-field-echo, T2-weighted turbo-spin-echo, and fluid-attenuated inversion recovery sequences. Image quality was assessed in four anatomical regions of interest (tumor area, cerebral cortex, basal ganglia, and posterior fossa) using a 5-point scale. Reader preference between the standard and C‑SENSE images was evaluated. The total examination duration and energy deposit were compared based on scanner log file analysis. Results Relative to standard examinations, C‑SENSE examinations were characterized by shorter total examination times (26.1 ± 3.93 vs. 22.18 ± 2.31 min; P = 0.001), reduced total energy deposit (206.0 ± 19.7 vs. 92.3 ± 18.2 J/kg; P < 0.001), and higher image quality (overall P < 0.001). Conclusion C‑SENSE contributes to the improvement of image quality, reduction of scan times and radiofrequency-induced energy release relative to the standard protocol in pediatric brain tumor MRI. Supplementary Information The online version of this article (10.1007/s00062-021-01112-3) contains supplementary material, which is available to authorized users.
Collapse
|
24
|
Compressed sensing for breath-hold high-resolution hepatobiliary phase imaging: image noise, artifact, biliary anatomy evaluation, and focal lesion detection in comparison with parallel imaging. Abdom Radiol (NY) 2022; 47:133-142. [PMID: 34591152 DOI: 10.1007/s00261-021-03290-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/17/2021] [Accepted: 09/20/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To assess image quality, performance for biliary anatomy diagnosis, and focal lesion detection rate of breath-hold high-resolution 3D T1-weighted hepatobiliary phase imaging using compressed sensing (CS HBP) compared to standard HBP using conventional parallel imaging. METHODS This retrospective study assessed consecutive 125 patients who underwent CS HBP and standard HBP between November 2019 and July 2020. Optimized resolution and scan time for CS HBP were 1 × 1.4 × 1 mm3 and 15 s, while those for standard HBP were 1.3 × 1.8 × 3 mm3 and 16 s. Two independent radiologists evaluated qualitative indices on the clarity of liver margin, visibility of the hepatic vessel and bile duct, image noise, and artifact on a 5-point scale. Biliary anatomy, confidence for biliary anatomy diagnosis, expected number of bile duct openings, and number of focal lesions were assessed. Wilcoxon signed-rank test, Pearson chi-square test, and sensitivity for focal lesion were used for statistical analysis. Intraclass correlation coefficient (ICC) and Cohen's kappa (κ) were used to determine inter-observer agreement. RESULTS CS HBP showed significantly better liver edge sharpness and bile duct visualization, but greater subjective image noise and non-respiratory artifacts compared to standard HBP. CS HBP showed higher number of concordantly assigned biliary anatomy across readers (86 vs. 80), indicating greater inter-observer agreement for biliary anatomy (κ, 0.67 vs. 0.45) and the number of bile duct openings (ICC, 0.860 vs. 0.579) with significantly higher diagnostic confidence (4.70-4.74 vs. 3.96-4.55; p = 0.002). Both readers identified more focal lesions in CS HBP than in standard HBP (88.2% and 84.5% vs. 66.3% and 73.4%). CONCLUSION Breath-hold high-resolution CS HBP was a feasible clinical sequence providing superior liver edge sharpness, bile duct visualization, and focal lesion detection rate compared to standard HBP despite higher noise and artifact. Due to improved spatial resolution, CS HBP yielded a higher inter-observer agreement and confidence for the biliary anatomy diagnosis.
Collapse
|
25
|
Jerjen F, Zaidi T, Chan S, Sharma A, Mudliar R, Soomro K, Jimenez Y, Reed W. Magnetic Resonance Imaging for the diagnosis and management of acute colonic diverticulitis: a review of current and future use. J Med Radiat Sci 2021; 68:310-319. [PMID: 33607699 PMCID: PMC8424307 DOI: 10.1002/jmrs.458] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 12/29/2020] [Accepted: 12/31/2020] [Indexed: 12/14/2022] Open
Abstract
Diverticular disease is one of the most common causes of outpatient visits and hospitalisations across Australia, North America and Europe. According to the Gastroenterological Society of Australia (GESA, 2010), approximately 33% of Australians over 45 years of age and 66% over 85 years of age have some form of colonic diverticulosis. Patients with colonic diverticulosis are known to develop subsequent complications such as acute colonic diverticulitis (ACD), and when more than one attack of diverticulitis occurs, there is a 70-90% chance that the individual will experience ongoing problems and recurring infections throughout their lifetime. Medical imaging is fundamental in the diagnosis, treatment and ongoing management of ACD and its complications, with Computed Tomography (CT) identified as the prevailing gold standard in the last few decades. Cross-database searching highlighted a large gap in the literature regarding the effectiveness of Magnetic Resonance Imaging (MRI) as a non-ionising radiation alternative imaging tool for ACD imaging after the mid-2000s, despite ongoing technological advancements in this modality. This narrative review identified 13 key publications (11 primary prospective cohort studies, 1 systematic review and 1 meta-analysis) that evaluate MRI for ACD imaging, of which five were published within the last decade. Several existing MRI protocols are deemed suitable for ACD imaging, and it is recommended they be re-evaluated in larger cohorts. Future studies should consider the rapidly growing technological improvements of MRI, its cost efficiency and its applicability in modern day healthcare settings when addressing ACD management. This is especially important considering the gradual rise in radiation dose among the Australian population attributable to increased CT referrals, alongside increased reporting of ACD cases in younger individuals.
Collapse
Affiliation(s)
- Franziska Jerjen
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Tooba Zaidi
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Shannon Chan
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Ajay Sharma
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Reuel Mudliar
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Khadija Soomro
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Yobelli Jimenez
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| | - Warren Reed
- Medical Imaging Optimisation and Perception Group (MIOPeG)Discipline of Medical Imaging ScienceSydney School of Health SciencesFaculty of Medicine and HealthFranziska Jerjen and Tooba Zaidi are joint first authorsThe University of SydneySydneyNSWAustralia
| |
Collapse
|
26
|
Glutig K, Mentzel HJ, Prüfer FH, Teichgräber U, Obmann MM, Krämer M. RAVE-T2/T1 - Feasibility of a new hybrid MR-sequence for free-breathing abdominal MRI in children and adolescents. Eur J Radiol 2021; 143:109903. [PMID: 34392003 DOI: 10.1016/j.ejrad.2021.109903] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/22/2021] [Accepted: 08/04/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND The new radial volumetric encoding RAVE-T2/T1 hybrid sequence is a modern three-dimensional sequence with multiparametric approach, which includes T2- and T1-weighted contrasts obtained in identical slice position during one measurement. However, the RAVE-T2/T1 hybrid sequence is not yet being used in clinical routine. PURPOSE The aim of this study was to evaluate the RAVE-T2/T1 hybrid sequence in a pediatric population with a clinical indication for an abdominal MRI examination to demonstrate that the hybrid imaging may be less challenging to perform on children. MATERIALS AND METHODS Our retrospective observational study included pediatric patients of all age groups and required for an abdominal MRI examination. Non-contrast standard axial T1 DIXON and non-contrast RAVE-T2/T1 hybrid sequence were obtained at 3 T. MRI studies were analyzed independently by two pediatric radiologists using a 5-point Likert-type scale in five different categories. T1- and T2-weighted sequences were each compared with the RAVE-T2/T1-sequence using a Wilcoxon signed-rank test. RESULTS The analysis included 15 children (mean age, 11 years and 4 months, 7 girls and 8 boys). The Cohens Kappa of interrater agreement measured 0.62. The T2 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T2 HASTE sequence in four of five image quality categories: overall image quality (2.2 ± 0.7 vs 1.8 ± 0,7, p = 0.03), respiratory motion artefacts (3.8 ± 0.4 vs 2.0 ± 0.7, p <= 0.01), portal vein clarity (3.3 ± 0.8 vs 2.2 ± 0.7, p <= 0.01), hepatic margin sharpness (2.4 ± 1,0 vs 1.8 ± 0.7, p <= 0.01). The T1 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T1 DIXON weighted sequence in three of five image quality categories: respiratory motion artefacts (4.0 ± 0.2 vs 3.6 ± 0.8, p = 0.01), portal vein clarity (2.7 ± 0.9 vs 2.1 ± 0.7, p <= 0.01), hepatic margin sharpness (3.2 ± 0.7 vs 2.6 ± 0.9, p <= 0.01). CONCLUSIONS The RAVE-T2/T1 hybrid sequence is feasible and equal compared to standard T1- and T2-weighted sequences in the assessment of abdominal organs in a pediatric population. Due to non-inferiority to the current standard sequences for abdominal imaging, the RAVE-T2/T1 hybrid sequence is a good alternative for children who cannot be examined in breath-hold technique.
Collapse
Affiliation(s)
- K Glutig
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany.
| | - H-J Mentzel
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| | - F H Prüfer
- University Children's Hospital UKBB, University of Basel, Paediatric Radiology, Spitalstrasse 33, 4031 Basel, Switzerland
| | - U Teichgräber
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| | - M M Obmann
- University Hospital Basel USB, University of Basel, Clinic of Radiology and Nuclear Medicine, Petersgraben 4, 4031 Basel, Switzerland
| | - M Krämer
- Jena University Hospital - Friedrich Schiller University Jena, Institute of Diagnostic and Interventional Radiology, Section of Pediatric Radiology, Am Klinikum 1, 07747 Jena, Germany
| |
Collapse
|
27
|
Artunduaga M, Liu CA, Morin CE, Serai SD, Udayasankar U, Greer MLC, Gee MS. Safety challenges related to the use of sedation and general anesthesia in pediatric patients undergoing magnetic resonance imaging examinations. Pediatr Radiol 2021; 51:724-735. [PMID: 33860861 PMCID: PMC8049862 DOI: 10.1007/s00247-021-05044-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 01/17/2021] [Accepted: 03/01/2021] [Indexed: 12/17/2022]
Abstract
The use of sedation and general anesthesia has facilitated the significant growth of MRI use among children over the last years. While sedation and general anesthesia are considered to be relatively safe, their use poses potential risks in the short term and in the long term. This manuscript reviews the reasons why MRI examinations require sedation and general anesthesia more commonly in the pediatric population, summarizes the safety profile of sedation and general anesthesia, and discusses an amalgam of strategies that can be implemented and can ultimately lead to the optimization of sedation and general anesthesia care within pediatric radiology departments.
Collapse
Affiliation(s)
- Maddy Artunduaga
- Pediatric Radiology Division, Department of Radiology, University of Texas Southwestern Medical Center, Children's Health Medical Center,, 5323 Harry Hines Blvd., CMC F1.02, Dallas, TX, 75390, USA.
- Children's Health Medical Center, Dallas, TX, USA.
| | - C Amber Liu
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Cara E Morin
- Department of Diagnostic Imaging, St. Jude Children's Research Hospital, Memphis, TN, USA
| | - Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA
- Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA
| | - Unni Udayasankar
- Department of Medical Imaging, The University of Arizona Health Sciences, Tucson, AZ, USA
| | - Mary-Louise C Greer
- Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada
- Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Michael S Gee
- Harvard Medical School, Boston, MA, USA
- Department of Radiology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
28
|
Serai SD, Ho ML, Artunduaga M, Chan SS, Chavhan GB. Components of a magnetic resonance imaging system and their relationship to safety and image quality. Pediatr Radiol 2021; 51:716-723. [PMID: 33871725 DOI: 10.1007/s00247-020-04894-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/09/2020] [Accepted: 10/19/2020] [Indexed: 11/24/2022]
Abstract
Magnetic resonance imaging (MRI) is a powerful diagnostic tool that can be optimized to display a wide range of clinical conditions. An MRI system consists of four major components: a main magnet formed by superconducting coils, gradient coils, radiofrequency (RF) coils, and computer systems. Each component has safety considerations. Unless carefully controlled, the MRI machine's strong static magnetic field could turn a ferromagnetic object into a harmful projectile or cause vertigo and headache. Switching magnetic fields in the gradients evokes loud noises in the scanner, which can be mitigated by ear protection. Gradients also generate varying magnetic fields that can cause peripheral nerve stimulation and muscle twitching. Magnetic fields produced by RF coils deposit energy in the body and can cause tissue heating (with the potential to cause skin burns). In this review, we provide an overview of the components of a typical clinical MRI scanner and its associated safety issues. We also discuss how the relationship between the scanning parameters can be manipulated to improve image quality while ensuring a safe operational environment for the patients and staff. Understanding the strengths and limitations of these parameters can enable users to choose optimal techniques for image acquisition, apply them in clinical practice, and improve the diagnostic accuracy of an MRI examination.
Collapse
Affiliation(s)
- Suraj D Serai
- Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA. .,Perelman School of Medicine at the University of Pennsylvania, Philadelphia, PA, USA.
| | - Mai-Lan Ho
- Department of Radiology, Nationwide Children's Hospital, Columbus, OH, USA
| | - Maddy Artunduaga
- Pediatric Radiology Division, Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA.,Children's Health Medical Center, Dallas, TX, USA
| | - Sherwin S Chan
- Department of Radiology, University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA.,Department of Radiology, Children's Mercy Hospital, Kansas City, MO, USA
| | - Govind B Chavhan
- Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto, ON, Canada.,Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
29
|
Serai SD, Panganiban J, Dhyani M, Degnan AJ, Anupindi SA. Imaging Modalities in Pediatric NAFLD. Clin Liver Dis (Hoboken) 2021; 17:200-208. [PMID: 33868666 PMCID: PMC8043697 DOI: 10.1002/cld.994] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 06/05/2020] [Accepted: 06/12/2020] [Indexed: 02/04/2023] Open
Affiliation(s)
- Suraj D. Serai
- Department of RadiologyThe Children’s Hospital of PhiladelphiaPhiladelphiaPA,Perelman School of Medicine at the University of PennsylvaniaPhiladelphiaPA
| | - Jennifer Panganiban
- Department of Gastroenterology, Hepatology and NutritionThe Children's Hospital of PhiladelphiaPhiladelphiaPA
| | - Manish Dhyani
- Department of RadiologyLahey Hospital and Medical CenterBurlingtonMA
| | - Andrew J. Degnan
- Department of RadiologyThe Children’s Hospital of PhiladelphiaPhiladelphiaPA
| | - Sudha A. Anupindi
- Department of RadiologyThe Children’s Hospital of PhiladelphiaPhiladelphiaPA,Perelman School of Medicine at the University of PennsylvaniaPhiladelphiaPA
| |
Collapse
|
30
|
Abstract
OBJECTIVE. The purpose of this article is to review currently available and emerging techniques for pediatric lung MRI for general radiologists. CONCLUSION. MRI is a radiation-free alternative to CT, and clearly understanding the strengths and limitations of established and emerging techniques of pediatric lung MRI can allow practitioners to select and combine the optimal techniques, apply them in clinical practice, and potentially improve early diagnostic accuracy and patient management.
Collapse
|
31
|
Gentle Touch: Noninvasive Approaches to Improve Patient Comfort and Cooperation for Pediatric Imaging. Top Magn Reson Imaging 2021; 29:187-195. [PMID: 32541256 DOI: 10.1097/rmr.0000000000000245] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Pediatric imaging presents unique challenges related to patient anxiety, cooperation, and safety. Techniques to reduce anxiety and patient motion in adults must often be augmented in pediatrics, because it is always mentioned in the field of pediatrics, children are not miniature adults. This article will review methods that can be considered to improve patient experience and cooperation in imaging studies. Such techniques can range from modifications to the scanner suite, different ways of preparing and interacting with children, collaborating with parents for improved patient care, and technical advances such as accelerated acquisition and motion correction to reduce artifact. Special considerations for specific populations including transgender patients, neonates, and pregnant women undergoing fetal imaging will be described. The unique risks of sedation in children will also be briefly reviewed.
Collapse
|