Palmisano P, Parlavecchio A, Guido A, Accogli M, Coluccia G. Upgrade from leadless to transvenous pacemaker with left bundle branch area pacing: A case report. Pacing Clin Electrophysiol 2024; 47:1057-1060. [PMID: 38264957 DOI: 10.1111/pace.14925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/12/2023] [Accepted: 01/02/2024] [Indexed: 01/25/2024]
Abstract
An 80-years-old patient with permanent atrial fibrillation and symptomatic, paroxysmal atrioventricular blocks (AVBs) underwent leadless pacemaker (L-PM) implantation. Seven years after implantation, as a consequence of a progression of the AVB towards a persistent form, resulting in an increased need for pacing, he developed a pacing-induced cardiomyopathy. He then underwent a successful upgrade from L-PM to a transvenous pacemaker (T-PM) with left bundle branch area pacing (LBBAP). The L-PM did not interfere with the T-PM and was turned off and abandoned. One month after the upgrading the patient showed a significant improvement in cardiac function and functional capacity.
Collapse
Affiliation(s)
| | - Antonio Parlavecchio
- Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy
- Cardiology Unit, Department of Clinical and Experimental Medicine, University of Messina, Messina, Italy
| | | | | | | |
Collapse
|
2
|
Palmisano P, Guerra F, Aspromonte V, Dell’Era G, Pellegrino PL, Laffi M, Uran C, De Bonis S, Accogli M, Russo AD, Patti G, Santoro F, Torriglia A, Nigro G, Bisignani A, Coluccia G, Stronati G, Russo V, Ammendola E. Management of older patients with unexplained, recurrent, traumatic syncope and bifascicular block: implantable loop recorder versus empiric pacemaker implantation. Results of a propensity matched analysis. Heart Rhythm 2022; 19:1696-1703. [PMID: 35643299 DOI: 10.1016/j.hrthm.2022.05.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Revised: 05/09/2022] [Accepted: 05/17/2022] [Indexed: 11/25/2022]
|
3
|
Akhtar Z, Leung LW, Kontogiannis C, Zuberi Z, Bajpai A, Sharma S, Chen Z, Beeton I, Sohal M, Gallagher MM. Prevalence of bradyarrhythmias needing pacing in COVID-19. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021; 44:1340-1346. [PMID: 34240439 PMCID: PMC8447422 DOI: 10.1111/pace.14313] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 06/19/2021] [Accepted: 07/04/2021] [Indexed: 12/15/2022]
Abstract
Background The Sars‐Cov‐2 infection is a multisystem illness that can affect the cardiovascular system. Tachyarrhythmias have been reported but the prevalence of bradyarrhythmia is unclear. Cases have been described of transient high‐degree atrioventricular (AV) block in COVID‐19 that were managed conservatively. Method A database of all patients requiring temporary or permanent pacing in two linked cardiac centers was used to compare the number of procedures required during the first year of the pandemic compared to the corresponding period a year earlier. The database was cross‐referenced with a database of all patients testing positive for Sars‐Cov‐2 infection in both institutions to identify patients who required temporary or permanent pacing during COVID‐19. Results The number of novel pacemaker implants was lower during the COVID‐19 pandemic than the same period the previous year (540 vs. 629, respectively), with a similar proportion of high‐degree AV block (38.3% vs. 33.2%, respectively, p = .069). Four patients with the Sars‐Cov‐2 infection had a pacemaker implanted for high‐degree AV block, two for sinus node dysfunction. Of this cohort of six patients, two succumbed to the COVID‐19 illness and one from non‐COVID sepsis. Device interrogation demonstrated a sustained pacing requirement in all cases. Conclusion High‐degree AV block remained unaltered in prevalence during the COVID‐19 pandemic. There was no evidence of transient high‐degree AV block in patients with the Sars‐Cov‐2 infection. Our experience suggests that all clinically significant bradyarrhythmia should be treated by pacing according to usual protocols regardless of the COVID status.
Collapse
Affiliation(s)
- Zaki Akhtar
- Cardiology, St George's University Hospital NHS trust, London, UK.,Cardiology, Ashford and St Peter's Hospitals NHS trust, Surrey, UK
| | - Lisa Wm Leung
- Cardiology, St George's University Hospital NHS trust, London, UK
| | | | - Zia Zuberi
- Cardiology, St George's University Hospital NHS trust, London, UK.,Cardiology, Royal Surrey County Hospital, Surrey, UK
| | - Abhay Bajpai
- Cardiology, St George's University Hospital NHS trust, London, UK.,Cardiology, Epsom and St Heliers University Hospitals, London, UK
| | - Sumeet Sharma
- Cardiology, St George's University Hospital NHS trust, London, UK
| | - Zhong Chen
- Cardiology, Ashford and St Peter's Hospitals NHS trust, Surrey, UK
| | - Ian Beeton
- Cardiology, Ashford and St Peter's Hospitals NHS trust, Surrey, UK
| | - Manav Sohal
- Cardiology, St George's University Hospital NHS trust, London, UK
| | - Mark M Gallagher
- Cardiology, St George's University Hospital NHS trust, London, UK.,Cardiology, Ashford and St Peter's Hospitals NHS trust, Surrey, UK.,Cardiology, Epsom and St Heliers University Hospitals, London, UK
| |
Collapse
|
4
|
Boriani G, Sakamoto Y, Botto G, Komura S, Pieragnoli P, Minamiguchi H, Iacopino S, Noma T, Infusino T, Takahashi Y, Facchin D, De Rosa F, Pisanò E, Meloni S, Biffi M. Prevention of long-lasting atrial fibrillation through antitachycardia pacing in DDDR pacemakers. Int J Clin Pract 2021; 75:e13820. [PMID: 33164319 DOI: 10.1111/ijcp.13820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 10/10/2020] [Accepted: 11/02/2020] [Indexed: 12/01/2022] Open
Abstract
OBJECTIVE The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. METHODS Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. RESULTS A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). CONCLUSIONS In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing.
Collapse
Affiliation(s)
- Giuseppe Boriani
- Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena University Hospital, Modena, Italy
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Mauro Biffi
- Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, S. Orsola University Hospital, Bologna, Italy
| |
Collapse
|
5
|
Palmisano P, Dell'Era G, Pellegrino PL, Ammendola E, Ziacchi M, Guerra F, Aspromonte V, Laffi M, Pimpini L, Santoro F, Boggio E, Guido A, Patti G, Brunetti ND, Nigro G, Biffi M, Russo AD, Gaggioli G, Accogli M. Causes of syncopal recurrences in patients treated with permanent pacing for bradyarrhythmic syncope: Findings from the SYNCOPACED registry. Heart Rhythm 2021; 18:770-777. [PMID: 33465512 DOI: 10.1016/j.hrthm.2021.01.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 01/06/2021] [Accepted: 01/07/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND Few studies have examined the causes of syncope/collapse recurrences in patients with a previously implanted pacemaker for bradyarrhythmic syncope. OBJECTIVE The purpose of this study was to assess the causes of syncope/collapse recurrences after pacemaker implantation for bradyarrhythmic syncope in a large patient population. METHODS The SYNCOpal recurrences in patients treated with permanent PACing for bradyarrhythmic syncope (SYNCOPACED) registry was a prospective multicenter observational registry enrolling 1364 consecutive patients undergoing pacemaker implantation for bradyarrhythmic syncope. During follow-up, the time to the first syncope/collapse recurrence was recorded. Patients with syncope/collapse recurrences underwent a predefined diagnostic workup aimed at establishing the mechanism of syncope/collapse. RESULTS During a median follow-up of 50 months, 213 patients (15.6%) reported at least 1 syncope/collapse recurrence. The risk of syncope/collapse recurrence was highest in patients who underwent implantation for cardioinhibitory vasovagal syncope (26.4%), followed by unexplained syncope and chronic bifascicular block (21.5%), cardioinhibitory carotid sinus syndrome (17.2%), atrial fibrillation needing pacing (15.5%), atrioventricular block (13.6%), and sinus node disease (12.5%) (P = .017). The most frequent cause of syncope/collapse recurrence was reflex syncope (27.7%), followed by orthostatic hypotension (26.3%), pacemaker or lead malfunction (5.6%), structural cardiac disease (5.2%), and atrial and ventricular tachyarrhythmias (4.7% and 3.8%, respectively). In 26.8% of cases, the mechanism of syncope/collapse remained unexplained. CONCLUSION In patients receiving a pacemaker for bradyarrhythmic syncope, reflex syncope and orthostatic hypotension are the most frequent mechanisms of syncope/collapse recurrence after implantation. Pacing system malfunction, structural cardiac diseases, and tachyarrhythmias are rare mechanisms. The mechanism remains unexplained in >25% of patients.
Collapse
Affiliation(s)
| | - Gabriele Dell'Era
- Azienda Ospedaliera Universitaria "Maggiore della Carità," Novara, Italy
| | | | - Ernesto Ammendola
- Dipartimento di Cardiologia, Università della Campania - L.Vanvitelli, Ospedale Monaldi, Napoli, Italy
| | - Matteo Ziacchi
- Institute of Cardiology, University of Bologna, S.Orsola-Malpighi University Hospital, Bologna, Italy
| | - Federico Guerra
- Cardiology and Arrhythmology Clinic, Marche Polytechnic University, University Hospital "Umberto I - Lancisi - Salesi," Ancona, Italy
| | - Vittorio Aspromonte
- Cardiology - Coronary Care Unit, Pugliese-Ciaccio Hospital, Catanzaro, Italy
| | - Mattia Laffi
- Cardiology Division, Villa Scassi Hospital, Genova ASL 3, Genova, Italy
| | - Lorenzo Pimpini
- Unit of Cardiology-CCU, Italian National Research Centre on Aging, Ancona, Italy
| | - Francesco Santoro
- Department of Cardiology, Bonomo Hospital, Andria, Italy; Department of Medical and Surgery Sciences, University of Foggia, Foggia, Italy
| | - Enrico Boggio
- Azienda Ospedaliera Universitaria "Maggiore della Carità," Novara, Italy
| | | | - Giuseppe Patti
- Azienda Ospedaliera Universitaria "Maggiore della Carità," Novara, Italy
| | | | - Gerardo Nigro
- Dipartimento di Cardiologia, Università della Campania - L.Vanvitelli, Ospedale Monaldi, Napoli, Italy
| | - Mauro Biffi
- Institute of Cardiology, University of Bologna, S.Orsola-Malpighi University Hospital, Bologna, Italy
| | - Antonio Dello Russo
- Cardiology and Arrhythmology Clinic, Marche Polytechnic University, University Hospital "Umberto I - Lancisi - Salesi," Ancona, Italy
| | - Germano Gaggioli
- Cardiology Division, Villa Scassi Hospital, Genova ASL 3, Genova, Italy
| | | | | |
Collapse
|
6
|
Palmisano P, Melissano D, Zanotto G, Perego GB, Toselli T, Landolina M, Ricci RP. Change in the use of remote monitoring of cardiac implantable electronic devices in Italian clinical practice over a 5-year period: results of two surveys promoted by the AIAC (Italian Association of Arrhythmology and Cardiac Pacing). J Cardiovasc Med (Hagerstown) 2020; 21:305-314. [PMID: 32073430 DOI: 10.2459/jcm.0000000000000950] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS The aim of this study was to evaluate the use of remote monitoring in Italian clinical practice and its trend over the last 5 years. METHODS In 2012 and 2017, two surveys were conducted. Both were open to all Italian implanting centres and consisted of 25 questions on the characteristics of the centre, their actual use of remote monitoring, applied organizational models and administrative and legal aspects. RESULTS The questionnaires were completed by 132 and 108 centres in 2012 and 2017, respectively (30.6 and 24.7% of all Italian implanting centres). In 2017, significantly fewer centres followed up fewer than 200 patients by remote monitoring than in 2012, while more followed up more than 500 patients (all P < 0.005). In most of the centres (77.6%) that responded to both surveys, the number of patients remotely monitored significantly increased from 2012 to 2017.In both surveys, remote monitoring was usually managed by physicians and nurses. Over the period, primary review of transmissions by physicians declined, while it was increasingly performed by nurses; the involvement of technicians rose, while that of manufacturers' technical personnel decreased. The percentage of centres in which transmissions were submitted to the physician only in critical cases rose (from 28.3 to 64.3%; P < 0.001). In 86.7% of centres, the lack of a reimbursement system was deemed the main barrier to implementing remote monitoring. CONCLUSION In the last 5 years, the number of patients followed up by remote monitoring has increased markedly. In most Italian centres, remote monitoring has increasingly been managed through a primary nursing model. The lack of a specific reimbursement system is perceived as the main barrier to implementing remote monitoring .
Collapse
Affiliation(s)
| | | | | | - Giovanni Battista Perego
- Istituto Auxologico Italiano, IRCCS, Dipartimento di Scienze Cardiovascolari, Neurologiche, Metaboliche, Ospedale S. Luca, Milan
| | | | | | | | | |
Collapse
|
7
|
Boriani G, Vitolo M. The 12-lead ECG: a continuous reference for the cardiologist. J Cardiovasc Med (Hagerstown) 2019; 20:459-463. [PMID: 31045692 DOI: 10.2459/jcm.0000000000000803] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Giuseppe Boriani
- Cardiology Division, Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| | | |
Collapse
|
8
|
Palmisano P, Ziacchi M, Belotti G, Rapacciuolo A, Santini L, Stabile G, Zoni Berisso M, De Ponti R, Landolina M, Ricci RP, Boriani G. Clinical and organizational management of cardiac implantable electronic device replacements. J Cardiovasc Med (Hagerstown) 2019; 20:531-541. [DOI: 10.2459/jcm.0000000000000817] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
9
|
Tischer T, Bebersdorf A, Albrecht C, Manhart J, Caglayan E, Öner A, Ince H, Ortak J, Büttner A, Safak E. Individual programming of current multiprogrammable pacemakers : Still unsatisfactory? Herz 2018; 45:572-579. [PMID: 30255303 DOI: 10.1007/s00059-018-4753-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2018] [Revised: 08/22/2018] [Accepted: 08/24/2018] [Indexed: 11/25/2022]
Abstract
BACKGROUND Pacemaker (PM) technology has developed tremendously in recent decades. We evaluated the extent of individual programming in current PMs. METHODS Over a 7-month period in 2016, all deceased persons taken to the Rostock crematorium were prospectively screened for cardiac implantable electronic devices (CIEDs) and these were interrogated in situ. Programming of patient data, leads, and study parameters including mode, lower rate, upper tracking or sensor rate (UTSR), ventricular refractory time, sleeping function, hysteresis, and PM-mediated tachycardia intervention were analyzed and compared with delivery settings. Alterations in atrial/ventricular capture management and atrial/ventricular sensing assurance as well as changes in sensitivity and lead output were evaluated. RESULTS We examined 2297 subjects, of whom 154 (6.7%) had CIEDs, with 125 (81.2%) being PMs. Finally, 72 (57.6%) PMs were eligible for analysis with an operation time of 31.0 ± 27.0 months. We excluded 28 (18.2%) implantable cardioverter defibrillators (ICDs), 51 (41%) PMs presenting elective replacement indicator (ERI), two (1.6%) PMs with programming to insufficient function prior to death, and the left ventricle parameter of one (1.4%) cardiac resynchronization therapy pacemaker (CRT-P); further one CIED (0.6%) was not contactable. PMs offered in mean 75.2% of study parameters thereof 88.0% were to adjust manually, whereof 49.3% stayed unchanged to delivery mode. Lead output, UTSR, lower rate, and mode were the most frequently changed parameters (>85.7%, 65.3%, 54.2%, and 52.8%, respectively) compared with unmodified ventricular refractory time and hysteresis (91.7% and. 85.4%, respectively); 2.8% of PMs had out-of-the-box settings. The most frequent personalized data were last (88.9%) and first name (73.6%), while atrial and ventricular serial lead numbers were rarely entered (18.2% and 23.4%, respectively). CONCLUSION The programming possibilities of PMs have advanced greatly. Nonetheless, improvements in individual PM programming are still needed as demonstrated by the findings in this study, e.g., PMs with manufacturer settings and lack of individual data.
Collapse
Affiliation(s)
- T Tischer
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany.
| | - A Bebersdorf
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany
| | - C Albrecht
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany
| | - J Manhart
- Institute of Legal Medicine, Rostock University Medical Center, Rostock, Germany
| | - E Caglayan
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany
| | - A Öner
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany
| | - H Ince
- Department of Cardiology, University Hospital Rostock, Ernst-Heydemann-Str. 6, 18057, Rostock, Germany
| | - J Ortak
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany
| | - A Büttner
- Institute of Legal Medicine, Rostock University Medical Center, Rostock, Germany
| | - E Safak
- Department of Cardiology, Vivantes Klinikum im Friedrichshain und Am Urban, Berlin, Germany
| |
Collapse
|