1
|
Nicolucci A, Leonardi L. Compatibility of PiC Insupen Needles with a Broad Range of Pens for the Injection of Subcutaneously Administered Drugs for Diabetes. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2022; 15:71-77. [PMID: 35378795 PMCID: PMC8976478 DOI: 10.2147/mder.s352849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 03/14/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To test the compatibility of PiC Insupen needles with a broad range of pens produced by different manufacturers for the injection of subcutaneously administered drugs. Patients and Methods The “extreme” products in PiC pen needles range were considered (G33x4 mm and G29x12 mm), to verify that the compatibility was not affected by the cannula diameter and length. Following the launch of the G34x3.5mm needle, additional tests were performed comparing G33x4 and G34x3.5 pen needles. A test medium with viscosity similar to insulin was used. Additional tests were performed with a liquid with a much higher viscosity. All the requirements of the technical standard ISO 11608-2 were satisfied, and the differences between G29, G33 and G34 were negligible. Therefore, the PiC Insupen needle G33x4mm was chosen as representative of the PiC pen needles. Dose accuracy and needle hub torque were assessed, according to the ISO 11608-2:2012 norms. For pens with variable volume, two different volumes were tested (Vlow and Vhigh) in random order, testing 60 needles with Vlow and 60 with Vhigh. Results Overall, 50 different pens were tested. Dose accuracy acceptance criteria were met for all the pens tested, with the only exception of Vhigh for Berlipen Precision pen. The removal torque was adequate for all pens, with the only exception of Berlipen 301 and Berlipen 302 pens. Conclusion We documented that Pikdare needles are compatible with a large array of different pens for the injection of insulin and other drugs administered subcutaneously.
Collapse
Affiliation(s)
- Antonio Nicolucci
- Center for Outcomes Research and Clinical Epidemiology (CORESEARCH Srl), Pescara (PE), Italy
- Correspondence: Antonio Nicolucci, Center for Outcomes Research and Clinical Epidemiology (CORESEARCH Srl), Corso Umberto I, Pescara (PE), 103 – 65122, Italy, Tel +39 085 9047114, Fax +39 085 9047113, Email
| | | |
Collapse
|
2
|
De Berardis G, Scardapane M, Lucisano G, Abbruzzese S, Bossi AC, Cipponeri E, D'Angelo P, Fontana L, Lancione R, Marelli G, Sciangula L, Nicolucci A. Efficacy, safety and acceptability of the new pen needle 34G × 3.5 mm: a crossover randomized non-inferiority trial; AGO 02 study. Curr Med Res Opin 2018; 34:1699-1704. [PMID: 29924641 DOI: 10.1080/03007995.2018.1491396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
OBJECTIVE Insulin injection aspects, such as fear of injection and pain, directly affect glycemic control, patient adherence and quality of life. Use of thinner and shorter needles could increase acceptance of injections. The aim of the study is to evaluate the non-inferiority of the new 34G × 3.5 mm needle compared to a 32G × 4 mm in patients with diabetes treated with insulin. METHODS This is an open, randomized, two-period crossover, non-inferiority trial. Every treatment period lasted 3 weeks. Patients with type 1 or type 2 diabetes, treated with multiple daily insulin injections, were randomly assigned to receive a 34G × 3.5 mm or a 32G × 4 mm pen needle. The primary endpoint was the non-inferiority of the 34G × 3.5 mm in comparison with the 32G × 4 mm pen needle in terms of percentage absolute change of blood fructosamine (% |ΔFru|), using a non-inferiority margin of 20%. RESULTS Overall 77 patients were randomized and 73 completed the study. Patients characteristics were: 52% male, 80.5% affected by type 1 diabetes, mean age 52 years (±14.6), mean BMI 24.5 kg/m2 (±5.6), HbA1c 8% (±1.1) and baseline fructosamine level 350 µmol/l (±84). Mean fructosamine levels increased by 0.56 µmol/l with the 34G needle, while a reduction of 7.29 μmol/l was documented with the 32G needle. The difference between the two groups (7.84 μmol/l) was not statistically significant (p = .27). The % |ΔFru| between the two groups was 7.55% (95% CI 5.67-9.44), meeting the non-inferiority criterion. Glycemic variability, expressed as standard deviation of fasting blood glucose and post-prandial glucose, was not different between the two treatment groups (p = .63 and p = .77, respectively). CONCLUSIONS The 34G × 3.5 mm needle was non-inferior to the 32G × 4 mm needle regarding fructosamine levels and glycemic variability supporting the suitability of the 34G × 3.5 mm needle for insulin injection in patients with diabetes. CLINICAL TRIAL REGISTRATION NCT02690467.
Collapse
Affiliation(s)
- Giorgia De Berardis
- a Center for Outcomes Research and Clinical Epidemiology - CORESEARCH , Pescara , Italy
| | - Marco Scardapane
- a Center for Outcomes Research and Clinical Epidemiology - CORESEARCH , Pescara , Italy
| | - Giuseppe Lucisano
- a Center for Outcomes Research and Clinical Epidemiology - CORESEARCH , Pescara , Italy
| | | | | | | | | | | | | | | | | | - Antonio Nicolucci
- a Center for Outcomes Research and Clinical Epidemiology - CORESEARCH , Pescara , Italy
| |
Collapse
|
3
|
Tandon N, Kalra S, Balhara YPS, Baruah MP, Chadha M, Chandalia HB, Prasanna Kumar KM, Madhu SV, Mithal A, Sahay R, Shukla R, Sundaram A, Unnikrishnan AG, Saboo B, Gupta V, Chowdhury S, Kesavadev J, Wangnoo SK. Forum for Injection Technique and Therapy Expert Recommendations, India: The Indian Recommendations for Best Practice in Insulin Injection Technique, 2017. Indian J Endocrinol Metab 2017; 21:600-617. [PMID: 28670547 PMCID: PMC5477451 DOI: 10.4103/ijem.ijem_97_17] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Health-care professionals in India frequently manage injection or infusion therapies in persons with diabetes (PWD). Patients taking insulin should know the importance of proper needle size, correct injection process, complication avoidance, and all other aspects of injection technique from the first visit onward. To assist health-care practitioners in their clinical practice, Forum for Injection Technique and Therapy Expert Recommendations, India, has updated the practical advice and made it more comprehensive evidence-based best practice information. Adherence to these updated recommendations, learning, and translating them into clinical practice should lead to effective therapies, improved outcomes, and lower costs for PWD.
Collapse
Affiliation(s)
- Nikhil Tandon
- Department of Endocrinology, All India Institute of Medical Sciences, New Delhi, India
| | - Sanjay Kalra
- Department of Endocrinology, Bharti Hospital and BRIDE, Karnal, Haryana, India
| | - Yatan Pal Singh Balhara
- Department of Psychiatry, National Drug Dependence Treatment Centre, All India Institute of Medical Sciences, New Delhi, India
| | - Manash P. Baruah
- Department of Endocrinology, Excel Center (Unit of Excel Care Hospitals), Guwahati, Assam, India
| | - Manoj Chadha
- Department of Endocrinology, P.D. Hinduja National Hospital and Medical Research Centre, Mumbai, Maharashtra, India
| | - Hemraj B. Chandalia
- Department of Endocrinology, Diabetes Endocrinology Nutrition Management and Research Centre, Mumbai, Maharashtra, India
| | - K. M. Prasanna Kumar
- Department of Endocrinology and Metabolism, M S Ramaiah Medical College, CEO-Bangalore Diabetes Hospital, Bengaluru, Karnataka, India
| | - S. V. Madhu
- Department of Medicine, Division of Endocrinology and Metabolism, University College of Medical Sciences, New Delhi, India
| | - Ambrish Mithal
- Department of Endocrinology, Medanta Medicity, Gurugram, Haryana, India
| | - Rakesh Sahay
- Department of Endocrinology, Osmania Medical College, Osmania General Hospital, Hyderabad, Telangana, India
| | - Rishi Shukla
- Department of Endocrinology, Regency Hospital, Private Ltd. and Centre for Diabetes and Endocrinology, Kanpur, Uttar Pradesh, India
| | - Annamalai Sundaram
- Department of Endocrinology, Ambedkar Institute of Diabetes, Government Kilpauk Medical College, Chennai, Tamil Nadu, India
| | - Ambika G. Unnikrishnan
- Department of Clinical Diabetology and Endocrinology, Chellaram Diabetes Institute, Pune, Maharashtra, India
| | - Banshi Saboo
- Diabetologist and Endocrine and Metabolic Physician, Diacare-Diabetes Care and Hormone Clinic, Ahmedabad, Gujarat, India
| | | | - Subhankar Chowdhury
- Department of Endocrinology, IPGME & R and SSKM Hospital, Kolkata, West Bengal, India
| | - Jothydev Kesavadev
- Jothydev's Diabetes and Reserarch Center, Thiruvananthapuram, Kerala, India
| | - Subhash K. Wangnoo
- Apollo Centre for Obesity, Diabetes and Endocrinology, Indraprastha Apollo Hospital, New Delhi, India
| |
Collapse
|
4
|
Guo X, Wang W. Challenges and recent advances in the subcutaneous delivery of insulin. Expert Opin Drug Deliv 2016; 14:727-734. [PMID: 27626885 DOI: 10.1080/17425247.2016.1232247] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Xiaohui Guo
- Department of Endocrinology, Peking University First Hospital, Beijing, China
| | - Wei Wang
- Department of Endocrinology, Peking University First Hospital, Beijing, China
| |
Collapse
|