1
|
Javaid A, Jalalah M, Safdar R, Khaliq Z, Qadir MB, Zulfiqar S, Ahmad A, Satti AN, Ali A, Faisal M, Alsareii SA, Harraz FA. Ginger Loaded Polyethylene Oxide Electrospun Nanomembrane: Rheological and Antimicrobial Attributes. MEMBRANES 2022; 12:membranes12111148. [PMID: 36422140 PMCID: PMC9696929 DOI: 10.3390/membranes12111148] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 11/01/2022] [Accepted: 11/08/2022] [Indexed: 05/29/2023]
Abstract
Synthetic antibiotics have captured the market in recent years, but the side effects of these products are life-threatening. In recent times, researchers have focused their research on natural-based products such as natural herbal oils, which are eco-friendly, biocompatible, biodegradable, and antibacterial. In this study, polyethylene oxide (PEO) and aqueous ginger extract (GE) were electrospun to produce novel antibacterial nanomembrane sheets as a function of PEO and GE concentrations. A GE average particle size of 91.16 nm was achieved with an extensive filtration process, inferring their incorporation in the PEO nanofibres. The presence of the GE was confirmed by Fourier transform infrared spectroscopy (FTIR) through peaks of phenol and aromatic groups. The viscoelastic properties of PEO/GE solutions were analysed in terms of PEO and GE concentrations. Increasing PEO and GE concentrations increased the solution's viscosity. The dynamic viscosity of 3% was not changed with increasing shear rate, indicating Newtonian fluid behaviour. The dynamic viscosity of 4 and 5 wt% PEO/GE solutions containing 10% GE increased exponentially compared to 3 wt%. In addition, the shear thinning behaviour was observed over a frequency range of 0.05 to 100 rad/s. Scanning Electron Microscopy (SEM) analysis also specified an increase in the nanofibre's diameter with increasing PEO concentration, while SEM images displayed smooth morphology with beadless nanofibres at different PEO/GE concentrations. In addition, PEO/GE nanomembranes inhibited the growth of Staphylococcus aureus, as presented by qualitative antibacterial results. The extent of PEO/GE nanomembrane's antibacterial activity was further investigated by the agar dilution method, which inhibited the 98.79% Staphylococcus aureus population at 30% GE concentration.
Collapse
Affiliation(s)
- Anum Javaid
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - Mohammed Jalalah
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
- Department of Electrical Engineering, College of Engineering, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
| | - Rimsha Safdar
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - Zubair Khaliq
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - Muhammad Bilal Qadir
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - Sumra Zulfiqar
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - Adnan Ahmad
- Department of Textile Engineering, National Textile University, Faisalabad 37610, Pakistan
| | - Aamir Naseem Satti
- U.S.-PAKISTAN Center for Advanced Studies in Energy (USPCASE), National University of Science and Technology, Islamabad 44000, Pakistan
| | - Aiman Ali
- Department of Materials, National Textile University, Faisalabad 37610, Pakistan
| | - M. Faisal
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
- Department of Chemistry, Faculty of Science and Arts, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
| | - S. A. Alsareii
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
- Department of Surgery, College of Medicine, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
| | - Farid A. Harraz
- Promising Centre for Sensors and Electronic Devices (PCSED), Advanced Materials and Nano-Research Centre, Najran University, P.O. Box 1988, Najran 11001, Saudi Arabia
- Department of Chemistry, Faculty of Science and Arts, Sharurah, Najran University, Sharurah 68342, Saudi Arabia
| |
Collapse
|
2
|
Lefeuvre C, Lefort C, Boyer F, Le Cam S, Mouna L, Roque-Afonso AM, Le Guillou-Guillemette H, Mahieu R. Transfusion-Transmitted Hepatitis A Virus, France, 2018. Emerg Infect Dis 2022; 28:219-223. [PMID: 34932935 PMCID: PMC8714218 DOI: 10.3201/eid2801.210403] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
We report a transfusion-transmitted hepatitis A virus infection in an immunocompromised patient in France, detected shortly after a transfusion of pathogen-reduced pooled platelets. This case raises questions about the efficacy of donor screening methods. Additional safety measures, such as routine donation screening, should be considered.
Collapse
|
3
|
Pérez Aliaga AI, Labata G, Aranda A, Cardoso M, Puente F, Domingo JM, Garcés C. Improvement of Blood Processing and Safety by Automation and Pathogen Reduction Technology. Transfus Med Hemother 2021; 48:290-297. [PMID: 34803572 DOI: 10.1159/000516696] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 04/02/2021] [Indexed: 01/18/2023] Open
Abstract
Introduction The objective of the present study was to describe the experience of the Blood and Tissues Bank of Aragon with the Reveos® Automated Blood Processing System and Mirasol® Pathogen Reduction Technology (PRT) System, comparing retrospectively routine quality data obtained in two different observation periods. Methods Comparing quality data encompassing 6,525 blood components from the period 2007-2012, when the semi-automated buffy coat method was used in routine, with 6,553 quality data from the period 2014-2019, when the Reveos system and subsequently the Mirasol system were implemented in routine. Results Moving from buffy coat to Reveos led to decreased discard rates of whole blood units (1.2 to 0.1%), increased hemoglobin content (48.1 ± 7.6 to 55.4 ± 6.6 g/unit), and hematocrit (58.9 ± 6.5% to 60.0 ± 4.9%) in red blood cell concentrates. Platelet concentrates (PCs) in both periods had similar yields (3.5 ×1011). Whereas in the earlier period, PCs resulted from pooling 5 buffy coats, in the second period 25% of PCs were prepared from 4 interim platelet units. The mean level of factor VIII in plasma was significantly higher with Reveos (92.8 vs. 97.3 IU). Mirasol PRT treatment of PCs reduced expiry rates to 1.2% in 2019. One septic transmission was reported with a non-PRT treated PCs, but none with PRT-treated PCs. Conclusion Automation contributed to standardization, efficiency, and improvement of blood processing. Released resources enabled the effortless implementation of PRT. The combination of both technologies guaranteed the self-sufficiency and improvement of blood safety.
Collapse
Affiliation(s)
| | - Gorka Labata
- Technological Institute of Aragón, Zaragoza, Spain
| | | | | | | | | | | |
Collapse
|
4
|
Fachini RM, Fontão-Wendel R, Achkar R, Scuracchio P, Brito M, Amaral M, Wendel S. The 4-Year Experience with Implementation and Routine Use of Pathogen Reduction in a Brazilian Hospital. Pathogens 2021; 10:pathogens10111499. [PMID: 34832654 PMCID: PMC8621808 DOI: 10.3390/pathogens10111499] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 11/09/2021] [Accepted: 11/11/2021] [Indexed: 11/16/2022] Open
Abstract
(1) Background: We reviewed the logistics of the implementation of pathogen reduction (PR) using the INTERCEPT Blood System™ for platelets and the experience with routine use and clinical outcomes in the patient population at the Sírio-Libanês Hospital of São Paulo, Brazil. (2) Methods: Platelet concentrate (PC), including pathogen reduced (PR-PC) production, inventory management, discard rates, blood utilization, and clinical outcomes were analyzed over the 40 months before and after PR implementation. Age distribution and wastage rates were compared over the 10 months before and after approval for PR-PC to be stored for up to seven days. (3) Results: A 100% PR-PC inventory was achieved by increasing double apheresis collections and production of double doses using pools of two single apheresis units. Discard rates decreased from 6% to 3% after PR implementation and further decreased to 1.2% after seven-day storage extension for PR-PCs. The blood utilization remained stable, with no increase in component utilization. A significant decrease in adverse transfusion events was observed after the PR implementation. (4) Conclusion: Our experience demonstrates the feasibility for Brazilian blood centers to achieve a 100% PR-PC inventory. All patients at our hospital received PR-PC and showed no increase in blood component utilization and decreased rates of adverse transfusion reactions.
Collapse
|
5
|
Hayashi T, Oguma K, Fujimura Y, Furuta RA, Tanaka M, Masaki M, Shinbata Y, Kimura T, Tani Y, Hirayama F, Takihara Y, Takahashi K. UV light-emitting diode (UV-LED) at 265 nm as a potential light source for disinfecting human platelet concentrates. PLoS One 2021; 16:e0251650. [PMID: 34014978 PMCID: PMC8136854 DOI: 10.1371/journal.pone.0251650] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 04/30/2021] [Indexed: 12/20/2022] Open
Abstract
The risk of sepsis through bacterial transmission is one of the most serious problems in platelet transfusion. In processing platelet concentrates (PCs), several methods have been put into practice to minimize the risk of bacterial transmission, such as stringent monitoring by cultivation assays and inactivation treatment by photoirradiation with or without chemical agents. As another potential option, we applied a light-emitting diode (LED) with a peak emission wavelength of 265 nm, which has been shown to be effective for water, to disinfect PCs. In a bench-scale UV-LED exposure setup, a 10-min irradiation, corresponding to an average fluence of 9.2 mJ/cm2, resulted in >2.0 log, 1.0 log, and 0.6 log inactivation (mean, n = 6) of Escherichia coli, Staphylococcus aureus, and Bacillus cereus, respectively, in non-diluted plasma PCs. After a 30-min exposure, platelet counts decreased slightly (18 ± 7%: mean ± SD, n = 7); however, platelet surface expressions of CD42b, CD61, CD62P, and PAC-1 binding did not change significantly (P>0.005), and agonist-induced aggregation and adhesion/aggregation under flow conditions were well maintained. Our findings indicated that the 265 nm UV-LED has high potential as a novel disinfection method to ensure the microbial safety of platelet transfusion.
Collapse
Affiliation(s)
- Tomoya Hayashi
- Japanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan
- * E-mail:
| | | | | | - Rika A. Furuta
- Central Blood Institute, Japanese Red Cross, Tokyo, Japan
| | - Mitsunobu Tanaka
- Japanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan
| | - Mikako Masaki
- Japanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan
| | | | - Takafumi Kimura
- Japanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan
| | - Yoshihiko Tani
- Central Blood Institute, Japanese Red Cross, Tokyo, Japan
| | - Fumiya Hirayama
- Japanese Red Cross Kinki Block Blood Centre, Ibaraki, Osaka, Japan
| | | | - Koki Takahashi
- Blood Service Headquarters, Japanese Red Cross, Tokyo, Japan
| |
Collapse
|
6
|
Azhar EI, Hindawi SI, El-Kafrawy SA, Hassan AM, Tolah AM, Alandijany TA, Bajrai LH, Damanhouri GA. Amotosalen and ultraviolet A light treatment efficiently inactivates severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in human plasma. Vox Sang 2020; 116:673-681. [PMID: 33277935 PMCID: PMC8359189 DOI: 10.1111/vox.13043] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2020] [Revised: 11/13/2020] [Accepted: 11/15/2020] [Indexed: 12/11/2022]
Abstract
Background and objectives During the ongoing pandemic of COVID‐19, SARS‐CoV‐2 RNA was detected in plasma and platelet products from asymptomatic blood donors, raising concerns about potential risk of transfusion transmission, also in the context of the current therapeutic approach utilizing plasma from convalescent donors. The objective of this study was to assess the efficacy of amotosalen/UVA light treatment to inactivate SARS‐CoV‐2 in human plasma to reduce the risk of potential transmission through blood transfusion. Methods Pools of three whole‐blood‐derived human plasma units (630–650 ml) were inoculated with a clinical SARS‐CoV‐2 isolate. Spiked units were treated with amotosalen/UVA light (INTERCEPT Blood System™) to inactivate SARS‐CoV‐2. Infectious titres and genomic viral load were assessed by plaque assay and real‐time quantitative PCR. Inactivated samples were subject to three successive passages on permissive tissue culture to exclude the presence of replication‐competent viral particles. Results Inactivation of infectious viral particles in spiked plasma units below the limit of detection was achieved by amotosalen/UVA light treatment with a mean log reduction of >3·32 ± 0·2. Passaging of inactivated samples on permissive tissue showed no viral replication even after 9 days of incubation and three passages, confirming complete inactivation. The treatment also inhibited NAT detection by nucleic acid modification with a mean log reduction of 2·92 ± 0·87 PFU genomic equivalents. Conclusion Amotosalen/UVA light treatment of SARS‐CoV‐2 spiked human plasma units efficiently and completely inactivated >3·32 ± 0·2 log of SARS‐CoV‐2 infectivity, showing that such treatment could minimize the risk of transfusion‐related SARS‐CoV‐2 transmission.
Collapse
Affiliation(s)
- Esam I Azhar
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Salwa I Hindawi
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Hematology, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Sherif A El-Kafrawy
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Ahmed M Hassan
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Ahmed M Tolah
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Thamir A Alandijany
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Medical Laboratory Technology, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Leena H Bajrai
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Biochemistry Department, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Ghazi A Damanhouri
- Special Infectious Agents Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah, Saudi Arabia.,Department of Hematology, Faculty of Medicine, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
7
|
Lanteri MC, Santa-Maria F, Laughhunn A, Girard YA, Picard-Maureau M, Payrat JM, Irsch J, Stassinopoulos A, Bringmann P. Inactivation of a broad spectrum of viruses and parasites by photochemical treatment of plasma and platelets using amotosalen and ultraviolet A light. Transfusion 2020; 60:1319-1331. [PMID: 32333396 PMCID: PMC7317863 DOI: 10.1111/trf.15807] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2020] [Revised: 03/12/2020] [Accepted: 03/13/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND The INTERCEPT Blood System pathogen reduction technology (PRT), which uses amotosalen and ultraviolet A light treatment (amotosalen/UV-PRT), inactivates pathogens in plasma and platelet components (PCs). This review summarizes data describing the inactivation efficacy of amotosalen/UVA-PRT for a broad spectrum of viruses and parasites. METHODS Twenty-five enveloped viruses, six nonenveloped viruses (NEVs), and four parasites species were evaluated for sensitivity to amotosalen/UVA-PRT. Pathogens were spiked into plasma and PC at high titers. Samples were collected before and after PRT and assessed for infectivity with cell cultures or animal models. Log reduction factors (LRFs) were defined as the difference in infectious titers before and after amotosalen/UV-PRT. RESULTS LRFs of ≥4.0 log were reported for 19 pathogens in plasma (range, ≥4.0 to ≥7.6), 28 pathogens in PC in platelet additive solution (PC-PAS; ≥4.1-≥7.8), and 14 pathogens in PC in 100% plasma (PC-100%; (≥4.3->8.4). Twenty-five enveloped viruses and two NEVs were sensitive to amotosalen/UV-PRT; LRF ranged from >2.9 to ≥7.6 in plasma, 2.4 or greater to greater than 6.9 in PC-PAS and >3.5 to >6.5 in PC-100%. Infectious titers for four parasites were reduced by >4.0 log in all PC and plasma (≥4.9 to >8.4). CONCLUSION Amotosalen/UVA-PRT demonstrated effective infectious titer reduction for a broad spectrum of viruses and parasites. This confirms the capacity of this system to reduce the risk of viral and parasitic transfusion-transmitted infections by plasma and PCs in various geographies.
Collapse
Affiliation(s)
- Marion C Lanteri
- Department of Scientific Affairs, Cerus Corporation, Concord, California, USA
| | | | - Andrew Laughhunn
- Department of Microbiology, Cerus Corporation, Concord, California, USA
| | - Yvette A Girard
- Department of Microbiology, Cerus Corporation, Concord, California, USA
| | | | - Jean-Marc Payrat
- Department of Scientific Affairs, Cerus Europe BV, Amersfoort, The Netherlands
| | - Johannes Irsch
- Department of Scientific Affairs, Cerus Europe BV, Amersfoort, The Netherlands
| | | | - Peter Bringmann
- Department of Microbiology, Cerus Corporation, Concord, California, USA
| |
Collapse
|