1
|
Ñaupari-Villasante R, Falconi-Páez C, Castro AS, Gutiérrez MF, Mendez-Bauer ML, Aliaga P, Dávila-Sánchez A, Arrais C, Reis A, Loguercio AD. Clinical performance of posterior restorations using a universal adhesive over moist and dry dentin: A 36-month double-blind split-mouth randomized clinical trial. J Dent 2024; 147:105080. [PMID: 38788919 DOI: 10.1016/j.jdent.2024.105080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/12/2024] [Accepted: 05/14/2024] [Indexed: 05/26/2024] Open
Abstract
OBJECTIVES To evaluate the influence of dentin moisture on the clinical behavior of a universal adhesive on posterior teeth after 36 months of follow-up. METHODS Forty-five patients participated in this study. Following a split-mouth design, three operators placed 90 Class I/Class II restorations over moist dentin (MD) or dry (DD) (n = 45) with resin composite (Filtek Bulk Fill) and a universal adhesive used in the etch-and-rinse mode (Single Bond Universal). Each restoration was evaluated according to the FDI and USPHS criteria (postoperative sensitivity, fracture and retention, marginal staining, marginal adaptation, and recurrence of caries) at baseline and after 6-, 12-, and 36 months. For statistical analysis, Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used. RESULTS No significant difference between groups was observed in each FDI criterion after 36 months of clinical evaluation (p > 0.05). The retention rates (confidence interval 95 %) were 97.37 % (86.5 - 99.5) for both MD and DD without significant difference between them (p > 0.05). Eight restorations (MD = 4; DD = 4) showed minimal marginal staining defects (p > 0.05). Two restorations were lost (MD = 1; DD = 1). Fifteen restorations (MD = 8; DD = 7) presented minor marginal discrepancies according to the FDI criteria (p > 0.05). CONCLUSION The clinical performance of the universal adhesive when applied in etch-and-rinse mode was not influenced by dentin moisture in posterior bulk-fill composite restorations. CLINICAL SIGNIFICANCE The level of dentin moisture appears not to influence the clinical efficacy of a universal adhesive when applied using the etch-and-rinse technique in posterior composite resin restorations.
Collapse
Affiliation(s)
- Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, 84030-900, Ponta Grossa, Brazil
| | - Camila Falconi-Páez
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, 84030-900, Ponta Grossa, Brazil
| | - Andrea S Castro
- Department of Restorative Dentistry, School of Dentistry, Tuiuti University of Parana ́, Curitiba, Brazil
| | - Mario F Gutiérrez
- Universidad de los Andes, Facultad de Odontología, Av. Monseñor Álvaro del Portillo 12455, 7550000, Las Condes, Santiago, Chile; University of Chile, Faculty of Dentistry, Institute for Research in Dental Sciences, Av. Olivos 943, 8380544, Independencia, Santiago, Chile
| | - Maria L Mendez-Bauer
- Research Department, School of Dentistry, University Francisco Marroquin, Guatemala City, Guatemala
| | - Paulina Aliaga
- Departamento de Odontología Restauradora y Materiales Dentales. Escuela de Odontología Universidad San Francisco de Quito, Av. Pampite y Diego Robles, 170901, Quito, Ecuador
| | - Andrés Dávila-Sánchez
- Departamento de Odontología Restauradora y Materiales Dentales. Escuela de Odontología Universidad San Francisco de Quito, Av. Pampite y Diego Robles, 170901, Quito, Ecuador
| | - Cesar Arrais
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, 84030-900, Ponta Grossa, Brazil
| | - A Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, 84030-900, Ponta Grossa, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, 84030-900, Ponta Grossa, Brazil.
| |
Collapse
|
2
|
Loguercio AD, Carpio-Salvatierra B, Ñaupari-Villasante R, Wendlinger M, Armas-Vega A, Cavagnaro S, León A, Aliaga-Galvez R, Gutiérrez MF. Clinical evaluation of a new chemically-cured bulk-fill composite in posterior restorations: 6-month multicenter double-blind randomized clinical trial. J Dent 2024; 149:105246. [PMID: 39025426 DOI: 10.1016/j.jdent.2024.105246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Revised: 07/12/2024] [Accepted: 07/15/2024] [Indexed: 07/20/2024] Open
Abstract
OBJECTIVE To evaluate the postoperative sensitivity (POS), as well as the clinical performance of posterior restorations using a new chemically-cured bulk-fill composite (Stela Automix and Stela Capsule, SDI) comparing with a light-cured bulk-fill composite after 6 months. METHODS Fifty-five participants with at least three posterior teeth needing restoration were recruited. A total of 165 restorations were performed on Class I or Class II cavities. After the application of Stela primer, the chemically-cured composite (Stela Automix or Stela Capsule) was inserted. For the light-cured composite group, a universal adhesive (Scotchbond Universal) was applied with a bulk-fill composite (Filtek One). Participants were evaluated for spontaneous and stimulated POS in the baseline, after 48 h, 7 days, and 6 months. Additionally, each restoration was assessed using the updated version of FDI criteria after 6 months. The differences in the proportions of the groups were compared by Cochran test statistics (α = 0.05). RESULTS Both chemically-cured composites showed a lower risk of POS compared to the light-cured composite at baseline and up to 48 h (p < 0.04). A significantly lower surface luster and texture was observed for the Stela Capsule composite compared to the light-cured bulk-fill composite (baseline and 6 months; p = 0.03). A significant color mismatch was observed for the light-cured bulk-fill composite compared to the chemically-cured composites (baseline and 6 months; p = 0.03). No significant differences were observed in any other item evaluations (p > 0.05). CONCLUSION Chemically-cured composites exhibit lower postoperative sensitivity and less color mismatch compared to a light-cured bulk-fill composite after 6 months of clinical service. CLINICAL SIGNIFICANCE The chemically-cured composites appear to be an appealing option for restoring posterior teeth, as they exhibit lower postoperative sensitivity compared to a light-cured bulk-fill composite, both at baseline and up to 48 h, and less color mismatch.
Collapse
Affiliation(s)
- Alessandro D Loguercio
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil; Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito 170147, Ecuador
| | - B Carpio-Salvatierra
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - R Ñaupari-Villasante
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - M Wendlinger
- State University of Ponta Grossa, School of Dentistry, Ponta Grossa/PR, 84030-000, Brazil
| | - Ana Armas-Vega
- Facultad de Ciencias de la Salud, Carrera de Odontologia, Universidad De Los Hemisferios, Quito 170147, Ecuador
| | - S Cavagnaro
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - A León
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - R Aliaga-Galvez
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile
| | - M F Gutiérrez
- Universidad de los Andes, Chile, Facultad de Odontología, Santiago 7550000, Chile.
| |
Collapse
|
3
|
Torres CRG, Mailart MC, Moecke SE, Matuda AGN, Veloso SM, da Silva Ávila DM, Nicoló RD, Borges AB. Flowable bulk-fill versus layering restorative material on Class II restorations: A randomized clinical trial. J Dent 2024; 148:105154. [PMID: 38942111 DOI: 10.1016/j.jdent.2024.105154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 06/20/2024] [Accepted: 06/22/2024] [Indexed: 06/30/2024] Open
Abstract
OBJECTIVE This study evaluated the clinical performance of Class II restorations made with flowable bulk-fill base versus conventional layering ORMOCER-based restorative material in a split-mouth randomized clinical trial. METHODS Thirty patients received two class II restorations (n = 60) performed with different strategies. All preparations received the application of the universal self-etching adhesive system according to the manufacturer's recommendation, followed by the placement of a sectional matrix, wooden wedge, and separation ring. The first restoration was performed using 4 mm of flowable bulk-fill material covered by 2 mm of conventional viscosity restorative material (Bulk-fill technique). The second restoration was performed only with the conventional viscosity material, with a maximum of 2 mm thick increments, up to fill the cavity (Layering technique). After occlusal adjustment, the same polishing system was used for all restorations. Evaluations using the FDI criteria were conducted after 7 days, 12, and 24 months. Data were analyzed with the Fisher's Exact test (α=0.05). RESULTS From 30 participants, 24 attended the 24-month recall, and 48 restorations were evaluated. All restorations received acceptable overall scores for esthetic and biological properties after this period, while only 6.66 % of the restorations exhibited unacceptable overall scores for the functional properties in both groups. No significant differences between the tested restorative materials and techniques were found for each FDI criterion assessed. The success rate after 2 years was 93.33 % for both groups. CONCLUSION Both restorative materials exhibited good clinical performance for the parameters analyzed with no differences between them after 24-month follow-up. CLINICAL RELEVANCE Flowable bulk-fill ORMOCER-based material is a suitable alternative for direct Class II restorations, providing good clinical outcomes and simplifying the restorative procedure. CLINICAL TRIAL REGISTRATION NUMBER RBR-6mvp9w.
Collapse
Affiliation(s)
- Carlos Rocha Gomes Torres
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil.
| | - Mariane Cintra Mailart
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Sabrina Elise Moecke
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Amanda Guedes Nogueira Matuda
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Sheyla Mamede Veloso
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Daniele Mara da Silva Ávila
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Rebeca Di Nicoló
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| | - Alessandra Bühler Borges
- Department of Restorative Dentistry, Institute of Science and Technology, Sao Paulo State University - UNESP, Brazil. Av. Engenheiro Francisco Jose Longo, 777, Jardim Sao Dimas, Sao Jose dos Campos, SP, CEP 12245-000, Brazil
| |
Collapse
|
4
|
Elkady M, Abdelhakim SH, Riad M. Impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity; a randomized controlled clinical trial. BMC Oral Health 2024; 24:453. [PMID: 38622629 PMCID: PMC11017642 DOI: 10.1186/s12903-024-04170-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 03/20/2024] [Indexed: 04/17/2024] Open
Abstract
BACKGROUND This clinical study was conducted aiming to evaluate the impact of repeated preheating of bulk-fill resin composite on postoperative hypersensitivity. METHODS A total of 105 eligible, consenting adults were recruited. Patients had posterior teeth suffering from proximal decay with no signs of irreversible pulpitis. Patients were prepared for Class II restorations and restored with bulk-fill resin composite. Patients were randomized into three groups of 35 patients according to the number of preheating cycles for the resin composite syringe used; group I: no preheating; control group at room temperature, group II: Resin composite preheated once, and group III: Resin composite preheated ten cycles. Patients were assessed for postoperative dentin hypersensitivity using the visual analogue scale (VAS) at three-time intervals: day one, one week and by the end of one month after restorative treatment. Statistical analysis was performed; ANOVA with a single factor was used to test for significance at a p value ≤ 0.05. For nonparametric data, the Kruskal‒Wallis test was used to compare the three testing groups. Friedman's test was used to study the changes within each group. Dunn's test was used for pairwise comparisons when the Kruskal‒Wallis test or Friedman's test was significant. RESULTS The scores of the three groups through the three time intervals were almost zero except for the first day where VAS scores were recorded with maximum score of 3 for groups I and II. Groups II and III; there was no statistically significant change in hypersensitivity scores by time with P-values 0.135 and 0.368, respectively. However, for group I there was a significant difference from VAS score recorded on first day and the two following time intervals. CONCLUSION The repeated preheating cycles of bulk-fill resin composite prior to curing had no adverse effect on the patients regarding postoperative dentin hypersensitivity. This information could be of utmost significance, as the same resin composite syringe can undergo numerous preheating cycles clinically before it is completely consumed with the advantage of improvement on the handling properties. TRIAL REGISTRATION The protocol of the current study was registered at www. CLINICALTRIALS gov , with the identification number NCT05289479 on 21/03/2022. All procedures involving human participants were performed in accordance with the ethical standards of the Research Ethics Committee of the Faculty of Dentistry, Minia University, Egypt, under the approval number 73/440 on 11/09/2020.
Collapse
Affiliation(s)
- Mahmoud Elkady
- Conservative Dentistry Department, Faculty of Dentistry, Assiut University, Assiut, Egypt
| | | | - Mona Riad
- Conservative Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, Egypt.
| |
Collapse
|
5
|
González CC, Ñaupari-Villasante R, Dos Santos de Castro A, Mendez-Bauer L, Dávila-Sanchez A, Aliaga-Sancho P, Gutierrez MF, Reis A, Loguercio AD. Clinical evaluation of posterior restorations over wet and dry dentin using an etch-and-rinse adhesive: A 36-month randomized clinical trial. Dent Mater 2024; 40:619-628. [PMID: 38369403 DOI: 10.1016/j.dental.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/30/2024] [Accepted: 02/12/2024] [Indexed: 02/20/2024]
Abstract
OBJECTIVES To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. METHODS Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. RESULTS After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). SIGNIFICANCE The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.
Collapse
Affiliation(s)
- Claudia C González
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta, Ponta Grossa, PR, Brazil
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta, Ponta Grossa, PR, Brazil
| | | | - Luján Mendez-Bauer
- Research Department, Faculty of Dentistry, Francisco Marroquím University, Guatemala city, Guatemala
| | - Andrés Dávila-Sanchez
- Universidad San Francisco de Quito USFQ, Department of Restorative Dentistry and Dental Materials, School of Dentistry, Quito, Ecuador
| | - Paulina Aliaga-Sancho
- Universidad San Francisco de Quito USFQ, Department of Restorative Dentistry and Dental Materials, School of Dentistry, Quito, Ecuador
| | - Mario Felipe Gutierrez
- Universidad de los Andes, Facultad de Odontología, Santiago, Chile; University of Chile, Institute for Research in Dental Sciences, Faculty of Dentistry, Santiago, Chile
| | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta, Ponta Grossa, PR, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta, Ponta Grossa, PR, Brazil.
| |
Collapse
|
6
|
Thyvalikakath T, Siddiqui ZA, Eckert G, LaPradd M, Duncan WD, Gordan VV, Rindal DB, Jurkovich M, Gilbert GH. Survival analysis of posterior composite restorations in National Dental PBRN general dentistry practices. J Dent 2024; 141:104831. [PMID: 38190879 PMCID: PMC10866618 DOI: 10.1016/j.jdent.2024.104831] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/01/2024] [Accepted: 01/02/2024] [Indexed: 01/10/2024] Open
Abstract
OBJECTIVE Quantify the survival of posterior composite restorations (PCR) placed during the study period in permanent teeth in United States (US) general dental community practices and factors predictive of that survival. METHODS A retrospective cohort study was conducted utilizing de-identified electronic dental record (EDR) data of patients who received a PCR in 99 general dentistry practices in the National Dental Practice-Based Research Network (Network). The final analyzed data set included 700,885 PCRs from 200,988 patients. Descriptive statistics and Kaplan Meier (product limit) estimator were performed to estimate the survival rate (defined as the PCR not receiving any subsequent treatment) after the first PCR was observed in the EDR during the study time. The Cox proportional hazards model was done to account for patient- and tooth-specific covariates. RESULTS The overall median survival time was 13.3 years. The annual failure rates were 4.5-5.8 % for years 1-5; 5.3-5.7 %, 4.9-5.5 %, and 3.3-5.2 % for years 6-10, 11-15, and 16-20, respectively. The failure descriptions recorded for < 7 % failures were mostly caries (54 %) and broken or fractured tooth/restorations (23 %). The following variables significantly predicted PCR survival: number of surfaces that comprised the PCR; having at least one interproximal surface; tooth type; type of prior treatment received on the tooth; Network region; patient age and sex. Based on the magnitude of the multivariable estimates, no single factor predominated. CONCLUSIONS This study of Network practices geographically distributed across the US observed PCR survival rates and predictive factors comparable to studies done in academic settings and outside the US. CLINICAL SIGNIFICANCE Specific baseline factors significantly predict the survival of PCRs done in US community dental practices.
Collapse
Affiliation(s)
- Thankam Thyvalikakath
- Office of Dental Informatics & Digital Health, Indiana University School of Dentistry, IUPUI, Research Scientist & Director, Dental Informatics, Center for Biomedical Informatics, Regenstrief Institute, Inc., OH 144A, 415 Lansing Street, Indianapolis, IN 46202, USA.
| | - Zasim Azhar Siddiqui
- West Virginia University School of Pharmacy, Morgantown, WV, USA; Department of Public Health and Dental Informatics, Indiana University School of Dentistry, IUPUI, Indianapolis, IN 46202, USA
| | - George Eckert
- Department of Biostatistics and Health Data Science, Indiana University School of Medicine, 340W 10th St, Indianapolis, IN 46202, USA
| | - Michelle LaPradd
- Department of Biostatistics and Health Data Science, Indiana University School of Medicine, 340W 10th St, Indianapolis, IN 46202, USA; Syneos Health, 1030 Sync St, Morrisville, NC 27560, USA
| | - William D Duncan
- Department of Community Dentistry, University of Florida, College of Dentistry, Gainesville, FL, USA; Biomedical Data Science and Shared Resource, Roswell Park Cancer Center, Buffalo, NY, USA
| | - Valeria V Gordan
- University of Florida, College of Dentistry, Gainesville, FL, USA
| | - D Brad Rindal
- 8170 33rd Avenue South | P.O. Box 1524, MS 23301A Minneapolis MN 55440, USA
| | - Mark Jurkovich
- HealthPartners Institute, Minneapolis MN, USA; 8170 33rd Ave S, Bloomington, MN 55440, USA
| | - Gregg H Gilbert
- Department of Clinical and Community Sciences, School of Dentistry, SDB Room 109, University of Alabama at Birmingham, Birmingham, AL, USA; National Dental PBRN Collaborative Group, 1720 University Blvd, Birmingham, AL 35294, USA; University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
7
|
Loguercio AD, Ñaupari-Villasante R, Gutierrez MF, Gonzalez MI, Reis A, Heintze SD. 5-year clinical performance of posterior bulk-filled resin composite restorations: A double-blind randomized controlled trial. Dent Mater 2023; 39:1159-1168. [PMID: 37839995 DOI: 10.1016/j.dental.2023.10.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/07/2023] [Accepted: 10/08/2023] [Indexed: 10/17/2023]
Abstract
OBJECTIVES The aim of this double-blind, and randomized controlled clinical trial was to evaluate the 5-year clinical performance of posterior resin composite restorations placed with the incremental filling technique [IF] or the bulk-fill technique [BF]. Two different adhesive systems were used: etch-&-rinse (ER) or self-etch (SE). METHODS Posterior dental teeth of 72 participants (n = 236), with a cavity depth of at least 3 mm, were randomly divided into four groups. Restorations were applied with either Tetric N-Bond or Tetric N-Bond SE. The composite resin Tetric N-Ceram Bulk-Fill was placed either with IF or BF. Restorations were evaluated using FDI criteria at baseline and after 1, 2, 3, 4, and 5 years. Statistical analysis was performed using the Wilcoxon Signed rank test (a=0.05). RESULTS Two hundred and four restorations were evaluated after 5 years. Eleven restorations were considered 'failed', ten due to fracture (4 IF and 6 BF) and one due to secondary caries (IF). The annual failure rate was 1.2% for BF and 1% for IF (p = 0.35). When comparing BF and IF, no significant differences were found for any of the parameters evaluated (p > 0.05). Regarding the adhesive systems, 44 and 51 restorations showed minor problems in terms of marginal adaptation and staining, with significantly more marginal discoloration when the self-etch adhesive was used (p = 0.002). SIGNIFICANCE The bulk-fill restorative technique showed good clinical behavior compared to the incremental filling technique, especially when using an etch-&-rinse adhesive, after 5 years of clinical evaluation.
Collapse
Affiliation(s)
- Alessandro D Loguercio
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Romina Ñaupari-Villasante
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | - Mario F Gutierrez
- Universidad de los Andes, Chile, Facultad de Odontologia, Chile; University of Chile, Department of Restorative Dentistry, Faculty of Dentistry, Chile
| | | | - Alessandra Reis
- Department of Restorative Dentistry, School of Dentistry, Ponta Grossa State University, Ponta Grossa, PR, Brazil
| | | |
Collapse
|
8
|
Hanzen TA, de Paula AM, Grokoski E, de Oliveira ILM, Arana-Gordillo LA, de Melo Monteiro GQ, Perdigão J, Loguercio AD. Glutaraldehyde-based desensitizer does not influence postoperative sensitivity and clinical performance of posterior restorations: A 24-month randomized clinical trial. Dent Mater 2023; 39:946-956. [PMID: 37648563 DOI: 10.1016/j.dental.2023.08.179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVES To evaluate the influence of a glutaraldehyde-based desensitizer (GL) on postoperative sensitivity (POS) in posterior bulk-fill resin composite restorations using an adhesive applied in the self-etch (SE) and etch-and-rinse (ER) strategies; and to assess the clinical performance of the restorations. METHODS Posterior resin composite restorations (n = 228) at least 3 mm deep were inserted in 57 subjects using a split-mouth design. The adhesive was applied with/without prior application of a GL. A resin composite was used for all restorations. Spontaneous POS (risk and intensity), as well as POS caused by stimulation with an air blast and assess the response to horizontal and vertical percussion was assessed using two scales in the baseline and after 7, 14, and 30 days. In addition, some parameters were evaluated using FDI criteria up to 24 months of clinical service. RESULTS No significant POS was observed (p > 0.05). A higher absolute risk and intensity of spontaneous POS was observed within 7 days (35.1%), without statistically significant differences among groups. At 24 months 5 restorations were considered clinically unsatisfactory, and 73 restorations showed minor discrepancies in adaptation, with no significant differences between groups (p > 0.05). SIGNIFICANCE A GL agent does not influence POS in posterior restorations with bulk-fill resin composite. It may be considered a dispensable clinical step in the restorative protocol.
Collapse
Affiliation(s)
| | | | - Eduardo Grokoski
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| | | | | | | | - Jorge Perdigão
- University of Minnesota, Division of Operative Dentistry, Department of Restorative Sciences, Minneapolis, MN, USA.
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Ponta Grossa, Brazil
| |
Collapse
|
9
|
Sengupta A, Naka O, Mehta SB, Banerji S. The clinical performance of bulk-fill versus the incremental layered application of direct resin composite restorations: a systematic review. Evid Based Dent 2023; 24:143. [PMID: 37402908 PMCID: PMC10516750 DOI: 10.1038/s41432-023-00905-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 06/09/2023] [Indexed: 07/06/2023]
Abstract
OBJECTIVES To systematically review the scientific evidence comparing the clinical effectiveness of bulk-fill versus incrementally layered conventional resin composites and to evaluate if one method offers clear merits with specific clinical outcomes. MATERIALS AND METHODS Using relevant mesh terms and pre-established eligibility criteria in PubMed, Embase, Scopus and Web of Science, a thorough scientific search was conducted with an end-date of 30.04.2023. Randomized controlled clinical trials that involved the direct comparison of Class I and Class II resin composite restorations applied using incremental layering techniques versus bulk-filled in permanent teeth with an observation period of at least six months were considered. To evaluate the bias risk of the finalized records, a revised version of the Cochrane risk-of-bias tool for randomized trials was implemented. RESULTS Out of the 1445 records determined, 18 eligible reports were chosen for qualitative analysis. Data obtained was categorized as per, the cavity design, the intervention, the comparator(s), the methods of success/failure assessment, the outcomes, and follow-up. Two studies demonstrated an overall low-risk of bias, fourteen studies raised some concerns, and two studies exhibited high-risk. CONCLUSION Bulk filled resin composite restorations demonstrated clinical outcomes similar to those of incrementally layered resin composite restorations within a review interval of 6 months to 10 years.
Collapse
Affiliation(s)
- Arjita Sengupta
- Faculty of Dentistry Oral and Craniofacial Sciences, King's College London, London, UK
| | - Olga Naka
- Faculty of Dentistry Oral and Craniofacial Sciences, King's College London, London, UK.
- School of Dentistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
| | - Shamir B Mehta
- Faculty of Dentistry Oral and Craniofacial Sciences, King's College London, London, UK
| | - Subir Banerji
- Faculty of Dentistry Oral and Craniofacial Sciences, King's College London, London, UK
| |
Collapse
|
10
|
Zahran M, Abo El-Farag S, Soltan H, Attia A. Fracture load of ultrathin occlusal veneers: Effect of thickness and surface conditioning. J Mech Behav Biomed Mater 2023; 145:106030. [PMID: 37473575 DOI: 10.1016/j.jmbbm.2023.106030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/12/2023] [Accepted: 07/15/2023] [Indexed: 07/22/2023]
Abstract
OBJECTIVE This in-vitro study is planned to analyze the effect of different thicknesses of ceramic occlusal veneers and different surface treatments on fracture resistance. MATERIALS AND METHODS A total of 48 sound mandibular molars are anatomically prepared from the occlusal surface with two different thicknesses (1.0 and 0.5 mm). CAD/CAM zirconia-reinforced glass ceramic blocks (Vita Suprinity) are used for fabricating occlusal veneers. The teeth are randomly divided into two primary groups A and B (n=24) according to occlusal veneer thickness. Each group is subdivided according to surface conditioning into three equal subgroups (n=8)-subgroup HF: etching with hydrofluoric acid and ceramic primer application; subgroup APF: etching with acidulated phosphate fluoride and ceramic primer application; subgroup EP: conditioning with etch and prime only. Dual-cure adhesive resin cement (Multilink Automix) is utilized to adhesively bond the veneers. All specimens are subjected to 240,000 cycles of dynamic load aging prior to the fracture resistance test. The fracture resistance is measured in Newton (N). The Failure mode patterns are analyzed and categorized using a scanning electron microscope (SEM). The results are analyzed using a two-way ANOVA with Bonferroni's Post-Hoc test, followed by a one-way ANOVA for each factor. That is in addition to one-way ANOVA for surface treatment under each thickness, each followed by Bonferroni's Post-Hoc test. Then, a T-test is used to compare the two thicknesses under each surface treatment. All tests are set at 0.05 significance level. RESULTS The two-way ANOVA test revealed that restoration thickness and surface treatment both significantly affect the fracture resistance values (p<0.05). The highest fracture resistance mean (2672±216N) is obtained from HF at 1.0 mm thickness, while the lowest mean (2104±299N) is obtained from APF at 0.5 mm thickness. CONCLUSION All test groups, regardless of thickness, demonstrated fracture resistance values that exceeded both normal and parafunctional bite forces. The veneers that bonded after hydrofluoric acid etching followed by ceramic primer application showed more favourable fracture patterns.
Collapse
Affiliation(s)
- Maged Zahran
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Shaimaa Abo El-Farag
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Hassan Soltan
- Production and Mechanical Design Engineering Department, Faculty of Engineering, Mansoura University, Mansoura 35516, Egypt.
| | - Ahmed Attia
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| |
Collapse
|
11
|
Park EH, Na YK, Gug H, Lee DS, Park JC, Park SH, Shon WJ. Development of a new universal adhesive containing CPNE7-derived peptide and its potential role in reducing postoperative sensitivity. Dent Mater J 2023:2022-181. [PMID: 37271544 DOI: 10.4012/dmj.2022-181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Post-operative sensitivity (POS) is the most common clinical dental complaint after tooth preparation and resin-based composite restoration. In our previous study, copine 7 (CPNE7) and CPNE7-derived peptide (CPNE7-DP) induced in vitro odontoblast differentiation and in vivo dentin formation. Here, we incorporated CPNE7-DP into All-Bond Universal (ABU) adhesive, developing ABU/CPNE7-DP. This study aimed to investigate the possibility of reducing POS using ABU/CPNE7-DP. We first determined the stability of CPNE7-DP under low pH. Furthermore, we evaluated its dentinal tubule penetration, in vitro odontogenic differentiation potential, in vivo tertiary dentin formation and its effects on bonding performance. CPNE7-DP was stable at pH 1.2, even lower than ABU's pH of 3.2. ABU/CPNE7-DP can penetrate dentinal tubules, stimulate odontoblast differentiation in vitro and generate tertiary dentin with tubular structure in vivo without interfering with bonding performance. Therefore, ABU/CPNE7-DP may serve as a novel bioactive adhesive for reducing POS.
Collapse
Affiliation(s)
- Eun Hyun Park
- Department of Conservative Dentistry, Dental Research Institute, School of Dentistry, Seoul National University
| | - Yun Kyung Na
- Department of Conservative Dentistry, Dental Research Institute, School of Dentistry, Seoul National University
| | - Hyeri Gug
- Laboratory for The Study of Regenerative Dental Medicine, Department of Oral Histology-Developmental Biology, School of Dentistry and Dental Research Institute, BK 21, Seoul National University
| | - Dong-Seol Lee
- Regenerative Dental Medicine R and D Center, HysensBio Co., Ltd
| | - Joo-Cheol Park
- Laboratory for The Study of Regenerative Dental Medicine, Department of Oral Histology-Developmental Biology, School of Dentistry and Dental Research Institute, BK 21, Seoul National University
| | - So-Hyun Park
- Department of Conservative Dentistry, Dental Research Institute, School of Dentistry, Seoul National University
| | - Won-Jun Shon
- Department of Conservative Dentistry, Dental Research Institute, School of Dentistry, Seoul National University
| |
Collapse
|
12
|
The influence of different placement techniques on the clinical success of bulk-fill resin composites placed in Class II cavities: a 4-year randomized controlled clinical study. Clin Oral Investig 2023; 27:541-557. [PMID: 36222961 DOI: 10.1007/s00784-022-04749-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2022] [Accepted: 10/02/2022] [Indexed: 02/03/2023]
Abstract
OBJECTIVE The purpose of this double-blind and split-mouth randomized controlled clinical trial was to evaluate the clinical success of the placement technique (bulk-filling and incremental techniques) of a bulk-fill resin composite in Class II carious lesions. MATERIALS AND METHODS Two different bulk-fill resin composites, X-tra fil (Voco) and Filtek Bulk Fill (3M ESPE), were used in the bulk-filling and incremental techniques for 20 patients. The study was carried out in 4 groups, with 20 restorations in each group. Restorations were appraised at baseline, 6-month, 2-year, and 4-year recall. World Dental Federation (FDI) and the US Public Health Service (USPHS) criteria were used in the evaluations. The Friedman, Kruskal-Wallis, and Mann-Whitney U tests were used for the statistical analysis. RESULTS At the end of year 4, there was no loss of restoration in any group. According to the USPHS and FDI criteria, there was a difference in the baseline and 4-year in marginal adaptation and marginal discoloration of the restorations (P < 0.05). When Filtek-Bulk was placed as an incremental technique, there was a minor fracture in four restorations (P > 0.05). In addition, Filtek-Bulk showed a color change according to the results based on both the USPHS and FDI criteria (P < 0.05). The difference between the two placement techniques of each resin composite was not significant at the year 4 recall when all criteria were evaluated (P ˃ 0.05). CONCLUSIONS The 4-year clinical success of the evaluated bulk-fill composites is not dependent on the placement technique used. CLINICAL RELEVANCE This study can help clinicians choose which technique (bulk fill and incremental techniques) bulk-fill composites can be used. TRIAL REGISTRATION US National Library of Medicine, www. CLINICALTRIALS gov , ID: NCT04565860 Registered on 10/09/2020. Clinical Evaluation of Bulk-fill resin Composites in Class II Restorations.
Collapse
|
13
|
Rai AV, Naik BD. Evaluation of remineralizing effect of zinc-carbonate hydroxyapatite on the reduction of postrestorative sensitivity: A randomized controlled clinical trial. J Conserv Dent 2023; 26:56-66. [PMID: 36908720 PMCID: PMC10003283 DOI: 10.4103/jcd.jcd_300_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 08/31/2022] [Accepted: 09/09/2022] [Indexed: 12/12/2022] Open
Abstract
Background The adhesive bonding ability of composite resins makes it unnecessary to remove tooth structure for retention, prevention, and convenience. However, postoperative sensitivity after placing composite restoration has been a significant problem experienced by clinicians. Aim The present randomized controlled trial was conducted to assess the role of dentin remineralization in the reduction of postoperative sensitivity after composite placement. Materials and Methods Eighty participants with occlusal carious teeth were randomly allocated to one of the four study groups, each having 20 participants, and are as follows: Group A with test group, Group A with control group, Group B with test group, and Group B with control group. Postoperative sensitivity was assessed using the Visual Analog Scale (VAS) and the United States Public Health Service (USPHS) criteria at different time intervals such as baseline, 1 week, 1 month, and 3 months. Data were analyzed using the Kruskal-Wallis ANOVA test, Mann-Whitney U-test, and Wilcoxon matched-pair test. Results All 80 participants were analyzed at the baseline, 1 week, 1 month, and the end of 3 months for the postoperative sensitivity using the VAS score and USPHS criteria. One restoration in Group A with control group reported mild sensitivity at the end of 1 week and one restoration in Group B with control group reported severe sensitivity at the end of 3 months, necessitating its replacement followed by root canal treatment. No relationship was reported between postoperative sensitivity and tooth type. There was no statistically significant difference in postoperative sensitivity in any of the treatment modalities. Conclusion Class I restoration using self-etch or selective-etch as well as with or without zinc-carbonate hydroxyapatite is a viable and predictable solution for the reduction of postoperative sensitivity if all the aspects of restorative techniques are considered precisely.
Collapse
Affiliation(s)
- Amulya Vittal Rai
- Department of Conservative Dentistry and Endodontics, SDM College of Dental Sciences and Hospital, Dharwad, Karnataka, India
| | - Balaram Damodar Naik
- Department of Conservative Dentistry and Endodontics, SDM College of Dental Sciences and Hospital, Dharwad, Karnataka, India
| |
Collapse
|
14
|
Castro AS, Maran BM, Gutierrez MF, Chemin K, Mendez-Bauer ML, Bermúdez JP, Reis A, Loguercio AD. Effect of Dentin Moisture in Posterior Restorations Performed with Universal Adhesive: A Randomized Clinical Trial. Oper Dent 2022; 47:E91-E105. [PMID: 35405005 DOI: 10.2341/20-215-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This double-blind, randomized clinical trial evaluated the influence of dentin moisture on postoperative sensitivity (POS), as well as, on clinical performance in posterior bulk-fill composite restorations, using a universal adhesive, until 12 months after clinical service. METHODS AND MATERIALS In accordance with a split-mouth design, 45 patients received posterior restorations, restored with a bulk-fill resin composite (Filtek Bulk Fill, 3M Oral Care) and a universal adhesive used in etch-and-rinse mode (SBU; Single Bond Universal Adhesive), which were applied on dry or moist dentin, with a cavity depth of at least 3 mm. Three operators placed 90 Class I/Class II restorations. Patients were evaluated for spontaneous and stimulated POS in the baseline, and after 48 hours, 7 days, and at 6 and 12 months. In addition, secondary parameters (marginal discoloration, marginal adaptation, fracture, and recurrent caries) were evaluated by World Dental Federation (FDI) criteria after 7 days and at 6 and 12 months. Statistical analyzes were performed using the Chi-square, Fisher exact, Friedman, Kruskall-Wallis, and Mann-Whitney tests (α=0.05). RESULTS No significant spontaneous and stimulated POS was observed when SBU was applied in dry and moist dentin (p>0.05). A significant and higher risk of spontaneous POS (20.0%; 95%CI 10.9-33.82 for dry dentin and 22.22%; 95%CI 12.54-36.27 for moist dentin) occurred up to 48 hours after restoration placement for the dry and moist dentin groups (p<0.02). However, the POS intensity was mild up to 48 hours with no significant difference between dry and moist dentin groups (p>0.79). When secondary parameters were evaluated, no significant differences between the groups were observed. CONCLUSION Dentin moisture did not influence POS in posterior bulk-fill composite restorations when associated with a universal adhesive applied in etch-and-rinse mode.
Collapse
Affiliation(s)
- A S Castro
- Andrea S Castro, DDS, MS, assistante professor, School of Dentistry, Tuiuti University, Curitiba, PR, Brazil
| | - B M Maran
- Bianca M Maran, DDS, MS, PhD, Department of Restorative Dentistry, School of Dentistry, State University of Western Paraná, Cascavel, PR, Brazil
| | - M F Gutierrez
- Mario F Gutierrez, DDS, MS, PhD, assistant professor, University de los Andes, Chile; assistant professor, Institute for Research in Dental Sciences, Faculty of Dentistry, University of Chile, Santiago, Chile
| | - K Chemin
- Kaprice Chemin, DDS, MS, PhD, assistant professor, School of Dentistry, Department of Health Sciences, School Unicesumar, Ponta Grossa, PR, Brazil
| | - M L Mendez-Bauer
- Maria L Mendez-Bauer, DDS, MSc, PhD, associate professor, Research Department, School of Dentistry, University Francisco Marroquin, Guatemala City, Guatemala
| | - J P Bermúdez
- Jorge P Bermúdez, DDS, MS, PhD student, Department of Prosthodontics, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, PR, Brazil
| | - A Reis
- Alessandra Reis, DDS, PhD, associate professor, Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, PR, Brazil
| | - A D Loguercio
- *Alessandro D Loguercio, DDS, MS, PhD, associate professor, Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Ponta Grossa, PR, Brazil
| |
Collapse
|
15
|
Is the clinical performance of composite resin restorations in posterior teeth similar if restored with incremental or bulk-filling techniques? A systematic review and meta-analysis. Clin Oral Investig 2022; 26:2281-2297. [DOI: 10.1007/s00784-021-04337-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 12/04/2021] [Indexed: 11/26/2022]
|
16
|
de Oliveira ILM, Hanzen TA, de Paula AM, Perdigão J, Montes MAJR, Loguercio AD, Monteiro GQDM. Postoperative sensitivity in posterior resin composite restorations with prior application of a glutaraldehyde-based desensitizing solution: A randomized clinical trial. J Dent 2021; 117:103918. [PMID: 34879245 DOI: 10.1016/j.jdent.2021.103918] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 11/28/2021] [Accepted: 12/03/2021] [Indexed: 11/25/2022] Open
Abstract
OBJECTIVES To evaluate the effect of a glutaraldehyde-based desensitizer on the postoperative sensitivity (POS) in posterior resin composite restorations up to 12 months using a universal adhesive (Tetric N-Bond Universal) with selective enamel etching (SE) or an etch-and-rinse (ER) strategy. METHODS Class I and class II resin composite restorations (n = 220) at least 3 mm deep were inserted in 55 subjects. The universal adhesive was applied using the SE (self-etch strategy on dentin with selective enamel etching) or the ER strategy, with or without prior application of a glutaraldehyde-based desensitizer (Gluma Desensitizer - GL) to form groups SEGL and ERGL. A bulk-fill resin composite (Tetric NCeram Bulk Fill) was used for all restorations. Spontaneous POS was assessed 7 days after the restorative procedure using the Visual Analog Scale (VAS) and the Numeric Rating Scale (NRS). After 7, 14, and 30 days of completing each restoration, the subjects were reassessed to evaluate POS caused by stimulation with an air blast, horizontal and vertical percussion. In addition, marginal discoloration, marginal adaptation, fracture, and recurrence of caries were evaluated using the FDI (World Dental Federation) criteria after 7 days and at 12 months. RESULTS No significant spontaneous or stimuli-induced POS was observed when restorations with or without GL were compared (p>0.05). A higher risk of spontaneous POS was observed within 7 days (40.0%; 95% CI 28.1 to 53.1), without statistically significant differences among groups. None of the participants reported POS at 12 months, however five restorations were considered clinically unsatisfactory (p > 0.05). CONCLUSIONS The previous application of GL did not significantly reduce spontaneous or stimuli-induced POS in posterior resin composite restorations at any time, regardless of the adhesive strategy used. CLINICAL SIGNIFICANCE The use of a glutaraldehyde-based desensitizing agent did not generate lower incidence of postoperative sensitivity in resin composite posterior restorations.
Collapse
Affiliation(s)
- Isabelle Lins Macêdo de Oliveira
- Dental School, Universidade de Pernambuco, Pernambuco, PE, Brazil; Instituto de Tecnologia de Pernambuco - ITEP/ Block B 1st floor. Av. Prof. Luis Freire, 700 - Cidade Universitária, Recife-PE, Brazil 50740-540
| | - Taíse Alessandra Hanzen
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Campus Uvaranas - Bloco M - 52B 2° Piso, General Carlos Cavalcanti Avenue, 4748 - Ponta Grossa - PR, 84030-900, Brazil
| | - Alexandra Mara de Paula
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Campus Uvaranas - Bloco M - 52B 2° Piso, General Carlos Cavalcanti Avenue, 4748 - Ponta Grossa - PR, 84030-900, Brazil
| | - Jorge Perdigão
- Universidade Católica Portuguesa, Centre for Interdisciplinary Research in Health, Faculty of Dental Medicine, Estrada da Circunvalação, 3504-505 Viseu, Portugal; Department of Restorative Sciences, School of Dentistry, University of Minnesota, 515 Delaware St. SE, 8-450 Moos Tower, Minneapolis, MN, 55455, United States.
| | - Marcos Antonio Japiassú Resende Montes
- Dental School, Universidade de Pernambuco, Pernambuco, PE, Brazil; Instituto de Tecnologia de Pernambuco - ITEP/ Block B 1st floor. Av. Prof. Luis Freire, 700 - Cidade Universitária, Recife-PE, Brazil 50740-540
| | - Alessandro Dourado Loguercio
- Department of Restorative Dentistry, School of Dentistry, State University of Ponta Grossa, Campus Uvaranas - Bloco M - 52B 2° Piso, General Carlos Cavalcanti Avenue, 4748 - Ponta Grossa - PR, 84030-900, Brazil
| | - Gabriela Queiroz de Melo Monteiro
- Dental School, Universidade de Pernambuco, Pernambuco, PE, Brazil; Instituto de Tecnologia de Pernambuco - ITEP/ Block B 1st floor. Av. Prof. Luis Freire, 700 - Cidade Universitária, Recife-PE, Brazil 50740-540
| |
Collapse
|
17
|
Rezende M, Martins ACR, da Silva JA, Reis A, de Geus JL. Compliance of randomized controlled trials in posterior restorations with the CONSORT statement: a systematic review of methodology. Clin Oral Investig 2021; 26:41-64. [PMID: 34595606 DOI: 10.1007/s00784-021-04198-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 09/21/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study aims to investigate the compliance of randomized controlled trials (RCTs) in posterior restorations with the Consolidated Standards of Reporting Trials Statement (CONSORT) statement and to analyze the risk of bias (RoB) of these studies. METHODS A systematic search was performed in PubMed, Scopus, Web of Science, LILACS/BBO, and Cochrane Library. Only RCTs published in peer-reviewed journals were included. The compliance with the CONSORT was evaluated in a 0-2 scale where 0 = no description, 1 = poor description and 2 = adequate description. Descriptive analyses of the CONSORT mean score by journal, country, and RoB were performed. The RoB in RCTs was evaluated by using the Cochrane Collaboration's tool version 1.0. RESULTS A total of 15,476 studies were identified after duplicates removal. O only 202 meet the eligibility criteria, among which 31 were follow-up studies. Concerning the overall RoB, only 29 out of 171 were classified as low risk of bias. The overall mean CONSORT score was 19 ± 5.4 points, which means compliance of approximately 59%. Significant differences among countries, publication period, and RoB were observed (p < 0.001). The journal's impact factor was not correlated with the overall CONSORT score (p = 0.36). CONCLUSIONS The adherence of RCTs conducted in posterior restorations to the CONSORT Statement is still low. In addition, most studies were classified as at unclear risk of bias. These results call up an urgent need for improvement. CLINICAL RELEVANCE Most RCTs conducted in posterior teeth have poor reporting and are mainly classified as having an unclear risk of bias.
Collapse
Affiliation(s)
- Márcia Rezende
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil
| | | | - Jadson Araújo da Silva
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil
| | - Alessandra Reis
- Department of Dentistry, State University of Ponta Grossa, Avenida Carlos Cavalcanti, 4748, Paraná, 84030-900, Brazil
| | - Juliana Larocca de Geus
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil.
| |
Collapse
|
18
|
Behera R, Mishra L, Divakar DD, Al-Kheraif AA, Singh NR, Lukomska-Szymanska M. The One-Year In Vivo Comparison of Lithium Disilicate and Zirconium Dioxide Inlays. MATERIALS 2021; 14:ma14113102. [PMID: 34198824 PMCID: PMC8200959 DOI: 10.3390/ma14113102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/01/2021] [Accepted: 06/01/2021] [Indexed: 11/24/2022]
Abstract
The objective of the present study was to evaluate the one-year clinical performance of lithium disilicate (LD) and zirconium dioxide (ZrO2) class II inlay restorations. Thirty healthy individuals who met the inclusion criteria were enrolled for the study. The patients were randomly divided into two study groups (n = 15): LD (IPS e.max press) and ZrO2 (Dentcare Zirconia). In the ZrO2 group, the internal surfaces of the inlays were sandblasted and silanized with Monobond N (Ivoclar, Leichsteistein, Germany). In the LD group, the internal surfaces of the inlays were etched with 5% hydrofluoric acid. The ceramic inlays were cemented with self-cure resin cement (Multilink N). Clinical examinations were performed using modified United State Public Health Codes and Criteria (USPHS) after 2 weeks, 4 weeks, 6 months and 1 year. The one-year survival rate was evaluated. In total, one failure was observed in the ZrO2 group. The survival probability after 1 year for the ZrO2 inlays was 93%, and for the LD inlays was 100%, which was statistically insignificant. The differences between both groups for most USPHS criteria (except for colour match) were statistically insignificant. Within the imitations of the present study, the lithium disilicate- and zirconia dioxide-based inlays exhibited comparable clinical performances. However, the colour and translucency match was superior for the lithium disilicate restorations.
Collapse
Affiliation(s)
- Rini Behera
- Department of Conservative Dentistry & Endodontics, Institute of Dental Sciences, Siksha ’O’ Anusandhan, Bhubaneswar P.O. Box 751003, India; (R.B.); (L.M.); (N.R.S.)
| | - Lora Mishra
- Department of Conservative Dentistry & Endodontics, Institute of Dental Sciences, Siksha ’O’ Anusandhan, Bhubaneswar P.O. Box 751003, India; (R.B.); (L.M.); (N.R.S.)
| | - Darshan Devang Divakar
- Dental Biomaterials Research Chair, Department of Health Department, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 10219, Saudi Arabia; (D.D.D.); (A.A.A.-K.)
| | - Abdulaziz A. Al-Kheraif
- Dental Biomaterials Research Chair, Department of Health Department, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 10219, Saudi Arabia; (D.D.D.); (A.A.A.-K.)
| | - Naomi Ranjan Singh
- Department of Conservative Dentistry & Endodontics, Institute of Dental Sciences, Siksha ’O’ Anusandhan, Bhubaneswar P.O. Box 751003, India; (R.B.); (L.M.); (N.R.S.)
| | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska St, 92-213 Lodz, Poland
- Correspondence:
| |
Collapse
|
19
|
Hardan L, Sidawi L, Akhundov M, Bourgi R, Ghaleb M, Dabbagh S, Sokolowski K, Cuevas-Suárez CE, Lukomska-Szymanska M. One-Year Clinical Performance of the Fast-Modelling Bulk Technique and Composite-Up Layering Technique in Class I Cavities. Polymers (Basel) 2021; 13:1873. [PMID: 34200021 PMCID: PMC8200224 DOI: 10.3390/polym13111873] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 06/01/2021] [Accepted: 06/02/2021] [Indexed: 12/20/2022] Open
Abstract
The aim of this study was to assess the one year clinical performance of a new application method, the Fast-Modelling Bulk Technique (FMBT), in comparison to the Composite-Up Layering Technique (CULT) in posterior cavities. Thirty patients with two class I cavities on permanent human molars were enrolled in the present study. A total of sixty class I cavities were prepared and randomly divided according to the restoration technique used: 30 cavities restored by incremental layering technique and modelling of the last layer with Composite-Up Technique (CUT) using the composite Filtek Z250XT (3M ESPE; St. Paul, MN, USA) and the other 30 restored by Bulk Filling technique and modelling of the last layer by Fast-Modelling Technique (FMT) using the composite Filtek Bulk Fill Posterior Restorative (3M ESPE; St. Paul, MN, USA). Restorations were evaluated for up to one year by two observers according to Federation Dentaire Internationale (FDI) criteria, through clinical and radiological exams. Exact Fisher tests were used for statistical analysis. (p ≤ 0.05). From a biological perspective, at baseline, teeth restored with both techniques did not reveal any postoperative sensitivity. However, with time, FMBT showed less postoperative sensitivity and therefore more desirable results than CULT with a nonsignificant difference after one year (p > 0.05). Concerning secondary caries, fracture of the material, and marginal adaptation, no significant difference was noted between both techniques (p > 0.05). Regarding marginal staining, CULT resulted in more staining with a significant difference, as compared to FMBT (p < 0.05). Upon radiological examination, FMBT showed a good marginal fit during the first year, whereas CULT showed small empty voids from baseline with a nonsignificant difference (p = 1.00). After one year of clinical function, both techniques showed promising results. The present study indicates that the new FMBT could have a positive effect on the marginal staining of resin composite.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.); (M.G.); (S.D.)
| | - Layla Sidawi
- Department of Prosthetic Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon;
| | - Murad Akhundov
- Dental Update Clinic, Mammad Araz Street 102, Baku AZ 1069, Azerbaijan;
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.); (M.G.); (S.D.)
| | - Maroun Ghaleb
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.); (M.G.); (S.D.)
| | - Sarah Dabbagh
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon; (L.H.); (R.B.); (M.G.); (S.D.)
| | - Krzysztof Sokolowski
- Department of Restorative Dentistry, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland;
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca 42160, Hidalgo, Mexico;
| | | |
Collapse
|
20
|
Durão MDA, de Andrade AKM, do Prado AM, Veloso SRM, Maciel LMT, Montes MAJR, Monteiro GQDM. Thirty-six-month clinical evaluation of posterior high-viscosity bulk-fill resin composite restorations in a high caries incidence population: interim results of a randomized clinical trial. Clin Oral Investig 2021; 25:6219-6237. [PMID: 33821322 DOI: 10.1007/s00784-021-03921-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 03/29/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVES This study compared the clinical performance of two bulk-fill (BF) and one conventional resin composite in a population with a high caries incidence. MATERIALS AND METHODS A total of 138 class I and II restorations were performed and randomly divided into three groups (n = 46) with equal allocation: Filtek BF (FBF; 3M ESPE), Tetric EvoCeram BF (TBF; Ivoclar Vivadent), and control Filtek Z250 (Z250; 3M ESPE). The evaluations were performed using the USPHS and FDI criteria at baseline and after 12 and 36 months by a previously calibrated evaluator. The Friedman and Wilcoxon tests for paired data were used for statistical analysis (α = 0.05). RESULTS The DMFT index at baseline was 9.44, with 87% from the decayed component. After 36 months, 108 restorations (n = 36) were evaluated. Two failures were observed for TBF at marginal adaptation and recurrence of caries, resulting in a survival rate of 94.44% and an annual failure rate (AFR) of 1.26%. No equivalence was observed between the criteria for surface roughness, marginal adaptation, and discoloration. CONCLUSIONS The 36-month clinical performance of high-viscosity BF resin composites was comparable to conventional incremental-filled resin composites. The FDI criteria better presented the restorations' clinical success. However, in the case of failure, both criteria provided the same result. CLINICAL RELEVANCE High-viscosity bulk-fill resin composites showed excellent performance after 36 months in a high caries incidence population. It can be considered a simplified alternative restoration method that reduces operating time and minimizes possible operator errors.
Collapse
Affiliation(s)
- Márcia de Almeida Durão
- Faculdade de Odontologia, Universidade de Pernambuco, Av. Gov. Agamenon Magalhães, s/n; Santo Amaro, Recife, Pernambuco, 50.100-010, Brazil
| | - Ana Karina Maciel de Andrade
- Departamento de Dentística Restauradora, Faculdade de Odontologia, Universidade Federal da Paraíba, Cidade Universitária, s/n -, Castelo, Branco III, Paraíba, 58.051-085, Brazil
| | - Amanda Maciel do Prado
- Faculdade de Odontologia, Universidade de Pernambuco, Av. Gov. Agamenon Magalhães, s/n; Santo Amaro, Recife, Pernambuco, 50.100-010, Brazil
| | - Sirley Raiane Mamede Veloso
- Faculdade de Odontologia, Universidade de Pernambuco, Av. Gov. Agamenon Magalhães, s/n; Santo Amaro, Recife, Pernambuco, 50.100-010, Brazil
| | - Lynn Morena Tavares Maciel
- Faculdade de Odontologia, Universidade de Pernambuco, Av. Gov. Agamenon Magalhães, s/n; Santo Amaro, Recife, Pernambuco, 50.100-010, Brazil
| | | | - Gabriela Queiroz de Melo Monteiro
- Faculdade de Odontologia, Universidade de Pernambuco, Av. Gov. Agamenon Magalhães, s/n; Santo Amaro, Recife, Pernambuco, 50.100-010, Brazil.
| |
Collapse
|
21
|
Yu J, Zhang Z, Guo R, Peng W, Yang H, Huang C. Epigallocatechin-3-gallate/nanohydroxyapatite platform delivery approach to adhesive-dentin interface stability. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 122:111918. [DOI: 10.1016/j.msec.2021.111918] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/07/2021] [Accepted: 01/24/2021] [Indexed: 01/31/2023]
|
22
|
Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial. Lasers Med Sci 2021; 36:1109-1116. [PMID: 33392782 DOI: 10.1007/s10103-020-03213-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 11/26/2020] [Indexed: 10/22/2022]
Abstract
The aim of this study was to evaluate the effect of 940 nm laser diode on class II composite cavities prior to bonding and restoration process on the postoperative sensitivity (POS). Thirty patients with two bilateral premolars with mesio or disto-occlusal carious lesions were evaluated. In each patient, the teeth were randomly divided into the control and laser groups. After cavity preparation and isolation and before the bonding process, the laser group was subjected to 940 nm irradiation (Epic 10, Biolase, USA) by 400 μ tip continuously at 100 mW with 398 J/cm2 energy density of tip, which was applied for 5 s at a distance of 2 mm on the axial wall of the cavity. In the control group, irradiation was performed by using the aiming beam. Access cavity was then restored with a composite resin. Cold sensitivity was measured using a cold spray application on the middle third of teeth buccal surface at baseline (before the intervention), 1, 14, and 30 days after the restoration by visual analog scale (VAS) criteria. The mean Friedman and Wilcoxon signed-rank tests were used for data analysis. It was shown that in both laser and control groups, the VAS was significantly decreased at all times compared to the baseline (p ≤ 0.05). There was no statistically significant difference between the mean VAS of two groups at baseline and first day (p ≤ 0.05), but at 14 and 30 days after the intervention, it was significantly lower in the laser group (p ≤ 0.05). The results of this study demonstrated that the cavity pretreatment with laser diode (940 nm) effectively reduces the postoperative sensitivity in class II composite restorations.
Collapse
|
23
|
Perdigão J, Araujo E, Ramos RQ, Gomes G, Pizzolotto L. Adhesive dentistry: Current concepts and clinical considerations. J ESTHET RESTOR DENT 2020; 33:51-68. [PMID: 33264490 DOI: 10.1111/jerd.12692] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Accepted: 11/16/2020] [Indexed: 01/07/2023]
Abstract
OBJECTIVES To address contemporary concepts in adhesive dental materials with emphasis on the evidence behind their clinical use. OVERVIEW Adhesive dentistry has undergone major transformations within the last 20 years. New dental adhesives and composite resins have been launched with special focus on their user-friendliness by reducing the number of components and/or clinical steps. The latest examples are universal adhesives and universal composite resins. While clinicians prefer multipurpose materials with shorter application times, the simplification of clinical procedures does not always result in the best clinical outcomes. This review summarizes the current evidence on adhesive restorative materials with focus on universal adhesives and universal composite resins. CONCLUSIONS (a) Although the clinical behavior of universal adhesives has exceeded expectations, dentists still need to etch enamel to achieve durable restorations; (b) there is no clinical evidence to back some of the popular adjunct techniques used with dental adhesives, including glutaraldehyde-based desensitizers and matrix metalloproteinase inhibitors; and (c) the color adaptation potential of new universal composite resins has simplified their clinical application by combining multiple shades without using different translucencies of the same shade. CLINICAL SIGNIFICANCE New adhesive restorative materials are easier to use than their predecessors, while providing excellent clinical outcomes without compromising the esthetic quality of the restorations.
Collapse
Affiliation(s)
- Jorge Perdigão
- Department of Restorative Sciences, Division of Operative Dentistry, University of Minnesota, Minneapolis, Minnesota, USA
| | - Edson Araujo
- Department of Comprehensive Care, School of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - Renato Q Ramos
- Department of Operative Dentistry, School of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil
| | - George Gomes
- George Gomes Dental Center, Oeiras, Lisbon, Portugal
| | - Lucas Pizzolotto
- Department of Dental Materials, Faculty of Dental Sciences, Federal University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
24
|
Arbildo-Vega HI, Lapinska B, Panda S, Lamas-Lara C, Khan AS, Lukomska-Szymanska M. Clinical Effectiveness of Bulk-Fill and Conventional Resin Composite Restorations: Systematic Review and Meta-Analysis. Polymers (Basel) 2020; 12:polym12081786. [PMID: 32785019 PMCID: PMC7464794 DOI: 10.3390/polym12081786] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/01/2020] [Accepted: 08/07/2020] [Indexed: 12/11/2022] Open
Abstract
The objective of this systematic review and meta-analysis was to determine the clinical effectiveness of bulk-fill and conventional resin in composite restorations. A bibliographic search was carried out until May 2020, in the biomedical databases Pubmed/MEDLINE, EMBASE, Scopus, CENTRAL and Web of Science. The study selection criteria were: randomized clinical trials, in English, with no time limit, with a follow-up greater than or equal to 6 months and that reported the clinical effects (absence of fractures, absence of discoloration or marginal staining, adequate adaptation marginal, absence of post-operative sensitivity, absence of secondary caries, adequate color stability and translucency, proper surface texture, proper anatomical form, adequate tooth integrity without wear, adequate restoration integrity, proper occlusion, absence of inflammation and adequate point of contact) of restorations made with conventional and bulk resins. The risk of bias of the study was analyzed using the Cochrane Manual of Systematic Reviews of Interventions. Sixteen articles were eligible and included in the study. The results indicated that there is no difference between restorations with conventional and bulk resins for the type of restoration, type of tooth restored and restoration technique used. However, further properly designed clinical studies are required in order to reach a better conclusion.
Collapse
Affiliation(s)
- Heber Isac Arbildo-Vega
- Department of General Dentistry, Dentistry School, Universidad San Martín de Porres, Chiclayo 14012, Peru;
- Department of General Dentistry, Dentistry School, Universidad Particular de Chiclayo, Chiclayo 14012, Peru
| | - Barbara Lapinska
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland;
| | - Saurav Panda
- Department of Periodontics and Oral Implantology, Siksha ‘O’ Anusandhan Univeristy, Bhubaneswar 751003, India;
- Department of Biomedical, Surgical and Dental Sciences, Universita Degli Studi di Milano, 20122 Milano, Italy
| | - César Lamas-Lara
- Department of General Dentistry, Stomatology School, Universidad Peruana Los Andes, Lima 15072, Peru;
| | - Abdul Samad Khan
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia;
| | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland;
- Correspondence: ; Tel.: +48-42-675-74-61
| |
Collapse
|
25
|
Francisconi-Dos-Rios LF, Tavares JAO, Oliveira L, Moreira JC, Nahsan FPS. Functional and aesthetic rehabilitation in posterior tooth with bulk-fill resin composite and occlusal matrix. Restor Dent Endod 2020; 45:e9. [PMID: 32110538 PMCID: PMC7030967 DOI: 10.5395/rde.2020.45.e9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 10/20/2019] [Accepted: 11/21/2019] [Indexed: 01/21/2023] Open
Abstract
The restorative procedure in posterior teeth involves clinical steps related to professional skill, especially when using the incremental technique, which may fail in the long term. A recent alternative is bulk-fill resins, which can reduce polymerization shrinkage, decreasing clinical problems such as marginal leakage, secondary caries, and fracture. This scientific study aims to report a clinical case using bulk-fill resin with an occlusal matrix. As determined in the treatment plan, an acrylic resin matrix was produced to establish an improved oral and aesthetic rehabilitation of the right mandibular first molar, which presented a carious lesion with dentin involvement. The occlusal matrix is a simple technique that maintains the original dental anatomy, showing satisfactory results regarding function and aesthetic rehabilitation.
Collapse
|
26
|
Tardem C, Albuquerque EG, Lopes LDS, Marins SS, Calazans FS, Poubel LA, Barcelos R, Barceleiro MDO. Clinical time and postoperative sensitivity after use of bulk-fill (syringe and capsule) vs. incremental filling composites: a randomized clinical trial. Braz Oral Res 2019; 33:e089. [PMID: 31531552 DOI: 10.1590/1807-3107bor-2019.vol33.0089] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Accepted: 08/16/2019] [Indexed: 11/22/2022] Open
Abstract
The objectives of this double-blind randomized clinical trial were to compare (a) the clinical times and (b) the occurrence and severity of postoperative sensitivity, of posterior restoration that used a universal adhesive, in a self-etch or selective enamel-etching technique, along with incremental or bulk-fill composites (presented in syringes or capsules). A total of 295 posterior restorations were placed according to the following groups: SETB - self-etch/bulk-fill in syringe; SETC - self-etch/bulk-fill in capsules; SETI - self-etch/incremental; SEEB - selective enamel-etching/bulk-fill in syringe; SEEC - selective enamel-etching/bulk-fill in capsules; and SEEI - selective enamel-etching/incremental. Clinical time was assessed by a reason (s/mm3) between the total volume of resin inserted and the total time required to perform the restorations. Postoperative sensitivity was evaluated using two scales (Numeric Rating Scale and Visual Analogue Scale). Mean clinical time results, analyzed by Wald's Chi-square, showed significant statistical differences among all groups (p<0.001), indicating that the restorative strategy affected the time required for the restoration. A generalized estimating equation model statistical analysis, performed to compare postoperative sensitivity, showed that neither the restorative technique, the adhesive strategy nor the presentation mode of the bulk-fill composite affected the overall risk of postoperative sensitivity (4.06 [2.22-6.81]). The use of bulk-fill composite, presented in capsules or syringes, is less time consuming and does not increase the risk or intensity of postoperative sensitivity relative to the traditional incremental technique.
Collapse
Affiliation(s)
- Chane Tardem
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Elisa Gomes Albuquerque
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Letícia de Souza Lopes
- Universidade do Estado do Rio de Janeiro - UERJ, Departamento de Dentística, Rio de Janeiro, RJ, Brasil
| | - Stella Soares Marins
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Fernanda Signorelli Calazans
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Luiz Augusto Poubel
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Roberta Barcelos
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| | - Marcos de Oliveira Barceleiro
- Universidade Federal Fluminense - UFF, Instituto de Saúde de Nova Friburgo, Departamento de Formação Específica, Nova Friburgo, RJ, Brasil
| |
Collapse
|
27
|
Aboelenein AZ, Riad MI, Haridy MF. Effect of a Self-Etch Adhesive Containing Nanobioglass on Postoperative Sensitivity of Posterior Composite Restorations - A Randomized Trial. Open Access Maced J Med Sci 2019; 7:2313-2320. [PMID: 31592280 PMCID: PMC6765095 DOI: 10.3889/oamjms.2019.585] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/27/2019] [Accepted: 06/28/2019] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Postoperative sensitivity is one of the major problems regarding posterior resin composite restorations that causes patient discomfort, maybe a reason for replacement of the restoration with an additional office time. AIM To evaluate the effect of the addition of a Nanobioglass to a self-etch adhesive on the reduction of post-operative sensitivity following composite restorations versus a self-etch adhesive that is free of Nanobioglass agent. MATERIALS AND METHODS Sixteen patients having class II carious lesions were included in the study. After cavity preparation, each tooth was randomised to one of the following restorative treatments. Teeth in the control group were restored using self-etch adhesive (OptiBond All-In-One, Kerr) that is free of nanobioglass agent, and nano-hybrid resin composite (Herculite Ultra, Kerr). Restoration of teeth in the experimental group was similar to the control except that a nanobioglass agent was added to the self-etch adhesive. Patients were contacted for evaluation of postoperative sensitivity at 1 day, 1 week, 1 month, and 3 months. Data were analyzed using friedmann test followed by fisher exact test. RESULTS The experimental group (self-etch adhesive containing nanobioglass) showed a significantly less postoperative sensitivity compared with the control group (Self-etch adhesive free of nanobioglass) at 1 day, and 1-week evaluation periods. While both groups did not possess any significant difference at 1 month, and 3 months periods. CONCLUSION The problem of postoperative sensitivity following resin composite restorations could be solved by the addition of bioglass nanoparticles into dental adhesives.
Collapse
Affiliation(s)
| | - Mona Ismail Riad
- Operative Dentistry Department, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt
| | - Mohammed Fouad Haridy
- Operative Dentistry Department, Faculty of Oral and Dental Medicine, Cairo University, Cairo, Egypt.,Operative Dentistry Department, British University in Egypt, Cairo, Egypt
| |
Collapse
|
28
|
Loguercio AD, Rezende M, Gutierrez MF, Costa TF, Armas-Vega A, Reis A. Randomized 36-month follow-up of posterior bulk-filled resin composite restorations. J Dent 2019; 85:93-102. [PMID: 31100332 DOI: 10.1016/j.jdent.2019.05.018] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 05/10/2019] [Accepted: 05/13/2019] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVE The aim of this double blind, randomized controlled trial was to evaluate the 36-month clinical performance of the layering technique (incremental [IF] vs. bulk-fill [BF]) in posterior composite resin restorations bonded with self-etch (SE) and etch-and-rinse (ER) strategies. METHODS Posterior dental cavities of 72 participants (n = 236), with a cavity depth of at least 3 mm, were randomly divided into four groups. The restorations were bonded using either the Tetric N-Bond ER or Tetric N-Bond SE. The composite resin Tetric N-Ceram Bulk-Fill was placed either IF or using BF. Two experienced and calibrated examiners evaluated the restorations using FDI criteria in the baseline and after 12, 24 and 36-month. The statistical analyses were performed using the Wilcoxon Signed rank test (α = 0.05) RESULTS: After 36-month, 14, 21 and 33 restorations showed minor fractures, marginal desadaptation and color mismatch, respectively (p > 0.05). Thirty-three restorations showed some marginal discoloration after 36-month with significant difference between ER (3 for ER-IF; 3 for ER-BF) and SE (14 for SE-IF; 12 for SE-BF; p < 0.05). CONCLUSION The BF technique showed excellent clinical performance, which was comparable during the 36-month of clinical evaluation with the 2-mm IF and it was not affected by the adhesive strategy. However, using the ER strategy reduces the risk of some marginal discoloration, irrespectively of the filling technique. CLINICAL RELEVANCE The bulk-fill material showed excellent clinical behavior when compared to its use in an incremental filling technique, mainly when associated to etch-and-rinse adhesive material after 3 years of clinical evaluation.
Collapse
Affiliation(s)
- A D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil; School of Dentistry, Federal University of Parana, Curitiba, Brazil.
| | - M Rezende
- Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil; Paulo Picanco School of Dentistry, Fortaleza, Ceara, Brazil
| | - M F Gutierrez
- Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil; Institute for Research in Dental Science, Faculty of Dentistry, University of Chile, Chile
| | - T F Costa
- School of Dentistry, Federal University of Parana, Curitiba, Brazil
| | - A Armas-Vega
- Facultad de Ciencias de la Salud Eugenio Espejo, Universidad UTE, Quito, Equador
| | - A Reis
- Department of Restorative Dentistry, State University of Ponta Grossa, Paraná, Brazil
| |
Collapse
|
29
|
Frascino S, Fagundes TC, Silva U, Rahal V, Barboza A, Santos PH, Briso A. Randomized Prospective Clinical Trial of Class II Restorations Using Low-shrinkage Flowable Resin Composite. Oper Dent 2019; 45:19-29. [PMID: 31034347 DOI: 10.2341/18-230-c] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE The aim of this prospective, randomized, split-mouth clinical trial was to evaluate postoperative sensitivity, clinical performance, and interproximal contacts after using different restorative systems. METHODS AND MATERIALS Fifty-three subjects each received three class II restorations according to the restorative systems: conventional resin composite (PA: Peak Universal+Amelogen Plus, Ultradent), low-shrinkage flowable and nanoparticulate resin composites (ABF: Adper Single Bond 2+Filtek Bulk Fill Flow+Filtek Z350XT, 3M ESPE), and low-shrinkage flowable and microhybrid resin composites (XST: XP Bond+SDR+TPH3, Dentsply). Postoperative sensitivity was assessed at 24 hours, seven days, 90 days, and six months. The clinical performance and interproximal contacts were evaluated at baseline, six months, and one year. Friedman, Wilcoxon, Kruskal-Wallis, and Mann-Whitney tests were used to evaluate postoperative sensitivity and interproximal contacts. The equality test of two proportions and logistic regression analysis were used to assess the clinical performance. RESULTS No statistically significant differences were observed among groups for postoperative sensitivity. The highest spontaneous sensitivity was reported at 24 hours. ABF was the only group that did not present a reduction in cold sensitivity. Color, marginal discoloration, and superficial staining showed differences among the groups. XST did not show superficial staining after one year. No differences were observed among groups in relation to interproximal contacts. XST resulted in the loss of interproximal contact after one year. CONCLUSIONS Different types of restorative systems do not influence postoperative sensitivity; however, ABF maintained cold sensitivity over time. Marginal discoloration occurred for all groups but occurred earliest for PA. XST presented a reduction of interproximal contact after one year of evaluation.
Collapse
|
30
|
Veloso SRM, Lemos CAA, de Moraes SLD, do Egito Vasconcelos BC, Pellizzer EP, de Melo Monteiro GQ. Clinical performance of bulk-fill and conventional resin composite restorations in posterior teeth: a systematic review and meta-analysis. Clin Oral Investig 2018; 23:221-233. [PMID: 29594349 DOI: 10.1007/s00784-018-2429-7] [Citation(s) in RCA: 96] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Accepted: 03/19/2018] [Indexed: 01/01/2023]
Abstract
OBJECTIVES The purpose of this systematic review was to compare the clinical performance of bulk-fill resin composites with conventional resin composites used for direct restorations of posterior teeth. METHODS This review followed the PRISMA statement. This review was registered at PROSPERO (registration number CRD42016053436). A search of the scientific literature was performed by two independent reviewers using the PubMed/MEDLINE, Embase, The Cochrane Library, and Web of Science databases from commencement until January 2018. The research question was "Do bulk-fill resin composites have a clinical performance comparable to conventional resin composites in posterior restorations?" Only studies evaluating class I and II direct restorations in permanent teeth with a follow-up period of at least 1 year were included. The RevMan 5 program was used for meta-analysis, calculating the relative risk (RR) and 95% confidence interval (CI) of the dichotomous outcome (restoration failure or success). RESULTS Ten articles were selected, comprising 941 analyzed restorations. The mean follow-up period was 33.6 months (12-72 months). No statistically significant differences in the failure rate were observed between conventional and base/flowable bulk-fill resin composites (p = 0.31; RR 1.49; 95% CI 0.69-3.25) or full-body/sculptable bulk-fill resin composites (p = 0.12; RR 1.89; 95% CI 0.84-4.24). CONCLUSIONS The present systematic review and meta-analysis indicate similar clinical performances of bulk-fill and conventional resin composites over a follow-up period of 12 to 72 months. CLINICAL SIGNIFICANCE Based on the results of this study, the bulk-fill resin composites could be an alternative for direct restorations in posterior teeth. However, clinical trials of longer duration are required.
Collapse
Affiliation(s)
- Sirley Raiane Mamede Veloso
- Dental School, Universidade de Pernambuco/FOP-UPE, Av. General Newton Cavalcanti, 1650; Tabatinga, Camaragibe, PE, 54.756-220, Brazil
| | - Cleidiel Aparecido Araújo Lemos
- Araçatuba Dental School, UNESP - Univ Estadual Paulista , R. José Bonifácio, 1193; Vila Mendonca, Araçatuba, SP, 16015-050, Brazil
| | - Sandra Lúcia Dantas de Moraes
- Dental School, Universidade de Pernambuco/FOP-UPE, Av. General Newton Cavalcanti, 1650; Tabatinga, Camaragibe, PE, 54.756-220, Brazil
| | | | - Eduardo Piza Pellizzer
- Araçatuba Dental School, UNESP - Univ Estadual Paulista , R. José Bonifácio, 1193; Vila Mendonca, Araçatuba, SP, 16015-050, Brazil
| | - Gabriela Queiroz de Melo Monteiro
- Dental School, Universidade de Pernambuco/FOP-UPE, Av. General Newton Cavalcanti, 1650; Tabatinga, Camaragibe, PE, 54.756-220, Brazil.
| |
Collapse
|
31
|
Annual review of selected scientific literature: Report of the committee on scientific investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2017; 118:281-346. [DOI: 10.1016/j.prosdent.2017.04.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Revised: 04/27/2017] [Accepted: 04/27/2017] [Indexed: 01/19/2023]
|