1
|
Wilson T, Szpak P. Acidification does not alter the stable isotope composition of bone collagen. PeerJ 2022; 10:e13593. [PMID: 35722259 PMCID: PMC9205305 DOI: 10.7717/peerj.13593] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 05/25/2022] [Indexed: 01/17/2023] Open
Abstract
In this study, we compared the elemental and isotopic composition of modern and ancient bone samples pre-treated using different demineralization agents with acidic and neutral pH. The purpose of our research was to examine if demineralization using a mineral acid such as hydrochloric acid (HCl) significantly alters the δ 15N and δ 13C values of bone collagen. Evidence from the elemental and amino acid composition of the samples were incorporated alongside isotopic compositions to provide a holistic view of the effect of demineralization agents on the composition of bone collagen. The stable isotope compositions of collagen extracts were also compared against equivalent whole bone samples to assess whether whole bone has a stable isotope composition that is comparable to collagen demineralized with a neutral agent. Our results demonstrate that bone demineralization using either ethylenediaminetetraacetic acid (EDTA) or HCl yields collagen extracts with stable isotope compositions that are not significantly different, indicating that mineral acid does not alter δ 15N and δ 13C values of bone collagen. The results comparing whole bone and extracted collagen stable isotope compositions indicate that whole bone cannot be used as an effective replacement for bone collagen due to the significantly different stable isotope compositions between these sample materials. In ecological and archaeological studies performing stable isotope analysis on bone, sample pre-treatment to isolate collagen is a necessity to obtain the most reliable and reproducible isotopic measurements.
Collapse
Affiliation(s)
- Tess Wilson
- Department of Anthropology, Trent University, Peterborough, Ontario, Canada,Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Paul Szpak
- Department of Anthropology, Trent University, Peterborough, Ontario, Canada
| |
Collapse
|
2
|
Creecy A, Smith C, Wallace JM. Dietary supplements do not improve bone morphology or mechanical properties in young female C57BL/6 mice. Sci Rep 2022; 12:9804. [PMID: 35697787 PMCID: PMC9192719 DOI: 10.1038/s41598-022-14068-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Accepted: 05/31/2022] [Indexed: 11/13/2022] Open
Abstract
Bone is a hierarchical material formed by an organic extracellular matrix and mineral where each component and their physical relationship with each other contribute to fracture resistance. Bone quality can be affected by nutrition, and dietary supplements that are marketed to improve overall health may improve the fracture resistance of bone. To test this, 11 week old female C57BL/6 mice were fed either collagen, chondroitin sulfate, glucosamine sulfate, or fish oil 5 times a week for 8 weeks. Femurs, tibiae, and vertebrae were scanned with micro-computed tomography and then mechanically tested. Glucosamine and fish oil lowered elastic modulus, but did not alter the overall strength of the femur. There were no differences in bone mechanics of the tibiae or vertebrae. Overall, the data suggest that dietary supplements did little to improve bone quality in young, healthy mice. These supplements may be more effective in diseased or aged mice.
Collapse
Affiliation(s)
- Amy Creecy
- Department of Biomedical Engineering, Indiana University-Purdue University Indianapolis, SL 220B, 723 W. Michigan St., Indianapolis, IN, 46202, USA.,Department of Anatomy, Cell Biology, and Physiology, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Collier Smith
- Department of Biomedical Engineering, Indiana University-Purdue University Indianapolis, SL 220B, 723 W. Michigan St., Indianapolis, IN, 46202, USA
| | - Joseph M Wallace
- Department of Biomedical Engineering, Indiana University-Purdue University Indianapolis, SL 220B, 723 W. Michigan St., Indianapolis, IN, 46202, USA.
| |
Collapse
|
3
|
Biswas PP, Turner-Walker G, Rathod J, Liang B, Wang CC, Lee YC, Sheu HS. Sustainable phosphorus management in soil using bone apatite. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 305:114344. [PMID: 34953223 DOI: 10.1016/j.jenvman.2021.114344] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 12/13/2021] [Accepted: 12/17/2021] [Indexed: 06/14/2023]
Abstract
Soil fertility and phosphorus management by bone apatite amendment are receiving increasing attention, yet further research is needed to integrate the physicochemical and mineralogical transformation of bone apatite and their impact on the supply and storage of phosphorus in soil. This study has examined bone transformation in the field over a span of 10-years using a set of synchrotron-based microscopic and spectroscopic techniques. Transmission X-ray microscopy (TXM) observations reveal the in-situ deterioration of bone osteocyte-canaliculi system and sub-micron microbial tunneling within a year. Extensive organic decomposition, secondary mineral formation and re-mineralization of apatite are evident from the 3rd year. The relative ratio of (v1 + v3) PO43- to v3 CO32- and to amide I increase, and the v3c PO43- peak exhibits a blue-shift in less than 3 years. The carbonate substitution of bone hydroxyapatite (HAp) to AB-type CHAp, and phosphate crystallographic rearrangement become apparent after 10 years' aging. The overall CO32- peak absorbance increases over time, contributing to a higher acid susceptibility in the aged bone. The X-ray Photoelectron Spectroscopy (XPS) binding energies for Ca (2p), P (2p) and O (1s) exhibit a red-shift after 1 year because of organo-mineral interplay and a blue-shift starting from the 3rd year as a result of the de-coupling of mineral and organic components. Nutrient supply to soil occurs within months via organo-mineral decoupling and demineralization. More phosphorus has been released from the bones and enriched in the associated and adjacent soils over time. Lab incubation studies reveal prominent secondary mineral formation via re-precipitation at a pH similar to that in soil, which are highly amorphous and carbonate substituted and prone to further dissolution in an acidic environment. Our high-resolution observations reveal a stage-dependent microbial decomposition, phosphorus dissolution and immobilization via secondary mineral formation over time. The active cycling of phosphorus within the bone and its interplay with adjacent soil account for a sustainable supply and storage of phosphorus nutrients.
Collapse
Affiliation(s)
| | - Gordon Turner-Walker
- Department of Cultural Heritage Conservation, National Yunlin University of Science & Technology, Douliu, Taiwan
| | - Jagat Rathod
- Department of Earth Sciences, National Cheng Kung University, Tainan, Taiwan
| | - Biqing Liang
- Department of Earth Sciences, National Cheng Kung University, Tainan, Taiwan.
| | | | - Yao-Chang Lee
- National Synchrotron Radiation Center, Hsinchu, Taiwan; Department of Optics and Photonics, National Central University, Chung-Li, Taiwan; Department of Chemistry, National Tsing Hua University, Hsinchu, Taiwan
| | | |
Collapse
|
4
|
Thangadurai S, Brumfeld V, Milgram J, Li L, Shahar R. Osteodentin in the Atlantic wolffish (Anarhichas lupus): Dentin or bone? J Morphol 2021; 283:219-235. [PMID: 34910318 DOI: 10.1002/jmor.21438] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 12/04/2021] [Accepted: 12/11/2021] [Indexed: 11/09/2022]
Abstract
The teeth of actinopterygian fish, like those of mammals, consist of a thin outer hyper-mineralized layer (enamel or enameloid) that surrounds a core of dentin. While all mammalian species have a single type of dentin (called orthodentin), various dentin types have been reported in the teeth of actinopterygian fish. The most common type of actinopterygian fish dentin is orthodentin. However, the second most common type of actinopterygian fish dentin, called osteodentin, found in several teleost species and in many Selachians, is structurally radically different from orthodentin. Osteodentin, comprising denteons and inter-denteonal matrix, is characterized by an appearance that is similar to mammalian osteonal bone, however, it lacks cells and a lacuno-canalicular system. The current consensus is that although osteodentin is morphologically different from orthodentin, it is a true dentinal material, the product of odontoblast cells. We present the results of a study of osteodentin found in the teeth of the Atlantic wolffish, Anarhichas lupus. Using a variety of microscopy techniques, high-resolution microCT scans, and micro-indentation we describe the three-dimensional structure of both its components (denteons and inter-denteonal matrix), as well as their mineral density distribution and mechanical properties, at several length-scales. We show that wolffish osteodentin is remarkably similar to the anosteocytic bone of the swords of several swordfish species. We also describe the three-dimensional network of canals found in mature osteodentin. The high density of these canals in a metabolically inactive, acellular tissue casts doubt upon the accepted paradigm, that the canals house a vascular network.
Collapse
Affiliation(s)
- Senthil Thangadurai
- Koret School of Veterinary Medicine, Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot, Israel
| | - Vlad Brumfeld
- Department of Chemical Research Support, Weizmann Institute of Science, Rehovot, Israel
| | - Joshua Milgram
- Koret School of Veterinary Medicine, Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot, Israel
| | - Ling Li
- Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Virginia, USA
| | - Ron Shahar
- Koret School of Veterinary Medicine, Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Rehovot, Israel
| |
Collapse
|
5
|
Long EB, Barak MM, Frost VJ. The effect of Staphylococcus aureus exposure on white-tailed deer trabecular bone stiffness and yield. J Mech Behav Biomed Mater 2021; 126:105000. [PMID: 34894499 DOI: 10.1016/j.jmbbm.2021.105000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Revised: 11/08/2021] [Accepted: 11/24/2021] [Indexed: 10/19/2022]
Abstract
With a growing number of osteomyelitis diagnoses, many of which are linked to Staphylococcus aureus (S. aureus), it is imperative to understand the pathology of S. aureus in relation to bone to provide better diagnostics and patient care. While the cellular mechanisms of S. aureus and osteomyelitis have been studied, little information exists on the biomechanical effects of such infections. The aim of this study was to determine the effect of S. aureus exposure on the stiffness and yield of trabecular bone tissue. S. aureus-ATCC-12600, a confirmed biofilm producer, along with one hundred and three trabecular cubes (5 × 5 × 5 mm) from the proximal tibiae of Odocoileus virginianus (white-tailed deer) were used in this experiment. Bone cubes were disinfected and then swabbed to confirm no residual living microbes or endospore contamination before inoculation with S. aureus (test group) or sterile nutrient broth (control group) for 72 h. All cubes were then tested in compression until yield using an Instron 5942 Single-Column machine. Structural stiffness (N/mm) and yield (MPa) were calculated and compared between the two groups. Our results revealed that acute exposure to S. aureus, within the context of our deer tibia model, does not significantly decrease trabecular bone stiffness or yield. The results of this study may be of value clinically when assessing fracture risks for osteomyelitis or other patients whose cultures test positive for S. aureus.
Collapse
Affiliation(s)
- Emily Brooke Long
- Department of Biology, Winthrop University, Rock Hill, SC, 29733, USA.
| | - Meir Max Barak
- Department of Veterinary Biomedical Sciences, College of Veterinary Medicine, Long Island University, Brookville, NY, 11548, USA
| | | |
Collapse
|
6
|
Li S, Wang JZ, Yin B, Hu ZS, Zhang XJ, Wu W, Liu GB, Liu YK, Fu L, Zhang YZ. Atlas of Human Skeleton Hardness Obtained Using the Micro-indentation Technique. Orthop Surg 2021; 13:1417-1422. [PMID: 33973714 PMCID: PMC8274143 DOI: 10.1111/os.12841] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Revised: 09/24/2020] [Accepted: 09/28/2020] [Indexed: 11/29/2022] Open
Abstract
Objectives Measure and systematically evaluate the distribution of microhardness in the human skeleton. Methods Three fresh corpses were obtained, aged 62 (male), 45 (female), and 58 years (male). Soft tissues were removed, and all axial and unilateral appendicular bones were freshly harvested. All three skeletons were examined by X‐ray and computed tomography (CT) to exclude skeletal pathology. Only bones from donors with no known skeletal pathology were included in the study. Axial and unilateral appendicular skeleton bones from each of the three donors were obtained, except for ear ossicles, hyoid bone, tailbone, and 14 phalanges of the foot, for which samples were difficult to obtain. Precision bone specimens with a thickness of 3 mm, which were cut with a Buehler IsoMet 11‐1280‐250 low‐speed diamond saw (Buehler, USA), were obtained from all important anatomic sites in a direction perpendicular to the mechanical axis of each bone. Micro‐indentation (the Vickers hardness test) was performed on the surface of each specimen using a microhardness tester with a diamond indenter. Hardness value (HV) was computed for each indentation. Each bone specimen was divided into several regions of interest. Indentations were carefully made and computed. Then we analyzed the data to identify hardness distribution rules at different anatomic sites. Results In total, 5360 indentations were made in 1072 regions of interest in each donor. Hardness of the axial and appendicular bones were all inhomogeneous depending on the anatomic sites, but the distribution of microhardness followed certain rules. The mean hardness value ranged from 24.46 HV (HV = hardness value, kgf/mm2) for the sacrum to 53.20 HV for the shaft of the tibia. The diaphysis was harder than the metaphysis, and the proximal and distal epiphysis had lower values (8.85%– 40.39%) than the diaphysis. Among the long bone diaphyses, the tibia cortical bone (51.20 HV) was the hardest, harder than the humerus (47.25 HV), the ulna (43.26 HV), the radius (42.54 HV), and the femur (47.53 HV). However, in some anatomic sites such as the lumbar vertebra (cortical bone 32.86 HV, cancellous bone 31.25 HV), the cortical shells were sometimes not harder than the internal cancellous bones. The lumbar vertebra (32.86 HV) was harder than the cervical vertebra (28.51 HV) and the thoracic vertebra (29.01 HV). Conclusions The distribution of microhardness in the human skeleton follows certain rules. These distribution rules could be used to predict the mechanical properties of bone and progress in this field could provide data for the basis of a new three‐dimensional printing technique, which may lead to new perspectives for custom‐made implants.
Collapse
Affiliation(s)
- Sheng Li
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Jian-Zhao Wang
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Bing Yin
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Zu-Sheng Hu
- Key Biomechanics Lab of Hebei Province, Shijiazhuang, China
| | - Xiao-Juan Zhang
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Wei Wu
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Guo-Bin Liu
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Ya-Ke Liu
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Lei Fu
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| | - Ying-Ze Zhang
- The Third Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
7
|
Naihui W, Samantha B, Peter D, Sandra H, Maxim K, Sindy L, Oshan W, Stefano G, Michael C, Liora HK, Matthew S, Glenn S, Michael S, Kristine RK, Katerina D. Testing the efficacy and comparability of ZooMS protocols on archaeological bone. J Proteomics 2020; 233:104078. [PMID: 33338688 DOI: 10.1016/j.jprot.2020.104078] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Revised: 12/03/2020] [Accepted: 12/12/2020] [Indexed: 12/27/2022]
Abstract
Collagen peptide mass fingerprinting, best known as Zooarchaeology by Mass Spectrometry (or ZooMS) when applied to archaeology, has become invaluable for the taxonomic identification of archaeological collagenous materials, in particular fragmentary and modified bone remains. Prior to MALDI-based spectrometric analysis, collagen needs to be extracted from the bone's inorganic matrix, isolated and purified. Several protocols are currently employed for ZooMS analysis, however their efficacy and comparability has not been directly tested. Here, we use four different ZooMS protocols to analyze 400 bone samples from seven archaeological sites, dating to between ~500,000-2000 years ago. One of them, single-pot solid-phase-enhance sample preparation (SP3), is used for the first time as a ZooMS protocol. Our results indicate that the least-destructive ZooMS protocol which uses an ammonium bicarbonate buffer as a means of extracting collagen is most suitable for bones with good collagen preservation, whereas the acid-based methodologies can improve success rates for bones with low-to-medium collagen preservation. Since preservation of biomolecules in archaeological bones is highly variable due to age and environmental conditions, we use the percent nitrogen by weight (%N) value as an independent semi-quantitative proxy for assessing collagen content and for predicting which bones will likely result in a successful ZooMS-based identification. We find that 0.26%N as a threshold for screening material could optimize the number of spectra which produce identifications using ZooMS. SIGNIFICANCE STATEMENT: We present a direct comparison of three previously published ZooMS protocols for the analyses of archaeological bones, and the first use of an SP3-based approach to ZooMS analysis. Our results show that the acid-based ZooMS protocols increase the success rate for bones with low-medium collagen preservation. We identify 0.26%N as a threshold for optimizing the number of samples with enough collagen for successful peptide mass fingerprinting.
Collapse
Affiliation(s)
- Wang Naihui
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany.
| | - Brown Samantha
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany.
| | - Ditchfield Peter
- School of Archaeology, University of Oxford, 1 South Parks Road, Oxford, UK.
| | - Hebestreit Sandra
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany.
| | - Kozilikin Maxim
- Institute of Archaeology and Ethnography, Siberian Branch, Russian Academy of Sciences, Pr. Akademika Lavrentieva, 17, Novosibirsk 630090, Russia
| | - Luu Sindy
- Department of Anatomy, University of Otago, PO Box 56, Dunedin 9054, New Zealand.
| | - Wedage Oshan
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany; Department of History and Archaeology, University of Sri Jayewardenepura, Gangodawila, Nugegoda, Sri Lanka.
| | - Grimaldi Stefano
- LaBAAF -Laboratorio Bagolini Archeologia, Archeometria, Fotografia, CeASUm - Centro di Alti Studi Umanistici, Dipartimento di Lettere e Filosofia, Università di Trento, via T.Gar14, I-38122 Trento, Italy; IsIPU - Istituto Italiano di Paleontologia Umana, Anagni, Italy.
| | - Chazan Michael
- Department of Anthropology, Canada Institute of Evolutionary Studies, University of Toronto, 19 Russell Street, Toronto, Canada; University of the Witwatersrand, Johannesburg, South Africa.
| | - Horwitz Kolska Liora
- National Natural History Collections, The Hebrew University, Berman Building, E. Safra-Givat Ram Campus, 91904 Jerusalem, Israel
| | - Spriggs Matthew
- School of Archaeology and Anthropology, Sir Roland Wilson Bldg 120, The Australian National University, Canberra, ACT 2600, Australia.
| | | | - Shunkov Michael
- Institute of Archaeology and Ethnography, Siberian Branch, Russian Academy of Sciences, Pr. Akademika Lavrentieva, 17, Novosibirsk 630090, Russia
| | - Richter Korzow Kristine
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany.
| | - Douka Katerina
- Department of Archaeology, Max Planck Institute for the Science of Human History (MPI-SHH), Kahlaische Straße 10, 07745 Jena, Germany.
| |
Collapse
|
8
|
Nguyen JT, Barak MM. Secondary osteon structural heterogeneity between the cranial and caudal cortices of the proximal humerus in white-tailed deer. J Exp Biol 2020; 223:jeb225482. [PMID: 32366689 PMCID: PMC7295587 DOI: 10.1242/jeb.225482] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 04/27/2020] [Indexed: 01/13/2023]
Abstract
Cortical bone remodeling is an ongoing process triggered by microdamage, where osteoclasts resorb existing bone and osteoblasts deposit new bone in the form of secondary osteons (Haversian systems). Previous studies revealed regional variance in Haversian systems structure and possibly material, between opposite cortices of the same bone. As bone mechanical properties depend on tissue structure and material, it is predicted that bone mechanical properties will vary in accordance with structural and material regional heterogeneity. To test this hypothesis, we analysed the structure, mineral content and compressive stiffness of secondary bone from the cranial and caudal cortices of the white-tailed deer proximal humerus. We found significantly larger Haversian systems and canals in the cranial cortex but no significant difference in mineral content between the two cortices. Accordingly, we found no difference in compressive stiffness between the two cortices and thus our working hypothesis was rejected. As the deer humerus is curved and thus likely subjected to bending during habitual locomotion, we expect that similar to other curved long bones, the cranial cortex of the deer humerus is likely subjected primarily to tensile strains and the caudal cortex is subject primarily to compressive strains. Consequently, our results suggest that strain magnitude (larger in compression) and sign (compression versus tension) affect the osteoclasts and osteoblasts differently in the basic multicellular unit. Our results further suggest that osteoclasts are inhibited in regions of high compressive strains (creating smaller Haversian systems) while the osteoid deposition and mineralization by osteoblasts is not affected by strain magnitude and sign.
Collapse
Affiliation(s)
- Jack T Nguyen
- Department of Biology, Winthrop University, Rock Hill, SC 29733, USA
| | - Meir M Barak
- Department of Veterinary Biomedical Sciences, College of Veterinary Medicine, Long Island University, Brookville, NY 11548, USA
| |
Collapse
|
9
|
Histological, Histomorphometrical, and Biomechanical Studies of Bone-Implanted Medical Devices: Hard Resin Embedding. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1804630. [PMID: 32420323 PMCID: PMC7201441 DOI: 10.1155/2020/1804630] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 11/25/2019] [Accepted: 12/09/2019] [Indexed: 11/17/2022]
Abstract
The growing incidence of degenerative musculoskeletal disorders as well as lifestyle changes has led to an increase in the surgical procedures involving implanted medical devices in orthopedics. When studying implant/tissue interface in hard materials (i.e., metals or dense plastics) and/or in large bone segments, the hard plastic embedding of the intact undecalcified tissue envelope with the implant in situ is needed. The aim of this work is to describe the advances and the possibilities of high-temperature methyl methacrylate (MMA) embedding for the histological, histomorphometrical, and biomechanical assessment of bone-implanted medical devices. Unlike routine techniques, undecalcified bone processing histology, using high-temperature MMA, requires a complex and precise sample processing methodology and the availability of sophisticated equipment and software for both sample preparation and analyses. MMA embedding permits the evaluation of biological responses to the presence of implanted medical devices without implant removal, allowing simultaneous qualitative and quantitative histological evaluation, both static and dynamic histomorphometry, and biomechanical analyses not possible with tissue decalcification. MMA embedding, despite being a demanding procedure, is still preferred to other kinds of resin-based embedding because of its peculiar characteristics, which allow the study of samples of big dimensions also implanted with hard materials without reducing the sample or removing the material. Dynamic measurements are allowed together with biomechanical investigations at the bone-biomaterial interface, obtaining a comprehensive and precise evaluation of the safety and effectiveness of medical devices for orthopedic regenerative, reconstructive, and reparative surgery.
Collapse
|
10
|
Currey JD, Brear K, Zioupos P. Strain rate dependence of work of fracture tests on bone and similar tissues: Reflections on testing methods and mineral content effects. Bone 2019; 128:115038. [PMID: 31446116 DOI: 10.1016/j.bone.2019.115038] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 08/15/2019] [Accepted: 08/15/2019] [Indexed: 11/15/2022]
Abstract
This paper is concerned with the effect of different strain rate on the Work of Fracture (Wf) of various vertebrate mineralised tissues, controlling for the effect of mineral content and Young's modulus of elasticity. Using specimens of uniform shape and size values for the Work of Fracture of specimens tested at various deformation rates, and also the energy absorbed by notched specimens in impact, are reported. The results indicated that, of those tested, for most bone specimens the Work of Fracture measurements were constant like in the case for a 'material property'. Variations due to loading conditions (deformation rate) were small, with the exemption of antler, which is relatively poorly mineralised and in which the Work of Fracture values increased by a factor of 4 across the range from quasistatic loading to impact. The Tattersall and Tappin (1966) test has shown itself to offer some great advantages: if the quest is for a fracture toughness test for an unknown tissue it offers reliability, it is perhaps more forgiving to handling errors, it also suffers less of the influence of strain rate effects and uses relatively simple instrumentation. It is also able to demonstrate the remarkable toughness of antler bone which other more commonly used fracture toughness methods cannot do.
Collapse
Affiliation(s)
- J D Currey
- Department of Biology, University of York, York YO10 5YW, UK
| | - K Brear
- Department of Biology, University of York, York YO10 5YW, UK
| | - P Zioupos
- Musculoskeletal & Medicolegal Research group, Cranfield Forensic Institute, Cranfield University, Shrivenham SN6 8LA, UK.
| |
Collapse
|
11
|
Tang T, Wagermaier W, Schuetz R, Wang Q, Eltit F, Fratzl P, Wang R. Hypermineralization in the femoral neck of the elderly. Acta Biomater 2019; 89:330-342. [PMID: 30872111 DOI: 10.1016/j.actbio.2019.03.020] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2018] [Revised: 03/06/2019] [Accepted: 03/09/2019] [Indexed: 01/04/2023]
Abstract
Hip fragility depends on the decline in bone mass as well as changes in bone microstructure and the properties of bone mineral and organic matrix. Although it is well-established that low bone mass or osteoporosis is a key factor in hip fracture risk, it is striking to observe that 92% of 24 patients who have sustained an intracapsular hip fracture showed hypermineralization at the superior-anterior quadrant, a critical region associated with increased hip fracture risk. In-depth material studies on a total of 12 human cadaver femurs revealed increased degree of mineralization in the hypermineralized tissue: calcium weight percentage as measured by quantitative backscattered electron imaging increased by approximately 15% compared with lamellar bone; mineral-to-matrix ratio obtained by Raman microspectroscopy imaging also increased. Immunohistochemistry revealed localized type II collagen in the hypermineralized region, implying its cartilaginous nature. At the ultrastructural level, X-ray scattering revealed significantly smaller (on average 2.3 nm thick and 15.6 nm long) and less ordered bone minerals in the hypermineralized tissue. Finally, the hypermineralized tissue was more brittle than lamellar bone under hydrated state - cracks propagated easily in the hypermineralized region but stopped at the lamellar boundary. This study demonstrates that hypermineralization of femoral neck cortical bone is a source of bone fragility which is worth considering in future fracture risk assessment when the origin of hip fracture is unclear based on current evaluation standards. STATEMENT OF SIGNIFICANCE: Hypermineralization of femoral cortical bone in older adults might occur in many more hip fracture cases than presently known. Yet, this tissue remains largely unknown to the orthopedic community possibly due to coarse resolution of clinical imaging. The current study showed the hypermineralized tissue had reduced fracture resistance which could be attributed to the material changes in mineral content, organic matrix, and mineral platelets properties. It thus could be a source for fracture initiation. Consequently, we believe hypermineralization of femoral neck cortical bone should be considered in hip fragility assessment, especially when low bone mass cannot be identified as a primary contributor to hip fracture.
Collapse
Affiliation(s)
- Tengteng Tang
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam, Germany; Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Wolfgang Wagermaier
- Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam, Germany
| | - Roman Schuetz
- Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam, Germany
| | - Qiong Wang
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada; Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Felipe Eltit
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada; Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Peter Fratzl
- Department of Biomaterials, Max Planck Institute of Colloids and Interfaces, Potsdam, Germany.
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columbia, Vancouver, BC, Canada; School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada; Centre for Hip Health and Mobility, Vancouver, BC, Canada.
| |
Collapse
|
12
|
Chirchir H. Trabecular Bone Fraction Variation in Modern Humans, Fossil Hominins and Other Primates. Anat Rec (Hoboken) 2018; 302:288-305. [DOI: 10.1002/ar.23967] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2017] [Revised: 06/04/2018] [Accepted: 06/25/2018] [Indexed: 12/15/2022]
Affiliation(s)
- Habiba Chirchir
- Department of Biological SciencesMarshall University Huntington West Virginia
- Human Origins ProgramNational Museum of Natural History, Smithsonian Institution Washington, D.C
- Department of AnthropologyNew York University New York New York
| |
Collapse
|
13
|
Creecy A, Uppuganti S, Unal M, Clay Bunn R, Voziyan P, Nyman JS. Low bone toughness in the TallyHO model of juvenile type 2 diabetes does not worsen with age. Bone 2018; 110:204-214. [PMID: 29438824 PMCID: PMC5878744 DOI: 10.1016/j.bone.2018.02.005] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2017] [Revised: 02/05/2018] [Accepted: 02/08/2018] [Indexed: 01/22/2023]
Abstract
Fracture risk increases as type 2 diabetes (T2D) progresses. With the rising incidence of T2D, in particular early-onset T2D, a representative pre-clinical model is needed to study mechanisms for treating or preventing diabetic bone disease. Towards that goal, we hypothesized that fracture resistance of bone from diabetic TallyHO mice decreases as the duration of diabetes increases. Femurs and lumbar vertebrae were harvested from male, TallyHO mice and male, non-diabetic SWR/J mice at 16weeks (n≥12 per strain) and 34weeks (n≥13 per strain) of age. As is characteristic of this model of juvenile T2D, the TallyHO mice were obese and hyperglycemic at an early age (5weeks and 10weeks of age, respectively). The femur mid-shaft of TallyHO mice had higher tissue mineral density and larger cortical area, as determined by micro-computed tomography, compared to the femur mid-shaft of SWR/J mice, irrespective of age. As such, the diabetic rodent bone was structurally stronger than the non-diabetic rodent bone, but the higher peak force endured by the diaphysis during three-point (3pt) bending was not independent of the difference in body weight. Upon accounting for the structure of the femur diaphysis, the estimated toughness at 16weeks and 34weeks was lower for the diabetic mice than for non-diabetic controls, but neither toughness nor estimated material strength and resistance to crack growth (3pt bending of contralateral notched femur) decreased as the duration of hyperglycemia increased. With respect to trabecular bone, there were no differences in the compressive strength of the L6 vertebral strength between diabetic and non-diabetic mice at both ages despite a lower trabecular bone volume for the TallyHO than for the SWR/J mice at 34weeks. Amide I sub-peak ratios as determined by Raman Spectroscopy analysis of the femur diaphysis suggested a difference in collagen structure between diabetic and non-diabetic mice, although there was not a significant difference in matrix pentosidine between the groups. Overall, the fracture resistance of bone in the TallyHO model of T2D did not progressively decrease with increasing duration of hyperglycemia. However, given the variability in hyperglycemia in this model, there were correlations between blood glucose levels and certain structural properties including peak force.
Collapse
Affiliation(s)
- Amy Creecy
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, United States; Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232, United States
| | - Sasidhar Uppuganti
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232, United States
| | - Mustafa Unal
- Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232, United States
| | - R Clay Bunn
- University of Kentucky Barnstable Brown Diabetes Center, Lexington, KY 40536, United States; Department of Pediatrics, University of Kentucky College of Medicine, Lexington, KY 40536, United States
| | - Paul Voziyan
- Department of Medicine, Division of Nephrology, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Center for Matrix Biology, Vanderbilt University Medical Center, Nashville, TN 37232, United States
| | - Jeffry S Nyman
- Department of Biomedical Engineering, Vanderbilt University, Nashville, TN 37232, United States; Department of Orthopaedic Surgery & Rehabilitation, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Center for Bone Biology, Vanderbilt University Medical Center, Nashville, TN 37232, United States; Department of Veterans Affairs, Tennessee Valley Healthcare System, Nashville, TN 37212, United States.
| |
Collapse
|
14
|
Reinforcements in avian wing bones: Experiments, analysis, and modeling. J Mech Behav Biomed Mater 2017; 76:85-96. [DOI: 10.1016/j.jmbbm.2017.07.020] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Revised: 07/10/2017] [Accepted: 07/13/2017] [Indexed: 11/30/2022]
|
15
|
Chirchir H, Ruff CB, Junno JA, Potts R. Low trabecular bone density in recent sedentary modern humans. AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY 2017; 162:550-560. [PMID: 28101969 DOI: 10.1002/ajpa.23138] [Citation(s) in RCA: 42] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Revised: 11/08/2016] [Accepted: 11/15/2016] [Indexed: 01/18/2023]
Abstract
OBJECTIVES Research on a limited number of samples suggests that trabecular bone density (i.e., bone volume fraction, BVF) within specific articulations is lower among more sedentary Holocene agricultural populations compared with Holocene foragers, implying that activity levels have a significant effect on trabecular BVF. However, it is unclear to what extent BVF differs among groups with varying activity levels and how general this phenomenon is across multiple limb articulations. Here, we test two hypotheses that: (i) sedentary populations have lower BVF compared with active populations across limb articulations; and (ii) these declines are more uniform in the lower limb (because of its more direct relationship to mobility), and more variable in the upper limb. MATERIALS AND METHODS We estimated BVF in seven lower and upper limb articulations of five Holocene population samples with subsistence strategies spanning from foraging through horticultural to industrial using pQCT (peripheral Quantitative Computed Tomography). RESULTS Both hypotheses are largely supported. First, the most active groups have significantly greater BVF in most limb elements compared with more sedentary groups. Second, all sedentary groups have relatively similar (and lower) BVF in the lower limb but show more variation in upper limb articulations. CONCLUSIONS These results suggest that a decline in activity levels associated with the adoption of agriculture and industrialization significantly contributed to the reduction in BVF in recent modern humans, but specific behavioral changes, particularly in the upper limb, also affected these patterns.
Collapse
Affiliation(s)
- Habiba Chirchir
- Department of Biological Sciences, Marshall University, Huntington, West Virginia, 25755.,Department of Anthropology, Human Origins Program, National Museum of Natural History, Smithsonian Institution, Washington, 20013
| | - Christopher B Ruff
- Center for Functional Anatomy and Evolution, Johns Hopkins University School of Medicine, Baltimore, Maryland, 21205
| | | | - Richard Potts
- Department of Anthropology, Human Origins Program, National Museum of Natural History, Smithsonian Institution, Washington, 20013.,Department of Earth Sciences, National Museums of Kenya, Nairobi, Kenya
| |
Collapse
|
16
|
Sowoidnich K, Churchwell JH, Buckley K, Goodship AE, Parker AW, Matousek P. Spatially offset Raman spectroscopy for photon migration studies in bones with different mineralization levels. Analyst 2017; 142:3219-3226. [DOI: 10.1039/c7an00408g] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
This study provides a deeper understanding of bone's optical properties which is essential to the development of SORS-based diagnostic tools.
Collapse
Affiliation(s)
- Kay Sowoidnich
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - John H. Churchwell
- UCL Institute of Orthopaedics and Musculoskeletal Science
- Royal National Orthopaedic Hospital
- London HA7 4LP
- UK
| | - Kevin Buckley
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - Allen E. Goodship
- UCL Institute of Orthopaedics and Musculoskeletal Science
- Royal National Orthopaedic Hospital
- London HA7 4LP
- UK
| | - Anthony W. Parker
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| | - Pavel Matousek
- Central Laser Facility
- Research Complex at Harwell
- STFC Rutherford Appleton Laboratory
- Didcot OX11 0QX
- UK
| |
Collapse
|
17
|
Dumont M, de Buffrénil V, Miján I, Lambert O. Structure and growth pattern of the bizarre hemispheric prominence on the rostrum of the fossil beaked whaleGlobicetus hiberus(Mammalia, Cetacea, Ziphiidae). J Morphol 2016; 277:1292-308. [DOI: 10.1002/jmor.20575] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2016] [Revised: 06/01/2016] [Accepted: 06/18/2016] [Indexed: 11/09/2022]
Affiliation(s)
- Maïtena Dumont
- Departement Ecologie et Gestion de la Biodiversite; UMR CNRS/MNHN 7179, ‘Mécanismes Adaptatifs: des Organismes aux Communautés’; 55 rue Buffon Paris 75005 France
| | - Vivian de Buffrénil
- Département Histoire de la Terre; Muséum National d'Histoire Naturelle, CNRS-UMR 7207 (CR2P), Bâtiment de Géologie CC 48; 57 rue Cuvier F-75231 Paris Cedex 05 France
| | - Ismael Miján
- Departement Marine Mammal; Sociedade Galega de Historia Natural; Praza De Canido S/N E-15401 Ferrol España
| | - Olivier Lambert
- Institut Royal des Sciences Naturelles de Belgique; D.O. Terre et Histoire de la Vie; 29 rue Vautier B-1000 Bruxelles Belgique
| |
Collapse
|
18
|
Limited Trabecular Bone Density Heterogeneity in the Human Skeleton. ANATOMY RESEARCH INTERNATIONAL 2016; 2016:9295383. [PMID: 27148458 PMCID: PMC4842361 DOI: 10.1155/2016/9295383] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Revised: 03/03/2016] [Accepted: 03/10/2016] [Indexed: 01/05/2023]
Abstract
There is evidence for variation in trabecular bone density and volume within an individual skeleton, albeit in a few anatomical sites, which is partly dependent on mechanical loading. However, little is known regarding the basic variation in trabecular bone density throughout the skeleton in healthy human adults. This is because research on bone density has been confined to a few skeletal elements, which can be readily measured using available imaging technology particularly in clinical settings. This study comprehensively investigates the distribution of trabecular bone density within the human skeleton in nine skeletal sites (femur, proximal and distal tibia, third metatarsal, humerus, ulna, radius, third metacarpal, and axis) in a sample of N = 20 individuals (11 males and 9 females). pQCT results showed that the proximal ulna (mean = 231.3 mg/cm3) and axis vertebra (mean = 234.3 mg/cm3) displayed significantly greater (p < 0.01) trabecular bone density than other elements, whereas there was no significant variation among the rest of the elements (p > 0.01). The homogeneity of the majority of elements suggests that these sites are potentially responsive to site-specific genetic factors. Secondly, the lack of correlation between elements (p > 0.05) suggests that density measurements of one anatomical region are not necessarily accurate measures of other anatomical regions.
Collapse
|
19
|
A mineralogical study in contrasts: highly mineralized whale rostrum and human enamel. Sci Rep 2015; 5:16511. [PMID: 26552356 PMCID: PMC4639718 DOI: 10.1038/srep16511] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Accepted: 10/14/2015] [Indexed: 11/08/2022] Open
Abstract
The outermost enamel of the human tooth and the rostrum of the whale Mesoplodon densirostris are two highly mineralized tissues that contain over 95 wt.% mineral, i.e., bioapatite. However, the same mineral type (carbonated hydroxylapatite) does not yield the same material properties, as revealed by Raman spectroscopy, scanning electron microscopy, electron microprobe analysis, and synchrotron X-ray diffraction analysis. Overall, the outermost enamel of a tooth has more homogeneous physical and chemical features than the rostrum. Chemical comparison of rostrum and enamel shows bioapatite in the rostrum to be enriched in Na, Mg, CO3, and S, whereas the outermost enamel shows only a slightly enriched Cl concentration. Morphologically, mineral rods (at tens of μm scale), crystallites and prisms (at μm and sub-μm scale), and platelets (at tens of nm scale) all demonstrate less organized texture in the rostrum than in enamel. Such contrasts between two mineralized tissues suggest distinct pathways of biomineralization, e.g., the nature of the equilibrium between mineral and body fluid. This study illustrates the remarkable flexibility of the apatite mineral structure to match its chemical and physical properties to specific biological needs within the same animal or between species.
Collapse
|
20
|
Experimentally-based multiscale model of the elastic moduli of bovine trabecular bone and its constituents. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 54:207-16. [PMID: 26046284 DOI: 10.1016/j.msec.2015.02.044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2014] [Revised: 01/14/2015] [Accepted: 02/24/2015] [Indexed: 11/23/2022]
Abstract
The elastic moduli of trabecular bone were modeled using an analytical multiscale approach. Trabecular bone was represented as a porous nanocomposite material with a hierarchical structure spanning from the collagen-mineral level to the trabecular architecture level. In parallel, compression testing was done on bovine femoral trabecular bone samples in two anatomical directions, parallel to the femoral neck axis and perpendicular to it, and the measured elastic moduli were compared with the corresponding theoretical results. To gain insights on the interaction of collagen and minerals at the nanoscale, bone samples were deproteinized or demineralized. After such processing, the treated samples remained as self-standing structures and were tested in compression. Micro-computed tomography was used to characterize the hierarchical structure of these three bone types and to quantify the amount of bone porosity. The obtained experimental data served as inputs to the multiscale model and guided us to represent bone as an interpenetrating composite material. Good agreement was found between the theory and experiments for the elastic moduli of the untreated, deproteinized, and demineralized trabecular bone.
Collapse
|
21
|
Wornham DP, Hajjawi MO, Orriss IR, Arnett TR. Strontium potently inhibits mineralisation in bone-forming primary rat osteoblast cultures and reduces numbers of osteoclasts in mouse marrow cultures. Osteoporos Int 2014; 25:2477-84. [PMID: 25048011 PMCID: PMC4176572 DOI: 10.1007/s00198-014-2791-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 06/20/2014] [Indexed: 11/30/2022]
Abstract
SUMMARY The basic mechanisms by which strontium ranelate acts on bone are still unclear. We show that an important action of strontium salts is to block calcification in cultures of osteoblasts, the bone-forming cells. These results suggest that strontium treatment could have previously overlooked effects on bone. INTRODUCTION The basic mechanisms of action of strontium ranelate (SrR) on bone have remained unclear. We studied the direct actions of Sr(2+) salts in functional cultures of osteoblasts and osteoclasts. METHODS Cultures of primary osteoblasts from rat calvariae and osteoclast-forming mouse marrow cells were treated continuously with either SrR or strontium chloride (SrCl2). RESULTS Abundant, discretely mineralised 'trabecular' bone structures formed in control osteoblast cultures after 14 days. SrR at 0.01, 0.1 and 1 mM inhibited mineralisation to 59, 98 and 100 % (all p < 0.001) of control values, respectively. SrCl2 at the same concentrations caused similar inhibitions. Osteoblast cell numbers and alkaline phosphatase activity were unaltered. SrR dose-dependently reduced the formation of multinucleated osteoclasts from marrow mononuclear cells cultured on dentine for 8 days in the presence of macrophage colony-stimulating factor (M-CSF) and receptor activator of nuclear factor kappa B ligand (RANKL), with a 50 % inhibition occurring at 1 mM; SrCl2 was slightly less effective, eliciting a maximal 30 % inhibition. Corresponding decreases in total resorption pit formation were observed, suggesting Sr(2+) salts affect osteoclast formation rather than resorptive activity. CONCLUSION Our findings are consistent with the documented physicochemical inhibitory action of Sr(2+) on mineralisation but contrast with reports that Sr(2+) increases osteoblast activity and number in vitro. Our results suggest that rather than acting as an agent that 'uncouples' bone formation and resorption, Sr(2+) acts as a global inhibitor of bone cell function, with particularly marked effects on mineralisation. The potential effects of long-term Sr(2+) on secondary mineralisation in bone deserve investigation.
Collapse
Affiliation(s)
- D. P. Wornham
- Department of Cell and Developmental Biology, University College London, Gower Street, London, WC1E 6BT UK
| | - M. O. Hajjawi
- Department of Cell and Developmental Biology, University College London, Gower Street, London, WC1E 6BT UK
| | - I. R. Orriss
- Department of Cell and Developmental Biology, University College London, Gower Street, London, WC1E 6BT UK
- Royal Veterinary College, Royal College Street, London, NW1 0TU UK
| | - T. R. Arnett
- Department of Cell and Developmental Biology, University College London, Gower Street, London, WC1E 6BT UK
| |
Collapse
|
22
|
Tubelli AA, Zosuls A, Ketten DR, Mountain DC. Elastic Modulus of Cetacean Auditory Ossicles. Anat Rec (Hoboken) 2014; 297:892-900. [DOI: 10.1002/ar.22896] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2013] [Revised: 09/09/2013] [Accepted: 01/15/2014] [Indexed: 11/12/2022]
Affiliation(s)
- Andrew A. Tubelli
- Department of Biomedical Engineering; Hearing Research Center, Boston University; Boston Massachusetts
| | - Aleks Zosuls
- Department of Biomedical Engineering; Hearing Research Center, Boston University; Boston Massachusetts
| | - Darlene R. Ketten
- Department of Biology; Woods Hole Oceanographic Institution, Marine Research Facility; Woods Hole Massachusetts
- Department of Otology and Laryngology; Harvard Medical School, Massachusetts Eye and Ear Infirmary; Boston Massachusetts
| | - David C. Mountain
- Department of Biomedical Engineering; Hearing Research Center, Boston University; Boston Massachusetts
| |
Collapse
|
23
|
Louchart A, Sire JY, Mourer-Chauviré C, Geraads D, Viriot L, de Buffrénil V. Structure and growth pattern of pseudoteeth in Pelagornis mauretanicus (Aves, Odontopterygiformes, Pelagornithidae). PLoS One 2013; 8:e80372. [PMID: 24244680 PMCID: PMC3828250 DOI: 10.1371/journal.pone.0080372] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2013] [Accepted: 10/02/2013] [Indexed: 11/25/2022] Open
Abstract
The extinct Odontopterygiformes are the sole birds known to possess strong and sharp bony pseudoteeth, the shape and location of which are closely mimetic of real teeth. The structure of the pseudoteeth is investigated here in a late Pliocene/early Pleistocene species, Pelagornis mauretanicus, using X-ray microtomography and thin sections. The results are interpreted with regard to the pseudotooth mode of growth, and have implications concerning aspects of Pelagornis ecology. The larger pseudoteeth are hollow and approximately cone-shaped, and the smaller ones are rostro-caudally constricted. The walls of pseudoteeth are composed of bone tissue of the fibro-lamellar type, which is intensively remodeled by Haversian substitution. The jaw bones display the same structure as the pseudoteeth, but their vascular canals are oriented parallel to the long axis of the bones, whereas they are perpendicular to this direction in the pseudoteeth. There is no hiatus or evidence of a fusion between the pseudoteeth and the jaw bones. Two possible models for pseudotooth growth are derived from the histological data. The most plausible model is that pseudotooth growth began after the completion of jaw bone growth, as a simple local protraction of periosteal osteogenic activity. Pseudotooth development thus occurred relatively late during ontogeny. The highly vascularized structure and the relative abundance of parallel-fibered bone tissue in the pseudoteeth suggest poor mechanical capabilities. The pseudoteeth were most likely covered and protected by the hardened, keratinized rhamphotheca in the adult during life. The late development of the pseudoteeth would involve a similarly late and/or partial hardening of the rhamphotheca, as displayed by extant Anseriformes, Apterygiformes and some Charadriiformes. This would add support to the hypothesis of a close phylogenetic relationship between Odontopterygiformes and Anseriformes. The late maturation of the Pelagornis feeding apparatus, and hence the delayed capability for efficient prey catching, suggests that Pelagornis was altricial.
Collapse
Affiliation(s)
- Antoine Louchart
- Centre National de la Recherche Scientifique, Unité Mixte de Recherche 5242, Institut de Génomique Fonctionnelle de Lyon, Equipe évo-dévo de la denture chez les vertébrés, Ecole Normale Supérieure de Lyon, Université Lyon 1, Lyon, France
- * E-mail:
| | - Jean-Yves Sire
- Université Pierre et Marie Curie, Unité Mixte de Recherche 7138 - Systématique, Adaptation, Evolution, Equipe évolution et développement du squelette, Paris, France
| | - Cécile Mourer-Chauviré
- Laboratoire de Géologie de Lyon, Terre, Planètes, Environnement, Unité Mixte de Recherche 5276, Centre National de la Recherche Scientifique, Ecole Normale Supérieure de Lyon, Université Lyon 1, Villeurbanne, France
| | - Denis Geraads
- Centre National de la Recherche Scientifique, Unité Mixte de Recherche 7207 – Centre de Recherches sur la Paléobiodiversité et les Paléoenvironnements, Département Histoire de la Terre, Muséum National d'Histoire Naturelle, Paris, France
| | - Laurent Viriot
- Centre National de la Recherche Scientifique, Unité Mixte de Recherche 5242, Institut de Génomique Fonctionnelle de Lyon, Equipe évo-dévo de la denture chez les vertébrés, Ecole Normale Supérieure de Lyon, Université Lyon 1, Lyon, France
| | - Vivian de Buffrénil
- Centre National de la Recherche Scientifique, Unité Mixte de Recherche 7207 – Centre de Recherches sur la Paléobiodiversité et les Paléoenvironnements, Département Histoire de la Terre, Muséum National d'Histoire Naturelle, Paris, France
| |
Collapse
|
24
|
Porter MM, Novitskaya E, Castro-Ceseña AB, Meyers MA, McKittrick J. Highly deformable bones: unusual deformation mechanisms of seahorse armor. Acta Biomater 2013; 9:6763-70. [PMID: 23470547 DOI: 10.1016/j.actbio.2013.02.045] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Revised: 02/26/2013] [Accepted: 02/26/2013] [Indexed: 01/10/2023]
Abstract
Multifunctional materials and devices found in nature serve as inspiration for advanced synthetic materials, structures and robotics. Here, we elucidate the architecture and unusual deformation mechanisms of seahorse tails that provide prehension as well as protection against predators. The seahorse tail is composed of subdermal bony plates arranged in articulating ring-like segments that overlap for controlled ventral bending and twisting. The bony plates are highly deformable materials designed to slide past one another and buckle when compressed. This complex plate and segment motion, along with the unique hardness distribution and structural hierarchy of each plate, provide seahorses with joint flexibility while shielding them against impact and crushing. Mimicking seahorse armor may lead to novel bio-inspired technologies, such as flexible armor, fracture-resistant structures or prehensile robotics.
Collapse
|
25
|
Brassey CA, Kitchener AC, Withers PJ, Manning PL, Sellers WI. The Role of Cross-Sectional Geometry, Curvature, and Limb Posture in Maintaining Equal Safety Factors: A Computed Tomography Study. Anat Rec (Hoboken) 2013; 296:395-413. [DOI: 10.1002/ar.22658] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Accepted: 12/16/2012] [Indexed: 11/09/2022]
Affiliation(s)
| | - Andrew C. Kitchener
- Department of Natural Sciences; National Museum of Scotland; Edinburgh United Kingdom
- Institute of Geography; School of Geosciences; University of Edinburgh; Drummond Street Edinburgh United Kingdom
| | - Philip J. Withers
- Henry Moseley X-Ray Imaging Facility; School of Materials; University of Manchester; Manchester United Kingdom
| | - Phillip L. Manning
- School of Earth; Atmospheric and Environmental Sciences; University of Manchester; Manchester United Kingdom
| | - William I. Sellers
- Faculty of Life Sciences; University of Manchester; Manchester United Kingdom
| |
Collapse
|
26
|
Li Z, Pasteris JD, Novack D. Hypermineralized whale rostrum as the exemplar for bone mineral. Connect Tissue Res 2013:130125073616004. [PMID: 23350666 DOI: 10.3109/02770903.2013.769973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Although bone is a nanocomposite of mineral and collagen, mineral has been the more elusive component to study. A standard for bone mineral clearly is needed. We hypothesized that the most natural, least-processed bone mineral could be retrieved from the most highly mineralized bone. We therefore studied the rostrum of the toothed whale Mesoplodon densirostris, which has the densest recognized bone. Essential to establishment of a standard for bone mineral is documentation that the proposed tissue is bone-like in all properties except for its remarkably high concentration of mineral. Transmitted-light microscopy of unstained sections of rostral material shows normal bone morphology in osteon geometry, lacunae concentration, and vasculature development. Stained sections reveal extremely low density of thin collagen fibers throughout most of the bone, but enrichment in and thicker collagen fibers around vascular holes and in a minority of osteons. FE-SEM shows the rostrum to consist mostly of dense mineral prisms. Most rostral areas have the same chemical-structural features, Raman spectroscopically dominated by strong bands at ∼962 Δcm(-1) and weak bands at ∼2940 Δcm(-1). Spectral features indicate that the rostrum is composed mainly of the calcium phosphate mineral apatite and has only about 4 wt.% organic content. The degree of carbonate substitution (∼8.5 wt.% carbonate) in the apatite is in the upper range found in most types of bone. We conclude that, despite its enamel-like extraordinarily high degree of mineralization, the rostrum is in all other features bone-like. Its mineral component is the long-sought uncontaminated, unaltered exemplar of bone mineral.
Collapse
Affiliation(s)
- Zhen Li
- Department of Earth and Planetary Sciences and Center for Materials Innovation, Washington University in St. Louis , St. Louis, MO , USA
| | | | | |
Collapse
|
27
|
Abstract
Although bone is a nanocomposite of mineral and collagen, mineral has been the more elusive component of study. A standard for bone mineral is clearly needed. We hypothesized that the most natural, least-processed bone mineral could be retrieved from the most highly mineralized bone. We therefore studied the rostrum of the toothed whale Mesoplodon densirostris, which has the densest recognized bone. Essential to establishment of a standard for bone mineral is the documentation that the proposed tissue is bone-like in all properties except for its remarkably high concentration of mineral. Transmitted-light microscopy of unstained sections of rostral material shows normal bone morphology in osteon geometry, lacunae concentration, and vasculature development. Stained sections reveal extremely low density of thin collagen fibers in most of the bone, but enrichment of thicker collagen fibers around vascular holes and in a minority of osteons. Field-emission scanning electron microscopy shows the rostrum mostly consists of dense mineral prisms. Most rostral areas have the same chemical-structural features, i.e., Raman spectroscopically dominated by strong bands at ∼962 Δcm(-1) and weak bands at ∼2940 Δcm(-1). Spectral features indicate that the rostrum is composed mainly of the calcium phosphate mineral apatite and has only about 4 wt.% organic content. The degree of carbonate substitution (∼8.5 wt.% carbonate) in the apatite is in the upper range found in most types of bone. We conclude that, despite its enamel-like extraordinarily high degree of mineralization, the rostrum is in all other features bone-like. Its mineral component is the long-sought uncontaminated, unaltered exemplar of bone mineral.
Collapse
Affiliation(s)
- Zhen Li
- Department of Earth and Planetary Sciences and Center for Materials Innovation, Washington University in St. Louis, St. Louis, MO, USA
| | - Jill D. Pasteris
- Department of Earth and Planetary Sciences and Center for Materials Innovation, Washington University in St. Louis, St. Louis, MO, USA,Corresponding author: Jill D. Pasteris, Ph.D. Washington University in St. Louis, C.B. 1169, One Brookings Dr. Dept. of Earth and Planetary Sciences, St. Louis, MO 63130-4899 USA, , tel. 001-314-935-5434; FAX 001-314-935-7361
| | - Deborah Novack
- Division of Bone and Mineral Diseases, Department of Medicine, Washington University School of Medicine, St Louis, MO, USA
| |
Collapse
|
28
|
Öhman C, Zwierzak I, Baleani M, Viceconti M. Human bone hardness seems to depend on tissue type but not on anatomical site in the long bones of an old subject. Proc Inst Mech Eng H 2012; 227:200-6. [DOI: 10.1177/0954411912459424] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
It has been hypothesised that among different human subjects, the bone tissue quality varies as a function of the bone segment morphology. The aim of this study was to assess and compare the quality, evaluated in terms of hardness of packages of lamellae, of cortical and trabecular bones, at different anatomical sites within the human skeleton. The contralateral six long bones of an old human subject were indented at different levels along the diaphysis and at both epiphyses of each bone. Hardness value, which is correlated to the degree of mineralisation, of both cortical and trabecular bone tissues was calculated for each indentation location. It was found that the cortical bone tissue was harder (+18%) than the trabecular one. In general, the bone hardness was found to be locally highly heterogeneous. In fact, considering one single slice obtained for a bone segment, the coefficient of variation of the hardness values was up to 12% for cortical bone and up to 17% for trabecular bone. However, the tissue hardness was on average quite homogeneous within and among the long bones of the studied donor, although differences up to 9% among levels and up to 7% among bone segments were found. These findings seem not to support the mentioned hypothesis, at least not for the long bones of an old subject.
Collapse
Affiliation(s)
- Caroline Öhman
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Iwona Zwierzak
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | | | - Marco Viceconti
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
29
|
Macesic LJ, Summers AP. Flexural stiffness and composition of the batoid propterygium as predictors of punting ability. J Exp Biol 2012; 215:2003-12. [DOI: 10.1242/jeb.061598] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARY
Elasmobranchs (sharks, skates and rays) perform at the extremes of locomotion and feeding (i.e. long migrations, high-speed swimming and durophagy). However, very little is known about their cartilaginous skeletal structure and composition in response to loading regimes. In this study, we investigated a batoid (skate and ray) appendicular skeletal element, the propterygium, and its response to forces experienced during punting (benthic pelvic fin locomotion). Punting places a flexural load on this thin, rod-like element. The goals for our study were to determine: (1) the mechanical and compositional properties of the propterygium and (2) whether these properties correlate with punting ability. Using five batoid species of varying punting ability, we employed a three-point bending test and found that propterygium flexural stiffness (33.74–180.16 Nm2) was similar to values found in bone and could predict punting ability. Variation in flexural stiffness resulted from differences in mineral content (24.4–48.9% dry mass) and the second moment of area. Propterygia material stiffness (140–2533 MPa) approached the lower limit of bone despite having less than one-third of its mineral content. This drastically lower mineral content is reflected in the radius-to-thickness ratio of the cross-section (mean ± s.e.m.=5.5±0.44), which is comparatively much higher than bony vertebrates. This indicates that elasmobranchs may have evolved skeletal elements that increase buoyancy without sacrificing mechanical properties. Our results highlight the functional parallels between a cartilaginous and bony skeleton despite dramatic compositional differences, and provide insight into how environmental factors may affect cartilaginous skeletal development.
Collapse
Affiliation(s)
| | - Adam P. Summers
- Friday Harbor Laboratories, University of Washington, Friday Harbor, WA 98250, USA
| |
Collapse
|
30
|
Cohen L, Dean M, Shipov A, Atkins A, Monsonego-Ornan E, Shahar R. Comparison of structural, architectural and mechanical aspects of cellular and acellular bone in two teleost fish. J Exp Biol 2012; 215:1983-93. [DOI: 10.1242/jeb.064790] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARY
The histological diversity of the skeletal tissues of fishes is impressive compared with that of other vertebrate groups, yet our understanding of the functional consequences of this diversity is limited. In particular, although it has been known since the mid-1800s that a large number of fish species possess acellular bones, the mechanical advantages and consequences of this structural characteristic – and therefore the nature of the evolution of this feature – remain unclear. Although several studies have examined the material properties of fish bone, these have used a variety of techniques and there have been no direct contrasts of acellular and cellular bone. We report on a comparison of the structural and mechanical properties of the ribs and opercula between two freshwater fish – the common carp Cyprinus carpio (a fish with cellular bone) and the tilapia Oreochromis aureus (a fish with acellular bone). We used light microscopy to show that the bones in both fish species exhibit poor blood supply and possess discrete tissue zones, with visible layering suggesting differences in the underlying collagen architecture. We performed identical micromechanical testing protocols on samples of the two bone types to determine the mechanical properties of the bone material of opercula and ribs. Our data support the consensus of literature values, indicating that Young’s moduli of cellular and acellular bones are in the same range, and lower than Young’s moduli of the bones of mammals and birds. Despite these similarities in mechanical properties between the bone tissues of the fish species tested here, cellular bone had significantly lower mineral content than acellular bone; furthermore, the percentage ash content and bone mineral density values (derived from micro-CT scans) show that the bone of these fishes is less mineralized than amniote bone. Although we cannot generalize from our data to the numerous remaining teleost species, the results presented here suggest that while cellular and acellular fish bone may perform similarly from a mechanical standpoint, there are previously unappreciated differences in the structure and composition of these bone types.
Collapse
Affiliation(s)
- Liat Cohen
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| | - Mason Dean
- Max Planck Institute of Colloids and Interfaces, Department of Biomaterials, Am Mühlenberg 1, 14424 Potsdam, Germany
| | - Anna Shipov
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| | - Ayelet Atkins
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| | - Efrat Monsonego-Ornan
- School of Biochemistry and Nutrition, The Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| | - Ron Shahar
- Koret School of Veterinary Medicine, The Robert H. Smith Faculty of Agriculture, Food and Environment, The Hebrew University of Jerusalem, Israel
| |
Collapse
|
31
|
Reduced tissue hardness of trabecular bone is associated with severe osteoarthritis. J Biomech 2011; 44:1593-8. [PMID: 21496822 DOI: 10.1016/j.jbiomech.2010.12.022] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Revised: 11/18/2010] [Accepted: 12/21/2010] [Indexed: 11/23/2022]
Abstract
This study investigated whether changes in hardness of human trabecular bone are associated with osteoarthritis. Twenty femoral heads extracted from subjects without musculoskeletal diseases (subject age: 49-83 years) and twenty femoral heads extracted from osteoarthritic subjects (subject age: 42-85 years) were tested. Sixty indentations were performed along the main trabecular direction of each sample at a fixed relative distance. Two microstructures were found on the indenting locations: packs of parallel-lamellae (PL) and secondary osteons (SO). A 25gf load was applied for 15s and the Vickers Hardness (HV) was assessed. Trabecular tissue extracted from osteoarthritic subjects was found to be about 13% less hard compared to tissue extracted from non-pathologic subjects. However, tissue hardness was not significantly affected by gender or age. The SO was 10% less hard than the PL for both pathologic and non-pathologic tissues. A hardness of 34.1HV for PL and 30.8HV for SO was found for the non-pathologic tissue. For osteoarthritic tissue, the hardness was 30.2HV for PL and 27.1HV for SO. In the bone tissue extracted from osteoarthritic subjects the occurrence of indenting a SO (28%) was higher than that observed in the non-pathological tissue (15%). Osteoarthritis is associated with reduced tissue hardness and alterations in microstructure of the trabecular bone tissue. Gender does not significantly affect trabecular bone hardness either in non-pathological or osteoarthritic subjects. A similar conclusion can be drawn for age, although a larger donor sample size would be necessary to definitively exclude the existence of a slight effect.
Collapse
|
32
|
Local irradiation alters bone morphology and increases bone fragility in a mouse model. J Biomech 2010; 43:2738-46. [PMID: 20655052 DOI: 10.1016/j.jbiomech.2010.06.017] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2010] [Revised: 06/07/2010] [Accepted: 06/08/2010] [Indexed: 11/24/2022]
Abstract
Insufficiency fracture following radiation therapy (RTx) is a challenging clinical problem and typical bone mass measures fail to predict these fractures. The goals of this research were to develop a mouse model that results in reduced bone strength following focal irradiation, quantify morphological and strength changes occurring over time, and determine if a positive correlation between bone morphology and strength is retained after irradiation. Right hind limbs of 13 week-old female Balb/c mice were irradiated (5 or 20 Gy) using a therapeutic X-ray unit. Left limbs served as control. Animals were euthanized at 2, 6, 12, or 26 weeks. Axial compression tests of the distal femur were used to quantify whole bone strength. Specimen-specific, non-linear finite element (FE) analyses of the mechanical tests were performed using voxel-based meshes with two different material failure models: a linear bone density-strength relationship and a non-linear 'embrittled' relationship. Radiation resulted in a dose dependent increase in cortical bone density and marked loss of trabecular bone, measured using micro-CT. An early (2 week) increase in bone volume was associated with an increase in bone strength following irradiation; at 12 weeks there was a loss of bone strength despite higher bone volume for irradiated limbs. There was a positive correlation between bone volume bone and strength in control (r²=0.63) but not irradiated femora (r²=0.08). FE analysis with a constant strain failure model resulted in improved prediction of bone strength for irradiated limbs (r²=0.34) and this was improved further with the embrittled material model (r²=0.46). In summary, focal irradiation leads to substantial changes in bone morphology and strength with time, where there is a decreased bone strength following irradiation in the face of increasing bone mass; FE models with a non-linear embrittled material model were most successful in simulating these experimental findings.
Collapse
|
33
|
Karjalainen JP, Töyräs J, Riekkinen O, Hakulinen M, Jurvelin JS. Ultrasound backscatter imaging provides frequency-dependent information on structure, composition and mechanical properties of human trabecular bone. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:1376-84. [PMID: 19525060 DOI: 10.1016/j.ultrasmedbio.2009.03.011] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2009] [Revised: 02/26/2009] [Accepted: 03/08/2009] [Indexed: 05/10/2023]
Abstract
The strength as well as the acoustic properties of trabecular bone are determined by its structure and composition. Consequently, tissue structure and compositional properties also affect the ultrasound propagation in bone. The diagnostic potential of ultrasound has not been fully exploited in clinical quantitative ultrasound devices. The aim of this study was to investigate the ability of quantitative ultrasound pulse-echo imaging, conducted over a broad range of frequencies (1 to 5 MHz), to predict the mechanics, composition and microstructure of trabecular bone. Ultrasound reflection and backscatter parameters correlated significantly with the ultimate strength of the trabecular bone and the bone volume fraction (r=0.76-0.90, n=20, p<0.01). Ultrasound backscatter associated significantly (independently of bone structure or mineral content) with the collagen content of the bone matrix (r=0.75, r(adjusted)=0.66, p<0.01). Interestingly, the applied ultrasound frequency seemed to relate the sensitivity of ultrasound backscatter to different properties of trabecular bone. At frequencies ranging from 1 to 3.5 MHz, the ultrasound backscatter associated significantly with the tissue mechanical and structural parameters. At 5MHz, the composition of the bone matrix was a more significant determinant of the measured backscatter. This study provides useful information for optimizing the use of pulse-echo measurements, and thereby further emphasizes the diagnostic potential of the ultrasound backscatter measurements of trabecular bone.
Collapse
|
34
|
Zwierzak I, Baleani M, Viceconti M. Microindentation on cortical human bone: Effects of tissue condition and indentation location on hardness values. Proc Inst Mech Eng H 2009; 223:913-8. [DOI: 10.1243/09544119jeim634] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The hardness of cortical human bone has been measured on osteons in different conditions. However, no data are reported in the literature regarding the effect of cortical tissue condition and indentation location on the measured hardness values. This study aimed to investigate whether the hardness of the human cortical bone evaluated by micro-indentation is influenced, first, by the tissue condition and, second, by the distance of the indentation from the edge of the Haversian canal. Two femura were collected from a subject without musculoskeletal disease. The Vickers hardness was measured by means of microindentation (applied load, 100 gf) on osteons with a cross-section greater than 200 μm. The tests were performed on wet and embedded tissue at different distances from the Haversian canal edge (30—150 μm). No significant differences were found in hardness values between the two contralateral femura. Embedded tissue was significantly harder (12 per cent) than wet tissue. No significant differences were found in hardness values measured at different distances from the Haversian canal edge except for those closer than 60 μm. Therefore, indentations cannot be performed on osteons small in cross-section, since the distance from the closer pore has to be controlled. They should be performed on wet tissue, to avoid an offset in the measured hardness.
Collapse
Affiliation(s)
- I Zwierzak
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - M Baleani
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| | - M Viceconti
- Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
35
|
Courtland HW, Nasser P, Goldstone AB, Spevak L, Boskey AL, Jepsen KJ. Fourier transform infrared imaging microspectroscopy and tissue-level mechanical testing reveal intraspecies variation in mouse bone mineral and matrix composition. Calcif Tissue Int 2008; 83:342-53. [PMID: 18855037 PMCID: PMC2650490 DOI: 10.1007/s00223-008-9176-8] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2008] [Accepted: 09/05/2008] [Indexed: 11/24/2022]
Abstract
Fracture susceptibility is heritable and dependent upon bone morphology and quality. However, studies of bone quality are typically overshadowed by emphasis on bone geometry and bone mineral density. Given that differences in mineral and matrix composition exist in a variety of species, we hypothesized that genetic variation in bone quality and tissue-level mechanical properties would also exist within species. Sixteen-week-old female A/J, C57BL/6J (B6), and C3H/HeJ (C3H) inbred mouse femora were analyzed using Fourier transform infrared imaging and tissue-level mechanical testing for variation in mineral composition, mineral maturity, collagen cross-link ratio, and tissue-level mechanical properties. A/J femora had an increased mineral-to-matrix ratio compared to B6. The C3H mineral-to-matrix ratio was intermediate of A/J and B6. C3H femora had reduced acid phosphate and carbonate levels and an increased collagen cross-link ratio compared to A/J and B6. Modulus values paralleled mineral-to-matrix values, with A/J femora being the most stiff, B6 being the least stiff, and C3H having intermediate stiffness. In addition, work-to-failure varied among the strains, with the highly mineralized and brittle A/J femora performing the least amount of work-to-failure. Inbred mice are therefore able to differentially modulate the composition of their bone mineral and the maturity of their bone matrix in conjunction with tissue-level mechanical properties. These results suggest that specific combinations of bone quality and morphological traits are genetically regulated such that mechanically functional bones can be constructed in different ways.
Collapse
Affiliation(s)
- Hayden-William Courtland
- Division of Endocrinology, Diabetes, and Bone Diseases, Mount Sinai School of Medicine, New York, NY, USA, e-mail:
| | - Philip Nasser
- Leni & Peter W. May Department of Orthopedics, Mount Sinai School of Medicine, Box 1188, One Gustave Levy Place, New York, NY 10029, USA, e-mail:
| | - Andrew B. Goldstone
- Leni & Peter W. May Department of Orthopedics, Mount Sinai School of Medicine, Box 1188, One Gustave Levy Place, New York, NY 10029, USA, e-mail:
| | - Lyudmila Spevak
- Musculoskeletal Integrity Program, Hospital for Special Surgery, New York, NY, USA, e-mail:
| | - Adele L. Boskey
- Musculoskeletal Integrity Program, Hospital for Special Surgery, New York, NY, USA, e-mail:
| | - Karl J. Jepsen
- Leni & Peter W. May Department of Orthopedics, Mount Sinai School of Medicine, Box 1188, One Gustave Levy Place, New York, NY 10029, USA
| |
Collapse
|
36
|
Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure. J Biomech 2008; 41:2932-9. [PMID: 18786670 DOI: 10.1016/j.jbiomech.2008.07.025] [Citation(s) in RCA: 114] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2008] [Revised: 07/14/2008] [Accepted: 07/27/2008] [Indexed: 11/23/2022]
|
37
|
Boivin G, Bala Y, Doublier A, Farlay D, Ste-Marie LG, Meunier PJ, Delmas PD. The role of mineralization and organic matrix in the microhardness of bone tissue from controls and osteoporotic patients. Bone 2008; 43:532-8. [PMID: 18599391 DOI: 10.1016/j.bone.2008.05.024] [Citation(s) in RCA: 122] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2008] [Revised: 05/27/2008] [Accepted: 05/28/2008] [Indexed: 11/24/2022]
Abstract
Degree of mineralization of bone (DMB) is a major intrinsic determinant of bone strength at the tissue level but its contribution to the microhardness (Vickers indentation) at the intermediary level of organization of bone tissue, i.e., Bone Structural Units (BSUs), has never been assessed. The purpose of this study was to analyze the relationship between the microhardness, the DMB and the organic matrix, measured in BSUs from human iliac bone biopsies. Iliac bone samples from controls and osteoporotic patients (men and women), embedded in methyl methacrylate, were used. Using a Vickers indenter, microhardness (kg/mm2) was measured, either globally on surfaced blocks or focally on 100 microm-thick sections from bone samples (load of 25 g applied during 10 sec; CV=5%). The Vickers indenter was more suited than the Knoop indenter for a tissue like bone in which components are diversely oriented. Quantitative microradiography performed on 100 microm-thick sections, allowed measurement of parameters reflecting the DMB (g/cm3). Assessed on the whole bone sample, both microhardness and DMB were significantly lower (-10% and -7%, respectively) in osteoporotic patients versus controls (p<0.001). When measured separately at the BSU level, there were significant positive correlations between microhardness and DMB in controls (r2=0.36, p<0.0001) and osteoporotic patients (r2=0.43, p<0.0001). Mineralization is an important determinant of the microhardness, but did not explain all of its variance. To highlight the role of the organic matrix in bone quality, microhardness of both osteoid and adjacent calcified matrix were measured in iliac samples from subjects with osteomalacia. Microhardness of organic matrix is 3-fold lower than the microhardness of calcified tissue. In human calcanei, microhardness was significantly correlated with DMB (r2=0.33, p=0.02) and apparent Young's modulus (r2=0.26, p=0.03). In conclusion, bone microhardness measured by Vickers indentation is an interesting methodology for the evaluation of bone strength and its determinants at the BSU level. Bone microhardness is linked to Young's modulus of bone and is strongly correlated to mineralization, but the organic matrix accounts for about one third of its variance.
Collapse
Affiliation(s)
- G Boivin
- INSERM Unité 831, Université de Lyon, Faculté de Médecine R. Laennec, Lyon, France.
| | | | | | | | | | | | | |
Collapse
|
38
|
Allen MR, Burr DB. Mineralization, microdamage, and matrix: How bisphosphonates influence material properties of bone. ACTA ACUST UNITED AC 2007. [DOI: 10.1138/20060248] [Citation(s) in RCA: 60] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
39
|
Dall'Ara E, Ohman C, Baleani M, Viceconti M. The effect of tissue condition and applied load on Vickers hardness of human trabecular bone. J Biomech 2007; 40:3267-70. [PMID: 17599339 DOI: 10.1016/j.jbiomech.2007.04.007] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2007] [Revised: 04/12/2007] [Accepted: 04/13/2007] [Indexed: 10/23/2022]
Abstract
Hardness of trabecular human bone, evaluated by microindentation testing, has generally been measured on embedded tissues. It was known that this was not ideal but it had been preferred to other conditions (e.g. wet or dehydrated) as the trabeculae could withstand the applied load and the measurements were reliable. The aim of this study was to investigate if the tissue condition of the specimen and the applied load would alter the hardness values measured by Vickers microindentation. Vickers hardness values of human trabecular bone from the femoral head, prepared in three different ways (wet, dry and embedded) and tested with two different loads (50 and 25 gf), were measured. No significant difference was found between the two different loads. However, in several cases the 50 gf indentations had to be redone because they were too large or the trabecula broke locally. Even if the outlines of the indentations on wet bone were slightly less marked than the ones done on dehydrated or embedded bone, it was possible to measure the hardness. Significant differences of Vickers hardness values were found between the three preparations: the hardness increased passing from wet to dried (10%) and from wet to embedded (35%). Whereas the variation coefficient of the three tissue conditions were comparable. In conclusion, it is recommended to test human trabecular bone in a wet condition as it better represents the in vivo condition. Furthermore the use of a 25 gf load is suggested, allowing hardness measurements on almost all trabeculae without breaking them.
Collapse
Affiliation(s)
- Enrico Dall'Ara
- Laboratorio di Tecnologia Medica, Istituti Ortopedici Rizzoli, Via di Barbiano, 1/10, 40136 Bologna, Italy
| | | | | | | |
Collapse
|
40
|
Zioupos P. In vivo fatigue microcracks in human bone: Material properties of the surrounding bone matrix. ACTA ACUST UNITED AC 2005; 42:31-41. [PMID: 16123022 DOI: 10.1080/09243860500095463] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Human bones sustain fatigue damage in the form of in vivo microcracks as a result of the normal everyday loading activities. These microcracks appear to preferentially accumulate in certain regions of bone and most notably in interstitial bone matrix areas. These are remnants of old bone tissue left unremodelled, which show a higher than average mineral content and consequently the occurrence of microcracks has been attributed to the possible brittleness brought about by such hypermineralisation. There is a need, therefore, for information on the in situ bone matrix properties in the vicinity of such in vivo microcracks to elucidate the possible causes of their appearance. The present study examined the elastic, strain rate (viscous) and plastic properties of bone matrix in selectively targeted areas by nanoindentation and in both quasistatic and dynamic mode. The results showed that in vivo crack areas are not as stiff as some well-known extremely mineralised and brittle bone examples (bulla, rostrum); the strain rate effects of crack regions were identical to those of other regions of human bone and agreed well with values collected for human bone in the past at the macroscale; while the plasticity index of the crack regions was also not statistically different from most bone examples (including human at random, bovine, bulla and rostrum) except antler, which showed lower plasticity and thus a greater fraction of elastic recovery in indentation energy. It is difficult, therefore, to explain the susceptibility of these interstitial regions to crack in terms of the mineral content and its after-effects on elasticity, viscosity and plasticity alone, but one need to attribute the cracks to the cumulative loading history of these areas, or raise the suggestion that these areas of bone matrix are in some measure 'aged' or material/quality defective.
Collapse
Affiliation(s)
- P Zioupos
- Department of Materials and Medical Sciences, Center for Photo-Manipulation and Photo-Analysis of Materials, Cranfield University, Shrivenham SN 8LA, UK.
| |
Collapse
|
41
|
Misof BM, Roschger P, Baldini T, Raggio CL, Zraick V, Root L, Boskey AL, Klaushofer K, Fratzl P, Camacho NP. Differential effects of alendronate treatment on bone from growing osteogenesis imperfecta and wild-type mouse. Bone 2005; 36:150-8. [PMID: 15664013 DOI: 10.1016/j.bone.2004.10.006] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2004] [Revised: 10/08/2004] [Accepted: 10/12/2004] [Indexed: 01/01/2023]
Abstract
Bisphosphonates have been reported to decrease the number of fractures in children with osteogenesis imperfecta (OI). The current study sought to further explore bisphosphonate-associated bone changes in OI by investigating the effects of alendronate (ALN) treatment on bone mechanical and material properties in osteogenesis imperfecta (oim/oim) and wild-type (+/+) mice treated with 26-73 microg kg(-1) day(-1) of ALN for 8 weeks via subcutaneously implanted pumps. Femoral three-point bend tests to evaluate cortical bone were combined with geometric and material density analysis. Cortical and trabecular architecture of metaphyseal bone were histomorphometrically evaluated and material density assessed by quantitative backscattered electron imaging (qBEI). For the cortical oim/oim bone, which revealed principally inferior biomechanical properties compared to +/+ bone, ALN neither improved cortical strength or any other mechanical property, nor affected cortical width (Ct.Wi.) or material density. In contrast, for the +/+ mice, bone strength was enhanced (+22%, P < 0.05) though coupled with increased brittleness (+28%, P < 0.05). This mechanical improvement was associated with an increase in Ct.Wi. (+17.3%, P = 0.02) and a reduction in heterogeneity of cortical mineralization (Ca(Width), -4%, P = 0.04). In the metaphysis, ALN raised cancellous bone volume (BV/TV) significantly in oim/oim as well as in +/+ mice (+97%, P = 0.008 and +200%, P < 0.0001, respectively). This occurred without any change in either material density or trabecular thickness (Tb.Th.) in the oim/oim mice, while in the +/+ mice, material density increased slightly but significantly (+3%, P = 0.004), and Tb.Th. increased by 77% (P < 0.0001). Taken together, these results illustrate the differential effects of ALN on oim/oim vs. +/+ bone, as well as on specific skeletal sites, i.e., cortical vs. trabecular bone. ALN augmented the mechanical, geometrical, and material properties of +/+ cortical and trabecular bone, while the only observable improvement to the oim/oim bone was increased cancellous bone volume. This suggests that in this mouse model of OI, the previously demonstrated bisphosphonate-associated reduction in fractures is primarily attributable to increased metaphyseal bone mass.
Collapse
Affiliation(s)
- Barbara M Misof
- Ludwig Boltzmann Institute of Osteology at the Hanusch Hospital of WGKK and AUVA Trauma Centre Meidling, 4th Med. Department Hanusch Hospital, Kundratstr, 37, A-1120 Vienna, Austria
| | | | | | | | | | | | | | | | | | | |
Collapse
|
42
|
Currey JD. Tensile yield in compact bone is determined by strain, post-yield behaviour by mineral content. J Biomech 2004; 37:549-56. [PMID: 14996567 DOI: 10.1016/j.jbiomech.2003.08.008] [Citation(s) in RCA: 170] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/06/2003] [Indexed: 11/28/2022]
Abstract
Compact bone specimens from many species were examined to determine the relationships, in tension, between mineral content, Young's modulus, yield stress, yield strain, post-yield stress, post-yield strain, ultimate stress, ultimate strain and work under the stress-strain curve. Yield strain varied much less than the post-yield strain, and yield stress was strongly dependent on Young's modulus. Mineral content was a rather poor predictor of yield stress. However, post-yield events were predicted better by mineral (calcium) content than by Young's modulus. The greater the mineral content the less the post-yield work under the curve and the less the increase in post-yield stress and strain. The findings are compared with those of Les et al. who compressed specimens from equine metacarpals. Where they can be compared, the results are consistent with each other.
Collapse
Affiliation(s)
- John D Currey
- Department of Biology, University of York, York YO10 5YW, UK.
| |
Collapse
|
43
|
The microhardness and fracture surface of the petrodentine of Lepidosiren (Dipnoi), and of other mineralised tissues. Arch Oral Biol 2003; 48:439-47. [PMID: 12749916 DOI: 10.1016/s0003-9969(03)00037-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
The South American lungfish Lepidosiren has toothplates bearing an extremely hard version of dentine: petrodentine. The hardness of this tissue, and its associated ordinary dentine, was compared with that of the enamel, dentine and cement of mammalian teeth, and also with that of other mammalian bony tissues. The hardnesses of petrodentine and dentine of Lepidosiren were found to be similar to those of enamel and dentine in other, mammalian, teeth. Furthermore, the anatomical arrangement of the Lepidosiren tissues was similar to that found in the incisors of rodents, and they presumably function in the same way to keep a sharp chisel edge at the tip of the tooth. Comparison of fracture surfaces of Lepidosiren petrodentine and that of rat incisor showed, however, that petrodentine does not have the refined, crack-stopping structure found in rat incisor enamel.
Collapse
|
44
|
Rogers KD, Daniels P. An X-ray diffraction study of the effects of heat treatment on bone mineral microstructure. Biomaterials 2002; 23:2577-85. [PMID: 12033606 DOI: 10.1016/s0142-9612(01)00395-7] [Citation(s) in RCA: 114] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
A series of human cortical bone specimens has been heated to temperatures up to 1200 degrees C and the mineral content examined in detail by X-ray diffraction. Line profile analysis of the diffraction data has been undertaken to characterise the microstructural (crystallite size and microstrain) features of the mineral at each temperature. Individual profile fitting of several maxima from each diffractogram has also provided precise lattice parameters of the apatite at each temperature. The apatite did not show any significant decomposition over the temperature range although CaO was increasingly formed at temperatures above 600 degrees C. Both finite crystallite size and microstrain contributed significantly to the diffraction peak broadening below 600 degrees C. When heated to > 800 degrees C, the small, rod-like mineral crystallites changed from a highly anisotropically strained state to one with significantly larger equidimensional crystals possessing little microstrain. The findings are discussed in the context of graft bone substitutes and surgical heating of bone.
Collapse
Affiliation(s)
- K D Rogers
- Department of Materials and Medical Sciences, Cranfield University, Swindon, Wiltshire, UK.
| | | |
Collapse
|
45
|
Currey JD, Zioupos P, Davies P, Casino A. Mechanical properties of nacre and highly mineralized bone. Proc Biol Sci 2001; 268:107-11. [PMID: 12123292 PMCID: PMC1087608 DOI: 10.1098/rspb.2000.1337] [Citation(s) in RCA: 91] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
We compared the mechanical properties of 'ordinary' bovine bone, the highly mineralized bone of the rostrum of the whale Mesoplodon densirostris, and mother of pearl (nacre) of the pearl oyster Pinctada margaritifera. The rostrum and the nacre are similar in having very little organic material. However, the rostral bone is much weaker and more brittle than nacre, which in these properties is close to ordinary bone. The ability of nacre to outperform rostral bone is the result of its extremely well-ordered microstructure, with organic material forming a nearly continuous jacket round all the tiny aragonite plates, a design well adapted to produce toughness. In contrast, in the rostrum the organic material, mainly collagen, is poorly organized and discontinuous, allowing the mineral to join up to form, in effect, a brittle stony material.
Collapse
Affiliation(s)
- J D Currey
- Department of Biology, University of York, UK.
| | | | | | | |
Collapse
|