1
|
Chen X, Zhou B, Guo X, Xie H, Liu Q, Duncan JS, Sinusas AJ, Liu C. DuDoCFNet: Dual-Domain Coarse-to-Fine Progressive Network for Simultaneous Denoising, Limited-View Reconstruction, and Attenuation Correction of Cardiac SPECT. IEEE TRANSACTIONS ON MEDICAL IMAGING 2024; 43:3110-3125. [PMID: 38578853 DOI: 10.1109/tmi.2024.3385650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/07/2024]
Abstract
Single-Photon Emission Computed Tomography (SPECT) is widely applied for the diagnosis of coronary artery diseases. Low-dose (LD) SPECT aims to minimize radiation exposure but leads to increased image noise. Limited-view (LV) SPECT, such as the latest GE MyoSPECT ES system, enables accelerated scanning and reduces hardware expenses but degrades reconstruction accuracy. Additionally, Computed Tomography (CT) is commonly used to derive attenuation maps ( μ -maps) for attenuation correction (AC) of cardiac SPECT, but it will introduce additional radiation exposure and SPECT-CT misalignments. Although various methods have been developed to solely focus on LD denoising, LV reconstruction, or CT-free AC in SPECT, the solution for simultaneously addressing these tasks remains challenging and under-explored. Furthermore, it is essential to explore the potential of fusing cross-domain and cross-modality information across these interrelated tasks to further enhance the accuracy of each task. Thus, we propose a Dual-Domain Coarse-to-Fine Progressive Network (DuDoCFNet), a multi-task learning method for simultaneous LD denoising, LV reconstruction, and CT-free μ -map generation of cardiac SPECT. Paired dual-domain networks in DuDoCFNet are cascaded using a multi-layer fusion mechanism for cross-domain and cross-modality feature fusion. Two-stage progressive learning strategies are applied in both projection and image domains to achieve coarse-to-fine estimations of SPECT projections and CT-derived μ -maps. Our experiments demonstrate DuDoCFNet's superior accuracy in estimating projections, generating μ -maps, and AC reconstructions compared to existing single- or multi-task learning methods, under various iterations and LD levels. The source code of this work is available at https://github.com/XiongchaoChen/DuDoCFNet-MultiTask.
Collapse
|
2
|
Kawakubo M, Nagao M, Yamamoto A, Kaimoto Y, Nakao R, Kawasaki H, Iwaguchi T, Inoue A, Kaneko K, Sakai A, Sakai S. Gated SPECT-Derived Myocardial Strain Estimated From Deep-Learning Image Translation Validated From N-13 Ammonia PET. Acad Radiol 2024:S1076-6332(24)00433-1. [PMID: 39095261 DOI: 10.1016/j.acra.2024.06.047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 06/24/2024] [Accepted: 06/27/2024] [Indexed: 08/04/2024]
Abstract
RATIONALE AND OBJECTIVES This study investigated the use of deep learning-generated virtual positron emission tomography (PET)-like gated single-photon emission tomography (SPECTVP) for assessing myocardial strain, overcoming limitations of conventional SPECT. MATERIALS AND METHODS SPECT-to-PET translation models for short-axis, horizontal, and vertical long-axis planes were trained using image pairs from the same patients in stress (720 image pairs from 18 patients) and resting states (920 image pairs from 23 patients). Patients without ejection-fraction changes during SPECT and PET were selected for training. We independently analyzed circumferential strains from short-axis-gated SPECT, PET, and model-generated SPECTVP images using a feature-tracking algorithm. Longitudinal strains were similarly measured from horizontal and vertical long-axis images. Intraclass correlation coefficients (ICCs) were calculated with two-way random single-measure SPECT and SPECTVP (PET). ICCs (95% confidence intervals) were defined as excellent (≥0.75), good (0.60-0.74), moderate (0.40-0.59), or poor (≤0.39). RESULTS Moderate ICCs were observed for SPECT-derived stressed circumferential strains (0.56 [0.41-0.69]). Excellent ICCs were observed for SPECTVP-derived stressed circumferential strains (0.78 [0.68-0.85]). Excellent ICCs of stressed longitudinal strains from horizontal and vertical long axes, derived from SPECT and SPECTVP, were observed (0.83 [0.73-0.90], 0.91 [0.85-0.94]). CONCLUSION Deep-learning SPECT-to-PET transformation improves circumferential strain measurement accuracy using standard-gated SPECT. Furthermore, the possibility of applying longitudinal strain measurements via both PET and SPECTVP was demonstrated. This study provides preliminary evidence that SPECTVP obtained from standard-gated SPECT with postprocessing potentially adds clinical value through PET-equivalent myocardial strain analysis without increasing the patient burden.
Collapse
Affiliation(s)
- Masateru Kawakubo
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Michinobu Nagao
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan.
| | - Atsushi Yamamoto
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Yoko Kaimoto
- Department of Radiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Risako Nakao
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Hiroshi Kawasaki
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Takafumi Iwaguchi
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Akihiro Inoue
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Koichiro Kaneko
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Shuji Sakai
- Department of Diagnostic Imaging & Nuclear Medicine, Tokyo Women's Medical University, Tokyo, Japan
| |
Collapse
|
3
|
Lim S, Park YJ, Lee SJ, An YS, Yoon JK. Clinical Feasibility of Deep Learning-Based Attenuation Correction Models for Tl-201 Myocardial Perfusion SPECT. Clin Nucl Med 2024; 49:397-403. [PMID: 38409758 DOI: 10.1097/rlu.0000000000005129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
PURPOSE We aimed to develop deep learning (DL)-based attenuation correction models for Tl-201 myocardial perfusion SPECT (MPS) images and evaluate their clinical feasibility. PATIENTS AND METHODS We conducted a retrospective study of patients with suspected or known coronary artery disease. We proposed a DL-based image-to-image translation technique to transform non-attenuation-corrected images into CT-based attenuation-corrected (CT AC ) images. The model was trained using a modified U-Net with structural similarity index (SSIM) loss and mean squared error (MSE) loss and compared with other models. Segment-wise analysis using a polar map and visual assessment for the generated attenuation-corrected (GEN AC ) images were also performed to evaluate clinical feasibility. RESULTS This study comprised 657 men and 328 women (age, 65 ± 11 years). Among the various models, the modified U-Net achieved the highest performance with an average mean absolute error of 0.003, an SSIM of 0.990, and a peak signal-to-noise ratio of 33.658. The performance of the model was not different between the stress and rest datasets. In the segment-wise analysis, the myocardial perfusion of the inferior wall was significantly higher in GEN AC images than in the non-attenuation-corrected images in both the rest and stress test sets ( P < 0.05). In the visual assessment of patients with diaphragmatic attenuation, scores of 4 (similar to CT AC images) or 5 (indistinguishable from CT AC images) were assigned to most GEN AC images (65/68). CONCLUSIONS Our clinically feasible DL-based attenuation correction models can replace the CT-based method in Tl-201 MPS, and it would be useful in case SPECT/CT is unavailable for MPS.
Collapse
Affiliation(s)
- Sungjoo Lim
- From the Department of Biomedical Systems Informatics, Yonsei University, Seoul
| | - Yong-Jin Park
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Su Jin Lee
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Young-Sil An
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| | - Joon-Kee Yoon
- Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine, Suwon, South Korea
| |
Collapse
|
4
|
Kawakubo M, Nagao M, Kaimoto Y, Nakao R, Yamamoto A, Kawasaki H, Iwaguchi T, Matsuo Y, Kaneko K, Sakai A, Sakai S. Deep learning approach using SPECT-to-PET translation for attenuation correction in CT-less myocardial perfusion SPECT imaging. Ann Nucl Med 2024; 38:199-209. [PMID: 38151588 PMCID: PMC10884131 DOI: 10.1007/s12149-023-01889-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Accepted: 11/23/2023] [Indexed: 12/29/2023]
Abstract
OBJECTIVE Deep learning approaches have attracted attention for improving the scoring accuracy in computed tomography-less single photon emission computed tomography (SPECT). In this study, we proposed a novel deep learning approach referring to positron emission tomography (PET). The aims of this study were to analyze the agreement of representative voxel values and perfusion scores of SPECT-to-PET translation model-generated SPECT (SPECTSPT) against PET in 17 segments according to the American Heart Association (AHA). METHODS This retrospective study evaluated the patient-to-patient stress, resting SPECT, and PET datasets of 71 patients. The SPECTSPT generation model was trained (stress: 979 image pairs, rest: 987 image pairs) and validated (stress: 421 image pairs, rest: 425 image pairs) using 31 cases of SPECT and PET image pairs using an image-to-image translation network. Forty of 71 cases of left ventricular base-to-apex short-axis images were translated to SPECTSPT in the stress and resting state (stress: 1830 images, rest: 1856 images). Representative voxel values of SPECT and SPECTSPT in the 17 AHA segments against PET were compared. The stress, resting, and difference scores of 40 cases of SPECT and SPECTSPT were also compared in each of the 17 segments. RESULTS For AHA 17-segment-wise analysis, stressed SPECT but not SPECTSPT voxel values showed significant error from PET at basal anterior regions (segments #1, #6), and at mid inferoseptal regions (segments #8, #9, and #10). SPECT, but not SPECTSPT, voxel values at resting state showed significant error at basal anterior regions (segments #1, #2, and #6), and at mid inferior regions (segments #8, #9, and #11). Significant SPECT overscoring was observed against PET in basal-to-apical inferior regions (segments #4, #10, and #15) during stress. No significant overscoring was observed in SPECTSPT at stress, and only moderate over and underscoring in the basal inferior region (segment #4) was found in the resting and difference states. CONCLUSIONS Our PET-supervised deep learning model is a new approach to correct well-known inferior wall attenuation in SPECT myocardial perfusion imaging. As standalone SPECT systems are used worldwide, the SPECTSPT generation model may be applied as a low-cost and practical clinical tool that provides powerful auxiliary information for the diagnosis of myocardial blood flow.
Collapse
Affiliation(s)
- Masateru Kawakubo
- Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, Fukuoka, Japan
| | - Michinobu Nagao
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan.
| | - Yoko Kaimoto
- Department of Radiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Risako Nakao
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Atsushi Yamamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Hiroshi Kawasaki
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Takafumi Iwaguchi
- Department of Advanced Information Technology, Faculty of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
| | - Yuka Matsuo
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| | - Koichiro Kaneko
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| | - Akiko Sakai
- Department of Cardiology, Tokyo Women's Medical University, Tokyo, Japan
| | - Shuji Sakai
- Department of Diagnostic Imaging and Nuclear Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-Ku, Tokyo, 162-8666, Japan
| |
Collapse
|
5
|
Case JA, Courter SA, McGhie AI, Patel KK, Sperry BW, Moloney E, Case KO, Burgett EV, Bateman TM. Accurate and efficient rapid acquisition early post-injection stress-first CZT SPECT myocardial perfusion imaging with tetrofosmin and attenuation correction. J Nucl Cardiol 2023; 30:2644-2654. [PMID: 37464251 DOI: 10.1007/s12350-023-03336-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 06/01/2023] [Indexed: 07/20/2023]
Abstract
INTRODUCTION Myocardial perfusion imaging (MPI) protocols have not changed significantly despite advances in instrumentation and software. We compared an early post-injection, stress-first SPECT protocol to standard delayed imaging. METHODS 95 patients referred for SPECT MPI were imaged upright and supine on a Spectrum Dynamics D-SPECT CZT system with CT attenuation correction. Patients received injection of 99mTc tetrofosmin at peak of regadenoson stress and were imaged. Early post-stress (mean 17 ± 2 minutes) and Standard 1-h delay (mean 61 ± 13 min). Three blinded readers evaluated images for overall interpretation, perceived need for rest imaging, image quality, and reader confidence. Laboratory efficiency was also evaluated. RESULTS Blinded readers had the same response for the need for rest in 77.9% of studies. Studies also had the same interpretation in 89.5% of studies. Reader confidence was high (86.0% (Early) and 90.3% (Standard p = 0.52. Image quality was good or excellent in 87.4% Early vs 96.8% Standard (p = 0.09). Time between patient check-in and end of stress imaging was 104 ± (Standard) to 60 ± 18 minutes (Early) (p < 0.001). CONCLUSION Early post-injection stress-only imaging using CZT SPECT/CT appears promising with Tc-99m tetrofosmin with similar image quality, reader confidence, diagnosis, and need for a rest scan.
Collapse
Affiliation(s)
- James A Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA.
| | | | - AIain McGhie
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Krishna K Patel
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
- Icahn School of Medicine at Mount Sinai Medical Center, New York, New York, USA
| | - Brett W Sperry
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Erin Moloney
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Katrina O Case
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Boston University, Boston, MA, USA
| | - Eric V Burgett
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| | - Timothy M Bateman
- Cardiovascular Imaging Technologies, Kansas City, MO, USA
- Mid America Heart Institute and the University of Missouri-Kansas City School of Medicine, Kansas City, MO, USA
| |
Collapse
|
6
|
Li J, Yang G, Zhang L. Artificial Intelligence Empowered Nuclear Medicine and Molecular Imaging in Cardiology: A State-of-the-Art Review. PHENOMICS (CHAM, SWITZERLAND) 2023; 3:586-596. [PMID: 38223683 PMCID: PMC10781930 DOI: 10.1007/s43657-023-00137-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 10/13/2023] [Accepted: 10/16/2023] [Indexed: 01/16/2024]
Abstract
Nuclear medicine and molecular imaging plays a significant role in the detection and management of cardiovascular disease (CVD). With recent advancements in computer power and the availability of digital archives, artificial intelligence (AI) is rapidly gaining traction in the field of medical imaging, including nuclear medicine and molecular imaging. However, the complex and time-consuming workflow and interpretation involved in nuclear medicine and molecular imaging, limit their extensive utilization in clinical practice. To address this challenge, AI has emerged as a fundamental tool for enhancing the role of nuclear medicine and molecular imaging. It has shown promising applications in various crucial aspects of nuclear cardiology, such as optimizing imaging protocols, facilitating data processing, aiding in CVD diagnosis, risk classification and prognosis. In this review paper, we will introduce the key concepts of AI and provide an overview of its current progress in the field of nuclear cardiology. In addition, we will discuss future perspectives for AI in this domain.
Collapse
Affiliation(s)
- Junhao Li
- Department of Nuclear Medicine, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| | - Guifen Yang
- Department of Nuclear Medicine, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| | - Longjiang Zhang
- Department of Radiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, 305 Zhongshan East Road, Xuanwu District, Nanjing, 210002 Jiangsu China
| |
Collapse
|
7
|
Wehbe RM, Katsaggelos AK, Hammond KJ, Hong H, Ahmad FS, Ouyang D, Shah SJ, McCarthy PM, Thomas JD. Deep Learning for Cardiovascular Imaging: A Review. JAMA Cardiol 2023; 8:1089-1098. [PMID: 37728933 DOI: 10.1001/jamacardio.2023.3142] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Importance Artificial intelligence (AI), driven by advances in deep learning (DL), has the potential to reshape the field of cardiovascular imaging (CVI). While DL for CVI is still in its infancy, research is accelerating to aid in the acquisition, processing, and/or interpretation of CVI across various modalities, with several commercial products already in clinical use. It is imperative that cardiovascular imagers are familiar with DL systems, including a basic understanding of how they work, their relative strengths compared with other automated systems, and possible pitfalls in their implementation. The goal of this article is to review the methodology and application of DL to CVI in a simple, digestible fashion toward demystifying this emerging technology. Observations At its core, DL is simply the application of a series of tunable mathematical operations that translate input data into a desired output. Based on artificial neural networks that are inspired by the human nervous system, there are several types of DL architectures suited to different tasks; convolutional neural networks are particularly adept at extracting valuable information from CVI data. We survey some of the notable applications of DL to tasks across the spectrum of CVI modalities. We also discuss challenges in the development and implementation of DL systems, including avoiding overfitting, preventing systematic bias, improving explainability, and fostering a human-machine partnership. Finally, we conclude with a vision of the future of DL for CVI. Conclusions and Relevance Deep learning has the potential to meaningfully affect the field of CVI. Rather than a threat, DL could be seen as a partner to cardiovascular imagers in reducing technical burden and improving efficiency and quality of care. High-quality prospective evidence is still needed to demonstrate how the benefits of DL CVI systems may outweigh the risks.
Collapse
Affiliation(s)
- Ramsey M Wehbe
- Division of Cardiology, Department of Medicine & Biomedical Informatics Center, Medical University of South Carolina, Charleston
- Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Aggelos K Katsaggelos
- Department of Computer and Electrical Engineering, Northwestern University, Evanston, Illinois
| | - Kristian J Hammond
- Department of Computer Science, Northwestern University, Evanston, Illinois
| | - Ha Hong
- Medtronic, Minneapolis, Minnesota
| | - Faraz S Ahmad
- Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
- Center for Health Information Partnerships, Institute for Public Health and Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
- Center for Artificial Intelligence, Northwestern Medicine Bluhm Cardiovascular Institute, Chicago, Illinois
| | - David Ouyang
- Division of Cardiology, Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California
| | - Sanjiv J Shah
- Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
- Center for Artificial Intelligence, Northwestern Medicine Bluhm Cardiovascular Institute, Chicago, Illinois
| | - Patrick M McCarthy
- Division of Cardiac Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois
- Center for Artificial Intelligence, Northwestern Medicine Bluhm Cardiovascular Institute, Chicago, Illinois
| | - James D Thomas
- Division of Cardiology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
- Center for Artificial Intelligence, Northwestern Medicine Bluhm Cardiovascular Institute, Chicago, Illinois
| |
Collapse
|
8
|
Ibrahim J, Soman P. The past, present, and future of attenuation correction for myocardial perfusion imaging. J Nucl Cardiol 2023; 30:1794-1796. [PMID: 37311912 DOI: 10.1007/s12350-023-03311-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 06/15/2023]
Affiliation(s)
- Joseph Ibrahim
- Division of Cardiology & the Heart and Vascular Institute, University of Pittsburgh Medical Center, A-429 Scaife Hall, 200 Lothrop Street, Pittsburgh, PA, 15213, USA
| | - Prem Soman
- Division of Cardiology & the Heart and Vascular Institute, University of Pittsburgh Medical Center, A-429 Scaife Hall, 200 Lothrop Street, Pittsburgh, PA, 15213, USA.
| |
Collapse
|
9
|
Chen X, Liu C. Deep-learning-based methods of attenuation correction for SPECT and PET. J Nucl Cardiol 2023; 30:1859-1878. [PMID: 35680755 DOI: 10.1007/s12350-022-03007-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Accepted: 05/02/2022] [Indexed: 10/18/2022]
Abstract
Attenuation correction (AC) is essential for quantitative analysis and clinical diagnosis of single-photon emission computed tomography (SPECT) and positron emission tomography (PET). In clinical practice, computed tomography (CT) is utilized to generate attenuation maps (μ-maps) for AC of hybrid SPECT/CT and PET/CT scanners. However, CT-based AC methods frequently produce artifacts due to CT artifacts and misregistration of SPECT-CT and PET-CT scans. Segmentation-based AC methods using magnetic resonance imaging (MRI) for PET/MRI scanners are inaccurate and complicated since MRI does not contain direct information of photon attenuation. Computational AC methods for SPECT and PET estimate attenuation coefficients directly from raw emission data, but suffer from low accuracy, cross-talk artifacts, high computational complexity, and high noise level. The recently evolving deep-learning-based methods have shown promising results in AC of SPECT and PET, which can be generally divided into two categories: indirect and direct strategies. Indirect AC strategies apply neural networks to transform emission, transmission, or MR images into synthetic μ-maps or CT images which are then incorporated into AC reconstruction. Direct AC strategies skip the intermediate steps of generating μ-maps or CT images and predict AC SPECT or PET images from non-attenuation-correction (NAC) SPECT or PET images directly. These deep-learning-based AC methods show comparable and even superior performance to non-deep-learning methods. In this article, we first discussed the principles and limitations of non-deep-learning AC methods, and then reviewed the status and prospects of deep-learning-based methods for AC of SPECT and PET.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520, USA.
| |
Collapse
|
10
|
Sun H, Wang F, Yang Y, Hong X, Xu W, Wang S, Mok GSP, Lu L. Transfer learning-based attenuation correction for static and dynamic cardiac PET using a generative adversarial network. Eur J Nucl Med Mol Imaging 2023; 50:3630-3646. [PMID: 37474736 DOI: 10.1007/s00259-023-06343-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 07/12/2023] [Indexed: 07/22/2023]
Abstract
PURPOSE The goal of this work is to demonstrate the feasibility of directly generating attenuation-corrected PET images from non-attenuation-corrected (NAC) PET images for both rest and stress-state static or dynamic [13N]ammonia MP PET based on a generative adversarial network. METHODS We recruited 60 subjects for rest-only scans and 14 subjects for rest-stress scans, all of whom underwent [13N]ammonia cardiac PET/CT examinations to acquire static and dynamic frames with both 3D NAC and CT-based AC (CTAC) PET images. We developed a 3D pix2pix deep learning AC (DLAC) framework via a U-net + ResNet-based generator and a convolutional neural network-based discriminator. Paired static or dynamic NAC and CTAC PET images from 60 rest-only subjects were used as network inputs and labels for static (S-DLAC) and dynamic (D-DLAC) training, respectively. The pre-trained S-DLAC network was then fine-tuned by paired dynamic NAC and CTAC PET frames of 60 rest-only subjects to derive an improved D-DLAC-FT for dynamic PET images. The 14 rest-stress subjects were used as an internal testing dataset and separately tested on different network models without training. The proposed methods were evaluated using visual quality and quantitative metrics. RESULTS The proposed S-DLAC, D-DLAC, and D-DLAC-FT methods were consistent with clinical CTAC in terms of various images and quantitative metrics. The S-DLAC (slope = 0.9423, R2 = 0.947) showed a higher correlation with the reference static CTAC as compared to static NAC (slope = 0.0992, R2 = 0.654). D-DLAC-FT yielded lower myocardial blood flow (MBF) errors in the whole left ventricular myocardium than D-DLAC, but with no significant difference, both for the 60 rest-state subjects (6.63 ± 5.05% vs. 7.00 ± 6.84%, p = 0.7593) and the 14 stress-state subjects (1.97 ± 2.28% vs. 3.21 ± 3.89%, p = 0.8595). CONCLUSION The proposed S-DLAC, D-DLAC, and D-DLAC-FT methods achieve comparable performance with clinical CTAC. Transfer learning shows promising potential for dynamic MP PET.
Collapse
Affiliation(s)
- Hao Sun
- School of Biomedical Engineering, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
| | - Fanghu Wang
- PET Center, Department of Nuclear Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
| | - Yuling Yang
- School of Biomedical Engineering, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
| | - Xiaotong Hong
- School of Biomedical Engineering, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China
| | - Weiping Xu
- PET Center, Department of Nuclear Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China
| | - Shuxia Wang
- PET Center, Department of Nuclear Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
| | - Lijun Lu
- School of Biomedical Engineering, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China.
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China.
- Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, 1023 Shatai Road, Guangzhou, 510515, China.
- Pazhou Lab, Guangzhou, 510330, China.
| |
Collapse
|
11
|
Huxohl T, Patel G, Zabel R, Burchert W. Deep learning approximation of attenuation maps for myocardial perfusion SPECT with an IQ[Formula: see text]SPECT collimator. EJNMMI Phys 2023; 10:49. [PMID: 37639082 PMCID: PMC10462587 DOI: 10.1186/s40658-023-00568-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 08/07/2023] [Indexed: 08/29/2023] Open
Abstract
BACKGROUND The use of CT images for attenuation correction of myocardial perfusion imaging with single photon emission computer tomography (SPECT) increases diagnostic confidence. However, acquiring a CT image registered to a SPECT image is often not possible because most scanners are SPECT-only. It is possible to approximate attenuation maps using deep learning, but this has not yet been shown to work for a SPECT scanner with an IQ[Formula: see text]SPECT collimator. This study investigates whether it is possible to approximate attenuation maps from non-attenuation-corrected (nAC) reconstructions acquired with a SPECT scanner equipped with an IQ[Formula: see text]SPECT collimator. METHODS Attenuation maps and reconstructions were acquired retrospectively for 150 studies. A U-Net was trained to predict attenuation maps from nAC reconstructions using the conditional generative adversarial network framework. Predicted attenuation maps are compared to real attenuation maps using the normalized mean absolute error (NMAE). Attenuation-corrected reconstructions were computed, and the resulting polar maps were compared by pixel and by average perfusion per segment using the absolute percent error (APE). The training and evaluation code is available at https://gitlab.ub.uni-bielefeld.de/thuxohl/mu-map . RESULTS Predicted attenuation maps are similar to real attenuation maps, achieving an NMAE of 0.020±0.007. The same is true for polar maps generated from reconstructions with predicted attenuation maps compared to CT-based attenuation maps. Their pixel-wise absolute distance is 3.095±3.199, and the segment-wise APE is 1.155±0.769. CONCLUSIONS It is feasible to approximate attenuation maps from nAC reconstructions acquired by a scanner with an IQ[Formula: see text]SPECT collimator using deep learning.
Collapse
Affiliation(s)
- Tamino Huxohl
- Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital of the Ruhr University Bochum, Bad Oeynhausen, Germany
| | - Gopesh Patel
- Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital of the Ruhr University Bochum, Bad Oeynhausen, Germany
| | - Reinhard Zabel
- Institute of Nuclear Medicine, Hospital Lippe, Lippe, Germany
| | - Wolfgang Burchert
- Institute of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Center North Rhine-Westphalia, University Hospital of the Ruhr University Bochum, Bad Oeynhausen, Germany
| |
Collapse
|
12
|
Du Y, Jiang H, Lin CN, Peng Z, Sun J, Chiu PY, Hung GU, Mok GSP. Generative adversarial network-based attenuation correction for 99mTc-TRODAT-1 brain SPECT. Front Med (Lausanne) 2023; 10:1171118. [PMID: 37654658 PMCID: PMC10465694 DOI: 10.3389/fmed.2023.1171118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Accepted: 07/17/2023] [Indexed: 09/02/2023] Open
Abstract
Background Attenuation correction (AC) is an important correction method to improve the quantification accuracy of dopamine transporter (DAT) single photon emission computed tomography (SPECT). Chang's method was developed for AC (Chang-AC) when CT-based AC was not available, assuming uniform attenuation coefficients inside the body contour. This study aims to evaluate Chang-AC and different deep learning (DL)-based AC approaches on 99mTc-TRODAT-1 brain SPECT using clinical patient data on two different scanners. Methods Two hundred and sixty patients who underwent 99mTc-TRODAT-1 SPECT/CT scans from two different scanners (scanner A and scanner B) were retrospectively recruited. The ordered-subset expectation-maximization (OS-EM) method reconstructed 120 projections with dual-energy scatter correction, with or without CT-AC. We implemented a 3D conditional generative adversarial network (cGAN) for the indirect deep learning-based attenuation correction (DL-ACμ) and direct deep learning-based attenuation correction (DL-AC) methods, estimating attenuation maps (μ-maps) and attenuation-corrected SPECT images from non-attenuation-corrected (NAC) SPECT, respectively. We further applied cross-scanner training (cross-scanner indirect deep learning-based attenuation correction [cull-ACμ] and cross-scanner direct deep learning-based attenuation correction [call-AC]) and merged the datasets from two scanners for ensemble training (ensemble indirect deep learning-based attenuation correction [eDL-ACμ] and ensemble direct deep learning-based attenuation correction [eDL-AC]). The estimated μ-maps from (c/e)DL-ACμ were then used in reconstruction for AC purposes. Chang's method was also implemented for comparison. Normalized mean square error (NMSE), structural similarity index (SSIM), specific uptake ratio (SUR), and asymmetry index (%ASI) of the striatum were calculated for different AC methods. Results The NMSE for Chang's method, DL-ACμ, DL-AC, cDL-ACμ, cDL-AC, eDL-ACμ, and eDL-AC is 0.0406 ± 0.0445, 0.0059 ± 0.0035, 0.0099 ± 0.0066, 0.0253 ± 0.0102, 0.0369 ± 0.0124, 0.0098 ± 0.0035, and 0.0162 ± 0.0118 for scanner A and 0.0579 ± 0.0146, 0.0055 ± 0.0034, 0.0063 ± 0.0028, 0.0235 ± 0.0085, 0.0349 ± 0.0086, 0.0115 ± 0.0062, and 0.0117 ± 0.0038 for scanner B, respectively. The SUR and %ASI results for DL-ACμ are closer to CT-AC, Followed by DL-AC, eDL-ACμ, cDL-ACμ, cDL-AC, eDL-AC, Chang's method, and NAC. Conclusion All DL-based AC methods are superior to Chang-AC. DL-ACμ is superior to DL-AC. Scanner-specific training is superior to cross-scanner and ensemble training. DL-based AC methods are feasible and robust for 99mTc-TRODAT-1 brain SPECT.
Collapse
Affiliation(s)
- Yu Du
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| | - Han Jiang
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Ching-Ni Lin
- Department of Nuclear Medicine, Show Chwan Memorial Hospital, Lukong Town, Changhua County, Taiwan
| | - Zhengyu Peng
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Pai-Yi Chiu
- Department of Neurology, Show Chwan Memorial Hospital, Lukong Town, Changhua County, Taiwan
| | - Guang-Uei Hung
- Department of Nuclear Medicine, Chang Bing Show Chwan Memorial Hospital, Lukong Town, Changhua County, Taiwan
| | - Greta S. P. Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| |
Collapse
|
13
|
Prieto Canalejo MA, Palau San Pedro A, Geronazzo R, Minsky DM, Juárez-Orozco LE, Namías M. Synthetic Attenuation Correction Maps for SPECT Imaging Using Deep Learning: A Study on Myocardial Perfusion Imaging. Diagnostics (Basel) 2023; 13:2214. [PMID: 37443608 DOI: 10.3390/diagnostics13132214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 06/24/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023] Open
Abstract
(1) Background: The CT-based attenuation correction of SPECT images is essential for obtaining accurate quantitative images in cardiovascular imaging. However, there are still many SPECT cameras without associated CT scanners throughout the world, especially in developing countries. Performing additional CT scans implies troublesome planning logistics and larger radiation doses for patients, making it a suboptimal solution. Deep learning (DL) offers a revolutionary way to generate complementary images for individual patients at a large scale. Hence, we aimed to generate linear attenuation coefficient maps from SPECT emission images reconstructed without attenuation correction using deep learning. (2) Methods: A total of 384 SPECT myocardial perfusion studies that used 99mTc-sestamibi were included. A DL model based on a 2D U-Net architecture was trained using information from 312 patients. The quality of the generated synthetic attenuation correction maps (ACMs) and reconstructed emission values were evaluated using three metrics and compared to standard-of-care data using Bland-Altman plots. Finally, a quantitative evaluation of myocardial uptake was performed, followed by a semi-quantitative evaluation of myocardial perfusion. (3) Results: In a test set of 66 test patients, the ACM quality metrics were MSSIM = 0.97 ± 0.001 and NMAE = 3.08 ± 1.26 (%), and the reconstructed emission quality metrics were MSSIM = 0.99 ± 0.003 and NMAE = 0.23 ± 0.13 (%). The 95% limits of agreement (LoAs) at the voxel level for reconstructed SPECT images were: [-9.04; 9.00]%, and for the segment level, they were [-11; 10]%. The 95% LoAs for the Summed Stress Score values between the images reconstructed were [-2.8, 3.0]. When global perfusion scores were assessed, only 2 out of 66 patients showed changes in perfusion categories. (4) Conclusion: Deep learning can generate accurate attenuation correction maps from non-attenuation-corrected cardiac SPECT images. These high-quality attenuation maps are suitable for attenuation correction in myocardial perfusion SPECT imaging and could obviate the need for additional imaging in standalone SPECT scanners.
Collapse
Affiliation(s)
| | | | - Ricardo Geronazzo
- Fundación Centro Diagnóstico Nuclear (FCDN), Buenos Aires C1417CVE, Argentina
| | - Daniel Mauricio Minsky
- Centro Atómico Constituyentes, Comisión Nacional de Energía Atómica, San Martín B1650LWP, Argentina
| | | | - Mauro Namías
- Fundación Centro Diagnóstico Nuclear (FCDN), Buenos Aires C1417CVE, Argentina
| |
Collapse
|
14
|
Du Y, Shang J, Sun J, Wang L, Liu YH, Xu H, Mok GSP. Deep-learning-based estimation of attenuation map improves attenuation correction performance over direct attenuation estimation for myocardial perfusion SPECT. J Nucl Cardiol 2023; 30:1022-1037. [PMID: 36097242 DOI: 10.1007/s12350-022-03092-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 07/31/2022] [Indexed: 11/28/2022]
Abstract
BACKGROUND Deep learning (DL)-based attenuation correction (AC) is promising to improve myocardial perfusion (MP) SPECT. We aimed to optimize and compare the DL-based direct and indirect AC methods, with and without SPECT and CT mismatch. METHODS One hundred patients with different 99mTc-sestamibi activity distributions and anatomical variations were simulated by a population of XCAT phantoms. Additionally, 34 patients 99mTc-sestamibi stress/rest SPECT/CT scans were retrospectively recruited. Projections were reconstructed by OS-EM method with or without AC. Mismatch between SPECT and CT images was modeled. A 3D conditional generative adversarial network (cGAN) was optimized for two DL-based AC methods: (i) indirect approach, i.e., non-attenuation corrected (NAC) SPECT paired with the corresponding attenuation map for training. The projections were reconstructed with the DL-generated attenuation map for AC; (ii) direct approach, i.e., NAC SPECT paired with the corresponding AC SPECT for training to perform direct AC. RESULTS Mismatch between SPECT and CT degraded DL-based AC performance. The indirect approach is superior to direct approach for various physical and clinical indices, even with mismatch modeled. CONCLUSION DL-based estimation of attenuation map for AC is superior and more robust to direct generation of AC SPECT.
Collapse
Affiliation(s)
- Yu Du
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| | - Jingjie Shang
- Department of Nuclear Medicine and PET/CT-MRI Centre, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, China
| | - Jingzhang Sun
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China
| | - Lu Wang
- Department of Nuclear Medicine and PET/CT-MRI Centre, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, China
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
| | - Hao Xu
- Department of Nuclear Medicine and PET/CT-MRI Centre, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong, China
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Taipa, Macau SAR, China.
- Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China.
| |
Collapse
|
15
|
Xing H, Wang T, Jin X, Tian J, Ba J, Jing H, Li F. Direct attenuation correction for 99mTc-3PRGD 2 chest SPECT lung cancer images using deep learning. Front Oncol 2023; 13:1165664. [PMID: 37251952 PMCID: PMC10218122 DOI: 10.3389/fonc.2023.1165664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 04/26/2023] [Indexed: 05/31/2023] Open
Abstract
Introduction The attenuation correction technique of single photon emission computed tomography (SPECT) images is essential for early diagnosis, therapeutic evaluation, and pharmacokinetic studies of lung cancer. 99mTc-3PRGD2 is a novel radiotracer for the early diagnosis and evaluation of treatment effects of lung cancer. This study preliminary discusses the deep learning method to directly correct the attenuation of 99mTc-3PRGD2 chest SPECT images. Methods Retrospective analysis was performed on 53 patients with pathological diagnosis of lung cancer who received 99mTc-3PRGD2 chest SPECT/CT. All patients' SPECT/CT images were reconstructed with CT attenuation correction (CT-AC) and without attenuation correction (NAC). The CT-AC image was used as the reference standard (Ground Truth) to train the attenuation correction (DL-AC) SPECT image model using deep learning. A total of 48 of 53 cases were divided randomly into the training set, the remaining 5 were divided into the testing set. Using 3D Unet neural network, the mean square error loss function (MSELoss) of 0.0001 was selected. A testing set is used to evaluate the model quality, using the SPECT image quality evaluation and quantitative analysis of lung lesions tumor-to-background (T/B). Results SPECT imaging quality metrics between DL-AC and CT-AC including mean absolute error (MAE), mean-square error (MSE), peak signal-to-noise ratio (PSNR), structural similarity (SSIM), normalized root mean square error (NRMSE), and normalized Mutual Information (NMI) of the testing set are 2.62 ± 0.45, 58.5 ± 14.85, 45.67 ± 2.80, 0.82 ± 0.02, 0.07 ± 0.04, and 1.58 ± 0.06, respectively. These results indicate PSNR > 42, SSIM > 0.8, and NRMSE < 0.11. Lung lesions T/B (maximum) of CT-AC and DL-AC groups are 4.36 ± 3.52 and 4.33 ± 3.09, respectively (p = 0.81). There are no significant differences between two attenuation correction methods. Conclusion Our preliminary research results indicate that using the DL-AC method to directly correct 99mTc-3PRGD2 chest SPECT images is highly accurate and feasible for SPECT without configuration with CT or treatment effect evaluation using multiple SPECT/CT scans.
Collapse
Affiliation(s)
| | | | | | | | - Jiantao Ba
- *Correspondence: Jiantao Ba, ; Hongli Jing, ; Fang Li,
| | - Hongli Jing
- *Correspondence: Jiantao Ba, ; Hongli Jing, ; Fang Li,
| | - Fang Li
- *Correspondence: Jiantao Ba, ; Hongli Jing, ; Fang Li,
| |
Collapse
|
16
|
Yu Z, Rahman MA, Abbey CK, Siegel BA, Jha AK. Development and task-based evaluation of a scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT. ARXIV 2023:arXiv:2303.00197v2. [PMID: 36911280 PMCID: PMC10002798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 03/14/2023]
Abstract
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantages of increased radiation dose, increased scanner cost, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.
Collapse
Affiliation(s)
- Zitong Yu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
| | - Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
| | - Craig K. Abbey
- Department of Psychological & Brain Sciences, University of California Santa Barbara, Santa Barbara, USA
| | - Barry A. Siegel
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, USA
| | - Abhinav K. Jha
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, USA
| |
Collapse
|
17
|
Shanbhag AD, Miller RJH, Pieszko K, Lemley M, Kavanagh P, Feher A, Miller EJ, Sinusas AJ, Kaufmann PA, Han D, Huang C, Liang JX, Berman DS, Dey D, Slomka PJ. Deep Learning-Based Attenuation Correction Improves Diagnostic Accuracy of Cardiac SPECT. J Nucl Med 2023; 64:472-478. [PMID: 36137759 PMCID: PMC10071806 DOI: 10.2967/jnumed.122.264429] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 09/16/2022] [Accepted: 09/16/2022] [Indexed: 11/16/2022] Open
Abstract
To improve diagnostic accuracy, myocardial perfusion imaging (MPI) SPECT studies can use CT-based attenuation correction (AC). However, CT-based AC is not available for most SPECT systems in clinical use, increases radiation exposure, and is impacted by misregistration. We developed and externally validated a deep-learning model to generate simulated AC images directly from non-AC (NC) SPECT, without the need for CT. Methods: SPECT myocardial perfusion imaging was performed using 99mTc-sestamibi or 99mTc-tetrofosmin on contemporary scanners with solid-state detectors. We developed a conditional generative adversarial neural network that applies a deep learning model (DeepAC) to generate simulated AC SPECT images. The model was trained with short-axis NC and AC images performed at 1 site (n = 4,886) and was tested on patients from 2 separate external sites (n = 604). We assessed the diagnostic accuracy of the stress total perfusion deficit (TPD) obtained from NC, AC, and DeepAC images for obstructive coronary artery disease (CAD) with area under the receiver-operating-characteristic curve. We also quantified the direct count change among AC, NC, and DeepAC images on a per-voxel basis. Results: DeepAC could be obtained in less than 1 s from NC images; area under the receiver-operating-characteristic curve for obstructive CAD was higher for DeepAC TPD (0.79; 95% CI, 0.72-0.85) than for NC TPD (0.70; 95% CI, 0.63-0.78; P < 0.001) and similar to AC TPD (0.81; 95% CI, 0.75-0.87; P = 0.196). The normalcy rate in the low-likelihood-of-coronary-disease population was higher for DeepAC TPD (70.4%) and AC TPD (75.0%) than for NC TPD (54.6%, P < 0.001 for both). The positive count change (increase in counts) was significantly higher for AC versus NC (median, 9.4; interquartile range, 6.0-14.2; P < 0.001) than for AC versus DeepAC (median, 2.4; interquartile range, 1.3-4.2). Conclusion: In an independent external dataset, DeepAC provided improved diagnostic accuracy for obstructive CAD, as compared with NC images, and this accuracy was similar to that of actual AC. DeepAC simplifies the task of artifact identification for physicians, avoids misregistration artifacts, and can be performed rapidly without the need for CT hardware and additional acquisitions.
Collapse
Affiliation(s)
- Aakash D Shanbhag
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Robert J H Miller
- Department of Cardiac Sciences, University of Calgary, Calgary, Alberta, Canada
| | - Konrad Pieszko
- Department of Interventional Cardiology and Cardiac Surgery, University of Zielona Góra, Zielona Góra, Poland
| | - Mark Lemley
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Paul Kavanagh
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Attila Feher
- Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut; and
| | - Edward J Miller
- Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut; and
| | - Albert J Sinusas
- Section of Cardiovascular Medicine, Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut; and
| | - Philipp A Kaufmann
- Cardiac Imaging, Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland
| | - Donghee Han
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Cathleen Huang
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Joanna X Liang
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Daniel S Berman
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Damini Dey
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California
| | - Piotr J Slomka
- Departments of Medicine (Division of Artificial Intelligence in Medicine), Imaging, and Biomedical Sciences, Cedars-Sinai Medical Center, Los Angeles, California;
| |
Collapse
|
18
|
Yu Z, Rahman MA, Abbey CK, Siegel BA, Jha AK. Development and task-based evaluation of a scatter-window projection and deep learning-based transmission-less attenuation compensation method for myocardial perfusion SPECT. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2023; 12463:124631E. [PMID: 37274423 PMCID: PMC10238080 DOI: 10.1117/12.2654500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Attenuation compensation (AC) is beneficial for visual interpretation tasks in single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). However, traditional AC methods require the availability of a transmission scan, most often a CT scan. This approach has the disadvantage of increased radiation dose, increased scanner costs, and the possibility of inaccurate diagnosis in cases of misregistration between the SPECT and CT images. Further, many SPECT systems do not include a CT component. To address these issues, we developed a Scatter-window projection and deep Learning-based AC (SLAC) method to perform AC without a separate transmission scan. To investigate the clinical efficacy of this method, we then objectively evaluated the performance of this method on the clinical task of detecting perfusion defects on MPI in a retrospective study with anonymized clinical SPECT/CT stress MPI images. The proposed method was compared with CT-based AC (CTAC) and no-AC (NAC) methods. Our results showed that the SLAC method yielded an almost overlapping receiver operating characteristic (ROC) plot and a similar area under the ROC (AUC) to the CTAC method on this task. These results demonstrate the capability of the SLAC method for transmission-less AC in SPECT and motivate further clinical evaluation.
Collapse
Affiliation(s)
- Zitong Yu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
| | - Md Ashequr Rahman
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
| | - Craig K. Abbey
- Department of Psychological & Brain Sciences, University of California Santa Barbara, Santa Barbara, USA
| | - Barry A. Siegel
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, USA
| | - Abhinav K. Jha
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, USA
- Mallinckrodt Institute of Radiology, Washington University in St. Louis, St. Louis, USA
| |
Collapse
|
19
|
Apostolopoulos ID, Papandrianos NI, Feleki A, Moustakidis S, Papageorgiou EI. Deep learning-enhanced nuclear medicine SPECT imaging applied to cardiac studies. EJNMMI Phys 2023; 10:6. [PMID: 36705775 PMCID: PMC9883373 DOI: 10.1186/s40658-022-00522-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Accepted: 12/19/2022] [Indexed: 01/28/2023] Open
Abstract
Deep learning (DL) has a growing popularity and is a well-established method of artificial intelligence for data processing, especially for images and videos. Its applications in nuclear medicine are broad and include, among others, disease classification, image reconstruction, and image de-noising. Positron emission tomography (PET) and single-photon emission computerized tomography (SPECT) are major image acquisition technologies in nuclear medicine. Though several studies have been conducted to apply DL in many nuclear medicine domains, such as cancer detection and classification, few studies have employed such methods for cardiovascular disease applications. The present paper reviews recent DL approaches focused on cardiac SPECT imaging. Extensive research identified fifty-five related studies, which are discussed. The review distinguishes between major application domains, including cardiovascular disease diagnosis, SPECT attenuation correction, image denoising, full-count image estimation, and image reconstruction. In addition, major findings and dominant techniques employed for the mentioned task are revealed. Current limitations of DL approaches and future research directions are discussed.
Collapse
Affiliation(s)
- Ioannis D. Apostolopoulos
- grid.11047.330000 0004 0576 5395Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece ,grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Nikolaos I. Papandrianos
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Anna Feleki
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| | - Serafeim Moustakidis
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece ,AIDEAS OÜ, 10117 Tallinn, Estonia
| | - Elpiniki I. Papageorgiou
- grid.410558.d0000 0001 0035 6670Department of Energy Systems, University of Thessaly, Gaiopolis Campus, 41500 Larisa, Greece
| |
Collapse
|
20
|
Chen X, Hendrik Pretorius P, Zhou B, Liu H, Johnson K, Liu YH, King MA, Liu C. Cross-vender, cross-tracer, and cross-protocol deep transfer learning for attenuation map generation of cardiac SPECT. J Nucl Cardiol 2022; 29:3379-3391. [PMID: 35474443 DOI: 10.1007/s12350-022-02978-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 03/28/2022] [Indexed: 01/18/2023]
Abstract
It has been proved feasible to generate attenuation maps (μ-maps) from cardiac SPECT using deep learning. However, this assumed that the training and testing datasets were acquired using the same scanner, tracer, and protocol. We investigated a robust generation of CT-derived μ-maps from cardiac SPECT acquired by different scanners, tracers, and protocols from the training data. We first pre-trained a network using 120 studies injected with 99mTc-tetrofosmin acquired from a GE 850 SPECT/CT with 360-degree gantry rotation, which was then fine-tuned and tested using 80 studies injected with 99mTc-sestamibi acquired from a Philips BrightView SPECT/CT with 180-degree gantry rotation. The error between ground-truth and predicted μ-maps by transfer learning was 5.13 ± 7.02%, as compared to 8.24 ± 5.01% by direct transition without fine-tuning and 6.45 ± 5.75% by limited-sample training. The error between ground-truth and reconstructed images with predicted μ-maps by transfer learning was 1.11 ± 1.57%, as compared to 1.72 ± 1.63% by direct transition and 1.68 ± 1.21% by limited-sample training. It is feasible to apply a network pre-trained by a large amount of data from one scanner to data acquired by another scanner using different tracers and protocols, with proper transfer learning.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - P Hendrik Pretorius
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | - Karen Johnson
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University, New Haven, CT, USA
- Department of Biomedical Imaging and Radiological Sciences, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Michael A King
- Department of Radiology, University of Massachusetts Medical School, 55 Lake Avenue North, Worcester, MA, 01655, USA.
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520, USA.
| |
Collapse
|
21
|
Liu H, Wu J, Shi L, Liu Y, Miller E, Sinusas A, Liu YH, Liu C. Post-reconstruction attenuation correction for SPECT myocardium perfusion imaging facilitated by deep learning-based attenuation map generation. J Nucl Cardiol 2022; 29:2881-2892. [PMID: 34671940 DOI: 10.1007/s12350-021-02817-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 09/09/2021] [Indexed: 01/18/2023]
Abstract
BACKGROUND Attenuation correction can improve the quantitative accuracy of single-photon emission computed tomography (SPECT) images. Existing SPECT-only systems normally can only provide non-attenuation corrected (NC) images which are susceptible to attenuation artifacts. In this work, we developed a post-reconstruction attenuation correction (PRAC) approach facilitated by a deep learning-based attenuation map for myocardial perfusion SPECT imaging. METHODS In the PRAC method, new projection data were estimated via forwardly projecting the scanner-generated NC image. Then an attenuation map, generated from NC image using a pretrained deep learning (DL) convolutional neural network, was incorporated into an offline reconstruction algorithm to obtain the attenuation-corrected images from the forwardly projected projections. We evaluated the PRAC method using 30 subjects with a DL network trained with 40 subjects, using the vendor-generated AC images and CT-based attenuation maps as the ground truth. RESULTS The PRAC methods using DL-generated and CT-based attenuation maps were both highly consistent with the scanner-generated AC image. The globally normalized mean absolute errors were 1.1% ± .6% and .7% ± .4% and the localized absolute percentage errors were 8.9% ± 13.4% and 7.8% ± 11.4% in the left ventricular (LV) blood pool, respectively, and - 1.3% ± 8.0% and - 3.8% ± 4.5% in the LV myocardium for PRAC methods using DL-generated and CT-based attenuation maps, respectively. The summed stress scores after PRAC using both attenuation maps were more consistent with the ground truth than those of the NC images. CONCLUSION We developed a PRAC approach facilitated by deep learning-based attenuation maps for SPECT myocardial perfusion imaging. It may be feasible for this approach to provide AC images for SPECT-only scanner data.
Collapse
Affiliation(s)
- Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA.
- Department of Engineering Physics, Tsinghua University, Beijing, 100084, China.
- Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China.
| | - Jing Wu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA
- Center for Advanced Quantum Studies and Department of Physics, Beijing Normal University, Beijing, China
| | - Luyao Shi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Yaqiang Liu
- Department of Engineering Physics, Tsinghua University, Beijing, 100084, China
- Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing, China
| | - Edward Miller
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA
- Department of Internal Medicine (Cardiology), Yale University, New Haven, CT, USA
| | - Albert Sinusas
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Internal Medicine (Cardiology), Yale University, New Haven, CT, USA
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University, New Haven, CT, USA
- Department of Biomedical Imaging and Radiological Sciences, National Yangming Jiaotong University, Taipei, Taiwan
| | - Chi Liu
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06520, USA.
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
| |
Collapse
|
22
|
Hagio T, Murthy VL. Deep learning: Opening a third eye to myocardial perfusion imaging. J Nucl Cardiol 2022; 29:3311-3314. [PMID: 35554868 DOI: 10.1007/s12350-022-02959-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 03/09/2022] [Indexed: 01/18/2023]
Affiliation(s)
- Tomoe Hagio
- INVIA Medical Imaging Solutions, 3025 Boardwalk St, Suite 200, Ann Arbor, MI, 48108, USA.
| | - Venkatesh L Murthy
- Division of Cardiovascular Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
23
|
Chen X, Zhou B, Shi L, Liu H, Pang Y, Wang R, Miller EJ, Sinusas AJ, Liu C. CT-free attenuation correction for dedicated cardiac SPECT using a 3D dual squeeze-and-excitation residual dense network. J Nucl Cardiol 2022; 29:2235-2250. [PMID: 34085168 DOI: 10.1007/s12350-021-02672-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 05/07/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Attenuation correction (AC) using CT transmission scanning enables the accurate quantitative analysis of dedicated cardiac SPECT. However, AC is challenging for SPECT-only scanners. We developed a deep learning-based approach to generate synthetic AC images from SPECT images without AC. METHODS CT-free AC was implemented using our customized Dual Squeeze-and-Excitation Residual Dense Network (DuRDN). 172 anonymized clinical hybrid SPECT/CT stress/rest myocardial perfusion studies were used in training, validation, and testing. Additional body mass index (BMI), gender, and scatter-window information were encoded as channel-wise input to further improve the network performance. RESULTS Quantitative and qualitative analysis based on image voxels and 17-segment polar map showed the potential of our approach to generate consistent SPECT AC images. Our customized DuRDN showed superior performance to conventional network design such as U-Net. The averaged voxel-wise normalized mean square error (NMSE) between the predicted AC images by DuRDN and the ground-truth AC images was 2.01 ± 1.01%, as compared to 2.23 ± 1.20% by U-Net. CONCLUSIONS Our customized DuRDN facilitates dedicated cardiac SPECT AC without CT scanning. DuRDN can efficiently incorporate additional patient information and may achieve better performance compared to conventional U-Net.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Luyao Shi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520-8048, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | - Yulei Pang
- Department of Mathematics, Southern Connecticut State University, New Haven, CT, USA
| | - Rui Wang
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520-8048, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | - Edward J Miller
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520-8048, USA
- Department of Medicine (Cardiology), Yale University, New Haven, CT, USA
| | - Albert J Sinusas
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520-8048, USA
- Department of Medicine (Cardiology), Yale University, New Haven, CT, USA
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, PO Box 208048, New Haven, CT, 06520-8048, USA.
| |
Collapse
|
24
|
Torkaman M, Yang J, Shi L, Wang R, Miller EJ, Sinusas AJ, Liu C, Gullberg GT, Seo Y. Data Management and Network Architecture Effect on Performance Variability in Direct Attenuation Correction via Deep Learning for Cardiac SPECT: A Feasibility Study. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:755-765. [PMID: 36059429 PMCID: PMC9438341 DOI: 10.1109/trpms.2021.3138372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Attenuation correction (AC) is important for accurate interpretation of SPECT myocardial perfusion imaging (MPI). However, it is challenging to perform AC in dedicated cardiac systems not equipped with a transmission imaging capability. Previously, we demonstrated the feasibility of generating attenuation-corrected SPECT images using a deep learning technique (SPECTDL) directly from non-corrected images (SPECTNC). However, we observed performance variability across patients which is an important factor for clinical translation of the technique. In this study, we investigate the feasibility of overcoming the performance variability across patients for the direct AC in SPECT MPI by proposing to develop an advanced network and a data management strategy. To investigate, we compared the accuracy of the SPECTDL for the conventional U-Net and Wasserstein cycle GAN (WCycleGAN) networks. To manage the training data, clustering was applied to a representation of data in the lower-dimensional space, and the training data were chosen based on the similarity of data in this space. Quantitative analysis demonstrated that DL model with an advanced network improves the global performance for the AC task with the limited data. However, the regional results were not improved. The proposed data management strategy demonstrated that the clustered training has potential benefit for effective training.
Collapse
Affiliation(s)
- Mahsa Torkaman
- Radiology and Biomedical Imaging Department, University of California, San Francisco, CA, USA
| | - Jaewon Yang
- Radiology and Biomedical Imaging Department, University of California, San Francisco, CA, USA
| | - Luyao Shi
- Biomedical Engineering Department, Yale University, New Haven, CT, USA
| | - Rui Wang
- Radiology and Biomedical Imaging Department, Yale University, New Haven, CT, USA
| | - Edward J Miller
- Radiology and Biomedical Imaging Department, Yale University, New Haven, CT, USA
| | - Albert J Sinusas
- Biomedical Engineering Department, Yale University, New Haven, CT, USA; Radiology and Biomedical Imaging Department, Yale University, New Haven, CT, USA
| | - Chi Liu
- Biomedical Engineering Department, Yale University, New Haven, CT, USA; Radiology and Biomedical Imaging Department, Yale University, New Haven, CT, USA
| | - Grant T Gullberg
- Radiology and Biomedical Imaging Department, University of California, San Francisco, CA, USA
| | - Youngho Seo
- Radiology and Biomedical Imaging Department, University of California, San Francisco, CA, USA
| |
Collapse
|
25
|
Chen X, Zhou B, Xie H, Shi L, Liu H, Holler W, Lin M, Liu YH, Miller EJ, Sinusas AJ, Liu C. Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac SPECT. Eur J Nucl Med Mol Imaging 2022; 49:3046-3060. [PMID: 35169887 PMCID: PMC9253078 DOI: 10.1007/s00259-022-05718-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 02/06/2022] [Indexed: 12/22/2022]
Abstract
PURPOSE Deep-learning-based attenuation correction (AC) for SPECT includes both indirect and direct approaches. Indirect approaches generate attenuation maps (μ-maps) from emission images, while direct approaches predict AC images directly from non-attenuation-corrected (NAC) images without μ-maps. For dedicated cardiac SPECT scanners with CZT detectors, indirect approaches are challenging due to the limited field-of-view (FOV). In this work, we aim to 1) first develop novel indirect approaches to improve the AC performance for dedicated SPECT; and 2) compare the AC performance between direct and indirect approaches for both general purpose and dedicated SPECT. METHODS For dedicated SPECT, we developed strategies to predict truncated μ-maps from NAC images reconstructed with a small matrix, or full μ-maps from NAC images reconstructed with a large matrix using 270 anonymized clinical studies scanned on a GE Discovery NM/CT 570c SPECT/CT. For general purpose SPECT, we implemented direct and indirect approaches using 400 anonymized clinical studies scanned on a GE NM/CT 850c SPECT/CT. NAC images in both photopeak and scatter windows were input to predict μ-maps or AC images. RESULTS For dedicated SPECT, the averaged normalized mean square error (NMSE) using our proposed strategies with full μ-maps was 1.20 ± 0.72% as compared to 2.21 ± 1.17% using the previous direct approaches. The polar map absolute percent error (APE) using our approaches was 3.24 ± 2.79% (R2 = 0.9499) as compared to 4.77 ± 3.96% (R2 = 0.9213) using direct approaches. For general purpose SPECT, the averaged NMSE of the predicted AC images using the direct approaches was 2.57 ± 1.06% as compared to 1.37 ± 1.16% using the indirect approaches. CONCLUSIONS We developed strategies of generating μ-maps for dedicated cardiac SPECT with small FOV. For both general purpose and dedicated SPECT, indirect approaches showed superior performance of AC than direct approaches.
Collapse
Affiliation(s)
- Xiongchao Chen
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Bo Zhou
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Huidong Xie
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Luyao Shi
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Hui Liu
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Engineering Physics, Tsinghua University, Beijing, People's Republic of China
| | | | - MingDe Lin
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Visage Imaging, Inc, San Diego, CA, USA
| | - Yi-Hwa Liu
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
- Department of Biomedical Imaging and Radiological Sciences, School of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Edward J Miller
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
| | - Albert J Sinusas
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA
- Department of Internal Medicine (Cardiology), Yale University School of Medicine, New Haven, CT, USA
| | - Chi Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA.
- Department of Radiology and Biomedical Imaging, Yale University, CT, New Haven, USA.
| |
Collapse
|
26
|
Muscogiuri G, Guglielmo M, Serra A, Gatti M, Volpato V, Schoepf UJ, Saba L, Cau R, Faletti R, McGill LJ, De Cecco CN, Pontone G, Dell’Aversana S, Sironi S. Multimodality Imaging in Ischemic Chronic Cardiomyopathy. J Imaging 2022; 8:jimaging8020035. [PMID: 35200737 PMCID: PMC8877428 DOI: 10.3390/jimaging8020035] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 01/23/2022] [Accepted: 01/27/2022] [Indexed: 02/01/2023] Open
Abstract
Ischemic chronic cardiomyopathy (ICC) is still one of the most common cardiac diseases leading to the development of myocardial ischemia, infarction, or heart failure. The application of several imaging modalities can provide information regarding coronary anatomy, coronary artery disease, myocardial ischemia and tissue characterization. In particular, coronary computed tomography angiography (CCTA) can provide information regarding coronary plaque stenosis, its composition, and the possible evaluation of myocardial ischemia using fractional flow reserve CT or CT perfusion. Cardiac magnetic resonance (CMR) can be used to evaluate cardiac function as well as the presence of ischemia. In addition, CMR can be used to characterize the myocardial tissue of hibernated or infarcted myocardium. Echocardiography is the most widely used technique to achieve information regarding function and myocardial wall motion abnormalities during myocardial ischemia. Nuclear medicine can be used to evaluate perfusion in both qualitative and quantitative assessment. In this review we aim to provide an overview regarding the different noninvasive imaging techniques for the evaluation of ICC, providing information ranging from the anatomical assessment of coronary artery arteries to the assessment of ischemic myocardium and myocardial infarction. In particular this review is going to show the different noninvasive approaches based on the specific clinical history of patients with ICC.
Collapse
Affiliation(s)
- Giuseppe Muscogiuri
- Department of Radiology, Istituto Auxologico Italiano IRCCS, San Luca Hospital, University Milano Bicocca, 20149 Milan, Italy
- Correspondence: ; Tel.: +39-329-404-9840
| | - Marco Guglielmo
- Department of Cardiology, Division of Heart and Lungs, Utrecht University, Utrecht University Medical Center, 3584 Utrecht, The Netherlands;
| | - Alessandra Serra
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, 09042 Cagliari, Italy; (A.S.); (L.S.); (R.C.)
| | - Marco Gatti
- Radiology Unit, Department of Surgical Sciences, University of Turin, 10124 Turin, Italy; (M.G.); (R.F.)
| | - Valentina Volpato
- Department of Cardiac, Neurological and Metabolic Sciences, Istituto Auxologico Italiano IRCCS, San Luca Hospital, University Milano Bicocca, 20149 Milan, Italy;
| | - Uwe Joseph Schoepf
- Department of Radiology and Radiological Science, MUSC Ashley River Tower, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA; (U.J.S.); (L.J.M.)
| | - Luca Saba
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, 09042 Cagliari, Italy; (A.S.); (L.S.); (R.C.)
| | - Riccardo Cau
- Department of Radiology, Azienda Ospedaliero Universitaria (A.O.U.), di Cagliari-Polo di Monserrato, 09042 Cagliari, Italy; (A.S.); (L.S.); (R.C.)
| | - Riccardo Faletti
- Radiology Unit, Department of Surgical Sciences, University of Turin, 10124 Turin, Italy; (M.G.); (R.F.)
| | - Liam J. McGill
- Department of Radiology and Radiological Science, MUSC Ashley River Tower, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA; (U.J.S.); (L.J.M.)
| | - Carlo Nicola De Cecco
- Division of Cardiothoracic Imaging, Nuclear Medicine and Molecular Imaging, Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA 30322, USA;
| | | | - Serena Dell’Aversana
- Department of Radiology, Ospedale S. Maria Delle Grazie—ASL Napoli 2 Nord, 80078 Pozzuoli, Italy;
| | - Sandro Sironi
- School of Medicine and Post Graduate School of Diagnostic Radiology, University of Milano-Bicocca, 20126 Milan, Italy;
- Department of Radiology, ASST Papa Giovanni XXIII, 24127 Bergamo, Italy
| |
Collapse
|
27
|
Murata T. [[SPECT] 5. Application of Artificial Intelligence in Nuclear Medicine for SPECT]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1230-1236. [PMID: 36261360 DOI: 10.6009/jjrt.2022-2096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
|
28
|
McMillan AB, Bradshaw TJ. Artificial Intelligence-Based Data Corrections for Attenuation and Scatter in Position Emission Tomography and Single-Photon Emission Computed Tomography. PET Clin 2021; 16:543-552. [PMID: 34364816 PMCID: PMC10562009 DOI: 10.1016/j.cpet.2021.06.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Recent developments in artificial intelligence (AI) technology have enabled new developments that can improve attenuation and scatter correction in PET and single-photon emission computed tomography (SPECT). These technologies will enable the use of accurate and quantitative imaging without the need to acquire a computed tomography image, greatly expanding the capability of PET/MR imaging, PET-only, and SPECT-only scanners. The use of AI to aid in scatter correction will lead to improvements in image reconstruction speed, and improve patient throughput. This article outlines the use of these new tools, surveys contemporary implementation, and discusses their limitations.
Collapse
Affiliation(s)
- Alan B McMillan
- Department of Radiology, University of Wisconsin, 3252 Clinical Science Center, 600 Highland Avenue, Madison, WI 53792, USA.
| | - Tyler J Bradshaw
- Department of Radiology, University of Wisconsin, 3252 Clinical Science Center, 600 Highland Avenue, Madison, WI 53792, USA. https://twitter.com/tybradshaw11
| |
Collapse
|
29
|
Chen Y, Goorden MC, Beekman FJ. Convolutional neural network based attenuation correction for 123I-FP-CIT SPECT with focused striatum imaging. Phys Med Biol 2021; 66. [PMID: 34492646 DOI: 10.1088/1361-6560/ac2470] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2021] [Accepted: 09/07/2021] [Indexed: 11/12/2022]
Abstract
SPECT imaging with123I-FP-CIT is used for diagnosis of neurodegenerative disorders like Parkinson's disease. Attenuation correction (AC) can be useful for quantitative analysis of123I-FP-CIT SPECT. Ideally, AC would be performed based on attenuation maps (μ-maps) derived from perfectly registered CT scans. Suchμ-maps, however, are most times not available and possible errors in image registration can induce quantitative inaccuracies in AC corrected SPECT images. Earlier, we showed that a convolutional neural network (CNN) based approach allows to estimate SPECT-alignedμ-maps for full brain perfusion imaging using only emission data. Here we investigate the feasibility of similar CNN methods for axially focused123I-FP-CIT scans. We tested our approach on a high-resolution multi-pinhole prototype clinical SPECT system in a Monte Carlo simulation study. Three CNNs that estimateμ-maps in a voxel-wise, patch-wise and image-wise manner were investigated. As the added value of AC on clinical123I-FP-CIT scans is still debatable, the impact of AC was also reported to check in which cases CNN based AC could be beneficial. AC using the ground truthμ-maps (GT-AC) and CNN estimatedμ-maps (CNN-AC) were compared with the case when no AC was done (No-AC). Results show that the effect of using GT-AC versus CNN-AC or No-AC on striatal shape and symmetry is minimal. Specific binding ratios (SBRs) from localized regions show a deviation from GT-AC≤2.5% for all three CNN-ACs while No-AC systematically underestimates SBRs by 13.1%. A strong correlation (r≥0.99) was obtained between GT-AC based SBRs and SBRs from CNN-ACs and No-AC. Absolute quantification (in kBq ml-1) shows a deviation from GT-AC within 2.2% for all three CNN-ACs and of 71.7% for No-AC. To conclude, all three CNNs show comparable performance in accurateμ-map estimation and123I-FP-CIT quantification. CNN-estimatedμ-map can be a promising substitute for CT-basedμ-map.
Collapse
Affiliation(s)
- Yuan Chen
- Section Biomedical Imaging, Department of Radiation, Science and Technology, Delft University of Technology, Delft, The Netherlands
| | - Marlies C Goorden
- Section Biomedical Imaging, Department of Radiation, Science and Technology, Delft University of Technology, Delft, The Netherlands
| | - Freek J Beekman
- Section Biomedical Imaging, Department of Radiation, Science and Technology, Delft University of Technology, Delft, The Netherlands.,MILabs B.V., Utrecht, The Netherlands.,Department of Translational Neuroscience, Brain Center Rudolf Magnus, University Medical Center Utrecht, The Netherlands
| |
Collapse
|