1
|
Beekly BG, Rupp A, Burgess CR, Elias CF. Fast neurotransmitter identity of MCH neurons: Do contents depend on context? Front Neuroendocrinol 2023; 70:101069. [PMID: 37149229 PMCID: PMC11190671 DOI: 10.1016/j.yfrne.2023.101069] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Revised: 04/07/2023] [Accepted: 04/29/2023] [Indexed: 05/08/2023]
Abstract
Hypothalamic melanin-concentrating hormone (MCH) neurons participate in many fundamental neuroendocrine processes. While some of their effects can be attributed to MCH itself, others appear to depend on co-released neurotransmitters. Historically, the subject of fast neurotransmitter co-release from MCH neurons has been contentious, with data to support MCH neurons releasing GABA, glutamate, both, and neither. Rather than assuming a position in that debate, this review considers the evidence for all sides and presents an alternative explanation: neurochemical identity, including classical neurotransmitter content, is subject to change. With an emphasis on the variability of experimental details, we posit that MCH neurons may release GABA and/or glutamate at different points according to environmental and contextual factors. Through the lens of the MCH system, we offer evidence that the field of neuroendocrinology would benefit from a more nuanced and dynamic interpretation of neurotransmitter identity.
Collapse
Affiliation(s)
- B G Beekly
- Neuroscience Graduate Program, University of Michigan, Ann Arbor, MI, United States; Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, MI, United States; Elizabeth W. Caswell Diabetes Institute, University of Michigan, Ann Arbor, MI, United States.
| | - A Rupp
- Elizabeth W. Caswell Diabetes Institute, University of Michigan, Ann Arbor, MI, United States
| | - C R Burgess
- Neuroscience Graduate Program, University of Michigan, Ann Arbor, MI, United States; Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, MI, United States; Michigan Neuroscience Institute, University of Michigan, Ann Arbor, MI, United States
| | - C F Elias
- Neuroscience Graduate Program, University of Michigan, Ann Arbor, MI, United States; Department of Molecular and Integrative Physiology, University of Michigan, Ann Arbor, MI, United States; Elizabeth W. Caswell Diabetes Institute, University of Michigan, Ann Arbor, MI, United States
| |
Collapse
|
2
|
Kim H, Baek IY, Seong J. Genetically encoded fluorescent biosensors for GPCR research. Front Cell Dev Biol 2022; 10:1007893. [PMID: 36247000 PMCID: PMC9559200 DOI: 10.3389/fcell.2022.1007893] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Accepted: 09/09/2022] [Indexed: 11/13/2022] Open
Abstract
G protein-coupled receptors (GPCRs) regulate a wide range of physiological and pathophysiological cellular processes, thus it is important to understand how GPCRs are activated and function in various cellular contexts. In particular, the activation process of GPCRs is dynamically regulated upon various extracellular stimuli, and emerging evidence suggests the subcellular functions of GPCRs at endosomes and other organelles. Therefore, precise monitoring of the GPCR activation process with high spatiotemporal resolution is required to investigate the underlying molecular mechanisms of GPCR functions. In this review, we will introduce genetically encoded fluorescent biosensors that can precisely monitor the real-time GPCR activation process in live cells. The process includes the binding of extracellular GPCR ligands, conformational change of GPCR, recruitment of G proteins or β-arrestin, GPCR internalization and trafficking, and the GPCR-related downstream signaling events. We will introduce fluorescent GPCR biosensors based on a variety of strategies such as fluorescent resonance energy transfer (FRET), bioluminescence resonance energy transfer (BRET), circular permuted fluorescent protein (cpFP), and nanobody. We will discuss the pros and cons of these GPCR biosensors as well as their applications in GPCR research.
Collapse
Affiliation(s)
- Hyunbin Kim
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, South Korea
| | - In-Yeop Baek
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Department of Converging Science and Technology, Kyung Hee University, Seoul, South Korea
| | - Jihye Seong
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, South Korea
- Division of Bio-Medical Science and Technology, KIST School, Korea University of Science and Technology, Seoul, South Korea
- Department of Converging Science and Technology, Kyung Hee University, Seoul, South Korea
- *Correspondence: Jihye Seong,
| |
Collapse
|
3
|
Zoghbi ME, Altenberg GA. Luminescence resonance energy transfer spectroscopy of ATP-binding cassette proteins. BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES 2017; 1860:854-867. [PMID: 28801111 DOI: 10.1016/j.bbamem.2017.08.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/02/2017] [Revised: 07/31/2017] [Accepted: 08/01/2017] [Indexed: 12/11/2022]
Abstract
The ATP-binding cassette (ABC) superfamily includes regulatory and transport proteins. Most human ABC exporters pump substrates out of cells using energy from ATP hydrolysis. Although major advances have been made toward understanding the molecular mechanism of ABC exporters, there are still many issues unresolved. During the last few years, luminescence resonance energy transfer has been used to detect conformational changes in real time, with atomic resolution, in isolated ABC nucleotide binding domains (NBDs) and full-length ABC exporters. NBDs are particularly interesting because they provide the power stroke for substrate transport. Luminescence resonance energy transfer (LRET) is a spectroscopic technique that can provide dynamic information with atomic-resolution of protein conformational changes under physiological conditions. Using LRET, it has been shown that NBD dimerization, a critical step in ABC proteins catalytic cycle, requires binding of ATP to two nucleotide binding sites. However, hydrolysis at just one of the sites can drive dissociation of the NBD dimer. It was also found that the NBDs of the bacterial ABC exporter MsbA reconstituted in a lipid bilayer membrane and studied at 37°C never separate as much as suggested by crystal structures. This observation stresses the importance of performing structural/functional studies of ABC exporters under physiologic conditions. This article is part of a Special Issue entitled: Beyond the Structure-Function Horizon of Membrane Proteins edited by Ute Hellmich, Rupak Doshi and Benjamin McIlwain.
Collapse
Affiliation(s)
- Maria E Zoghbi
- School of Natural Sciences, University of California, Merced, 4225 N. Hospital Road, Atwater, CA, USA
| | - Guillermo A Altenberg
- Department of Cell Physiology and Molecular Biophysics, and Center for Membrane Protein Research, Texas Tech University Health Sciences Center, Lubbock, TX 79423-6551, USA.
| |
Collapse
|
4
|
De Michele R, Ast C, Loqué D, Ho CH, Andrade SLA, Lanquar V, Grossmann G, Gehne S, Kumke MU, Frommer WB. Fluorescent sensors reporting the activity of ammonium transceptors in live cells. eLife 2013; 2:e00800. [PMID: 23840931 PMCID: PMC3699834 DOI: 10.7554/elife.00800] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2013] [Accepted: 05/18/2013] [Indexed: 01/14/2023] Open
Abstract
Ammonium serves as key nitrogen source and metabolic intermediate, yet excess causes toxicity. Ammonium uptake is mediated by ammonium transporters, whose regulation is poorly understood. While transport can easily be characterized in heterologous systems, measuring transporter activity in vivo remains challenging. Here we developed a simple assay for monitoring activity in vivo by inserting circularly-permutated GFP into conformation-sensitive positions of two plant and one yeast ammonium transceptors (‘AmTrac’ and ‘MepTrac’). Addition of ammonium to yeast cells expressing the sensors triggered concentration-dependent fluorescence intensity (FI) changes that strictly correlated with the activity of the transporter. Fluorescence-based activity sensors present a novel technology for monitoring the interaction of the transporters with their substrates, the activity of transporters and their regulation in vivo, which is particularly valuable in the context of analytes for which no radiotracers exist, as well as for cell-specific and subcellular transport processes that are otherwise difficult to track. DOI:http://dx.doi.org/10.7554/eLife.00800.001 Ammonium provides a vital source of nitrogen for bacteria, fungi and plants, and is produced by animals as a waste product of metabolism. High levels of ammonium can be toxic, so all organisms need to control their uptake or excretion of this substance. Ammonium transporters, which are highly conserved from bacteria to plants to humans, are essential for this process but, along with transporters in general, they are hard to study. Their activity can be examined in vitro by expressing them in heterologous systems—that is, in cells other than those in which they are naturally found. But in vivo studies must rely on indirect techniques such as monitoring radioactive isotopes or membrane potentials, and these cannot distinguish between the activity of ammonium transporters and uptake of ammonium through other routes. One approach that has been successful in other fields is the use of fluorescent proteins that can signal conformational changes—such as those that occur when a transporter is activated—by a shift in fluorescence. Green fluorescent protein (GFP) is a commonly used fluorescent indicator, and a particularly useful variant is ‘circularly permutated GFP’. This is GFP in which parts of the amino acid sequence have been rearranged without fundamentally changing the overall structure or function of the protein. Circularly permutated GFP can be fused to another protein in such a way that a conformational change in the second protein triggers a change in fluorescence that can be detected by fluorescence spectroscopy or microscopy. Now, De Michele et al. have applied this approach to the study of both plant and yeast ammonium transporters. They constructed a library of fusion proteins made up of circularly permutated GFP and an ammonium transporter from the plant Arabidopsis thaliana—and found one version that functioned normally as a transporter but also produced a detectable change in fluorescence that correlated precisely with transporter activity. De Michele et al. then used the same method to produce fluorescent indicator fusion proteins of two more ammonium transporters—a second isoform from Arabidopsis and one from yeast. These fluorescent sensors should be a great boon to researchers studying the ammonium transport system. Moreover, this approach could in theory be applied to other transporter proteins that are currently difficult to study, and so could help to open up research into a variety of transport processes. DOI:http://dx.doi.org/10.7554/eLife.00800.002
Collapse
Affiliation(s)
- Roberto De Michele
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States.,Institute of Plant Genetics, Italian National Research Council (CNR-IGV), Palermo, Italy
| | - Cindy Ast
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States.,NanoPolyPhotonik, Fraunhofer Institute for Applied Polymer Research, Potsdam-Golm, Germany
| | - Dominique Loqué
- Feedstocks Division, Joint BioEnergy Institute, Emeryville, United States
| | - Cheng-Hsun Ho
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Susana LA Andrade
- Department of Biochemistry, Institute for Organic Chemistry and Biochemistry, and BIOSS Center for Biological Signalling Studies, University of Freiburg, Freiburg, Germany
| | - Viviane Lanquar
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Guido Grossmann
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Sören Gehne
- Department of Physical Chemistry, Institute of Chemistry, University of Potsdam, Potsdam, Germany
| | - Michael U Kumke
- Department of Physical Chemistry, Institute of Chemistry, University of Potsdam, Potsdam, Germany
| | - Wolf B Frommer
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| |
Collapse
|
5
|
De Michele R, Ast C, Loqué D, Ho CH, Andrade SLA, Lanquar V, Grossmann G, Gehne S, Kumke MU, Frommer WB. Fluorescent sensors reporting the activity of ammonium transceptors in live cells. eLife 2013; 2:e00800. [PMID: 23840931 DOI: 10.7554/elife.00800.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2013] [Accepted: 05/18/2013] [Indexed: 05/26/2023] Open
Abstract
Ammonium serves as key nitrogen source and metabolic intermediate, yet excess causes toxicity. Ammonium uptake is mediated by ammonium transporters, whose regulation is poorly understood. While transport can easily be characterized in heterologous systems, measuring transporter activity in vivo remains challenging. Here we developed a simple assay for monitoring activity in vivo by inserting circularly-permutated GFP into conformation-sensitive positions of two plant and one yeast ammonium transceptors ('AmTrac' and 'MepTrac'). Addition of ammonium to yeast cells expressing the sensors triggered concentration-dependent fluorescence intensity (FI) changes that strictly correlated with the activity of the transporter. Fluorescence-based activity sensors present a novel technology for monitoring the interaction of the transporters with their substrates, the activity of transporters and their regulation in vivo, which is particularly valuable in the context of analytes for which no radiotracers exist, as well as for cell-specific and subcellular transport processes that are otherwise difficult to track. DOI:http://dx.doi.org/10.7554/eLife.00800.001.
Collapse
Affiliation(s)
- Roberto De Michele
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
- Institute of Plant Genetics, Italian National Research Council (CNR-IGV), Palermo, Italy
| | - Cindy Ast
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
- NanoPolyPhotonik, Fraunhofer Institute for Applied Polymer Research, Potsdam-Golm, Germany
| | - Dominique Loqué
- Feedstocks Division, Joint BioEnergy Institute, Emeryville, United States
| | - Cheng-Hsun Ho
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Susana LA Andrade
- Department of Biochemistry, Institute for Organic Chemistry and Biochemistry, and BIOSS Center for Biological Signalling Studies, University of Freiburg, Freiburg, Germany
| | - Viviane Lanquar
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Guido Grossmann
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| | - Sören Gehne
- Department of Physical Chemistry, Institute of Chemistry, University of Potsdam, Potsdam, Germany
| | - Michael U Kumke
- Department of Physical Chemistry, Institute of Chemistry, University of Potsdam, Potsdam, Germany
| | - Wolf B Frommer
- Department of Plant Biology, Carnegie Institution for Science, Stanford, United States
| |
Collapse
|
6
|
In vivo biochemistry: quantifying ion and metabolite levels in individual cells or cultures of yeast. Biochem J 2011; 438:1-10. [PMID: 21793803 DOI: 10.1042/bj20110428] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Over the past decade, we have learned that cellular processes, including signalling and metabolism, are highly compartmentalized, and that relevant changes in metabolic state can occur at sub-second timescales. Moreover, we have learned that individual cells in populations, or as part of a tissue, exist in different states. If we want to understand metabolic processes and signalling better, it will be necessary to measure biochemical and biophysical responses of individual cells with high temporal and spatial resolution. Fluorescence imaging has revolutionized all aspects of biology since it has the potential to provide information on the cellular and subcellular distribution of ions and metabolites with sub-second time resolution. In the present review we summarize recent progress in quantifying ions and metabolites in populations of yeast cells as well as in individual yeast cells with the help of quantitative fluorescent indicators, namely FRET metabolite sensors. We discuss the opportunities and potential pitfalls and the controls that help preclude misinterpretation.
Collapse
|
7
|
Kaláb P, Soderholm J. The design of Förster (fluorescence) resonance energy transfer (FRET)-based molecular sensors for Ran GTPase. Methods 2010; 51:220-32. [PMID: 20096786 DOI: 10.1016/j.ymeth.2010.01.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2010] [Accepted: 01/19/2010] [Indexed: 01/01/2023] Open
Abstract
The application of FRET-based molecular biosensors provided confirmation of the central model of Ran GTPase function and led to important new insights into its physiological role. In many fields of cell biology, methods employing FRET are a standard approach that is becoming increasingly accessible due to advances in instrumentation and available fluorophores. However, the optimal design of a FRET sensor remains to be the cornerstone of any successful FRET application. Utilizing the recent literature on FRET applications and our studies on Ran, we outline the basic considerations involved in designing molecular FRET sensors. We point to several broadly applicable principles that were used in many different FRET sensors that can detect a wide range of molecular events. Using the FRET sensors for Ran that we created as examples, we then focus on the practical aspects of FRET assays. We describe the preparation of a bipartite FRET sensor consisting of ECFP-Ran and EYFP-importin beta and its validation as a reporter for FRET-based high throughput screening in small molecule libraries. Finally, we review the design and optimization of monomolecular FRET sensors that monitor the RanGTP-RanBP1 interaction, and of sensors detecting the RanGTP-regulated importin beta cargo release.
Collapse
Affiliation(s)
- Petr Kaláb
- National Cancer Institute, NIH, Bethesda, MD 20892-4256, USA.
| | | |
Collapse
|
8
|
Sunbul M, Yin J. Site specific protein labeling by enzymatic posttranslational modification. Org Biomol Chem 2009; 7:3361-71. [DOI: 10.1039/b908687k] [Citation(s) in RCA: 78] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
|
9
|
Niittylae T, Chaudhuri B, Sauer U, Frommer WB. Comparison of quantitative metabolite imaging tools and carbon-13 techniques for fluxomics. Methods Mol Biol 2009; 553:355-72. [PMID: 19588116 DOI: 10.1007/978-1-60327-563-7_19] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
The recent development of analytic technologies allows fast analysis of metabolism in real time. Fluxomics aims to define the genes involved in regulation of flux through a metabolic or signaling pathway. Flux through a metabolic or signaling pathway is determined by the activity of its individual components; regulation can occur at many levels, including transcriptional, posttranslational, and allosteric levels. Currently two technologies are used to monitor fluxes. The first is pulse labeling of the organism with a tracer such as C13, followed by mass spectrometric analysis of the partitioning of label into different compounds. The second approach is based on the use of flux sensors, proteins that respond with a conformational change to ligand binding. Fluorescence resonance energy transfer (FRET) detects the conformational change and serves as a proxy for ligand concentration. Both methods provide high time resolution. In contrast to mass spectrometry assays, FRET nanosensors monitor only a single compound, but the advantage of FRET nanosensors is that they yield data with cellular and subcellular resolution.
Collapse
Affiliation(s)
- Totte Niittylae
- Department of Plant Biology, Carnegie Institution for Science, Stanford, CA, USA
| | | | | | | |
Collapse
|
10
|
Rebois RV, Robitaille M, Pétrin D, Zylbergold P, Trieu P, Hébert TE. Combining protein complementation assays with resonance energy transfer to detect multipartner protein complexes in living cells. Methods 2008; 45:214-8. [DOI: 10.1016/j.ymeth.2008.06.006] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2008] [Accepted: 06/16/2008] [Indexed: 10/21/2022] Open
|
11
|
Niesner RA, Andresen V, Gunzer M. Intravital two-photon microscopy: focus on speed and time resolved imaging modalities. Immunol Rev 2008; 221:7-25. [PMID: 18275472 DOI: 10.1111/j.1600-065x.2008.00582.x] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Initially used mainly in the neurosciences, two-photon microscopy has become a powerful tool for the analysis of immunological processes. Here, we describe currently available two-photon microscopy techniques with a focus on novel approaches that allow very high image acquisition rates compared with state-of-the-art systems. This improvement is achieved through a parallelization of the excitation process: multiple beams scan the sample simultaneously, and the fluorescence is collected with sensitive charge-coupled device (CCD)-based line or field detectors. The new technique's performance is compared with conventional single beam laser-scanning systems that detect signals by means of photomultipliers. We also discuss the use of time- and polarization-resolved fluorescence detection, especially fluorescence lifetime imaging (FLIM), which goes beyond simple detection of cells and tissue structures and allows insight into cellular physiology. We focus on the analysis of endogenous fluorophores such as NAD(P)H as a way to analyze the redox status in cells with subcellular resolution. Here, high-speed imaging setups in combination with novel ways of data analysis allow the generation of FLIM data sets almost in real time. The implications of this technology for the analysis of immune reactions and other cellular processes are discussed.
Collapse
Affiliation(s)
- Raluca A Niesner
- Junior Research Group Immunodynamics, Helmholtz Centre for Infection Research, Braunschweig, Germany
| | | | | |
Collapse
|
12
|
Deerinck TJ. The application of fluorescent quantum dots to confocal, multiphoton, and electron microscopic imaging. Toxicol Pathol 2008; 36:112-6. [PMID: 18337229 DOI: 10.1177/0192623307310950] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Fluorescent quantum dots are emerging as an important tool for imaging cells and tissues, and their unique optical and physical properties have captured the attention of the research community. The most common types of commercially available quantum dots consist of a nanocrystalline semiconductor core composed of cadmium selenide with a zinc sulfide capping layer and an outer polymer layer to facilitate conjugation to targeting biomolecules such as immunoglobulins. They exhibit high fluorescent quantum yields and have large absorption cross-sections, possess excellent photostability, and can be synthesized so that their narrow-band fluorescence emission can occur in a wide spectrum of colors. These properties make them excellent candidates for serving as multiplexing molecular beacons using a variety of imaging modalities including highly correlated microscopies. Whereas much attention has been focused on quantum-dot applications for live-cell imaging, we have sought to characterize and exploit their utility for enabling simultaneous multiprotein immunolabeling in fixed cells and tissues. Considerations for their application to immunolabeling for correlated light and electron microscopic analysis are discussed.
Collapse
Affiliation(s)
- Thomas J Deerinck
- National Center of Microscopy and Imaging Research (NCMIR), Center for Research on Biological Systems, University of California, San Diego (UCSD) School of Medicine, 1000 BSB, 9500 Gilman Drive, MC0608, La Jolla, CA 92093-0608, USA.
| |
Collapse
|
13
|
Kalab P, Pralle A. Chapter 21 Quantitative Fluorescence Lifetime Imaging in Cells as a Tool to Design Computational Models of Ran‐Regulated Reaction Networks. Methods Cell Biol 2008; 89:541-68. [DOI: 10.1016/s0091-679x(08)00621-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
14
|
Jones PB, Rozkalne A, Meyer-Luehmann M, Spires-Jones TL, Makarova A, Kumar ATN, Berezovska O, Bacskai BB, Hyman BT. Two postprocessing techniques for the elimination of background autofluorescence for fluorescence lifetime imaging microscopy. JOURNAL OF BIOMEDICAL OPTICS 2008; 13:014008. [PMID: 18315366 DOI: 10.1117/1.2837169] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
The analysis of fluorescence lifetime imaging microscopy (FLIM) data under complex biological conditions can be challenging. Particularly, the presence of short-lived autofluorescent aggregates can confound lifetime measurements in fluorescence energy transfer (FRET) experiments, where it can become confused with the signal from exogenous fluorophores. Here we report two techniques that can be used to discriminate the contribution of autofluorescence from exogenous fluorphores in FLIM. We apply the techniques to transgenic mice that natively express yellow fluorescence protein (YFP) in a subset of cortical neurons and to histological slices of aged human brain tissue, where we study the misfolding of intracellular tau protein in the form of neurofibrillary tangles.
Collapse
Affiliation(s)
- Phillip B Jones
- Harvard Medical School, Massachusetts General Hospital, MassGeneral Institute for Neurodegenerative Disorders, 114 16th Street, Charlestown, Massachusetts 02129, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Okumoto S, Takanaga H, Frommer WB. Quantitative imaging for discovery and assembly of the metabo-regulome. THE NEW PHYTOLOGIST 2008; 180:271-295. [PMID: 19138219 PMCID: PMC2663047 DOI: 10.1111/j.1469-8137.2008.02611.x] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Little is known about regulatory networks that control metabolic flux in plant cells. Detailed understanding of regulation is crucial for synthetic biology. The difficulty of measuring metabolites with cellular and subcellular precision is a major roadblock. New tools have been developed for monitoring extracellular, cytosolic, organellar and vacuolar ion and metabolite concentrations with a time resolution of milliseconds to hours. Genetically encoded sensors allow quantitative measurement of steady-state concentrations of ions, signaling molecules and metabolites and their respective changes over time. Fluorescence resonance energy transfer (FRET) sensors exploit conformational changes in polypeptides as a proxy for analyte concentrations. Subtle effects of analyte binding on the conformation of the recognition element are translated into a FRET change between two fused green fluorescent protein (GFP) variants, enabling simple monitoring of analyte concentrations using fluorimetry or fluorescence microscopy. Fluorimetry provides information averaged over cell populations, while microscopy detects differences between cells or populations of cells. The genetically encoded sensors can be targeted to subcellular compartments or the cell surface. Confocal microscopy ultimately permits observation of gradients or local differences within a compartment. The FRET assays can be adapted to high-throughput analysis to screen mutant populations in order to systematically identify signaling networks that control individual steps in metabolic flux.
Collapse
Affiliation(s)
- Sakiko Okumoto
- Plant Pathology, Physiology, and Weed Science Department, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061, USA
| | - Hitomi Takanaga
- Carnegie Institution for Science, Department of Plant Biology, 260 Panama St., Stanford, CA 94305, USA
| | - Wolf B. Frommer
- Carnegie Institution for Science, Department of Plant Biology, 260 Panama St., Stanford, CA 94305, USA
- Joint Bioenergy Institute, Feedstocks Division, Emerystation East, 5885 Hollis Street Emeryville, CA 94608, USA
| |
Collapse
|