Benitez-Aurioles J, Clegg PS, Alcaide-Corral CJ, Wimberley C, Tavares AAS. Multi-organ kinetic modeling for Na[ 18F]F pre-clinical total-body PET studies. Med Phys 2024. [PMID: 39499788 DOI: 10.1002/mp.17499] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2024] [Revised: 09/20/2024] [Accepted: 10/11/2024] [Indexed: 11/07/2024] Open
Abstract
BACKGROUND Total-body positron emission tomography (PET), already well-established in the pre-clinical setting, makes it possible to study multi-parameters in biological systems as a whole, rather than focusing on single tissues analysis. Simultaneous kinetic analysis of multiple organs poses some daunting new challenges. PURPOSE To explore quantifying the pharmacokinetics of Na[18F]F in multiple dissimilar murine organs simultaneously in vivo with total-body PET imaging using different compartmental models for each organ and a shared cardiovascular system. METHODS Six mice underwent a 60-min total-body PET scan following intravenous bolus injection of Na[18F]F. Compartmental models were constructed for each organ (heart, lungs, liver, kidneys, and bone) using an image derived input function. Non-linear least squares fitting of a model that connects the five organs to a shared cardiovascular system was used to analyze both the first 3 min of data and the full hour. Analysis was repeated 5000 times using different initial parameter values for each duration, permitting analysis of correlations between parameters. RESULTS The models give a good qualitative account of the activity curves irrespective of the duration of the data; however, the quality of the fits to 3 min of data (averageχ ν 2 $\chi _\nu ^2$ is 2.72) was generally better. Comparison of perfusion values to literature values was possible for the liver and lungs with the former (liver, 0.540 ± 0.177 mL/ml/min) being well-above expectations and the latter (lungs, 0.184 ± 0.413 mL/ml/min) in rough agreement. Correlations between microparameter values (especially affecting k2) caused very noticeable problems for data modeling from both the kidneys and the femur. CONCLUSION The present study demonstrates an approach to performing kinetic modeling for multiple organs simultaneously with Na[18F]F. The observed correlations between microparameter values remain a challenge. Nonetheless, many microparameters can be estimated reliably with a quantitative analysis of perfusion being possible for some organs.
Collapse
Affiliation(s)
- Jose Benitez-Aurioles
- School of Physics & Astronomy, University of Edinburgh, Edinburgh, UK
- University of Manchester, Division of Informatics, Imaging and Data Science, Manchester, UK
| | - Paul S Clegg
- School of Physics & Astronomy, University of Edinburgh, Edinburgh, UK
| | - Carlos J Alcaide-Corral
- Edinburgh Imaging, University of Edinburgh, Edinburgh, UK
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| | - Catriona Wimberley
- School of Physics & Astronomy, University of Edinburgh, Edinburgh, UK
- Edinburgh Imaging, University of Edinburgh, Edinburgh, UK
- Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK
| | - Adriana A S Tavares
- Edinburgh Imaging, University of Edinburgh, Edinburgh, UK
- University/BHF Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, UK
| |
Collapse
|
2
|
Godbersen GM, Falb P, Klug S, Silberbauer LR, Reed MB, Nics L, Hacker M, Lanzenberger R, Hahn A. Non-invasive assessment of stimulation-specific changes in cerebral glucose metabolism with functional PET. Eur J Nucl Med Mol Imaging 2024; 51:2283-2292. [PMID: 38491215 PMCID: PMC11178598 DOI: 10.1007/s00259-024-06675-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Accepted: 03/02/2024] [Indexed: 03/18/2024]
Abstract
PURPOSE Functional positron emission tomography (fPET) with [18F]FDG allows quantification of stimulation-induced changes in glucose metabolism independent of neurovascular coupling. However, the gold standard for quantification requires invasive arterial blood sampling, limiting its widespread use. Here, we introduce a novel fPET method without the need for an input function. METHODS We validated the approach using two datasets (DS). For DS1, 52 volunteers (23.2 ± 3.3 years, 24 females) performed Tetris® during a [18F]FDG fPET scan (bolus + constant infusion). For DS2, 18 participants (24.2 ± 4.3 years, 8 females) performed an eyes-open/finger tapping task (constant infusion). Task-specific changes in metabolism were assessed with the general linear model (GLM) and cerebral metabolic rate of glucose (CMRGlu) was quantified with the Patlak plot as reference. We then estimated simplified outcome parameters, including GLM beta values and percent signal change (%SC), and compared them, region and whole-brain-wise. RESULTS We observed higher agreement with the reference for DS1 than DS2. Both DS resulted in strong correlations between regional task-specific beta estimates and CMRGlu (r = 0.763…0.912). %SC of beta values exhibited strong agreement with %SC of CMRGlu (r = 0.909…0.999). Average activation maps showed a high spatial similarity between CMRGlu and beta estimates (Dice = 0.870…0.979) as well as %SC (Dice = 0.932…0.997), respectively. CONCLUSION The non-invasive method reliably estimates task-specific changes in glucose metabolism without blood sampling. This streamlines fPET, albeit with the trade-off of being unable to quantify baseline metabolism. The simplification enhances its applicability in research and clinical settings.
Collapse
Affiliation(s)
- Godber Mathis Godbersen
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria
| | - Pia Falb
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria
| | - Sebastian Klug
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria
| | - Leo R Silberbauer
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria
| | - Murray Bruce Reed
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria
| | - Lukas Nics
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Marcus Hacker
- Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Rupert Lanzenberger
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria.
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria.
| | - Andreas Hahn
- Department of Psychiatry and Psychotherapy, Medical University of Vienna, Vienna, Austria.
- Comprehensive Center for Clinical Neurosciences and Mental Health (C3NMH), Medical University of Vienna, Vienna, Austria.
| |
Collapse
|
3
|
Palard-Novello X, Visser D, Tolboom N, Smith CLC, Zwezerijnen G, van de Giessen E, den Hollander ME, Barkhof F, Windhorst AD, van Berckel BN, Boellaard R, Yaqub M. Validation of image-derived input function using a long axial field of view PET/CT scanner for two different tracers. EJNMMI Phys 2024; 11:25. [PMID: 38472680 DOI: 10.1186/s40658-024-00628-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Accepted: 02/27/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Accurate image-derived input function (IDIF) from highly sensitive large axial field of view (LAFOV) PET/CT scanners could avoid the need of invasive blood sampling for kinetic modelling. The aim is to validate the use of IDIF for two kinds of tracers, 3 different IDIF locations and 9 different reconstruction settings. METHODS Eight [18F]FDG and 10 [18F]DPA-714 scans were acquired respectively during 70 and 60 min on the Vision Quadra PET/CT system. PET images were reconstructed using various reconstruction settings. IDIFs were taken from ascending aorta (AA), descending aorta (DA), and left ventricular cavity (LV). The calibration factor (CF) extracted from the comparison between the IDIFs and the manual blood samples as reference was used for IDIFs accuracy and precision assessment. To illustrate the effect of various calibrated-IDIFs on Patlak linearization for [18F]FDG and Logan linearization for [18F]DPA-714, the same target time-activity curves were applied for each calibrated-IDIF. RESULTS For [18F]FDG, the accuracy and precision of the IDIFs were high (mean CF ≥ 0.82, SD ≤ 0.06). Compared to the striatum influx (Ki) extracted using calibrated AA IDIF with the updated European Association of Nuclear Medicine Research Ltd. standard reconstruction (EARL2), Ki mean differences were < 2% using the other calibrated IDIFs. For [18F]DPA714, high accuracy of the IDIFs was observed (mean CF ≥ 0.86) except using absolute scatter correction, DA and LV (respectively mean CF = 0.68, 0.47 and 0.44). However, the precision of the AA IDIFs was low (SD ≥ 0.10). Compared to the distribution volume (VT) in a frontal region obtained using calibrated continuous arterial sampler input function as reference, VT mean differences were small using calibrated AA IDIFs (for example VT mean difference = -5.3% using EARL2), but higher using calibrated DA and LV IDIFs (respectively + 12.5% and + 19.1%). CONCLUSIONS For [18F]FDG, IDIF do not need calibration against manual blood samples. For [18F]DPA-714, AA IDIF can replace continuous arterial sampling for simplified kinetic quantification but only with calibration against arterial blood samples. The accuracy and precision of IDIF from LAFOV PET/CT system depend on tracer, reconstruction settings and IDIF VOI locations, warranting careful optimization.
Collapse
Affiliation(s)
- Xavier Palard-Novello
- Univ Rennes, CLCC Eugène Marquis, INSERM, LTSI - UMR 1099, Rennes, France.
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
| | - Denise Visser
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
| | | | - Charlotte L C Smith
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Gerben Zwezerijnen
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Elsmarieke van de Giessen
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
| | - Marijke E den Hollander
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Frederik Barkhof
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Queen Square Institute of Neurology and Centre for Medical Image Computing, University College London, London, UK
| | - Albert D Windhorst
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Bart Nm van Berckel
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
| | - Ronald Boellaard
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Maqsood Yaqub
- Amsterdam University Medical Center, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Amsterdam Neuroscience, Brain Imaging, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Wimberley C, Lavisse S, Hillmer A, Hinz R, Turkheimer F, Zanotti-Fregonara P. Kinetic modeling and parameter estimation of TSPO PET imaging in the human brain. Eur J Nucl Med Mol Imaging 2021; 49:246-256. [PMID: 33693967 PMCID: PMC8712306 DOI: 10.1007/s00259-021-05248-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Accepted: 02/07/2021] [Indexed: 12/12/2022]
Abstract
PURPOSE Translocator protein 18-kDa (TSPO) imaging with positron emission tomography (PET) is widely used in research studies of brain diseases that have a neuro-immune component. Quantification of TSPO PET images, however, is associated with several challenges, such as the lack of a reference region, a genetic polymorphism affecting the affinity of the ligand for TSPO, and a strong TSPO signal in the endothelium of the brain vessels. These challenges have created an ongoing debate in the field about which type of quantification is most useful and whether there is an appropriate simplified model. METHODS This review focuses on the quantification of TSPO radioligands in the human brain. The various methods of quantification are summarized, including the gold standard of compartmental modeling with metabolite-corrected input function as well as various alternative models and non-invasive approaches. Their advantages and drawbacks are critically assessed. RESULTS AND CONCLUSIONS Researchers employing quantification methods for TSPO should understand the advantages and limitations associated with each method. Suggestions are given to help researchers choose between these viable alternative methods.
Collapse
Affiliation(s)
| | - Sonia Lavisse
- CEA, CNRS, MIRCen, Laboratoire des Maladies Neurodégénératives, Université Paris-Saclay, 92265, Fontenay-aux-Roses, France
| | - Ansel Hillmer
- Departments of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA
- Departments of Psychiatry, Yale School of Medicine, New Haven, CT, USA
- Yale PET Center, Yale School of Medicine, New Haven, CT, USA
| | - Rainer Hinz
- Wolfson Molecular Imaging Centre, University of Manchester, Manchester, M20 3LJ, UK
| | - Federico Turkheimer
- Department of Neuroimaging, Institute of Psychiatry, Psychology and Neuroscience, Centre for Neuroimaging Sciences, King's College London, De Crespigny Park, London, SE5 8AF, UK
- MRC Centre for Neurodevelopmental Disorders, King's College London, London, SE1 1UL, UK
| | - Paolo Zanotti-Fregonara
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, MD, USA
| |
Collapse
|
5
|
Toufique Y, Bouhali O, Negre P, O' Doherty J. Simulation study of a coincidence detection system for non-invasive determination of arterial blood time-activity curve measurements. EJNMMI Phys 2020; 7:25. [PMID: 32383043 PMCID: PMC7205938 DOI: 10.1186/s40658-020-00297-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 04/22/2020] [Indexed: 01/03/2023] Open
Abstract
Background Arterial sampling in PET studies for the purposes of kinetic modeling remains an invasive, time-intensive, and expensive procedure. Alternatives to derive the blood time-activity curve (BTAC) non-invasively are either reliant on large vessels in the field of view or are laborious to implement and analyze as well as being prone to many processing errors. An alternative method is proposed in this work by the simulation of a non-invasive coincidence detection unit. Results We utilized GATE simulations of a human forearm phantom with a blood flow model, as well as a model for dynamic radioactive bolus activity concentration based on clinical measurements. A fixed configuration of 14 and, also separately, 8 detectors were employed around the phantom, and simulations were performed to investigate signal detection parameters. Bismuth germanate (BGO) crystals proved to show the highest count rate capability and sensitivity to a simulated BTAC with a maximum coincidence rate of 575 cps. Repeatable location of the blood vessels in the forearm allowed a half-ring design with only 8 detectors. Using this configuration, maximum coincident rates of 250 cps and 42 cps were achieved with simulation of activity concentration determined from 15O and 18F arterial blood sampling. NECR simulated in a water phantom at 3 different vertical positions inside the 8-detector system (Y = − 1 cm, Y = − 2 cm, and Y = −3 cm) was 8360 cps, 13,041 cps, and 20,476 cps at an activity of 3.5 MBq. Addition of extra axial detection rings to the half-ring configuration provided increases in system sensitivity by a factor of approximately 10. Conclusions Initial simulations demonstrated that the configuration of a single half-ring 8 detector of monolithic BGO crystals could describe the simulated BTAC in a clinically relevant forearm phantom with good signal properties, and an increased number of axial detection rings can provide increased sensitivity of the system. The system would find use in the derivation of the BTAC for use in the application of kinetic models without physical arterial sampling or reliance on image-based techniques.
Collapse
Affiliation(s)
- Yassine Toufique
- Advanced Scientific Computing Center, Texas A&M University at Qatar, Doha, Qatar
| | - Othmane Bouhali
- Advanced Scientific Computing Center, Texas A&M University at Qatar, Doha, Qatar.,Qatar Computing Research Institute, Hamad Bin Khalifa University, Doha, Qatar
| | - Pauline Negre
- Clinical Imaging Research Centre, Centre for Translational Medicine, National University of Singapore, Singapore, Singapore
| | - Jim O' Doherty
- Clinical Imaging Research Centre, Centre for Translational Medicine, National University of Singapore, Singapore, Singapore.
| |
Collapse
|
6
|
Kang Y, Mozley PD, Verma A, Schlyer D, Henchcliffe C, Gauthier SA, Chiao PC, He B, Nikolopoulou A, Logan J, Sullivan JM, Pryor KO, Hesterman J, Kothari PJ, Vallabhajosula S. Noninvasive PK11195-PET Image Analysis Techniques Can Detect Abnormal Cerebral Microglial Activation in Parkinson's Disease. J Neuroimaging 2018; 28:496-505. [PMID: 29727504 PMCID: PMC6174975 DOI: 10.1111/jon.12519] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Accepted: 04/15/2018] [Indexed: 11/27/2022] Open
Abstract
BACKGROUND AND PURPOSE Neuroinflammation has been implicated in the pathophysiology of Parkinson's disease (PD), which might be influenced by successful neuroprotective drugs. The uptake of [11 C](R)-PK11195 (PK) is often considered to be a proxy for neuroinflammation, and can be quantified using the Logan graphical method with an image-derived blood input function, or the Logan reference tissue model using automated reference region extraction. The purposes of this study were (1) to assess whether these noninvasive image analysis methods can discriminate between patients with PD and healthy volunteers (HVs), and (2) to establish the effect size that would be required to distinguish true drug-induced changes from system variance in longitudinal trials. METHODS The sample consisted of 20 participants with PD and 19 HVs. Two independent teams analyzed the data to compare the volume of distribution calculated using image-derived input functions (IDIFs), and binding potentials calculated using the Logan reference region model. RESULTS With all methods, the higher signal-to-background in patients resulted in lower variability and better repeatability than in controls. We were able to use noninvasive techniques showing significantly increased uptake of PK in multiple brain regions of participants with PD compared to HVs. CONCLUSION Although not necessarily reflecting absolute values, these noninvasive image analysis methods can discriminate between PD patients and HVs. We see a difference of 24% in the substantia nigra between PD and HV with a repeatability coefficient of 13%, showing that it will be possible to estimate responses in longitudinal, within subject trials of novel neuroprotective drugs.
Collapse
Affiliation(s)
| | | | | | - David Schlyer
- Weill Cornell MedicineNew YorkNY
- Brookhaven National LaboratoriesNY
| | | | | | | | - Bin He
- Weill Cornell MedicineNew YorkNY
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Kudomi N, Maeda Y, Yamamoto H, Yamamoto Y, Hatakeyama T, Nishiyama Y. Reconstruction of input functions from a dynamic PET image with sequential administration of 15O 2 and [Formula: see text] for noninvasive and ultra-rapid measurement of CBF, OEF, and CMRO 2. J Cereb Blood Flow Metab 2018; 38:780-792. [PMID: 28595496 PMCID: PMC5987943 DOI: 10.1177/0271678x17713574] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/02/2017] [Revised: 04/19/2017] [Accepted: 05/15/2017] [Indexed: 11/16/2022]
Abstract
CBF, OEF, and CMRO2 images can be quantitatively assessed using PET. Their image calculation requires arterial input functions, which require invasive procedure. The aim of the present study was to develop a non-invasive approach with image-derived input functions (IDIFs) using an image from an ultra-rapid O2 and C15O2 protocol. Our technique consists of using a formula to express the input using tissue curve with rate constants. For multiple tissue curves, the rate constants were estimated so as to minimize the differences of the inputs using the multiple tissue curves. The estimated rates were used to express the inputs and the mean of the estimated inputs was used as an IDIF. The method was tested in human subjects ( n = 24). The estimated IDIFs were well-reproduced against the measured ones. The difference in the calculated CBF, OEF, and CMRO2 values by the two methods was small (<10%) against the invasive method, and the values showed tight correlations ( r = 0.97). The simulation showed errors associated with the assumed parameters were less than ∼10%. Our results demonstrate that IDIFs can be reconstructed from tissue curves, suggesting the possibility of using a non-invasive technique to assess CBF, OEF, and CMRO2.
Collapse
Affiliation(s)
- Nobuyuki Kudomi
- Department of Medical Physics, Kagawa University, Kagawa, Japan
| | - Yukito Maeda
- Department of Radiology, Kagawa University Hospital, Kagawa, Japan
| | | | - Yuka Yamamoto
- Department of Radiology, Kagawa University, Kagawa, Japan
| | | | | |
Collapse
|
8
|
Espagnet R, Frezza A, Martin JP, Hamel LA, Lechippey L, Beauregard JM, Després P. A CZT-based blood counter for quantitative molecular imaging. EJNMMI Phys 2017; 4:18. [PMID: 28577291 PMCID: PMC5457380 DOI: 10.1186/s40658-017-0184-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2016] [Accepted: 05/02/2017] [Indexed: 11/30/2022] Open
Abstract
Background Robust quantitative analysis in positron emission tomography (PET) and in single-photon emission computed tomography (SPECT) typically requires the time-activity curve as an input function for the pharmacokinetic modeling of tracer uptake. For this purpose, a new automated tool for the determination of blood activity as a function of time is presented. The device, compact enough to be used on the patient bed, relies on a peristaltic pump for continuous blood withdrawal at user-defined rates. Gamma detection is based on a 20 × 20 × 15 mm3 cadmium zinc telluride (CZT) detector, read by custom-made electronics and a field-programmable gate array-based signal processing unit. A graphical user interface (GUI) allows users to select parameters and easily perform acquisitions. Results This paper presents the overall design of the device as well as the results related to the detector performance in terms of stability, sensitivity and energy resolution. Results from a patient study are also reported. The device achieved a sensitivity of 7.1 cps/(kBq/mL) and a minimum detectable activity of 2.5 kBq/ml for 18F. The gamma counter also demonstrated an excellent stability with a deviation in count rates inferior to 0.05% over 6 h. An energy resolution of 8% was achieved at 662 keV. Conclusions The patient study was conclusive and demonstrated that the compact gamma blood counter developed has the sensitivity and the stability required to conduct quantitative molecular imaging studies in PET and SPECT.
Collapse
Affiliation(s)
- Romain Espagnet
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, G1V 0A6, QC, Canada
| | - Andrea Frezza
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, G1V 0A6, QC, Canada
| | - Jean-Pierre Martin
- Department of Physics, Université de Montréal, C.P. 6128, Montréal, H3C 3J7, QC, Canada
| | - Louis-André Hamel
- Department of Physics, Université de Montréal, C.P. 6128, Montréal, H3C 3J7, QC, Canada
| | - Laëtitia Lechippey
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, G1V 0A6, QC, Canada
| | - Jean-Mathieu Beauregard
- Department of Medical Imaging and Research Center of CHU de Québec - Université Laval, Quebec City, G1R 2J6, QC, Canada.,Department of Radiology and Nuclear medicine and Cancer Research Center, Université Laval, Quebec CityQC, G1V 0A6, Canada
| | - Philippe Després
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, G1V 0A6, QC, Canada. .,Department of Radiation Oncology and Research Center of CHU de Québec - Université Laval, Quebec City, G1R 2J6, QC, Canada.
| |
Collapse
|
9
|
Kudomi N, Maeda Y, Yamamoto Y, Nishiyama Y. Reconstruction of an input function from a dynamic PET water image using multiple tissue curves. Phys Med Biol 2016; 61:5755-67. [DOI: 10.1088/0031-9155/61/15/5755] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
10
|
Fung EK, Carson RE. Cerebral blood flow with [15O]water PET studies using an image-derived input function and MR-defined carotid centerlines. Phys Med Biol 2013; 58:1903-23. [PMID: 23442733 DOI: 10.1088/0031-9155/58/6/1903] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Full quantitative analysis of brain PET data requires knowledge of the arterial input function into the brain. Such data are normally acquired by arterial sampling with corrections for delay and dispersion to account for the distant sampling site. Several attempts have been made to extract an image-derived input function (IDIF) directly from the internal carotid arteries that supply the brain and are often visible in brain PET images. We have devised a method of delineating the internal carotids in co-registered magnetic resonance (MR) images using the level-set method and applying the segmentations to PET images using a novel centerline approach. Centerlines of the segmented carotids were modeled as cubic splines and re-registered in PET images summed over the early portion of the scan. Using information from the anatomical center of the vessel should minimize partial volume and spillover effects. Centerline time-activity curves were taken as the mean of the values for points along the centerline interpolated from neighboring voxels. A scale factor correction was derived from calculation of cerebral blood flow (CBF) using gold standard arterial blood measurements. We have applied the method to human subject data from multiple injections of [(15)O]water on the HRRT. The method was assessed by calculating the area under the curve (AUC) of the IDIF and the CBF, and comparing these to values computed using the gold standard arterial input curve. The average ratio of IDIF to arterial AUC (apparent recovery coefficient: aRC) across 9 subjects with multiple (n = 69) injections was 0.49 ± 0.09 at 0-30 s post tracer arrival, 0.45 ± 0.09 at 30-60 s, and 0.46 ± 0.09 at 60-90 s. Gray and white matter CBF values were 61.4 ± 11.0 and 15.6 ± 3.0 mL/min/100 g tissue using sampled blood data. Using IDIF centerlines scaled by the average aRC over each subjects' injections, gray and white matter CBF values were 61.3 ± 13.5 and 15.5 ± 3.4 mL/min/100 g tissue. Using global average aRC values, the means were unchanged, and intersubject variability was noticeably reduced. This MR-based centerline method with local re-registration to [(15)O]water PET yields a consistent IDIF over multiple injections in the same subject, thus permitting the absolute quantification of CBF without arterial input function measurements.
Collapse
Affiliation(s)
- Edward K Fung
- Department of Biomedical Engineering, Yale University, 801 Howard Avenue, New Haven, CT 06520, USA.
| | | |
Collapse
|
11
|
Zanotti-Fregonara P, Hines CS, Zoghbi SS, Liow JS, Zhang Y, Pike VW, Drevets WC, Mallinger AG, Zarate CA, Fujita M, Innis RB. Population-based input function and image-derived input function for [¹¹C](R)-rolipram PET imaging: methodology, validation and application to the study of major depressive disorder. Neuroimage 2012; 63:1532-41. [PMID: 22906792 PMCID: PMC3472081 DOI: 10.1016/j.neuroimage.2012.08.007] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 07/31/2012] [Accepted: 08/05/2012] [Indexed: 01/21/2023] Open
Abstract
UNLABELLED Quantitative PET studies of neuroreceptor tracers typically require that arterial input function be measured. The aim of this study was to explore the use of a population-based input function (PBIF) and an image-derived input function (IDIF) for [(11)C](R)-rolipram kinetic analysis, with the goal of reducing - and possibly eliminating - the number of arterial blood samples needed to measure parent radioligand concentrations. METHODS A PBIF was first generated using [(11)C](R)-rolipram parent time-activity curves from 12 healthy volunteers (Group 1). Both invasive (blood samples) and non-invasive (body weight, body surface area, and lean body mass) scaling methods for PBIF were tested. The scaling method that gave the best estimate of the Logan-V(T) values was then used to determine the test-retest variability of PBIF in Group 1 and then prospectively applied to another population of 25 healthy subjects (Group 2), as well as to a population of 26 patients with major depressive disorder (Group 3). Results were also compared to those obtained with an image-derived input function (IDIF) from the internal carotid artery. In some subjects, we measured arteriovenous differences in [(11)C](R)-rolipram concentration to see whether venous samples could be used instead of arterial samples. Finally, we assessed the ability of IDIF and PBIF to discriminate depressed patients (MDD) and healthy subjects. RESULTS Arterial blood-scaled PBIF gave better results than any non-invasive scaling technique. Excellent results were obtained when the blood-scaled PBIF was prospectively applied to the subjects in Group 2 (V(T) ratio 1.02±0.05; mean±SD) and Group 3 (V(T) ratio 1.03±0.04). Equally accurate results were obtained for two subpopulations of subjects drawn from Groups 2 and 3 who had very differently shaped (i.e. "flatter" or "steeper") input functions compared to PBIF (V(T) ratio 1.07±0.04 and 0.99±0.04, respectively). Results obtained via PBIF were equivalent to those obtained via IDIF (V(T) ratio 0.99±0.05 and 1.00±0.04 for healthy subjects and MDD patients, respectively). Retest variability of PBIF was equivalent to that obtained with full input function and IDIF (14.5%, 15.2%, and 14.1%, respectively). Due to [(11)C](R)-rolipram arteriovenous differences, venous samples could not be substituted for arterial samples. With both IDIF and PBIF, depressed patients had a 20% reduction in [(11)C](R)-rolipram binding as compared to control (two-way ANOVA: p=0.008 and 0.005, respectively). These results were almost equivalent to those obtained using 23 arterial samples. CONCLUSION Although some arterial samples are still necessary, both PBIF and IDIF are accurate and precise alternatives to full arterial input function for [(11)C](R)-rolipram PET studies. Both techniques give accurate results with low variability, even for clinically different groups of subjects and those with very differently shaped input functions.
Collapse
Affiliation(s)
- Paolo Zanotti-Fregonara
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Christina S. Hines
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Sami S. Zoghbi
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Jeih-San Liow
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Yi Zhang
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Victor W. Pike
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Wayne C. Drevets
- Department of Psychiatry, Oklahoma University School of Community Medicine, Oklahoma University Health Sciences Center. Tulsa. Oklahoma
| | - Alan G. Mallinger
- Experimental Therapeutics & Pathophysiology Branch, Intramural Research Program, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Carlos A. Zarate
- Experimental Therapeutics & Pathophysiology Branch, Intramural Research Program, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Masahiro Fujita
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| | - Robert B. Innis
- Molecular Imaging Branch, National Institute of Mental Health, National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
12
|
Minimally invasive input function for 2-18F-fluoro-A-85380 brain PET studies. Eur J Nucl Med Mol Imaging 2012; 39:651-9. [PMID: 22231015 DOI: 10.1007/s00259-011-2004-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2011] [Accepted: 11/08/2011] [Indexed: 10/14/2022]
Abstract
PURPOSE Quantitative neuroreceptor positron emission tomography (PET) studies often require arterial cannulation to measure input function. While population-based input function (PBIF) would be a less invasive alternative, it has only rarely been used in conjunction with neuroreceptor PET tracers. The aims of this study were (1) to validate the use of PBIF for 2-(18)F-fluoro-A-85380, a tracer for nicotinic receptors; (2) to compare the accuracy of measures obtained via PBIF to those obtained via blood-scaled image-derived input function (IDIF) from carotid arteries; and (3) to explore the possibility of using venous instead of arterial samples for both PBIF and IDIF. METHODS Ten healthy volunteers underwent a dynamic 2-(18)F-fluoro-A-85380 brain PET scan with arterial and, in seven subjects, concurrent venous serial blood sampling. PBIF was obtained by averaging the normalized metabolite-corrected arterial input function and subsequently scaling each curve with individual blood samples. IDIF was obtained from the carotid arteries using a blood-scaling method. Estimated Logan distribution volume (V(T)) values were compared to the reference values obtained from arterial cannulation. RESULTS For all subjects, PBIF curves scaled with arterial samples were similar in shape and magnitude to the reference arterial input function. The Logan V(T) ratio was 1.00 ± 0.05; all subjects had an estimation error <10%. IDIF gave slightly less accurate results (V(T) ratio 1.03 ± 0.07; eight of ten subjects had an error <10%). PBIF scaled with venous samples yielded inaccurate results (V(T) ratio 1.13 ± 0.13; only three of seven subjects had an error <10%). Due to arteriovenous differences at early time points, IDIF could not be calculated using venous samples. CONCLUSION PBIF scaled with arterial samples accurately estimates Logan V(T) for 2-(18)F-fluoro-A-85380. Results obtained with PBIF were slightly better than those obtained with IDIF. Due to arteriovenous concentration differences, venous samples cannot be substituted for arterial samples.
Collapse
|
13
|
Zanotti-Fregonara P, Chen K, Liow JS, Fujita M, Innis RB. Image-derived input function for brain PET studies: many challenges and few opportunities. J Cereb Blood Flow Metab 2011; 31:1986-98. [PMID: 21811289 PMCID: PMC3208145 DOI: 10.1038/jcbfm.2011.107] [Citation(s) in RCA: 154] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Quantitative positron emission tomography (PET) brain studies often require that the input function be measured, typically via arterial cannulation. Image-derived input function (IDIF) is an elegant and attractive noninvasive alternative to arterial sampling. However, IDIF is also a very challenging technique associated with several problems that must be overcome before it can be successfully implemented in clinical practice. As a result, IDIF is rarely used as a tool to reduce invasiveness in patients. The aim of the present review was to identify the methodological problems that hinder widespread use of IDIF in PET brain studies. We conclude that IDIF can be successfully implemented only with a minority of PET tracers. Even in those cases, it only rarely translates into a less-invasive procedure for the patient. Finally, we discuss some possible alternative methods for obtaining less-invasive input function.
Collapse
|
14
|
Zanotti-Fregonara P, Liow JS, Fujita M, Dusch E, Zoghbi SS, Luong E, Boellaard R, Pike VW, Comtat C, Innis RB. Image-derived input function for human brain using high resolution PET imaging with [C](R)-rolipram and [C]PBR28. PLoS One 2011; 6:e17056. [PMID: 21364880 PMCID: PMC3045425 DOI: 10.1371/journal.pone.0017056] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2010] [Accepted: 01/13/2011] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND The aim of this study was to test seven previously published image-input methods in state-of-the-art high resolution PET brain images. Images were obtained with a High Resolution Research Tomograph plus a resolution-recovery reconstruction algorithm using two different radioligands with different radiometabolite fractions. Three of the methods required arterial blood samples to scale the image-input, and four were blood-free methods. METHODS All seven methods were tested on twelve scans with [(11)C](R)-rolipram, which has a low radiometabolite fraction, and on nineteen scans with [(11)C]PBR28 (high radiometabolite fraction). Logan V(T) values for both blood and image inputs were calculated using the metabolite-corrected input functions. The agreement of image-derived Logan V(T) values with the reference blood-derived Logan V(T) values was quantified using a scoring system. Using the image input methods that gave the most accurate results with Logan analysis, we also performed kinetic modelling with a two-tissue compartment model. RESULTS For both radioligands the highest scores were obtained with two blood-based methods, while the blood-free methods generally performed poorly. All methods gave higher scores with [(11)C](R)-rolipram, which has a lower metabolite fraction. Compartment modeling gave less reliable results, especially for the estimation of individual rate constants. CONCLUSION OUR STUDY SHOWS THAT: 1) Image input methods that are validated for a specific tracer and a specific machine may not perform equally well in a different setting; 2) despite the use of high resolution PET images, blood samples are still necessary to obtain a reliable image input function; 3) the accuracy of image input may also vary between radioligands depending on the magnitude of the radiometabolite fraction: the higher the metabolite fraction of a given tracer (e.g., [(11)C]PBR28), the more difficult it is to obtain a reliable image-derived input function; and 4) in association with image inputs, graphical analyses should be preferred over compartmental modelling.
Collapse
Affiliation(s)
- Paolo Zanotti-Fregonara
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
- * E-mail:
| | - Jeih-San Liow
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| | - Masahiro Fujita
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| | | | - Sami S. Zoghbi
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| | - Elise Luong
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| | - Ronald Boellaard
- Department of Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands
| | - Victor W. Pike
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| | | | - Robert B. Innis
- Molecular Imaging Branch, National Institute of Mental Health (NIMH), National Institutes of Health (NIH), Bethesda, Maryland, United States of America
| |
Collapse
|