1
|
Hasegawa T, Endo T, Tsuchiya E, Kudo A, Shen Z, Moritani Y, Abe M, Yamamoto T, Hongo H, Tsuboi K, Yoshida T, Nagai T, Khadiza N, Yokoyama A, Luiz de Freitas PH, Li M, Amizuka N. Biological application of focus ion beam-scanning electron microscopy (FIB-SEM) to the imaging of cartilaginous fibrils and osteoblastic cytoplasmic processes. J Oral Biosci 2017. [DOI: 10.1016/j.job.2016.11.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
2
|
Zhang C, Qiu L, Gao L, Guan Y, Xu Q, Zhang X, Chen Q. A novel dual-frequency loading system for studying mechanobiology of load-bearing tissue. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 69:262-7. [PMID: 27612712 DOI: 10.1016/j.msec.2016.06.080] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2016] [Revised: 05/30/2016] [Accepted: 06/25/2016] [Indexed: 01/04/2023]
Abstract
In mechanobiological research, an appropriate loading system is an essential tool to mimic mechanical signals in a native environment. To achieve this goal, we have developed a novel loading system capable of applying dual-frequency loading including both a low-frequency high-amplitude loading and a high-frequency low-amplitude loading, according to the mechanical conditions experienced by bone and articular cartilage tissues. The low-frequency high-amplitude loading embodies the main force from muscular contractions and/or reaction forces while the high-frequency low-amplitude loading represents an assistant force from small muscles, ligaments and/or other tissue in order to maintain body posture during human activities. Therefore, such dual frequency loading system may reflect the natural characteristics of complex mechanical load on bone or articular cartilage than the single frequency loading often applied during current mechanobiological experiments. The dual-frequency loading system is validated by experimental tests using precision miniature plane-mirror interferometers. The dual-frequency loading results in significantly more solute transport in articular cartilage than that of the low-frequency high-amplitude loading regiment alone, as determined by quantitative fluorescence microscopy of tracer distribution in articular cartilage. Thus, the loading system can provide a new method to mimic mechanical environment in bone and cartilage, thereby revealing the in vivo mechanisms of mechanosensation, mechanotransduction and mass-transport, and improving mechanical conditioning of cartilage and/or bone constructs for tissue engineering.
Collapse
Affiliation(s)
- Chunqiu Zhang
- Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin 300384, China; Cell and Molecular Biology Laboratory, Department of Orthopaedics, Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI, USA.
| | - Lulu Qiu
- Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin 300384, China
| | - Lilan Gao
- Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin 300384, China
| | - Yinjie Guan
- Cell and Molecular Biology Laboratory, Department of Orthopaedics, Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI, USA
| | - Qiang Xu
- Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin 300384, China
| | - Xizheng Zhang
- Tianjin Key Laboratory of the Design and Intelligent Control of the Advanced Mechatronical System, Tianjin University of Technology, Tianjin 300384, China
| | - Qian Chen
- Cell and Molecular Biology Laboratory, Department of Orthopaedics, Alpert Medical School of Brown University/Rhode Island Hospital, Providence, RI, USA.
| |
Collapse
|
3
|
Wu M, Gu Z, Xiao J, Feng J. Differential Expression of Apoptosis-Associated Proteins in Chondrocytes of the Mandibular Condyles of Rabbits with Anterior Disk Displacement. Cranio 2014; 26:144-9. [DOI: 10.1179/crn.2008.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
4
|
Xu T, Yang K, You H, Chen A, Wang J, Xu K, Gong C, Shao J, Ma Z, Guo F, Qi J. Regulation of PTHrP expression by cyclic mechanical strain in postnatal growth plate chondrocytes. Bone 2013; 56:304-11. [PMID: 23831868 DOI: 10.1016/j.bone.2013.06.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Revised: 06/25/2013] [Accepted: 06/26/2013] [Indexed: 01/17/2023]
Abstract
Mechanical loading has been widely considered to be a crucial regulatory factor for growth plate development, but the exact mechanisms of this regulation are still not completely understood. In the growth plate, parathyroid hormone-related protein (PTHrP) regulates chondrocyte differentiation and longitudinal growth. Cyclic mechanical strain has been demonstrated to influence growth plate chondrocyte differentiation and metabolism, whereas the relationship between cyclic mechanical strain and PTHrP expression is not clear. The objective of this study was to investigate whether short-term cyclic tensile strain regulates PTHrP expression in postnatal growth plate chondrocytes in vitro and to explore whether the organization of cytoskeletal F-actin microfilaments is involved in this process. To this end, we obtained growth plate chondrocytes from 2-week-old Sprague-Dawley rats and sorted prehypertrophic and hypertrophic chondrocytes using immunomagnetic beads coated with anti-CD200 antibody. The sorted chondrocytes were subjected to cyclic tensile strain of varying magnitude and duration at a frequency of 0.5 Hz. We found that cyclic strain regulates PTHrP expression in a magnitude- and time-dependent manner. Incubation of chondrocytes with cytochalasin D, an actin microfilament-disrupting reagent, blocked the induction of PTHrP expression in response to strain. The results suggest that short-term cyclic tensile strain induces PTHrP expression in postnatal growth plate prehypertrophic and hypertrophic chondrocytes and that PTHrP expression by these chondrocytes may subsequently affect growth plate development. The results also support the idea that the organization of cytoskeletal F-actin microfilaments plays an important role in mechanotransduction.
Collapse
Affiliation(s)
- Tao Xu
- Department of Rehabilitation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, People's Republic of China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Skeletal dysplasias associated with mild myopathy-a clinical and molecular review. J Biomed Biotechnol 2010; 2010:686457. [PMID: 20508815 PMCID: PMC2875749 DOI: 10.1155/2010/686457] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2010] [Accepted: 03/15/2010] [Indexed: 11/17/2022] Open
Abstract
Musculoskeletal system is a complex assembly of tissues which acts as scaffold for the body and enables locomotion. It is often overlooked that different components of this system may biomechanically interact and affect each other. Skeletal dysplasias are diseases predominantly affecting the development of the osseous skeleton. However, in some cases skeletal dysplasia patients are referred to neuromuscular clinics prior to the correct skeletal diagnosis. The muscular complications seen in these cases are usually mild and may stem directly from the muscle defect and/or from the altered interactions between the individual components of the musculoskeletal system. A correct early diagnosis may enable better management of the patients and a better quality of life. This paper attempts to summarise the different components of the musculoskeletal system which are affected in skeletal dysplasias and lists several interesting examples of such diseases in order to enable better understanding of the complexity of human musculoskeletal system.
Collapse
|