1
|
Iwama H, Ishii R, Takamizawa T, Aoki R, Watanabe S, Hayashi K, Kamimoto A, Miyazaki M. Influence of Surface Pretreatment on the Bond Strength of a Resin Luting Cement to Saliva-contaminated Enamel and Dentin. Oper Dent 2024; 49:586-596. [PMID: 39187948 DOI: 10.2341/23-170-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/01/2024] [Indexed: 08/28/2024]
Abstract
OBJECTIVES This study aimed to evaluate the influence of surface pretreatment on the shear bond strength (SBS) of a resin luting cement to enamel and dentin with saliva contamination. The surface free energies (SFE) of the adherent surfaces were also determined. METHODS AND MATERIALS Bovine enamel and dentin were used in this study. For the saliva-contamination, human saliva was applied to the adherent surface for 60 seconds and then air-dried, and the specimens without saliva contamination served as controls. One group of contaminated surfaces was untreated (SC), and the others were pretreated with Katana Cleaner (KC), Multi Etchant (ME), or Ultra-Etch (UE). Fifteen specimens were prepared to measure the SBS for each test group.The mixed resin luting cement paste was applied to the alumina-blasted surface of a stainless-steel rod and placed on the prepared tooth surface. The luting cement was light irradiated for 40 seconds. The bonded specimens were stored for 24 hours at 37°C and half of the bonded specimens underwent 10,000 thermal cycles. The SBS and SFE of the specimens after different pre-treatments were measured. RESULTS The two-way ANOVA revealed that the factors of pretreatment agent and storage condition had a significant effect on the SBS to enamel and dentin. The SFE values of the SC group were significantly lower than those of the other groups in both enamel and dentin. The SFE of pretreated surface was material dependent. CONCLUSIONS A pretreatment agent containing functional monomers was shown to be effective in removing saliva contaminants and in creating an effective bonding surface for the resin luting cement.
Collapse
Affiliation(s)
- H Iwama
- Hiroaki Iwama, DDS, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - R Ishii
- *Ryo Ishii, DDS, PhD, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - T Takamizawa
- Toshiki Takamizawa, DDS, PhD, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - R Aoki
- Ryota Aoki, DDS, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - S Watanabe
- Satoru Watanabe, DDS, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - K Hayashi
- Koji Hayashi, DDS, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - A Kamimoto
- Atsushi Kamimoto, DDS, Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, Tokyo, Japan
| | - M Miyazaki
- Masashi Miyazaki, DDS, Department of Operative Dentistry, Nihonihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
2
|
Takamizawa T, Aoki R, Hayashi K, Shoji M, Kasahara Y, Barkmeier WW, Latta MA, Kamimoto A, Miyazaki M. Scanning electron microscopy observation of dentin bond interfaces in different types of resin luting cements. Dent Mater J 2024; 43:179-190. [PMID: 38246629 DOI: 10.4012/dmj.2023-219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2024]
Abstract
This study aimed to observe and compare the resin luting cement (RLC)/dentin interfaces of different types of RLC systems with scanning electron microscopy (SEM). This study evaluated six self-adhesive resin luting cement systems (SARLCs), four systems combining a SARLC with a tooth primer (SARLCPs), and six conventional resin luting cement systems (CVRLCs). Cured resin composite rods were bonded to bovine dentin using RLCs in different etching modes. The morphological features at the interfaces were observed using SEM. Although all RLCs in etch-&-rinse (ER) mode showed a clear hybrid layer, most SARLCs had a thinner and more porous hybrid layer than the SARLCPs and CVRLCs. All SARLCPs with primer and CVRLCs showed a thin high-density layer below the primer layer in both etching modes. CVRLCs and SARLCPs with primer treatment systems may be more versatile and reliable when compared to simplified RLC systems.
Collapse
Affiliation(s)
| | - Ryota Aoki
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Kana Hayashi
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Mone Shoji
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Yuta Kasahara
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Wayne W Barkmeier
- Department of General Dentistry, Creighton University School of Dentistry
| | - Mark A Latta
- Department of General Dentistry, Creighton University School of Dentistry
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry
| |
Collapse
|
3
|
Watanabe S, Takamizawa T, Hayashi K, Aoki R, Barkmeier WW, Latta MA, Watanabe H, Miyazaki M. Comparing Various Resin Luting Cement Systems in Different Etching Modes Through Bond Durability and Morphological Features. Oper Dent 2024; 49:231-244. [PMID: 38349845 DOI: 10.2341/23-096-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/02/2023] [Indexed: 02/15/2024]
Abstract
OBJECTIVES This study aimed to investigate bond performance of various resin luting cement (RLC) systems on enamel and dentin in different etching modes and to compare the RLC-tooth interface morphology using scanning electron microscopy (SEM). METHODS AND MATERIALS The self-adhesive RLC systems used in combination with universal adhesives were as follows: Scotchbond Universal Adhesive Plus + RelyX Universal (3M Oral Care) and Clearfil Universal Bond Quick ER + SA Luting Multi (Kuraray Noritake Dental). These RLC systems were also used alone as self-adhesive RLC systems without universal adhesives (self-adhesive mode). The conventional RLC systems for comparison materials were as follows: BeautiBond Xtream + ResiCem EX (Shofu) and Tooth Primer + Panavia V5 (Kuraray Noritake Dental). Twelve specimens were prepared for each group to measure shear bond strength (SBS) in different etching modes. A stainless-steel rod was used as a substitute for indirect restorations. Bonded specimens were allocated to baseline (stored for 24 hours) and artificially aged (thermocycling [TC] for 10,000 cycles) groups. Representative treated tooth surfaces and RLC-tooth interfaces were observed using SEM. RESULTS Three-way analysis of variance (ANOVA) revealed that all the factors (etching mode, storage period, and RLC system) had a significant influence on the enamel SBS values (p<0.05). Enamel SBS was significantly higher in etch-&-rinse (ER) mode than in self-etch (SE) mode, regardless of RLC system or storage period. Three-way ANOVA showed that all the factors had a significant influence on the dentin SBS values (p<0.001). Most RLC systems showed significantly higher dentin SBS in SE mode than in ER mode, regardless of storage period. However, the combination with Scotchbond Universal Adhesive Plus and RelyX Universal showed no significant difference in SBS values between etching modes at the baseline and showed a significantly higher SBS value in ER mode than in SE mode after TC. CONCLUSIONS The self-adhesive RLC systems with universal adhesives tended to show higher enamel and dentin bond performance than the self-adhesive RLC systems alone. The morphology of treated tooth surfaces and resin cement-tooth interfaces were dependent on the RLC system and etching mode used. The RLC systems with primer application showed a thin, high-density layer above the intact dentin in both etching modes, suggesting chemical interaction.
Collapse
Affiliation(s)
- S Watanabe
- Satoru Watanabe, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - T Takamizawa
- *Toshiki Takamizawa, DDS, PhD, Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - K Hayashi
- Kana Hayashi, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - R Aoki
- Ryota Aoki, DDS, Department of Operative Dentistry, Nihon University Graduate School of Dentistry, Tokyo, Japan
| | - W W Barkmeier
- Wayne W. Barkmeier, DDS, MS, Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - M A Latta
- Mark A. Latta, DMD, MS, Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - H Watanabe
- Hidehiko Watanabe, DDS, MS, Department of Restorative Dentistry, Oregon Health & Science University, School of Dentistry, Portland, Oregon, USA
| | - M Miyazaki
- Masashi Miyazaki, DDS, PhD, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
4
|
De Almeida R, Siqueira F, Verde T, Ñaupari-Villasante R, Reis A, Loguercio AD, Cardenas A. Prolonged application time effects on universal adhesives in non-carious cervical lesions: An 18-month split mouth randomized clinical trial. J Dent 2024; 140:104800. [PMID: 38056759 DOI: 10.1016/j.jdent.2023.104800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/16/2023] [Accepted: 12/03/2023] [Indexed: 12/08/2023] Open
Abstract
OBJECTIVE This double-blind, split mouth randomized clinical trial aimed to assess the clinical performance of Clearfil Universal Bond Quick (CBUq) universal adhesive under different application times (no waiting and waiting) compared to Clearfil SE Bond adhesive in non-carious cervical lesions (NCCLs) over 18 months. METHODS One hundred and eighty-three restorations were distributed randomly into three groups based on the adhesive system and waiting time: CUBq without waiting time (CUBq-NW), CUBq with a 20 s waiting time (CUBq-W), and CSE with a 20 s waiting time. After placement, restorations were evaluated after 18 months using the International Dental Federation (FDI) and United States Public Health Service (USPHS) criteria. Statistical analyses involved Friedman repeated measures analysis of variance and Wilcoxon tests, with a significance level set at 5 %. RESULTS Over the 18-month period, no restorations were lost across the tested groups. Marginal adaptation evaluation indicated minor discrepancies in 21 restorations (8 CUBq-NW, 6 CUBq-W, and 7 CSE). There were no significant differences observed among the three groups following the 18-month clinical assessment (p > 0.05). Only two restorations showed marginal discoloration after 18 months (1 CUBq-NW and 1 CSE). CONCLUSIONS The application of Clearfil Universal Bond Quick using either the "waiting" or "no-waiting" technique exhibited excellent clinical results in NCCLs during the 18-month follow-up period, demonstrating comparable performance to Clearfil SE Bond in all assessed outcomes. CLINICAL SIGNIFICANCE The findings suggest that the new universal adhesive applied using the no-waiting technique demonstrates promising clinical performance when compared to conventional application methods. TRIAL REGISTRATION ClinicalTrials.gov identifer RBR-69p7mpr.
Collapse
Affiliation(s)
- Rab De Almeida
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Maranhão, Brazil
| | - Fsf Siqueira
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Maranhão, Brazil
| | - Thiago Verde
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Maranhão, Brazil
| | - R Ñaupari-Villasante
- Department of Restorative Dentistry, Dental Post-Graduate Program, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
| | - A Reis
- Department of Restorative Dentistry, Dental Post-Graduate Program, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil
| | - A D Loguercio
- Department of Restorative Dentistry, Dental Post-Graduate Program, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Paraná, Brazil.
| | - Afm Cardenas
- Department of Postgraduate Program in Dentistry, CEUMA University, São Luis, Maranhão, Brazil
| |
Collapse
|
5
|
Takamizawa T, Hirokane E, Sai K, Ishii R, Aoki R, Barkmeier WW, Latta MA, Miyazaki M. Bond durability of a two-step adhesive with a universal-adhesive-derived primer in different etching modes under different degradation conditions. Dent Mater J 2023; 42:121-132. [PMID: 36351598 DOI: 10.4012/dmj.2022-130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This study investigated the enamel and dentin bond durability of a two-step adhesive system, using a universal adhesive-derived primer (G2-Bond Universal [GU]), and compared it with the two conventional, two-step, self-etch adhesive systems (Clearfil SE Bond 2 [CS] and OptiBond XTR [OX]) under thermal cycling (TC) and long-term water storage (WS). The shear bond strengths to bovine enamel and dentin were determined using the etch-and-rinse and self-etch modes. Twelve specimens per test group were prepared and further divided into the following subgroups: 1) subjected to TC, 2) long-term WS, and 3) WS for 24 h (baseline). The enamel and dentin bond durability of GU was superior to those of CS and OX in different etching modes and under different degradation conditions. The latest two-step adhesive system, which utilizes universal adhesives' benefits in its primer, might offer durable clinical bonding performances and can be widely used in a clinical setting.
Collapse
Affiliation(s)
| | - Eizo Hirokane
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Keiichi Sai
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Ryota Aoki
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Wayne W Barkmeier
- Department of General Dentistry, Creighton University School of Dentistry
| | - Mark A Latta
- Department of General Dentistry, Creighton University School of Dentistry
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry
| |
Collapse
|
6
|
Effect of Different Application Modalities on the Bonding Performance of Adhesive Systems to Dentin: A Systematic Review and Meta-Analysis. Cells 2023; 12:cells12010190. [PMID: 36611983 PMCID: PMC9818277 DOI: 10.3390/cells12010190] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/11/2022] [Accepted: 12/30/2022] [Indexed: 01/05/2023] Open
Abstract
Diverse types of dental adhesives exhibit different cytotoxic outcomes on cells in vitro. Currently, no standard adhesive application technique has so far been decisive for clinicians for better durability of resin-dentin bonds of adhesive systems. The purpose of this study was to systematically review the literature to evaluate the bonding performance of adhesive systems to dentin by using different application modalities. The systematic research strategy was conducted by two reviewers among multiple databases: PubMed, Scopus, Web of Science, Embase, and Scielo. In vitro studies reporting the effects of additional steps for the application of adhesive systems on the bond strength to dentin were selected. Meta-analysis was performed using Review Manager Software version 5.3.5 using the random effects model. The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic review. The electronic research through different databases generated a total of 8318 references. After the examination of titles and abstracts, a total of 106 potentially relevant studies accessed the full-text evaluation phase. After full-text examination, 78 publications were included for the qualitative analysis, and 68 studies were included in the meta-analysis. Regarding the etch-and-rinse adhesive systems, the application modalities that improved the overall bond strength were the application of a hydrophobic resin layer (p = 0.005), an extended application time (p < 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p = 0.05), the agitation technique (p = 0.02), and the active application of the adhesive (p < 0.001). For self-etch adhesive systems, the techniques that improved the overall bond strength were the application of a hydrophobic resin layer (p < 0.001), an extended application time (p = 0.001), an application assisted by an electric current (p < 0.001), a double-layer application (p < 0.001), the agitation technique (p = 0.01), and the active application of the adhesive (p < 0.001). The in vitro evidence suggests that the application of adhesive systems using alternative techniques or additional strategies may be beneficial for improving their bond strength to dentin. The application modalities that favored the overall bond strength to dentin were an extended application time, a double-layer application, an application assisted by an electric current, the active application of the adhesive, and the application of a hydrophobic resin layer. Worth mentioning is that some techniques are intended to increase the degree of the conversion of the materials, and therefore, improvements in the biocompatibility of the materials can be expected.
Collapse
|
7
|
de Almeida RAM, Lima SNL, Nassif MV, Mattos NHR, de Matos TP, de Jesus Tavarez RR, Cardenas AFM, Bandeca MC, Loguercio AD. Eighteen-month clinical evaluation of a new universal adhesive applied in the "no-waiting" technique: a randomized clinical trial. Clin Oral Investig 2023; 27:151-163. [PMID: 36068369 PMCID: PMC9447982 DOI: 10.1007/s00784-022-04703-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 08/25/2022] [Indexed: 01/28/2023]
Abstract
OBJECTIVE The aim of this double-blind, randomized clinical trial was to evaluate the 6- and 18-month clinical performances of a new universal adhesive applied in the "no-waiting" (NW) technique to non-carious cervical lesions (NCCLs) using two evaluation criteria. MATERIALS AND METHODS One hundred and seventy-six restorations were assigned to four groups according to the adhesive system, adhesive strategy, and application mode: Prime&Bond Active (PB) applied using the etch-and-rinse (ER) and self-etch (SE) strategies with 20 s applications and Clearfil Universal Bond Quick (CQ) applied using the ER and SE strategies with the NW technique. The composite resin restorations were evaluated at baseline and after 6 and 18 months using the World Dental Federation (FDI) and US Public Health Service (USPHS) criteria. The Friedman repeated measures analysis of variance and Wilcoxon test were used for statistical analyses (α = 0.05). RESULTS No significant differences were observed among any of the groups or criteria after 6 months (p > 0.05). After 18 months, 10 restorations were lost (p > 0.05) (2 with PB-ER [95.5%; 95%CI: 92-100%], 4 with PB-SE [90.9%; 95%CI: 82-98%], 0 with CQ-ER [100%; 95%CI: 92-100%], and 4 with CQ-SE [90.9%; 82-98%]). The restorations performed with the SE strategy showed more marginal discrepancies than those performed with the ER strategy, mainly when the FDI criteria were used (p < 0.05). Those that used the PB-SE showed fewer marginal discrepancies than those that used the CQ-SE (FDI; p < 0.05). A few restorations showed marginal discrepancies after the USPHS analysis (p > 0.05). CONCLUSIONS The results when using the CQ-SE and -ER strategies with the NW technique were similar to those when using the PB-SE and -ER strategies in standard applications to non-carious cervical lesions after 6 and 18 months of clinical evaluation. CLINICAL RELEVANCE After 6 and 18 months, the application of Clearfil Universal Bond Quick with the "no-waiting" technique showed similar clinical performance compared to the standard application of Prime & Bond Active applied using the standard application time (20 s). TRIAL REGISTRATION ClinicalTrials.gov identifier RBR-5f9gps.
Collapse
Affiliation(s)
| | | | - Maria Vitória Nassif
- Department of Restorative Dentistry, School of Dentistry, Tuiuti University of Parana, Curitiba, Parana, Brazil
| | | | - Thalita Paris de Matos
- Department of Restorative Dentistry, School of Dentistry, Tuiuti University of Parana, Curitiba, Parana, Brazil
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil
| | | | | | - Matheus Coelho Bandeca
- Department of Postgraduate Program in Dentistry, CEUMA University, Sao Luis, Maranhao, Brazil
- Department of Restorative Dentistry, School of Dentistry, Tuiuti University of Parana, Curitiba, Parana, Brazil
| | - Alessandro D Loguercio
- Department of Restorative Dentistry, State University of Ponta Grossa, Rua Carlos Cavalcanti, 4748, Bloco M - Uvaranas, Ponta Grossa, Parana, Brazil.
| |
Collapse
|
8
|
Tang C, Ahmed MH, Yao C, Mercelis B, Yoshihara K, Peumans M, Van Meerbeek B. Experimental two-step universal adhesives bond durably in a challenging high C-factor cavity model. Dent Mater 2023; 39:70-85. [PMID: 36481302 DOI: 10.1016/j.dental.2022.11.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 11/20/2022] [Accepted: 11/25/2022] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To determine the bonding effectiveness of experimental 2-step universal adhesives (UAs) to high C-factor class-I cavity-bottom dentin and to assess the potential bond-strength contribution of an additional flowable composite layer. METHODS Three experimental 2-step UA formulations, involving the application of a 10-MDP-based primer followed by a hydrophobic adhesive resin with a 15-to-20-µm film thickness and differing only for filler, referred to as BZF-21 (silica and bioglass filler), BZF-29 (silica filler) and BZF-29_hv (higher silica-filler loading resulting in a higher viscosity), all prepared by GC, along with three representative commercial adhesives, Clearfil SE Bond 2 (C-SE2, Kuraray Noritake), G-Premio Bond (G-PrB, GC) and OptiBond FL (Opti-FL, Kerr), were comparatively investigated for their 'immediate' and 'aged' (50,000 thermocycles) micro-tensile bond strength (μTBS), when applied either in etch-and-rinse (E&R) or self-etch (SE) mode, to high C-factor class-I cavity-bottom dentin (n = 10; 10 experimental groups). Four additional experimental groups involved the extra application of the flowable composite G-ænial Universal Flo (GC), employed as an intermediate liner in combination with the adhesives BZF-29 and G-PrB and again applied both in E&R or SE mode. Statistical analysis was performed using linear mixed-effects (LME) modelling and linear regression analysis (p < 0.05). RESULTS All 2-step UAs performed similarly when compared to the gold-standard E&R Opti-FL and SE C-SE2 adhesives, except for the aged μTBS of BZF-29_hv applied in E&R mode, and significantly outperformed the 1-step UA G-PrB. Significant reduction in μTBS upon aging was only recorded for 2-step UAs applied in E&R mode. The extra flowable composite layer significantly improved G-PrB's μTBS. SIGNIFICANCE The experimental 2-step UAs revealed favorable bonding performance in the challenging high C-factor class-I cavity model, comparable to that of the multi-step gold-standard E&R and SE adhesives and superior to that of the 1-step UA investigated. An additionally applied flowable composite layer compensated for the lower bonding effectiveness of the 1-step UA in the high C-factor cavity model.
Collapse
Affiliation(s)
- Chuliang Tang
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium
| | - Mohammed H Ahmed
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium; Tanta University, Faculty of Dentistry, Department of Dental Biomaterials, Tanta 32511, Egypt
| | - Chenmin Yao
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium; Wuhan University, School & Hospital of Stomatology, The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, Wuhan 430079, China
| | - Ben Mercelis
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium
| | - Kumiko Yoshihara
- Okayama University, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Department of Pathology & Experimental Medicine, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8558, Japan; National Institute of Advanced Industrial Science and Technology (AIST), Health and Medical Research Institute, 2217-14 Hayashi-cho, Takamatsu, Kagawa 761-0395, Japan
| | - Marleen Peumans
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT - Biomaterials Research Group & UZ Leuven (University Hospitals Leuven), Dentistry, B-3000 Leuven, Belgium.
| |
Collapse
|
9
|
Strazzi-Sahyon HB, da Silva LMAV, Briso ALF, Dos Santos PH. In vitro study on how antioxidant solutions affect enamel surface characteristics and bonding interface of ceramic laminate veneers luting after dental bleaching. J Mech Behav Biomed Mater 2022; 133:105322. [PMID: 35724532 DOI: 10.1016/j.jmbbm.2022.105322] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 06/06/2022] [Accepted: 06/13/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE This in vitro study aimed to determine the effect of antioxidant solutions used after dental bleaching on the shear bond strength and adhesive interface sealing of ceramic laminate veneer luting. Additionally, effects on the enamel surface characteristics of hydrogen peroxide neutralization, surface energy, total free interaction energy, morphology, and chemical composition of enamel were assessed. MATERIAL AND METHODS Total 127 bovine incisors were divided into experimental groups, according to the surface treatment (unbleached and bleached enamel), antioxidant types (control; 10% ascorbic acid and 10% α-tocopherol), and periods of luting of ceramic laminates (24 h and after 14 days). Shear bond strength was assessed using microtensile test before and after thermal cycling (5760 cycles, 5-55 °C) (n = 6). The sealing of the adhesive interface was assessed using a confocal laser scanning microscope (n = 3). Hydrogen peroxide neutralization analysis was performed using a spectrophotometer (n = 5). The surface energy and total free interaction energy (n = 10) were measured using an automatic goniometer, while enamel morphology and chemical composition were assessed by scanning eletron microscopy (n = 3). Shear bond strength and enamel surface properties data were subjected to ANOVA followed by Tukey's test (α = 0.05). Adhesive interface micrographs were evaluated by the inter-examiner Kappa test and subjected to Kruskal-Wallis and Dunn's tests (α = 0.05). RESULTS In general, thermal aging decreased the shear bond strength values of the luting agents to enamel (P < .05). The α-tocopherol solution was able to reverse the oxidizing effect from dental bleaching, increasing the shear bond strength values and preserving the integrity of the adhesive interface sealing (P < .05). Moreover, the α-tocopherol antioxidant agent promoted higher hydrogen peroxide neutralization after dental bleaching (P < .05). Dental bleaching influenced the enamel surface, decreasing the surface energy and total free interaction energy values (P < .05). CONCLUSION α-tocopherol was able to reverse the oxidizing effects of dental bleaching, improving the enamel surface properties, as well as the adhesion and interface sealing of ceramic laminate veneer restorations.
Collapse
Affiliation(s)
- Henrico Badaoui Strazzi-Sahyon
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, SP, Brazil.
| | - Livia Maria Alves Valentim da Silva
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, SP, Brazil.
| | - André Luiz Fraga Briso
- Department of Preventive and Restorative Dentistry, Araçatuba School of Dentistry, Sao Paulo State University, UNESP, Araçatuba, SP, Brazil.
| | - Paulo Henrique Dos Santos
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, UNESP, Araçatuba, SP, Brazil.
| |
Collapse
|
10
|
Katsuki S, Takamizawa T, Yokoyama M, Sai K, Tamura T, Ishii R, Kamimoto A, Miyazaki M. Influence of bonding agent application method on the dentin bond durability of a two-step adhesive utilizing a universal-adhesive-derived primer. Eur J Oral Sci 2022; 130:e12868. [PMID: 35474469 DOI: 10.1111/eos.12868] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 03/25/2022] [Indexed: 11/28/2022]
Abstract
This study investigated the effect of the bonding agent application method on the dentin bond durability of a two-step adhesive utilizing a universal-adhesive-derived primer. The bonding durability of a universal adhesive was compared with those of two conventional two-step adhesives by shear bond strength testing after thermal cycling. The primer was applied (with or without phosphoric acid pre-etching), and the specimens were divided into three groups based on the bonding agent application method used as follows: (i) strong air-flow application, (ii) gentle air-flow application, and (iii) gentle air-flow + second bonding application. The shear bond strength was determined after thermal cycling. All the factors (bonding agent application method, adhesive system, and storage condition) significantly influenced the dentin shear bond strength both with and without phosphoric acid pre-etching. The specimens exposed to gentle air-flow showed a higher shear bond strength than did those exposed to strong air-flow and gentle air-flow + second bonding. The bond durability of the tested adhesive systems was influenced by the bonding agent application method, and this trend was material dependent. The G2-Bond Universal exhibited the same or greater dentin bond durability to the other two-step adhesive systems.
Collapse
Affiliation(s)
- Shun Katsuki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Munenori Yokoyama
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Keiichi Sai
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Tomohiko Tamura
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| | - Atsushi Kamimoto
- Department of Comprehensive Dentistry and Clinical Education, Nihon University School of Dentistry, Tokyo, Japan
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, Tokyo, Japan
| |
Collapse
|
11
|
Demirci M, Tuncer S, Tekçe N, Baydemir C. The effect of different application modes of a 1-step self-etch adhesive on the clinical performance of Class I composite restorations: A randomized controlled clinical trial. J ESTHET RESTOR DENT 2022; 34:1039-1050. [PMID: 35604035 DOI: 10.1111/jerd.12933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Revised: 05/01/2022] [Accepted: 05/02/2022] [Indexed: 11/30/2022]
Abstract
OBJECTIVE To evaluate the clinical performance of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendations, doubling the adhesive application time and layer in Class I cavities with a composite resin. MATERIALS AND METHODS A total of 39 patients aged between 14 and 43 (mean age: 19.1) years were enrolled in the study. Each patient received three restorations. In these three restorations, a 1-step self-etch adhesive was applied according to the manufacturer's recommendations (control group), by doubling the adhesive application time, and with double layers. The restorations were evaluated according to modified USPHS criteria at baseline, and 1, 2, 3, and 4-year recalls. RESULTS After 4 years, the success rate was 100% for restorations with the adhesive applied according to the manufacturers' recommendations, 96.9% for restorations applied by doubling the adhesive application time, and 93.8% for restorations applied with double adhesive layers. There was no significant difference between the three application methods among all the evaluation periods regarding the evaluation criteria. CONCLUSIONS The 4-year success rates of a 1-step self-etch dentin adhesive that was applied according to the manufacturers' recommendation, by doubling the adhesive application time, and with double layers were excellent. CLINICAL SIGNIFICANCE It is not recommended to double the adhesive application time nor apply a double layer of a 1-step self-etch adhesive because it does not improve the clinical performance of Class I composite restorations.
Collapse
Affiliation(s)
- Mustafa Demirci
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | - Safa Tuncer
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | - Neslihan Tekçe
- Department of Restorative Dentistry, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey
| | - Canan Baydemir
- Department of Biostatistics and Medical Informatics, Faculty of Medicine, Kocaeli University, Kocaeli, Turkey
| |
Collapse
|
12
|
Yilmaz F, Yazkan B, Herguner Siso S. Effects of different universal adhesives and surface treatments on repair bond strength between resin composites. J ESTHET RESTOR DENT 2022; 34:1068-1076. [PMID: 35578442 DOI: 10.1111/jerd.12915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Revised: 03/27/2022] [Accepted: 03/29/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVE This study aimed to evaluate the effects of different universal adhesives and surface treatments on the repair bond strength between resin composites. MATERIALS AND METHODS A total of 220 composite samples were divided into three groups according to the adhesive resin to be applied: 1) Scotchbond Universal, 2) G-Premio Bond, and 3) Peak Universal Bond. They were then divided into seven subgroups according to surface treatments (n = 10): A) air abrasion, B) air abrasion+silane, C) hydrofluoric acid, D) hydrofluoric acid+silane, E) air abrasion+hydrofluoric acid+silane, F) silane, and G) no surface treatment (negative control). After surface treatment, a repair composite was applied. Samples aged in the thermocycle were subjected to micro-tensile bond strength testing. Cohesive strength values of 10 non-aged composite blocks were used as a positive control. Kruskal-Wallis and one-way ANOVA tests were used for statistical evaluation. Fractured surfaces were evaluated using a scanning electron microscope. RESULTS In Scotchbond Universal and G-Premio Bond, the mean micro-tensile bond strength value of the no surface treatment subgroup was significantly lower than that of the positive control. All subgroups of Peak Universal Bond showed similar values to the positive control. CONCLUSION While Scotchbond Universal and G-Premio Bond required mechanical roughening before adhesive application, Peak Universal Bond did not require any surface treatment. CLINICAL SIGNIFICANCE Different universal adhesives may show different repair bonding strengths with different surface treatments. Since achieving a standard in this regard can be associated with many independent factors, clinicians should determine how to apply the adhesive they use most effectively with the most appropriate surface treatment based on their own clinical experience.
Collapse
Affiliation(s)
- Fatma Yilmaz
- Department of Restorative Dentistry, Faculty of Dentistry, Mugla Sitki Kocman University, Turkey
| | - Basak Yazkan
- Department of Restorative Dentistry, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Seyda Herguner Siso
- Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey
| |
Collapse
|
13
|
Lührs A, Brachmann C, Jacker‐Guhr S. Dentin contamination during repair procedures: A threat to universal adhesives? Clin Exp Dent Res 2022. [PMCID: PMC9209802 DOI: 10.1002/cre2.551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Objective This study examined the influence of surface contamination during repair procedures with hydrofluoric acid, silane, or ammonium polyfluoride on the bond strength of universal adhesives to dentin using different etching modes before and after thermocycling. Materials and Methods Dentin surfaces of human molars were contaminated in different ways (silane, hydrofluoric acid, ammonium polyfluoride, and no pretreatment as control) followed by application of a universal adhesive (etch & rinse or self‐etch mode). After a composite build‐up was placed onto each tooth, sticks for the microtensile bond strength (MTBS) test were sectioned. Half of the sticks were tested after water storage for 24 h, the other half after thermocycling (15,000 cycles, 5/55°C). The MTBS data were analyzed statistically by using the Kolmogorov–Smirnov test, one‐way analysis of variance, and Tukey HSD test (p < 0.05). The fracture patterns of all specimens were evaluated and analyzed using a χ2 test. Results Dentin contamination with a multifunctional silane does not influence microtensile bond strength irrespective of aging. Contamination with hydrofluoric acid or an ammonium polyfluoride primer leads to a significantly lower bond strength after aging, irrespective of the etch mode. Conclusion Dentin contamination with hydrofluoric acid or ammonium polyfluorides during repair procedures should be avoided, as they appear to decrease the bond strength of universal adhesives.
Collapse
Affiliation(s)
- Anne‐Katrin Lührs
- Department of Conservative Dentistry, Periodontology and Preventive Dentistry Hannover Medical School Hannover Germany
| | - Cosima Brachmann
- Department of Prosthetic Dentistry and Biomedical Materials Research Hannover Medical School Hannover Germany
| | - Silke Jacker‐Guhr
- Department of Conservative Dentistry, Periodontology and Preventive Dentistry Hannover Medical School Hannover Germany
| |
Collapse
|
14
|
Yazici AR, Uslu Tekce A, Kutuk ZB. Comparative evaluation of different adhesive strategies of a universal adhesive in class II bulk-fill restorations: A 48-month randomized controlled trial. J Dent 2021; 117:103921. [PMID: 34896442 DOI: 10.1016/j.jdent.2021.103921] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 12/05/2021] [Accepted: 12/07/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To compare the clinical performance of the universal adhesive used in etch-and-rinse (ER) and self-etch (SE) adhesive strategies for 48-month in class II bulk-fill restorations. METHODS A total of 84 class II bulk-fill resin composite (Tetric EvoCeram Bulk Fill) restorations were placed in 35 participants by one operator using the universal adhesive's (Adhese Universal VivaPen) etch-and-rinse or self-etch mode randomly. The restorations were evaluated by two calibrated examiners at baseline and after 6-, 12-, 24-, 36- and 48-month using modified USPHS criteria. The comparison of the two adhesive strategies for each evaluation criteria was performed with the chi-square test. The baseline scores were compared with those at the recalls using the Friedman and Cochran's Q-test (p < .05). RESULTS At 48-month, 74 restorations were evaluated in 30 participants (recall rate: 85.7%). Marginal discoloration was statistically more frequent in SE approach (p < .05), whereas no significant difference was observed between the two strategies in terms of marginal adaptation (p > .05). There were statistically significant differences between the baseline and 48-month recall in the SE group in terms of marginal adaptation and discoloration (p < .05). In ER group, significant differences were found between baseline and 48-month only for marginal adaptation (p < .05). None of the restorations showed post-operative sensitivity. Secondary caries was observed in one restoration from SE group. CONCLUSIONS The tested bulk-fill restorative exhibited better clinical performance only in terms of marginal discoloration when the universal adhesive was used with ER strategy. CLINICAL RELEVANCE Though ER approach of the tested universal adhesive appears to be advantageous in terms of marginal discoloration, both adhesive strategies had similar impact on the clinical success of bulk-fill resin restorations.
Collapse
Affiliation(s)
- Ayse Ruya Yazici
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Aybuke Uslu Tekce
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Zeynep Bilge Kutuk
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey.
| |
Collapse
|
15
|
Fehrenbach J, Isolan CP, Münchow EA. Is the presence of 10-MDP associated to higher bonding performance for self-etching adhesive systems? A meta-analysis of in vitro studies. Dent Mater 2021; 37:1463-1485. [PMID: 34456050 DOI: 10.1016/j.dental.2021.08.014] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/16/2021] [Accepted: 08/17/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The purpose of this systematic review and meta-analysis was to analyze the literature on the bond strength of self-etching (SE) adhesives containing 10-MDP or other acidic functional monomers, comparing the bonding performance of both compositions. METHODS This study is registered in PROSPERO (CRD42020175715) and it followed the PRISMA Statement. The literature search was performed in PubMed, Web of Science, SciELO, Scopus, LILACS, IBECS, and BBO from the starting coverage date through 30 June 2021. Study eligibility criteria consisted of in vitro studies that evaluated the bond strength (microtensile, microshear, tensile or shear testing) to sound dentin/enamel of a minimum of two distinct SE systems, with at least one material containing 10-MDP and one other being comprised of a distinct acidic composition. Statistical analyses were carried out with RevMan 5.3.5 and using random-effects models with the significance level at p < 0.05. Also, Bayesian network meta-analysis (NMA) was conducted using MetaInsight V3 tool. RESULTS From 740 relevant studies evaluated in full-text analysis, 210 were incorporated to the systematic review and 206 in meta-analysis. The majority of studies was classified as having medium risk of bias (56.7%), followed by low (35.2%) and high (8.1%) risk of bias. Data from a total of 64 adhesive systems were collected, which favored the 10-MDP-based group at both dentin (overall effect: 6.98; 95% CI: 5.61, 8.36; p < 0.00001) and enamel (overall effect: 2.79; 95% CI: 1.62, 3.96; p < 0.00001) substrates. Microtensile testing was more frequently used (73.4%) in the included studies. Adhesives based on 10-MDP showed greater bonding performance than adhesives comprised of monomers such as PENTA, 6-MHP, 4-META, 4-MET, pyrophosphate esters, mixed composition or monomers derived from sulfonic acid (p ≤ 0.01); whereas similar bond strength values were verified between 10-MDP-based materials and those containing PEM-F, acrylamide phosphates, 4-AET, MAC-10, or monomers derived from polyacrylic and phosphonic acids (p ≥ 0.05). Adhesives based on GPDM were the only ones that resulted in greater bonding potential than the 10-MDP-based group (p = 0.03). Dental bonds in dentin were favored with the application of 2-step 10-MDP-based adhesives; whereas in enamel the dental bonds were favored for both 2-steps versions of adhesives, regardless of the presence of 10-MDP. Indirect evidence from NMA revealed that 1-step 10-MDP-free and universal 10-MDP-free adhesives seemed to perform worst in dentin and enamel, respectively. SIGNIFICANCE Adhesives containing 10-MDP showed higher bonding performance than materials formulated with other acidic ingredients, although this result relied on the type of mechanical testing, type of the substrate, acidic composition of the adhesive, and the application category of the SE system. This review summarized the effects of the foregoing factors on the adhesion to dental substrates.
Collapse
Affiliation(s)
- Julia Fehrenbach
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil.
| | - Cristina Pereira Isolan
- Department of Restorative Dentistry, School of Dentistry, Federal University of Jequitinhonha and Mucuri Valleys, Rua da Glória, 187, Centro, Diamantina, Brazil.
| | - Eliseu Aldrighi Münchow
- Graduate Program in Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Santa Cecília, Porto Alegre, Brazil; Department of Conservative Dentistry, School of Dentistry, Federal University of Rio Grande do Sul, Rua Ramiro Barcelos, 2492, Porto Alegre, Brazil.
| |
Collapse
|
16
|
Bonding Performance of Universal Adhesives Applied to Nano-Hydroxyapatite Desensitized Dentin Using Etch-and-Rinse or Self-Etch Mode. MATERIALS 2021; 14:ma14164746. [PMID: 34443268 PMCID: PMC8398634 DOI: 10.3390/ma14164746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 08/12/2021] [Accepted: 08/20/2021] [Indexed: 11/16/2022]
Abstract
The study assessed the bonding performance of three universal adhesives on desensitized dentin with etch-and-rinse mode or self-etch mode after nano-hydroxyapatite (nHAp)-based desensitizers application. Simulated sensitive dentin specimens were prepared and separated into four groups: no treatment as the negative control, groups desensitized by Biorepair toothpaste, Dontodent toothpaste, or nHAp paste. Three universal adhesives of All-Bond Universal, Single Bond Universal, and Clearfil Universal Bond with etch-and-rinse or self-etch mode were bonded to the desensitized dentin specimens separately, followed by resin composite build-ups. Micro-tensile bond strength was measured using a micro-tensile tester. The wettability of desensitized dentin was evaluated by the contact angle of the adhesives. Resin infiltration was observed by confocal laser scanning microscopy. Dentin tubular occlusion and nanoleakage were observed by scanning electron microscope. The results showed that the etch-and-rinse or self-etch mode of each adhesive showed similar bond strength when bonding to nHAp-based desensitized dentin. The dentin surface was partially covered by desensitizers after desensitization. Compared with the self-etch mode, stronger demineralization and more reopened dentin tubules were observed in the etch-and-rinse mode after acid etching; longer resin tags and more nanoleakage in the resin-dentin interface were observed when using the etch-and-rinse mode. When bonding to nHAp-based desensitized dentin with universal adhesives, no significant difference in bond strength was found between self-etch mode or etch-and-rinse mode; while the latter produced more nanoleakage in the resin-dentin interfaces.
Collapse
|
17
|
Mizutani K, Takamizawa T, Ishii R, Shibasaki S, Kurokawa H, Suzuki M, Tsujimoto A, Miyazaki M. Flexural Properties and Polished Surface Characteristics of a Structural Colored Resin Composite. Oper Dent 2021; 46:E117-E131. [PMID: 34370032 DOI: 10.2341/20-154-l] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/13/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The aim of this study was to determine the flexural properties and surface characteristics of a structural colored resin composite after different finishing and polishing methods, in comparison to those of conventional resin composites. METHODS AND MATERIALS A structural color resin composite, Omnichroma (OM, Tokuyama Corp, Chiyoda City, Tokyo, Japan), and two comparison resin composites, Filtek Supreme Ultra (FS, 3M, St Paul, MN, USA) and Tetric EvoCeram (TE, Ivoclar Vivadent, Schaan, Liechtenstein), were used. The flexural properties of the resin composites were determined in accordance with the ISO 4049 specifications. For surface properties, 70 polymerized specimens of each resin composite were prepared and divided into seven groups of 10. Surface roughness (Sa), gloss (GU), and surface free energy (SFE) were investigated after the following finishing and polishing methods. Three groups of specimens were finished with a superfine-grit diamond bur (SFD), and three with a tungsten carbide bur (TCB). After finishing, one of the two remaining groups was polished with a one-step silicone point (CMP), and the other with an aluminum oxide flexible disk (SSD). A group ground with SiC 320-grit was set as a baseline. RESULTS The average flexural strength ranged from 116.6 to 142.3 MPa in the following order with significant differences between each value: FS > TE > OM. The average E ranged from 6.8 to 13.2 GPa in the following order with significant differences between each value: FS > TE > OM. The average R ranged from 0.77 to 1.01 MJ/mm3 in the following order: OM > FS > TE. The Sa values of the OM groups polished with CMP and SSD were found to be significantly lower than those of the other resin composites, regardless of the finishing method. The GU values appeared to be dependent on the material and the finishing method used. The OM specimens polished with SSD showed significantly higher GU values than those polished with CMP. Most of the resin composites polished with SSD demonstrated significantly higher γS values compared to the other groups. Extremely strong negative correlations between Sa and GU in the combined data from the three resin composites and each resin composite and between Sa and γS in the OM specimens were observed; GU showed a strong positive correlation with γS in the same material. CONCLUSION These findings indicate that both flexural and surface properties are material dependent. Furthermore, the different finishing and polishing methods used in this study were observed to affect the Sa, GU, and SFE of the resin composites.
Collapse
|
18
|
Girotto AC, Abuna G, Sanchez-Puetate C, Piccioni MA, Porto TS, Kuga MC. Effect of different adhesive strategies and storage time on bond strength of bifunctional monomers to simulated endodontically-treated dentin. Dent Mater J 2021; 40:1410-1417. [PMID: 34321370 DOI: 10.4012/dmj.2021-074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Adhesive strategies were evaluated on the bond strength of bi-functional monomers bonded to endodontically-treated-dentin (ETD). Superficial dentin was removed on human molars. Teeth were immersed in 5 mL 2.5% NaOCl, followed by immersion in 5 mL 17% EDTA. Dentin surface impregnated with epoxy resin-based sealer was then divided four groups (n=10): Scotchbond Multi-Purpose (SBMP); Single Bond Universal (SBU); Optibond All-in-One (OPB); and Tetric-N-Bond Universal (TBU). After 24-h or 1-year-of-storage specimens were submitted to microtensile bond strength (µTBS) and failure classification. A confocal laser scanning microscope (CLSM) evaluated the hybrid layer formation. Two-way ANOVA and Tukey-HSD test were performed (α=5%). The µTBS did not present statistical differences among adhesive strategies after 24-h. Significant differences were found after 1-year-of-storage. CLSM analysis showed water infiltration and consequently degradation of the hybrid layer after 1-year-of-storage. The use of SBU universal adhesive on the self-etching mode on ETD produced more stable bond over the 1-year-of-storage.
Collapse
Affiliation(s)
- Aline Carvalho Girotto
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP)
| | - Gabriel Abuna
- Department of General Dentistry, School of Dental Medicine, East Carolina University
| | | | - Mayra Andressa Piccioni
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP)
| | - Thiago Soares Porto
- Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University
| | - Milton Carlos Kuga
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University (UNESP)
| |
Collapse
|
19
|
Deniz ST, Oglakci B, Yesilirmak SO, Dalkilic EE. The effect of immediate dentin sealing with chlorhexidine pretreatment on the shear bond strength of dual-cure adhesive cement. Microsc Res Tech 2021; 84:3204-3210. [PMID: 34286901 DOI: 10.1002/jemt.23878] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/27/2021] [Accepted: 07/06/2021] [Indexed: 11/07/2022]
Abstract
The purpose of this in vitro study was to evaluate the effect of immediate dentin sealing (IDS) with and without chlorhexidine (CHX) pretreatment on the shear bond strength (SBS) of dual-cure adhesive resin cement. Mid-coronal dentin surfaces were obtained from 75 human molars. They were randomly allocated into five groups in accordance to type of IDS [etch&rinse/ER (Adper Single Bond2) and universal/U adhesive systems (Single Bond Universal)] and presence of CHX application (n = 15): Group ER; Group ER + CHX; Group U; Group U + CHX; and Group C (no IDS). Dual-cure adhesive resin cements were bonded with a cylinder-shaped Teflon mold. The SBS was measured using a universal test machine. Fracture type was evaluated with stereomicroscope. The resin/dentin interfaces were examined with an environmental scanning electron microscope. Data were statistically analyzed with two-way analysis of variance and Bonferroni tests (p < .05). Regarding the IDS treatment groups with/without CHX, there were no significant differences in SBS (p > .05). Group U + CHX showed significantly higher SBS than Group C (p < .05). Regarding the presence of CHX, no significant differences in SBS were found (p > .05). The prevalent failure mode was the mixed type for most of the groups. Group C exhibited an intact and regular hybrid layer with no resin tag, whereas longer and clear resin-tag formation was visible for Group U + CHX. CHX pretreatment improved the bond strength between adhesive resin cement and dentin when IDS treatment was performed with a universal adhesive system.
Collapse
Affiliation(s)
- Sule Tugba Deniz
- Faculty of Dentistry, Department of Prosthodontics, Bezmialem Vakif University, Istanbul, Turkey
| | - Burcu Oglakci
- Faculty of Dentistry, Department of Restorative Dentistry, Bezmialem Vakif University, Istanbul, Turkey
| | - Sevda Ozturk Yesilirmak
- Faculty of Dentistry, Department of Restorative Dentistry, Istanbul Yeni Yuzyil University, Istanbul, Turkey
| | | |
Collapse
|
20
|
Hardan L, Bourgi R, Kharouf N, Mancino D, Zarow M, Jakubowicz N, Haikel Y, Cuevas-Suárez CE. Bond Strength of Universal Adhesives to Dentin: A Systematic Review and Meta-Analysis. Polymers (Basel) 2021; 13:814. [PMID: 33799923 PMCID: PMC7961712 DOI: 10.3390/polym13050814] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Revised: 03/03/2021] [Accepted: 03/04/2021] [Indexed: 02/07/2023] Open
Abstract
Currently, the availability of a wide variety of universal adhesives makes it difficult for clinicians to choose the correct system for specific bonding situations to dentin substrate. This study aimed to determine whether there are any alternative techniques or additional strategies available to enhance the bond strength of universal adhesives to dentin through a systematic review and meta-analysis. Two reviewers executed a literature search up to September 2020 in four electronic databases: PubMed, ISI Web of Science, Scopus, and EMBASE. Only in vitro studies that reported the dentin bond strength of universal adhesives using additional strategies were included. An analysis was carried out using Review Manager Software version 5.3.5 (The Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The methodological quality of each in vitro study was assessed according to the parameters of a previous systematic. A total of 5671 potentially relevant studies were identified. After title and abstract examination, 74 studies remained in systematic review. From these, a total of 61 studies were included in the meta-analysis. The bond strength of universal adhesives to dentin was improved by the use of one of the following techniques: Previous application of matrix metalloproteinases (MMP) inhibitors (p < 0.001), prolonged application time (p = 0.007), scrubbing technique (p < 0.001), selective dentin etching (p < 0.001), non-atmospheric plasma (p = 0.01), ethanol-wet bonding (p < 0.01), prolonged blowing time (p = 0.02), multiple layer application (p = 0.005), prolonged curing time (p = 0.006), and hydrophobic layer coating (p < 0.001). On the other hand, the use of a shortened application time (p = 0.006), and dentin desensitizers (p = 0.01) impaired the bond strength of universal adhesives to dentin. Most of the analyses performed showed a high heterogenicity. The in vitro evidence suggests that the application of universal adhesives using some alternative techniques or additional strategies may be beneficial for improving their bonding performance to dentin. This research received no external funding. Considering that this systematic review was carried out only with in vitro studies, registration was not performed.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, 1107 2180 Beirut, Lebanon; (L.H.); (R.B.)
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, 1107 2180 Beirut, Lebanon; (L.H.); (R.B.)
| | - Naji Kharouf
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France
| | - Davide Mancino
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
- Department of Endodontics, Faculty of Dental Medicine, Strasbourg University, 67000 Strasbourg, France
| | - Maciej Zarow
- Private Practice, “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, pl. Inwalidow 7/5, 30-033 Cracow, Poland; (M.Z.); (N.J.)
| | - Natalia Jakubowicz
- Private Practice, “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, pl. Inwalidow 7/5, 30-033 Cracow, Poland; (M.Z.); (N.J.)
| | - Youssef Haikel
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France; (D.M.); (Y.H.)
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca, Hidalgo 42160, Mexico
| |
Collapse
|
21
|
Burrer P, Dang H, Par M, Attin T, Tauböck TT. Effect of Over-Etching and Prolonged Application Time of a Universal Adhesive on Dentin Bond Strength. Polymers (Basel) 2020; 12:E2902. [PMID: 33287394 PMCID: PMC7761786 DOI: 10.3390/polym12122902] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 12/01/2020] [Accepted: 12/02/2020] [Indexed: 11/28/2022] Open
Abstract
This study investigated the effect of over-etching and prolonged application time of a universal adhesive on dentin bond strength. Ninety extracted human molars were ground to dentin and randomly allocated into nine groups (G1-9; n = 10 per group), according to the following acid etching and adhesive application times. In the control group (G1), phosphoric acid etching was performed for 15 s followed by application of the universal adhesive Scotchbond Universal (3M) for 20 s, as per manufacturer's instructions. In groups G2-5, both the etching and adhesive application times were either halved, doubled, quadrupled, or increased eightfold. In groups G6-9, etching times remained the same as in G2-5 (7.5 s, 30 s, 60 s, and 120 s, respectively), but the adhesive application time was set at 20 s as in the control group (G1). Specimens were then restored with a nanofilled composite material and subjected to microtensile bond strength testing. Bond strength data were statistically analyzed by ANOVA and Tukey's post-hoc tests (α = 0.05). The relationship of bond strength with etching and adhesive application time was examined using linear regression analysis. Treatment of dentin with halved phosphoric acid etching and adhesive application times (G2) resulted in a significant bond strength decrease compared to the control group (G1) and all other test groups, including the group with halved acid etching, but 20 s of adhesive application time (G6). No significant differences in bond strength were found for groups with multiplied etching times and an adhesive application time of 20 s or more, when compared to the control group (G1). In conclusion, a universal adhesive application time of at least 20 s is recommended when bonding to over-etched dentin.
Collapse
Affiliation(s)
- Phoebe Burrer
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (H.D.); (T.A.); (T.T.T.)
| | - Hoang Dang
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (H.D.); (T.A.); (T.T.T.)
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia;
| | - Thomas Attin
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (H.D.); (T.A.); (T.T.T.)
| | - Tobias T. Tauböck
- Clinic of Conservative and Preventive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland; (H.D.); (T.A.); (T.T.T.)
| |
Collapse
|
22
|
Soto-Montero J, Nima G, Dias CTS, Price RBT, Giannini M. Influence of beam homogenization on bond strength of adhesives to dentin. Dent Mater 2020; 37:e47-e58. [PMID: 33143939 DOI: 10.1016/j.dental.2020.10.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/17/2020] [Accepted: 10/06/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE This study evaluated the effect of beam homogeneity on the microtensile bond strength (μTBS) of two adhesive resins to dentin. METHODS One polywave light-emitting-diode (LED) LCU (Bluephase Style, Ivoclar Vivadent AG) was used with two different light guides: a regular tip (RT, 1010 mW/cm2 emittance) and a homogenizer tip (HT, 946 mW/cm2 emittance). The emission spectra and beam profiles were measured from both light guides. Extracted third molars were prepared for μTBS evaluation using two adhesive systems: Excite F (EXF) and Adhese Universal (ADU). Bond strength was calculated for each specimen (n = 10) at locations that correlated with the output of the two LED chips emitting blue (455 nm) and the one chip that emitted violet light (409 nm) after 24-hs and after one-year water-storage. The μTBS was analyzed using a four-way analysis of variance (factors: adhesive system, light guide, LED wavelength, and storage time) and post-hoc Tukey test (α = 0.05). RESULTS EXF always delivered a higher μTBS than ADU (p < 0.0001), with the μTBS of ADU being about 20% lower than EXF. The light guide (p = 0.0259) and storage time (p = 0.0009) significantly influenced the μTBS. The LED wavelengths had no influence on the μTBS (p > 0.05). SIGNIFICANCE Homogeneity of the emitted light beam was associated with higher 24-h μTBS to dentin, regardless of the adhesive tested. Also, differences in the composition of adhesives can affect their compatibility with restorative composites and their ability to maintain bonding over one year.
Collapse
Affiliation(s)
- Jorge Soto-Montero
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Avenida Limeira 901, 13414-903 Piracicaba, SP, Brazil; Department of Restorative Dentistry, Faculty of Dentistry, University of Costa Rica, Instalaciones Deportivas, 11501-2060, Montes de Oca, San José, Costa Rica.
| | - Gabriel Nima
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Avenida Limeira 901, 13414-903 Piracicaba, SP, Brazil.
| | - Carlos T S Dias
- Department of Statistical Mathematics, Luiz de Queiroz Higher School of Agriculture, University of São Paulo, Avenida Pádua Dias 11, 13418-900 Piracicaba, SP, Brazil.
| | - Richard B T Price
- Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University. 5981 University Avenue, 15000, Halifax, NS, Canada.
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, Avenida Limeira 901, 13414-903 Piracicaba, SP, Brazil.
| |
Collapse
|
23
|
HIDARI T, TAKAMIZAWA T, IMAI A, HIROKANE E, ISHII R, TSUJIMOTO A, SUZUKI T, MIYAZAKI M. Role of the functional monomer 10-methacryloyloxydecyl dihydrogen phosphate in dentin bond durability of universal adhesives in etch-&-rinse mode. Dent Mater J 2020; 39:616-623. [DOI: 10.4012/dmj.2019-154] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Toshie HIDARI
- Department of Operative Dentistry, Nihon University School of Dentistry
| | | | - Arisa IMAI
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Eizo HIROKANE
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Ryo ISHII
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Akimasa TSUJIMOTO
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Takayuki SUZUKI
- Department of Operative Dentistry, Nihon University School of Dentistry
| | - Masashi MIYAZAKI
- Department of Operative Dentistry, Nihon University School of Dentistry
| |
Collapse
|
24
|
Hirokane E, Takamizawa T, Kasahara Y, Ishii R, Tsujimoto A, Barkmeier WW, Latta MA, Miyazaki M. Effect of double-layer application on the early enamel bond strength of universal adhesives. Clin Oral Investig 2020; 25:907-921. [PMID: 32474808 DOI: 10.1007/s00784-020-03379-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 05/25/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES The present study aimed to investigate the changes in the enamel bond strengths of universal adhesives in the early phase of specimen creation and evaluate the effect of double-layer application on enamel bond effectiveness using different etching modes. METHOD Four universal adhesives, namely Clearfil Universal Bond Quick, G-Premio Bond, Scotchbond Universal, and Tokuyama Universal Bond, were used. Clearfil SE Bond two-step self-etch adhesive system was used as a comparison. Fifteen specimens per group were used for determining the shear bond strength (SBS) to bovine enamel in the etch-and-rinse or self-etch mode. The adhesive was applied to specimens in accordance with the manufacturers' instructions (single-layer application), or the adhesive was applied twice (double-layer application). The bonded specimens were stored in distilled water at 37 °C for 5 min or 1, 6, 12, or 24 h before SBS testing. The flexural properties of the resin composite Clearfil AP-X were measured for the same storage periods. RESULTS All universal adhesives exhibited increased SBS values with prolonged storage periods regardless of the application technique or etching mode used. Double-layer application was associated with higher SBS values than single-layer application for most universal adhesives over the same storage period. CONCLUSION Phosphoric acid pre-etching and double-layer application of universal adhesives resulted in increased enamel bond strength in the early phase of specimen bonding. CLINICAL RELEVANCE Care should be taken when using universal adhesives in the self-etch mode for enamel bonding because the enamel adhesion is sensitive to the duration after filling.
Collapse
Affiliation(s)
- Eizo Hirokane
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Toshiki Takamizawa
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan.
| | - Yuta Kasahara
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Ryo Ishii
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Akimasa Tsujimoto
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| | - Wayne W Barkmeier
- Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - Mark A Latta
- Department of General Dentistry, Creighton University School of Dentistry, Omaha, NE, USA
| | - Masashi Miyazaki
- Department of Operative Dentistry, Nihon University School of Dentistry, 1-8-13, Kanda-Surugadai, Chiyoda-ku, Tokyo, 101-8310, Japan
| |
Collapse
|