1
|
Kissel M, Terlizzi M, Giraud N, Alexis A, Cheve M, Vautier J, Bossi A, Morice P, Blanchard P. Prostate radiotherapy may cause fertility issues: a retrospective analysis of testicular dose following modern radiotherapy techniques. Radiat Oncol 2024; 19:101. [PMID: 39090684 PMCID: PMC11293176 DOI: 10.1186/s13014-024-02498-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 07/26/2024] [Indexed: 08/04/2024] Open
Abstract
BACKGROUND Prostate cancer in younger men is rare but not exceptional. Radiotherapy is a cornerstone of prostate cancer treatment and yet, its impact on fertility is scarcely reported in literature. Given the radiosensitivity of testicular tissue, this study aimed to determine the testicular dose using modern radiotherapy techniques for definitive prostate irradiation. METHODS One hundred radiotherapy plans were reviewed. Testicles were contoured retrospectively without dosimetric optimization on testicles. RESULTS The median testicular dose was 0.58 Gy: 0.18 Gy in stereotactic plans, 0.62 Gy in Volumetric Modulated Arc Therapy plans and 1.50 Gy in Tomotherapy plans (p < 0.001). Pelvic nodal irradiation increased the median testicular dose to 1.18 Gy versus 0.26 Gy without nodal irradiation (p < 0.001). Weight and BMI were inversely associated with testicular dose (p < 0.005). 65% of patients reached the theoretical dose threshold for transient azoospermia, and 10% received more than 2 Gy, likely causing definitive azoospermia. CONCLUSION Despite being probably lower than doses from older techniques, the testicular dose delivered with modern prostate radiotherapy is not negligible and is often underestimated because the contribution of daily repositioning imaging is not taken into account and most Treatment Planning Systems underestimate the out of field dose. Radiation oncologists should consider the impact on fertility and gonadal endocrine function, counseling men on sperm preservation if they wish to maintain fertility. TRIAL REGISTRATION retrospectively registered.
Collapse
Affiliation(s)
- M Kissel
- Radiotherapy Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France.
- Radiation Therapy Department, Institut Curie, 26 rue d'Ulm, 75005, Paris, France.
| | - M Terlizzi
- Radiotherapy Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| | - N Giraud
- Radiotherapy Department, CHU Bordeaux, Avenue de Magellan, 33604, Pessac, France
| | - A Alexis
- Radiophysics Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| | - M Cheve
- Radiophysics Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| | - J Vautier
- Radiophysics Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| | - A Bossi
- Radiotherapy Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| | - P Morice
- Gynecologic Surgery Department, Gustave Roussy, Villejuif, France
| | - P Blanchard
- Radiotherapy Department, Gustave Roussy, 114 rue Edouard Vaillant, 94800, Villejuif, France
| |
Collapse
|
2
|
Østergaard DE, Bryce-Atkinson A, Skaarup M, Smulders B, Davies LSC, Whitfield G, Janssens GO, Hjalgrim LL, Richter IV, van Herk M, Aznar M, Vestmø Maraldo M. Paediatric CBCT protocols for image-guided radiotherapy; outcome of a survey across SIOP Europe affiliated countries and literature review. Radiother Oncol 2024; 190:109963. [PMID: 38406888 DOI: 10.1016/j.radonc.2023.109963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Revised: 10/17/2023] [Accepted: 10/20/2023] [Indexed: 02/27/2024]
Abstract
BACKGROUND Implementation of daily cone-beam CT (CBCT) into clinical practice in paediatric image-guided radiotherapy (IGRT) lags behind compared to adults. Surveys report wide variation in practice for paediatric IGRT and technical information remains unreported. In this study we report on technical settings from applied paediatric CBCT protocols and review the literature for paediatric CBCT protocols. METHODS From September to October 2022, a survey was conducted among 246 SIOPE-affiliated centres across 35 countries. The survey consisted of 3 parts: 1) baseline information; technical CBCT exposure settings and patient set-up procedure for 2) brain/head, and 3) abdomen. Descriptive statistics was used to summarise current practice. The literature was reviewed systematically with two reviewers obtaining consensus RESULTS: The literature search revealed 22 papers concerning paediatric CBCT protocols. Seven papers focused on dose-optimisation. Responses from 50/246 centres in 25/35 countries were collected: 44/50 treated with photons and 10/50 with protons. In total, 48 brain/head and 53 abdominal protocols were reported. 42/50 centres used kV-CBCT for brain/head and 35/50 for abdomen; daily CBCT was used for brain/head = 28/48 (58%) and abdomen = 33/53 62%. Greater consistency was seen in brain/head protocols (dose range 0.32 - 67.7 mGy) compared to abdominal (dose range 0.27 - 119.7 mGy). CONCLUSION Although daily CBCT is now widely used in paediatric IGRT, our survey demonstrates a wide range of technical settings, suggesting an unmet need to optimise paediatric IGRT protocols. This is in accordance with the literature. However, there are only few paediatric optimisation studies suggesting that dose reduction is possible while maintaining image quality.
Collapse
Affiliation(s)
- Daniella Elisabet Østergaard
- Section of Radiotherapy, Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Copenhagen, Denmark; Faculty of Health and Medical Sciences, Copenhagen University, Copenhagen, Denmark.
| | - Abigail Bryce-Atkinson
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Mikkel Skaarup
- Section of Radiotherapy, Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Copenhagen, Denmark
| | - Bob Smulders
- Section of Radiotherapy, Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Copenhagen, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
| | | | - Gillian Whitfield
- Manchester Academic Health Science Centre, The Christie NHS Foundation Trust, Manchester, UK; The Children's Brain Tumour Research Network, The University of Manchester, Royal Manchester Children's Hospital, Manchester, UK
| | - Geert O Janssens
- Department of Radiation Oncology, University Medical Center Utrecht, Utrecht, the Netherlands; Princess Máxima Center for Pediatric Oncology, Utrecht, the Netherlands
| | - Lisa Lyngsie Hjalgrim
- Department of Paediatrics and Adolescent Medicine, Copenhagen University Hospital, Copenhagen, Denmark
| | - Ivan Vogelius Richter
- Section of Radiotherapy, Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Copenhagen, Denmark; Faculty of Health and Medical Sciences, Copenhagen University, Copenhagen, Denmark
| | - Marcel van Herk
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Marianne Aznar
- Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Maja Vestmø Maraldo
- Section of Radiotherapy, Department of Oncology, Centre for Cancer and Organ Diseases, Copenhagen University Hospital, Copenhagen, Denmark
| |
Collapse
|
3
|
Cumur C, Fujibuchi T, Arakawa H, Hamada K. Dose estimation for cone-beam computed tomography in image-guided radiation therapy for pelvic cancer using adult mesh-type reference computational phantoms. Radiol Phys Technol 2023; 16:203-211. [PMID: 36877400 DOI: 10.1007/s12194-023-00708-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 02/24/2023] [Accepted: 02/24/2023] [Indexed: 03/07/2023]
Abstract
The use of cone-beam computed tomography (CBCT) is expanding owing to its installation in linear accelerators for radiation therapy, and the imaging dose induced by this system has become the center of attention. Here, the dose to patients caused by the CBCT imager was investigated. Organ doses and effective doses for male and female mesh-type reference computational phantoms (MRCPs) and pelvis CBCT mode, routinely used for pelvic irradiation, were estimated using the Particle and Heavy Ion Transport Code System. The simulation results were confirmed based on the point-dose measurements. The estimated organ doses for male MRCPs with/without raised arms and for female MRCPs with/without raised arms were 0.00286-35.6 mGy, 0.00286-35.1 mGy, 0.00933-39.5 mGy, and 0.00931-39.0 mGy, respectively. The anticipated effective doses for male MRCPs with/without raised arms and female MRCPs with/without raised arms irradiated by pelvis CBCT mode were 4.25 mSv, 4.16 mSv, 7.66 mSv, and 7.48 mSv, respectively. The results of this study will be useful for patients who undergo image-guided radiotherapy with CBCT. However, because this study only covered one type of cancer with one type of imager, and image quality was not considered, more studies should be conducted to estimate the radiation dose from imaging devices in radiation therapy.
Collapse
Affiliation(s)
- Ceyda Cumur
- Graduate School of Medical Sciences, Division of Medical Quantum Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan.
| | - Toshioh Fujibuchi
- Faculty of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Hiroyuki Arakawa
- Faculty of Medical Sciences, Kyushu University, 3-1-1, Maidashi, Higashi-Ku, Fukuoka, 812-8582, Japan
| | - Keisuke Hamada
- Department of Radiological Technology, National Hospital Organization Kyushu Cancer Center, 3-1-1, Notame Minami-Ku, Fukuoka, 811-1395, Japan
| |
Collapse
|
4
|
Dose assessment for daily cone-beam CT in lung radiotherapy patients and its combination with treatment planning. Phys Eng Sci Med 2022; 45:231-237. [PMID: 35076869 DOI: 10.1007/s13246-022-01105-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 01/19/2022] [Indexed: 10/19/2022]
Abstract
With the increased use of X-ray imaging for patient alignment in external beam radiation therapy, particularly with cone-beam computed tomography (CBCT), the additional dose received by patients has become of greater consideration. In this study, we analysed the radiation dose from CBCT for clinical lung radiotherapy and assessed its relative contribution when combined with radiation treatment planning for a variety of lung radiotherapy techniques. The Monte Carlo simulation program ImpactMC was used to calculate the 3D dose delivered by a Varian TrueBeam linear accelerator to patients undergoing thorax CBCT imaging. The concomitant dose was calculated by simulating the daily CBCT irradiation of ten lung cancer patients. Each case was planned with a total dose of 50-60 Gy to the target lesion in 25-30 fractions using the 3DCRT or IMRT plan and retrospectively planned using VMAT. For each clinical case, the calculated CBCT dose was summed with the planned dose, and the dose to lungs, heart, and spinal cord were analysed according to conventional dose conformity metrics. Our results indicate greater variations in dose to the heart, lungs, and spinal cord based on planning technique, (3DCRT, IMRT, VMAT) than from the inclusion of daily cone-beam imaging doses over 25-30 fractions. The average doses from CBCT imaging per fraction to the lungs, heart and spinal cord were 0.52 ± 0.10, 0.49 ± 0.15 and 0.39 ± 0.08 cGy, respectively. Lung dose variations were related to the patient's size and body composition. Over a treatment course, this may result in an additional mean absorbed dose of 0.15-0.2 Gy. For lung V5, the imaging dose resulted in an average increase of ~ 0.6% of the total volume receiving 5 Gy. The increase in V20 was more dependent on the planning technique, with 3DCRT increasing by 0.11 ± 0.09% with imaging and IMRT and VMAT increasing by 0.17 ± 0.05% and 0.2 ± 0.06%, respectively. In this study, we assessed the concomitant dose for daily CBCT lung cancer patients undergoing radiotherapy. The additional radiation dose to the normal lungs from daily CBCT was found to range from 0.15 to 0.2 Gy when the patient was treated with 25-30 fractions. Consideration of potential variation in relative biological effectiveness between kilovoltage imaging and megavoltage treatment dose was outside the scope of this study. Regardless of this, our results show that the assessment of imaging dose can be incorporated into the treatment planning process and the relative effect on overall dose distribution was small compared to the difference among planning techniques.
Collapse
|
5
|
Nazir S, Bert J, Fayad H, Visvikis D. Surface imaging for real-time patient positioning in external radiation therapy. Med Phys 2021; 48:8037-8044. [PMID: 34669989 DOI: 10.1002/mp.15300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 09/20/2021] [Accepted: 10/11/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In the last few years, there has been a growing interest in surface imaging for patient positioning in external radiation therapy. The aim of this study is to evaluate the accuracy of daily patient positioning using the Azure Kinect surface imaging. METHODS A total of 50 fractions in 10 patients including lung, pelvic, and head and neck tumors were analyzed in real time. A rigid registration algorithm, based on the iterative closest point (ICP) approach, is employed to estimate the patient position in 6 degrees of freedom (DOF). This position is compared to the reference values obtained by the radiograph imaging. The mean setup error and its standard deviation were calculated for all measured fractions. RESULTS The positioning error showed 1.1 ± 1.1 mm in lateral, 1.8 ± 2.1 mm in longitudinal, and 0.8 ± 1.1 mm in vertical, and 0.3°± 0.4° in yaw, 0.2°± 0.2° in pitch, and 0.2°± 0.2° in roll directions. The larger setup error occurred in pelvic regions. CONCLUSION We have evaluated in a radiotherapy set-up considering different patient anatomical locations, a depth measurement based surface imaging solution for patient positioning considering the 6 DOF couch motion. We showed that the proposed solution allows an accurate patient positioning without the need for patient markings or the use of additional radiation dose.
Collapse
Affiliation(s)
- Souha Nazir
- INSERM, UMR1101, LaTIM, University of Brest, Brest, France
| | - Julien Bert
- INSERM, UMR1101, LaTIM, University of Brest, Brest, France
| | - Hadi Fayad
- Hamad Medical Corporation OHS, PET/CT Center, Doha, Qatar
| | | |
Collapse
|
6
|
Ordóñez-Sanz C, Cowen M, Shiravand N, MacDougall ND. CBCT imaging: a simple approach for optimising and evaluating concomitant imaging doses, based on patient-specific attenuation, during radiotherapy pelvis treatment. Br J Radiol 2021; 94:20210068. [PMID: 34282947 PMCID: PMC8523193 DOI: 10.1259/bjr.20210068] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objectives: A simple, robust method, for optimising cone-beam CT (CBCT) dose and image quality for pelvis treatment, based on patient-specific attenuation. Methods: Methods were investigated for grouping patients into four imaging categories (small [S], medium [M], large [L], extra large [XL]), based on planning-CT CTDIvol, and phantoms constructed to represent each group. CBCTs with varying kV, mA and ms honed in on the best settings, with a bladder noise of 25 HU. A patient pilot study clinically verified the new imaging settings. Results: The planning CTDIvol is a reliable method for grouping patients. Phantom measurements from the S, M and L groups show doses significantly reduced (19–83% reduction), whilst the XL group required an increase of 39%. Phantom TLD measurements showed the number of scans needed to increase rectal organ at risk (OAR) dose by 1 Gy was 143 (S group) and 50 (M group). Images were qualitatively assessed as sufficient by clinicians. Conclusion: Patient-specific CBCT modes are in use clinically with dose reductions across all modes except Pelvis XL, keeping doses ALARP and images optimal. Consideration of OAR doses controls the number of CBCTs allowed to ensure adherence to OAR tolerance. Reporting CBCT doses in “scans per Gray” allows clinicians to make informed decisions regarding the imaging schedule and concomitant doses. Advances in knowledge: Patient grouping at planning CT, using CTDIvol, allows for CBCT imaging protocols to be selected based on patient specific attenuation. Reporting OAR doses in terms of “scans per Gray” allows translation of imaging dose risk to the Oncologist.
Collapse
Affiliation(s)
| | - Mark Cowen
- North West Anglia NHS Foundation Trust, England, UK
| | - Neda Shiravand
- Radiotherapy Physics, St Bartholomew's Hospital, London, UK
| | - Niall D MacDougall
- Radiotherapy Physics, St Bartholomew's Hospital, London, UK.,Barts Cancer Institute, Queen Mary University of London, London, UK
| |
Collapse
|
7
|
Ueno H, Matsubara K, Takemura A, Hizume M, Bou S. Evaluation of the relationship between phantom position and computed tomography dose index in cone beam computed tomography when assuming breast irradiation. J Appl Clin Med Phys 2021; 22:262-267. [PMID: 34048143 PMCID: PMC8200449 DOI: 10.1002/acm2.13282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 03/21/2021] [Accepted: 04/23/2021] [Indexed: 11/21/2022] Open
Abstract
This study aims to investigate the influence of the phantom position on weighted computed tomography dose index (CTDIw ) in cone beam computed tomography (CBCT) when assuming breast irradiation. Computed tomography dose index (CTDI) was measured by the x-ray volume imaging of CBCT using parameters for image-guided radiation therapy (IGRT) in right breast irradiation. The measurement points of CTDI ranged from 0 (center) to 16 cm in the right-left (RL) direction, and from 0 (center) to 7.5 cm in the anterior-posterior (AP) direction, which assumed right breast irradiation. A nonuniform change exists in the relative value of CTDIw when the phantom deviated from the isocenter of CBCT. The CTDIw was ~30% lower compared with the value at the isocenter of CBCT when the phantom deviated 7.5 and 16 cm at the AP and RL directions, respectively. This study confirmed the influence of the phantom position on the CTDI values of CBCT. The CTDI measured at the isocenter of CBCT overestimates that measured at the irradiation center of the breast.
Collapse
Affiliation(s)
- Hiroyuki Ueno
- Department of RadiologyTakaoka City HospitalTakaokaToyamaJapan
- Division of Health Sciences, Graduate School of Medical SciencesKanazawa UniversityKanazawaIshikawaJapan
| | - Kosuke Matsubara
- Division of Health Sciences, Graduate School of Medical SciencesKanazawa UniversityKanazawaIshikawaJapan
| | - Akihiro Takemura
- Division of Health Sciences, Graduate School of Medical SciencesKanazawa UniversityKanazawaIshikawaJapan
| | - Masato Hizume
- Department of RadiologyTakaoka City HospitalTakaokaToyamaJapan
| | - Sayuri Bou
- Department of RadiotherapyTakaoka City HospitalTakaokaToyamaJapan
| |
Collapse
|
8
|
Olch AJ, Alaei P. How low can you go? A CBCT dose reduction study. J Appl Clin Med Phys 2021; 22:85-89. [PMID: 33450139 PMCID: PMC7882101 DOI: 10.1002/acm2.13164] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 12/17/2020] [Accepted: 12/22/2020] [Indexed: 12/18/2022] Open
Abstract
Purpose Cone beam computed tomography (CBCT) is often used for patient setup based solely on bony anatomy. The goal of this work was to evaluate whether CBCT dose can be lowered to the level of kV image pair doses when used for bony anatomy‐based IGRT without compromising positioning accuracy. Methods An anthropomorphic phantom was CT scanned in the head, head and neck, chest, and pelvis regions and setup on the linear accelerator couch with the isocenter near the planned location. Cone beam computed tomographies were performed with the standard “full dose” protocol supplied by the linac vendor. With sequentially lowering the dose, three‐dimensional (3D) matching was performed for each without shifting the couch. The standard kV image pair protocol for each site was also used to image the phantoms. For all studies, six degrees of freedom was included in the 2D or 3D matching to the extent they could be employed. Imaging doses were determined in air at isocenter following the TG‐61 formalism. Results Cone beam computed tomography dose was reduced by 81–98% of the standard CBCT protocol to nearly that of the standard kV image pair dose for each site. Relative to the standard CBCT shift values, translational shifts were within 0.3 and 1.6 mm for all sites, for the reduced dose CBCT and kV image pair, respectively. Rotational shifts were within 0.2 degree and 0.7 degrees for all sites, for the reduced dose CBCTs and kV image pair, respectively. Conclusion For bony anatomy‐based image guidance, CBCT dose can be reduced to a value similar to that of a kV image pair with similar or better patient positioning accuracy than kV image pair alignment. Where rotations are important to correct, CBCT will be superior to orthogonal kV imaging without significantly increased imaging dose. This is especially important for image guidance for pediatric patient treatments.
Collapse
Affiliation(s)
- Arthur J Olch
- Radiation Oncology Program, Children's Hospital Los Angeles, Los Angeles, CA, USA
| | - Parham Alaei
- Department of Radiation Oncology, University of Minnesota, Minneapolis, MN, USA
| |
Collapse
|
9
|
Hua CH, Vern-Gross TZ, Hess CB, Olch AJ, Alaei P, Sathiaseelan V, Deng J, Ulin K, Laurie F, Gopalakrishnan M, Esiashvili N, Wolden SL, Krasin MJ, Merchant TE, Donaldson SS, FitzGerald TJ, Constine LS, Hodgson DC, Haas-Kogan DA, Mahajan A, Laack N, Marcus KJ, Taylor PA, Ahern VA, Followill DS, Buchsbaum JC, Breneman JC, Kalapurakal JA. Practice patterns and recommendations for pediatric image-guided radiotherapy: A Children's Oncology Group report. Pediatr Blood Cancer 2020; 67:e28629. [PMID: 32776500 PMCID: PMC7774502 DOI: 10.1002/pbc.28629] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Revised: 06/16/2020] [Accepted: 07/19/2020] [Indexed: 12/18/2022]
Abstract
This report by the Radiation Oncology Discipline of Children's Oncology Group (COG) describes the practice patterns of pediatric image-guided radiotherapy (IGRT) based on a member survey and provides practice recommendations accordingly. The survey comprised of 11 vignettes asking clinicians about their recommended treatment modalities, IGRT preferences, and frequency of in-room verification. Technical questions asked physicists about imaging protocols, dose reduction, setup correction, and adaptive therapy. In this report, the COG Radiation Oncology Discipline provides an IGRT modality/frequency decision tree and the expert guidelines for the practice of ionizing image guidance in pediatric radiotherapy patients.
Collapse
Affiliation(s)
- Chia-ho Hua
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, Tennessee
| | | | - Clayton B. Hess
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts
- Department of Radiation Oncology, Emory University, Atlanta, Georgia
| | - Arthur J. Olch
- Department of Radiation Oncology, University of Southern California and Children’s Hospital of Los Angeles, Los Angeles, California
| | - Parham Alaei
- Department of Radiation Oncology, University of Minnesota, Minneapolis, Minnesota
| | | | - Jun Deng
- Department of Therapeutic Radiology, Yale University, New Haven, Connecticut
| | - Kenneth Ulin
- Department of Radiation Oncology, University of Massachusetts, Worcester, Massachusetts
| | - Fran Laurie
- Department of Radiation Oncology, University of Massachusetts, Worcester, Massachusetts
| | | | - Natia Esiashvili
- Department of Radiation Oncology, Emory University, Atlanta, Georgia
| | - Suzanne L. Wolden
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Matthew J. Krasin
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, Tennessee
| | - Thomas E Merchant
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, Tennessee
| | - Sarah S. Donaldson
- Department of Radiation Oncology, Stanford University, Stanford, California
| | - Thomas J. FitzGerald
- Department of Radiation Oncology, University of Massachusetts, Worcester, Massachusetts
| | - Louis S. Constine
- Department of Radiation Oncology, University of Rochester, Rochester, New York
| | - David C. Hodgson
- Department of Radiation Oncology, University of Toronto, Toronto, Ontario, Canada
| | - Daphne A. Haas-Kogan
- Department of Radiation Oncology, Dana Farber Cancer Institute/Boston Children’s Hospital, Boston, Massachusetts
| | - Anita Mahajan
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota
| | - Nadia Laack
- Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota
| | - Karen J. Marcus
- Department of Radiation Oncology, Dana Farber Cancer Institute/Boston Children’s Hospital, Boston, Massachusetts
| | - Paige A Taylor
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Verity A Ahern
- Department of Radiation Oncology, Children’s Hospital at Westmead, Sydney, Australia
| | - David S. Followill
- Department of Radiation Physics, Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Jeffrey C. Buchsbaum
- Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, Maryland
| | - John C. Breneman
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, Ohio
| | - John A. Kalapurakal
- Department of Radiation Oncology, Northwestern University, Chicago, Illinois
| |
Collapse
|
10
|
Tomita T, Isobe T, Furuyama Y, Takei H, Kobayashi D, Mori Y, Terunuma T, Sato E, Yokota H, Sakae T. Evaluation of Dose Distribution and Normal Tissue Complication Probability of a Combined Dose of Cone-Beam Computed Tomography Imaging with Treatment in Prostate Intensity-Modulated Radiation Therapy. J Med Phys 2020; 45:78-87. [PMID: 32831490 PMCID: PMC7416863 DOI: 10.4103/jmp.jmp_4_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 03/02/2020] [Accepted: 03/31/2020] [Indexed: 12/03/2022] Open
Abstract
Purpose: The purpose of this study is to evaluate the effects of cone-beam computed tomography (CBCT) on dose distribution and normal tissue complication probability (NTCP) by constructing a comprehensive dose evaluation system for prostate intensity-modulated radiation therapy (IMRT). Methods: A system that could combine CBCT and treatment doses with MATLAB was constructed. Twenty patients treated with prostate IMRT were studied. A mean dose of 78 Gy was prescribed to the prostate region, excluding the rectal volume from the target volume, with margins of 4 mm to the dorsal side of the prostate and 7 mm to the entire circumference. CBCT and treatment doses were combined, and the dose distribution and the NTCP of the rectum and bladder were evaluated. Results: The radiation dose delivered to 2% and 98% of the target volume increased by 0.90 and 0.74 Gy on average, respectively, in the half-fan mode and on average 0.76 and 0.72 Gy, respectively, in the full-fan mode. The homogeneity index remained constant. The percent volume of the rectum and bladder irradiated at each dose increased slightly, with a maximum increase of <1%. The rectal NTCP increased by approximately 0.07% from 0.46% to 0.53% with the addition of a CBCT dose, while the maximum NTCP in the bladder was approximately 0.02%. Conclusions: This study demonstrated a method to evaluate a combined dose of CBCT and a treatment dose using the constructed system. The combined dose distribution revealed increases of <1% volume in the rectal and bladder doses and approximately 0.07% in the rectal NTCP.
Collapse
Affiliation(s)
- Tetsuya Tomita
- Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan.,Department of Radiology, University of Tsukuba Hospital, Ibaraki, Japan
| | - Tomonori Isobe
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | | | - Hideyuki Takei
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | - Daisuke Kobayashi
- Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan.,Department of Radiology, University of Tsukuba Hospital, Ibaraki, Japan
| | - Yutaro Mori
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | | | - Eisuke Sato
- Faculty of Health Sciences, Juntendo University, Tokyo, Japan
| | - Hiroshi Yokota
- Department of Radiology, University of Tsukuba Hospital, Ibaraki, Japan
| | - Takeji Sakae
- Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| |
Collapse
|
11
|
Liang X, Jiang Y, Zhao W, Zhang Z, Luo C, Xiong J, Yu S, Yang X, Sun J, Zhou Q, Niu T, Xie Y. Scatter correction for a clinical cone‐beam CT system using an optimized stationary beam blocker in a single scan. Med Phys 2019; 46:3165-3179. [DOI: 10.1002/mp.13568] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 04/04/2019] [Accepted: 04/25/2019] [Indexed: 12/16/2022] Open
Affiliation(s)
- Xiaokun Liang
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Yangkang Jiang
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Wei Zhao
- Department of Radiation Oncology Stanford University Stanford CA 94305USA
| | - Zhicheng Zhang
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Chen Luo
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Jing Xiong
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Shaode Yu
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
- Shenzhen Colleges of Advanced Technology University of Chinese Academy of Sciences Shenzhen Guangdong 518055China
| | - Xiaoming Yang
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Jihong Sun
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Qinxuan Zhou
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Tianye Niu
- Institute of Translational Medicine Zhejiang University Hangzhou Zhejiang 310016China
- Sir Run Run Shaw Hospital Zhejiang University School of Medicine Hangzhou Zhejiang 310016China
| | - Yaoqin Xie
- Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences Shenzhen Guangdong 518055China
| |
Collapse
|
12
|
Ding GX, Zhang Y, Ren L. Technical Note: Imaging dose resulting from optimized procedures with limited-angle intrafractional verification system during stereotactic body radiation therapy lung treatment. Med Phys 2019; 46:2709-2715. [PMID: 30937910 DOI: 10.1002/mp.13511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2018] [Revised: 01/17/2019] [Accepted: 02/15/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The limited-angle intrafractional verification (LIVE) system was developed to track tumor movement during stereotactic body radiation therapy (SBRT). However, the four-dimensional (4D) MV/kV imaging procedure results in additional radiation dose to patients. This study is to quantify imaging radiation dose from optimized MV/kV image acquisition in the LIVE system and to determine if it exceeds the American Association of Physicists in Medicine Task Group Report 180 image dose threshold. METHODS TrueBeam™ platform with a fully integrated system for image guidance was studied. Monte Carlo-simulated kV and MV beams were calibrated and then used as incident sources in an EGSnrc Monte Carlo dose calculation in a CT image-based patient model. In three representative lung SBRT treatments evaluated in this study, tumors were located in the patient's posterior left lung, mid-left lung, and right upper lung. The optimized imaging sequence comprised of arcs ranging from 2 to 7, acquired between adjacent three-dimensional (3D)/IMRT beams, with multiple simultaneous kV (125 kVp) and MV (6 MV) image projections in each arc, for different optimization scenarios. The MV imaging fields were generally confined to the treatment target while kV images were acquired with a normal open field size with a full bow-tie filter. RESULTS In a seven-arc acquisitions case (highest imaging dose scenario), the maximum kV imaging doses to 50% of the tissue volume (D50 from DVHs), for spinal cord, right lung, heart, left lung, and the target, were 0.4, 0.4, 0.6, 0.7, and 1.4 cGy, respectively. The corresponding MV imaging doses were 0.1 cGy to spinal cord, right lung, heart, and left lung, and 11 cGy to target. In contrast, the maximum radiation dose from two cases treated with two Volumetric-Modulated Arc Therapy (VMAT) fields and two-arc image acquisitions is approximately 30% of that of the seven-arc acquisition. CONCLUSIONS We have evaluated the additional radiation dose resulting from optimized LIVE system MV/kV image acquisitions in two best (least imaging dose) and one worst (highest imaging dose) lung SBRT treatment scenarios. The results show that these MV/kV imaging doses are comparable to those resulting from current imaging procedures used in Image-Guided Radiation Therapy (IGRT) and are within the dose threshold of 5% target dose as recommended by the AAPM TG-180 report.
Collapse
Affiliation(s)
- George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, USA
| | - Yawei Zhang
- Department of Radiation Oncology, Duke University, Durham, NC, USA
| | - Lei Ren
- Department of Radiation Oncology, Duke University, Durham, NC, USA.,Medical Physics Graduate Program, Duke University, Durham, NC, USA
| |
Collapse
|
13
|
Grelewicz Z, Belcher AH, Wiersma RD. Use of a laser‐guided collimation system to perform direct kilovoltage x‐ray spectra measurements on a linear accelerator onboard imager. Med Phys 2018; 45:4869-4876. [DOI: 10.1002/mp.13188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 08/09/2018] [Accepted: 08/19/2018] [Indexed: 11/09/2022] Open
Affiliation(s)
- Zachary Grelewicz
- Department of Radiation and Cellular Oncology University of Chicago Chicago IL 60637‐1470 USA
| | - Andrew H. Belcher
- Department of Radiation and Cellular Oncology University of Chicago Chicago IL 60637‐1470 USA
| | - Rodney D. Wiersma
- Department of Radiation and Cellular Oncology University of Chicago Chicago IL 60637‐1470 USA
| |
Collapse
|
14
|
Bell K, Licht N, Rübe C, Dzierma Y. Image guidance and positioning accuracy in clinical practice: influence of positioning errors and imaging dose on the real dose distribution for head and neck cancer treatment. Radiat Oncol 2018; 13:190. [PMID: 30285806 PMCID: PMC6167812 DOI: 10.1186/s13014-018-1141-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Accepted: 09/24/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Modern radiotherapy offers the possibility of highly accurate tumor treatment. To benefit from this precision at its best, regular positioning verification is necessary. By the use of image-guided radiotherapy and the application of safety margins the influence of positioning inaccuracies can be counteracted. In this study the effect of additional imaging dose by set-up verification is compared with the effect of dose smearing by positioning inaccuracies for a collective of head-and-neck cancer patients. METHODS This study is based on treatment plans of 40 head-and-neck cancer patients. To evaluate the imaging dose several image guidance scenarios with different energies, techniques and frequencies were simulated and added to the original plan. The influence of the positioning inaccuracies was assessed by the use of real applied table shifts for positioning. The isocenters were shifted back appropriately to these values to simulate that no positioning correction had been performed. For the single fractions the shifted plans were summed considering three different scenarios: The summation of only shifted plans, the consideration of the original plan for the fractions with set-up verification, and the addition of the extra imaging dose to the latter. For both effects (additional imaging dose and dose smearing), plans were analyzed and compared considering target coverage, sparing of organs at risk (OAR) and normal tissue complication probability (NTCP). RESULTS Daily verification of the patient positioning using 3D imaging with MV energies result in non-negligible high doses. kV imaging has only marginal influence on plan quality, primarily related to sparing of organs at risk, even with daily 3D imaging. For this collective, sparing of organs at risk and NTCP are worse due to potential positioning errors. CONCLUSION Regular set-up verification is essential for precise radiation treatment. Relating to the additional dose, the use of kV modalities is uncritical for any frequency and technique. Dose smearing due to positioning errors for this collective mainly resulted in a decrease of OAR sparing. Target coverage also suffered from the positioning inaccuracies, especially for individual patients. Taking into account both examined effects the relevance of an extensive IGRT is clearly present, even at the expense of additional imaging dose and time expenditure.
Collapse
Affiliation(s)
- Katharina Bell
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5/Saar, D-66421 Homburg, Germany
| | - Norbert Licht
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5/Saar, D-66421 Homburg, Germany
| | - Christian Rübe
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5/Saar, D-66421 Homburg, Germany
| | - Yvonne Dzierma
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5/Saar, D-66421 Homburg, Germany
| |
Collapse
|
15
|
Jin F, Luo HL, Zhou J, He YN, Liu XF, Zhong MS, Yang H, Li C, Li QC, Huang X, Tian XM, Qiu D, He GL, Yin L, Wang Y. Cancer risk assessment in modern radiotherapy workflow with medical big data. Cancer Manag Res 2018; 10:1665-1675. [PMID: 29970965 PMCID: PMC6021004 DOI: 10.2147/cmar.s164980] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Modern radiotherapy (RT) is being enriched by big digital data and intensive technology. Multimodality image registration, intelligence-guided planning, real-time tracking, image-guided RT (IGRT), and automatic follow-up surveys are the products of the digital era. Enormous digital data are created in the process of treatment, including benefits and risks. Generally, decision making in RT tries to balance these two aspects, which is based on the archival and retrieving of data from various platforms. However, modern risk-based analysis shows that many errors that occur in radiation oncology are due to failures in workflow. These errors can lead to imbalance between benefits and risks. In addition, the exact mechanism and dose-response relationship for radiation-induced malignancy are not well understood. The cancer risk in modern RT workflow continues to be a problem. Therefore, in this review, we develop risk assessments based on our current knowledge of IGRT and provide strategies for cancer risk reduction. Artificial intelligence (AI) such as machine learning is also discussed because big data are transforming RT via AI.
Collapse
Affiliation(s)
- Fu Jin
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Huan-Li Luo
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Juan Zhou
- Forensic Identification Center, College of Criminal Investigation, Southwest University of Political Science and Law, Chongqing, People’s Republic of China
| | - Ya-Nan He
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Xian-Feng Liu
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Ming-Song Zhong
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Han Yang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Chao Li
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Qi-Cheng Li
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Xia Huang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Xiu-Mei Tian
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Da Qiu
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Guang-Lei He
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Li Yin
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| | - Ying Wang
- Department of Radiation Oncology, Chongqing University Cancer Hospital, Chongqing Cancer Institute, Chongqing Cancer Hospital, Chongqing, People’s Republic of China
| |
Collapse
|
16
|
Ding GX, Alaei P, Curran B, Flynn R, Gossman M, Mackie TR, Miften M, Morin R, Xu XG, Zhu TC. Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180. Med Phys 2018; 45:e84-e99. [PMID: 29468678 DOI: 10.1002/mp.12824] [Citation(s) in RCA: 75] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 01/10/2018] [Accepted: 01/10/2018] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND With radiotherapy having entered the era of image guidance, or image-guided radiation therapy (IGRT), imaging procedures are routinely performed for patient positioning and target localization. The imaging dose delivered may result in excessive dose to sensitive organs and potentially increase the chance of secondary cancers and, therefore, needs to be managed. AIMS This task group was charged with: a) providing an overview on imaging dose, including megavoltage electronic portal imaging (MV EPI), kilovoltage digital radiography (kV DR), Tomotherapy MV-CT, megavoltage cone-beam CT (MV-CBCT) and kilovoltage cone-beam CT (kV-CBCT), and b) providing general guidelines for commissioning dose calculation methods and managing imaging dose to patients. MATERIALS & METHODS We briefly review the dose to radiotherapy (RT) patients resulting from different image guidance procedures and list typical organ doses resulting from MV and kV image acquisition procedures. RESULTS We provide recommendations for managing the imaging dose, including different methods for its calculation, and techniques for reducing it. The recommended threshold beyond which imaging dose should be considered in the treatment planning process is 5% of the therapeutic target dose. DISCUSSION Although the imaging dose resulting from current kV acquisition procedures is generally below this threshold, the ALARA principle should always be applied in practice. Medical physicists should make radiation oncologists aware of the imaging doses delivered to patients under their care. CONCLUSION Balancing ALARA with the requirement for effective target localization requires that imaging dose be managed based on the consideration of weighing risks and benefits to the patient.
Collapse
Affiliation(s)
- George X Ding
- Department of Radiation Oncology, Vanderbilt University School of Medicine, Nashville, TN, 37232, USA
| | - Parham Alaei
- University of Minnesota, Minneapolis, MN, 55455, USA
| | - Bruce Curran
- Virginia Commonwealth University, Richmond, VA, 23284, USA
| | - Ryan Flynn
- University of Iowa, Iowa City, IA, 52242, USA
| | | | | | | | | | - X George Xu
- Rensselaer Polytechnic Institute, Troy, NY, 12180, USA
| | - Timothy C Zhu
- University of Pennsylvania, Philadelphia, PA, 19104, USA
| |
Collapse
|
17
|
Estabrook NC, Corn JB, Ewing MM, Cardenes HR, Das IJ. Dosimetric impact of gastrointestinal air column in radiation treatment of pancreatic cancer. Br J Radiol 2017; 91:20170512. [PMID: 29166133 DOI: 10.1259/bjr.20170512] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
OBJECTIVE Dosimetric evaluation of air column in gastrointestinal (GI) structures in intensity modulated radiation therapy (IMRT) of pancreatic cancer. METHODS Nine sequential patients were retrospectively chosen for dosimetric analysis of air column in the GI apparatus in pancreatic cancer using cone beam CT (CBCT). The four-dimensional CT (4DCT) was used for target and organs at risk (OARs) and non-coplanar IMRT was used for treatment. Once a week, these patients underwent CBCT for air filling, isocentre verification and dose calculations retrospectively. RESULTS Abdominal air column variation was as great as ±80% between weekly CBCT and 4DCT. Even with such a large air column in the treatment path for pancreatic cancer, changes in anteroposterior dimension were minimal (2.8%). Using IMRT, variations in air column did not correlate dosimetrically with large changes in target volume. An average dosimetric deviation of mere -3.3% and a maximum of -5.5% was observed. CONCLUSION CBCT revealed large air column in GI structures; however, its impact is minimal for target coverage. Because of the inherent advantage of segmentation in IMRT, where only a small fraction of a given beam passes through the air column, this technique might have an advantage over 3DCRT in treating upper GI malignancies where the daily air column can have significant impact. Advances in knowledge: Radiation treatment of pancreatic cancer has significant challenges due to positioning, imaging of soft tissues and variability of air column in bowels. The dosimetric impact of variable air column is retrospectively studied using CBCT. Even though, the volume of air column changes by ± 80%, its dosimetric impact in IMRT is minimum.
Collapse
Affiliation(s)
- Neil C Estabrook
- 1 Indiana University Health Arnett Cancer Care , Lafayette, IN , USA
| | - Jonathan B Corn
- 1 Indiana University Health Arnett Cancer Care , Lafayette, IN , USA
| | - Marvene M Ewing
- 2 Department of Radiation Oncology, Indiana University School of Medicine , Indianapolis, IN , USA
| | - Higinia R Cardenes
- 3 The Arnold Center for Radiation Oncology, New York Presbyterian Queens Weill Cornell Medicine , New York, NY , USA
| | - Indra J Das
- 4 Department of Radiation Oncology, New York University Langone Medical Center , New York, NY , USA
| |
Collapse
|
18
|
Bell K, Heitfeld M, Licht N, Rübe C, Dzierma Y. Influence of daily imaging on plan quality and normal tissue toxicity for prostate cancer radiotherapy. Radiat Oncol 2017; 12:7. [PMID: 28069053 PMCID: PMC5223448 DOI: 10.1186/s13014-016-0757-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Accepted: 12/28/2016] [Indexed: 11/10/2022] Open
Abstract
Background Modern radiotherapy offers various possibilities for image guided verification of patient positioning. Different clinically relevant IGRT (image guided radiotherapy) scenarios were considered with regard to their influence on dosimetric plan quality and normal tissue complication probability (NTCP). Methods This study is based on treatment plans of 50 prostate patients. We evaluate the clinically performed IGRT and simulate the influence of different daily IGRT scenarios on plan quality. Imaging doses of planar and cone-beam-CT (CBCT) images for three different energies (6 MV, 1 MV and 121 kV) were added to the treatment plans. The plan quality of the different scenarios was assessed by a visual inspection of the dose distribution and dose-volume-histogram (DVH) and a statistical analysis of DVH criteria. In addition, an assessment of the normal tissue complication probability was performed. Results Daily 1MV-CBCTs result in undesirable high dose regions in the target volume. The DVH shows that the scenarios with actual imaging performed, daily kV-CBCT and daily 6MV imaging (1x CBCT, 4x planar images per week) do not differ exceedingly from the original plan; especially imaging with daily kV-CBCT has little influence to the sparing of organs at risk. In contrast, daily 1MV- CBCT entails an additional dose of up to two fraction doses. Due to the additional dose amount some DVH constraints for plan acceptability could no longer be satisfied, especially for the daily 1MV-CBCT scenario. This scenario also shows increased NTCP for the rectum. Conclusion Daily kV-CBCT has negligible influence on plan quality and is commendable for the clinical routine. If no kV-modality is available, a daily IGRT scenario with one CBCT per week and planar axial images on the other days should be preferred over daily MV-CBCT.
Collapse
Affiliation(s)
- Katharina Bell
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5, D-66421, Homburg/Saar, Germany.
| | - Marina Heitfeld
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5, D-66421, Homburg/Saar, Germany
| | - Norbert Licht
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5, D-66421, Homburg/Saar, Germany
| | - Christian Rübe
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5, D-66421, Homburg/Saar, Germany
| | - Yvonne Dzierma
- Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. Geb. 6.5, D-66421, Homburg/Saar, Germany
| |
Collapse
|
19
|
Duffy O, Forde E, Leech M. The dilemma of parotid gland and pharyngeal constrictor muscles preservation—Is daily online image guidance required? A dosimetric analysis. Med Dosim 2017; 42:24-30. [PMID: 28126473 DOI: 10.1016/j.meddos.2016.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Revised: 10/19/2016] [Accepted: 10/26/2016] [Indexed: 10/20/2022]
|
20
|
Alaei P, Spezi E. Imaging dose from cone beam computed tomography in radiation therapy. Phys Med 2015; 31:647-58. [PMID: 26148865 DOI: 10.1016/j.ejmp.2015.06.003] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2015] [Revised: 05/29/2015] [Accepted: 06/05/2015] [Indexed: 12/26/2022] Open
Abstract
Imaging dose in radiation therapy has traditionally been ignored due to its low magnitude and frequency in comparison to therapeutic dose used to treat patients. The advent of modern, volumetric, imaging modalities, often as an integral part of linear accelerators, has facilitated the implementation of image-guided radiation therapy (IGRT), which is often accomplished by daily imaging of patients. Daily imaging results in additional dose delivered to patient that warrants new attention be given to imaging dose. This review summarizes the imaging dose delivered to patients as the result of cone beam computed tomography (CBCT) imaging performed in radiation therapy using current methods and equipment. This review also summarizes methods to calculate the imaging dose, including the use of Monte Carlo (MC) and treatment planning systems (TPS). Peripheral dose from CBCT imaging, dose reduction methods, the use of effective dose in describing imaging dose, and the measurement of CT dose index (CTDI) in CBCT systems are also reviewed.
Collapse
Affiliation(s)
| | - Emiliano Spezi
- School of Engineering, Cardiff University, Cardiff, Wales, UK; Velindre Cancer Centre, Cardiff, Wales, UK
| |
Collapse
|