de Azevedo MR, Pacheco RR, Qualhato LB, Dolenkei KK, Soares CJ, Raposo LH. Impact of Battery Levels of a Cordless LED Curing Unit on Resin Cement under Varied Lithium Disilicate Thicknesses and Translucencies. Oper Dent 2024; 49:704-713. [PMID: 39407441 DOI: 10.2341/24-018-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/25/2024] [Indexed: 11/07/2024]
Abstract
OBJECTIVES This study aimed to evaluate the impact of battery levels on the emission of a multi-peak cordless LED light-curing unit (LCU) and the effect on the degree of conversion (DC) and Knoop hardness (KH) of a light-cure resin luting agent activated through varying lithium disilicate (LiS2) ceramic thicknesses and translucencies. METHODS High and low translucency LiS2 discs (IPS e.max Press HT and LT, respectively; shade A1) with thickness of 0.5, 1.0, 1.5, and 2.0 mm were fabricated. Resin luting agent specimens (Variolink Esthetic LC) were prepared and cured using a Bluephase G2 LCU at different battery levels (100%, 50%, and 10%) through the LiS2 ceramics. The transmitted irradiance was evaluated using USB4000 MARC, while FTIR and a microhardness tester assessed DC and KH, respectively. After ensuring homoscedasticity, the data wee analyzed using analysis of variance and Tukey HSD test (α=0.05). RESULTS The study found strong positive correlations between battery levels and irradiance, particularly with no ceramic interposition and through HT ceramics (R2=0.9471), although this correlation diminished with thicker HT (R2=0.7907) and LT ceramics (R2<0.2980). Both battery levels and ceramic thickness significantly influenced transmitted irradiance (p<0.0001), resulting in lower values with decreased battery levels and increased ceramic thicknesses (p<0.0001). LT ceramics showed lower transmittance than HT. DC was significantly affected by both battery levels and ceramic thicknesses, with generally lower DC values except for LT ceramics at a 10% battery level (p<0.0001). No significant differences in DC were observed between HT and LT translucencies (p=0.548). KH was higher in HT than LT ceramics at 100% and 50% battery levels, with thicker ceramics showing lower KH values at 10% battery level (p<0.0001). Conclusion: Reduced battery levels in cordless LED curing units significantly affect the irradiance, degree of conversion, and hardness of light-curable resin luting agents. Maintaining battery levels above 50% is recommended for optimal performance. Thicker and more opaque ceramics significantly impacted incident irradiance. However, preserving radiant energy could potentially mitigate these limitations.
Collapse
Affiliation(s)
- M R de Azevedo
- Michele Ramos de Azevedo, DDS, MSc, graduate student, Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil
| | - R R Pacheco
- Rafael Rocha Pacheco, DDS, MSc, PhD, associate professor and section director of Dental Materials, Department of Restorative Sciences, Dental College of Georgia at Augusta University, GA, USA
| | - L B Qualhato
- Letícia Bruno Qualhato, DDS, graduate student, Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil
| | - K K Dolenkei
- Karen Katlein Dolenkei, DDS, MSc, graduate student, Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil
| | - C J Soares
- Carlos José Soares, DDS, MSc, PhD, full professor, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil
| | - L H Raposo
- *Luís Henrique Araújo Raposo, DDS, MSc, PhD, associate professor, Department of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlândia, MG, Brazil
| |
Collapse
|
2
|
Lim HK, Keerthana S, Song SY, Li C, Shim JS, Ryu JJ. Effect of Light Irradiance and Curing Duration on Degree of Conversion of Dual-Cure Resin Core in Various Cavities with Different Depths and Diameters. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4342. [PMID: 39274732 PMCID: PMC11396115 DOI: 10.3390/ma17174342] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/09/2024] [Accepted: 08/23/2024] [Indexed: 09/16/2024]
Abstract
(1) Background: To compare the degree of conversion of resin cores in various types of cavities and determine an effective irradiation method for achieving a higher degree of conversion. (2) Methods: Four different-sized cavities (narrow-shallow, narrow-deep, wide-shallow, and wide-deep) were simulated using a Teflon mold. The light irradiance reaching the bottom of each mold was measured by positioning a radiometer. The degree of conversion of the dual-cure resin core after irradiation (400 mW/cm2 for 20 s, 400 mW/cm2 for 40 s, and 800 mW/cm2 for 20 s) was measured using Fourier-transform near-infrared spectroscopy. (3) Results: The highest light irradiance was found at the bottom of wide-shallow cavities, followed by wide-deep, narrow-shallow, and narrow-deep ones (p < 0.001). In narrow cavities, irradiation at 800 mW/cm2 for 20 s led to a significantly higher degree of conversion (p < 0.001). In wide cavities, irradiation at 400 mW/cm2 for 40 s and 800 mW/cm2 for 20 s both led to a significantly higher degree of conversion (p < 0.001). (4) Conclusions: Less curing light reaches the bottom of cavities with a smaller diameter and greater depth. Providing a higher irradiance of light can induce a higher degree of conversion of resin composites in narrower cavities.
Collapse
Affiliation(s)
- Ho-Kyung Lim
- Department of Oral and Maxillofacial Surgery, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea
| | - Subramanian Keerthana
- Graduate School of Clinical Dentistry, Korea University, 46, Gaeunsa 2-gil, Seongbuk-gu, Seoul 02842, Republic of Korea
| | - So-Yeon Song
- Department of Prosthodontics, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea
| | - Chongyang Li
- Graduate School of Clinical Dentistry, Korea University, 46, Gaeunsa 2-gil, Seongbuk-gu, Seoul 02842, Republic of Korea
| | - Ji Suk Shim
- Department of Prosthodontics, Korea University Guro Hospital, 148, Gurodong-ro, Guro-gu, Seoul 08308, Republic of Korea
| | - Jae Jun Ryu
- Department of Prosthodontics, Korea University Anam Hospital, 73, Goryeodae-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| |
Collapse
|
3
|
Moon HK, Won JE, Ryu JJ, Shim JS. The Effect of the Initiator/Activator/Accelerator Ratio on the Degree of Conversion, Film Thickness, Flow, and Cytotoxicity of Dual-Cured Self-Adhesive Resin Cements. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3572. [PMID: 39063864 PMCID: PMC11278755 DOI: 10.3390/ma17143572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 07/15/2024] [Accepted: 07/16/2024] [Indexed: 07/28/2024]
Abstract
Although self-adhesive resin cements are convenient and less technique-sensitive materials for dental clinicians, they exhibit a lower degree of conversion due to acidic components in their composition. Supplementation of the initiator, accelerator, and activator in self-adhesive resin cements has been suggested to compensate for the lower degree of conversion. This study aimed to evaluate the effects of different combinations of self-curing initiators, self-curing activators, and accelerators on the degree of conversion (DC) of self-adhesive resin cements. A dual-cured self-adhesive resin was prepared using six combinations of initiators, activators, and accelerators. The change in the DC over time was evaluated with and without light curing. The film thickness, flow properties, and cytotoxicity of each formulation were assessed. The results showed that all supplemental components had an effect on increasing the DC, but a greater increase in the DC was observed in the following order: activator, accelerator, and initiator. The cytotoxicity of the resin cements was related to the DC values, as resin cements with lower DC values exhibited higher cytotoxicity. The film thickness met the ISO standards for all groups. The results suggest that utilizing an activator is the most effective approach to enhance the DC in self-adhesive resin cement and that cytotoxicity tended to increase with lower DC values, whereas film thickness and flow properties demonstrated no correlation with DC values.
Collapse
Affiliation(s)
- Hyun Kyung Moon
- Department of Biomedical Sciences, College of Medicine, Korea University Guro Hospital, Seoul 08308, Republic of Korea;
| | - Jong-Eun Won
- Institute for Clinical Dental Research, Department of Dentistry, Korea University Guro Hospital, Seoul 08308, Republic of Korea;
| | - Jae Jun Ryu
- Department of Prosthodontics, Korea University Anam Hospital, Seoul 02841, Republic of Korea
| | - Ji Suk Shim
- Institute for Clinical Dental Research, Department of Dentistry, Korea University Guro Hospital, Seoul 08308, Republic of Korea;
- Department of Prosthodontics, Korea University Guro Hospital, Seoul 08308, Republic of Korea
| |
Collapse
|
4
|
Pyo SW, Park K, Daher R, Kwon HB, Han JS, Lee JH. Comparison of the clinical outcomes of resin-modified glass ionomer and self-adhesive resin cementations for full-coverage zirconia restorations. J Dent 2023:104558. [PMID: 37230241 DOI: 10.1016/j.jdent.2023.104558] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 05/17/2023] [Accepted: 05/22/2023] [Indexed: 05/27/2023] Open
Abstract
OBJECTIVES Both resin-modified glass ionomer cement (RMGIC) and self-adhesive resin cement (SAC) may be suitable for cementation of full-coverage zirconia restorations. This retrospective study aimed to investigate the clinical outcomes of zirconia-based restorations cemented with RMGIC and compare them with those cemented with SAC. METHODS Cases of full-coverage zirconia-based restorations cemented with either RMGIC or SAC between March 2016 and February 2019 were evaluated in this study. The clinical outcomes of the restorations were analyzed according to the type of cement used. In addition, cumulative success and survival rates were evaluated according to the cement and abutment types. Non-inferiority, Kaplan-Meier, and Cox hazard tests were conducted (α=.05). RESULTS A total of 288 full-coverage zirconia-based restorations (natural teeth, 157; implant restorations, 131) were analyzed. Loss of retention occurred in only one case; a single-unit implant crown cemented with RMGIC, which decemented 4.25 years post-restoration. RMGIC was non-inferior to SAC in terms of loss of retention (<5%). For single-unit natural tooth restorations, the four-year success rates in the RMGIC and SAC groups were 100% and 95.65%, respectively (p=.122). For single-unit implant restorations, the four-year success rates in the RMGIC and SAC groups were 95.66% and 100%, respectively (p=.365). The hazard ratios of all the predictor variables, including cement type, were not significant (p>.05). CONCLUSIONS Cementation of full-coverage zirconia restorations of both natural teeth and implants using RMGIC and SAC yields satisfactory clinical outcomes. Furthermore, RMGIC is non-inferior to SAC in terms of cementation success. CLINICAL SIGNIFICANCE Cementation with RMGIC or SAC for full-coverage zirconia restorations has favorable clinical outcomes in both natural teeth and implants. Both RMGIC and SAC have advantages in the cementation of full-coverage zirconia restorations to abutments with favorable geometries.
Collapse
Affiliation(s)
- Se-Wook Pyo
- Clinical Assistant Professor, Department of Prosthodontics, Gangnam Severance Hospital, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Koungjin Park
- Graduate Student, Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - René Daher
- Senior Lecturer, Division of Cariology and Endodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - Ho-Beom Kwon
- Dean and Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jung-Suk Han
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jae-Hyun Lee
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.; Program Director and Assistant Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea..
| |
Collapse
|
5
|
Carek A, Dukaric K, Miler H, Marovic D, Tarle Z, Par M. Post-Cure Development of the Degree of Conversion and Mechanical Properties of Dual-Curing Resin Cements. Polymers (Basel) 2022; 14:polym14173649. [PMID: 36080725 PMCID: PMC9460751 DOI: 10.3390/polym14173649] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 11/17/2022] Open
Abstract
This study investigated the effect of different curing conditions on the degree of conversion and mechanical properties of contemporary dual-curing resin cements. The material specimens were either light-cured directly, light-cured through a 1-mm lithium disilicate glass-ceramic layer, or self-cured. The degree of conversion was measured in 0.1-mm films using Fourier-transform infrared spectroscopy 1 day, 7 days, and 28 days post-cure. Specimens used to study the flexural strength and modulus were prepared according to the ISO 4049 protocol, stored for 28 days post-cure, and subjected to accelerated aging by absolute ethanol immersion. The degree of conversion values ranged between 44.3–77.8%. Flexural strength varied between 11.4–111.1 MPa, while flexural modulus amounted to 0.7–5.5 GPa. The degree of conversion was significantly affected by material type, curing conditions, and post-cure time; however, variations in curing conditions were the least influential factor. A statistically significant effect of curing conditions on the degree of conversion was identified for only one of the five materials tested, whereas the flexural strength and modulus of all tested materials were significantly reduced in the experimental groups that were light-cured through a ceramic layer or self-cured. The effect size analysis showed that mechanical properties were most affected by the material type, while the differences in curing conditions were less influential. A comparison of the degree of conversion and mechanical properties indicated that different curing conditions may lead to significantly different flexural strength and modulus, which are not necessarily accompanied by identifiable variations in the degree of conversion.
Collapse
Affiliation(s)
- Andreja Carek
- Department of Fixed Prosthodontics, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Ksenija Dukaric
- School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Helena Miler
- School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
- Correspondence:
| |
Collapse
|
6
|
Okutan Y, Kandemir B, Donmez MB, Yucel MT. Effect of the thickness of CAD-CAM materials on the shear bond strength of light-polymerized resin cement. Eur J Oral Sci 2022; 130:e12892. [PMID: 35969188 DOI: 10.1111/eos.12892] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 07/19/2022] [Indexed: 11/29/2022]
Abstract
This study aimed to investigate the effect of the thickness of computer aided design-computer aided manufacturing (CAD-CAM) restorative materials on the bond strength of light-polymerized resin cement. Ninety specimens were prepared from three different CAD-CAM materials (a leucite-based glass-ceramic [Empress CAD], a polymer-infiltrated ceramic network [Vita Enamic], and a zirconia-reinforced lithium silicate glass-ceramic [Vita Suprinity]) in different thicknesses (1, 2, and 3 mm). One surface of each specimen was treated by using a single-step self-etching ceramic primer (Monobond Etch & Prime). Light-polymerized resin cement was bonded to treated surfaces by exposure to a light-emitting diode curing unit from the untreated side of the samples. Shear bond strength (SBS) between the ceramic and the resin cement was measured by using a universal testing machine. The leucite-based glass-ceramic had higher SBS values than the other materials at each thickness. For each material, 1 mm-thick specimens had the highest SBS values. The difference between the SBS values of 2 mm- and 3 mm-thick polymer-infiltrated ceramic network was nonsignificant, whereas the SBS values of 2 mm-thick leucite-based glass-ceramic and the zirconia-reinforced lithium silicate glass-ceramic were significantly higher than those of the corresponding 3 mm-thick specimens. The choice of the material and its thickness may be highly important for clinical success when light-polymerized resin cements are used for cementation.
Collapse
Affiliation(s)
- Yener Okutan
- Department of Prosthodontics, Faculty of Dentistry, Aydin Adnan Menderes University, Aydin, Turkey
| | - Banucicek Kandemir
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.,Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Munir Tolga Yucel
- Department of Prosthodontics, Faculty of Dentistry, Selcuk University, Konya, Turkey
| |
Collapse
|
7
|
El-Damanhoury HM, Elsahn NA, Sheela S, Albasti AA, Jouma MJ, Albadich MA, Bastaty T, Taghva YS. Impact of Immediate and Delayed Photo-activation of Self-adhesive Resin Cements on Bonding Efficacy and Water Uptake Under Simulated Pulpal Pressure. Oper Dent 2022; 47:337-345. [PMID: 35649220 DOI: 10.2341/21-004-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/28/2021] [Indexed: 11/23/2022]
Abstract
This study investigated the effect of immediate versus delayed photo-activation on the bonding performance and water uptake of self-adhesive (SA) resin cements under simulated pulpal pressure (SPP). The occlusal dentin surface was exposed in 66 extracted third molars. Resin composite cylinders were cemented to dentin under SPP, with either RelyX Unicem 2 (RU) (3M Oral Care, St Paul, MN, USA) or Maxcem Elite (MC) (Kerr, Orange, CA, USA). Each cement group was equally divided into three groups (n=8 each) according to the time elapsed between placement and photo-activation: immediate activation (IM), 30-second delayed activation (D30), or 120-second delayed activation (D120). Shear bond strength (SBS) was measured, and the type of failure was determined using a stereomicroscope. Three additional samples from each experimental subgroup were used for confocal laser scanning microscopy (CLSM) analysis. A fluorescent dye solution was added to the pulpal fluid reservoir, then a CLSM was used to detect the dye distribution within the tooth-restoration interface. Two-way analysis of variance (ANOVA) and the Tukey post-hoc test were used to analyze the SBS results (α=0.05). D30 resulted in a significantly higher mean SBS in the two cement groups than IM and D120 (p<0.05). RU showed significantly higher SBS values than MC regardless of the time of light activation (p<0.05). RU showed less dye uptake confined to the cement-dentin interface compared to the MC groups, which showed dye uptake throughout the entire thickness of the cement layer and gap formation at the interface, especially in the D120 group. The 30-second photo-activation delay group significantly improved the bond strength of SA cements. Delaying the photo-activation to 120 seconds increased pulpal fluid uptake by SA cements and compromised the integrity of the bonded interfaces.
Collapse
Affiliation(s)
- H M El-Damanhoury
- *Hatem M El-Damanhoury, BDS, MDS, PhD, associate professor, Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - N A Elsahn
- Nesrine Ali Elsahn, BDS, MDS, PhD, assistant professor, Department of Restorative Dentistry, College of Dentistry, Ajman University, Ajman, United Arab Emirates; Department of Operative Dentistry, Faculty of Dentistry, Cairo University, Cairo, Egypt
| | - S Sheela
- Soumya Sheela, BDS, MDS, PhD, post-doctoral fellow, Dental Biomaterials Research Group - Sharjah Institute for Medical Research, University of Sharjah, Sharjah, United Arab Emirates
| | - A A Albasti
- Amna A Albasti, BDS, general practitioner, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - M J Jouma
- Mahmoud J Jouma, BDS, general practitioner, College of Dental Medicine, University of Sharjah. Sharjah, United Arab Emirates
| | - M A Albadich
- Marwah A Albadich, BDS, general practitioner, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - T Bastaty
- Talal Bastaty, BDS, general practitioner, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| | - Y S Taghva
- Yalda S Taghva, BDS, general practitioner, College of Dental Medicine, University of Sharjah, Sharjah, United Arab Emirates
| |
Collapse
|
8
|
Fernandes Neto C, Narimatsu MH, Magão PH, da Costa RM, Pfeifer CS, Furuse AY. Physical-chemical characterization and bond strength to zirconia of dental adhesives with different monomer mixtures and photoinitiator systems light-activated with poly and monowave devices. Biomater Investig Dent 2022; 9:20-32. [PMID: 35528027 PMCID: PMC9067976 DOI: 10.1080/26415275.2022.2064289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Introduction: Bonding to crystalline zirconia is currently a challenge. Properly cured adhesives are crucial to optimize this bond, and that in turn is influenced by the initial mobility of the system, as well as by the reactivity of the initiators. Aim: This study aimed to characterize adhesives containing monomer mixtures of different viscosities and double and triple photoinitiator systems; and to evaluate the bonding to Y-TZP zirconia, when adhesives were light-activated with monowave or polywave light-curing units (LCU). Materials and methods: Adhesives were formulated at a 1:1 weight proportion of Bis-GMA/TEGDMA or Bis-GMA/Bis-EMA. To these mixtures 0.5 wt% of CQ, 0.5–1.0 wt% of DABE, 0.5–1.0 wt% of DPIHP, or 0.5–1.0 wt% of TAS-Sb were added and used as photoinitiator systems. A total of ten adhesives were prepared. Resin composite cylinders were cemented on zirconia slices and 6000 thermal cycles were performed. Degree of conversion (DC), sorption (SO) and solubility (SL) after 7 days of water storage, and microshear bond strength (µSBS) were evaluated. Data were analyzed with three-way ANOVA and Tukey’s HSD (α = 0.05). Results: Bis-GMA/Bis-EMA combined with either CQ/DABE or CQ/DABE/TAS-Sb presented the highest DC, and no significant differences were observed for LCUs (p = .298). CQ/DABE < CQ/DABE/TAS-Sb ≈ CQ/DABE/DPIHP and the polywave LCU showed smaller overall SO (p < .05). Bis-GMA/TEGDMA with CQ/DABE cured with the polywave LCU presented the lowest SO. SL varied as follows: CQ/DABE/TAS-Sb < CQ/DABE/DPIHP < CQ/DABE (p < .001). For µSBS, only the factor photoinitiator system was significant (p = .045). All mean values were above 30 MPa, with higher values being observed for BIS-GMA/TEGDMA and CQ/DABE. Conclusion: It can be concluded that the adhesive containing CQ/DABE/TAS-Sb as coinitiator of Bis-GMA/Bis-EMA mixtures produced a material with higher DC and lower SL, while bond strength values were similar to the ones obtained by CQ/DABE.
Collapse
Affiliation(s)
- Constantino Fernandes Neto
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Mayara Hana Narimatsu
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Pedro Henrique Magão
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Reginaldo Mendonça da Costa
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| | - Carmem Silvia Pfeifer
- Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, School of Dentistry, Oregon Health and Science University, Portland, OR, USA
| | - Adilson Yoshio Furuse
- Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
| |
Collapse
|
9
|
Brescansin FN, Prochnow C, Guilardi LF, Kleverlaan CJ, Bacchi A, Valandro LF, Pereira GKR. Effect of different surface treatments on optical, colorimetric, and surface characteristics of a lithium disilicate glass-ceramic. J ESTHET RESTOR DENT 2021; 33:1017-1028. [PMID: 34105868 DOI: 10.1111/jerd.12793] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 04/19/2021] [Accepted: 05/25/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate the effect of surface treatments on optical, colorimetric, and surface characteristics of lithium disilicate glass-ceramic. MATERIALS AND METHODS Specimens (n = 5, IPS e.max CAD) were randomly allocated to the following treatments: mirror-polished: SiC papers; as-cut: mimicking CAD-CAM milling; ground: 90-120 μm-grit diamond bur; ground polished: ground, finished (46-30 μm-grit diamond bur), polished (diamond cups, brush and diamond paste); ground glazed: ground, glazed; ground polished glazed: association of methods. CIELAB color coordinates were obtained by a spectrophotometer. CIEDE2000 color differences (ΔE00 ) and the translucency parameter (TP00 ) were calculated. Light transmittance was assessed with a colorimeter. Surface characteristics (topography and roughness) were analyzed. Statistical differences for each condition and outcome were detected using one-way ANOVA with Tukey's post-hoc test (α = 0.05). RESULTS TP00 data show statistical reduction after grinding (p < 0.05), which was only restored with polishing (solely or with glazing). ΔE00 shows that grinding results in perceptible variations in color (above 0.81), which were restored after all post-processing protocols (exception to only glaze application in contact with a black background). Light transmittance data corroborated such performance. Polishing and glazing reduced roughness and improved surface topography. CONCLUSION Grinding statistically increased roughness, reduced translucency, light transmittance through the ceramic, and resulted on color differences. On contrary, polishing (followed or not by glazing) reduced roughness and enhanced ceramic translucency and light transmittance. Glaze also reduced roughness, but it still presented reduced translucency. The positioning (facing up or down) of the ceramic treated surface influenced the considered outcomes. CLINICAL SIGNIFICANCE Grinding with diamond burs results in a deleterious impact to the optical, colorimetric and surface characteristics of lithium disilicate ceramic. Thus, polishing (followed or not by glazing) is recommended for optical and topographical enhancements when lithium disilicate monolithic restorations require occlusal adjustments.
Collapse
Affiliation(s)
| | - Catina Prochnow
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Luís Felipe Guilardi
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Cornelis Johannes Kleverlaan
- Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Ataís Bacchi
- MSciD Post-Graduate Program in Dentistry, Paulo Picanço School of Dentistry, Fortaleza, Brazil
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontic Unit), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Brazil
| |
Collapse
|
10
|
The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review. Clin Oral Investig 2021; 25:3395-3408. [PMID: 33783593 DOI: 10.1007/s00784-021-03904-w] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
OBJECTIVE The main aim of this study was to conduct an integrative review on the influence of the zirconia veneer thickness on the degree of conversion of resin-matrix cements. MATERIALS AND METHOD An electronic search was performed on PubMed using a combination of the following search items: zirconia, thickness, veneer, degree of conversion, resin cement, light curing, and polymerization. Articles published in the English language, up to July 2020, were included regarding the influence of ceramic veneer thickness on the degree of conversion of resin-matrix cements. Randomized controlled trials and prospective cohort studies were also evaluated. RESULTS Of the 21 selected studies, 9 investigated the light-curing effect, while five other articles evaluated the ceramic translucency. Three studies evaluated the degree of conversion of the resin-matrix cement while four articles assessed the veneer thickness. Results revealed a significant decrease of light transmission through the zirconia with a thickness ranging from 0.1 up to 1.5 mm. However, the ultra-thin thickness around 0.1 and 0.3 mm allowed a full polymerization of the dual-curing resin-matrix cement resulting in the integrity of the interface properties. The light-curing process of resin-matrix cements is also affected by the shade, chemical composition, and microstructure of zirconia and resin cement. Optimal conditions of light-curing are required to reach the threshold intensity of light and energy for polymerization of resin-matrix cements. CONCLUSIONS The increase in zirconia veneer thickness negatively affects the degree of conversion of resin-matrix cements. Also, shade and microstructure are key factor to improve the light curing of resin cements. CLINICAL RELEVANCE Clinicians should consider the zirconia thickness on resin-based cementation since a higher veneer thickness can negatively affect the light irradiation intensity towards the dual-curing resin-matrix cement. Thus, the degree of conversion of the resin-matrix cement can decrease leading to a low chemical stability (e.g., color instability) and poor mechanical properties.
Collapse
|
11
|
Inokoshi M, Nozaki K, Takagaki T, Okazaki Y, Yoshihara K, Minakuchi S, Van Meerbeek B. Initial curing characteristics of composite cements under ceramic restorations. J Prosthodont Res 2020; 65:39-45. [PMID: 32938857 DOI: 10.2186/jpr.jpor_2019_330] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To assess the degree of conversion (DC) of dual-curing composite cements when cured through ceramic-veneered zirconia disks. METHODS Portions of mixed cement, either G-CEM LinkForce (GC), Panavia V5 (Kuraray Noritake) or ResiCEM (Shofu), were placed on the ATR crystal of a Fourier Transform Infrared Spectroscope (FTIR; iS50, Thermo Scientific) and squeezed to a 100-µm film thickness using a microscopy cover glass. DC (%) of the composite cements applied in self-curing mode was measured in the dark at 37°C. Following the dual-curing mode, the cements were light-cured directly (positive control) or through a ceramic-veneered zirconia disk (0.5-mm thick zirconia with a 1.0-mm thick veneering ceramic) for 40 sec using two light-curing units (G-Light Prima 2, GC; PenCure, Morita). Per experimental group, 5 tests were conducted to measure DC in self-cure and dual-cure mode (n=5). FTIR spectra of the composite cement films were acquired to determine DC every min up to 30 min. DC of the composite cements was statistically compared using two-way repeated-measures ANOVA (α=0.05). RESULTS For all cements investigated, the self-curing mode resulted in significantly lower DC at 10, 20 and 30 min than the light-curing mode. When the composite cements were light-cured through the zirconia disk, DC at 30 min dropped significantly for ResiCem (Shofu), while not for Panavia V5 (Kuraray Noritake) and G-CEM LinkForce (GC). CONCLUSIONS Self-curing slows down polymerization but does not reach for all composite cements the highest (light-cured) DC. Ceramic-veneered zirconia-based restorations may affect DC of some composite cements.
Collapse
Affiliation(s)
- Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kosuke Nozaki
- Department of Fixed Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Tomohiro Takagaki
- Department of Operative Dentistry, Division of Oral Functional Science and Rehabilitation, School of Dentistry, Asahi University
| | - Yohei Okazaki
- KU Leuven , Department of Oral Health Sciences, BIOMAT & UZ Leuven , Dentistry, Belgium Department of Advanced Prosthodontics, Division of Dental Sciences, Hiroshima University
| | - Kumiko Yoshihara
- Department of National Institute of Advanced Industrial Science and Technology (AIST),Department of Pathology & Experimental Medicine,Graduate School of Medicine, Okayama University
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Dentistry
| |
Collapse
|
12
|
de Figueiredo EZ, de Souza Balbinot G, Castelo Branco Leitune V, Mezzomo Collares F. Niobium silicate as a filler for an experimental photopolymerizable luting agent. J Prosthodont Res 2020; 65:25-30. [PMID: 32938867 DOI: 10.2186/jpr.jpor_2019_420] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To synthesize niobium silicate particles (SiNb) and incorporate into resin-based luting agents. METHODS SiNb particles were synthesized and characterized by x-ray diffraction, FTIR spectroscopy, particle size, and specific surface area. Luting agents were formulated with 50 wt% BisGMA, 30 wt% TEGDMA and 20 wt% UDMA. BAPO was used as a photoinitiator in 1mol%. The SiNb particles were incorporated into the agents at concentrations of 50 wt% (SiNb50%) or 65% wt% (SiNb65%). Barium glass particles at the same concentrations were used as controls (SiBa50% and SiBa65%). Refractive index, degree of conversion (DC), polymerization kinetics, softening in solvent, radiopacity, film thickness, color stability, flexural strength (FS) and micro shear bond strength (µSBS) were evaluated. RESULTS SiNb particles were successfully synthesized with an adequate structure to be applied as inorganic fillers. SiNb groups had higher DC, lower %ΔKHN, greater film thickness and greater radiopacity than the SiBa groups. Color stability was greater for SiNb50% and SiNb65% after six months of storage, as demonstrated by ΔE00. ΔWID values were lower for the SiBa groups. FS results decreased over time, and lower values were found for SiNb. In µSBS, the values of SiNb65% were higher at 24 h (45.22 MPa) and at six months (36.83 MPa), with statistically differences from values for the SiBa groups. CONCLUSIONS SiNb particles were successfully synthesized using the sol-gel method, and their incorporation into luting agents at a concentration of up to 65% improved the physicomechanical characteristics and color stability of these agents.
Collapse
Affiliation(s)
- Elisa Zancanaro de Figueiredo
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492/4th floor, Porto Alegre, RS
| | - Gabriela de Souza Balbinot
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492/4th floor, Porto Alegre, RS
| | - Vicente Castelo Branco Leitune
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492/4th floor, Porto Alegre, RS
| | - Fabrício Mezzomo Collares
- Dental Materials Laboratory, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492/4th floor, Porto Alegre, RS
| |
Collapse
|
13
|
Shim JS, Lee SY, Song SY, Jha N, Ryu JJ. Polymerization efficiency of dental dual-cured resin cement light-cured at various times after the initiation of chemical activation. INT J POLYM MATER PO 2019. [DOI: 10.1080/00914037.2019.1596912] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Ji Suk Shim
- Department of Prosthodontics, Korea University Ansan Hospital, Republic of Korea
| | - Soo Young Lee
- Department of Medicine, Korea University Graduate School, Republic of Korea
| | - So-Yeon Song
- Department of Biomedical Science, Graduate School of Korea University, Republic of Korea
| | - Nayansi Jha
- Department of Medicine, Korea University Graduate School, Republic of Korea
| | - Jae Jun Ryu
- Department of Prosthodontics, Korea University Anam Hospital, Seoul, Republic of Korea
| |
Collapse
|