1
|
Kamalasekaran K, Sundramoorthy AK. Applications of chemically modified screen-printed electrodes in food analysis and quality monitoring: a review. RSC Adv 2024; 14:27957-27971. [PMID: 39224631 PMCID: PMC11367709 DOI: 10.1039/d4ra02470b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Accepted: 08/23/2024] [Indexed: 09/04/2024] Open
Abstract
Food analysis and food quality monitoring are vital aspects of the food industry, ensuring the safety and authenticity of various food products, from packaged goods to fast food. In this comprehensive review, we explore the applications of chemically modified Screen-Printed Electrodes (SPEs) in these critical domains. SPEs have become extremely useful devices for ensuring food safety and quality assessment because of their adaptability, affordability, and convenience of use. The Introduction opens the evaluation, that covers a wide spectrum of foods, encompassing packaged, junk food, and food quality concerns. This sets the stage for a detailed exploration of chemically modified SPEs, including their nature, types, utilization, and the advantages they offer in the context of food analysis. Subsequently, the review delves into the multitude applications of SPEs in food analysis, ranging from the detection of microorganisms such as bacteria and fungi, which are significant indicators of food spoilage and safety, to the identification of pesticide residues, food colorants, chemicals, toxins, and antibiotics. Furthermore, chemically modified SPEs have proven to be invaluable in the quantification of metal ions and vitamins in various food matrices, shedding light on nutritional content and quality.
Collapse
Affiliation(s)
- Kavitha Kamalasekaran
- Department of Chemistry, Velammal Engineering College Chennai 600066 Tamil Nadu India
| | - Ashok K Sundramoorthy
- Centre for Nano-Biosensors, Department of Prosthodontics and Materials Science, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences Chennai 600077 Tamil Nadu India
| |
Collapse
|
2
|
Sankar K, Kuzmanović U, Schaus SE, Galagan JE, Grinstaff MW. Strategy, Design, and Fabrication of Electrochemical Biosensors: A Tutorial. ACS Sens 2024; 9:2254-2274. [PMID: 38636962 DOI: 10.1021/acssensors.4c00043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Advanced healthcare requires novel technologies capable of real-time sensing to monitor acute and long-term health. The challenge relies on converting a real-time quantitative biological and chemical signal into a desired measurable output. Given the success in detecting glucose and the commercialization of glucometers, electrochemical biosensors continue to be a mainstay of academic and industrial research activities. Despite the wealth of literature on electrochemical biosensors, reports are often specific to a particular application (e.g., pathogens, cancer markers, glucose, etc.), and most fail to convey the underlying strategy and design, and if it is transferable to detection of a different analyte. Here we present a tutorial review for those entering this research area that summarizes the basic electrochemical techniques utilized as well as discusses the designs and optimization strategies employed to improve sensitivity and maximize signal output.
Collapse
|
3
|
Kalita N, Gogoi S, Minteer SD, Goswami P. Advances in Bioelectrode Design for Developing Electrochemical Biosensors. ACS MEASUREMENT SCIENCE AU 2023; 3:404-433. [PMID: 38145027 PMCID: PMC10740130 DOI: 10.1021/acsmeasuresciau.3c00034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 09/26/2023] [Accepted: 09/27/2023] [Indexed: 12/26/2023]
Abstract
The critical performance factors such as selectivity, sensitivity, operational and storage stability, and response time of electrochemical biosensors are governed mainly by the function of their key component, the bioelectrode. Suitable design and fabrication strategies of the bioelectrode interface are essential for realizing the requisite performance of the biosensors for their practical utility. A multifaceted attempt to achieve this goal is visible from the vast literature exploring effective strategies for preparing, immobilizing, and stabilizing biorecognition elements on the electrode surface and efficient transduction of biochemical signals into electrical ones (i.e., current, voltage, and impedance) through the bioelectrode interface with the aid of advanced materials and techniques. The commercial success of biosensors in modern society is also increasingly influenced by their size (and hence portability), multiplexing capability, and coupling in the interface of the wireless communication technology, which facilitates quick data transfer and linked decision-making processes in real-time in different areas such as healthcare, agriculture, food, and environmental applications. Therefore, fabrication of the bioelectrode involves careful selection and control of several parameters, including biorecognition elements, electrode materials, shape and size of the electrode, detection principles, and various fabrication strategies, including microscale and printing technologies. This review discusses recent trends in bioelectrode designs and fabrications for developing electrochemical biosensors. The discussions have been delineated into the types of biorecognition elements and their immobilization strategies, signal transduction approaches, commonly used advanced materials for electrode fabrication and techniques for fabricating the bioelectrodes, and device integration with modern electronic communication technology for developing electrochemical biosensors of commercial interest.
Collapse
Affiliation(s)
- Nabajyoti Kalita
- Department
of Biosciences and Bioengineering, Indian
Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Sudarshan Gogoi
- Department
of Chemistry, Sadiya College, Chapakhowa, Assam 786157, India
| | - Shelley D. Minteer
- Department
of Chemistry, University of Utah, 315 S 1400 E, Salt Lake City, Utah 84112, United States
- Kummer
Institute Center for Resource Sustainability, Missouri University of Science and Technology, Rolla, Missouri 65409, United States
| | - Pranab Goswami
- Department
of Biosciences and Bioengineering, Indian
Institute of Technology Guwahati, Guwahati, Assam 781039, India
| |
Collapse
|
4
|
Zalke JB, Narkhede NP, Pandhurnekar CP, Rotake DR, Singh SG. Non-enzymatic glucose detection with screen-printed chemiresistive sensor using green synthesised silver nanoparticle and multi-walled carbon nanotubes-zinc oxide nanofibers. NANOTECHNOLOGY 2023; 35:065502. [PMID: 37918017 DOI: 10.1088/1361-6528/ad090c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Accepted: 11/01/2023] [Indexed: 11/04/2023]
Abstract
Non-enzymatic screen-printed chemiresistive interdigitated electrodes (SPCIE) were designed and fabricated using a low-cost screen-printing method for detection of the glucose. The interdigitated electrodes (IDE) pattern was printed using conductive graphene ink on the glossy surface of the photo paper. The proposed glossy photo paper-based SPCIE are functionalized with multi-walled carbon nanotubes-zinc oxide (MWCNTs-ZnO) nanofibers to create the chemiresistive matrix. Further, to bind these nanofibers with the graphene electrode surface, we have used the green synthesized silver nanoparticles (AgNPs) with banana flower stem fluid (BFSF) as a binder solution. AgNPs with BFSF form the conductive porous natural binder layer (CPNBL). It does not allow to increase the resistivity of the deposited material on graphene electrodes and also keeps the nanofibers intact with paper-based SPCIE. The synthesized material of MWCNT-ZnO nanofibers and green synthesized AgNPs with BFSF as a binder were characterized by Ultraviolet-visible spectroscopy (UV-vis), scanning electron microscope (SEM), x-ray diffraction (XRD), and Fourier-transform infrared spectroscopy (FTIR). The amperometric measurements were performed on the proposed SPCIE sensor to detect the glucose sample directly. The innovative paper-based SPCIE glucose sensor exhibits a linear corelation between current measurements and glucose concentration in the range between 45.22μm and 20 mm, with a regression coefficient (R2) of 0.9902 and a lower limit of detection (LoD) of 45.22μm (n= 5). The sensitivity of the developed SPCIE sensor was 2178.57μAmM-1cm-2, and the sensor's response time determined was approximately equal to 18 s. The proposed sensor was also tested for real blood serum sample, and relative standard deviation (RSD) was found equal to 2.95%.
Collapse
Affiliation(s)
- Jitendra B Zalke
- Department of Electronics Design Technology, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - N P Narkhede
- Department of Electronics Engineering, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - C P Pandhurnekar
- Department of Chemistry, Shri Ramdeobaba College of Engineering and Management, Nagpur, India
| | - Dinesh R Rotake
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, India
| | - Shiv Govind Singh
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, India
| |
Collapse
|
5
|
Meskher H, Belhaouari SB, Sharifianjazi F. Mini review about metal organic framework (MOF)-based wearable sensors: Challenges and prospects. Heliyon 2023; 9:e21621. [PMID: 37954292 PMCID: PMC10632523 DOI: 10.1016/j.heliyon.2023.e21621] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 10/05/2023] [Accepted: 10/25/2023] [Indexed: 11/14/2023] Open
Abstract
Among many types of wearable sensors, MOFs-based wearable sensors have recently been explored in both commercialization and research. There has been much effort in various aspects of the development of MOF-based wearable sensors including but not limited to miniaturization, size control, safety, improvements in conformal and flexible features, improvements in the analytical performance and long-term storage of these devices. Recent progress in the design and deployment of MOFs-based wearable sensors are covered in this paper, as are the remaining obstacles and prospects. This work also highlights the enormous potential for synergistic effects of MOFs used in combination with other nanomaterials for healthcare applications and raise attention toward the economic aspect and market diffusion of MOFs-based wearable sensors.
Collapse
Affiliation(s)
- Hicham Meskher
- Division of Process Engineering, College of Science and Technology, Chadli Bendjedid University, 36000, Algeria
| | - Samir Brahim Belhaouari
- Division of Information and Computing Technology, College of Science and Engineering, Hamad Bin Khalifa,Doha, Qatar
| | | |
Collapse
|
6
|
Disposable Electrochemical Biosensor Based on the Inhibition of Alkaline Phosphatase Encapsulated in Acrylamide Hydrogels. BIOSENSORS 2022; 12:bios12090698. [PMID: 36140083 PMCID: PMC9496573 DOI: 10.3390/bios12090698] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/09/2022] [Accepted: 08/26/2022] [Indexed: 11/17/2022]
Abstract
The present work describes the development of an easy-to-use portable electrochemical biosensor based on alkaline phosphatase (ALP) as a recognition element, which has been immobilized in acrylamide-based hydrogels prepared through a green protocol over disposable screen-printed electrodes. To carry out the electrochemical transduction, an electroinactive substrate (hydroquinone diphosphate) was used in the presence of the enzyme and then it was hydrolyzed to an electroactive species (hydroquinone). The activity of the protein within the matrix was determined voltammetrically. Due to the adhesive properties of the hydrogel, this was easily deposited on the surface of the electrodes, greatly increasing the sensitivity of the biosensor. The device was optimized to allow the determination of phosphate ion, a competitive inhibitor of ALP, in aqueous media. Our study provides a proof-of-concept demonstrating the potential use of the developed biosensor for in situ, real-time measurement of water pollutants that act as ALP inhibitors.
Collapse
|
7
|
Barros Azeredo NF, Ferreira Santos MS, Sempionatto JR, Wang J, Angnes L. Screen-Printed Technologies Combined with Flow Analysis Techniques: Moving from Benchtop to Everywhere. Anal Chem 2021; 94:250-268. [PMID: 34851628 DOI: 10.1021/acs.analchem.1c02637] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Screen-printed electrodes (SPEs) coupled with flow systems have been reported in recent decades for an ever-growing number of applications in modern electroanalysis, aiming for portable methodologies. The information acquired through this combination can be attractive for future users with basic knowledge, especially due to the increased measurement throughput, reduction in reagent consumption and minimal waste generation. The trends and possibilities of this set rely on the synergistic behavior that maximizes both SPE and flow analyses characteristics, allowing mass production and automation. This overview addresses an in-depth update about the scope of samples, target analytes, and analytical throughput (injections per hour, limits of detection, linear range, etc.) obtained by coupling injection techniques (FIA, SIA, and BIA) with SPE-based electrochemical detection.
Collapse
Affiliation(s)
- Nathália Florência Barros Azeredo
- Institute of Chemistry, University of São Paulo, São Paulo 05508-070, Brazil.,Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | | | - Juliane R Sempionatto
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Joseph Wang
- Department of Nanoengineering, University of California San Diego, La Jolla, California 92093, United States
| | - Lúcio Angnes
- Institute of Chemistry, University of São Paulo, São Paulo 05508-070, Brazil
| |
Collapse
|
8
|
A Label and Probe-Free Zika Virus Immunosensor Prussian Blue@carbon Nanotube-Based for Amperometric Detection of the NS2B Protein. BIOSENSORS-BASEL 2021; 11:bios11050157. [PMID: 34065688 PMCID: PMC8156682 DOI: 10.3390/bios11050157] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 05/02/2021] [Accepted: 05/10/2021] [Indexed: 12/14/2022]
Abstract
Zika virus (ZIKV) is a mosquito-borne infection, predominant in tropical and subtropical regions causing international concern due to the ZIKV disease having been associated with congenital disabilities, especially microcephaly and other congenital abnormalities in the fetus and newborns. Development of strategies that minimize the devastating impact by monitoring and preventing ZIKV transmission through sexual intercourse, especially in pregnant women, since no vaccine is yet available for the prevention or treatment, is critically important. ZIKV infection is generally asymptomatic and cross-reactivity with dengue virus (DENV) is a global concern. An innovative screen-printed electrode (SPE) was developed for amperometric detection of the non-structural protein (NS2B) of ZIKV by exploring the intrinsic redox catalytic activity of Prussian blue (PB), incorporated into a carbon nanotube–polypyrrole composite. Thus, this immunosensor has the advantage of electrochemical detection without adding any redox-probe solution (probe-less detection), allowing a point-of-care diagnosis. It was responsive to serum samples of only ZIKV positive patients and non-responsive to negative ZIKV patients, even if the sample was DENV positive, indicating a possible differential diagnosis between them by NS2B. All samples used here were confirmed by CDC protocols, and immunosensor responses were also checked in the supernatant of C6/36 and in Vero cell cultures infected with ZIKV.
Collapse
|
9
|
Hannah S, Dobrea A, Lasserre P, Blair EO, Alcorn D, Hoskisson PA, Corrigan DK. Development of a Rapid, Antimicrobial Susceptibility Test for E. coli Based on Low-Cost, Screen-Printed Electrodes. BIOSENSORS-BASEL 2020; 10:bios10110153. [PMID: 33114106 PMCID: PMC7690799 DOI: 10.3390/bios10110153] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 10/20/2020] [Accepted: 10/22/2020] [Indexed: 01/03/2023]
Abstract
Antibiotic resistance has been cited by the World Health Organisation (WHO) as one of the greatest threats to public health. Mitigating the spread of antibiotic resistance requires a multipronged approach with possible interventions including faster diagnostic testing and enhanced antibiotic stewardship. This study employs a low-cost diagnostic sensor test to rapidly pinpoint the correct antibiotic for treatment of infection. The sensor comprises a screen-printed gold electrode, modified with an antibiotic-seeded hydrogel to monitor bacterial growth. Electrochemical growth profiles of the common microorganism, Escherichia coli (E. coli) (ATCC 25922) were measured in the presence and absence of the antibiotic streptomycin. Results show a clear distinction between the E. coli growth profiles depending on whether streptomycin is present, in a timeframe of ≈2.5 h (p < 0.05), significantly quicker than the current gold standard of culture-based antimicrobial susceptibility testing. These results demonstrate a clear pathway to a low cost, phenotypic and reproducible antibiotic susceptibility testing technology for the rapid detection of E. coli within clinically relevant concentration ranges for conditions such as urinary tract infections.
Collapse
Affiliation(s)
- Stuart Hannah
- Department of Biomedical Engineering, University of Strathclyde, 40 George Street, Glasgow G1 1QE, UK; (A.D.); (P.L.); (E.O.B.); (D.K.C.)
- Correspondence:
| | - Alexandra Dobrea
- Department of Biomedical Engineering, University of Strathclyde, 40 George Street, Glasgow G1 1QE, UK; (A.D.); (P.L.); (E.O.B.); (D.K.C.)
| | - Perrine Lasserre
- Department of Biomedical Engineering, University of Strathclyde, 40 George Street, Glasgow G1 1QE, UK; (A.D.); (P.L.); (E.O.B.); (D.K.C.)
| | - Ewen O. Blair
- Department of Biomedical Engineering, University of Strathclyde, 40 George Street, Glasgow G1 1QE, UK; (A.D.); (P.L.); (E.O.B.); (D.K.C.)
| | - David Alcorn
- Division of Anaesthesia, Royal Alexandra Hospital, Corsebar Road, Paisley PA2 9PN, UK;
| | - Paul A. Hoskisson
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, 161 Cathedral Street, Glasgow G4 0RE, UK;
| | - Damion K. Corrigan
- Department of Biomedical Engineering, University of Strathclyde, 40 George Street, Glasgow G1 1QE, UK; (A.D.); (P.L.); (E.O.B.); (D.K.C.)
| |
Collapse
|
10
|
Printed Electrodes in Microfluidic Arrays for Cancer Biomarker Protein Detection. BIOSENSORS-BASEL 2020; 10:bios10090115. [PMID: 32906644 PMCID: PMC7559629 DOI: 10.3390/bios10090115] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 08/27/2020] [Accepted: 09/01/2020] [Indexed: 12/27/2022]
Abstract
Medical diagnostics is trending towards a more personalized future approach in which multiple tests can be digitized into patient records. In cancer diagnostics, patients can be tested for individual protein and genomic biomarkers that detect cancers at very early stages and also be used to monitor cancer progression or remission during therapy. These data can then be incorporated into patient records that could be easily accessed on a cell phone by a health care professional or the patients themselves on demand. Data on protein biomarkers have a large potential to be measured in point-of-care devices, particularly diagnostic panels that could provide a continually updated, personalized record of a disease like cancer. Electrochemical immunoassays have been popular among protein detection methods due to their inherent high sensitivity and ease of coupling with screen-printed and inkjet-printed electrodes. Integrated chips featuring these kinds of electrodes can be built at low cost and designed for ease of automation. Enzyme-linked immunosorbent assay (ELISA) features are adopted in most of these ultrasensitive detection systems, with microfluidics allowing easy manipulation and good fluid dynamics to deliver reagents and detect the desired proteins. Several of these ultrasensitive systems have detected biomarker panels ranging from four to eight proteins, which in many cases when a specific cancer is suspected may be sufficient. However, a grand challenge lies in engineering microfluidic-printed electrode devices for the simultaneous detection of larger protein panels (e.g., 50-100) that could be used to test for many types of cancers, as well as other diseases for truly personalized care.
Collapse
|
11
|
Recent advances and new strategies in Leishmaniasis diagnosis. Appl Microbiol Biotechnol 2020; 104:8105-8116. [PMID: 32845368 DOI: 10.1007/s00253-020-10846-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 08/07/2020] [Accepted: 08/17/2020] [Indexed: 02/07/2023]
Abstract
Leishmaniasis is a set of complex and multifaceted syndromes, with different clinical manifestations, caused by different species of the genus Leishmania spp. that can be characterized by at least four syndromes: visceral leishmaniasis (VL, also known as kala-azar), post-kala-azar dermal leishmaniasis (PKDL), cutaneous leishmaniasis (CL), and mucocutaneous leishmaniasis (MCL). Among the most serious clinical forms, VL stands out, which causes the death of around 59,000 people annually. Fast and accurate diagnosis in VL is essential to reduce the disease's morbidity and mortality. There are a large number of diagnostic tests for leishmaniasis, however they do cross-react with other protozoa and their sensitivity changes according to the clinical form of the disease. Thus, it is essential and necessary to provide a diagnosis that is sufficiently sensitive to detect asymptomatic infected individuals and specific to discriminate individuals with other infectious and parasitic diseases, thus enabling more accurate diagnostic tools than those currently used. In this context, the aim of this review is to summarize the conventional diagnostic tools and point out the new advances and strategies on visceral and cutaneous leishmaniasis diagnosis.
Collapse
|
12
|
Tajik S, Beitollahi H, Dourandish Z, Zhang K, Le QV, Nguyen TP, Kim SY, Shokouhimehr M. Recent Advances in the Electrochemical Sensing of Venlafaxine: An Antidepressant Drug and Environmental Contaminant. SENSORS (BASEL, SWITZERLAND) 2020; 20:E3675. [PMID: 32630056 PMCID: PMC7374504 DOI: 10.3390/s20133675] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Revised: 06/04/2020] [Accepted: 06/16/2020] [Indexed: 01/06/2023]
Abstract
Venlafaxine (VEN), as one of the popular anti-depressants, is widely utilized for the treatment of major depressive disorder, panic disorder, as well as anxiety. This drug influences the chemicals in the brain, which may result in imbalance in depressed individuals. However, venlafaxine and its metabolites are contaminants in water. They have exerted an adverse influence on living organisms through their migration and transformation in various forms of adsorption, photolysis, hydrolysis, and biodegradation followed by the formation of various active compounds in the environment. Hence, it is crucial to determine VEN with low concentrations in high sensitivity, specificity, and reproducibility. Some analytical techniques have been practically designed to quantify VEN. However, electroanalytical procedures have been of interest due to the superior advantages in comparison to conventional techniques, because such methods feature rapidity, simplicity, sensitivity, and affordability. Therefore, this mini-review aims to present the electrochemical determination of VEN with diverse electrodes, such as carbon paste electrodes, glassy carbon electrodes, mercury-based electrodes, screen-printed electrodes, pencil graphite electrodes, and ion-selective electrodes.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 76169-11319, Iran;
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76311-33131, Iran; (H.B.); (Z.D.)
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76311-33131, Iran; (H.B.); (Z.D.)
| | - Kaiqiang Zhang
- Jiangsu Key Laboratory of Advanced Organic Materials, Key Laboratory of Mesoscopic Chemistry of MOE, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China;
| | - Quyet Van Le
- Institute of Research and Development, Duy Tan University, Da Nang 550000, Vietnam
| | - Thang Phan Nguyen
- Laboratory of Advanced Materials Chemistry, Advanced Institute of Materials Science, Ton Duc Thang University, Ho Chi Minh City 700000, Vietnam;
- Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City 700000, Vietnam
| | - Soo Young Kim
- Department of Materials Science and Engineering, Korea University, 145 Anam-ro Seongbuk-gu, Seoul 02841, Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University, Seoul 08826, Korea;
| |
Collapse
|
13
|
Carbonaceous Nanomaterials Employed in the Development of Electrochemical Sensors Based on Screen-Printing Technique—A Review. Catalysts 2020. [DOI: 10.3390/catal10060680] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
This paper aims to revise research on carbonaceous nanomaterials used in developing sensors. In general, nanomaterials are known to be useful in developing high-performance sensors due to their unique physical and chemical properties. Thus, descriptions were made for various structural features, properties, and manner of functionalization of carbon-based nanomaterials used in electrochemical sensors. Of the commonly used technologies in manufacturing electrochemical sensors, the screen-printing technique was described, highlighting the advantages of this type of device. In addition, an analysis was performed in point of the various applications of carbon-based nanomaterial sensors to detect analytes of interest in different sample types.
Collapse
|
14
|
Osaki S, Wakida SI, Saito M, Tamiya E. Towards On-site Determination of Secretory IgA in Artificial Saliva with Gold-Linked Electrochemical Immunoassay (GLEIA) Using Portable Potentiostat and Disposable Printed Electrode. Appl Biochem Biotechnol 2020; 193:1311-1320. [PMID: 32535815 DOI: 10.1007/s12010-020-03332-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 04/23/2020] [Indexed: 11/24/2022]
Abstract
Mental stress is closely connected with our physical and mental wellness. Therefore, stress measurement can contribute to assess our lifestyle and increase our quality of life. In this paper, we detect the secretory immunoglobulin A (sIgA), which is the candidate of salivary stress markers, with original electrochemical immunoassay: gold-linked electrochemical immunoassay (GLEIA). This biosensor is based on a sandwich-type immunosensor and adopts the electrochemical method to detect the reduction peak from Au nanoparticles linked to the secondary antibody. GLEIA is convenient and cost-effective that only requires a low sample volume (10 μL). In addition, the GLEIA show high sensitivity and selectivity. We obtained the linear response to relate the concentration of sIgA (10-300 ng/mL) in D-PBS buffer with the artificial saliva which includes salivary inorganic salt and typically glycoprotein (mucin). Furthermore, we obtained acceptable selectivity in the various solution with salivary proteins such as α-amylase, human serum albumin, immunoglobulin G (IgG), lysozyme, and mucin. In the future, we try to detect the sIgA in real saliva for on-site stress measurement using GLEIA and to integrate the various immunosensors for stress markers in saliva.
Collapse
Affiliation(s)
- Shuto Osaki
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan
| | - Shin-Ichi Wakida
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan.,Graduate School of Human Development and Environment, Kobe University, Kobe, Japan
| | - Masato Saito
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan.,Graduate School of Engineering, Osaka University, Suita, Japan
| | - Eiichi Tamiya
- AIST-Osaka University Advanced Photonics and Biosensing Open Innovation Laboratory, AIST, Suita, Japan. .,Graduate School of Engineering, Osaka University, Suita, Japan.
| |
Collapse
|
15
|
Baldassarre A, Mucci N, Lecca LI, Tomasini E, Parcias-do-Rosario MJ, Pereira CT, Arcangeli G, Oliveira PAB. Biosensors in Occupational Safety and Health Management: A Narrative Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:E2461. [PMID: 32260295 PMCID: PMC7177223 DOI: 10.3390/ijerph17072461] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 03/31/2020] [Accepted: 04/02/2020] [Indexed: 12/20/2022]
Abstract
A sensor is a device used to gather information registered by some biological, physical or chemical change, and then convert the information into a measurable signal. The first biosensor prototype was conceived more than a century ago, in 1906, but a properly defined biosensor was only developed later in 1956. Some of them have reached the commercial stage and are routinely used in environmental and agricultural applications, and especially, in clinical laboratory and industrial analysis, mostly because it is an economical, simple and efficient instrument for the in situ detection of the bioavailability of a broad range of environmental pollutants. We propose a narrative review, that found 32 papers and aims to discuss the possible uses of biosensors, focusing on their use in the area of occupational safety and health (OSH).
Collapse
Affiliation(s)
- Antonio Baldassarre
- Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
| | - Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
| | - Luigi Isaia Lecca
- Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
| | - Emanuela Tomasini
- Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
| | | | - Carolina Tauil Pereira
- Hospital De Clinicas, Serviço de Medicina Ocupacional, Porto Alegre 90035-007, Rio Grande do Sul, Brazil
| | - Giulio Arcangeli
- Department of Experimental and Clinical Medicine, University of Florence, 50134 Florence, Italy
| | | |
Collapse
|
16
|
Single-Use Printed Biosensor for L-Lactate and Its Application in Bioprocess Monitoring. Processes (Basel) 2020. [DOI: 10.3390/pr8030321] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
There is a profound need in bioprocess manufacturing for low-cost single-use sensors that allow timely monitoring of critical product and production attributes. One such opportunity is screen-printed enzyme-based electrochemical sensors, which have the potential to enable low-cost online and/or off-line monitoring of specific parameters in bioprocesses. In this study, such a single-use electrochemical biosensor for lactate monitoring is designed and evaluated. Several aspects of its fabrication and use are addressed, including enzyme immobilization, stability, shelf-life and reproducibility. Applicability of the biosensor to off-line monitoring of bioprocesses was shown by testing in two common industrial bioprocesses in which lactate is a critical quality attribute (Corynebacterium fermentation and mammalian Chinese hamster ovary (CHO) cell cultivation). The specific response to lactate of the screen-printed biosensor was characterized by amperometric measurements. The usability of the sensor at typical industrial culture conditions was favorably evaluated and benchmarked with commonly used standard methods (HPLC and enzymatic kits). The single-use biosensor allowed fast and accurate detection of lactate in prediluted culture media used in industrial practice. The design and fabrication of the biosensor could most likely be adapted to several other critical bioprocess analytes using other specific enzymes. This makes this single-use screen-printed biosensor concept a potentially interesting and versatile tool for further applications in bioprocess monitoring.
Collapse
|
17
|
Moolayadukkam S, Thomas S, Sahoo RC, Lee CH, Lee SU, Matte HSSR. Role of Transition Metals in Layered Double Hydroxides for Differentiating the Oxygen Evolution and Nonenzymatic Glucose Sensing. ACS APPLIED MATERIALS & INTERFACES 2020; 12:6193-6204. [PMID: 31916748 DOI: 10.1021/acsami.9b18186] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Layered double hydroxides (LDH) belong to the class of two-dimensional materials having a wide variety of applications ranging from energy storage to catalysis. Often, these materials when used for nonenzymatic electrochemical glucose sensing tend to be interfering with oxygen evolution reaction (OER), resulting in overestimation of the glucose. Herein, to address this, NiFe-based LDH were selected because of their ability to vary the metal ratios. The synthesized LDH have been characterized using various spectroscopic and microscopic techniques. Among the LDH synthesized, Ni4Fe-LDH have been able to differentiate the glucose oxidation potential and the onset potential of OER with minimum interference. The Ni4Fe-LDH sensor shows a sensitivity of 20.43 μA mM-1 cm-2 in the linear range of 0-4 mM concentrations. To further enhance the sensitivity, composites of reduced graphene oxide (rGO) have been synthesized in situ, and the Ni4Fe/rGO5 composites have shown an increased sensitivity of 176.8 μA mM-1 cm-2 attributed to the charge-transfer interactions. To understand the experimental observations, detailed computational studies have been carried out to study the effect of the electronic structure on the metal ratios of the LDH and its role in differentiating glucose sensing and the oxygen evolution reaction. Along with this, theoretical calculations are also carried out on LDH-graphene composites to study the charge-transfer interactions.
Collapse
Affiliation(s)
- Sreejesh Moolayadukkam
- Energy Materials Laboratory , Centre for Nano and Soft Matter Sciences , Bangalore 560013 , India
| | - Siby Thomas
- Department of Mechanical Engineering , Colorado School of Mines , Golden , Colorado 80401 , United States
| | - Ramesh Chandra Sahoo
- Energy Materials Laboratory , Centre for Nano and Soft Matter Sciences , Bangalore 560013 , India
| | - Chi Ho Lee
- Department of Bionano Technology , Hanyang University , Ansan 15588 , Republic of Korea
| | - Sang Uck Lee
- Department of Bionano Technology , Hanyang University , Ansan 15588 , Republic of Korea
- Department of Chemical and Molecular Engineering , Hanyang University , Ansan 15588 , Republic of Korea
| | - H S S Ramakrishna Matte
- Energy Materials Laboratory , Centre for Nano and Soft Matter Sciences , Bangalore 560013 , India
| |
Collapse
|
18
|
Kamanina OA, Kamanin SS, Kharkova AS, Arlyapov VA. Glucose biosensor based on screen-printed electrode modified with silicone sol-gel conducting matrix containing carbon nanotubes. 3 Biotech 2019; 9:290. [PMID: 31328078 DOI: 10.1007/s13205-019-1818-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Accepted: 06/18/2019] [Indexed: 11/30/2022] Open
Abstract
This research shows that high-performance biosensors can be produced by modification of screen-printed electrodes with enzymes and conducting hydrogel based on sol-gel matrix and single-walled carbon nanotubes. Tetraethoxysilane, dimethyldiethoxysilane and polyvinyl alcohol were used as the sol-gel matrix basis. Modified SWCNT provide direct electron transfer during glucose oxidation, as confirmed by cyclic voltammetry. The developed conducting sol-gel screen-printed electrodes can determine glucose within the concentration range 0.045-1.04 mM. The developed biosensor is not only in pace with its world analogues but even exceeds them by some analytical and metrological properties. The developed conducting sol-gel biosensor was used to measure the concentration of glucose in blood. The test results differed only insignificantly from those received with the help of standard glucose meter.
Collapse
Affiliation(s)
- O A Kamanina
- 1Tula State University, Pr. Lenina 92, Tula, 300012 Russia
| | - S S Kamanin
- ZAO "SPETSPRIBOR", Boldina s. 94, Tula, 300028 Russia
| | - A S Kharkova
- 1Tula State University, Pr. Lenina 92, Tula, 300012 Russia
| | - V A Arlyapov
- 1Tula State University, Pr. Lenina 92, Tula, 300012 Russia
| |
Collapse
|
19
|
Habimana JDD, Ji J, Sun X. Minireview: Trends in Optical-Based Biosensors for Point-Of-Care Bacterial Pathogen Detection for Food Safety and Clinical Diagnostics. ANAL LETT 2018. [DOI: 10.1080/00032719.2018.1458104] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Jean de Dieu Habimana
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
- Department of Food Science and Technology, School of Food Science and Technology, University of Rwanda, Kigali, Rwanda
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science, National Engineering Research Center for Functional Foods, Synergetic Innovation Center of Food Safety, International Joint Laboratory on Food Safety, Jiangnan University, Wuxi, Jiangsu, China
| |
Collapse
|
20
|
Sekine T, Sato J, Takeda Y, Kumaki D, Tokito S. Morphological Behavior of Printed Silver Electrodes with Protective Self-Assembled Monolayers for Electrochemical Migration. ACS APPLIED MATERIALS & INTERFACES 2018; 10:16210-16215. [PMID: 29663795 DOI: 10.1021/acsami.8b02996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We evaluated the electrochemical behaviors and reliability of printed silver (Ag) electrodes prepared from nanoparticle inks with the use of protective self-assembled monolayers (SAMs) under electronic bias conditions. The printed Ag electrodes were fabricated by inkjet printing on a hydrophobic substrate. The SAMs, which acted as barriers to moisture, were prepared by immersing the substrate in a pentafluorobenzenethiol solution at ambient temperature (25 °C). We investigated the electrochemical migration phenomenon using the water drop method, and the results showed that the formation of dendrites connecting the cathode and the anode, which can affect the electrochemical reliability of an electric device, was suppressed in the presence of the SAMs. The time before short circuit occurred was found to depend on the spacing between the electrodes, i.e., 130 s, when the distance between the electrodes was 200 μm in the presence of an SAM. We demonstrated that Ag electrodes treated using the procedure described in this work suppress the occurrence of electrical short circuits caused by Ag dendrite formation and thus their electrochemical properties are substantially improved.
Collapse
Affiliation(s)
- Tomohito Sekine
- Research Center for Organic Electronics (ROEL), Graduate School of Science and Engineering , Yamagata University , Yonezawa , Yamagata 992-8510 , Japan
| | - Jun Sato
- Research Center for Organic Electronics (ROEL), Graduate School of Science and Engineering , Yamagata University , Yonezawa , Yamagata 992-8510 , Japan
| | - Yasunori Takeda
- Research Center for Organic Electronics (ROEL), Graduate School of Science and Engineering , Yamagata University , Yonezawa , Yamagata 992-8510 , Japan
| | - Daisuke Kumaki
- Research Center for Organic Electronics (ROEL), Graduate School of Science and Engineering , Yamagata University , Yonezawa , Yamagata 992-8510 , Japan
| | - Shizuo Tokito
- Research Center for Organic Electronics (ROEL), Graduate School of Science and Engineering , Yamagata University , Yonezawa , Yamagata 992-8510 , Japan
| |
Collapse
|
21
|
Qi H, Yue S, Bi S, Ding C, Song W. Isothermal exponential amplification techniques: From basic principles to applications in electrochemical biosensors. Biosens Bioelectron 2018; 110:207-217. [PMID: 29625328 DOI: 10.1016/j.bios.2018.03.065] [Citation(s) in RCA: 73] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Revised: 03/16/2018] [Accepted: 03/28/2018] [Indexed: 12/12/2022]
Abstract
As a conventional amplification technique, polymerase chain reaction (PCR) has been widely applied to detect a variety of analytes with exponential amplification efficiency. However, the requirement of thermocycling procedures largely limits the application of PCR-based methods. Alternatively, several isothermal amplification techniques have been developed since the early 1990s. In particular, according to the reaction kinetics, isothermal exponential amplification techniques possess higher amplification efficiency and detection sensitivity. The isothermal exponential amplification techniques can be mainly divided into two categories: enzyme-based isothermal exponential amplification and enzyme-free isothermal exponential amplification. Considering the advantages of high sensitivity and selectivity, high signal-to-noise ratio, low cost and rapid response time, exponential amplification electrochemical biosensors have attracted considerable attention. In this review, we introduce the basic principles of isothermal exponential amplification techniques and summarize their applications in electrochemical biosensors during the past five years. We also highlighted the present challenges and further perspectives of isothermal exponential amplification-based electrochemical biosensors.
Collapse
Affiliation(s)
- Hongjie Qi
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China
| | - Shuzhen Yue
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China
| | - Sai Bi
- College of Chemistry and Chemical Engineering, Shandong Demonstration Center for Experimental Chemistry Education, Qingdao University, Qingdao 266071, PR China.
| | - Caifeng Ding
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Weiling Song
- Key Laboratory of Sensor Analysis of Tumor Marker, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| |
Collapse
|
22
|
Rizwan M, Mohd-Naim NF, Ahmed MU. Trends and Advances in Electrochemiluminescence Nanobiosensors. SENSORS (BASEL, SWITZERLAND) 2018; 18:E166. [PMID: 29315277 PMCID: PMC5795924 DOI: 10.3390/s18010166] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 01/03/2018] [Accepted: 01/06/2018] [Indexed: 12/11/2022]
Abstract
The rapid and increasing use of the nanomaterials (NMs), nanostructured materials (NSMs), metal nanoclusters (MNCs) or nanocomposites (NCs) in the development of electrochemiluminescence (ECL) nanobiosensors is a significant area of study for its massive potential in the practical application of nanobiosensor fabrication. Recently, NMs or NSMs (such as AuNPs, AgNPs, Fe₃O₄, CdS QDs, OMCs, graphene, CNTs and fullerenes) or MNCs (such as Au, Ag, and Pt) or NCs of both metallic and non-metallic origin are being employed for various purposes in the construction of biosensors. In this review, we have selected recently published articles (from 2014-2017) on the current development and prospects of label-free or direct ECL nanobiosensors that incorporate NCs, NMs, NSMs or MNCs.
Collapse
Affiliation(s)
- Mohammad Rizwan
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE 1410, Brunei Darussalam.
| | - Noor Faizah Mohd-Naim
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE 1410, Brunei Darussalam.
- Institute of Health Sciences, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE 1410, Brunei Darussalam.
| | - Minhaz Uddin Ahmed
- Biosensors and Biotechnology Laboratory, Chemical Science Programme, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE 1410, Brunei Darussalam.
| |
Collapse
|
23
|
|
24
|
Mahshid SS, Vallée-Bélisle A, Kelley SO. Biomolecular Steric Hindrance Effects Are Enhanced on Nanostructured Microelectrodes. Anal Chem 2017; 89:9751-9757. [DOI: 10.1021/acs.analchem.7b01595] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Affiliation(s)
- Sahar Sadat Mahshid
- Department
of Pharmaceutical Science, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2 Canada
| | | | - Shana O. Kelley
- Department
of Pharmaceutical Science, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Ontario M5S 3M2 Canada
| |
Collapse
|
25
|
Safavieh M, Pandya HJ, Venkataraman M, Thirumalaraju P, Kanakasabapathy MK, Singh A, Prabhakar D, Chug MK, Shafiee H. Rapid Real-Time Antimicrobial Susceptibility Testing with Electrical Sensing on Plastic Microchips with Printed Electrodes. ACS APPLIED MATERIALS & INTERFACES 2017; 9:12832-12840. [PMID: 28291334 PMCID: PMC5695042 DOI: 10.1021/acsami.6b16571] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
Rapid antimicrobial susceptibility testing is important for efficient and timely therapeutic decision making. Due to globally spread bacterial resistance, the efficacy of antibiotics is increasingly being impeded. Conventional antibiotic tests rely on bacterial culture, which is time-consuming and can lead to potentially inappropriate antibiotic prescription and up-front broad range of antibiotic use. There is an urgent need to develop point-of-care platform technologies to rapidly detect pathogens, identify the right antibiotics, and monitor mutations to help adjust therapy. Here, we report a biosensor for rapid (<90 min), real time, and label-free bacteria isolation from whole blood and antibiotic susceptibility testing. Target bacteria are captured on flexible plastic-based microchips with printed electrodes using antibodies (30 min), and its electrical response is monitored in the presence and absence of antibiotics over an hour of incubation time. We evaluated the microchip with Escherichia coli and methicillin-resistant Staphylococcus aureus (MRSA) as clinical models with ampicillin, ciprofloxacin, erythromycin, daptomycin, gentamicin, and methicillin antibiotics. The results are compared with the current standard methods, i.e. bacteria viability and conventional antibiogram assays. The technology presented here has the potential to provide precise and rapid bacteria screening and guidance in clinical therapies by identifying the correct antibiotics for pathogens.
Collapse
Affiliation(s)
- Mohammadali Safavieh
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Hardik J. Pandya
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Maanasa Venkataraman
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Prudhvi Thirumalaraju
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Manoj Kumar Kanakasabapathy
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Anupriya Singh
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Devbalaji Prabhakar
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Manjyot Kaur Chug
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
| | - Hadi Shafiee
- Division of Engineering in Medicine, Brigham and Women’s Hospital—Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115, United States
- Department of Medicine, Harvard Medical School, 25 Shattuck Street, Boston, Massachusetts 02115, United States
| |
Collapse
|
26
|
From market to food plate: Current trusted technology and innovations in halal food analysis. Trends Food Sci Technol 2016. [DOI: 10.1016/j.tifs.2016.10.024] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
27
|
Cordeiro M, Ferreira Carlos F, Pedrosa P, Lopez A, Baptista PV. Gold Nanoparticles for Diagnostics: Advances towards Points of Care. Diagnostics (Basel) 2016; 6:diagnostics6040043. [PMID: 27879660 PMCID: PMC5192518 DOI: 10.3390/diagnostics6040043] [Citation(s) in RCA: 79] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2016] [Revised: 11/13/2016] [Accepted: 11/18/2016] [Indexed: 12/24/2022] Open
Abstract
The remarkable physicochemical properties of gold nanoparticles (AuNPs) have prompted developments in the exploration of biomolecular interactions with AuNP-containing systems, in particular for biomedical applications in diagnostics. These systems show great promise in improving sensitivity, ease of operation and portability. Despite this endeavor, most platforms have yet to reach maturity and make their way into clinics or points of care (POC). Here, we present an overview of emerging and available molecular diagnostics using AuNPs for biomedical sensing that are currently being translated to the clinical setting.
Collapse
Affiliation(s)
- Mílton Cordeiro
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
- Rede de Química e Tecnologia (REQUIMTE), Departamento de Química, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
| | - Fábio Ferreira Carlos
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
| | - Pedro Pedrosa
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
| | - António Lopez
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
| | - Pedro Viana Baptista
- UCIBIO, Departamento de Ciências da Vida, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Campus da Caparica, 2829-516 Caparica, Portugal.
| |
Collapse
|
28
|
Guzman NA, Guzman DE. An emerging micro-scale immuno-analytical diagnostic tool to see the unseen. Holding promise for precision medicine and P4 medicine. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1021:14-29. [DOI: 10.1016/j.jchromb.2015.11.026] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2015] [Revised: 11/15/2015] [Accepted: 11/17/2015] [Indexed: 01/10/2023]
|
29
|
Safavieh M, Kanakasabapathy MK, Tarlan F, Ahmed MU, Zourob M, Asghar W, Shafiee H. Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection. ACS Biomater Sci Eng 2016; 2:278-294. [PMID: 28503658 PMCID: PMC5425166 DOI: 10.1021/acsbiomaterials.5b00449] [Citation(s) in RCA: 111] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Rapid, sensitive, and selective pathogen detection is of paramount importance in infectious disease diagnosis and treatment monitoring. Currently available diagnostic assays based on polymerase chain reaction (PCR) and enzyme-linked immunosorbent assay (ELISA) are time-consuming, complex, and relatively expensive, thus limiting their utility in resource-limited settings. Loop-mediated isothermal amplification (LAMP) technique has been used extensively in the development of rapid and sensitive diagnostic assays for pathogen detection and nucleic acid analysis and hold great promise for revolutionizing point-of-care molecular diagnostics. Here, we review novel LAMP-based lab-on-a-chip (LOC) diagnostic assays developed for pathogen detection over the past several years. We review various LOC platforms based on their design strategies for pathogen detection and discuss LAMP-based platforms still in development and already in the commercial pipeline. This review is intended as a guide to the use of LAMP techniques in LOC platforms for molecular diagnostics and genomic amplifications.
Collapse
Affiliation(s)
- Mohammadali Safavieh
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Manoj K. Kanakasabapathy
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Farhang Tarlan
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| | - Minhaz U. Ahmed
- Biosensors and Biotechnology Laboratory, Faculty of Science, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong, Negara Brunei Darussalam
| | - Mohammed Zourob
- Department of Chemistry, College of Science, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Rd, Riyadh 11533, Saudi Arabia
| | - Waseem Asghar
- Department of Computer Engineering & Electrical Engineering and Computer Science, Florida Atlantic University, 777 Glades Road, Boca Raton, Florida 33431, United States
| | - Hadi Shafiee
- Division of Biomedical Engineering, Division of Renal Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, 65 Lansdowne Street, Cambridge, Massachusetts 02139, United States
| |
Collapse
|
30
|
Lim SA, Ahmed MU. Electrochemical immunosensors and their recent nanomaterial-based signal amplification strategies: a review. RSC Adv 2016. [DOI: 10.1039/c6ra00333h] [Citation(s) in RCA: 121] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
In recent years, tremendous advances have been made in biosensors based on nanoscale electrochemical immunosensors for use in the fields of agriculture, food safety, biomedicine, quality control, and environmental and industrial monitoring.
Collapse
Affiliation(s)
- Syazana Abdullah Lim
- Environmental and Life Sciences Programme
- Faculty of Science
- Universiti Brunei Darussalam
- Gadong
- Brunei Darussalam
| | - Minhaz Uddin Ahmed
- Biosensors and Biotechnology Laboratory
- Chemical Science Programme
- Faculty of Science
- Universiti Brunei Daruusalam
- Gadong
| |
Collapse
|
31
|
Sanjay ST, Fu G, Dou M, Xu F, Liu R, Qi H, Li X. Biomarker detection for disease diagnosis using cost-effective microfluidic platforms. Analyst 2015; 140:7062-81. [PMID: 26171467 PMCID: PMC4604043 DOI: 10.1039/c5an00780a] [Citation(s) in RCA: 157] [Impact Index Per Article: 17.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Early and timely detection of disease biomarkers can prevent the spread of infectious diseases, and drastically decrease the death rate of people suffering from different diseases such as cancer and infectious diseases. Because conventional diagnostic methods have limited application in low-resource settings due to the use of bulky and expensive instrumentation, simple and low-cost point-of-care diagnostic devices for timely and early biomarker diagnosis is the need of the hour, especially in rural areas and developing nations. The microfluidics technology possesses remarkable features for simple, low-cost, and rapid disease diagnosis. There have been significant advances in the development of microfluidic platforms for biomarker detection of diseases. This article reviews recent advances in biomarker detection using cost-effective microfluidic devices for disease diagnosis, with the emphasis on infectious disease and cancer diagnosis in low-resource settings. This review first introduces different microfluidic platforms (e.g. polymer and paper-based microfluidics) used for disease diagnosis, with a brief description of their common fabrication techniques. Then, it highlights various detection strategies for disease biomarker detection using microfluidic platforms, including colorimetric, fluorescence, chemiluminescence, electrochemiluminescence (ECL), and electrochemical detection. Finally, it discusses the current limitations of microfluidic devices for disease biomarker detection and future prospects.
Collapse
Affiliation(s)
- Sharma T Sanjay
- Department of Chemistry, University of Texas at El Paso, 500 West University Ave, El Paso, Texas 79968, USA.
| | | | | | | | | | | | | |
Collapse
|