1
|
Alves VDPV, Ata NA, MacLean J, Sharp SE, Li Y, Brady S, Trout AT. Reduced count pediatric whole-body 18F-FDG PET imaging reconstruction with a Bayesian penalized likelihood algorithm. Pediatr Radiol 2024; 54:170-180. [PMID: 37962603 DOI: 10.1007/s00247-023-05801-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 10/24/2023] [Accepted: 10/26/2023] [Indexed: 11/15/2023]
Abstract
BACKGROUND Advanced positron emission tomography (PET) image reconstruction methods promise to allow optimized PET/CT protocols with improved image quality, decreased administered activity and/or acquisition times. OBJECTIVE To evaluate the impact of reducing counts (simulating reduced acquisition time) in block sequential regularized expectation maximization (BSREM) reconstructed pediatric whole-body 18F-fluorodeoxyglucose (FDG) PET images, and to compare BSERM with ordered-subset expectation maximization (OSEM) reconstructed reduced-count images. MATERIALS AND METHODS Twenty children (16 male) underwent clinical whole-body 18F-FDG PET/CT examinations using a 25-cm axial field-of-view (FOV) digital PET/CT system at 90 s per bed (s/bed) with BSREM reconstruction (β=700). Reduced count simulations with varied BSREM β levels were generated from list-mode data: 60 s/bed, β=800; 50 s/bed, β=900; 40 s/bed, β=1000; and 30 s/bed, β=1300. In addition, a single OSEM reconstruction was created at 60 s/bed based on prior literature. Qualitative (Likert scores) and quantitative (standardized uptake value [SUV]) analyses were performed to evaluate image quality and quantitation across simulated reconstructions. RESULTS The mean patient age was 9.0 ± 5.5 (SD) years, mean weight was 38.5 ± 24.5 kg, and mean administered 18F-FDG activity was 4.5 ± 0.7 (SD) MBq/kg. Between BSREM reconstructions, no qualitative measure showed a significant difference versus the 90 s/bed β=700 standard (all P>0.05). SUVmax values for lesions were significantly lower from 90 s/bed, β=700 only at a simulated acquisition time of 30 s/bed, β=1300 (P=0.001). In a side-by-side comparison of BSREM versus OSEM reconstructions, 40 s/bed, β=1000 images were generally preferred over 60 s/bed TOF OSEM images. CONCLUSION In children who undergo whole-body 18F-FDG PET/CT on a 25-cm FOV digital PET/CT scanner, reductions in acquisition time or, by corollary, administered radiopharmaceutical activity of >50% from a clinical standard of 90 s/bed may be possible while maintaining diagnostic quality when a BSREM reconstruction algorithm is used.
Collapse
Affiliation(s)
- Vinicius de Padua V Alves
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Nadeen Abu Ata
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Joseph MacLean
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
| | - Susan E Sharp
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Yinan Li
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Samuel Brady
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Ave, Kasota Building MLC 5031, Cincinnati, OH, 45226, USA.
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
| |
Collapse
|
2
|
Simulated Reduced-Count Whole-Body FDG PET: Evaluation in Children and Young Adults Imaged on a Digital PET Scanner. AJR Am J Roentgenol 2022; 219:952-961. [PMID: 35731102 DOI: 10.2214/ajr.22.27894] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND. Digital PET scanners with increased sensitivity may allow shorter scan acquisition times or reductions in administered radiopharmaceutical activities. OBJECTIVE. The purpose of this study was to evaluate in children and young adults the impact of shorter simulated acquisition times on the quality of whole-body FDG PET images obtained using a digital PET/CT system. METHODS. This retrospective study included 27 children and young adults (nine male and 18 female patients) who underwent clinically indicated whole-body FDG PET/CT examinations performed using a 25-cm axial FOV PET/CT system at 90 s per bed position (expressed hereafter as seconds per bed). Raw list-mode data were reprocessed to simulate acquisition times of 60, 55, 50, 45, 40, and 30 s/bed. Three radiologists independently reviewed reconstructed images and assigned Likert scores for lesion conspicuity, normal structure conspicuity, image quality, and image noise. A separate observer recorded the SUVmax, SUVmean, and SD of the SUV (SUVSD) for liver, thigh, and the most FDG-avid lesion. The SUVSD/SUVmean (the SUVSD divided by the SUVmean) was calculated as a surrogate of image noise. ANOVA, the Friedman test, and the Dunn test were used to compare qualitative measures (combining reader scores) and SUV measurements. RESULTS. The mean patient age was 10.8 ± 8.3 (SD) years, mean BMI was 18.7 ± 2.9, and mean administered FDG activity was 4.44 ± 0.37 MBq/kg (0.12 ± 0.01 mCi/kg). No qualitative measure showed a significant difference versus 90 s/bed for the simulated acquisition at 60 s/bed (all p > .05). Significant differences (all p < .05) versus 90 s/bed were observed for lesion conspicuity at at most 40 s/bed, conspicuity of normal structures and overall image quality at at most 45 s/bed, and image noise at at most 55 s/bed. SUVmean was not significantly different from 90 s/bed for any site for any reduced-count simulation (all p > .05). SUVSD/SUVmean and SUVmax showed gradual increases with decreasing acquisition times and were significantly different from 90 s/bed only for liver at 60 s/bed (for SUVmax: 1.00 ± 0.00 vs 1.05 ± 0.03, p = .02; for SUVSD/SUVmean: 0.09 ± 0.02 vs 0.11 ± 0.02, p = .04). CONCLUSION. Favorable findings for the simulated acquisition at 60 s/bed suggest that, in children and young adults who undergo imaging performed using a 25-cm FOV digital PET scanner, acquisition time or administered FDG activity may be decreased by approximately 33% from the clinical standard without significantly impacting image quality. CLINICAL IMPACT. A 25-cm axial FOV digital scanner may allow FDG PET/CT examinations to be performed with reduced radiation exposure or faster scan acquisition times.
Collapse
|
3
|
Usmani S, Ahmed N, Gnanasegaran G, Musbah A, Al Kandari F, Van den Wyngaert T. 18F-NaF PET/CT of Obese Patients on a Lutetium-Yttrium Oxyorthosilicate PET/CT System: Patient Dosimetry, Optimization of Injected Activity, and Acquisition Time. J Nucl Med Technol 2021; 49:150-155. [PMID: 33380519 DOI: 10.2967/jnmt.120.258137] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Accepted: 12/28/2020] [Indexed: 11/16/2022] Open
Abstract
18F-NaF PET/CT has a rapid single-pass extraction and fast clearance from soft tissues, resulting in a good target-to-background ratio. This study aimed to establish the optimum acquisition time and dosimetry for 18F-NaF PET/CT to evaluate bone metastases in obese patients. A secondary objective was to evaluate the impact of acquisition time on image quality, lesion detection rate, noise level, and radiation burden in this patient group. Methods: In total, 60 patients were included in the study (20 patients with a body mass index (BMI) of 30.0-34.9 kg/m2, 20 with a BMI of 35-39.9 kg/m2, and 20 with a BMI of >40 kg/m2). Images were acquired after intravenous injection of a 2.2 MBq/kg (0.06 mCi/kg) dose of 18F-NaF. Data were acquired in list mode using ordered-subset expectation maximization reconstruction. The raw data were rebinned to simulate scans with acquisition times of 2, 2.5, and 3 min per bed position. The scans were visually analyzed by 2 observers and scored by rank against a panel of parameters (overall image quality, noise level, background soft tissue, and lesion detectability), and the contrast-to-noise ratio (CNR) was calculated. Results: The mean CNR was 20.19 ± 8.39 for a 2-min acquisition, 21.03 ± 8.35 for 2.5 min, and 22.16 ± 8.37 for 3 min. There were no statistically significant differences in CNR among the 3 different acquisition durations (P > 0.05). Lesion delineation was excellent and independent of the acquisition time. All relevant lesions could be identified with all 3 acquisition times. A mean activity of 215.4 ± 31.3 MBq was injected, with estimated mean effective absorbed doses of 4.09 ± 0.59 mSv for 18F-NaF PET and 7.88 ± 1.66 mSv for CT alone. Conclusion: 18F-NaF PET/CT can be beneficial in obese patients because of its good pharmacokinetics. Optimal osseous staging can be achieved with relatively low doses and radiation burden. Lesion delineation was excellent regardless of acquisition time. However, it is recommended that an acquisition of 3 min per bed position be used in patients with a BMI of more than 40.
Collapse
Affiliation(s)
- Sharjeel Usmani
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Khaitan, Kuwait;
| | - Najeeb Ahmed
- Jack Brignall PET/CT Centre, Castle Hill Hospital, Cottingham, United Kingdom
| | | | - Ahmed Musbah
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Khaitan, Kuwait
| | - Fareeda Al Kandari
- Department of Nuclear Medicine, Kuwait Cancer Control Centre, Khaitan, Kuwait
| | | |
Collapse
|
4
|
[ 18F]FDG uptake of the normal spinal cord in PET/MR imaging: comparison with PET/CT imaging. EJNMMI Res 2020; 10:91. [PMID: 32761394 PMCID: PMC7410944 DOI: 10.1186/s13550-020-00680-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 07/28/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The lack of visualization of the spinal cord hinders the evaluation of [18F]Fluoro-deoxy-glucose (FDG) uptake of the spinal cord in PET/CT. By exploiting the capability of MRI to precisely outline the spinal cord, we performed a retrospective study aimed to define normal pattern of spinal cord [18F]FDG uptake in PET/MRI. METHODS Forty-one patients with lymphoma without clinical or MRI signs of spinal cord or bone marrow involvement underwent simultaneous PET and MRI acquisition using Siemens Biograph mMR after injection of 3.5 MBq/kg body weight of [18F]FDG for staging purposes. Using a custom-made software, we placed ROIs of 3 and 9 mm in diameter in the spinal cord, lumbar CSF, and vertebral marrow that were identified on MRI at 5 levels (C2, C5, T6, T12, and L3). The SUVmax, SUVmean, and the SUVmax and SUVmean normalized (NSUVmax and NSUVmean) to the liver were measured. For comparison, the same ROIs were placed in PET-CT images obtained immediately before the PET-MRI acquisition following the same tracer injection. RESULTS On PET/MRI using the 3 mm ROI, the following average (all level excluding L3) spinal cord median (1st and 3rd quartile) values were measured: SUVmean, 1.68 (1.39 and 1.83); SUVmax, 1.92 (1.60 and 2.14); NSUVmean, 1.18 (0.93 and 1.36); and NSUVmax, 1.27 (1.01 and 1.33). Using the 9 mm ROI, the corresponding values were SUVmean, 1.41 (1.25-1.55); SUVmax, 2.41 (2.08 and 2.61); NSUVmean, 0.93 (0.79 and 1.04); and NSUVmax, 1.28 (1.02 and 1.39). Using the 3 mm ROI, the highest values of PET-MRI SUVmax, SUVmean, NSUVmax, and NSUVmean were consistently observed at C5 and the lowest at T6. Using a 9 mm ROI, the highest values were consistently observed at C5 and the lowest at T12 or T6. The spinal cord [18F]FDG-uptake values correlated with the bone marrow uptake at the same level, especially in case of NSUVmax. Comparison with PET-CT data revealed that the average SUVmax and SUVmean of the spinal cord were similar in PET-MRI and PET-CT. However, the average NSUVmax and NSUVmean of the spinal cord were higher (range 21-47%) in PET-MRI than in PET-CT. CONCLUSIONS Using a whole-body protocol, we defined the maximum and mean [18F]FDG uptake of the normal spinal cord in PET/MRI. While the observed values show the expected longitudinal distribution, they appear to be higher than those measured in PET/CT. Normalization of the SUVmax and SUVmean of the spinal cord to the liver radiotracer uptake could help in multi-institutional comparisons and studies.
Collapse
|
5
|
Zucchetta P, Branchini M, Zorz A, Bodanza V, Cecchin D, Paiusco M, Bui F. Quantitative analysis of image metrics for reduced and standard dose pediatric 18F-FDG PET/MRI examinations. Br J Radiol 2019; 92:20180438. [PMID: 30673306 DOI: 10.1259/bjr.20180438] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
OBJECTIVE: The study performs a comprehensive analysis of image metrics to objectively support the reduction of injected activity in pediatric oncology 18F-FDG PET/MR (18F-fludeoxyglucose PET/MR) examinations. Contrast-to-Noise Ratio (CNR), Normalized Noise (NN), tumor burden, and standardized uptake value (SUV) parameters stability were investigated to robustly define the acceptable reduced activity level that preserves the clinical utility of images, considering different PET applications. METHODS: 21 PET/MRI examinations performed on a 3-Tesla Biograph mMR scanner were analyzed. Tracer activity reduction was stimulated by decreasing the count statistics of the original list-mode data (3 MBq kg-1). In addition to the already studied SUV metrics and subjective scoring on lesion detectability, a thorough analysis of CNR, NN, Metabolic Tumor Volume (MTV), and Total Lesion Glycolysis (TLG) was performed. RESULTS: SUVmax and SUVmean increased more than 5% only in 0.6 MBq kg-1 reconstructed images (+10% and +9%, respectively), while SUVpeak was almost unaffected (average variations < 2%). The quantified CNR, NN, MTV, and TLG behavior with the decrease of the injected activity clearly defines 1.5 MBq kg-1 as a threshold of activity after which the quality of the image degrades. Subjective and objective analyses yielded consistent results. All 56 lesions were detected until activity of 1.2 MBq kg-1, whereas five lesions were missed on the 0.6 MBq kg-1 image. Perceived image quality (IQ) decreased in Lower Tracer Activity (LTA) images but remained acceptable until 1.5 MBq kg-1. CONCLUSION: Results about the stability of image metrics beyond the semi-quantitative SUV parameters and subjective analysis, rigorously proves the feasibility of the reduction of injected activity to 1.5 MBqkg-1 for pediatric patients aged between 7 and 17 years. ADVANCES IN KNOWLEDGE: This is the first report on the quantitative evaluation of the effect of activity reduction on image quality in pediatric PET/MR. The findings offer objective corroboration to the feasibility of a significant dose reduction without consequences on clinical image reading and tumor burden metrics.
Collapse
Affiliation(s)
- Pietro Zucchetta
- 1 Nuclear Medicine Unit, Department of Medicine DIMED, University-Hospital of Padova , Padova , Italy
| | - Marco Branchini
- 2 Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS , Padova , Italy
| | - Alessandra Zorz
- 2 Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS , Padova , Italy
| | - Valentina Bodanza
- 1 Nuclear Medicine Unit, Department of Medicine DIMED, University-Hospital of Padova , Padova , Italy
| | - Diego Cecchin
- 1 Nuclear Medicine Unit, Department of Medicine DIMED, University-Hospital of Padova , Padova , Italy
| | - Marta Paiusco
- 2 Medical Physics Department, Veneto Institute of Oncology IOV-IRCCS , Padova , Italy
| | - Franco Bui
- 1 Nuclear Medicine Unit, Department of Medicine DIMED, University-Hospital of Padova , Padova , Italy
| |
Collapse
|
6
|
Wickham F, McMeekin H, Burniston M, McCool D, Pencharz D, Skillen A, Wagner T. Patient-specific optimisation of administered activity and acquisition times for 18F-FDG PET imaging. EJNMMI Res 2017; 7:3. [PMID: 28091978 PMCID: PMC5236047 DOI: 10.1186/s13550-016-0250-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 12/16/2016] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND The purpose of this study is to identify a method for optimising the administered activity and acquisition time for 18F-FDG PET imaging, yielding images of consistent quality for patients with varying body sizes and compositions, while limiting radiation doses to patients and staff. Patients referred for FDG scans had bioimpedance measurements. They were injected with 3 MBq/kg of 18F up to 370 MBq and scanned on a Siemens Biograph mCT at 3 or 4 min per bed position. Data were rebinned to simulate 2- and 1-min acquisitions. Subjective assessments of image quality made by an experienced physician were compared with objective measurements based on signal-to-noise ratio and noise equivalent counts (NEC). A target objective measure of image quality was identified. The activity and acquisition time required to achieve this were calculated for each subject. Multiple regression analysis was used to identify expressions for the activity and acquisition time required in terms of easily measurable patient characteristics. RESULTS One hundred and eleven patients were recruited, and subjective and objective assessments of image quality were compared for 321 full and reduced time scans. NEC-per-metre was identified as the objective measure which best correlated with the subjective assessment (Spearman rank correlation coefficient 0.77) and the best discriminator for images with a subjective assessment of "definitely adequate" (area under the ROC curve 0.94). A target of 37 Mcount/m was identified. Expressions were identified in terms of patient sex, height and weight for the activity and acquisition time required to achieve this target. Including measurements of body composition in these expressions was not useful. Using these expressions would reduce the mean activity administered to this patient group by 66 MBq compared to the current protocol. CONCLUSIONS Expressions have been identified for the activity and acquisition times required to achieve consistent image quality in FDG imaging with reduced patient and staff doses. These expressions might need to be adapted for other systems and reconstruction protocols.
Collapse
Affiliation(s)
- Fred Wickham
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK.
| | - Helena McMeekin
- Hermes Medical Solutions, 22 Long Acre, London, WC2E 9LY, UK
| | - Maria Burniston
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| | - Daniel McCool
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| | - Deborah Pencharz
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| | - Annah Skillen
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| | - Thomas Wagner
- Nuclear Medicine Department, Royal Free London NHS Foundation Trust, Pond Street, London, NW3 2QG, UK
| |
Collapse
|
7
|
Quantification accuracy of neuro-oncology PET data as a function of emission scan duration in PET/MR compared to PET/CT. Eur J Radiol 2017; 95:257-264. [PMID: 28987677 DOI: 10.1016/j.ejrad.2017.08.024] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 08/23/2017] [Indexed: 11/27/2022]
Abstract
OBJECTIVES To evaluate and compare the effect of reduced acquisition time, as a surrogate of injected activity, on the PET quantification accuracy in PET/CT and PET/MR imaging. METHODS Twenty min 18F-FDG phantom measurements and 10min 18F-FET brain scans were acquired in a Biograph-True-Point-True-View PET/CT (n=8) and a Biograph mMR PET/MR (n=16). Listmode data were repeatedly split into frames of 1min to 10min length and reconstructed using two different reconstruction settings of a 3D-OSEM algorithm: with post-filtering ("OSEM"), and without post-filtering but with resolution recovery ("PSF"). Recovery coefficients (RCmax, RCA50) and standard uptake values (SUVmax, SUVA50) were evaluated. RESULTS RCmax (phantom) and SUVmax (patients) increased significantly when reducing the frame duration. Significantly lower deviations were observed for RCA50 and SUVA50, respectively, making them more appropriate to compare PET studies at different number of counts. No statistical significant differences were observed when using post-filtering and reducing the frame time to 4min (RCA50, reference 20min, phantom) and to 3min (SUVA50, reference 10min, patients). CONCLUSIONS For hybrid aminoacid brain imaging, frame duration (or injected activity) can potentially be reduced to 30% of the standard used in clinical routine without significant changes on the quantification accuracy of the PET images if adequate reconstruction settings and quantitative measures are used. Frame times below 4min in the NEMA phantom are not advisable to obtain quantitative and reproducible measures.
Collapse
|
8
|
Chen MK, Menard DH, Cheng DW. Determining the Minimal Required Radioactivity of 18F-FDG for Reliable Semiquantification in PET/CT Imaging: A Phantom Study. J Nucl Med Technol 2016; 44:26-30. [PMID: 26769598 DOI: 10.2967/jnmt.115.165258] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2015] [Accepted: 11/17/2015] [Indexed: 01/08/2023] Open
Abstract
UNLABELLED In pursuit of as-low-as-reasonably-achievable (ALARA) doses, this study investigated the minimal required radioactivity and corresponding imaging time for reliable semiquantification in PET/CT imaging. METHODS Using a phantom containing spheres of various diameters (3.4, 2.1, 1.5, 1.2, and 1.0 cm) filled with a fixed (18)F-FDG concentration of 165 kBq/mL and a background concentration of 23.3 kBq/mL, we performed PET/CT at multiple time points over 20 h of radioactive decay. The images were acquired for 10 min at a single bed position for each of 10 half-lives of decay using 3-dimensional list mode and were reconstructed into 1-, 2-, 3-, 4-, 5-, and 10-min acquisitions per bed position using an ordered-subsets expectation maximum algorithm with 24 subsets and 2 iterations and a gaussian 2-mm filter. SUVmax and SUVavg were measured for each sphere. RESULTS The minimal required activity (±10%) for precise SUVmax semiquantification in the spheres was 1.8 kBq/mL for an acquisition of 10 min, 3.7 kBq/mL for 3-5 min, 7.9 kBq/mL for 2 min, and 17.4 kBq/mL for 1 min. The minimal required activity concentration-acquisition time product per bed position was 10-15 kBq/mL⋅min for reproducible SUV measurements within the spheres without overestimation. Using the total radioactivity and counting rate from the entire phantom, we found that the minimal required total activity-time product was 17 MBq⋅min and the minimal required counting rate-time product was 100 kcps⋅min. CONCLUSION Our phantom study determined a threshold for minimal radioactivity and acquisition time for precise semiquantification in (18)F-FDG PET imaging that can serve as a guide in pursuit of achieving ALARA doses.
Collapse
Affiliation(s)
- Ming-Kai Chen
- Radiology and Biomedical Imaging, Yale University School of Medicine, New Haven, Connecticut
| | | | | |
Collapse
|
9
|
Andersson M, Mattsson S. Dose management in conventional nuclear medicine imaging and PET. Clin Transl Imaging 2015. [DOI: 10.1007/s40336-015-0150-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|