1
|
Jaafar N, Alsop DC. Arterial Spin Labeling: Key Concepts and Progress Towards Use as a Clinical Tool. Magn Reson Med Sci 2024; 23:352-366. [PMID: 38880616 PMCID: PMC11234948 DOI: 10.2463/mrms.rev.2024-0013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 05/15/2024] [Indexed: 06/18/2024] Open
Abstract
Arterial spin labeling (ASL), a non-invasive MRI technique, has emerged as a valuable tool for researchers that can measure blood flow and related parameters. This review aims to provide a qualitative overview of the technical principles and recent developments in ASL and to highlight its potential clinical applications. A growing literature demonstrates impressive ASL sensitivity to a range of neuropathologies and treatment responses. Despite its potential, challenges persist in the translation of ASL to widespread clinical use, including the lack of standardization and the limited availability of comprehensive training. As experience with ASL continues to grow, the final stage of translation will require moving beyond single site observational studies to multi-site experience and measurement of the added contribution of ASL to patient care and outcomes.
Collapse
Affiliation(s)
- Narjes Jaafar
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| | - David C. Alsop
- Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA, USA
| |
Collapse
|
2
|
Liao W, Shi G, Lv Y, Liu L, Tang X, Jin Y, Ning Z, Zhao X, Li X, Chen Z. Accurate and robust segmentation of cerebral vasculature on four-dimensional arterial spin labeling magnetic resonance angiography using machine-learning approach. Magn Reson Imaging 2024; 110:86-95. [PMID: 38631533 DOI: 10.1016/j.mri.2024.04.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 03/13/2024] [Accepted: 04/14/2024] [Indexed: 04/19/2024]
Abstract
Segmentation of cerebral vasculature on MR vascular images is of great significance for clinical application and research. However, the existing cerebrovascular segmentation approaches are limited due to insufficient image contrast and complicated algorithms. This study aims to explore the potential of the emerging four-dimensional arterial spin labeling magnetic resonance angiography (4D ASL-MRA) technique for fast and accurate cerebrovascular segmentation with a simple machine-learning approach. Nine temporal features were extracted from the intensity-time signal of each voxel, and eight spatial features from the neighboring voxels. Then, the unsupervised outlier detection algorithm, i.e. Isolation Forest, is used for segmentation of the vascular voxels based on the extracted features. The total length of the centerlines of the intracranial arterial vasculature, the dice similarity coefficient (DSC), and the average Hausdorff Distance (AVGHD) on the cross-sections of small- to large-sized vessels were calculated to evaluate the performance of the segmentation approach on 4D ASL-MRA of 18 subjects. Experiments show that the temporal information on 4D ASL-MRA can largely improve the segmentation performance. In addition, the proposed segmentation approach outperforms the traditional methods that were performed on the 3D image (i.e. the temporal average intensity projection of 4D ASL-MRA) and the previously proposed frame-wise approach. In conclusion, this study demonstrates that accurate and robust segmentation of cerebral vasculature is achievable on 4D ASL-MRA by using a simple machine-learning approach with appropriate features.
Collapse
Affiliation(s)
- Weibin Liao
- School of Computer Science and Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Gen Shi
- School of Computer Science and Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Yi Lv
- School of Computer Science and Technology, Beijing Institute of Technology, Beijing 100081, China
| | - Lixin Liu
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai 200433, China
| | - Xihe Tang
- Department of Neurosurgery, Aviation General Hospital of China Medical University, Beijing 100012, China
| | - Yongjian Jin
- Department of Neurosurgery, Aviation General Hospital of China Medical University, Beijing 100012, China
| | - Zihan Ning
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xihai Zhao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xuesong Li
- School of Computer Science and Technology, Beijing Institute of Technology, Beijing 100081, China.
| | - Zhensen Chen
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai 200433, China; Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence (Fudan University), Ministry of Education, Beijing 200433, China.
| |
Collapse
|
3
|
Entelmann W, Lindner T, Nawka MT, Fiehler J, Jansen O, Huhndorf M. Hybrid dynamic bright and black blood angiography by non-contrast-enhanced vessel selective saturation angiography. Magn Reson Imaging 2024; 108:22-28. [PMID: 38309377 DOI: 10.1016/j.mri.2024.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/05/2024]
Abstract
The integrity of vessel walls and changes in blood flow are involved in many diseases, and information about these anatomical and physiological conditions is important for a diagnosis. There are several different angiography methods that can be used to generate images for diagnostic purposes, but often using different imaging techniques and MR sequences. The purpose of this study was to develop a method that allows time-resolved, vessel-selective simultaneous bright and black blood imaging by vesselselective blood saturation. Measurements in six volunteers were performed to evaluate the time-resolved bright blood angiography and the significance of the generated black blood contrast. It was shown that this method can be used to generate a black blood contrast with a sufficient signal difference to the surrounding gray matter in addition to the time-resolved and vessel-selective bright blood contrast. Using post-processing methods, whole brain angiograms can be calculated from the acquired data.
Collapse
Affiliation(s)
- Wiebke Entelmann
- University Medical Center Hamburg-Eppendorf, Department of Neuroradiology, Germany.
| | - Thomas Lindner
- University Medical Center Hamburg-Eppendorf, Department of Neuroradiology, Germany.
| | - Marie Teresa Nawka
- University Medical Center Hamburg-Eppendorf, Department of Neuroradiology, Germany.
| | - Jens Fiehler
- University Medical Center Hamburg-Eppendorf, Department of Neuroradiology, Germany.
| | - Olav Jansen
- University Medical Center Schleswig-Holstein, Clinic of Radiology and Neuroradiology, Germany.
| | - Monika Huhndorf
- University Medical Center Schleswig-Holstein, Clinic of Radiology and Neuroradiology, Germany.
| |
Collapse
|
4
|
Yogi A, Ito J, Ishikawa K, Heianna J, Sakugawa S, Aguni N, Obara M, Maeda H, Nishie A. The effect of arterial spin labeling MR angiography (ASL-MRA) in visualizing the branches of external carotid artery. Sci Rep 2024; 14:4490. [PMID: 38396152 PMCID: PMC10891102 DOI: 10.1038/s41598-024-55018-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Accepted: 02/19/2024] [Indexed: 02/25/2024] Open
Abstract
This study aimed to assess the performance of arterial-spin labeling MRA (ASL-MRA) for visualizing the external carotid artery (ECA) branches in comparison with time-of-flight MRA (TOF-MRA) and CT angiography (CTA). We retrospectively selected 31 consecutive patients, who underwent both MRAs and CTA, prior to the intra-arterial chemoradiotherapy (IACRT) for head and neck cancer. Four patients underwent IACRT bilaterally, so we analyzed 35 ECAs. Pseudo-continuous, three-dimensional ASL using a turbo field echo sequence was acquired. For the TOF-MRA and CTA, clinically used parameters were applied. Two observers evaluated each ECA branch with reference to the angiogram at the IACRT, using five-point scale, in consensus. Friedman test for multiple comparisons was applied. ASL-MRA and CTA better visualized the superior thyroid, lingual, facial, submental, transverse facial, and internal maxillary arteries (IMAs) better than TOF-MRA (p < 0.05). In addition, CTA was superior to ASL-MRA in visualizing only submental artery among these arteries (p = 0.0005). Alternatively, the ASL-MRA was superior for visualizing the middle meningeal artery (MMA) and IMA, compared to the CTA (p = 0.0001 and 0.0007, respectively). ASL-MRA was superior to the TOF-MRA and similar to the CTA in visualizing most of ECA branches. Furthermore, ASL-MRA can better visualize the periphery of MMA and IMA than CTA.
Collapse
Affiliation(s)
- Akira Yogi
- Department of Radiology, University of the Ryukyus Hospital, 207 Uehara, Nishihara-Cho, , Nakagami-Gun, Okinawa, 903-0125, Japan.
| | - Junji Ito
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishihara-Cho, Nakagami-Gun, Okinawa, 903-0215, Japan
| | - Kazuki Ishikawa
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishihara-Cho, Nakagami-Gun, Okinawa, 903-0215, Japan
| | - Joichi Heianna
- Department of Radiology, University of the Ryukyus Hospital, 207 Uehara, Nishihara-Cho, , Nakagami-Gun, Okinawa, 903-0125, Japan
- Department of Radiology, Nanbu Tokushukai Hospital, 171-1 Hokama Yaese-Cho, Shimajiri-Gun, Okinawa, 901-0493, Japan
| | - Satoshi Sakugawa
- Department of Radiology, University of the Ryukyus Hospital, 207 Uehara, Nishihara-Cho, , Nakagami-Gun, Okinawa, 903-0125, Japan
| | - Narihisa Aguni
- Department of Radiology, University of the Ryukyus Hospital, 207 Uehara, Nishihara-Cho, , Nakagami-Gun, Okinawa, 903-0125, Japan
| | - Makoto Obara
- Philips Japan Healthcare, 13-37, Kohnan 2-Chome, Minato-Ku, Tokyo, Japan
| | - Hiroyuki Maeda
- Department of Otorhinolaryngology, Head and Neck Surgery, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishihara-Cho, Nakagami-Gun, Okinawa, 903-0215, Japan
| | - Akihiro Nishie
- Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishihara-Cho, Nakagami-Gun, Okinawa, 903-0215, Japan
| |
Collapse
|
5
|
Li YT, Bai K, Li GZ, Hu B, Chen JW, Shang YX, Yu Y, Chen ZH, Zhang C, Yan LF, Cui GB, Lu LJ, Wang W. Functional to structural plasticity in unilateral sudden sensorineural hearing loss: neuroimaging evidence. Neuroimage 2023; 283:120437. [PMID: 37924896 DOI: 10.1016/j.neuroimage.2023.120437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 10/29/2023] [Accepted: 10/30/2023] [Indexed: 11/06/2023] Open
Abstract
A cortical plasticity after long-duration single side deafness (SSD) is advocated with neuroimaging evidence while little is known about the short-duration SSDs. In this case-cohort study, we recruited unilateral sudden sensorineural hearing loss (SSNHL) patients and age-, gender-matched health controls (HC), followed by comprehensive neuroimaging analyses. The primary outcome measures were temporal alterations of varied dynamic functional network connectivity (dFNC) states, neurovascular coupling (NVC) and brain region volume at different stages of SSNHL. The secondary outcome measures were pure-tone audiograms of SSNHL patients before and after treatment. A total of 38 SSNHL patients (21 [55%] male; mean [standard deviation] age, 45.05 [15.83] years) and 44 HC (28 [64%] male; mean [standard deviation] age, 43.55 [12.80] years) were enrolled. SSNHL patients were categorized into subgroups based on the time from disease onset to the initial magnetic resonance imaging scan: early- (n = 16; 1-6 days), intermediate- (n = 9; 7-13 days), and late- stage (n = 13; 14-30 days) groups. We first identified slow state transitions between varied dFNC states at early-stage SSNHL, then revealed the decreased NVC restricted to the auditory cortex at the intermediate- and late-stage SSNHL. Finally, a significantly decreased volume of the left medial superior frontal gyrus (SFGmed) was observed only in the late-stage SSNHL cohort. Furthermore, the volume of the left SFGmed is robustly correlated with both disease duration and patient prognosis. Our study offered neuroimaging evidence for the evolvement from functional to structural brain alterations of SSNHL patients with disease duration less than 1 month, which may explain, from a neuroimaging perspective, why early-stage SSNHL patients have better therapeutic responses and hearing recovery.
Collapse
Affiliation(s)
- Yu-Ting Li
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Ke Bai
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Gan-Ze Li
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Bo Hu
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Jia-Wei Chen
- Department of Otolaryngology Head and Neck Surgery, Tangdu Hospital, Fourth Military Medical University, Xi'an 710038, China.
| | - Yu-Xuan Shang
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Ying Yu
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Zhu-Hong Chen
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Chi Zhang
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Lin-Feng Yan
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Guang-Bin Cui
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| | - Lian-Jun Lu
- Department of Otolaryngology Head and Neck Surgery, Tangdu Hospital, Fourth Military Medical University, Xi'an 710038, China.
| | - Wen Wang
- Department of Radiology, Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Fourth Military Medical University, 569 Xinsi Road, Xi'an 710038, Shaanxi, China.
| |
Collapse
|
6
|
Togao O, Obara M, Yamashita K, Kikuchi K, Wada T, Murazaki H, Arimura K, Nishimura A, Horie N, van de Ven K, Van Cauteren M, Ishigami K. Arterial Spin Labeling-Based MR Angiography for Cerebrovascular Diseases: Principles and Clinical Applications. J Magn Reson Imaging 2023. [PMID: 37937684 DOI: 10.1002/jmri.29119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 10/23/2023] [Accepted: 10/23/2023] [Indexed: 11/09/2023] Open
Abstract
Arterial spin labeling (ASL) is a noninvasive imaging technique that labels the proton spins in arterial blood and uses them as endogenous tracers. Brain perfusion imaging with ASL is becoming increasingly common in clinical practice, and clinical applications of ASL for intracranial magnetic resonance angiography (MRA) have also been demonstrated. Unlike computed tomography (CT) angiography and cerebral angiography, ASL-based MRA does not require contrast agents. ASL-based MRA overcomes most of the disadvantages of time-of-flight (TOF) MRA. Several schemes have been developed for ASL-based MRA; the most common method has been pulsed ASL, but more recently pseudo-continuous ASL, which provides a higher signal-to-noise ratio (SNR), has been used more frequently. New methods that have been developed include direct intracranial labeling methods such as velocity-selective ASL and acceleration-selective ASL. MRA using an extremely short echo time (eg, silent MRA) or ultrashort echo-time (TE) MRA can suppress metal susceptibility artifacts and is ideal for patients with a metallic device implanted in a cerebral vessel. Vessel-selective 4D ASL MRA can provide digital subtraction angiography (DSA)-like images. This review highlights the principles, clinical applications, and characteristics of various ASL-based MRA techniques. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Osamu Togao
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | | | - Koji Yamashita
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Kazufumi Kikuchi
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koichi Arimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Ataru Nishimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Nobutaka Horie
- Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan
| | | | | | - Kousei Ishigami
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| |
Collapse
|
7
|
Uetani H, Kitajima M, Ohmori Y, Morita K, Yamashita Y, Kaku Y, Nakaura T, Sasao A, Sasaki G, Ishiuchi S, Mukasa A, Hirai T. Intracranial aneurysms treated with stent-assisted coil embolization: evaluation with four-dimensional ultrashort-TE MR angiography. Eur Radiol 2023; 33:7923-7933. [PMID: 37284863 DOI: 10.1007/s00330-023-09755-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/23/2023] [Accepted: 03/10/2023] [Indexed: 06/08/2023]
Abstract
OBJECTIVES As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.
Collapse
Affiliation(s)
- Hiroyuki Uetani
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan.
| | - Mika Kitajima
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
- Department of Medical Image Sciences, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Yuki Ohmori
- Department of Neurosurgery, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Kosuke Morita
- Central Radiology Section, Kumamoto University Hospital, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Yuichi Yamashita
- Canon Medical Systems Corporation, MRI Sales Department, Sales Engineer Group, 70-1, Yanagi-cho, Saiwai-ku, Kawasaki, Kanagawa, 212-0015, Japan
| | - Yasuyuki Kaku
- Department of Neurosurgery, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Takeshi Nakaura
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Akira Sasao
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
- Joint Research Course of Imaging Dynamics Applied Medicine, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Goh Sasaki
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Soichiro Ishiuchi
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Akitake Mukasa
- Department of Neurosurgery, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| | - Toshinori Hirai
- Departments of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1, Honjo, Chuou-ku, Kumamoto, Japan
| |
Collapse
|
8
|
Panda A, Francois CJ, Bookwalter CA, Chaturvedi A, Collins JD, Leiner T, Rajiah PS. Non-Contrast Magnetic Resonance Angiography: Techniques, Principles, and Applications. Magn Reson Imaging Clin N Am 2023; 31:337-360. [PMID: 37414465 DOI: 10.1016/j.mric.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Several non-contrast magnetic resonance angiography (MRA) techniques have been developed, providing an attractive alternative to contrast-enhanced MRA and a radiation-free alternative to computed tomography (CT) CT angiography. This review describes the physical principles, limitations, and clinical applications of bright-blood (BB) non-contrast MRA techniques. The principles of BB MRA techniques can be broadly divided into (a) flow-independent MRA, (b) blood-inflow-based MRA, (c) cardiac phase dependent, flow-based MRA, (d) velocity sensitive MRA, and (e) arterial spin-labeling MRA. The review also includes emerging multi-contrast MRA techniques that provide simultaneous BB and black-blood images for combined luminal and vessel wall evaluation.
Collapse
Affiliation(s)
- Ananya Panda
- Department of Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | | | | | - Abhishek Chaturvedi
- Department of Radiology, University of Rochester Medical Center, Rochester, NY, USA
| | | | - Tim Leiner
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
9
|
Okell TW, Chiew M. Optimization of 4D combined angiography and perfusion using radial imaging and arterial spin labeling. Magn Reson Med 2023; 89:1853-1870. [PMID: 36533868 PMCID: PMC10952652 DOI: 10.1002/mrm.29558] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 11/27/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE To extend and optimize a non-contrast MRI technique to obtain whole head 4D (time-resolved 3D) qualitative angiographic and perfusion images from a single scan. METHODS 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) uses pseudocontinuous labeling with a 3D golden ratio ("koosh ball") readout to continuously image the blood water as it travels through the arterial system and exchanges into the tissue. High spatial/temporal resolution angiograms and low spatial/temporal resolution perfusion images can be flexibly reconstructed from the same raw k-space data. Constant and variable flip angle (CFA and VFA, respectively) excitation schedules were optimized through simulations and tested in healthy volunteers. A conventional sensitivity encoding (SENSE) reconstruction was compared against a locally low rank (LLR) reconstruction, which leverages spatiotemporal correlations. Comparison was also made with time-matched time-of-flight angiography and multi-delay EPI perfusion images. Differences in image quality were assessed through split-scan repeatability. RESULTS The optimized VFA schedule (2-9°) resulted in a significant (p < 0.001) improvement in image quality (up to 84% vs. CFA), particularly for the lower SNR perfusion images. The LLR reconstruction provided effective denoising without biasing the signal timecourses, significantly improving angiographic and perfusion image quality and repeatability (up to 143%, p < 0.001). 4D CAPRIA performed well compared with time-of-flight angiography and had better perfusion signal repeatability than the EPI-based approach (p < 0.001). CONCLUSION 4D CAPRIA optimized using a VFA schedule and LLR reconstruction can yield high quality whole head 4D angiograms and perfusion images from a single scan.
Collapse
Affiliation(s)
- Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| |
Collapse
|
10
|
Woods JG, Schauman SS, Chiew M, Chappell MA, Okell TW. Time-encoded pseudo-continuous arterial spin labeling: Increasing SNR in ASL dynamic angiography. Magn Reson Med 2023; 89:1323-1341. [PMID: 36255158 PMCID: PMC10091734 DOI: 10.1002/mrm.29491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 08/28/2022] [Accepted: 09/23/2022] [Indexed: 02/01/2023]
Abstract
PURPOSE Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the SNR improvements from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. METHODS The SNR of a conventional protocol with nine Look-Locker readouts and a 4 × $$ \times $$ 3 time-encoded protocol with three Look-Locker readouts (giving nine matched timepoints) were compared using simulations and in vivo data. Both protocols were compared using readouts with constant flip angles (CFAs) and variable flip angles (VFAs), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. RESULTS The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared with CFAs by 25% and 21% for the conventional and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest that optimizing the background suppression could improve in vivo SNR by a further 16%. CONCLUSIONS Time encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles, which can double the SNR compared with a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.
Collapse
Affiliation(s)
- Joseph G Woods
- Wellcome Centre for Integrated Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom
| | - S Sophie Schauman
- Wellcome Centre for Integrated Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom.,Department of Radiology, Stanford University, Stanford, California, USA
| | - Mark Chiew
- Wellcome Centre for Integrated Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom
| | - Michael A Chappell
- Wellcome Centre for Integrated Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom.,Mental Health and Clinical Neurosciences, School of Medicine, University of Nottingham, Nottingham, United Kingdom.,Sir Peter Mansfield Imaging Centre, School of Medicine, University of Nottingham, Nottingham, United Kingdom.,Nottingham Biomedical Research Centre, Queen's Medical Centre, University of Nottingham, Nottingham, United Kingdom
| | - Thomas W Okell
- Wellcome Centre for Integrated Neuroimaging, FMRIB, Nuffield Department of Clinical Neuroscience, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
11
|
Roumi A, Ben Hassen W, Hmeydia G, Posener S, Pallud J, Sharshar T, Calvet D, Mas JL, Baron JC, Oppenheim C, Naggara O, Turc G. Diagnostic performance of dynamic 3D magnetic resonance angiography in daily practice for the detection of intracranial arteriovenous shunts in patients with non-traumatic intracranial hemorrhage. Front Neurol 2023; 13:1085806. [PMID: 36776575 PMCID: PMC9911434 DOI: 10.3389/fneur.2022.1085806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 12/19/2022] [Indexed: 01/28/2023] Open
Abstract
Introduction Identification of treatable causes of intracranial hemorrhage (ICH) such as intracranial arteriovenous shunt is crucial to prevent recurrence. However, diagnostic approaches vary considerably across centers, partly because of limited knowledge of the diagnostic performance of first-line vascular imaging techniques. We assessed the diagnostic performance of dynamic three-dimensional magnetic resonance angiography (dynamic 3D MRA) in daily practice to detect intracranial arteriovenous shunts in ICH patients against subsequent digital subtraction angiography (DSA) as reference standard. Methods We reviewed all adult patients who underwent first-line dynamic 3D MRA and subsequent DSA for non-traumatic ICH between January 2016 and September 2021 in a tertiary center. Sensitivity, specificity, accuracy, positive and negative predictive values of dynamic 3D MRA for the detection of intracranial arteriovenous shunt were calculated with DSA as reference standard. Results Among 104 included patients, 29 (27.9%) had a DSA-confirmed arteriovenous shunt [19 pial arteriovenous malformations, 10 dural arteriovenous fistulae; median onset-to-DSA: 17 (IQR: 3-88) days]. The sensitivity and specificity of dynamic 3D MRA [median onset-to-dynamic 3D MRA: 14 (3-101) h] for the detection of intracranial arteriovenous shunt were 66% (95% CI: 48-83) and 91% (95% CI: 84-97), respectively. The corresponding accuracy, positive and negative predictive values were 84% (95% CI: 77-91), 73% (95% CI: 56-90), and 87% (95% CI: 80-95), respectively. Conclusion This study suggests that although first-line evaluation with dynamic 3D MRA may be helpful for the detection of intracranial arteriovenous shunts in patients with ICH, additional vascular imaging work-up should not be withheld if dynamic 3D MRA is negative. Comparative prospective studies are needed to determine the best imaging strategy to diagnose arteriovenous shunts after non-traumatic ICH.
Collapse
Affiliation(s)
- Arnaud Roumi
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Wagih Ben Hassen
- Neuroradiology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Ghazi Hmeydia
- Neuroradiology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Sacha Posener
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Johan Pallud
- Neurosurgery Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Tarek Sharshar
- Neuro-Intensive Care Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - David Calvet
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Jean-Louis Mas
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Jean-Claude Baron
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Catherine Oppenheim
- Neuroradiology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Olivier Naggara
- Neuroradiology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France
| | - Guillaume Turc
- Neurology Department, GHU Paris Psychiatrie et Neurosciences, Institut de Psychiatrie et Neurosciences de Paris, INSERM U1266, Université Paris Cité, FHU Neurovasc, Paris, France,*Correspondence: Guillaume Turc ✉
| |
Collapse
|
12
|
Hernandez‐Garcia L, Aramendía‐Vidaurreta V, Bolar DS, Dai W, Fernández‐Seara MA, Guo J, Madhuranthakam AJ, Mutsaerts H, Petr J, Qin Q, Schollenberger J, Suzuki Y, Taso M, Thomas DL, van Osch MJP, Woods J, Zhao MY, Yan L, Wang Z, Zhao L, Okell TW. Recent Technical Developments in ASL: A Review of the State of the Art. Magn Reson Med 2022; 88:2021-2042. [PMID: 35983963 PMCID: PMC9420802 DOI: 10.1002/mrm.29381] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Revised: 05/31/2022] [Accepted: 06/18/2022] [Indexed: 12/11/2022]
Abstract
This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple-timepoint ASL, body ASL, and clinical ASL recommendations.
Collapse
Affiliation(s)
| | | | - Divya S. Bolar
- Center for Functional Magnetic Resonance Imaging, Department of RadiologyUniversity of California at San DiegoSan DiegoCaliforniaUSA
| | - Weiying Dai
- Department of Computer ScienceState University of New York at BinghamtonBinghamtonNYUSA
| | | | - Jia Guo
- Department of BioengineeringUniversity of California RiversideRiversideCaliforniaUSA
| | | | - Henk Mutsaerts
- Department of Radiology & Nuclear MedicineAmsterdam University Medical Center, Amsterdam NeuroscienceAmsterdamThe Netherlands
| | - Jan Petr
- Helmholtz‐Zentrum Dresden‐RossendorfInstitute of Radiopharmaceutical Cancer ResearchDresdenGermany
| | - Qin Qin
- The Russell H. Morgan Department of Radiology and Radiological ScienceJohns Hopkins UniversityBaltimoreMarylandUSA
| | | | - Yuriko Suzuki
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
| | - Manuel Taso
- Division of MRI research, RadiologyBeth Israel Deaconess Medical Center and Harvard Medical SchoolBostonMassachusettsUSA
| | - David L. Thomas
- Department of Brain Repair and RehabilitationUCL Queen Square Institute of NeurologyLondonUnited Kingdom
| | - Matthias J. P. van Osch
- C.J. Gorter Center for high field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Joseph Woods
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
- Department of RadiologyUniversity of CaliforniaLa JollaCaliforniaUSA
| | - Moss Y. Zhao
- Department of RadiologyStanford UniversityStanfordCaliforniaUSA
| | - Lirong Yan
- Department of Radiology, Feinberg School of MedicineNorthwestern UniversityChicagoIllinoisUSA
| | - Ze Wang
- Department of Diagnostic Radiology and Nuclear MedicineUniversity of Maryland School of MedicineBaltimoreMarylandUSA
| | - Li Zhao
- Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument ScienceZhejiang UniversityZhejiangPeople's Republic of China
| | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
| |
Collapse
|
13
|
Wang M, Ma Y, Chen F, Zhou F, Zhang J, Zhang B. Acceleration of pCASL-Based Cerebral 4D MR Angiography Using Compressed SENSE: A Comparison With SENSE. Front Neurol 2022; 13:796271. [PMID: 35386411 PMCID: PMC8977489 DOI: 10.3389/fneur.2022.796271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Accepted: 02/22/2022] [Indexed: 11/19/2022] Open
Abstract
Objectives The objectives of this study were to accelerate the non-contrast-enhanced four-dimensional magnetic resonance angiography (4D MRA) based on pseudocontinuous arterial spin labeling combined with the Keyhole and View-sharing (4D-PACK) procedure using the Compressed SENSE (C-SENSE) and to improve intracranial vasculopathy evaluations for clinical purposes. Methods 4D-PACK acquisition with different C-SENSE and SENSE acceleration factors was performed on 29 healthy volunteers and six patients by means of a 3.0 T MR system. Two radiologists used a 4-grade scale to qualitatively assess the vessel visualization of the middle cerebral artery (MCA) and used a 5-grade scale to qualitatively examine the image quality of 4D-PACK axial source images. Interobserver agreement was assessed by determining the weighted kappa statistic. The contrast-to-noise ratio (CNR) and arterial transmit time (ATT) were calculated in four segments of the MCA. The repeated measures one-way ANOVA for CNR and the Friedman test for source images and vessel visualization were used to analyse the differences in five sequences. Results (1) At the M4 segment, C-SENSE5 acquisition (scores, 2.72 ± 0.53) and C-SENSE6.5 (scores, 2.55 ± 0.57) provided similar vessel visualization compared with SENSE4.5 (scores, 2.72 ± 0.46); however, C-SENSE8 (scores, 1.79 ± 0.49) and C-SENSE10 (scores, 1.52 ± 0.51) had lower scores (P < 0.050). (2) The source image quality of C-SENSE5 (scores, 4.55 ± 0.51), C-SENSE6.5 (scores, 4.03 ± 0.33), and C-SENSE8 (scores, 3.48 ± 0.51) acquisition was higher than that of SENSE4.5 (scores, 3.07 ± 0.26) (P < 0.001). (3) CNRs of different MCA segments for C-SENSE5 and C-SENSE6.5 acquisitions were not significantly different compared with that of SENSE4.5 acquisition. However, the CNRs were significantly lower for C-SENSE8 (M1: 45.85 ± 13.91, M2: 27.08 ± 9.92, M4: 7.93 ± 4.49) and C-SENSE10 (M1: 37.94 ± 9.92, M2: 23.51 ± 9.0, M4: 6.78 ± 4.12) than for SENSE4.5 (M1: 55.49 ± 13.39, M2: 36.94 ± 11.02, M4: 10.18 ± 5.15) in each corresponding segment (P < 0.050). ATTs in all MCA segments within different accelerating C-SENSE factors were obviously correlated with SENSE4.5. Conclusion C-SENSE6.5 acquisition could be used to evaluate both the intracranial macrovascular and distal arteries, which could reduce the acquisition time by 18% (5 min 5 s) compared with SENSE4.5. Moreover, C-SENSE8 acquisition (37% acceleration, 3 min 54 s) could be used for routine screening and clinical diagnosis of intracranial macrovascular disease with balanced image quality.
Collapse
Affiliation(s)
- Maoxue Wang
- Department of Radiology, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China
| | - Yiming Ma
- Department of Radiology, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China
| | - Fei Chen
- Department of Radiology, The Yancheng School of Clinical Medicine of Nanjing Medical University, Yancheng, China
| | - Fei Zhou
- Department of Radiology, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China
| | | | - Bing Zhang
- Department of Radiology, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, China.,Institute of Brain Science, Nanjing University, Nanjing, China
| |
Collapse
|
14
|
Kitajima M, Uetani H. Arterial Spin Labeling for Pediatric Central Nervous System Diseases: Techniques and Clinical Applications. Magn Reson Med Sci 2022; 22:27-43. [PMID: 35321984 PMCID: PMC9849418 DOI: 10.2463/mrms.rev.2021-0118] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Dynamic susceptibility contrast (DSC) and arterial spin labeling (ASL) are techniques used to evaluate brain perfusion using MRI. DSC requires dynamic image acquisition with a rapid administration of gadolinium-based contrast agent. In contrast, ASL obtains brain perfusion information using magnetically labeled blood water as an endogenous tracer. For the evaluation of brain perfusion in pediatric neurological diseases, ASL has a significant advantage compared to DSC, CT, and single-photon emission CT/positron emission tomography because of the lack of radiation exposure and contrast agent administration. However, in ASL, optimization of several parameters, including the type of labeling, image acquisition, background suppression, and postlabeling delay, is required, because they have a significant effect on the quantification of cerebral blood flow (CBF).In this article, we first review recent technical developments of ASL and age-dependent physiological characteristics in pediatric brain perfusion. We then review the clinical implementation of ASL in pediatric neurological diseases, including vascular diseases, brain tumors, acute encephalopathy with biphasic seizure and late reduced diffusion (AESD), and migraine. In moyamoya disease, ASL can be used for brain perfusion and vessel assessment in pre- and post-treatment. In arteriovenous malformations, ASL is sensitive to detect small degrees of shunt. Furthermore, in vascular diseases, the implementation of ASL-based time-resolved MR angiography is described. In neoplasms, ASL-derived CBF has a high diagnostic accuracy for differentiation between low- and high-grade pediatric brain tumors. In AESD and migraine, ASL may allow for accurate early diagnosis and provide pathophysiological information.
Collapse
Affiliation(s)
- Mika Kitajima
- Department of Medical Imaging Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto, Kumamoto, Japan,Corresponding author: 4-24-1, Kuhonji, Chuo-ku, Kumamoto, Kumamoto 862-0976, Japan. Phone: +81-373-5483, Fax: +81-373-5519, E-mail:
| | - Hiroyuki Uetani
- Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Kumamoto, Japan
| |
Collapse
|
15
|
Togao O, Obara M, Kikuchi K, Helle M, Arimura K, Nishimura A, Wada T, Murazaki H, Van Cauteren M, Hiwatashi A, Ishigami K. Vessel-Selective 4D-MRA Using Superselective Pseudocontinuous Arterial Spin-Labeling with Keyhole and View-Sharing for Visualizing Intracranial Dural AVFs. AJNR Am J Neuroradiol 2022; 43:368-375. [PMID: 35241425 PMCID: PMC8910818 DOI: 10.3174/ajnr.a7426] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Accepted: 12/11/2021] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE An accurate assessment of the hemodynamics of an intracranial dural AVF is necessary for treatment planning. We aimed to investigate the utility of 4D-MRA based on superselective pseudocontinuous arterial spin-labeling with CENTRA-keyhole and view-sharing (4D-S-PACK) for the vessel-selective visualization of intracranial dural AVFs. MATERIALS AND METHODS We retrospectively analyzed the images of 21 patients (12 men and 9 women; mean age, 62.2 [SD,19.2] years) with intracranial dural AVFs, each of whom was imaged with DSA, 4D-S-PACK, and nonselective 4D-MRA based on pseudocontinuous arterial spin-labeling combined with CENTRA-keyhole and view-sharing (4D-PACK). The shunt location, venous drainage patterns, feeding artery identification, and Borden classification were evaluated by 2 observers using both MRA methods on separate occasions. Vessel selectivity was evaluated on 4D-S-PACK. RESULTS Shunt locations were correctly evaluated in all 21 patients by both observers on both MRA methods. With 4D-S-PACK, observers 1 and 2 detected 76 (80.0%, P < .001) and 73 (76.8%, P < .001) feeding arteries of the 95 feeding arteries identified on DSA but only 39 (41.1%) and 46 (48.4%) feeding arteries with nonselective 4D-PACK, respectively. Both observers correctly identified 10 of the 11 patients with cortical venous reflux confirmed by DSA with both 4D-S-PACK and 4D-PACK (sensitivity = 90.9%, specificity = 90.9% for each method), and they made accurate Borden classifications in 20 of the 21 patients (95.2%) on both MRA methods. Of the 84 vessel territories examined, vessel selectivity was graded 3 or 4 in 73 (91.2%) and 66 (88.0%) territories by observers 1 and 2, respectively. CONCLUSIONS 4D-S-PACK is useful for the identification of feeding arteries and accurate classifications of intracranial dural AVFs and can be a useful noninvasive clinical tool.
Collapse
Affiliation(s)
- O. Togao
- From the Departments of Molecular Imaging & Diagnosis (O.T.)
| | - M. Obara
- Philips Japan (M.O., M.V.C.), Tokyo, Japan
| | | | - M. Helle
- Philips Research (M.H.), Hamburg, Germany
| | - K. Arimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - A. Nishimura
- Neurosurgery (K.A., A.N.), Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - T. Wada
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - H. Murazaki
- Division of Radiology (T.W., H.M.), Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | | | | | | |
Collapse
|
16
|
Shimbo G, Echigo R, Takiguchi M. The use of 4-dimensional magnetic resonance angiography as a noninvasive procedure to diagnose subclavian steal syndrome in a dog. J Am Vet Med Assoc 2021; 259:1040-1042. [PMID: 34647481 DOI: 10.2460/javma.259.9.1040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
CASE DESCRIPTION A 5-year-old 4.1-kg (9.0-lb) spayed female Toy Poodle was referred because of a 6-month history of sporadic signs of neck pain. CLINICAL FINDINGS Diagnostic imaging with MRI and CT revealed a dilated radicular artery connecting the right and left vertebral arteries and causing mild compression of the spinal cord. The left subclavian artery caudal to the origin of the left vertebral artery was absent. Subclavian steal syndrome (SSS) was suspected. TREATMENT AND OUTCOME The owner declined surgical treatment; thus, the dog was treated conservatively with glucocorticoids and analgesics. Eight months later, the dog's clinical signs were unchanged but palliated with the administration of glucocorticoids and analgesics, and 4-dimensional (4-D) magnetic resonance angiography (MRA) revealed that the left vertebral artery received blood supply from the right vertebral artery through the dilated radicular artery and that the left vertebral artery caudal to this site had retrograde flow and drained into the left subclavian artery, confirming the diagnosis of SSS. The owner again declined surgery, and conservative treatment continued. The dog's condition was unchanged at the last follow-up communication 11 months after 4-D MRA. CLINICAL RELEVANCE Subclavian steal syndrome is an extremely rare condition in dogs, and our findings suggested that 4-D MRA could be used to definitively diagnose SSS in dogs.
Collapse
|
17
|
Abstract
Clinical MRI systems have continually improved over the years since their introduction in the 1980s. In MRI technical development, the developments in each MRI system component, including data acquisition, image reconstruction, and hardware systems, have impacted the others. Progress in each component has induced new technology development opportunities in other components. New technologies outside of the MRI field, for example, computer science, data processing, and semiconductors, have been immediately incorporated into MRI development, which resulted in innovative applications. With high performance computing and MR technology innovations, MRI can now provide large volumes of functional and anatomical image datasets, which are important tools in various research fields. MRI systems are now combined with other modalities, such as positron emission tomography (PET) or therapeutic devices. These hybrid systems provide additional capabilities. In this review, MRI advances in the last two decades will be considered. We will discuss the progress of MRI systems, the enabling technology, established applications, current trends, and the future outlook.
Collapse
Affiliation(s)
- Hiroyuki Kabasawa
- Department of Radiological Sciences, School of Health Sciences at Narita, International University of Health and Welfare
| |
Collapse
|
18
|
Chen Z, Zhou Z, Qi H, Chen H, Chu B, Hatsukami TS, Yuan C, Balu N. A novel sequence for simultaneous measurement of whole-brain static and dynamic MRA, intracranial vessel wall image, and T 1 -weighted structural brain MRI. Magn Reson Med 2020; 85:316-325. [PMID: 32738091 DOI: 10.1002/mrm.28431] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 06/08/2020] [Accepted: 06/23/2020] [Indexed: 11/08/2022]
Abstract
PURPOSE To propose a highly time-efficient imaging technique named improved simultaneous noncontrast angiography and intraplaque hemorrhage (iSNAP) for simultaneous assessment of lumen, vessel wall, and blood flow in intracranial arteries. METHODS iSNAP consists of pulsed arterial spin labeling preparations and 3D golden angle radial acquisition. Images were reconstructed by k-space weighted image contrast (KWIC) method with optimized data-sharing strategies. Dynamic MRA for blood flow assessment was obtained from iSNAP by reconstruction at multiple inversion times and image subtraction, static MRA by both image subtraction approach and phase-sensitive inversion recovery technique, and vessel wall images by both reconstruction at zero-crossing time-point of blood and phase-sensitive inversion recovery. A T1 -weighted brain MRI was also reconstructed from iSNAP. Preliminary comparison of iSNAP against the dedicated dynamic MRA sequence 4D-TRANCE, MRA/vessel wall imaging sequence SNAP, and vessel wall imaging sequence T1 -weighted VISTA was performed in healthy volunteers and patients. RESULTS iSNAP has whole-brain coverage and takes ~6.5 min. The dedicated reconstruction strategies are feasible for each iSNAP image contrast and beneficial for image SNR. iSNAP-dynamic MRA yields similar dynamic flow information as 4D-TRANCE and allows more flexible temporal resolution. The 2 types of iSNAP static MRA images complement each other in characterizing both proximal large arteries and distal small arteries. Depiction of vessel wall lesions in iSNAP vessel wall images is better than SNAP and may be similar to T1 -weighted VISTA, although the images are slightly blurred. CONCLUSION iSNAP provides a time-efficient evaluation of intracranial arteries and may have great potential for comprehensive assessment of intracranial vascular conditions using a single sequence.
Collapse
Affiliation(s)
- Zhensen Chen
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Zechen Zhou
- Philips Research North America, Cambridge, Massachusetts, USA
| | - Haikun Qi
- School of Biomedical Engineering & Imaging Science, King's College London, London, United Kingdom
| | - Huijun Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, People's Republic of China
| | - Baocheng Chu
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Thomas S Hatsukami
- Department of Surgery, University of Washington, Seattle, Washington, USA
| | - Chun Yuan
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Niranjan Balu
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
19
|
Togao O, Obara M, Helle M, Yamashita K, Kikuchi K, Momosaka D, Kikuchi Y, Nishimura A, Arimura K, Wada T, Murazaki H, Iihara K, Van Cauteren M, Hiwatashi A. Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics. Eur Radiol 2020; 30:6452-6463. [PMID: 32696254 DOI: 10.1007/s00330-020-07057-4] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/04/2020] [Accepted: 06/30/2020] [Indexed: 12/17/2022]
Abstract
OBJECTIVES To evaluate the usefulness of 4D-MR angiography based on super-selective pseudo-continuous ASL combined with keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization and to examine the ability of this technique to visualize brain arteriovenous malformations (AVMs). METHODS In this retrospective study, 15 patients (ten men and five women, mean age 44.0 ± 16.9 years) with brain AVMs were enrolled. All patients were imaged with 4D-PACK (non-selective), 4D-S-PACK, and digital subtraction angiography (DSA). Observers evaluated vessel selectivity, identification of feeding arteries and venous drainage patterns, visualization scores, and contrast-to-noise ratio (CNR) for each AVM component. Measurements were compared between the MR methods. RESULTS Vessel selectivity was graded 4 in 43/45 (95.6%, observer 1) and 42/45 (93.3%, observer 2) territories and graded 3 in two (observer 1) and three (observer 2) territories. The sensitivity and specificity for identification of feeding arteries for both observers was 88.9% and 100% on 4D-PACK, and 100% and 100% on 4D-S-PACK, respectively. For venous drainage, the sensitivity and specificity was 100% on both methods for observer 1. The sensitivity and specificity for observer 2 was 94.4% and 83.3% on 4D-PACK, and 94.4% and 91.7% on 4D-S-PACK, respectively. The CNRs at the timepoint of 1600 ms were slightly lower in 4D-S-PACK than in 4D-PACK for all AVM components (Feeding artery, p = .02; nidus, p = .001; and draining artery, p = .02). The visualization scores for both observers were not significantly different between 4D-PACK and 4D-S-PACK for all components. CONCLUSIONS 4D-S-PACK could be a useful non-invasive clinical tool for assessing hemodynamics in brain AVMs. KEY POINTS • The 4D-MR angiography based on super-selective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) enabled excellent vessel selectivity. • The 4D-S-PACK enabled the perfect identification of feeding arteries of brain arteriovenous malformation (AVM). • 4D-S-PACK could be a non-invasive clinical tool for assessing hemodynamics in brain AVMs.
Collapse
Affiliation(s)
- Osamu Togao
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Makoto Obara
- Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan
| | | | - Koji Yamashita
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Kazufumi Kikuchi
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Daichi Momosaka
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Yoshitomo Kikuchi
- Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Ataru Nishimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Koichi Arimura
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Tatsuhiro Wada
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Hiroo Murazaki
- Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
| | - Koji Iihara
- Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan
| | - Marc Van Cauteren
- Philips Japan, 13-37, Kohnan 2-chome, Minato-ku, Tokyo, 108-8507, Japan
| | - Akio Hiwatashi
- Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi Higashi-ku, Fukuoka, 812-8582, Japan.
| |
Collapse
|