1
|
Fu W, Zhang Y, Mehta K, Chen A, Musunuru HB, Pucci P, Kubis J, Huq MS. Evaluating intra-fractional tumor motion in lung stereotactic radiotherapy with deep inspiration breath-hold. J Appl Clin Med Phys 2024:e14414. [PMID: 38803045 DOI: 10.1002/acm2.14414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2024] [Revised: 04/19/2024] [Accepted: 05/08/2024] [Indexed: 05/29/2024] Open
Abstract
PURPOSE To evaluate the intra-fractional tumor motion in lung stereotactic body radiotherapy (SBRT) with deep inspiration breath-hold (DIBH), and to investigate the adequacy of the current planning target volume (PTV) margins. METHODS Twenty-eight lung SBRT patients with DIBH were selected in this study. Among the lesions, twenty-three were at right or left lower lobe, two at right middle lobe, and three at right or left upper lobe. Post-treatment gated cone-beam computed tomography (CBCT) was acquired to quantify the intra-fractional tumor shift at each treatment. These obtained shifts were then used to calculate the required PTV margin, which was compared with the current applied margin of 5 mm margin in anterior-posterior (AP) and right-left (RL) directions and 8 mm in superior-inferior (SI) direction. The beam delivery time was prolonged with DIBH. The actual beam delivery time with DIBH (Tbeam_DIBH) was compared with the beam delivery time without DIBH (Tbeam_wo_DIBH) for the corresponding SBRT plan. RESULTS A total of 113 treatments were analyzed. At six treatments (5.3%), the shifts exceeded the tolerance defined by the current PTV margin. The average shifts were 0.0 ± 1.9 mm, 0.1±1.5 mm, and -0.5 ± 3.7 mm in AP, RL, and SI directions, respectively. The required PTV margins were determined to be 4.5, 3.9, and 7.4 mm in AP, RL, and SI directions, respectively. The average Tbeam_wo_DIBH and Tbeam_DIBH were 2.4 ± 0.4 min and 3.6 ± 1.5 min, respectively. The average treatment slot for lung SBRT with DIBH was 25.3 ± 7.9 min. CONCLUSION Intra-fractional tumor motion is the predominant source of treatment uncertainties in CBCT-guided lung SBRT with DIBH. The required PTV margin should be determined based on data specific to each institute, considering different techniques and populations. Our data indicate that our current applied PTV margin is adequate, and it is possible to reduce further in the RL direction. The time increase of Tbeam_DIBH, relative to the treatment slot, is not clinically significant.
Collapse
Affiliation(s)
- Weihua Fu
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Yongqian Zhang
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Kiran Mehta
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Alex Chen
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Hima Bindu Musunuru
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Pietro Pucci
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - Jason Kubis
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA
| |
Collapse
|
2
|
Wu X, Amstutz F, Weber DC, Unkelbach J, Lomax AJ, Zhang Y. Patient-specific quality assurance for deformable IMRT/IMPT dose accumulation: Proposition and validation of energy conservation based validation criterion. Med Phys 2023; 50:7130-7138. [PMID: 37345380 DOI: 10.1002/mp.16564] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 04/17/2023] [Accepted: 06/05/2023] [Indexed: 06/23/2023] Open
Abstract
BACKGROUND Deformable image registration (DIR)-based dose accumulation (DDA) is regularly used in adaptive radiotherapy research. However, the applicability and reliability of DDA for direct clinical usage are still being debated. One primary concern is the validity of DDA, particularly for scenarios with substantial anatomical changes, for which energy-conservation problems were observed in conceptual studies. PURPOSE We present and validate an energy-conservation (EC)-based DDA validation workflow and further investigate its usefulness for actual patient data, specifically for lung cancer cases. METHODS For five non-small cell lung cancer (NSCLC) patients, DDA based on five selective DIR methods were calculated for five different treatment plans, which include one intensity-modulated photon therapy (IMRT), two intensity-modulated proton therapy (IMPT), and two combined proton-photon therapy (CPPT) plans. All plans were optimized on the planning CT (planCT) acquired in deep inspiration breath-hold (DIBH) and were re-optimized on the repeated DIBH CTs of three later fractions. The resulting fractional doses were warped back to the planCT using each DIR. An EC-based validation of the accumulation process was implemented and applied to all DDA results. Correlations between relative organ mass/volume variations and the extent of EC violation were then studied using Bayesian linear regression (BLR). RESULTS For most OARs, EC violation within 10% is observed. However, for the PTVs and GTVs with substantial regression, severe overestimation of the fractional energy was found regardless of treatment type and applied DIR method. BLR results show that EC violation is linearly correlated to the relative mass variation (R^2 > 0.95) and volume variation (R^2 > 0.60). CONCLUSION DDA results should be used with caution in regions with high mass/volume variation for intensity-based DIRs. EC-based validation is a useful approach to provide patient-specific quality assurance of the validity of DDA in radiotherapy.
Collapse
Affiliation(s)
- Xin Wu
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Information Technology & Electrical Engineering, ETH Zurich, Zurich, Switzerland
| | - Florian Amstutz
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Physics, ETH Zurich, Zurich, Switzerland
| | - Damien C Weber
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jan Unkelbach
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Antony J Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
- Department of Physics, ETH Zurich, Zurich, Switzerland
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, Villigen, Switzerland
| |
Collapse
|
3
|
Håkansson K, Josipovic M, Ottosson W, Behrens CP, Vogelius IR, Persson G. Evaluating the dosimetric effect of intra-fractional variations in deep inspiration breath-hold radiotherapy - a proof-of-concept study. Acta Oncol 2023; 62:1246-1250. [PMID: 37738385 DOI: 10.1080/0284186x.2023.2259084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 09/10/2023] [Indexed: 09/24/2023]
Affiliation(s)
- K Håkansson
- Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - M Josipovic
- Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, Faculty of Health Science, University of Copenhagen, Copenhagen, Denmark
| | - W Ottosson
- Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark
| | - C P Behrens
- Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark
- Department of Health Technology, Technical University of Denmark, Roskilde, Denmark
| | - I R Vogelius
- Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
- Department of Clinical Medicine, Faculty of Health Science, University of Copenhagen, Copenhagen, Denmark
| | - G Persson
- Department of Clinical Medicine, Faculty of Health Science, University of Copenhagen, Copenhagen, Denmark
- Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Copenhagen, Denmark
| |
Collapse
|
4
|
Nankali S, Hansen R, Worm E, Yates ES, Thomsen MS, Offersen B, Poulsen PR. Accuracy and potential improvements of surface-guided breast cancer radiotherapy in deep inspiration breath-hold with daily image-guidance. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac9109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 09/09/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Radiotherapy of left-sided breast cancer in deep inspiration breath-hold (DIBH) reduces the heart dose. Surface guided radiotherapy (SGRT) can guide the DIBH, but the accuracy is subject to variations in the chest wall position relative to the patient surface. Approach. In this study, ten left-sided breast cancer patients received DIBH radiotherapy with tangential fields in 15–18 fractions. After initial SGRT setup in free breathing an orthogonal MV/kV image pair was acquired during SGRT-guided breath-hold. The couch was corrected to align the chest wall during another breath-hold, and a new SGRT reference surface was acquired for the gating. The chest wall position error during treatment was determined from continuous cine MV images in the imager direction perpendicular to the cranio-caudal direction. A treatment error budget was made with individual contributions from the online registration of the setup MV image, the difference in breath-hold level between setup imaging and SGRT reference surface acquisition, the SGRT level during treatment, and intra-fraction shifts of the chest wall relative to the SGRT reference surface. In addition to the original setup protocol (Scenario A), SGRT was also simulated with better integration of image-guidance by capturing either the new reference surface (Scenario B) or the SGRT positional signal (Scenario C) simultaneously with the setup MV image, and accounting for the image-guided couch correction by shifting the SGRT reference surface digitally. Main results. In general, the external SGRT signal correlated well with the internal chest wall position error (correlation coefficient >0.7 for 75% of field deliveries), but external-to-internal target position offsets above 2 mm occasionally occurred (13% of fractions). The PTV margin required to account for the treatment error was 3.5 mm (Scenario A), 3.4 mm (B), and 3.1 mm (C). Significance. Further integration of SGRT with image-guidance may improve treatment accuracy and workflow although the current study did not show large accuracy improvements of scenario B and C compared to scenario A.
Collapse
|
5
|
Mørkeset ST, Lervåg C, Lund JÅ, Jensen C. Clinical experience of volumetric-modulated flattening filter free stereotactic body radiation therapy of lesions in the lung with deep inspiration breath-hold. J Appl Clin Med Phys 2022; 23:e13733. [PMID: 35867387 PMCID: PMC9512343 DOI: 10.1002/acm2.13733] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 05/19/2022] [Accepted: 06/23/2022] [Indexed: 11/05/2022] Open
Abstract
This clinical study aimed to evaluate lung cancer patients' ability to perform deep inspiration breath-hold (DIBH) during CT simulation and throughout the treatment course of stereotactic body radiation therapy (SBRT). In addition, target sizes, organ at risk (OAR) sizes, and doses to the respective volumes in filter-free volumetric-modulated arc therapy plans performed under free-breathing (FB) and DIBH conditions were evaluated. Twenty-one patients with peripheral lesions were included, of which 13 were eligible for SBRT. All patients underwent training for breath-hold during CT, and if they complied with the requirements, two CT scans were obtained: CT scan in DIBH and a four-dimensional CT scan in FB. The treatment plans in FB and DIBH were generated, and the dose parameters and volume sizes were compared. The endpoints for evaluation were patient compliance, target dose coverage, and doses to the OARs. This clinical study showed high patient DIBH compliance during both CT simulation and treatment for patients with lung cancer. A significant reduction in target volumes was achieved with SBRT in DIBH, in addition to significantly decreased doses to the heart, chest wall, and lungs. DIBH in SBRT of lung lesions is feasible, and a routine to manage intra-fractional deviation should be established upon implementation.
Collapse
Affiliation(s)
- Siri T Mørkeset
- Department of Oncology and Rehabilitation, Møre and Romsdal Hospital Trust, Ålesund Hospital, Ålesund, Norway
| | - Christoffer Lervåg
- Department of Oncology and Rehabilitation, Møre and Romsdal Hospital Trust, Ålesund Hospital, Ålesund, Norway
| | - Jo-Åsmund Lund
- Department of Oncology and Rehabilitation, Møre and Romsdal Hospital Trust, Ålesund Hospital, Ålesund, Norway.,Department of Health Sciences in Ålesund, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Ålesund, Norway
| | - Christer Jensen
- Department of Health Sciences in Ålesund, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology (NTNU), Ålesund, Norway.,Department of Medicine and Healthcare, Møre and Romsdal Hospital Trust, Ålesund Hospital, Ålesund, Norway
| |
Collapse
|
6
|
Maradia V, van de Water S, Meer D, Weber DC, Lomax AJ, Psoroulas S. Ultra-fast pencil beam scanning proton therapy for locally advanced non-small-cell lung cancers: field delivery within a single breath-hold. Radiother Oncol 2022; 174:23-29. [PMID: 35788354 DOI: 10.1016/j.radonc.2022.06.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 06/03/2022] [Accepted: 06/22/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE The use of motion mitigation techniques such as breath-hold can reduce the dosimetric uncertainty of lung cancer proton therapy. We studied the feasibility of pencil beam scanning (PBS) proton therapy field delivery within a single breath-hold at PSI's Gantry 2. METHODS In PBS proton therapy, the delivery time for a field is determined by the beam-on time and the dead time between proton spots (the time required to change the energy and/or lateral position). We studied ways to reduce beam-on and lateral scanning time, without sacrificing dosimetric plan quality, aiming at a single field delivery time of 15 seconds at maximum. We tested this approach on 10 lung cases with varying target volumes. To reduce the beam-on time, we increased the beam current at the isocenter by developing new beam optics for PSI's PROSCAN beamline and Gantry 2. To reduce the dead time between the spots, we used spot-reduced plan optimization. RESULTS We found that it is possible to achieve conventional fractionated (2 Gy(RBE)/fraction) and hypofractionated (6 Gy(RBE)/fraction) field delivery times within a single breath-hold (<15 sec) for a variety non-small-cell lung cancer cases. CONCLUSION In summary, the combination of spot reduction and improved beam line transmission is a promising approach for the treatment of mobile tumours within clinically achievable breath-hold durations.
Collapse
Affiliation(s)
- Vivek Maradia
- Paul Scherrer Institute, Switzerland; ETH Zurich, Switzerland.
| | - Steven van de Water
- Paul Scherrer Institute, Switzerland; Department of Radiation Oncology, Amsterdam UMC, Vrije Universiteit Amsterdam, Cancer Center Amsterdam, Amsterdam, The Netherlands
| | | | - Damien C Weber
- Paul Scherrer Institute, Switzerland; University Hospital Zurich, Switzerland; University Hospital Bern, University of Bern, Switzerland
| | - Antony J Lomax
- Paul Scherrer Institute, Switzerland; ETH Zurich, Switzerland
| | | |
Collapse
|
7
|
Aznar M, Ntentas G, Enmark M, Flampouri S, Meidhal Petersen P, Ricardi U, Levis M. The role of motion management and position verification in lymphoma radiotherapy. Br J Radiol 2021; 94:20210618. [PMID: 34677090 PMCID: PMC8553184 DOI: 10.1259/bjr.20210618] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 09/09/2021] [Accepted: 09/10/2021] [Indexed: 12/17/2022] Open
Abstract
In the last decades, the substantial technical progress in radiation oncology offered the opportunity for more accurate planning and delivery of treatment. At the same time, the evolution of systemic treatment and the advent of modern diagnostic tools allowed for more accurate staging and consequently a safe reduction of radiotherapy (RT) target volumes and RT doses in the treatment of lymphomas. As a result, incidental irradiation of organs at risk was reduced, with a consequent reduction of severe late toxicity in long-term lymphoma survivors. Nevertheless, these innovations warrant that professionals pay attention to concurrently ensure precise planning and dose delivery to the target volume and safe sparing of the organs at risk. In particular, target and organ motion should be carefully managed in order to prevent any compromise of treatment efficacy. Several aspects should be taken into account during the treatment pathway to minimise uncertainties and to apply a valuable motion management strategy, when needed. These include: reliable image registration between diagnostic and planning radiologic exams to facilitate the contouring process, image guidance to limit positioning uncertainties and to ensure the accuracy of dose delivery and management of lung motion through procedures of respiratory gating and breath control. In this review, we will cover the current clinical approaches to minimise these uncertainties in patients treated with modern RT techniques, with a particular focus on mediastinal lymphoma. In addition, since uncertainties have a different impact on the dose deposition of protons compared to conventional x-rays, the role of motion management and position verification in proton beam therapy (PBT) will be discussed in a separate section.
Collapse
Affiliation(s)
| | | | | | - Stella Flampouri
- Department of Radiation Oncology, Emory University, Atlanta, GA, USA
| | | | | | - Mario Levis
- Department of Oncology, University of Torino, Turin, Italy
| |
Collapse
|
8
|
Taasti VT, Hattu D, Vaassen F, Canters R, Velders M, Mannens J, van Loon J, Rinaldi I, Unipan M, van Elmpt W. Treatment planning and 4D robust evaluation strategy for proton therapy of lung tumors with large motion amplitude. Med Phys 2021; 48:4425-4437. [PMID: 34214201 PMCID: PMC8456954 DOI: 10.1002/mp.15067] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 05/29/2021] [Accepted: 06/21/2021] [Indexed: 12/25/2022] Open
Abstract
Purpose Intensity‐modulated proton therapy (IMPT) for lung tumors with a large tumor movement is challenging due to loss of robustness in the target coverage. Often an upper cut‐off at 5‐mm tumor movement is used for proton patient selection. In this study, we propose (1) a robust and easily implementable treatment planning strategy for lung tumors with a movement larger than 5 mm, and (2) a four‐dimensional computed tomography (4DCT) robust evaluation strategy for evaluating the dose distribution on the breathing phases. Materials and methods We created a treatment planning strategy based on the internal target volume (ITV) concept (aim 1). The ITV was created as a union of the clinical target volumes (CTVs) on the eight 4DCT phases. The ITV expanded by 2 mm was the target during robust optimization on the average CT (avgCT). The clinical plan acceptability was judged based on a robust evaluation, computing the voxel‐wise min and max (VWmin/max) doses over 28 error scenarios (range and setup errors) on the avgCT. The plans were created in RayStation (RaySearch Laboratories, Stockholm, Sweden) using a Monte Carlo dose engine, commissioned for our Mevion S250i Hyperscan system (Mevion Medical Systems, Littleton, MA, USA). We developed a new 4D robust evaluation approach (4DRobAvg; aim 2). The 28 scenario doses were computed on each individual 4DCT phase. For each scenario, the dose distributions on the individual phases were deformed to the reference phase and combined to a weighted sum, resulting in 28 weighted sum scenario dose distributions. From these 28 scenario doses, VWmin/max doses were computed. This new 4D robust evaluation was compared to two simpler 4D evaluation strategies: re‐computing the nominal plan on each individual 4DCT phase (4DNom) and computing the robust VWmin/max doses on each individual phase (4DRobInd). The treatment planning and dose evaluation strategies were evaluated for 16 lung cancer patients with tumor movement of 4–26 mm. Results The ratio of the ITV and CTV volumes increased linearly with the tumor amplitude, with an average ratio of 1.4. Despite large ITV volumes, a clinically acceptable plan fulfilling all target and organ at risk (OAR) constraints was feasible for all patients. The 4DNom and 4DRobInd evaluation strategies were found to under‐ or overestimate the dosimetric effect of the tumor movement, respectively. 4DRobInd showed target underdosage for five patients, not observed in the robust evaluation on the avgCT or in 4DRobAvg. The accuracy of dose deformation used in 4DRobAvg was quantified and found acceptable, with differences for the dose‐volume parameters below 1 Gy in most cases. Conclusion The proposed ITV‐based planning strategy on the avgCT was found to be a clinically feasible approach with adequate tumor coverage and no OAR overdosage even for large tumor movement. The new proposed 4D robust evaluation, 4DRobAvg, was shown to give an easily interpretable understanding of the effect of respiratory motion dose distribution, and to give an accurate estimate of the dose delivered in the different breathing phases.
Collapse
Affiliation(s)
- Vicki Trier Taasti
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Djoya Hattu
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Femke Vaassen
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Richard Canters
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Marije Velders
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Jolein Mannens
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Judith van Loon
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Ilaria Rinaldi
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Mirko Unipan
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| | - Wouter van Elmpt
- Department of Radiation Oncology (MAASTRO), GROW - School for Oncology, Maastricht University Medical Centre+, Maastricht, Netherlands
| |
Collapse
|
9
|
Stera S, Miebach G, Buergy D, Dreher C, Lohr F, Wurster S, Rödel C, Marcella S, Krug D, Frank A G, Ehmann M, Fleckenstein J, Blanck O, Boda-Heggemann J. Liver SBRT with active motion-compensation results in excellent local control for liver oligometastases: An outcome analysis of a pooled multi-platform patient cohort. Radiother Oncol 2021; 158:230-236. [PMID: 33667585 DOI: 10.1016/j.radonc.2021.02.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 02/10/2021] [Accepted: 02/24/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Local treatment of metastases in combination with systemic therapy can prolong survival of oligo-metastasized patients. To fully exploit this potential, safe and effective treatments are needed to ensure long-term metastases control. Stereotactic body radiotherapy (SBRT) is one means, however, for moving liver tumors correct delivery of high doses is challenging. After validating equal in-vivo treatment accuracy, we analyzed a pooled multi-platform liver-SBRT-database for clinical outcome. METHODS Local control (LC), progression-free interval (PFI), overall survival (OS), predictive factors and toxicity was evaluated in 135 patients with 227 metastases treated by gantry-based SBRT (deep-inspiratory breath-hold-gating; n = 71) and robotic-based SBRT (fiducial-tracking, n = 156) with mean gross tumor volume biological effective dose (GTV-BEDα/β=10Gy) of 146.6 Gy10. RESULTS One-, and five-year LC was 90% and 68.7%, respectively. On multivariate analysis, LC was significantly predicted by colorectal histology (p = 0.006). Median OS was 20 months with one- and two-year OS of 67% and 37%. On multivariate analysis, ECOG-status (p = 0.003), simultaneous chemotherapy (p = 0.003), time from metastasis detection to SBRT-treatment (≥2months; p = 0.021) and LC of the treated metastases (≥12 months, p < 0.009) were significant predictors for OS. One- and two-year PFI were 30.5% and 14%. Acute toxicity was mild and rare (14.4% grade I, 2.3% grade II, 0.6% grade III). Chronic °III/IV toxicities occurred in 1.1%. CONCLUSIONS Patient selection, time to treatment and sufficient doses are essential to achieve optimal outcome for SBRT with active motion compensation. Local control appears favorable compared to historical control. Long-term LC of the treated lesions was associated with longer overall survival.
Collapse
Affiliation(s)
- Susanne Stera
- University Hospital Frankfurt, Department of Radiation Oncology, Frankfurt am Main, Germany.
| | - Georgia Miebach
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Daniel Buergy
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Constantin Dreher
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Frank Lohr
- UO di Radioterapia, Dipartimento di Oncologia, Azienda Ospedaliero-Universitaria di Modena, Italy
| | - Stefan Wurster
- Saphir Radiosurgery Center, Güstrow, Germany; University Medicine Greifswald, Department of Radiation Oncology, Germany
| | - Claus Rödel
- University Hospital Frankfurt, Department of Radiation Oncology, Frankfurt am Main, Germany
| | - Szücs Marcella
- University Medicine Rostock, Department of Radiation Oncology, Germany
| | - David Krug
- Saphir Radiosurgery Center, Güstrow, Germany; University Medical Center Schleswig-Holstein, Department of Radiation Oncology, Kiel, Germany
| | - Giordano Frank A
- Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Germany
| | - Michael Ehmann
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Jens Fleckenstein
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| | - Oliver Blanck
- Saphir Radiosurgery Center, Güstrow, Germany; University Medical Center Schleswig-Holstein, Department of Radiation Oncology, Kiel, Germany
| | - Judit Boda-Heggemann
- University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Department of Radiation Oncology, Germany
| |
Collapse
|
10
|
Lundgaard AY, Josipovic M, Rechner LA, Bidstrup PE, Hansen R, Damkjaer SS, Joergensen M, Safwat A, Specht L, Hjalgrim LL, Maraldo MV. The Feasibility of Implementing Deep Inspiration Breath-Hold for Pediatric Radiation Therapy. Int J Radiat Oncol Biol Phys 2020; 106:977-984. [PMID: 32005489 DOI: 10.1016/j.ijrobp.2019.12.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 12/13/2019] [Accepted: 12/19/2019] [Indexed: 12/23/2022]
Abstract
PURPOSE Radiation therapy delivery during deep inspiration breath-hold (DIBH) reduces the irradiation of the heart and lungs and is therefore recommended for adults with mediastinal lymphoma. However, no studies have addressed the use of DIBH in children. This pilot study investigates the feasibility of and compliance with DIBH in children. METHODS AND MATERIALS Children from the age of 5 years were recruited to a training session to assess their ability to perform DIBH. No children received radiation therapy. The children were placed in a potential radiation therapy position. The DIBH was voluntary and monitored using an optical surface system providing visual feedback. Children who performed 3 stable DIBHs of 20 seconds each and remained motionless were deemed DIBH compliant. Compliance, equipment suitability, and coaching were further assessed in a semistructured interview. RESULTS We included 33 children (18 healthy and 15 hospitalized children with cancer) with a mean age of 8.5 years (range, 5-15). A total of 28 (85%) children were DIBH compliant. Twenty children were deemed immediately DIBH compliant, and 8 were deemed conditionally DIBH compliant, as DIBH compliance was presumed with custom-made immobilization and/or additional DIBH training. Mean age of the DIBH-compliant and the non-DIBH-compliant children was 8.9 years (range, 5-15) and 6 years (range, 5-9), respectively. Only 1 of 15 hospitalized children was not DIBH compliant and only 1 of all 33 children was unable to grasp the DIBH concept. The available DIBH equipment was suitable for children, and 94% reported that they were happy with training and performing DIBH. CONCLUSIONS This pilot study demonstrated that children from the age of 5 years can potentially comply with the DIBH technique and perform stable and reproducible DIBHs suitable for radiation therapy. Custom-made immobilization and adequate training will potentially increase DIBH compliance. A prospective clinical trial (NCT03315546), investigating the dosimetric benefit of radiation therapy delivery in DIBH compared with free breathing with pediatric patients, has been initiated.
Collapse
Affiliation(s)
| | - Mirjana Josipovic
- Department of Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | - Laura Ann Rechner
- Department of Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | - Pernille Envold Bidstrup
- Research Group on Psycological Aspects of Cancer, Danish Cancer Society Research Center, Copenhagen & Institute of Psychology, University of Copenhagen, Denmark
| | - Rune Hansen
- Department of Oncology, Aarhus University Hospital, Denmark
| | | | - Morten Joergensen
- Department of Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | - Akmal Safwat
- Department of Oncology, Aarhus University Hospital, Denmark
| | - Lena Specht
- Department of Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | - Lisa Lyngsie Hjalgrim
- Department of Pediatric Hematology and Oncology, Rigshospitalet, University of Copenhagen, Denmark
| | | |
Collapse
|
11
|
Josipovic M, Persson GF, Rydhög JS, Smulders B, Thomsen JB, Aznar MC. Advanced dose calculation algorithms in lung cancer radiotherapy: Implications for SBRT and locally advanced disease in deep inspiration breath hold. Phys Med 2018; 56:50-57. [PMID: 30527089 DOI: 10.1016/j.ejmp.2018.11.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 11/01/2018] [Accepted: 11/18/2018] [Indexed: 12/31/2022] Open
Abstract
PURPOSE Evaluating performance of modern dose calculation algorithms in SBRT and locally advanced lung cancer radiotherapy in free breathing (FB) and deep inspiration breath hold (DIBH). METHODS For 17 patients with early stage and 17 with locally advanced lung cancer, a plan in FB and in DIBH were generated with Anisotropic Analytical Algorithm (AAA). Plans for early stage were 3D-conformal SBRT, 45 Gy in 3 fractions, prescribed to 95% isodose covering 95% of PTV and aiming for 140% dose centrally in the tumour. Locally advanced plans were volumetric modulated arc therapy, 66 Gy in 33 fractions, prescribed to mean PTV dose. Calculation grid size was 1 mm for SBRT and 2.5 mm for locally advanced plans. All plans were recalculated with AcurosXB with same MU as in AAA, for comparison on target coverage and dose to risk organs. RESULTS Lung volume increased in DIBH, resulting in decreased lung density (6% for early and 13% for locally-advanced group). In SBRT, AAA overestimated mean and near-minimum PTV dose (p-values < 0.01) compared to AcurosXB, with largest impact in DIBH (differences of up to 11 Gy). These clinically relevant differences may be a combination of small targets and large dose gradients within the PTV. In locally advanced group, AAA overestimated mean GTV, CTV and PTV doses by median less than 0.8 Gy and near-minimum doses by median 0.4-2.7 Gy. No clinically meaningful difference was observed for lung and heart dose metrics between the algorithms, for both FB and DIBH. CONCLUSIONS AAA overestimated target coverage compared to AcurosXB, especially in DIBH for SBRT.
Collapse
Affiliation(s)
- Mirjana Josipovic
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Blegdamsvej17, 2100 Copenhagen, Denmark.
| | - Gitte Fredberg Persson
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.
| | - Jonas Scherman Rydhög
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Blegdamsvej17, 2100 Copenhagen, Denmark; Department of Radiation Physics, Skåne University Hospital, Lund University, 221 85 Lund, Sweden.
| | - Bob Smulders
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.
| | - Jakob Borup Thomsen
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark.
| | - Marianne Camille Aznar
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark; Faculty of Medical Sciences, University of Copenhagen, Blegdamsvej 3B, 2100 Copenhagen, Denmark; Manchester Cancer Research Centre, Division of Cancer Science, University of Manchester, Wilmslow Road, Manchester M20 4BX, UK; Clinical Trial Service Unit, Nuffield Department of Population Health, University of Oxford, Oxford OX3 7LF, UK.
| |
Collapse
|
12
|
Lundgaard AY, Hjalgrim LL, Rechner LA, Josipovic M, Joergensen M, Aznar MC, Berthelsen AK, Borgwardt L, Johansen C, Loft A, Safwat A, Vaalavirta L, Specht L, Maraldo MV. TEDDI: radiotherapy delivery in deep inspiration for pediatric patients - a NOPHO feasibility study. Radiat Oncol 2018; 13:56. [PMID: 29587881 PMCID: PMC5872576 DOI: 10.1186/s13014-018-1003-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 03/16/2018] [Indexed: 01/30/2023] Open
Abstract
Background Radiotherapy (RT) delivered in deep inspiration breath-hold (DIBH) is a simple technique, in which changes in patient anatomy can significantly reduce the irradiation of the organs at risk (OARs) surrounding the treatment target. DIBH is routinely used in the treatment of some adult patients to diminish the risk of late effects; however, no formalized studies have addressed the potential benefit of DIBH in children. Methods/Design TEDDI is a multicenter, non-randomized, feasibility study. The study investigates the dosimetric benefit of RT delivered in DIBH compared to free breathing (FB) in pediatric patients. Also, the study aims to establish the compliance to DIBH and to determine the accuracy and reproducibility in a pediatric setting. Pediatric patients (aged 5–17 years) with a tumor in the mediastinum or upper abdomen with the possible need of RT will be included in the study. Written informed consent is obligatory. Prior to any treatment, patients will undergo a DIBH training session followed by a diagnostic PET/CT- or CT-staging scan in both DIBH and FB. If the patient proceeds to RT, a RT planning CT scan will be performed in both DIBH and FB and two separate treatment plans will be calculated. The superior treatment plan, i.e. equal target coverage and lowest overall dose to the OARs, will be chosen for treatment. Patient comfort will be assessed daily by questionnaires and by adherence to the respiratory management procedure. Discussion RT in DIBH is expected to diminish irradiation of the OARs surrounding the treatment target and thereby reduce the risk of late effects in childhood cancer survivors. Trial registration The Danish Ethical Committee (H-16035870, approved November 24th 2016, prospectively registered). The Danish Data Protection Agency (2012–58-0004, approved January 1st 2017, prospectively registered). Registered at clinicaltrials.gov (NCT03315546, October 20th 2017, retrospectively registered).
Collapse
Affiliation(s)
- Anni Young Lundgaard
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.
| | - Lisa Lyngsie Hjalgrim
- Department of Pediatric Haematology and Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Laura Ann Rechner
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.,Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, 2100, Copenhagen, Denmark
| | - Mirjana Josipovic
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.,Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, 2100, Copenhagen, Denmark
| | - Morten Joergensen
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Marianne Camille Aznar
- Manchester Cancer Research Centre, Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester c/o Christie Hospital, Department 58, Floor 2A, Wilmslow Road, Manchester, M20 4BX, UK
| | - Anne Kill Berthelsen
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.,Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Lise Borgwardt
- Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Christoffer Johansen
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark.,Danish Cancer Society Research Center, Strandboulevarden 49, 2100, Copenhagen, Denmark
| | - Annika Loft
- Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Akmal Safwat
- Department of Clinical Oncology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus, Denmark
| | - Leila Vaalavirta
- Department of Radiation Oncology, Comprehensive Cancer Center, Helsinki University Hospital, Haartmaninkatu 4, 00290, Helsinki, Finland
| | - Lena Specht
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| | - Maja Vestmoe Maraldo
- Department of Clinical Oncology, Rigshospitalet, University of Copenhagen, Blegdamsvej 9, 2100, Copenhagen, Denmark
| |
Collapse
|
13
|
Dosimetric comparison of deep inspiration breath hold and free breathing technique in stereotactic body radiotherapy for localized lung tumor using Flattening Filter Free beam. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2018. [DOI: 10.2478/pjmpe-2018-0003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Abstract
Aim: To compare the dosimetric advantage of stereotactic body radiotherapy (SBRT) for localized lung tumor between deep inspiration breath hold technique and free breathing technique.
Materials and methods: We retrospectively included ten previously treated lung tumor patients in this dosimetric study. All the ten patients underwent CT simulation using 4D-CT free breathing (FB) and deep inspiration breath hold (DIBH) techniques. Plans were created using three coplanar full modulated arc using 6 MV flattening filter free (FFF) bream with a dose rate of 1400 MU/min. Same dose constraints for the target and the critical structures for a particular patient were used during the plan optimization process in DIBH and FB datasets. We intend to deliver 50 Gy in 5 fractions for all the patients. For standardization, all the plans were normalized at target mean of the planning target volume (PTV). Doses to the critical structures and targets were recorded from the dose volume histogram for evaluation.
Results: The mean right and left lung volumes were inflated by 1.55 and 1.60 times in DIBH scans compared to the FB scans. The mean internal target volume (ITV) increased in the FB datasets by 1.45 times compared to the DIBH data sets. The mean dose followed by standard deviation (x̄ ± σx̄) of ipsilateral lung for DIBH-SBRT and FB-SBRT plans were 7.48 ± 3.57 (Gy) and 10.23 ± 4.58 (Gy) respectively, with a mean reduction of 36.84% in DIBH-SBRT plans. Ipsilateral lung were reduced to 36.84% in DIBH plans compared to FB plans.
Conclusion: Significant dose reduction in ipsilateral lung due to the lung inflation and target motion restriction in DIBH-SBRT plans were observed compare to FB-SBRT. DIBH-SBRT plans demonstrate superior dose reduction to the normal tissues and other critical structures.
Collapse
|
14
|
The long- and short-term variability of breathing induced tumor motion in lung and liver over the course of a radiotherapy treatment. Radiother Oncol 2018; 126:339-346. [DOI: 10.1016/j.radonc.2017.09.001] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Revised: 09/01/2017] [Accepted: 09/03/2017] [Indexed: 11/19/2022]
|
15
|
Gorgisyan J, Munck af Rosenschold P, Perrin R, Persson GF, Josipovic M, Belosi MF, Engelholm SA, Weber DC, Lomax AJ. Feasibility of Pencil Beam Scanned Intensity Modulated Proton Therapy in Breath-hold for Locally Advanced Non-Small Cell Lung Cancer. Int J Radiat Oncol Biol Phys 2017; 99:1121-1128. [DOI: 10.1016/j.ijrobp.2017.08.023] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 07/13/2017] [Accepted: 08/16/2017] [Indexed: 12/25/2022]
|
16
|
Josipovic M, Persson GF, Bangsgaard JP, Specht L, Aznar MC. Deep inspiration breath-hold radiotherapy for lung cancer: impact on image quality and registration uncertainty in cone beam CT image guidance. Br J Radiol 2016; 89:20160544. [PMID: 27706950 PMCID: PMC5604920 DOI: 10.1259/bjr.20160544] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 08/20/2016] [Accepted: 10/03/2016] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE We investigated the impact of deep inspiration breath-hold (DIBH) and tumour baseline shifts on image quality and registration uncertainty in image-guided DIBH radiotherapy (RT) for locally advanced lung cancer. METHODS Patients treated with daily cone beam CT (CBCT)-guided free-breathing (FB) RT had an additional CBCT in DIBH at three fractions. These CBCT scans were offline rigidly registered (on tumour) to FB and DIBH CT scans acquired at planning. All registrations were repeated to evaluate the intraobserver uncertainty. CBCT scans were scored on degree of streak artefacts and visualization of tumour and anatomical structures. We examined the impact of tumour baseline shift between consecutive DIBHs on CBCT image quality. RESULTS CBCT scans from 15 patients were analysed. Intraobserver image registration uncertainty was approximately 2 mm in both FB and DIBH, except for the craniocaudal direction in FB, where it was >3 mm. On the 31st fraction, the intraobserver uncertainty increased compared with the second fraction. This increase was more pronounced in FB. Image quality scores improved in DIBH compared with FB for all parameters in all patients. Simulated tumour baseline shifts ≤2 mm did not affect the CBCT image quality considerably. CONCLUSION DIBH CBCT improved image quality and reduced registration uncertainty in the craniocaudal direction in image-guided RT of locally advanced lung cancer. Baseline shifts ≤2 mm in DIBH during CBCT acquisition did not affect image quality. Advances in knowledge: DIBH RT has dosimetric advantages over FB; this work demonstrates an additional benefit of DIBH in terms of registration accuracy because of improved image quality.
Collapse
Affiliation(s)
- Mirjana Josipovic
- Section of Radiotherapy, Department of Oncology, Rigshospitalet, Copenhagen, Denmark
- Niels Bohr Institute, Faculty of Science, University of Copenhagen, Copenhagen, Denmark
| | - Gitte F Persson
- Section of Radiotherapy, Department of Oncology, Rigshospitalet, Copenhagen, Denmark
| | - Jens P Bangsgaard
- Section of Radiotherapy, Department of Oncology, Rigshospitalet, Copenhagen, Denmark
| | - Lena Specht
- Section of Radiotherapy, Department of Oncology, Rigshospitalet, Copenhagen, Denmark
- Faculty of Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Marianne C Aznar
- Section of Radiotherapy, Department of Oncology, Rigshospitalet, Copenhagen, Denmark
- Niels Bohr Institute, Faculty of Science, University of Copenhagen, Copenhagen, Denmark
- Faculty of Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
17
|
Persson GF, Scherman Rydhög J, Josipovic M, Maraldo MV, Nygård L, Costa J, Berthelsen AK, Specht L, Aznar MC. Deep inspiration breath-hold volumetric modulated arc radiotherapy decreases dose to mediastinal structures in locally advanced lung cancer. Acta Oncol 2016; 55:1053-6. [PMID: 26935017 DOI: 10.3109/0284186x.2016.1142115] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2015] [Revised: 01/05/2016] [Accepted: 01/10/2016] [Indexed: 12/25/2022]
Affiliation(s)
- Gitte F Persson
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
| | - Jonas Scherman Rydhög
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- b Faculty of Science , Niels Bohr Institute, Copenhagen University , Copenhagen , Denmark
| | - Mirjana Josipovic
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- b Faculty of Science , Niels Bohr Institute, Copenhagen University , Copenhagen , Denmark
| | - Maja V Maraldo
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
| | - Lotte Nygård
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
| | - Junia Costa
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- c Department of Clinical Physiology, Nuclear Medicine and PET , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
| | - Anne K Berthelsen
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- c Department of Clinical Physiology, Nuclear Medicine and PET , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
| | - Lena Specht
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- d Faculty of Medical Sciences , Panum Institute, Copenhagen University , Copenhagen , Denmark
| | - Marianne C Aznar
- a Department of Oncology , Rigshospitalet Copenhagen University Hospital , Copenhagen , Denmark
- b Faculty of Science , Niels Bohr Institute, Copenhagen University , Copenhagen , Denmark
| |
Collapse
|
18
|
Dueck J, Knopf AC, Lomax A, Albertini F, Persson GF, Josipovic M, Aznar M, Weber DC, Munck af Rosenschöld P. Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy. Int J Radiat Oncol Biol Phys 2016; 95:534-541. [DOI: 10.1016/j.ijrobp.2015.11.015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2015] [Revised: 11/04/2015] [Accepted: 11/09/2015] [Indexed: 12/25/2022]
|
19
|
Josipovic M, Persson GF, Dueck J, Bangsgaard JP, Westman G, Specht L, Aznar MC. Geometric uncertainties in voluntary deep inspiration breath hold radiotherapy for locally advanced lung cancer. Radiother Oncol 2016; 118:510-4. [PMID: 26631647 DOI: 10.1016/j.radonc.2015.11.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Revised: 11/03/2015] [Accepted: 11/08/2015] [Indexed: 12/16/2022]
Abstract
BACKGROUND AND PURPOSE Deep inspiration breath hold (DIBH) increases lung volume and can potentially reduce treatment-related toxicity in locally advanced lung cancer. We estimated geometric uncertainties in visually guided voluntary DIBH and derived the appropriate treatment margins for different image-guidance strategies. MATERIAL AND METHODS Seventeen patients were included prospectively. An optical marker-based respiratory monitoring with visual guidance enabled comfortable DIBHs, adjusted to each patient's performance. All patients had three consecutive DIBH CTs at each of the treatment fractions 2, 16 and 31. DIBH reproducibility was evaluated as inter- and intra-fractional variations in lung volume, tumour position and differential motion between primary tumour and mediastinal lymph nodes. RESULTS Lung volume increased by median 60% in DIBH. Inter- and intra-fractional lung volume variations were median 2.1% and 1.1%, respectively. Inter- and intra-fractional uncertainties in 3D tumour position were 4.8 ± 2.8 mm and 1.7 ± 1.4 mm (mean ± SD). Inter- and intra-fractional differential motion was 4.8 ± 3.3 mm and 0.0 ± 1.1 mm. CONCLUSIONS For single targets, visually guided voluntary DIBH radiotherapy is highly reproducible provided an image-guidance strategy with tumour registration is performed. If the primary tumour is separated from the mediastinal lymph nodes, inter-fractional differential motion remains a challenge and margins must be adapted to reflect the image registration strategy.
Collapse
Affiliation(s)
- Mirjana Josipovic
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Denmark.
| | - Gitte F Persson
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark
| | - Jenny Dueck
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Denmark; Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
| | - Jens Peter Bangsgaard
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark
| | - Gunnar Westman
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark
| | - Lena Specht
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark; Faculty of Medical Sciences, University of Copenhagen, Denmark
| | - Marianne C Aznar
- Department of Oncology, Section of Radiotherapy, Rigshospitalet, Copenhagen, Denmark; Niels Bohr Institute, Faculty of Science, University of Copenhagen, Denmark; Faculty of Medical Sciences, University of Copenhagen, Denmark
| |
Collapse
|
20
|
Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review. Int J Radiat Oncol Biol Phys 2015; 94:478-92. [PMID: 26867877 DOI: 10.1016/j.ijrobp.2015.11.049] [Citation(s) in RCA: 154] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Revised: 11/03/2015] [Accepted: 11/29/2015] [Indexed: 01/06/2023]
Abstract
Several recent developments in linear accelerator-based radiation therapy (RT) such as fast multileaf collimators, accelerated intensity modulation paradigms like volumeric modulated arc therapy and flattening filter-free (FFF) high-dose-rate therapy have dramatically shortened the duration of treatment fractions. Deliverable photon dose distributions have approached physical complexity limits as a consequence of precise dose calculation algorithms and online 3-dimensional image guided patient positioning (image guided RT). Simultaneously, beam quality and treatment speed have continuously been improved in particle beam therapy, especially for scanned particle beams. Applying complex treatment plans with steep dose gradients requires strategies to mitigate and compensate for motion effects in general, particularly breathing motion. Intrafractional breathing-related motion results in uncertainties in dose delivery and thus in target coverage. As a consequence, generous margins have been used, which, in turn, increases exposure to organs at risk. Particle therapy, particularly with scanned beams, poses additional problems such as interplay effects and range uncertainties. Among advanced strategies to compensate breathing motion such as beam gating and tracking, deep inspiration breath hold (DIBH) gating is particularly advantageous in several respects, not only for hypofractionated, high single-dose stereotactic body RT of lung, liver, and upper abdominal lesions but also for normofractionated treatment of thoracic tumors such as lung cancer, mediastinal lymphomas, and breast cancer. This review provides an in-depth discussion of the rationale and technical implementation of DIBH gating for hypofractionated and normofractionated RT of intrathoracic and upper abdominal tumors in photon and proton RT.
Collapse
|
21
|
Monte Carlo calculations support organ sparing in Deep-Inspiration Breath-Hold intensity-modulated radiotherapy for locally advanced lung cancer. Radiother Oncol 2015; 117:55-63. [DOI: 10.1016/j.radonc.2015.08.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2015] [Revised: 06/10/2015] [Accepted: 08/28/2015] [Indexed: 11/17/2022]
|
22
|
Grau C, Overgaard J, Høyer M, Tanderup K, Lindegaard JC, Muren LP. Biology-guided adaptive radiotherapy (BiGART) is progressing towards clinical reality. Acta Oncol 2015; 54:1245-50. [PMID: 26390238 DOI: 10.3109/0284186x.2015.1076992] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Cai Grau
- a Department of Oncology , Aarhus University Hospital , Aarhus , Denmark
| | - Jens Overgaard
- b Department of Experimental Clinical Oncology , Aarhus University Hospital , Aarhus , Denmark
| | - Morten Høyer
- a Department of Oncology , Aarhus University Hospital , Aarhus , Denmark
| | - Kari Tanderup
- a Department of Oncology , Aarhus University Hospital , Aarhus , Denmark
- c Department of Medical Physics , Aarhus University Hospital , Aarhus , Denmark
| | | | - Ludvig Paul Muren
- a Department of Oncology , Aarhus University Hospital , Aarhus , Denmark
- c Department of Medical Physics , Aarhus University Hospital , Aarhus , Denmark
| |
Collapse
|
23
|
Martin S, Brophy M, Palma D, Louie AV, Yu E, Yaremko B, Ahmad B, Barron JL, Beauchemin SS, Rodrigues G, Gaede S. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging. Phys Med Biol 2015; 60:1497-518. [DOI: 10.1088/0031-9155/60/4/1497] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Josipovic M, Aznar MC, Persson GF. Deep inspiration breath hold radiotherapy of lung cancer: the good, the bad and the ugly case. Acta Oncol 2014; 53:1446-8. [PMID: 24909375 DOI: 10.3109/0284186x.2014.922216] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
25
|
Muren LP, Teräs M, Knuuti J. NACP 2014 and the Turku PET symposium: the interaction between therapy and imaging. Acta Oncol 2014; 53:993-6. [PMID: 25141819 DOI: 10.3109/0284186x.2014.941073] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Ludvig P Muren
- Department of Medical Physics, Aarhus University and Aarhus University Hospital , Aarhus , Denmark
| | | | | |
Collapse
|