1
|
Richter A, Stukenborg-Colsman C, Plaass C. SPECT/CT of Total Ankle Arthroplasty. Clin Podiatr Med Surg 2024; 41:649-663. [PMID: 39237177 DOI: 10.1016/j.cpm.2024.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/07/2024]
Abstract
Use of SPECT/CT (Single Photon Emission Computed Tomography/Computed Tomography) is increasing providing additional information in patients with inconclusive clinical examination and unremarkable imaging findings presenting with chronic pain after total ankle arthroplasty. To differentiate the cause of pain after total ankle arthroplasty can be challenging. SPECT/CT combines structural and metabolic imaging as a hybrid tool leading to higher specificity and overall diagnostic accuracy presumably in cases of gutter impingement, prosthetic loosening, and osteoarthritis of adjacent joints. Moreover, SPECT/CT can complement diagnostic work up in periprosthetic joint infections. Basal tracer enhancement has to be considered for the interpretation of imaging findings.
Collapse
Affiliation(s)
- Alena Richter
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christina Stukenborg-Colsman
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christian Plaass
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany.
| |
Collapse
|
2
|
De Schepper S, Gnanasegaran G, De Vos W, Van de Casteele E, Dickson JC, Van den Wyngaert T. From SPECT/CT towards absolute quantification? - the case of unilateral condylar hyperplasia of the mandible. EJNMMI Phys 2024; 11:74. [PMID: 39177939 PMCID: PMC11343952 DOI: 10.1186/s40658-024-00676-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Accepted: 08/05/2024] [Indexed: 08/24/2024] Open
Abstract
BACKGROUND Unilateral condylar hyperplasia (UCH) of the mandible is a rare condition characterized by asymmetric growth of the mandibular condyles. Bone scintigraphy with SPECT(/CT) is commonly used to diagnose UCH and guide treatment. Still, varying results have been reported using the traditional threshold of 55%:45% in relative tracer uptake. While absolute quantification of uptake on SPECT/CT could improve results, optimal correction and reconstruction settings are currently unknown. METHODS Three anthropomorphic phantoms representing UCH were developed from patient CT volumes and produced using 3D printing technology. Fillable spherical inserts of different sizes (Ø: 8-15 mm) were placed in the condylar positions representing symmetrical and asymmetrical distributions. Recovery coefficients were determined for SPECT/CT using various reconstruction corrections, including attenuation and scatter correction (ACSC), resolution modeling (RM), and partial volume correction (PVC) using phantom measurements. Uptake ratios between condyles and condyle to clivus were evaluated. Finally, the impact of these correction techniques on absolute activity and diagnostic accuracy was assessed in a retrospective patient cohort for the diagnostic threshold of 55%:45%. RESULTS The activity was only partially recovered in all spherical inserts (range: 22.5-64.9%). However, RM improved relative recovery by 20.2-62.3% compared to ACSC. In the symmetric phantoms, the 95% confidence interval (CI) of condyle ratios included the diagnostic threshold (57.6%:42.4%) for UCH when using ACSC potentially leading to false positives, but not for ACSCRM datasets. Partial volume corrections coefficients from the NEMA IQ phantom was positionally dependent, with improvements seen performing PVC using coefficients derived from anthropomorphic phantoms. Retrospective application in a patient cohort showed only a weak linear correlation (R²: 0.25-0.67) and large limits of agreement (9.6-12.5%) between different reconstructions. Up to 44% of patients were reclassified using the 55%:45% threshold. Using clinical outcome data, ACSCRM had highest sensitivity (91%; 95% CI 59-100%) and specificity (66%; 95% CI 47-81%), significantly improving specificity (P = 0.038). CONCLUSIONS Anthropomorphic phantoms were shown to be essential in determining optimal settings for acquisition, reconstruction, and analysis. SPECT/CT reconstructions with attenuation and scatter correction and resolution modeling are recommended and could improve specificity when using the 55%:45% threshold to assess condylar growth.
Collapse
Affiliation(s)
- Stijn De Schepper
- Department of Nuclear Medicine, Antwerp University Hospital, Drie Eikenstraat 655, Edegem, 2650, Belgium.
- Faculty of Medicine and Health Sciences (MICA - IPPON), University of Antwerp, Wilrijk, Belgium.
| | | | - Wouter De Vos
- Department of Oral and Maxillofacial Surgery, Antwerp University Hospital, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Elke Van de Casteele
- Department of Oral and Maxillofacial Surgery, Antwerp University Hospital, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - John C Dickson
- Institute of Nuclear Medicine, University College of London Hospitals NHS, London, UK
| | - Tim Van den Wyngaert
- Department of Nuclear Medicine, Antwerp University Hospital, Drie Eikenstraat 655, Edegem, 2650, Belgium
- Faculty of Medicine and Health Sciences (MICA - IPPON), University of Antwerp, Wilrijk, Belgium
| |
Collapse
|
3
|
Ali M, Benfante V, Di Raimondo D, Laudicella R, Tuttolomondo A, Comelli A. A Review of Advances in Molecular Imaging of Rheumatoid Arthritis: From In Vitro to Clinic Applications Using Radiolabeled Targeting Vectors with Technetium-99m. Life (Basel) 2024; 14:751. [PMID: 38929734 PMCID: PMC11204982 DOI: 10.3390/life14060751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 05/24/2024] [Accepted: 06/07/2024] [Indexed: 06/28/2024] Open
Abstract
Rheumatoid arthritis (RA) is a systemic autoimmune disorder caused by inflammation of cartilaginous diarthrodial joints that destroys joints and cartilage, resulting in synovitis and pannus formation. Timely detection and effective management of RA are pivotal for mitigating inflammatory arthritis consequences, potentially influencing disease progression. Nuclear medicine using radiolabeled targeted vectors presents a promising avenue for RA diagnosis and response to treatment assessment. Radiopharmaceutical such as technetium-99m (99mTc), combined with single photon emission computed tomography (SPECT) combined with CT (SPECT/CT), introduces a more refined diagnostic approach, enhancing accuracy through precise anatomical localization, representing a notable advancement in hybrid molecular imaging for RA evaluation. This comprehensive review discusses existing research, encompassing in vitro, in vivo, and clinical studies to explore the application of 99mTc radiolabeled targeting vectors with SPECT imaging for RA diagnosis. The purpose of this review is to highlight the potential of this strategy to enhance patient outcomes by improving the early detection and management of RA.
Collapse
Affiliation(s)
- Muhammad Ali
- Ri.MED Foundation, Via Bandiera 11, 90133 Palermo, Italy; (M.A.); (A.C.)
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Molecular and Clinical Medicine, University of Palermo, 90127 Palermo, Italy; (D.D.R.); (A.T.)
| | - Viviana Benfante
- Ri.MED Foundation, Via Bandiera 11, 90133 Palermo, Italy; (M.A.); (A.C.)
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Molecular and Clinical Medicine, University of Palermo, 90127 Palermo, Italy; (D.D.R.); (A.T.)
| | - Domenico Di Raimondo
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Molecular and Clinical Medicine, University of Palermo, 90127 Palermo, Italy; (D.D.R.); (A.T.)
| | - Riccardo Laudicella
- Nuclear Medicine Unit, Department of Biomedical and Dental Sciences and Morpho-Functional Imaging, Messina University, 98124 Messina, Italy;
| | - Antonino Tuttolomondo
- Department of Health Promotion, Mother and Child Care, Internal Medicine and Medical Specialties, Molecular and Clinical Medicine, University of Palermo, 90127 Palermo, Italy; (D.D.R.); (A.T.)
| | - Albert Comelli
- Ri.MED Foundation, Via Bandiera 11, 90133 Palermo, Italy; (M.A.); (A.C.)
- NBFC—National Biodiversity Future Center, 90133 Palermo, Italy
| |
Collapse
|
4
|
Wang Y, Zha Y, Liu L, Liao A, Dong Z, Roberts N, Li Y. Single photon emission computed tomography/computed tomography imaging of gouty arthritis: A new voice. J Transl Int Med 2024; 12:215-224. [PMID: 39081275 PMCID: PMC11284626 DOI: 10.2478/jtim-2022-0066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2023] Open
Abstract
Gouty arthritis, often referred to simply as gout, is a disorder of purine metabolism characterized by the deposition of monosodium urate monohydrate (MSU) crystals in multiple systems and organs, especially in joints and their surrounding soft tissue. Gout is a treatable chronic disease, and the main strategy for effective management is to reverse the deposition of MSU crystals by uric acid reduction, and to prevent gout attacks, tophi deposition and complications, and thereby improve the quality of life. However, the frequent association of gout with other conditions such as hypertension, obesity, cardiovascular disease, diabetes, dyslipidemia, chronic kidney disease (CKD) and kidney stones can complicate the treatment of gout and lead to premature death. Here, we review the use of medical imaging techniques for studying gouty arthritis with special interest in the potential role of single photon emission computed tomography (SPECT)/computed tomography (CT) in the clinical management of gout and complications (e.g., chronic kidney disease and cardiovascular disease).
Collapse
Affiliation(s)
- Yan Wang
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| | - Yan Zha
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
- Departnent of Nephrology, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| | - Lin Liu
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
- Department of Respiratory and Critical Care Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| | - Ang Liao
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| | - Ziqiang Dong
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| | - Neil Roberts
- School of Clinical Sciences, The Queen’s Medical Research Institute, University of Edinburgh, EdinburghEH8 9YL , United Kingdom
| | - Yaying Li
- Department of Nuclear Medicine, Guizhou Provincial People's Hospital, Affiliated Hospital of Guizhou University, Guiyang 550002, Guizhou Province, China
| |
Collapse
|
5
|
Wang R, Huang Z, Xiao Y, Huang T, Ming J. Photothermal therapy of copper incorporated nanomaterials for biomedicine. Biomater Res 2023; 27:121. [PMID: 38001505 PMCID: PMC10675977 DOI: 10.1186/s40824-023-00461-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 11/07/2023] [Indexed: 11/26/2023] Open
Abstract
Studies have reported on the significance of copper incorporated nanomaterials (CINMs) in cancer theranostics and tissue regeneration. Given their unique physicochemical properties and tunable nanostructures, CINMs are used in photothermal therapy (PTT) and photothermal-derived combination therapies. They have the potential to overcome the challenges of unsatisfactory efficacy of conventional therapies in an efficient and non-invasive manner. This review summarizes the recent advances in CINMs-based PTT in biomedicine. First, the classification and structure of CINMs are introduced. CINMs-based PTT combination therapy in tumors and PTT guided by multiple imaging modalities are then reviewed. Various representative designs of CINMs-based PTT in bone, skin and other organs are presented. Furthermore, the biosafety of CINMs is discussed. Finally, this analysis delves into the current challenges that researchers face and offers an optimistic outlook on the prospects of clinical translational research in this field. This review aims at elucidating on the applications of CINMs-based PTT and derived combination therapies in biomedicine to encourage future design and clinical translation.
Collapse
Affiliation(s)
| | | | | | - Tao Huang
- Department of Breast and Thyroid Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.
| | - Jie Ming
- Department of Breast and Thyroid Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277 Jiefang Avenue, Wuhan, 430022, People's Republic of China.
| |
Collapse
|
6
|
Richter A, Stukenborg-Colsman C, Plaass C. SPECT/CT of Total Ankle Arthroplasty. Foot Ankle Clin 2023; 28:493-507. [PMID: 37536815 DOI: 10.1016/j.fcl.2023.04.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/05/2023]
Abstract
Use of SPECT/CT (Single Photon Emission Computed Tomography/Computed Tomography) is increasing providing additional information in patients with inconclusive clinical examination and unremarkable imaging findings presenting with chronic pain after total ankle arthroplasty. To differentiate the cause of pain after total ankle arthroplasty can be challenging. SPECT/CT combines structural and metabolic imaging as a hybrid tool leading to higher specificity and overall diagnostic accuracy presumably in cases of gutter impingement, prosthetic loosening, and osteoarthritis of adjacent joints. Moreover, SPECT/CT can complement diagnostic work up in periprosthetic joint infections. Basal tracer enhancement has to be considered for the interpretation of imaging findings.
Collapse
Affiliation(s)
- Alena Richter
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christina Stukenborg-Colsman
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany
| | - Christian Plaass
- Department for Foot and Ankle surgery, DIAKOVERE Annastift, Orthopedic Clinic of the Hannover Medical School, Anna-von-Borries Strasse 1-7, Hannover 30625, Germany.
| |
Collapse
|
7
|
Anzola LK, Hernandez N, Rodriguez LF, Sanguino G, Martinez E, Lopez R, Moreno S, Prill R, Mut F, Rasch H, Hirschmann M. The role of SPECT/CT in painful, noninfected knees after knee arthroplasty: a systematic review and meta-analysis-a diagnostic test accuracy review. J Orthop Surg Res 2023; 18:223. [PMID: 36945001 PMCID: PMC10031962 DOI: 10.1186/s13018-023-03687-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 03/07/2023] [Indexed: 03/23/2023] Open
Abstract
PURPOSE The aim of this systematic review was to present the current evidence on the clinical use of single-photon emission computed tomography/computed tomography (SPECT/CT) in the evaluation of noninfected painful knees after knee arthroplasty. METHODS Embase, PubMed, Google Scholar, Ovid, Scopus, Science Direct and the Cochrane Database of Systematic Reviews were searched from database inception to May 2022 following the PRISMA guidelines. As a primary outcome, we defined the role of SPECT/CT in the diagnostic approach to noninfected painful knee arthroplasty; as a secondary objective, we described the noninfection-related factors linked to painful knee arthroplasty. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio values and other indicators were calculated; receiver operating characteristic (ROC) curve analysis results and a summary of the areas under the curve (AUCs) from the included studies were reported. A Fagan plot, likelihood ratio plot and Deeks' funnel plot were generated and analysed. Methodological quality was assessed using the QUADAS-2 tool, and the certainty of evidence was assessed by the GRADE approach. RESULTS A total of 493 publications were identified, of which eight met the inclusion criteria, with a final pooled sample size of 308 patients. The pooled sensitivity and specificity of SPECT/CT in diagnosing the source of pain in painful knee prostheses were 0.86 (95% CI: 0.75-0.93) and 0.90 (95% CI: 0.79-0.96), respectively, with pooled +LR and -LR values of 8.9 (95% CI: 4.11-19.19) and 0.15 (95% CI: 0.09-0.28). The pooled diagnostic odds ratio was 57.35, and the area under the curve was 0.94. SPECT/CT highly accurately identified different sources of pain, such as loosening of the prosthetic components, patellofemoral overloading, instability, malalignment of the components and degeneration of the patellofemoral compartment. The confidence of the estimates was moderate according to the GRADE approach. CONCLUSION With demonstrated high sensitivity and specificity, as a diagnostic tool, SPECT/CT can identify the source of pain in painful knees after knee arthroplasty, particularly in cases of loosening, patellofemoral disorders and component malalignment (level of evidence III). These findings have significant clinical repercussions, such as in changing the initial diagnosis, identifying or excluding different causes of painful knee arthroplasties, guiding subsequent treatment and positively impacting the final clinical outcome. We moderately recommend the use of SPECT/CT for identifying the source of pain after knee arthroplasty according to the GRADE assessment. This review was preregistered in Prospero under code CRD42022320457.
Collapse
Affiliation(s)
- Luz Kelly Anzola
- Department of Nuclear Medicine, Clinica Reina Sofia, Bogota, Colombia.
- Department of Nuclear Medicine, Clinica Colombia, Bogota, Colombia.
- Fundacion Universitaria Sanitas Nuclear Medicine Postgraduate Program, Bogota, Colombia.
| | - Nathaly Hernandez
- Fundacion Universitaria Sanitas Nuclear Medicine Postgraduate Program, Bogota, Colombia
| | | | - Gilberto Sanguino
- Department of Orthopedics and Traumatology, Clinica Reina Sofia, Bogota, Colombia
| | - Ernesto Martinez
- Department of Orthopedics and Traumatology, Clinica Reina Sofia, Bogota, Colombia
| | - Rodrigo Lopez
- Department of Orthopedics and Traumatology, Clinica Reina Sofia, Bogota, Colombia
| | - Sergio Moreno
- Clinical Epidemiologist, Universidad Nacional de Colombia, Bogota, Colombia
| | - Robert Prill
- Center of Orthopaedics and Traumatology, University Hospital Brandenburg/Havel, Brandenburg Medical School Theodore Fontane, Neuruppin, Germany
| | - Fernando Mut
- Department of Nuclear Medicine, Hospital Italiano, Montevideo, Uruguay
| | - Helmut Rasch
- Institute for Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
| | - Michael Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
| |
Collapse
|
8
|
Boero M, Allocca M, Pisu N, Sanna S, Ruggiero A, Pung BLJ, Margotti S, Dessì G. Management of periprosthetic knee joint infections: focus on the role of Nuclear Medicine (v2). Orthop Rev (Pavia) 2022; 14:39646. [PMID: 36381502 PMCID: PMC9662607 DOI: 10.52965/001c.39646] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND When faced with a painful knee replacement, ruling out infection is mandatory to set the correct therapeutic approach. However, it is not always easy, especially in subclinical/chronic infections. A multidisciplinary approach is necessary to assess in the most correct way each case of suspected periprosthetic knee joint infection. This review explores the role of nuclear medicine investigations in the management of periprosthetic knee infections and their proper use within a multidisciplinary pathway. METHODS A PubMed search was conducted selecting studies from the past 10 years. RESULTS Triphasic bone scintigraphy has high sensitivity (93%) but poor specificity (56%) for periprosthetic joint infections of the knee, with a high negative predictive value (NPV), ranging from 96% to 100%. Consequently, a negative bone scan is useful in ruling out infection. In contrast, radiolabeled leukocyte scintigraphy is characterized by a sensitivity of 85.7-93%, specificity of 93.6-100%, diagnostic accuracy of 92.6-98%, NPV of 93-97.8%, and positive predictive value (PPV) of 66.7-100%. By adding a tomographic acquisition with hybrid single-photon emission computed tomography combined with computed tomography technique (SPECT/CT), the diagnostic accuracy increases. Because 18F-fluorodeoxyglucose (FDG) accumulates at both sites of inflammation and infection, FDG positron emission tomography (PET/CT) shows low specificity. CONCLUSIONS A common decision-making process in the diagnosis of periprosthetic joint infection is not yet validated and multidisciplinary integration is mandatory. In this context, nuclear medicine can contribute decisively.
Collapse
Affiliation(s)
| | | | - Nicola Pisu
- Nuclear Medicine, Brotzu Hospital, Cagliari (Italy)
| | - Silvia Sanna
- Nuclear Medicine, Brotzu Hospital, Cagliari (Italy)
| | | | | | | | | |
Collapse
|
9
|
Cutting-Edge Approaches in Arthroplasty: Before, during and after Surgery. J Pers Med 2022; 12:jpm12101671. [PMID: 36294810 PMCID: PMC9605126 DOI: 10.3390/jpm12101671] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 09/29/2022] [Indexed: 12/02/2022] Open
Abstract
Personalised medicine was introduced in arthroplasty a long time ago with the aim of respecting each individual person for their unique personal characteristics in order to further improve outcomes [...].
Collapse
|
10
|
Daggett SM, Cantarelli T, Gyftopoulos S, Krueger P, Ross AB. Cost-effectiveness Analysis in Diagnostic Musculoskeletal Radiology: A Systematic Review. Curr Probl Diagn Radiol 2022; 52:20-24. [DOI: 10.1067/j.cpradiol.2022.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 07/27/2022] [Indexed: 11/22/2022]
|
11
|
Hothi H, Cerquiglini A, Büel L, Henckel J, Moser LB, Hirschmann MT, Hart A. SPECT/CT Assessment of In-Vivo Loading of the Knee Correlates with Polyethylene Deformation in Retrieved Total Knee Arthroplasty. Tomography 2022; 8:180-188. [PMID: 35076625 PMCID: PMC8788541 DOI: 10.3390/tomography8010015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 12/18/2021] [Accepted: 01/02/2022] [Indexed: 11/16/2022] Open
Abstract
Background: SPECT/CT distribution patterns in patients with total knee replacements have previously been correlated with factors such as time of implantation, implant type and alignment. It is unknown, however, if an increased and more extended bone tracer uptake (BTU) in SPECT/CT, representing loading of the joint, correlates with findings from retrieval studies. The aim of this study was to further understand this subject. Materials and Methods: 62 retrieved TKA were included. SPECT/CT was performed prior to revision. Quantitative and qualitative medio-lateral comparisons of BTU intensity and distribution in the tibia were performed. Retrieval analysis was performed with a micro-CT method to assess the thickness differences between medial and lateral sides of polyethylene inserts with symmetrical designs. Results: In the subgroup of TKA with asymmetrical SPECT/CT distribution, there was a significant correlation between retrieval and medical imaging data (p = 0.0355): patients showing a more extended BTU in the medial compartment also had a significantly thinner insert in the medial compartment, and vice versa in the lateral side. Conclusion: This is the first study comparing BTU distribution patterns and retrieval findings. Our results support the hypothesis that SPECT/CT is able to identify bone activity due to implant position and loading.
Collapse
Affiliation(s)
- Harry Hothi
- The Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK; (A.C.); (J.H.); (A.H.)
- Correspondence:
| | - Arianna Cerquiglini
- The Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK; (A.C.); (J.H.); (A.H.)
| | - Lukas Büel
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101 Bruderholz, Switzerland; (L.B.); (L.B.M.); (M.T.H.)
- Department of Orthopaedics, University of Basel, 4001 Basel, Switzerland
| | - Johann Henckel
- The Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK; (A.C.); (J.H.); (A.H.)
| | - Lukas B. Moser
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101 Bruderholz, Switzerland; (L.B.); (L.B.M.); (M.T.H.)
| | - Michael T. Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101 Bruderholz, Switzerland; (L.B.); (L.B.M.); (M.T.H.)
| | - Alister Hart
- The Royal National Orthopaedic Hospital, Stanmore HA7 4LP, UK; (A.C.); (J.H.); (A.H.)
| |
Collapse
|
12
|
Gamma camera imaging (bone scan) in orthopedics: Foot, ankle, knees, and hip. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00214-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
13
|
Abstract
BACKGROUND Single photon emission computed tomography (SPECT/CT) is a diagnostic option for knee osteoarthritis patients without osteoarthritic features on X-ray; however, the added value of SPECT/CT remains debatable in the diagnostic algorithm. OBJECTIVE To review the added value of SPECT/CT in the diagnostic algorithm of knee osteoarthritis. STUDY DESIGN Systematic review. METHODS A systematic search was carried out in the databases EMBASE, MEDLINE, and the Cochrane collaboration. The retrieved articles were screened for relevance on title and abstract. This was followed by a full-text study quality appraisal of the remaining articles. Finally, a total of 9 trials were included. RESULTS The use of SPECT/CT might objectify some clinical knee osteoarthritis symptoms. It could correlate with findings on plain radiography and magnetic resonance imaging. Furthermore, there is some evidence SPECT/CT gives additional information compared with these imaging modalities; however, superiority is not proven. The uptake on SPECT could predict the intraoperative macroscopic findings. Yet the clinical relevance remains unclear. CONCLUSION There is no strong evidence SPECT/CT should play a role in the diagnosing and decision-making processes of knee osteoarthritis. Yet there is evidence suggesting SPECT/CT might give additional information in the diagnosing process. More research would be of added value to answer this research question.
Collapse
Affiliation(s)
- D. Zarringam
- Department of Orthopaedics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| | - D.B.F. Saris
- Department of Orthopedic Surgery and Sports Medicine, Mayo Clinic, Rochester, MN, USA
| | - J.E.J. Bekkers
- Department of Orthopedics, Diakonessenhuis Hospital, Utrecht, The Netherlands,J. E. J. Bekkers, Clinical Orthopedic Research Center–midden Nederland (CORC-mN), Department of Orthopedics, Diakonessenhuis Hospital, Bosboomstraat 1, Utrecht, 3582 KE, The Netherlands.
| |
Collapse
|
14
|
A New Strategy for Rapid Diagnosis of the Source of Low Back Pain in Patients Scheduled to Undergo Treatment with Cooled Radiofrequency Ablation. Diagnostics (Basel) 2021; 11:diagnostics11101822. [PMID: 34679520 PMCID: PMC8534588 DOI: 10.3390/diagnostics11101822] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 01/07/2023] Open
Abstract
Objective: The objective of this study was to develop a new strategy for rapid diagnosis of the source of low back pain (LBP) for treatment with cooled radiofrequency ablation (RFA). Materials: Patients suffering from facet joint (FJ) or sacroiliac joint (SIJ) pain for more than 3 months were included. Two methods, Technetium Tc99m methylene diphosphonate single photon emission tomography/computed tomography (99mTc-MDP SPECT/CT) and a modified Fortin finger test were used to identify the source of LBP for treatment with cooled RFA. The visual analog scale (VAS) and Oswestry disability index (ODI) were used to assess the patients’ pain levels and disabilities respectively. These two measures were recorded at baseline and 1-week, 1-month, 3-month, and 6-month follow-up visits. Results: A total of 40 patients with LBP were included in this study. Our results demonstrated that the patients with LBP identified by our new strategy had significant improvements in VAS or ODI score at 1-week to 6-month follow-up visits (p < 0.001) after receiving cooled RFA. Similar results were also found in patients with FJ pain and those with FJ and SIJ pain respectively. Among all the patients, over 70% had greater than or equal to 50% reduction in VAS and ODI scores. No serious adverse events were observed after treatment. Conclusions: This new strategy could be successfully adopted for rapid diagnosis of the source of comprehensive LBP.
Collapse
|
15
|
Zhou AK, Girish M, Thahir A, Lim JA, Chen X, Krkovic M. Radiological evaluation of postoperative osteomyelitis in long bones: Which is the best tool? J Perioper Pract 2021; 32:15-21. [PMID: 33719739 PMCID: PMC8750142 DOI: 10.1177/1750458920961347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Currently, definitive diagnosis of osteomyelitis involves a combination of clinical signs, symptoms, laboratory tests, imaging modalities and cultures from blood, joint or body fluid. Imaging plays a critical role in the osteomyelitis diagnosis. Each of these tests incurs an additional cost to the patient or healthcare system and their use varies according to the preference of the healthcare professional and the healthcare setup. Imaging plays a critical role in the diagnosis and management of postoperative long bone osteomyelitis, with the aim of reducing long-term complications such as non-union, amputation and pathological fractures. In this review, we discuss the key findings on different radiological modalities and correlate them with disease pathophysiology. Currently, magnetic resonance imaging is the best available imaging modality due to its sensitivity in detecting early signs of long bone osteomyelitis and high soft tissue resolution. Other modalities such as radio-nuclear medicine, computed tomography and ultrasound have been proved to be useful in different clinical scenarios as described in this narrative review.
Collapse
Affiliation(s)
- Andrew Kailin Zhou
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK.,School of Clinical Medicine, University of Cambridge, Cambridge, UK
| | - Milind Girish
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK.,School of Clinical Medicine, University of Cambridge, Cambridge, UK
| | - Azeem Thahir
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK
| | - Jiang An Lim
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK.,School of Clinical Medicine, University of Cambridge, Cambridge, UK
| | - Xiaoyu Chen
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK.,School of Clinical Medicine, University of Cambridge, Cambridge, UK
| | - Matija Krkovic
- Department of Trauma and Orthopaedics, Addenbrookes Major Trauma Unit, Cambridge University Hospitals, Cambridge, UK
| |
Collapse
|
16
|
Abstract
» A 3-phase bone scan is a potential first-line nuclear medicine study for pain after total joint arthroplasty (TJA) when there is concern for periprosthetic joint infection or aseptic loosening. » In patients who have a positive bone scintigraphy result and suspected infection of the joint, but where aspiration or other studies are inconclusive, labeled leukocyte scintigraphy with bone marrow imaging may be of benefit. » Magnetic resonance imaging (MRI), while not a nuclear medicine study, also shows promise and has the advantage of providing information about the soft tissues around a total joint replacement. » Radiotracer uptake patterns in scintigraphy are affected by the prosthesis (total knee arthroplasty [TKA] versus total hip arthroplasty [THA]) and the use of cement. » Nuclear medicine scans may be ordered 1 year postoperatively but may have positive findings that are due to normal physiologic bone remodeling. Nuclear studies may be falsely positive for up to 2 years after TJA. » Single-photon emission computed tomography (SPECT) combined with computed tomography (CT) (SPECT/CT), fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT, and MRI show promise; however, more studies are needed to better define their role in the diagnostic workup of pain after TJA.
Collapse
Affiliation(s)
- John M Pinski
- Department of Orthopedic Surgery, Tufts Medical Center, Boston, Massachusetts
| | - Antonia F Chen
- Department of Orthopedic Surgery, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts
| | - Daniel M Estok
- Department of Orthopedic Surgery, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts
| | - Joseph J Kavolus
- Department of Orthopedic Surgery, Tufts Medical Center, Boston, Massachusetts
| |
Collapse
|
17
|
Mohd Rohani MF, Zanial AZ, Suppiah S, Phay Phay K, Mohamed Aslum Khan F, Mohamad Najib FH, Mohd Noor N, Arumugam M, Amir Hassan SZ, Vinjamuri S. Bone single-photon emission computed tomography/computed tomography in cancer care in the past decade: a systematic review and meta-analysis as well as recommendations for further work. Nucl Med Commun 2021; 42:9-20. [PMID: 33165258 DOI: 10.1097/mnm.0000000000001306] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Skeletal whole-body scintigraphy (WBS), although widely used as a sensitive tool for detecting metastatic bone disease in oncology cases, has relatively low specificity. Indeterminate bone lesions (IBLs) detected by WBS cause a diagnostic dilemma, which hampers further management plans. In the advent of hybrid imaging, single-photon emission computed tomography/computed tomography (SPECT/CT) has been gaining popularity as a tool to improve the characterisation of IBLs detected by WBS. As yet, there has not been a systematic review to objectively evaluate the diagnostic capabilities of SPECT/CT in this area. We conducted a systematic review of relevant electronic databases up to 30 August 2020. The outcomes of interest were the reporting of SPECT/CT to identify benign and malignant IBLs and the calculation of the sensitivity and specificity of the index test, based on histopathological examination or clinical and imaging follow-up as the reference standard. After the risk of bias and eligibility assessment, 12 articles were identified and synthesised in the meta-analysis. The pooled sensitivity and specificity of SPECT/CT for diagnosing IBLs are 93.0% [95% confidence interval (CI) 0.91-0.95] and 96.0% (95% CI 0.94-0.97), respectively. There was heterogeneity of the articles due to variable imaging protocols, duration of follow-up and scoring methods for interpreting the SPECT/CT results. The heterogeneity poses a challenge for accurate interpretation of the true diagnostic capability of SPECT/CT. In conclusion, targeted SPECT/CT improves the specificity of diagnosing bone metastases, but efforts need to be made to standardise the thresholds for SPECT/CT, methodology, as well as harmonising the reporting and interpretation criteria. We also make some recommendations for future works.
Collapse
Affiliation(s)
| | | | - Subapriya Suppiah
- Department of Nuclear Medicine, Hospital Kuala Lumpur
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia
| | | | | | | | - Noramaliza Mohd Noor
- Department of Radiology, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia
| | - Manohar Arumugam
- Department of Orthopaedic, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, Malaysia
| | | | - Sobhan Vinjamuri
- Department of Nuclear Medicine, The Royal Liverpool and Broadgreen University Hospitals, NHS Trust, Liverpool, UK
| |
Collapse
|
18
|
Lima TVM, Bhure U, Pérez Lago MDS, Thali Y, Matijasevic S, Roos J, Strobel K. Impact of metal implants on xSPECT/CT Bone reconstruction: the "shining metal artefact". Eur J Hybrid Imaging 2020; 4:18. [PMID: 34191170 PMCID: PMC8218054 DOI: 10.1186/s41824-020-00087-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Accepted: 08/17/2020] [Indexed: 11/29/2022] Open
Abstract
Background Novel reconstruction algorithms, such as xSPECT Bone, are gaining more and more importance in Nuclear Medicine. With xSPECT Bone, the reconstructed emission image is enhanced by the information obtained in the corresponding CT image. The CT defines tissue classes according to the Hounsfield units. In the iterative reconstruction, each tissue class is handled separately in the forward projection step, and all together in the back projection step. As a consequence, xSPECT Bone reconstruction generates images with improved boundary delineation and better anatomic representation of tracer activity. Applying this technique, however, showed that artefacts may occur, when no uptake regions, like metal implants, exhibit fictitious uniform tracer uptake. Due to limitations in spatial resolution in gamma cameras, the xSPECT Bone reconstructed image resulted in spill-out activity from surrounding high uptake region being uniformly distributed over the metal implants. This new technology of xSPECT Bone reconstruction in general enhances the image quality of SPECT/CT; however, the potential introduction of specific artefacts which inadvertently come along with this new technology and their frequency have not yet been addressed in the literature. Therefore, the purpose of this work was to identify and characterize these specific metal artefacts (the so-called shining metal artefact) in order to reduce false positives and avoid potentially misdiagnosing loosened or infected implants. Case presentation In this work, we report five cases imaged with bone SPECT/CT of 5 anatomical regions (foot, elbow, spine, shoulder, ribs and knee). All cases demonstrated “shining metal artefacts” in xSPECT Bone reconstruction. Conclusion While xSPECT Bone reconstruction algorithm significantly improves image quality for the diagnosis of bone and joint disorders with SPECT/CT, specific “shining metal artefacts” caused by the xSPECT Bone have to be recognized in order to avoid image misinterpretation suggesting metallic implant loosening or possible infection. The simultaneous analysis of conventionally reconstructed SPECT images (for Siemens the Flash3D reconstruction) helps to avoid misinterpretation of potential artefacts introduced by xSPECT Bone reconstruction.
Collapse
Affiliation(s)
- Thiago V M Lima
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland. .,Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
| | - Ujwal Bhure
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland
| | | | - Yannick Thali
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Savo Matijasevic
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Justus Roos
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland
| | - Klaus Strobel
- Radiologie und Nuklearmedizin, Luzerner Kantonsspital, Lucerne, Switzerland
| |
Collapse
|
19
|
Van den Wyngaert T, Elvas F, De Schepper S, Kennedy JA, Israel O. SPECT/CT: Standing on the Shoulders of Giants, It Is Time to Reach for the Sky! J Nucl Med 2020; 61:1284-1291. [PMID: 32620702 DOI: 10.2967/jnumed.119.236943] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Accepted: 05/28/2020] [Indexed: 12/11/2022] Open
Abstract
Twenty years ago, SPECT/CT became commercially available, combining the strengths of both techniques: the diagnostic sensitivity of SPECT and the anatomic detail of CT. Other benefits initially included attenuation correction of SPECT reconstructions, ultimately evolving to correction techniques that would enable absolute tracer uptake quantification. Recent developments in SPECT hardware include solid-state digital systems with higher sensitivity and resolution, using novel collimator designs based on tungsten. Similar advances in CT technology have been introduced in hybrid SPECT/CT systems, replacing low-end x-ray tubes with high-end multislice CT scanners equipped with iterative reconstruction, metal artifact reduction algorithms, and dual-energy capabilities. More recently, the design of whole-body SPECT/CT systems has taken another major leap with the introduction of a ring-shaped gantry equipped with multiple movable detectors surrounding the patient. These exciting developments have fueled efforts to develop novel SPECT radiopharmaceuticals, creating new chelators and prosthetic groups for radiolabeling. Innovative SPECT radionuclide pairs have now become available for radiolabeling with the potential for use as theranostic agents. The growth of precision medicine and the associated need for accurate radionuclide treatment dosimetry will likely drive the use of SPECT/CT in the near future. In addition, expanding clinical applications of SPECT/CT in other areas such as orthopedics offer exciting opportunities. Although it is true that the SPECT/CT ecosystem has seen several challenges during its development over the past 2 decades, it is now a feature-rich and mature tool ready for clinical prime time.
Collapse
Affiliation(s)
- Tim Van den Wyngaert
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium .,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Filipe Elvas
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium.,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - Stijn De Schepper
- Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium.,Integrated Personalized and Precision Oncology Network, Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium
| | - John A Kennedy
- Department of Nuclear Medicine, Rambam Healthcare Campus, Haifa, Israel; and.,Rappaport School of Medicine, Israel Institute of Technology, Haifa, Israel
| | - Ora Israel
- Rappaport School of Medicine, Israel Institute of Technology, Haifa, Israel
| |
Collapse
|
20
|
Murer AM, Hirschmann MT, Amsler F, Rasch H, Huegli RW. Bone SPECT/CT has excellent sensitivity and specificity for diagnosis of loosening and patellofemoral problems after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2020; 28:1029-1035. [PMID: 31263926 DOI: 10.1007/s00167-019-05609-w] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 06/26/2019] [Indexed: 12/31/2022]
Abstract
PURPOSE The primary purpose of this retrospective study with prospectively collected data was to evaluate the clinical value of SPECT/CT, in particular its impact on clinical diagnosis and patient management, in patients with pain, stiffness, or swelling after primary total knee arthroplasty (TKA). The secondary purpose was to determine the sensitivity and the specificity of SPECT/CT for different pathologies such as loosening and patellofemoral overloading. METHODS A retrospective analysis was carried out on 214 knees in 202 consecutive patients (mean age 69 ± 11 years) with persistent or recurrent knee pain after TKA. All patients underwent clinical examination, standardised radiographs, and 99mTc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnoses before and after SPECT/CT and final treatment were recorded. TKA component position was routinely measured on 3D-reconstructed images. Intensity and anatomical distribution of bone tracer uptake were determined. RESULTS SPECT/CT changed the clinical diagnosis and final treatment in 139/214 (65%) knees. In 117 (54.7%) out of 214 patients, revision surgery was proposed following SPECT/CT. Early onset of pain was significantly (p = 0.011) correlated with tibiofemoral stress pattern in SPECT/CT. A total of 86 knees (40.2%) were surgically revised using semi-constrained or fully constrained TKA. In 35 patients, a secondary patellar resurfacing was performed. SPECT/CT showed the clinical diagnosis to be incorrect for suspicion of tibial component loosening in 56 patients (26.2%), femoral component loosening in 53 patients (24.8%), and patellofemoral overloading/progressive patellofemoral osteoarthritis in 26 patients (12.1%) and provided different underlying causes of persistent knee pain after TKA. Likewise, SPECT/CT identified tibial component loosening in 8 patients (3.7%), femoral component loosening in 4 patients (1.9%), and patellofemoral OA in 71 patients (33.2%) without prior clinical suspected diagnosis. The sensitivity and specificity of SPECT/CT for detection of patellofemoral OA was 96.5% and 96.2%, respectively. The sensitivity and specificity for detection of tibial component loosening was 96.0% and 100%, respectively. The sensitivity and specificity for detection of femoral component loosening was 95.0% and 100%, respectively. CONCLUSION The diagnostic benefits of SPECT/CT in the challenging and complex cohort of patients with pain after primary TKA have been proven. The excellent sensitivity and specificity for detection of tibial or femoral component loosening and diagnosis of patellofemoral OA have been surgically confirmed. Due to the benefits in establishing the correct diagnosis, SPECT/CT should be implemented as part of the routine diagnostic algorithm for patients with pain after primary TKA. LEVEL OF EVIDENCE II.
Collapse
Affiliation(s)
- Andreas M Murer
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland
- University of Basel, Basel, Switzerland
| | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland.
- University of Basel, Basel, Switzerland.
| | | | - Helmut Rasch
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
| | - Rolf W Huegli
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland
- University of Basel, Basel, Switzerland
| |
Collapse
|
21
|
Schröder FF, Post CE, Wagenaar FCBM, Verdonschot N, Huis In't Veld RMHA. MRI as Diagnostic Modality for Analyzing the Problematic Knee Arthroplasty: A Systematic Review. J Magn Reson Imaging 2019; 51:446-458. [PMID: 31332865 PMCID: PMC7003732 DOI: 10.1002/jmri.26874] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Revised: 07/05/2019] [Accepted: 07/05/2019] [Indexed: 12/13/2022] Open
Abstract
Background Various diagnostic modalities are available to assess the problematic knee arthroplasty. Visualization of soft‐tissue structures in relation to the arthroplasty and bone remains difficult. Recent developments in MRI sequences could make MRI a viable addition to the diagnostic arsenal. Purpose To review the diagnostic properties of MRI, to identify certain causes of complaints that may be directly related to implant failure of total (TKA) or unicompartmental knee arthroplasty (UKA); infection, loosening and wear, instability, malalignment, arthrofibrosis, or patellofemoral problems. Study Type Systematic review. Population Twenty‐three studies were included: 16 TKA, four UKA, and three cadaveric studies. Causes of knee arthroplasty complaints analyzed were; infection (three), loosening and wear (11), malalignment (five) and instability (four). Field Strength and Sequences No field strength or sequence restrictions. Assessment PubMed, SCOPUS, and EMBASE were searched. Risk of bias was assessed using the COnsensus‐based Standards for the selection of health Measurement Instruments (COSMIN) and the QUality Assessment of Diagnostic Accuracy Studies‐2 (QUADAS‐2). Statistical Tests The results of the original research articles are stated. Results Fifteen studies assessed the reproducibility of analyzing infection, loosening and wear, and malalignment. Fourteen of 15 studies were deemed as adequate to good quality. Results showed a moderate to excellent agreement (ICC/K 0.55–0.97). Fourteen studies addressed the accuracy. For infection and loosening and wear the sensitivity and specificity estimates varied between 0.85–0.97 and 0.70–1.00, respectively. The accuracy for malalignment was excellent (r ≥ 0.81). For these studies QUADAS‐2 analysis suggested few risks of bias. A meta‐analysis was not possible due to the heterogeneity of the data. Data Conclusion This study supports that MRI can be used with overall reproducible and accurate results for diagnosing infection, loosening and wear, and malalignment after knee arthroplasty. Nonetheless, studies regarding the diagnosis of instability, arthrofibrosis or patellofemoral complaints using MRI are limited and inconclusive. Level of Evidence: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:446–458.
Collapse
Affiliation(s)
- Femke F Schröder
- The OCON, Centre for Orthopaedic Surgery, Hengelo, The Netherlands.,University of Twente, Faculty of Engineering Technology, Biomechanical Engineering, The Netherlands
| | - Corine E Post
- The OCON, Centre for Orthopaedic Surgery, Hengelo, The Netherlands.,University of Twente, Faculty of Engineering Technology, Biomechanical Engineering, The Netherlands.,Orthopaedic Research Laboratory, Radboud University Medical Center, The Netherlands
| | | | - Nico Verdonschot
- University of Twente, Faculty of Engineering Technology, Biomechanical Engineering, The Netherlands.,Orthopaedic Research Laboratory, Radboud University Medical Center, The Netherlands
| | | |
Collapse
|
22
|
Ammann N, Schiapparelli FF, Moser LB, Rasch H, Amsler F, Hirschmann MT. Good correlation between bone tracer uptake in SPECT/CT and intraoperative findings of chondral lesions graded with the ICRS scoring. J Orthop Res 2019; 37:522-528. [PMID: 30378184 DOI: 10.1002/jor.24171] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 10/15/2018] [Indexed: 02/04/2023]
Abstract
The question if bone tracer uptake in SPECT/CT reflects the intraoperative cartilage status of the knee is still unanswered. In this study, thirty-three consecutive patients (male:female = 11:22; mean age ± standard deviation 61 ± 15) with bi- or tri-compartmental knee osteoarthritis who underwent SPECT/CT before total knee arthroplasty (TKA) were collected. The knee was graded in eleven different anatomical regions. In each region, the maximal relative bone tracer uptake (mrBTU) was measured twice by two observers with a six weeks interval. The intraclass correlation coefficients (ICC) showed excellent correlations and mean values were used. Intraoperatively every region was assessed with the macroscopic International Cartilage Repair Society (ICRS) scoring. A factorial analysis and a non-parametrical Spearman's correlation were calculated among the 11 knee regions on both mrBTU and ICRS scores and significant correlations were seen between regions belonging to the same knee compartment (p < 0.05). A non-parametrical Spearman's correlation was also performed to investigate the correlation between rmBTU in SPECT/CT and intraoperative ICRS cartilage grading. Significant correlations were seen on the medial compartment, on the proximal femoral trochlea and on the medial patellar facet (p < 0.05). A significant correlation between SPECT/CT and intraoperative findings was so demonstrated in several regions. The low accuracy of the macroscopic ICRS scoring system on grade I-II lesions could have affected the missing correlations on the lateral compartment since the selected presented mainly a varus gonarthrosis. The use of an objective measure as the rmBTU could overcome the limit of the subjectivity of MRI findings in early osteoarthritis. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:522-528, 2019.
Collapse
Affiliation(s)
- Nora Ammann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), CH-4101 Bruderholz, Switzerland
| | - Filippo-Franco Schiapparelli
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), CH-4101 Bruderholz, Switzerland
| | - Lukas B Moser
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), CH-4101 Bruderholz, Switzerland
| | - Helmut Rasch
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, CH-4101 Bruderholz, Switzerland
| | | | - Michael T Hirschmann
- Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), CH-4101 Bruderholz, Switzerland.,University of Basel, Basel, Switzerland
| |
Collapse
|
23
|
Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics. Eur J Nucl Med Mol Imaging 2019; 46:1009-1018. [PMID: 30600341 DOI: 10.1007/s00259-018-4244-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 12/17/2018] [Indexed: 12/11/2022]
Abstract
PURPOSE To compare bloodpool SPECT with planar imaging in bone SPECT/CT of painful total knee arthroplasty (TKA) with respect to inter-rater agreement, confidence, prosthesis outcome, and biomechanical functioning. METHODS Retrospective study of bloodpool SPECT and planar control images. Four raters used the validated Bruderholz scheme and a 5-point scale to grade uptake. Inter-rater agreement and overall confidence scores were calculated. Variable cluster analysis was performed to identify patterns of uptake, and associations between patterns and prosthesis outcome and biomechanical functioning were examined. RESULTS In all, 55 knees in 43 patients were analyzed (median follow-up 17 months; revision rate 21.8%). SPECT significantly improved inter-rater agreement in 24% of regions (all P < 0.05) and overall confidence by 20% (P < 0.001). Regional uptake cluster analysis showed improved antero-posterior separation with SPECT, and distinct patterns associated with prosthesis survival in lateral femoral (P = 0.041) and medial tibial (P < 0.001) regions. The prognostic value of SPECT outperformed planar imaging for tibial (P < 0.001), patellar (P = 0.009), and synovial (P = 0.040) assessment. Internal femoral malrotation resulted in increased uptake in posteromedial (P = 0.042) and anterolateral (P = 0.016) femoral, and lateral patellar (P = 0.011) regions. Internal tibial malrotation increased uptake in posterolateral (P = 0.026) and posteromedial tibial (P = 0.005), and medial patellar regions (P = 0.004). Bloodpool SPECT improved the prognostic value of late-phase SPECT/CT for the assessment of the medial tibial region. CONCLUSIONS Bloodpool SPECT outperforms planar assessment of painful TKAs and the identification of distinct uptake patterns make it a potentially clinically relevant biomarker of prosthesis survival and biomechanical functioning.
Collapse
|