1
|
Chiba D, Kanazawa Y, Miyati T, Harada M, Miyoshi M, Hayashi H, Haga A. Simplified assessment for chemical exchanged saturation transfer (CEST) imaging: local offset frequency and CEST effect. Radiol Phys Technol 2024; 17:93-102. [PMID: 37897684 DOI: 10.1007/s12194-023-00752-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/27/2023] [Accepted: 10/09/2023] [Indexed: 10/30/2023]
Abstract
The aim of this study is to develop a novel phantom for the evaluation of clinical CEST imaging settings, e.g., B0 and B1 field inhomogeneities, CEST contrast, and post-processing. We made a phantom composed of two slice sections: a grid section for local offset frequency evaluation and a sample section for CEST effect evaluation using different concentrations of an egg white albumin solution. On a 3 Tesla MR scanner, a phantom study was performed using CEST imaging; the mean B1 amplitudes were set at 1.2 and 1.9 µT, and CEST images with and without B0 corrections were acquired. Next, region of interest (ROI) analysis was performed for each slice. Then, CEST images with and without B0 corrections were compared at each B1 amplitude. The B0 corrected Z-spectrums at each local region in the grid section showed a shifting of the curve bottom to 0 ppm. Z-spectrum at B1 = 1.9 µT showed a broader curve shape than that at 1.2 µT. Moreover, MTRasym values at 3.5 ppm for each albumin sample at B1 = 1.9 µT were about two times higher than those at 1.2 µT. Our phantom enabled us to evaluate and optimize B0 inhomogeneity and the CEST effect at the B1 amplitude.
Collapse
Affiliation(s)
- Daiki Chiba
- Brain Attack Center Ota Memorial Hospital, 3-6-28 Okinogami, Fukuyama, Hiroshima, 7200825, Japan
| | - Yuki Kanazawa
- Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto-Cyo, Toksuhima, 7708503, Japan.
| | - Tosiaki Miyati
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5‑11‑80 Kodatsuno, Kanazawa, Ishikawa, 9200942, Japan
| | - Masafumi Harada
- Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto-Cyo, Toksuhima, 7708503, Japan
| | - Mitsuharu Miyoshi
- Global MR Clinical Solutions and Research Collaborations, GE HealthCare, 4-7-127 Asahigaoka, Hino, Tokyo, 1918503, Japan
| | - Hiroaki Hayashi
- Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5‑11‑80 Kodatsuno, Kanazawa, Ishikawa, 9200942, Japan
| | - Akihiro Haga
- Institute of Biomedical Sciences, Tokushima University Graduate School, 3-18-15 Kuramoto-Cyo, Toksuhima, 7708503, Japan
| |
Collapse
|
2
|
Wu X, Su T, Chen Y, Xu Z, Wang X, Hu G, Wang Y, Wong LM, Zhang Z, Zhang T, Jin Z. B1 Power Modification for Amide Proton Transfer Imaging in Parotid Glands: A Strategy for Image Quality Accommodation and Evaluation of Tumor Detection Feasibility. Cancers (Basel) 2024; 16:888. [PMID: 38473250 DOI: 10.3390/cancers16050888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/17/2024] [Accepted: 02/19/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND In the application of APTw protocols for evaluating tumors and parotid glands, inhomogeneity and hyperintensity artifacts have remained an obstacle. This study aimed to improve APTw imaging quality and evaluate the feasibility of difference B1 values to detect parotid tumors. METHODS A total of 31 patients received three APTw sequences to acquire 32 lesions and 30 parotid glands (one patient had lesions on both sides). Patients received T2WI and 3D turbo-spin-echo (TSE) APTw imaging on a 3.0 T scanner for three sequences (B1 = 2 μT, 1 μT, and 0.7 μT in APTw 1, 2, and 3, respectively). APTw image quality was evaluated using four-point Likert scales in terms of integrity and hyperintensity artifacts. Image quality was compared between the three sequences. An evaluable group and a trustable group were obtained for APTmean value comparison. RESULTS Tumors in both APT2 and APT3 had fewer hyperintensity artifacts than in APT1. With B1 values decreasing, tumors had less integrity in APTw imaging. APTmean values of tumors were higher than parotid glands in traditional APT1 sequence though not significant, while the APTmean subtraction value was significantly different. CONCLUSIONS Applying a lower B1 value could remove hyperintensity but could also compromise its integrity. Combing different APTw sequences might increase the feasibility of tumor detection.
Collapse
Affiliation(s)
- Xiaoqian Wu
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Tong Su
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Yu Chen
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Zhentan Xu
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Xiaoqi Wang
- Yangtze Delta Region Institute of Tsinghua University, Jiaxing 314006, China
| | - Geli Hu
- Department of Clinical and Technical Support, Philips Healthcare, Beijing 100600, China
| | - Yunting Wang
- Department of Stomatology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Lun M Wong
- Department of Imaging and Interventional Radiology, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong 999077, China
| | - Zhuhua Zhang
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Tao Zhang
- Department of Stomatology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| | - Zhengyu Jin
- Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China
| |
Collapse
|
3
|
Mehrabian H, Chan RW, Sahgal A, Chen H, Theriault A, Lam WW, Myrehaug S, Tseng CL, Husain Z, Detsky J, Soliman H, Stanisz GJ. Chemical Exchange Saturation Transfer MRI for Differentiating Radiation Necrosis From Tumor Progression in Brain Metastasis-Application in a Clinical Setting. J Magn Reson Imaging 2022; 57:1713-1725. [PMID: 36219521 DOI: 10.1002/jmri.28440] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 09/07/2022] [Accepted: 09/08/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND High radiation doses of stereotactic radiosurgery (SRS) for brain metastases (BM) can increase the likelihood of radiation necrosis (RN). Advanced MRI sequences can improve the differentiation between RN and tumor progression (TP). PURPOSE To use saturation transfer MRI methods including chemical exchange saturation transfer (CEST) and magnetization transfer (MT) to distinguish RN from TP. STUDY TYPE Prospective cohort study. SUBJECTS Seventy patients (median age 60; 73% females) with BM (75 lesions) post-SRS. FIELD STRENGTH/SEQUENCE 3-T, CEST imaging using low/high-power (saturation B1 = 0.52 and 2.0 μT), quantitative MT imaging using B1 = 1.5, 3.0, and 5.0 μT, WAter Saturation Shift Referencing (WASSR), WAter Shift And B1 (WASABI), T1 , and T2 mapping. All used gradient echoes except T2 mapping (gradient and spin echo). ASSESSMENT Voxel-wise metrics included: magnetization transfer ratio (MTR); apparent exchange-dependent relaxation (AREX); MTR asymmetry; normalized MT exchange rate and pool size product; direct water saturation peak width; and the observed T1 and T2 . Regions of interests (ROIs) were manually contoured on the post-Gd T1 w. The mean (of median ROI values) was compared between groups. Clinical outcomes were determined by clinical and radiologic follow-up or histopathology. STATISTICAL TESTS t-Test, univariable and multivariable logistic regression, receiver operating characteristic, and area under the curve (AUC) with sensitivity/specificity values with the optimal cut point using the Youden index, Akaike information criterion (AIC), Cohen's d. P < 0.05 with Bonferroni correction was considered significant. RESULTS Seven metrics showed significant differences between RN and TP. The high-power MTR showed the highest AUC of 0.88, followed by low-power MTR (AUC = 0.87). The combination of low-power CEST scans improved the separation compared to individual parameters (with an AIC of 70.3 for low-power MTR/AREX). Cohen's d effect size showed that the MTR provided the largest effect sizes among all metrics. DATA CONCLUSION Significant differences between RN and TP were observed based on saturation transfer MRI. EVIDENCE LEVEL 3 Technical Efficacy: Stage 2.
Collapse
Affiliation(s)
- Hatef Mehrabian
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Rachel W Chan
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Arjun Sahgal
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Hanbo Chen
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Aimee Theriault
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Wilfred W Lam
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada
| | - Sten Myrehaug
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Chia-Lin Tseng
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Zain Husain
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Jay Detsky
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Hany Soliman
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - Greg J Stanisz
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario, Canada.,Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.,Department of Neurosurgery and Pediatric Neurosurgery, Medical University of Lublin, Lublin, Poland
| |
Collapse
|
4
|
Wu Y, Wood TC, Arzanforoosh F, Hernandez-Tamames JA, Barker GJ, Smits M, Warnert EAH. 3D APT and NOE CEST-MRI of healthy volunteers and patients with non-enhancing glioma at 3 T. MAGMA (NEW YORK, N.Y.) 2022; 35:63-73. [PMID: 34994858 PMCID: PMC8901510 DOI: 10.1007/s10334-021-00996-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 12/17/2021] [Accepted: 12/23/2021] [Indexed: 11/28/2022]
Abstract
Objective Clinical application of chemical exchange saturation transfer (CEST) can be performed with investigation of amide proton transfer (APT) and nuclear Overhauser enhancement (NOE) effects. Here, we investigated APT- and NOE-weighted imaging based on advanced CEST metrics to map tumor heterogeneity of non-enhancing glioma at 3 T. Materials and methods APT- and NOE-weighted maps based on Lorentzian difference (LD) and inverse magnetization transfer ratio (MTRREX) were acquired with a 3D snapshot CEST acquisition at 3 T. Saturation power was investigated first by varying B1 (0.5–2 µT) in 5 healthy volunteers then by applying B1 of 0.5 and 1.5 µT in 10 patients with non-enhancing glioma. Tissue contrast (TC) and contrast-to-noise ratios (CNR) were calculated between glioma and normal appearing white matter (NAWM) and grey matter, in APT- and NOE-weighted images. Volume percentages of the tumor showing hypo/hyperintensity (VPhypo/hyper,CEST) in APT/NOE-weighted images were calculated for each patient. Results LD APT resulting from using a B1 of 1.5 µT was found to provide significant positive TCtumor,NAWM and MTRREX NOE (B1 of 1.5 µT) provided significant negative TCtumor,NAWM in tissue differentiation. MTRREX-based NOE imaging under 1.5 µT provided significantly larger VPhypo,CEST than MTRREX APT under 1.5 µT. Conclusion This work showed that with a rapid CEST acquisition using a B1 saturation power of 1.5 µT and covering the whole tumor, analysis of both LD APT and MTRREX NOE allows for observing tumor heterogeneity, which will be beneficial in future studies using CEST-MRI to improve imaging diagnostics for non-enhancing glioma.
Collapse
Affiliation(s)
- Yulun Wu
- Department of Radiology and Nuclear Medicine, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands. .,Brain Tumor Centre, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.
| | - Tobias C Wood
- Centre for Neuroimaging Science, King's College London, London, UK
| | - Fatemeh Arzanforoosh
- Department of Radiology and Nuclear Medicine, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.,Brain Tumor Centre, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Juan A Hernandez-Tamames
- Department of Radiology and Nuclear Medicine, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands
| | - Gareth J Barker
- Centre for Neuroimaging Science, King's College London, London, UK
| | - Marion Smits
- Department of Radiology and Nuclear Medicine, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands.,Brain Tumor Centre, Erasmus MC Cancer Institute, Rotterdam, The Netherlands
| | - Esther A H Warnert
- Department of Radiology and Nuclear Medicine, Erasmus MC, Dr. Molewaterplein 40, 3015 GD, Rotterdam, The Netherlands. .,Brain Tumor Centre, Erasmus MC Cancer Institute, Rotterdam, The Netherlands.
| |
Collapse
|
5
|
Abstract
Clinical MRI systems have continually improved over the years since their introduction in the 1980s. In MRI technical development, the developments in each MRI system component, including data acquisition, image reconstruction, and hardware systems, have impacted the others. Progress in each component has induced new technology development opportunities in other components. New technologies outside of the MRI field, for example, computer science, data processing, and semiconductors, have been immediately incorporated into MRI development, which resulted in innovative applications. With high performance computing and MR technology innovations, MRI can now provide large volumes of functional and anatomical image datasets, which are important tools in various research fields. MRI systems are now combined with other modalities, such as positron emission tomography (PET) or therapeutic devices. These hybrid systems provide additional capabilities. In this review, MRI advances in the last two decades will be considered. We will discuss the progress of MRI systems, the enabling technology, established applications, current trends, and the future outlook.
Collapse
Affiliation(s)
- Hiroyuki Kabasawa
- Department of Radiological Sciences, School of Health Sciences at Narita, International University of Health and Welfare
| |
Collapse
|
6
|
Yao J, Wang C, Ellingson BM. Influence of phosphate concentration on amine, amide, and hydroxyl CEST contrast. Magn Reson Med 2020; 85:1062-1078. [PMID: 32936483 DOI: 10.1002/mrm.28481] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 07/24/2020] [Accepted: 07/27/2020] [Indexed: 12/11/2022]
Abstract
PURPOSE To evaluate the influence of phosphate on amine, amide, and hydroxyl CEST contrast using Bloch-McConnell simulations applied to physical phantom data. METHODS Phantom solutions of 4 representative metabolites with exchangeable protons-glycine (α-amine protons), Cr (η-amine protons), egg white protein (amide protons), and glucose (hydroxyl protons)-were prepared at different pH levels (5.6 to 8.9) and phosphate concentrations (5 to 80 mM). CEST images of the phantom were collected with CEST-EPI sequence at 3 tesla. The CEST data were then fitted to full Bloch-McConnell equation simulations to estimate the exchange rate constants. With the fitted parameters, simulations were performed to evaluate the intracellular and extracellular contributions of CEST signals in normal brain tissue and brain tumors, as well as in dynamic glucose-enhanced experiments. RESULTS The exchange rates of α-amine and hydroxyl protons were found to be highly dependent on both pH and phosphate concentrations, whereas the exchange rates of η-amine and amide protons were pH-dependent, albeit not catalyzed by phosphate. With phosphate being predominantly intracellular, CEST contrast of α-amine exhibited a higher sensitivity to changes in the extracellular microenvironment. Simulations of dynamic glucose-enhanced signals demonstrated that the contrast between normal and tumor tissue was mostly due to the extracellular CEST effect. CONCLUSION The proton exchange rates in some metabolites can be greatly catalyzed by the presence of phosphate at physiological concentrations, which substantially alters the CEST contrast. Catalytic agents should be considered as confounding factors in future CEST-MRI research. This new dimension may also benefit the development of novel phosphate-sensitive imaging methods.
Collapse
Affiliation(s)
- Jingwen Yao
- UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers, University of California, Los Angeles, Los Angeles, California, USA.,Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California, USA.,Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, Los Angeles, California, USA
| | - Chencai Wang
- UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers, University of California, Los Angeles, Los Angeles, California, USA.,Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California, USA
| | - Benjamin M Ellingson
- UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers, University of California, Los Angeles, Los Angeles, California, USA.,Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California, USA.,Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles, Los Angeles, California, USA.,Department of Psychiatry and Biobehavioral Sciences, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, California, USA
| |
Collapse
|
7
|
Wang R, Chen P, Shen Z, Lin G, Xiao G, Dai Z, Zhang B, Chen Y, Lai L, Zong X, Li Y, Tang Y, Wu R. Brain Amide Proton Transfer Imaging of Rat With Alzheimer's Disease Using Saturation With Frequency Alternating RF Irradiation Method. Front Aging Neurosci 2019; 11:217. [PMID: 31507405 PMCID: PMC6713910 DOI: 10.3389/fnagi.2019.00217] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Accepted: 08/02/2019] [Indexed: 02/05/2023] Open
Abstract
Amyloid-β (Aβ) deposits and some proteins play essential roles in the pathogenesis of Alzheimer's disease (AD). Amide proton transfer (APT) imaging, as an imaging modality to detect tissue protein, has shown promising features for the diagnosis of AD disease. In this study, we chose 10 AD model rats as the experimental group and 10 sham-operated rats as the control group. All the rats underwent a Y-maze test before APT image acquisition, using saturation with frequency alternating RF irradiation (APTSAFARI) method on a 7.0 T animal MRI scanner. Compared with the control group, APT (3.5 ppm) values of brain were significantly reduced in AD models (p < 0.002). The APTSAFARI imaging is more significant than APT imaging (p < 0.0001). AD model mice showed spatial learning and memory loss in the Y-maze experiment. In addition, there was significant neuronal loss in the hippocampal CA1 region and cortex compared with sham-operated rats. In conclusion, we demonstrated that APT imaging could potentially provide molecular biomarkers for the non-invasive diagnosis of AD. APTSAFARI MRI could be used as an effective tool to improve the accuracy of diagnosis of AD compared with conventional APT imaging.
Collapse
Affiliation(s)
- Runrun Wang
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Peidong Chen
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Zhiwei Shen
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
- Philips Healthcare, Shantou, China
| | - Guisen Lin
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Gang Xiao
- Department of Mathematics and Statistics, Hanshan Normal University, Chaozhou, China
| | - Zhuozhi Dai
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Bingna Zhang
- Translational Medicine, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Yuanfeng Chen
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Lihua Lai
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Xiaodan Zong
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Yan Li
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Yanyan Tang
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
| | - Renhua Wu
- Department of Medical Imaging, The Second Affiliated Hospital, Shantou University Medical College, Shantou, China
- *Correspondence: Renhua Wu,
| |
Collapse
|
8
|
Lin G, Zhuang C, Shen Z, Xiao G, Chen Y, Shen Y, Zong X, Wu R. APT Weighted MRI as an Effective Imaging Protocol to Predict Clinical Outcome After Acute Ischemic Stroke. Front Neurol 2018; 9:901. [PMID: 30405523 PMCID: PMC6205981 DOI: 10.3389/fneur.2018.00901] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Accepted: 10/05/2018] [Indexed: 11/13/2022] Open
Abstract
To explore the capability of the amide-proton-transfer weighted (APTW) magnetic resonance imaging (MRI) in the evaluation of clinical neurological deficit at the time of hospitalization and assessment of long-term daily functional outcome for patients with acute ischemic stroke (AIS). We recruited 55 AIS patients with brain MRI acquired within 24-48 h of symptom onset and followed up with their 90-day modified Rankin Scale (mRS) score. APT weighted MRI was performed for all the study subjects to measure APTW signal quantitatively in the acute ischemic area (APTWipsi) and the contralateral side (APTWcont). Change of the APT signal between the acute ischemic region and the contralateral side (ΔAPTW) was calculated. Maximum APTW signal (APTWmax) and minimal APTW signal (APTWmin) were also acquired to demonstrate APTW signals heterogeneity (APTWmax-min). In addition, all the patients were divided into 2 groups according to their 90-day mRS score (good prognosis group with mRS score <2 and poor prognosis group with mRS score ≥2). In the meantime, ΔAPTW of these groups was compared. We found that ΔAPTW was in good correlation with National Institutes of Health Stroke Scale (NIHSS) score (R 2 = 0.578, p < 0.001) and 90-day mRS score (R 2 = 0.55, p < 0.001). There was significant difference of ΔAPTW between patients with good prognosis and patients with poor prognosis. Plus, APTWmax-min was significantly different between two groups. These results suggested that APT weighted MRI could be used as an effective tool to assess the stroke severity and prognosis for patients with AIS, with APTW signal heterogeneity as a possible biomarker.
Collapse
Affiliation(s)
- Guisen Lin
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Caiyu Zhuang
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Zhiwei Shen
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Gang Xiao
- Department of Mathematics and Statistics, Hanshan Normal University, Chaozhou, China
| | - Yanzi Chen
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Yuanyu Shen
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Xiaodan Zong
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China
| | - Renhua Wu
- Department of Medical Imaging, The Second Affiliated Hospital, Medical College of Shantou University, Shantou, China.,Provincial Key Laboratory of Medical Molecular Imaging, Shantou, China
| |
Collapse
|
9
|
Liu R, Jiang G, Gao P, Li G, Nie L, Yan J, Jiang M, Duan R, Zhao Y, Luo J, Yin Y, Li C. Non-invasive Amide Proton Transfer Imaging and ZOOM Diffusion-Weighted Imaging in Differentiating Benign and Malignant Thyroid Micronodules. Front Endocrinol (Lausanne) 2018; 9:747. [PMID: 30631303 PMCID: PMC6315121 DOI: 10.3389/fendo.2018.00747] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2018] [Accepted: 11/26/2018] [Indexed: 12/12/2022] Open
Abstract
Background: Pre-operative non-invasive differentiation of benign and malignant thyroid nodules is difficult for doctors. This study aims to determine whether amide proton transfer (APT) imaging and zonally oblique multi-slice (ZOOM) diffusion-weighted imaging (DWI) can provide increased accuracy in differentiating benign and malignant thyroid nodules. Methods: This retrospective study was approved by the institutional review board and included 60 thyroid nodules in 50 patients. All of the nodules were classified as malignant (n = 21) or benign (n = 39) based on pathology. It was meaningful to analyze the APT and apparent diffusion coefficient (ADC) values of the two groups by independent t-test to identify the benign and malignant thyroid nodules. The relationship between APT and ZOOM DWI was explored through Pearson correlation analysis. The diagnostic efficacy of APT and ZOOM DWI in determining if thyroid nodules were benign or malignant was compared using receiver operating characteristic (ROC) curve analysis. Results: The mean APTw value of the benign nodules was 2.99 ± 0.79, while that of the malignant nodules was 2.14 ± 0.73. Additionally, there was a significant difference in the APTw values of the two groups (P < 0.05). The mean ADC value of the benign nodules was 1.84 ± 0.41, and was significantly different from that of the malignant nodules, which was 1.21 ± 0.19 (P < 0.05). Scatter point and Pearson test showed a moderate positive correlation between the APT and ADC values (P < 0.05). The ROC curve showed that the area under the curve (AUC) value of ZOOM DWI (AUC = 0.937) was greater than that of APT (AUC = 0.783) (P = 0.028). Conclusion: APT and ZOOM DWI imaging improved the accuracy of distinguishing between benign and malignant thyroid nodules. ZOOM DWI is superior to APTw imaging (Z = 2.198, P < 0.05).
Collapse
Affiliation(s)
- Ruijian Liu
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Guihuang Jiang
- Department of Medical Imaging, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Peng Gao
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Guoming Li
- Department of Medical Imaging, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Linghui Nie
- Guangdong Traditional Medical and Sports Injury Rehabilitation Research Institute, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Jianhao Yan
- Department of Medical Imaging, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Min Jiang
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Renpeng Duan
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Yue Zhao
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Jinxian Luo
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Yi Yin
- Department of Medical Imaging, Guangdong Second Provincial General Hospital, Guangzhou, China
| | - Cheng Li
- Department of General Surgery, Guangdong Second Provincial General Hospital, Guangzhou, China
- Guangdong Traditional Medical and Sports Injury Rehabilitation Research Institute, Guangdong Second Provincial General Hospital, Guangzhou, China
- *Correspondence: Cheng Li
| |
Collapse
|