1
|
Wang J, Weller DS, Kramer CM, Salerno M. DEep learning-based rapid Spiral Image REconstruction (DESIRE) for high-resolution spiral first-pass myocardial perfusion imaging. NMR IN BIOMEDICINE 2022; 35:e4661. [PMID: 34939246 DOI: 10.1002/nbm.4661] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 11/01/2021] [Accepted: 11/16/2021] [Indexed: 06/14/2023]
Abstract
The objective of the current study was to develop and evaluate a DEep learning-based rapid Spiral Image REconstruction (DESIRE) technique for high-resolution spiral first-pass myocardial perfusion imaging with whole-heart coverage, to provide fast and accurate image reconstruction for both single-slice (SS) and simultaneous multislice (SMS) acquisitions. Three-dimensional U-Net-based image enhancement architectures were evaluated for high-resolution spiral perfusion imaging at 3 T. The SS and SMS MB = 2 networks were trained on SS perfusion images from 156 slices from 20 subjects. Structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and normalized root mean square error (NRMSE) were assessed, and prospective images were blindly graded by two experienced cardiologists (5: excellent; 1: poor). Excellent performance was demonstrated for the proposed technique. For SS, SSIM, PSNR, and NRMSE were 0.977 [0.972, 0.982], 42.113 [40.174, 43.493] dB, and 0.102 [0.080, 0.125], respectively, for the best network. For SMS MB = 2 retrospective data, SSIM, PSNR, and NRMSE were 0.961 [0.950, 0.969], 40.834 [39.619, 42.004] dB, and 0.107 [0.086, 0.133], respectively, for the best network. The image quality scores were 4.5 [4.1, 4.8], 4.5 [4.3, 4.6], 3.5 [3.3, 4], and 3.5 [3.3, 3.8] for SS DESIRE, SS L1-SPIRiT, MB = 2 DESIRE, and MB = 2 SMS-slice-L1-SPIRiT, respectively, showing no statistically significant difference (p = 1 and p = 1 for SS and SMS, respectively) between L1-SPIRiT and the proposed DESIRE technique. The network inference time was ~100 ms per dynamic perfusion series with DESIRE, while the reconstruction time of L1-SPIRiT with GPU acceleration was ~ 30 min. It was concluded that DESIRE enabled fast and high-quality image reconstruction for both SS and SMS MB = 2 whole-heart high-resolution spiral perfusion imaging.
Collapse
Affiliation(s)
- Junyu Wang
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Daniel S Weller
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia, USA
| | - Christopher M Kramer
- Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA
- Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia, USA
| | - Michael Salerno
- Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
- Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA
- Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia, USA
- Departments of Medicine and Radiology, Stanford University Medical Center, Stanford, California, USA
| |
Collapse
|
2
|
Demirel OB, Weingärtner S, Moeller S, Akçakaya M. Improved simultaneous multislice cardiac MRI using readout concatenated k-space SPIRiT (ROCK-SPIRiT). Magn Reson Med 2021; 85:3036-3048. [PMID: 33566378 DOI: 10.1002/mrm.28680] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 12/21/2020] [Accepted: 12/22/2020] [Indexed: 01/31/2023]
Abstract
PURPOSE To develop and evaluate a simultaneous multislice (SMS) reconstruction technique that provides noise reduction and leakage blocking for highly accelerated cardiac MRI. METHODS ReadOut Concatenated k-space SPIRiT (ROCK-SPIRiT) uses the concept of readout concatenation in image domain to represent SMS encoding, and performs coil self-consistency as in SPIRiT-type reconstruction in an extended k-space, while allowing regularization for further denoising. The proposed method is implemented with and without regularization, and validated on retrospectively SMS-accelerated cine imaging with three-fold SMS and two-fold in-plane acceleration. ROCK-SPIRiT is compared with two leakage-blocking SMS reconstruction methods: readout-SENSE-GRAPPA and split slice-GRAPPA. Further evaluation and comparisons are performed using prospectively SMS-accelerated cine imaging. RESULTS Results on retrospectively three-fold SMS and two-fold in-plane accelerated cine imaging show that ROCK-SPIRiT without regularization significantly improves on existing methods in terms of PSNR (readout-SENSE-GRAPPA: 33.5 ± 3.2, split slice-GRAPPA: 34.1 ± 3.8, ROCK-SPIRiT: 35.0 ± 3.3) and SSIM (readout-SENSE-GRAPPA: 84.4 ± 8.9, split slice-GRAPPA: 85.0 ± 8.9, ROCK-SPIRiT: 88.2 ± 6.6 [in percentage]). Regularized ROCK-SPIRiT significantly outperforms all methods, as characterized by these quantitative metrics (PSNR: 37.6 ± 3.8, SSIM: 94.2 ± 4.1 [in percentage]). The prospectively five-fold SMS and two-fold in-plane accelerated data show that ROCK-SPIRiT and regularized ROCK-SPIRiT have visually improved image quality compared with existing methods. CONCLUSION The proposed ROCK-SPIRiT technique reduces noise and interslice leakage in accelerated SMS cardiac cine MRI, improving on existing methods both quantitatively and qualitatively.
Collapse
Affiliation(s)
- Omer Burak Demirel
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA.,Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Sebastian Weingärtner
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA.,Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.,Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Steen Moeller
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Mehmet Akçakaya
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA.,Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
3
|
Hermann I, Martínez-Heras E, Rieger B, Schmidt R, Golla AK, Hong JS, Lee WK, Yu-Te W, Nagtegaal M, Solana E, Llufriu S, Gass A, Schad LR, Weingärtner S, Zöllner FG. Accelerated white matter lesion analysis based on simultaneous T 1 and T 2 ∗ quantification using magnetic resonance fingerprinting and deep learning. Magn Reson Med 2021; 86:471-486. [PMID: 33547656 DOI: 10.1002/mrm.28688] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/27/2020] [Accepted: 12/28/2020] [Indexed: 02/06/2023]
Abstract
PURPOSE To develop an accelerated postprocessing pipeline for reproducible and efficient assessment of white matter lesions using quantitative magnetic resonance fingerprinting (MRF) and deep learning. METHODS MRF using echo-planar imaging (EPI) scans with varying repetition and echo times were acquired for whole brain quantification of T 1 and T 2 ∗ in 50 subjects with multiple sclerosis (MS) and 10 healthy volunteers along 2 centers. MRF T 1 and T 2 ∗ parametric maps were distortion corrected and denoised. A CNN was trained to reconstruct the T 1 and T 2 ∗ parametric maps, and the WM and GM probability maps. RESULTS Deep learning-based postprocessing reduced reconstruction and image processing times from hours to a few seconds while maintaining high accuracy, reliability, and precision. Mean absolute error performed the best for T 1 (deviations 5.6%) and the logarithmic hyperbolic cosinus loss the best for T 2 ∗ (deviations 6.0%). CONCLUSIONS MRF is a fast and robust tool for quantitative T 1 and T 2 ∗ mapping. Its long reconstruction and several postprocessing steps can be facilitated and accelerated using deep learning.
Collapse
Affiliation(s)
- Ingo Hermann
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.,Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Eloy Martínez-Heras
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomédiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Benedikt Rieger
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Ralf Schmidt
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Alena-Kathrin Golla
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.,Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Jia-Sheng Hong
- Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan
| | - Wei-Kai Lee
- Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan
| | - Wu Yu-Te
- Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan.,Institute of Biophotonics and Brain Research Center, National Yang-Ming University, Taipei, Taiwan
| | - Martijn Nagtegaal
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Elisabeth Solana
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomédiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Sara Llufriu
- Center of Neuroimmunology, Laboratory of Advanced Imaging in Neuroimmunological Diseases, Hospital Clinic Barcelona, Institut d'Investigacions Biomédiques August Pi i Sunyer (IDIBAPS) and Universitat de Barcelona, Barcelona, Spain
| | - Achim Gass
- Department of Neurology, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Lothar R Schad
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
| | - Frank G Zöllner
- Computer Assisted Clinical Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.,Mannheim Institute for Intelligent Systems in Medicine, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| |
Collapse
|