1
|
Abstract
The “Guideline for Prevention of Intravascular Device-Related Infections” is designed to reduce the incidence of intravascular device-related infections by providing an over view of the evidence for recommendations considered prudent by consensus of Hospital Infection Control Practices Advisor y Committee (HICPAC) members. This two-part document updates and replaces the previously published Centers for Disease Control's (CDC) Guideline for Intravascular Infections (Am J Infect Control1983;11:183-199). Part I, “Intravascular Device-Related Infections: An Over view” discusses many of the issues and controversies in intravascular-device use and maintenance. These issues include definitions and diagnosis of catheter-related infection, appropriate barrier precautions during catheter insertion, inter vals for replacement of catheters, intravenous (IV) fluids and administration sets, catheter-site care, the role of specialized IV personnel, and the use of prophylactic antimi-crobials, flush solutions, and anticoagulants. Part II, “Recommendations for Prevention of Intravascular Device-Related Infections” provides consensus recommendations of the HICPAC for the prevention and control of intravascular device-related infections. A working draft of this document also was reviewed by experts in hospital infection control, internal medicine, pediatrics, and intravenous therapy. However, all recommendations contained in the guideline may not reflect the opinion of all reviewers.
Collapse
|
2
|
Abstract
Background:Although many catheter-related blood-stream infections (CRBSIs) are preventable, measures to reduce these infections are not uniformly implemented.Objective:To update an existing evidenced-based guideline that promotes strategies to prevent CRBSIs.Data Sources:The MEDLINE database, conference proceedings, and bibliographies of review articles and book chapters were searched for relevant articles.Studies Included:Laboratory-based studies, controlled clinical trials, prospective interventional trials, and epidemiologic investigations.Outcome Measures:Reduction in CRBSI, catheter colonization, or catheter-related infection.Synthesis:The recommended preventive strategies with the strongest supportive evidence are education and training of healthcare providers who insert and maintain catheters; maximal sterile barrier precautions during central venous catheter insertion; use of a 2% chlorhexidine preparation for skin antisepsis; no routine replacement of central venous catheters for prevention of infection; and use of antiseptic/antibiotic-impregnated short-term central venous catheters if the rate of infection is high despite adherence to other strategies (ie, education and training, maximal sterile barrier precautions, and 2% chlorhexidine for skin antisepsis).Conclusion:Successful implementation of these evidence-based interventions can reduce the risk for serious catheter-related infection.
Collapse
|
3
|
O'Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S. Summary of recommendations: Guidelines for the Prevention of Intravascular Catheter-related Infections. Clin Infect Dis 2011; 52:1087-99. [PMID: 21467014 DOI: 10.1093/cid/cir138] [Citation(s) in RCA: 313] [Impact Index Per Article: 24.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Naomi P O'Grady
- Critical Care Medicine Department, National Institutes of Health, Bethesda, Maryland, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
O'Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 2011; 39:S1-34. [PMID: 21511081 DOI: 10.1016/j.ajic.2011.01.003] [Citation(s) in RCA: 696] [Impact Index Per Article: 53.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Revised: 02/03/2011] [Accepted: 02/04/2011] [Indexed: 12/14/2022]
Affiliation(s)
- Naomi P O'Grady
- Critical Care Medicine Department, National Institutes of Health, Bethesda, Maryland 20892, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
O'Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S. Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis 2011; 52:e162-93. [PMID: 21460264 DOI: 10.1093/cid/cir257] [Citation(s) in RCA: 1202] [Impact Index Per Article: 92.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Affiliation(s)
- Naomi P O'Grady
- Critical Care Medicine Department, National Institutes of Health, Bethesda, Maryland
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
6
|
[Recommendation for the prevention of nosocomial infections in neonatal intensive care patients with a birth weight less than 1,500 g. Report by the Committee of Hospital Hygiene and Infection Prevention of the Robert Koch Institute]. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2008. [PMID: 18041117 PMCID: PMC7080031 DOI: 10.1007/s00103-007-0337-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
7
|
Maki DG, Crnich CJ, Safdar N. Nosocomial Infection in the Intensive Care Unit. Crit Care Med 2008. [PMID: 18431302 PMCID: PMC7170205 DOI: 10.1016/b978-032304841-5.50053-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
8
|
O'Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, Masur H, McCormick RD, Mermel LA, Pearson ML, Raad II, Randolph A, Weinstein RA. Guidelines for the prevention of intravascular catheter-related infections. Infect Control Hosp Epidemiol 2002; 23:759-69. [PMID: 12517020 DOI: 10.1086/502007] [Citation(s) in RCA: 248] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND Although many catheter-related bloodstream infections (CRBSIs) are preventable, measures to reduce these infections are not uniformly implemented. OBJECTIVE To update an existing evidenced-based guideline that promotes strategies to prevent CRBSIs. DATA SOURCES The MEDLINE database, conference proceedings, and bibliographies of review articles and book chapters were searched for relevant articles. STUDIES INCLUDED Laboratory-based studies, controlled clinical trials, prospective interventional trials, and epidemiologic investigations. OUTCOME MEASURES Reduction in CRBSI, catheter colonization, or catheter-related infection. SYNTHESIS The recommended preventive strategies with the strongest supportive evidence are education and training of healthcare providers who insert and maintain catheters; maximal sterile barrier precautions during central venous catheter insertion; use of a 2% chlorhexidine preparation for skin antisepsis; no routine replacement of central venous catheters for prevention of infection; and use of antiseptic/antibiotic-impregnated short-term central venous catheters if the rate of infection is high despite adherence to other strategies (ie, education and training, maximal sterile barrier precautions, and 2% chlorhexidine for skin antisepsis). CONCLUSION Successful implementation of these evidence-based interventions can reduce the risk for serious catheter-related infection.
Collapse
Affiliation(s)
- Naomi P O'Grady
- Clinical Center, National Institutes of Health, Bethesda, Maryland, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
O'Grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, Masur H, McCormick RD, Mermel LA, Pearson ML, Raad II, Randolph A, Weinstein RA. Guidelines for the Prevention of Intravascular Catheter–Related Infections. Clin Infect Dis 2002. [DOI: 10.1086/344188] [Citation(s) in RCA: 161] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
AbstractThese guidelines have been developed for practitioners who insert catheters and for persons responsible for surveillance and control of infections in hospital, outpatient, and home health-care settings. This report was prepared by a working group comprising members from professional organizations representing the disciplines of critical care medicine, infectious diseases, health-care infection control, surgery, anesthesiology, interventional radiology, pulmonary medicine, pediatric medicine, and nursing. The working group was led by the Society of Critical Care Medicine (SCCM), in collaboration with the Infectious Disease Society of America (IDSA), Society for Healthcare Epidemiology of America (SHEA), Surgical Infection Society (SIS), American College of Chest Physicians (ACCP), American Thoracic Society (ATS), American Society of Critical Care Anesthesiologists (ASCCA), Association for Professionals in Infection Control and Epidemiology (APIC), Infusion Nurses Society (INS), Oncology Nursing Society (ONS), Society of Cardiovascular and Interventional Radiology (SCVIR), American Academy of Pediatrics (AAP), and the Healthcare Infection Control Practices Advisory Committee (HICPAC) of the Centers for Disease Control and Prevention (CDC) and is intended to replace the Guideline for Prevention of Intravascular Device–Related Infections published in 1996. These guidelines are intended to provide evidence-based recommendations for preventing catheter-related infections. Major areas of emphasis include 1) educating and training health-care providers who insert and maintain catheters; 2) using maximal sterile barrier precautions during central venous catheter insertion; 3) using a 2% chlorhexidine preparation for skin antisepsis; 4) avoiding routine replacement of central venous catheters as a strategy to prevent infection; and 5) using antiseptic/antibiotic impregnated short-term central venous catheters if the rate of infection is high despite adherence to other strategies (i.e., education and training, maximal sterile barrier precautions, and 2% chlorhexidine for skin antisepsis). These guidelines also identify performance indicators that can be used locally by health-care institutions or organizations to monitor their success in implementing these evidence-based recommendations.
Collapse
Affiliation(s)
| | | | | | - Julie L. Gerberding
- Office of the Director, Centers for Disease Control and Prevention (CDC), CDC, Atlanta, Georgia
| | | | | | - Henry Masur
- National Institutes of Health, Bethesda, Maryland
| | | | - Leonard A. Mermel
- Rhode Island Hospital and Brown University School of Medicine, Providence, Rhode Island
| | - Michele L. Pearson
- Division of Healthcare Quality Promotion, National Center for Infectious Diseases, CDC, Atlanta, Georgia
| | | | | | | |
Collapse
|
10
|
O'grady NP, Alexander M, Dellinger EP, Gerberding JL, Heard SO, Maki DG, Masur H, McCormick RD, Mermel LA, Pearson ML, Raad II, Randolph A, Weinstein RA. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control 2002; 30:476-89. [PMID: 12461511 DOI: 10.1067/mic.2002.129427] [Citation(s) in RCA: 162] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND Although many catheter-related bloodstream infections (CR-BSIs) are preventable, measures to reduce these infections are not uniformly implemented. OBJECTIVE To update an existing evidenced-based guideline that promotes strategies to prevent CR-BSIs. DATA SOURCES The MEDLINE database, conference proceedings, and bibliographies of review articles and book chapters were searched for relevant articles.Studies Included: Laboratory-based studies, controlled clinical trials, prospective interventional trials, and epidemiological investigations. OUTCOME MEASURES Reduction in CR-BSI, catheter colonization, or catheter-related infection. SYNTHESIS The recommended preventive strategies with the strongest supportive evidence are education and training of healthcare providers who insert and maintain catheters; maximal sterile barrier precautions during central venous catheter insertion; use of a 2% chlorhexidine preparation for skin antisepsis; no routine replacement of central venous catheters for prevention of infection; and use of antiseptic/antibiotic impregnated short-term central venous catheters if the rate of infection is high despite adherence to other strategies (i.e. education and training, maximal sterile barrier precautions and 2% chlorhexidine for skin antisepsis). CONCLUSION Successful implementation of these evidence-based interventions can reduce the risk for serious catheter-related infection.
Collapse
Affiliation(s)
- Naomi P O'grady
- Clinical Center, National Institutes of Health, Bethesda, MD, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Measuring "hang time": Contamination of intra-arterial flush solutions over time. Dimens Crit Care Nurs 2001; 20:38-41. [DOI: 10.1097/00003465-200111000-00010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
12
|
Pearson ML. Guideline for Prevention of Intravascular-Device-Related Infections. Infect Control Hosp Epidemiol 1996. [DOI: 10.2307/30141155] [Citation(s) in RCA: 162] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
13
|
Gardner RM. Accuracy and reliability of disposable pressure transducers coupled with modern pressure monitors. Crit Care Med 1996; 24:879-82. [PMID: 8706469 DOI: 10.1097/00003246-199605000-00025] [Citation(s) in RCA: 25] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
OBJECTIVE To determine the bedside accuracy of direct patient pressure monitoring when used with new and clinically used disposable blood pressure (BP) transducers. DESIGN Prospective study. SETTING Laboratory bench and critical care units in an adult and children's hospital. SUBJECTS Seventy-five bedside patient monitors (25 Marquette Electronics, 25 Spacelab Medical, and 25 Hewlett-Packard), and 100 disposable transducers (50 from Utah Medical Products and 50 from Abbott Critical Care Systems [25 new, 25 clinically used of each manufacturer]) were tested. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS A +/- 2% accuracy requirement for bedside monitors and the +/- 3% American National Standards Institute accuracy standard for disposable BP transducers were used. To test the accuracy of the bedside monitors, a certified transducer simulator was used to apply 100 mm Hg to each bedside monitor. To test the accuracy of the disposable BP transducers, a very accurate (+/- 0.05%) pneumatic dead weight tester was used to apply pressures to the transducer. A digital power supply and a 6 1/2 digit voltmeter were used. The average output of the bedside monitors when 100 mm Hg was applied was 99.90 +/- 0.83 mm Hg, with the worst cases being 98 and 103 mm Hg. For all 100 disposable pressure transducers, the average output was 100.03 +/- 0.55 mm Hg, with the worst cases being 98.53 and 101.36 when 100 mm Hg was applied. There was no important difference in the accuracy of the transducers obtained from the two vendors nor whether the transducers had been used clinically. CONCLUSIONS All disposable BP transducers tested were much more accurate than the American National Standards Institute standard for accuracy. Even the worst case transducers were twice as accurate as required by the American National Standards Institute standard. Only one bedside monitor was outside the +/- 2% accuracy range (103 mm Hg). Based on these findings, this author recommends that fixed calibration disposable transducers and fixed calibration bedside pressure monitoring systems be used. The clinical risks of air embolism and infection from the calibrating mercury manometer and the complexity of the calibration task are the overriding factors for making these recommendations.
Collapse
Affiliation(s)
- R M Gardner
- Department of Medical Informatics, LDS Hospital, Salt Lake City, UT 84143, USA
| |
Collapse
|
14
|
Ransjö U, Good Z, Jalakas K, Kühn I, Siggelkow I, Aberg B, Anjou E. An outbreak of Klebsiella oxytoca septicemias associated with the use of invasive blood pressure monitoring equipment. Acta Anaesthesiol Scand 1992; 36:289-91. [PMID: 1574979 DOI: 10.1111/j.1399-6576.1992.tb03466.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Seven cases of septicemia with piperacillin-resistant Klebsiella oxytoca (PRKO) occurred at 2-monthly intervals in a thoracic surgery intensive care unit. All PRKO isolates were serotyped, and phenotyped with a biochemical typing system. Only one patient in the unit was found to be colonized in stool or respiratory tract with PRKO, and this strain was different from the septicemia strains in phenotype though not in serotype. Environmental cultures, from humidifiers, oxygenators, pressure transducers, etc. were negative. PRKO of the epidemic phenotype was recovered from several non-patient transducer domes. The outbreak ended when transducer heads were disinfected and the use of non-patient domes was abolished.
Collapse
Affiliation(s)
- U Ransjö
- Department of Clinical Microbiology, Karolinska Hospital, Stockholm, Sweden
| | | | | | | | | | | | | |
Collapse
|
15
|
Mermel LA, McCormick RD, Springman SR, Maki DG. The pathogenesis and epidemiology of catheter-related infection with pulmonary artery Swan-Ganz catheters: a prospective study utilizing molecular subtyping. Am J Med 1991; 91:197S-205S. [PMID: 1928165 DOI: 10.1016/0002-9343(91)90369-9] [Citation(s) in RCA: 261] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
To delineate the pathogenesis and epidemiology of catheter-related infection with Swan-Ganz pulmonary artery (PA) catheters, a prospective clinical study of hospitalized adult medical and surgical patients was done. Role of catheter material was assessed by randomizing insertions to heparin-bonded PA catheters made of polyvinylchloride or polyurethane. Sources of infection and pathogenesis were studied by culturing skin, the introducer, the PA catheter tip, all hubs, infusate from each lumen, and the extravascular portion of the PA catheter beneath the external protective plastic sleeve. Concordance between isolates from sources and infected catheters was determined by speciation, antibiogram, and for coagulase-negative staphylococci, plasmid profile analysis. Risk factors for infection were determined by stepwise logistic regression. Overall, 65 (22%) of 297 Swan-Ganz catheters showed local infection of the introducer (58 catheters) or the intravascular portion of the PA catheter (20 catheters); only two catheters (0.7%) caused bacteremia. Eighty percent of infected Swan-Ganz catheters (the introducer or PA catheter) showed concordance with organisms cultured from skin of the insertion site, 17% with a contaminated hub and 18% with organisms contaminating the extravascular portion of the PA catheter beneath the sleeve. Isolates from infected PA catheters were most likely to show concordance with concomitantly infected introducers (71%). Cutaneous colonization of the insertion site with greater than 10(2) cfu/10 cm2 (relative risk [RR] 5.5; p less than 0.001), insertion into an internal jugular vein (RR 4.3; p less than 0.01), catheterization greater than 3 days (RR 3.1; p less than 0.01), and insertion in the operating room using less stringent barrier precautions (RR 2.1; p = 0.03) were each associated with a significantly increased risk of catheter-related infection. The risk of bacteremic infection with Swan-Ganz catheters is now low, in the range of 1%, with reasonable care. Swan-Ganz catheters are vulnerable to contamination from multiple sources, but the patient's skin is the single most important source of organisms causing invasive infection, which in most cases involves the introducer rather than the PA catheter. Heavy colonization of the insertion site, percutaneous insertion in the internal jugular vein rather than subclavian vein, catheterization longer than 3 days, and insertion with less stringent barrier precautions significantly increase the risk of catheter-related infection. These findings hold promise for application to management of Swan-Ganz catheters and research in catheter design to reduce the risk of catheter-related infection.
Collapse
Affiliation(s)
- L A Mermel
- Department of Medicine, University of Wisconsin Medical School, Madison
| | | | | | | |
Collapse
|
16
|
Crow S, Conrad SA, Chaney-Rowell C, King JW. Microbial Contamination of Arterial Infusions Used for Hemodynamic Monitoring: A Randomized Trial of Contamination with Sampling through Conventional Stopcocks versus a Novel Closed System. Infect Control Hosp Epidemiol 1989. [DOI: 10.2307/30144237] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|