1
|
Out-of-field organ doses and associated risk of cancer development following radiation therapy with photons. Phys Med 2021; 90:73-82. [PMID: 34563834 DOI: 10.1016/j.ejmp.2021.09.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 09/06/2021] [Accepted: 09/13/2021] [Indexed: 11/21/2022] Open
Abstract
Innovations in cancer treatment have contributed to the improved survival rate of these patients. Radiotherapy is one of the main options for cancer management nowadays. High doses of ionizing radiation are usually delivered to the tumor site with high energy photon beams. However, the therapeutic radiation exposure may lead to second cancer induction. Moreover, the introduction of intensity-modulated radiation therapy over the last decades has increased the radiation dose to out-of-field organs compared to that from conventional irradiation. The increased organ doses might result in elevated probabilities for developing secondary malignancies to critical organs outside the treatment volume. The organ-specific dosimetry is considered necessary for the theoretical second cancer risk assessment and the proper analysis of data derived from epidemiological reports. This study reviews the methods employed for the measurement and calculation of out-of-field organ doses from exposure to photons and/or neutrons. The strengths and weaknesses of these dosimetric approaches are described in detail. This is followed by a review of the epidemiological data associated with out-of-field cancer risks. Previously published theoretical cancer risk estimates for adult and pediatric patients undergoing radiotherapy with conventional and advanced techniques are presented. The methodology for the theoretical prediction of the probability of carcinogenesis to out-of-field sites and the limitations of this approach are discussed. The article also focuses on the factors affecting the magnitude of the probability for developing radiotherapy-induced malignancies. The restriction of out-of-field doses and risks through the use of different types of shielding equipment is presented.
Collapse
|
2
|
Niroomand‐Rad A, Chiu‐Tsao S, Grams MP, Lewis DF, Soares CG, Van Battum LJ, Das IJ, Trichter S, Kissick MW, Massillon‐JL G, Alvarez PE, Chan MF. Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55. Med Phys 2020; 47:5986-6025. [DOI: 10.1002/mp.14497] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 09/15/2020] [Accepted: 09/17/2020] [Indexed: 12/12/2022] Open
Affiliation(s)
| | | | | | | | | | | | - Indra J. Das
- Radiation Oncology Northwestern University Memorial Hospital Chicago IL USA
| | - Samuel Trichter
- New York‐Presbyterian HospitalWeill Cornell Medical Center New York NY USA
| | | | - Guerda Massillon‐JL
- Instituto de Fisica Universidad Nacional Autonoma de Mexico Mexico City Mexico
| | - Paola E. Alvarez
- Imaging and Radiation Oncology Core MD Anderson Cancer Center Houston TX USA
| | - Maria F. Chan
- Memorial Sloan Kettering Cancer Center Basking Ridge NJ USA
| |
Collapse
|
3
|
Miften M, Mihailidis D, Kry SF, Reft C, Esquivel C, Farr J, Followill D, Hurkmans C, Liu A, Gayou O, Gossman M, Mahesh M, Popple R, Prisciandaro J, Wilkinson J. Management of radiotherapy patients with implanted cardiac pacemakers and defibrillators: A Report of the AAPM TG-203 †. Med Phys 2019; 46:e757-e788. [PMID: 31571229 DOI: 10.1002/mp.13838] [Citation(s) in RCA: 71] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 07/16/2019] [Accepted: 08/28/2019] [Indexed: 11/11/2022] Open
Abstract
Managing radiotherapy patients with implanted cardiac devices (implantable cardiac pacemakers and implantable cardioverter-defibrillators) has been a great practical and procedural challenge in radiation oncology practice. Since the publication of the AAPM TG-34 in 1994, large bodies of literature and case reports have been published about different kinds of radiation effects on modern technology implantable cardiac devices and patient management before, during, and after radiotherapy. This task group report provides the framework that analyzes the potential failure modes of these devices and lays out the methodology for patient management in a comprehensive and concise way, in every step of the entire radiotherapy process.
Collapse
Affiliation(s)
- Moyed Miften
- Task Group 203, Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, 80045, USA
| | - Dimitris Mihailidis
- Task Group 203, University of Pennsylvania, Perelman Center for Advanced Medicine, Philadelphia, PA, 19104, USA
| | - Stephen F Kry
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Chester Reft
- Department of Radiation Oncology, University of Chicago, Chicago, IL, 60637, USA
| | - Carlos Esquivel
- Department of Radiation Oncology, UT Health Sciences Center, San Antonio, TX, 78229, USA
| | - Jonathan Farr
- Division of Radiological Sciences, St. Jude Children's Research Hospital, Memphis, TN, 38105, USA
| | - David Followill
- Department of Radiation Physics, UT MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Coen Hurkmans
- Department of Radiotherapy, Catharina Hospital, Eindhoven, the Netherlands
| | - Arthur Liu
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO, 80045, USA
| | - Olivier Gayou
- Department of Radiation Oncology, Allegheny General Hospital, Pittsburg, PA, 15212, USA
| | - Michael Gossman
- Department of Radiation Oncology, Tri-State Regional Cancer Center, Ashland, KY, 41101, USA
| | - Mahadevappa Mahesh
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD, 21287, USA
| | - Richard Popple
- Department of Radiation Oncology, University of Alabama, Birmingham, AL, 35249, USA
| | - Joann Prisciandaro
- Department of Radiation Oncology, University of Michigan, Ann Arbor, MI, 48109, USA
| | | |
Collapse
|
4
|
Kry SF, Bednarz B, Howell RM, Dauer L, Followill D, Klein E, Paganetti H, Wang B, Wuu CS, George Xu X. AAPM TG 158: Measurement and calculation of doses outside the treated volume from external-beam radiation therapy. Med Phys 2017; 44:e391-e429. [DOI: 10.1002/mp.12462] [Citation(s) in RCA: 164] [Impact Index Per Article: 23.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 05/17/2017] [Accepted: 05/25/2017] [Indexed: 12/14/2022] Open
Affiliation(s)
- Stephen F. Kry
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Bryan Bednarz
- Department of Medical Physics; University of Wisconsin; Madison WI 53705 USA
| | - Rebecca M. Howell
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Larry Dauer
- Departments of Medical Physics/Radiology; Memorial Sloan-Kettering Cancer Center; New York NY 10065 USA
| | - David Followill
- Department of Radiation Physics; MD Anderson Cancer Center; Houston TX 77054 USA
| | - Eric Klein
- Department of Radiation Oncology; Washington University; Saint Louis MO 63110 USA
| | - Harald Paganetti
- Department of Radiation Oncology; Massachusetts General Hospital and Harvard Medical School; Boston MA 02114 USA
| | - Brian Wang
- Department of Radiation Oncology; University of Louisville; Louisville KY 40202 USA
| | - Cheng-Shie Wuu
- Department of Radiation Oncology; Columbia University; New York NY 10032 USA
| | - X. George Xu
- Department of Mechanical, Aerospace, and Nuclear Engineering; Rensselaer Polytechnic Institute; Troy NY 12180 USA
| |
Collapse
|
5
|
Borowicz DM, Malicki J, Mytsin G, Shipulin K. Dose distribution at the Bragg peak: Dose measurements using EBT and RTQA gafchromic film set at two positions to the central beam axis. Med Phys 2017; 44:1538-1544. [PMID: 28196271 DOI: 10.1002/mp.12159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Revised: 01/23/2017] [Accepted: 02/05/2017] [Indexed: 11/08/2022] Open
Abstract
AIM To evaluate the impact of radiochromic film positioning relative to the central beam axis (CAX) in proton beam therapy. Secondarily, to compare the dosimetric measurements obtained by RTQA and EBT film and to compare these to the doses calculated by the treatment planning system (TPS). METHODS The EBT and RTQA dosimetric radiochromic films were immersed in a water phantom and irradiated with a proton beam. The films were placed parallel to the CAX and at a 5° angle on the horizontal plane to assess the effect of film inclination on Bragg peak profiles. Calibration was performed by irradiating small pieces of film at doses ranging from 0.0 Gy to 3.5 Gy in increments of 0.5 Gy. The TPS was used to create treatment plans for two different geometrical targets (cylindrical and cuboidal). After irradiation, all film pieces were scanned on a flatbed scanner and red channel data were extracted from the 48-bit RGB images using ImageJ, Photoshop, Origin8, and Excel software. The dose distributions from the irradiated films were compared to the dose obtained from the TPS. Bragg peak profiles were abstracted from the irradiated films and compared. RESULTS The dosimetric measurements obtained by both EBT and RTQA positioned at a 5° to the CAX closely matched the dose calculated by the TPS for the cylindrical target. In contrast, dose distributions measured in the cuboidal targets were less precise. Gamma index (GI) values (3%/3 mm acceptance criteria for isodose >90% of dose) were 99.8% and 93% for EBT film placed at a 5° angle versus 47.1% and 80.8% for EBT film parallel to the beam. The dosimetric measurements in RTQA film positioned parallel to the CAX showed GI values with <27% agreement with the TPS-calculated dose. CONCLUSION Our finding show that RTQA film can be used to accurately measure doses in the proton beam at the region of Bragg peak; however, to obtain the most accurate readings, the film should be positioned at a small angle to the CAX.
Collapse
Affiliation(s)
- Dorota Maria Borowicz
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland.,Laboratory of Nuclear Problems, Joint Institute for Nuclear Research, 141980, Dubna, Moscow region, Russia
| | - Julian Malicki
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland.,Electroradiology Department, University of Medical Sciences, Poznan, Poland
| | - Gennady Mytsin
- Laboratory of Nuclear Problems, Joint Institute for Nuclear Research, 141980, Dubna, Moscow region, Russia
| | - Konstantin Shipulin
- Laboratory of Nuclear Problems, Joint Institute for Nuclear Research, 141980, Dubna, Moscow region, Russia
| |
Collapse
|
6
|
Bourgouin A, Varfalvy N, Archambault L. Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy. J Appl Clin Med Phys 2015; 16:411-422. [PMID: 26699550 PMCID: PMC5691028 DOI: 10.1120/jacmp.v16i6.5317] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 08/31/2015] [Accepted: 08/10/2015] [Indexed: 11/23/2022] Open
Abstract
The objectives of this project are to quantify the dose reduction effect provided by a lead shield for patients with cardiac implantable electronic devices (CIED) during a clinically realistic radiation treatment on phantom and to provide a simple model of dose estimation to predict dose received by CIED in a wide range of situations. The shield used in this project is composed of a lead sheet wrapped in thermoplastic. Dose measurements were made with a plastic scintillation detector (PSD). The phantom was treated with ten different plans. Three of these cases were treated with intensity-modulated radiation therapy (IMRT) and the others received standard 3D conformal radiation therapy (3D CRT). Lateral dose measurement for photon fields was made to establish a dose prediction model. On average, the use of the lead shield reduced the dose to CIEDs by 19% ± 13%. Dose reduction was most important for breast cases, with a mean reduction of 31% ± 15%. In three cases, the total dose reduction was more than 25 cGy over the complete treatment. For the three IMRT cases, the mean dose reduction was 11% ± 9%. On average, the difference between the TPS prediction and the measurement was 71%, while it was only 14% for the dose prediction model. It was demonstrated that a lead shield can be efficiently used for reducing doses to CIED with a wide range of clinical plans. In patients treated with IMRT modality treatment, the shielding should be used only for those with more than two anterior fields over seven fields. In the case of 3D CRT patients, the shielding should be used for those with a dose on the CIED higher than 50 cGy and with a reduction of dose higher than 10 cGy. The dose prediction model developed in this study can be an easy way to have a better estimation of the out-of-field dose than the TPS.
Collapse
|
7
|
Aldosari AH, Petasecca M, Espinoza A, Newall M, Fuduli I, Porumb C, Alshaikh S, Alrowaili ZA, Weaver M, Metcalfe P, Carolan M, Lerch MLF, Perevertaylo V, Rosenfeld AB. A two dimensional silicon detectors array for quality assurance in stereotactic radiotherapy: MagicPlate-512. Med Phys 2014; 41:091707. [DOI: 10.1118/1.4892384] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
8
|
Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters. Med Dosim 2012; 37:334-8. [DOI: 10.1016/j.meddos.2011.11.007] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2011] [Revised: 09/16/2011] [Accepted: 11/08/2011] [Indexed: 11/19/2022]
|